DISTRIBUTION BOARD: (B) (12-Way SPN)

S.No. CIRCUIT WIRE SIZE SP. MCB’s LOCATION


NO. IN RATING
(SQ.MM) (A)
1. B1 2 X 1.5 6 Drawing/Dining , Balcony I
2. B2 2 X 1.5 6 Kitchen, Bedrooms, Toilet &
Balcony II
3. B3 2 X 4 16 Drawing/Dining,

4. B4 2 X 4 16 Kitchen
5. B5 2 X 4 16 Toilet
6. B6 2 X 4 20 Bed Room (AC)

ISOLATOR: 40 A (DP MCB)


LEGEND: (ELECTRICAL)
S.NO SYMBOL DESCRIPTION POSSITION
(MM)
1. Light Point/ wall Bracket 2100

2. Ceiling Light (surface)

3. 1 X 29 Watt Tube Light 2100

4. Mirror Light 2000


5. Chandelier

6. Ceiling Fan

7. Exhaust Fan

8. 5 A Plug point 200

9. 5 A Plug point (BED SIDE) 550

10. 5 A Plug point 1050


11. 5 A Socket Outlet 2150

12. 5/ 15 A Power point 200

13. 5/ 15 A Power Point 1050

14. 15 A Power Point (For Geyser) 1650/ or


As
Specificted
15. 20 A AC Point 200/ or
As
Specificted
16. Call Bell Push 1050

17. Buzzer 2100

18. Distribution Board 1350

19. Switch Board 1050

20. Indicate controlling of Light/ Fan from switch


Board