Main Characteristics
• Controller applicable for ALS1000 (CCR Cabinet)
• Controller compatible to SFU32 / SFL40 connector
• SFL48-IF LED-Inset Flash Light
• Avg. Light Beam >22kcd
• SFL48-EF LED-Elevated Flash Light
• Avg. Light Beam >22kcd
• No additional Cabling required
• No additional electronic in field
• Very high Life Cycle (>10 Years)
• Low Maintenance
Variants
Fig. 1 SFL48 LED-Flash Light
• E900 Approach
• 600 Approach
• Option RETIL
• Only RETIL
• Elevated/Inset Lights
AGL Substation
Low-Voltage- ASL1000
Cabinet Controller SFU48 CMS-System
(Available on site) (Available on site)
Flash
No.31
Flash Flash Flash Flash Flash Flash Flash Flash Flash Flash Flash
No.1 No.2 No.3 No.4 No.5 No.6 No.26 No.27 No.28 No.29 No.30
Flash
No.32
31
900m Approach with SFL
1 5 10 15 20 25 30
32
31
600m Approach with SFL
1 5 10 15 20
32
Runway Edge Identification Lights only
31
32
Honeywell Airports Business Tel.: +49 (0) 40 61144-67 Dok. Nr. 65 880 540-TD
Brödermansweg 1 Fax.: +49 SFL48
Fig. 5 Dimensions (0) 40 6Flash
1144-0Lights
6
22453 Hamburg www.honeywellairports.com
Dimensions Flash-Lights
Isocandela Diagram
Fig. 6 Isocandela Diagram ICAO Annex 14, Add. 2-1, Approach Lights
Technical Data – Light Measurement
ISOCANDELA MEASUREMENT LED-SFL (INSET)
Isocandela Diagram
Fig. 7 Isocandela Diagram ICAO Annex 14, Add. 2-6, Runway Centre Line Light
SFL48 / SFU48 Technical Specifications
TECHNICAL DATA – CONTROL UNIT SFU48 TECHNICAL DATA – FLASH SFL48 (ELEVATED)
Supply Chain: 230 VAC Supply voltage:
Frequency:50 Hz Flash: 230 V / 50 Hz
Power input with maximum configuration: Heating: 230 V / 50 Hz
Power used for flash lights: 905W Ambient temperature: -40°C - +55°C
Power used for heating: 1600W Humidity: 100% at 35°C
Fuses: Protection class: IP 65
Phase 1: 20 A T Dimensions (WxHxD): 326 x 411 x 126 mm
Phase 2: 10 A T Weight approximately: 15 kg
Control Voltages: 24 VDC Light Intensity (Avg.): >20.000 Cd
Output voltage: 230 VAC Vertical setting range :0° – 15°
Ambient temperature: -5°C - +55°C Colour :RAL 1006
Humidity: 95% (no condensation)
Cable diameter input: 5 x 10mm² TECHNICAL DATA – FLASH SFL48 (INSET)
Cable diameter output: Supply voltage:
Up to 1000m complete cable length: NYCWY Flash: 230 V / 50 Hz
4x10RE/10 Ambient temperature: -40°C - +55°C
Up to 2000m complete cable length: NYCWY Humidity: 100% at 35°C
4x16RE/16 Protection class: IP 67
Up to 3000m complete cable length: NYCWY Dimensions (WxHxD): 326 x 411 x 126 mm
4x25RM/16 Weight approximately: 6,7 kg
Sizes of Joint Connections: Light Intensity (Avg.): >5.000 Cd
Power Supply: M40, 15 – 23mm Vertical setting range :3,5°
Communication Line: M25, 6 – 13mm Colour :Aluminium
Main Cable: M50, 22 – 29mm
Rating of back indication contacts:
Voltage/Currency/Power
220VDC/0,24A/60W
125VDC/0,24A/30W
30VDC/2A/60W
250VAC/0,25A/62,5VA
125VAC/0,5A/62,5VA
Protection class: IP 21
Dimensions: 19“, 3HE
Weight approximately: Ca. 5 kg
Colour: RAL 7035
For more information on these and other Honeywell Airport Systems products, visit
http://www.honeywellairports.com