Sei sulla pagina 1di 20

8 - VIBRATION AND SHOCK MOUNTS I

PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM

R
Metric
0 10
T

Silicone Gel Vibration Dampers Silicone Gel Vibration Dampers Spring and Silicone Gel Vibration
Flanged pg. 8-5 Double-Studded pg. 8-6 Dampers pg. 8-8 1

3
Silicone Gel Vibration Dampers Silicone Gel Sheets Silicone Gel Tape
Bushings pg. 8-9 pg. 8-10 pg. 8-11
4

Silicone Gel Chip


pg. 8-11
Silicone Foam Sheets
pg. 8-12
Cylindrical Mountings to 6 kgf
pg. 8-13
6

8
Cylindrical Mountings to 34 kgf Cylindrical Mountings to 36 kgf Cylindrical Mountings to 48 kgf
pg. 8-14 pg. 8-15 pg. 8-16
9

10

Cylindrical Mountings to 54 kgf


pg. 8-17
Cylindrical Mountings to 64 kgf
pg. 8-18
Cylindrical Mountings to 84 kgf
pg. 8-19
11

12

13
Cylindrical Mountings to 95 kgf Conical Bumpers Ring Mountings
pg. 8-20 pg. 8-21 pg. 8-22
14

15

8-1
M-Style Mountings V-Style Mountings V-Style Mountings A
pg. 8-23 pg. 8-24 pg. 8-24
I 8 - VIBRATION AND SHOCK MOUNTS
PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM

R
Metric
0 10
T

Base Mountings to 10 lbs (4.6 kgf) Base Mountings to 242 lbs (110 kgf) Heavy-Duty Base Mountings
1 pg. 8-26 pg. 8-27 General Purpose pg. 8-28

6 Wheel Leveling Carry Mountings


pg. 8-29
Leveling Carry Mountings
pg. 8-30

10

11

12

13

14

15

8-2
A
ADVANTAGES OF SILICONE VS. RUBBER I
PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM

Figure 1: REBOUND RESILIENCE


R
Metric
No matter what the temperature could be, Silicone Gel
performs more stably than other materials. 0 10
70 T

60
1
50
REBOUND RESILIENCE %

2
40 A10Z61 and A10Z62 Series Silicone
Urethane High Damping Rubber

30
NBR (Rubber) 3
Natural Rubber

20 4
10
5
0
-100 -50 0 50 100 150
(-148) (-58) (+32) (+122) (+212) (+302) 6
TEMPERATURE °C (°F)

7
Figure 2: COMPRESSION SET
Outstanding restoration is available even when Silicone Gel 8
stays compressed.
70

9
60 1. Compress above materials by 25% and leave
compressed for 22 hours in 70°C (158° F).
50 2. Release compression and leave in normal 10
temperature for 30 minutes.
COMPRESSION SET %

40
11
30
12
20

13
10

0 14
A10Z61 Urethane NBR Natural
and High (Rubber) Rubber
A10Z62 Damping
Series Rubber
Silicone 15

8-3
A
I TECHNICAL INFORMATION FOR SILICONE GEL DAMPERS

PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM

R
Metric
0 10
T
General Characteristics A10Z61MA1 A10Z61MA2 & A10Z61MB1 A10Z61MB2 & A10Z61MSF10
Specific Gravity 1.05 1.06 1.07
1 Needle*
Penetration 55 — —
Hardness
(1/10 mm)
Asker C** — 33 52.5
2 Specific Heat
1.52 1.51 1.52
(J/g x K)
Thermal
Conductivity 0.2 0.2 0.2
3 (W/m x K)
Specific Volume
Resistance Ratio 4.0 x 1014 3.2 x 1014 6.6 x 1014
(Ohm x cm)
4 Toluene + + +
Acetone + + +
Methanol - - -
5 Chemical
Distilled H2O
Fuel +
- -
+
-
+
Resistance
Lubricant + + +
NaCI (10%) - - -
6 HCI (10%)
NaOH (5%)
- - -
- - -
Operating -40°C to
-40°C to +200°C -40°C to +200°C
Temperature +200°C
7 + = Has a Reaction
- = No Reaction

8
Catalog Number Quantity of Deflection (mm) Load at Deflection (kgf)

9 A10Z61MTHB
A10Z61MTHA
6.3 +/-1
3.3 +/-1
0.010
0.010
A10Z61MTHC 5 +/-1 0.026
A10Z61MTHTW 4.4 +/-0.5 0.208
10 A10Z61MMN03 3.5 +/-1 0.031
A10Z61MMN05 3.5 +/-1 0.052
A10Z61MMN07 3.5 +/-1 0.073
A10Z61MMN10 3.5 +/-1 0.104
11 A10Z61MSF02 4 +/-0.5 0.031
A10Z61MSF05 4 +/-0.5 0.078
A10Z61MSF10 4 +/-0.5 0.146

12 * JIS K 2207
** Japan Rubber Association Standard (SRIS 0101)

13

14

15

8-4
A
FLANGED SILICONE GEL VIBRATION DAMPERS I
TO BE USED IN COMPRESSION ONLY PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
FOR SMALL TO INTERMEDIATE LOAD APPLICATIONS
DAMPS LOW FREQUENCY VIBRATION
R
CAN BE USED WHEN SPACE IS LIMITED Metric
0 10
 MATERIAL: T
Stud - Steel, Unichro Plated
Body - Silicone Gel
Flange Plate - Stainless Steel
1

60 Ø30 3
46 Ø24 SLOTTED
Ø36 M6
2-4.2x6
LONG HOLE 18 4
60° 22
5
2-R6

METRIC COMPONENT 6
Optimum
Catalog Number Load
kgf/leg 7
A10Z61MSF02 1.25 to 3.25
A10Z61MSF05 3.25 to 7.5
A10Z61MSF10 7.5 to 12.5 8

TYPICAL CHARACTERISTICS OF THE SILICONE MOUNTS


(Example Shown: A10Z61MMN05) 9
100
Load: 20 kgf / 4 Legs Silicone Rubber
31.7
Silicone Dampers
Vibration Level: 0.2G Dampers Dampers 10
Resonance Point 9.5 Hz 19.8 Hz
10 Resonance Magnification 6.5 8.8
11
TRANSMISSIBILITY

3.17 Damping Rubber

1
12
0.315

0.1 13
0.0315

0.01
14
0 20 40 60 80 100

FREQUENCY (Hz)
15

8-5
A
I DOUBLE-STUDDED SILICONE GEL VIBRATION DAMPERS
TO BE USED IN COMPRESSION ONLY PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
FOR SMALL TO INTERMEDIATE LOAD APPLICATIONS
R DAMPS LOW FREQUENCY
Metric
 MATERIAL: 0 10
T Studs - Fig. 1 & 2: Brass, Nickel Plated
Fig. 3: Steel, Unichro Plate
Body - Silicone Gel

1 See application page


for proper usage.

2 M6
Ø20 M6
Ø28

Ø12 17
M4 20
3 15

h h
h
4

5 Ø18 Ø25 Ø35


Fig. 1 Fig. 2 Fig. 3
METRIC COMPONENT
6 Optimum Resonance Resonance Recommended
Fig. Frequency h
Catalog Number Load Point Magnification
No. Hz
mm
kgf/leg Hz dB
7 A10Z61MTHB 1 0.4 to 0.6 13 to 11 13 to 12 18 ~ 18
A10Z61MTHA 1 0.5 to 0.8 16 to 15 12 23 ~ 12
A10Z61MTHC 2 0.8 to 2 14 to 12 13 to 12 20 ~ 18
A10Z61MTHTW 3 12.5 to 25 10 to 8 20 to 19 from 14 25
8
 MATERIAL:
Studs - Steel, Unichro Plate
9 Body - Silicone Gel
M6
See application page
for proper usage. 18
10
22

11

12 Ø24
Ø30
METRIC COMPONENT
13 Optimum Resonance Resonance Recommended
Catalog Number * Load Point Magnification Frequency
kgf/leg Hz dB Hz

14 A10Z61MMN03 2 to 3.5
3.5 to 5.5
12 to 10
11 to 10
12
14 to 13
17 ~
16 ~
**A10Z61MMN05
A10Z61MMN07 5.5 to 8.5 11 to 10 16 to 15 16 ~
A10Z61MMN10 8.5 to 12.5 11 to 10 20 to 18 16 ~
15 * This type is slotted on the stud for fixing a bolt.
** See the next page for Transmissibility Chart.

8-6
A
PROPER APPLICATION OF SILICONE GEL DAMPERS I
 FEATURES: PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
Highest damping effect arises when gel is
compressed 10% up to 30%. R
Low in temperature dependency, this material Metric
offers stable performance from -40°C to +200°C
Excellent chemical resistance.
0 10
Low in compression set. T
Performance stays the same even after
repeated use.
Contains nothing harmful. Environment-friendly.
1
 RIGHT USE:

3
INSTALLED SURFACE
1. EVEN LOAD

7
2. HANG IN COMPRESSIVE DIRECTION

8
 WRONG USE:

3. TWIST
10

1. UNEVEN LOAD 11

12
4. TENSILE
DIRECTION

13

14
2. BOLT HOLE OUT OF CENTER 5. SHEARING
DIRECTION
15

8-7
A
SPRING AND SILICONE GEL VIBRATION DAMPERS I
TO BE USED IN COMPRESSION ONLY PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
DAMPS LOW FREQUENCY VIBRATIONS
VERTICAL VIBRATIONS DAMPED WITHOUT HORIZONTAL DEFLECTION R
Metric
 MATERIAL: 0 10
Studs - Brass T
Body - Silicone Gel
Spring - Piano Wire Type B, Nickel Plated

THREAD
12 3

4
23
SPRING
5

6
Ø15
Ø28
7
METRIC COMPONENT
Optimum Resonance Resonance Recommended
Catalog Number Load Point Magnification Frequency Thread 8
kgf/leg Hz dB Hz
A10Z61MBG7 0.8 to 1.6 16 to 14 M3
A10Z61MBG8 1.5 to 4
10 to 8
18 to 16
from 14
M6 9

10

11
Demonstration of Silicone Gel's outstanding
shock-absorbing abilities.
An ordinary fresh raw egg dropped down from 18 meters high to a 2 cm thick
12
Silicone Gel bed does not break. It is publicly proven many times.

13

14

15

8-08
A
VIBRATION DAMPING SILICONE GEL BUSHINGS I
PROTECTS FRAGILE SUBJECTS FROM PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
MICRO-VIBRATIONS AND LIGHT SHOCKS
R
 MATERIAL: Metric
Collar - Brass 0 10
Bushing - Silicone Gel T
More techincal data is given
on preceding pages.
1

3
d d

4
3.5 3
L 4 4
3 Ø7
Ø11
L 5
Ø4 4 Ø9
Ø7 Ø14
Ø11 Ø5

Fig. 1
Ø9
Ø14 Fig. 2 6

BOLT d
7
(NOT SUPPLIED)
WASHER
(NOT SUPPLIED)
GEL BUSHING
8
OBJECT TO ISOLATE

COLLAR 9
GEL BUSHING 6.5 5
MOUNTING BASE L
5 Ø14
Ø25 10
Ø6
INSTALLATION DIAGRAM
Ø14
Ø25
Fig. 3 11
METRIC COMPONENT

Fig.
d L
Collar Optimum Resonance Resonance Recommended 12
Catalog Number Collar Collar Load Point Magnification Frequency
No.
I.D. Length
Thickness Hz
kgf/leg Hz dB
0.05 to 0.05 kg • 90 ~
A10Z61MS 1 3 6 0.5
0.188
64 to 42 7 to 9
0.188 kg • 60 ~ 13
0.125 to 0.125 kg • 95 ~
A10Z61MA1 2 3 7 1 67 to 35 9 to 10
0.625 0.625 kg • 50 ~
0.625 kg • 70 ~
A10Z61MA2 2 3 7 1 0.625 to 1 49 to 37 15 to 16
1 kg • 55 ~ 14
1 kg • 70 ~
A10Z61MB1 3 4 11 1 1 to 3.75 49 to 23 15 to 17
3.75 kg • 35 ~
A10Z61MB2 3 4 11 1 3.75 to 8 20 to 15 19 to 23
3.75 kg • 30 ~
8 kg • 25 ~
15

8-9
A
I SILICONE GEL SHEETS
LOW RESONANCE MAGNIFICATION PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
OZONE, UV AND CHEMICAL RESISTANT
R SHOCK ABSORBER
REDUCES NOISE Metric
0 10
T  MATERIAL:
Silicone Gel

 INSTALLATION:
1
SUBJECT BOARD

2
GEL SHEET
Divide for light load. Add for heavy load.
3 Make sure of total subject load and then Ø9 Ø10
select optimum gel sheet.

4 Example:
For 0.3 kgf load, add a board for extra weight
or divide A10Z62MSN02 to reduce projections.
100
5 For 10 kgf load, divide A10Z62MSN15 into pieces.

For 80 kgf load, use two of A10Z62MSN50 and


divide if needed.
6
2
7
5 100
8

METRIC COMPONENT
9
Optimum Resonance Resonance Recommended
Catalog Number Load Point Magnification Frequency Deflection Color
mm
kgf/sheet Hz dB Hz
10 A10Z62MSN02 0.5 to 2 27 to 21 6 from 38 1.4 to 3 Yellow
A10Z62MSN05 2 to 5 29 to 23 8 from 40 1.5 to 2.5 Green
A10Z62MSN15 5 to 15 26 to 18 13 from 37 1.1 to 2.2 Orange
11 A10Z62MSN50 15 to 50 22 to 15 20 to 18 from 30 0.7 to 2 Blue

12

13

14

15

8-10
A
SILICONE GEL TAPE & CHIPS I
LOW COMPRESSION SET PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
HIGH WEATHER RESISTANCE
HIGH CHEMICAL RESISTANCE
R
EFFECTIVE IN NARROW SPACE Metric
0 10
 MATERIAL: T
Silicone Gel

 OPERATING TEMPERATURE:
-40°C to +100°C 1

ADHESIVE AGENT ON ONE SIDE


2

W 3

t L 4
Fig. 1

ADHESIVE AGENT
5
ON ONE SIDE

6
L

7
W t

Fig. 2 8

METRIC COMPONENT
9
Catalog Number W L t

Fig. 1 Tape 10
A10Z62MGT1 10 1000 1
A10Z62MGT2 20 1000 1
A10Z62MGT3
A10Z62MGT4
10
20
1000
1000
2
2
11
A10Z62MGT5 10 1000 3
A10Z62MGT6 20 1000 3
Fig. 2 Chips*
A10Z62MGC1 10 10 3
12
A10Z62MGC2 10 10 5
A10Z62MGC3 15 15 3
A10Z62MGC4 15 15 5 13
A10Z62MGC5 15 15 10
A10Z62MGC6 20 20 3
A10Z62MGC7 20 20 5
A10Z62MGC8 20 20 10 14
* Priced per sheet (25 chips per sheet)

15

8-11
A
CYLINDRICAL MOUNTINGS • TO 6 kgf I
FOR COMPRESSION LOADS OF 2 TO 6 kgf PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
SHEAR LOADS OF 1 TO 3 kgf
R
 MATERIAL: Metric
Fastener - Steel, Zinc Plated 0 10
Isolator - Natural Rubber T
 NOTE:
Maximum unthreaded portion of stud
does not exceed 1.59 mm. 1
 LOAD DEFLECTION GRAPHS: L◊ 12.5
Deflections below the line x–x are considered
safe practice for static loads; data above that
2
line are useful for calculating deflections
under dynamic loads.
3
M4 Ø11

6.4 x 3.6
4
C D C
D x
3.2
5.5 x
x
4.5 x
2.7
SHEAR
xx
5
B 2.3 x
LOAD (kgf)

LOAD (kgf)

A
3.6 B
x 1.8 x
A
2.7 x x
1.4 x x 6
1.8 x
0.9 x

0.9
COMPRESSION
0.5
7
0 0.51 1.02 1.52 2.03 2.54 3.05 0 1.27 2.54 3.81 5.08 6.35 7.62
DEFLECTION (mm) DEFLECTION (mm)
8
METRIC COMPONENT
CATALOG NUMBER
A10Z 2M302 M4 9
Load Rating
A, B, C or D
◊ Length, L
07 = 7 mm **
10 = 10 mm 10
Compression Forcing Frequency in Cycles per Minute
Load Maximum Load 1000 1250 1500 1750 2000 2250 2500 2750 3000 3600
Rating kgf Minimum Load for 81% Isolation (kgf)
11
A 2.2 – – – – 1.8 1.4 1.1 0.9 0.8 0.5
B 2.9 – – – – 2.4 1.9 1.5 1.3 1.1 0.7
C 4.7 – – – – 4.5 3.5 2.9 2.4 2 1.2
12
D 6 – – – – 5.9 4.7 3.9 3.2 2.6 1.9

Shear Forcing Frequency in Cycles per Minute 13


Load Maximum Load 1000 1250 1500 1750 2000 2250 2500 2750 3000 3600
Rating kgf Minimum Load for 81% Isolation (kgf)
A 1.2 1.18 0.77 0.54 0.45 0.32 0.22 * * * * 14
B 1.6 – 1.18 0.87 0.63 0.5 0.37 0.32 0.28 * *
C 2.5 – 2.14 1.45 1.13 0.87 0.68 0.59 0.5 0.41 0.32
D 2.9 – 2.76 2 1.54 1.22 1 0.82 0.72 0.63 0.45 15
* At these forcing frequencies, lesser loads will yield less than 81% isolation.
** To be discontinued when present stock is depleted. 8-13
A
I CYLINDRICAL MOUNTINGS • TO 34 kgf
FOR COMPRESSION LOADS OF 18 TO 34 kgf PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
SHEAR LOADS OF 9 TO 19 kgf
R
 MATERIAL: Metric
Fastener - Steel, Zinc Plated 0 10
T Isolator - Natural Rubber

 NOTE:
Maximum unthreaded portion of stud
1 does not exceed 1.59 mm.

12 13.5
 LOAD DEFLECTION GRAPHS:
2 Deflections below the line x–x are considered
safe practice for static loads; data above that
line are useful for calculating deflections
under dynamic loads.
3

M6
4 Ø25

91 36
82 D
5 73
C
32
27
64
COMPRESSION
23
LOAD (kgf)

LOAD (kgf)
54 SHEAR
6 45 18
x
x
x
36
x x B x B
14
x x A
27 A
7 18
x x

x
9
x x
x
9 5 x x

0 0.51 1.02 1.52 2.03 2.54 3.05 0 1.27 2.54 3.81 5.08 6.35 7.62
8 DEFLECTION (mm) DEFLECTION (mm)
METRIC COMPONENT
CATALOG NUMBER
9
A10Z 2M305 M06
Load Rating
A, B, C or D
10
Compression Forcing Frequency in Cycles per Minute
Load Maximum Load 1100 1250 1500 1750 2000 2250 2500 2750 3000 3600
11 Rating kgf Minimum Load for 81% Isolation (kgf)
A 18.2 – – – – 13.8 10.9 8.8 7.3 6.1 4.5
B 19.5 – – – – 17.2 13.6 11.3 9.3 7.9 5.7
12 C 33.6 – – – – 33.6 26.5 21.6 17.9 15 10.7
D 34 – – – – – 30.6 25.2 20.6 17.5 12.5

13 Shear Forcing Frequency in Cycles per Minute


Load Maximum Load 1100 1250 1500 1750 2000 2250 2500 2750 3000 3600
Rating kgf Minimum Load for 81% Isolation (kgf)
14 A 8.6 7.1 5.7 3.8 2.9 * * * * * *
B 9.5 8.6 7 4.8 3.6 2.9 2.3 * * * *
C 16.8 – 14.3 10.2 7.7 6.4 5.2 4.3 * * *
15 D 19 – 18.1 13.3 10 8.4 7.2 5.9 5 4.3 *
* At these forcing frequencies, lesser loads will yield 81% isolation.

8-14
A
CYLINDRICAL MOUNTINGS • TO 36 kgf I
FOR COMPRESSION LOADS OF 15 TO 36 kgf PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
SHEAR LOADS OF 8 TO 18 kgf
R
 MATERIAL: Metric
Fastener - Steel, Zinc Plated 0 10
Isolator - Natural Rubber T
 NOTE:
Maximum unthreaded portion of stud
does not exceed 1.59 mm. 1
12 19
 LOAD DEFLECTION GRAPHS:
Deflections below the line x–x are considered
safe practice for static loads; data above that
2
line are useful for calculating deflections
under dynamic loads.
3

M6 Ø25 4
41 20
x D x D
36 18
x x
x
C 5
32 16
x C x
27 COMPRESSION
14
x SHEAR
LOAD (kgf)

LOAD (kgf)

23
x
B
11 x
B
6
18 x 9 xx
x A A
14 x
7 x

9 5 7
5 2

0 0.51 1.02 1.52 2.03 2.54 3.05 3.56


DEFLECTION (mm)
0 1.27 2.54 3.81 5.08 6.35 7.62 8.89
DEFLECTION (mm)
8
METRIC COMPONENT
CATALOG NUMBER
9
A10Z 2M300 M06
Load Rating
A, B, C or D
10
Compression Forcing Frequency in Cycles per Minute
Load Maximum Load 850 1100 1250 1500 1750 2000 2250 2500 3000 3600
Rating kgf Minimum Load for 81% Isolation (kgf) 11
A 15 – – – 13.2 9.5 7.3 5.7 4.8 3.2 2.3
B 18.1 – – – 17.9 12.9 9.8 7.7 6.4 4.3 3.2
C 27.2 – – – – 22.2 16.8 13.4 10.9 7.7 5.2 12
D 35.9 – – – – 32.9 25 19.7 16.3 11.1 7.7

Shear Forcing Frequency in Cycles per Minute 13


Load Maximum Load 850 1100 1250 1500 1750 2000 2250 2500 3000 3600
Rating kgf Minimum Load for 81% Isolation (kgf)
A 8.2 7.3 4.2 3.3 2.3 1.7 1.3 1 0.8 0.5 * 14
B 9.5 – 5.9 4.6 3.2 2.3 1.8 1.4 1.2 0.8 *
C 15.4 – 11.1 9.1 6.7 5.1 4.1 3.4 2.8 2 1.6
D 18.1 – 14.5 11.8 8.6 6.7 5.5 4.5 3.8 2.7 2.3 15
* At these forcing frequencies, lesser loads will yield 81% isolation.

8-15
A
I CYLINDRICAL MOUNTINGS • TO 48 kgf
FOR COMPRESSION LOADS OF 21 TO 48 kgf PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
SHEAR LOADS OF 12 TO 30 kgf
R
 MATERIAL: Metric
Fastener - Steel, Zinc Plated 0 10
T Isolator - Natural Rubber

 LOAD DEFLECTION GRAPHS:


Deflections below the line x–x are considered
1 safe practice for static loads; data above that
line are useful for calculating deflections
under dynamic loads. 13.5 25

4 M8 Ø35

91 36
D C
5 82 32 x
Dx C
73 x x
B 27
64
COMPRESSION
23 SHEAR
LOAD (kgf)

6 54
LOAD (kgf)
x x B
45 x A
x 18 x
x
36 x
14 x
x
27 A
7 18
x

x
9 x

9 5

8 0 1.27 2.54 3.81 5.08 6.35 7.62 0 2.54 5.08 7.62 10.16 12.7
DEFLECTION (mm) DEFLECTION (mm)
METRIC COMPONENT
CATALOG NUMBER
9
A10Z 2M311 M08
Load Rating
10 A, B, C or D

Compression Forcing Frequency in Cycles per Minute


Load Maximum Load 700 850 1100 1250 1500 1750 2000 2250 2500 3000
11 Rating kgf Minimum Load for 81% Isolation (kgf)
A 21.3 – – – 20.2 13.6 10 8.2 6.1 5 –
B 33.6 – – – 32.9 22 16.1 12.3 9.5 7.9 5.7
12 C 43.5 – – – – 34.3 25.5 19.5 15.4 12.7 8.8
D 47.6 – – – – 45.4 33.1 25.6 20.4 17.2 11.6

Shear
13 Forcing Frequency in Cycles per Minute
Load Maximum Load 700 850 1100 1250 1500 1750 2000 2250 2500 3000
Rating kgf Minimum Load for 81% Isolation (kgf)
14 A 12.3 12.3 8.8 5.2 4.1 2.7 * * * * *
B 18.6 – 14.1 8.6 6.6 4.8 3.6 * * * *
C 29.9 – 24.3 15 12 8.6 6.4 5.2 4.1 * *
15 D 29.9 – 27.7 17.2 13.8 10 8.8 5.9 4.8 3.9 *
* At these forcing frequencies, lesser loads will yield 81% isolation.

8-16
A
CYLINDRICAL MOUNTINGS • TO 54 kgf I
FOR COMPRESSION LOADS OF 19 TO 54 kgf PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
SHEAR LOADS OF 10 TO 29 kgf
R
 MATERIAL: Metric
Fastener - Steel, Zinc Plated 0 10
Isolator - Natural Rubber T
 LOAD DEFLECTION GRAPHS:
Deflections below the line x–x are considered
safe practice for static loads; data above that 1
line are useful for calculating deflections
under dynamic loads. 13.5 32

M8 Ø32 4
6.4 x 3.6
C D C
D
5
x
5.5 3.2
x
x
4.5 2.7 xx
x
SHEAR
B 2.3 x
LOAD (kgf)

LOAD (kgf)

A
3.6
x 1.8 x
B 6
2.7 A
x
x
1.4 x x

1.8
7
x
0.9 x

0.9 0.5
COMPRESSION

0 0.51 1.02 1.52 2.03 2.54 3.05 0 1.27 2.54 3.81 5.08 6.35 7.62
8
DEFLECTION (mm) DEFLECTION (mm)
METRIC COMPONENT
CATALOG NUMBER
A10Z 2M310 M08
9
Load Rating
A, B, C or D
10
Compression Forcing Frequency in Cycles per Minute
Load Maximum Load 600 850 950 1100 1250 1500 1750 2000 2500 3000
Rating kgf Minimum Load for 81% Isolation (kgf) 11
A 18.6 – – – 15.7 12.5 8.6 6.4 4.5 3.2 –
B 29 – – – – 21.8 14.5 10.9 7.9 5.5 3.9
C 40.8 – – – – 36.3 25 18.8 13.6 9.1 6.4 12
D 54.4 – – – – – 40.4 32 24 17.5 12

Shear Forcing Frequency in Cycles per Minute 13


Load Maximum Load 600 850 950 1100 12501750 2000 1500 2500 3000
Rating kgf Minimum Load for 81% Isolation (kgf)
A 9.5 9.1 5 3.9 3 2.5 * * * * * 14
B 14.1 – 8.2 6.4 4.8 3.6 2.5 * * * *
C 21.8 – 14.3 11.3 8.8 7 5 3.9 * * *
D 28.6 – 22.7 18.6 14.8 12.5 9.3 7.3 6.4 3.6 * 15
* At these forcing frequencies, lesser loads will yield 81% isolation.

8-17
A
I CYLINDRICAL MOUNTINGS • TO 64 kgf
FOR COMPRESSION LOADS OF 25 TO 64 kgf PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
SHEAR LOADS OF 15 TO 29 kgf
R
 MATERIAL: Metric
Fastener - Steel, Zinc Plated 0 10
T Isolator - Natural Rubber

 LOAD DEFLECTION GRAPHS:


Deflections below the line x–x are considered
1 safe practice for static loads; data above that
line are useful for calculating deflections
under dynamic loads. 13.5 19

4 M8 Ø32

73 36
x
D
5 64 x 32 x
D
C
C x
54 x 27
x
45 COMPRESSION x
23 SHEAR
LOAD (kgf)

LOAD (kgf)
6 36 x 18
x
x B
B
xx
27 x
x A A
14
x x
7 18 9
9 4

8 0 0.51 1.02 1.52 2.03 2.54 3.05 0 0.25 0.51 0.76 1.02
DEFLECTION (mm) DEFLECTION (mm)
METRIC COMPONENT
CATALOG NUMBER
9
A10Z 2M314 M08
Load Rating
10 A, B, C or D

Compression Forcing Frequency in Cycles per Minute


Load Maximum Load 950 1100 1250 1500 1750 2000 2250 2500 3000 3600
11 Rating kgf Minimum Load for 81% Isolation (kgf)
A 25.4 – – – 22.7 17.2 12.9 10.2 8.2 5.7 –
B 33.1 – – – 33.1 23.1 17.7 13.8 11.1 7.5 5.5
12 C 49.5 – – – – 38.6 28.8 22.7 18.6 12.7 9.1
D 64.4 – – – – 58.5 44.9 35.4 29 20 13.6

13 Shear Forcing Frequency in Cycles per Minute


Load Maximum Load 950 1100 1250 1500 1750 2000 2250 2500 3000 3600
Rating kgf Minimum Load for 81% Isolation (kgf)
14 A 14.5 10.4 8.2 6.6 4.5 3.4 * * * * *
B 17.2 14.5 11.1 8.6 5.9 4.3 3.2 * * * *
C 23.1 – 20.2 16.3 11.8 8.8 6.4 5.5 4.5 * *
15 D 29 – 26.3 21.1 15.4 12.3 9.3 7.7 6.4 4.3 *
* At these forcing frequencies, lesser loads will yield 81% isolation.
8-18
A
CYLINDRICAL MOUNTINGS • TO 84 kgf I
FOR COMPRESSION LOADS OF 42 TO 84 kgf PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
SHEAR LOADS OF 16 TO 30 kgf
R
 MATERIAL: Metric
Fastener - Steel, Zinc Plated 0 10
Isolator - Natural Rubber T
 LOAD DEFLECTION GRAPHS:
Deflections below the line x–x are considered
safe practice for static loads; data above that 1
line are useful for calculating deflections
under dynamic loads. 13.5 16

M8 Ø35 4
91 x
45
D C D
82
x
x 41
C 5
73 36
x B x
64 32
COMPRESSION x SHEAR xx
LOAD (kgf)

LOAD (kgf)

54 27
45 x
x
A
23 x x
B 6
36 x x x A
18
27 14 x

18 9
7
9 4

0 0.25 0.51 0.76 1.02 1.27 1.52 1.78 2.03 2.29 2.54 2.79 0 0.51 1.52 2.54 3.56 4.57 5.08 6.10 7.11 8
DEFLECTION (mm) DEFLECTION (mm)
METRIC COMPONENT
CATALOG NUMBER
9
A10Z 2M312 M08
Load Rating
A, B, C or D 10
Compression Forcing Frequency in Cycles per Minute
Load Maximum Load 950 1100 1250 1500 1750 2000 2250 2500 2750 3000
Rating kgf Minimum Load for 81% Isolation (kgf) 11
A 42.2 – – – – 32.2 23.1 17.7 14.1 11.3 –
B 53.5 – – – – 48.1 36.7 29 23.6 19.5 15.9
C 71.7 – – – – – 54.9 43.5 35.8 29.5 24.5 12
D 83.9 – – – – – 74.4 59.4 49.5 40.8 33.6

Shear Forcing Frequency in Cycles per Minute 13


Load Maximum Load 950 1100 1250 1500 1750 2000 2250 2500 2750 3000
Rating kgf Minimum Load for 81% Isolation (kgf)
A 16.3 15.4 11.3 8.6 6.1 4.5 * * * * * 14
B 20.9 – 17.2 13.6 9.5 7.3 5.5 4.3 * * *
C 25.9 – – 22.7 15.9 11.8 9.1 7.3 5.9 * *
D 30.4 – – 29.9 20.9 15.4 11.8 9.5 8.2 6.4 * 15
* At these forcing frequencies, lesser loads will yield 81% isolation.
8-19
A
I CYLINDRICAL MOUNTINGS • TO 95 kgf
FOR COMPRESSION LOADS OF 43 TO 95 kgf PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM
NOT RECOMMENDED FOR STATIC SHEAR LOADS
R
 MATERIAL: Metric
Fastener - Steel, Zinc Plated 0 10
T Isolator - Natural Rubber

 LOAD DEFLECTION GRAPHS:


Deflections below the line x–x are considered
1 safe practice for static loads; data above that
line are useful for calculating deflections
under dynamic loads.
2 25 13.5

4
M8 M8
Ø38
5
The projections shown are per ISO convention.

6
204
D
181
C
7 159
136 COMPRESSION
LOAD (kgf)

113
x B
8 91 x
x
x A
68 x

x
METRIC COMPONENT 45 x

9 CATALOG NUMBER 23 x

A10Z 2M308 M08 0 1.27 2.54 3.81 5.08 6.35 7.62


Load Rating DEFLECTION (mm)
10 A, B, C or D

Compression Forcing Frequency in Cycles per Minute


11 Load Maximum Load 1150 1250 1500 1750 2000 2750 3500
Rating kgf Minimum Load for 81% Isolation (kgf)
A 43.1 43.1 36.3 25 18.2 13.6 6.8 –
12 B 61.2 – 56.7 38.6 27.2 20.4 10 –
C 83.9 – – 63.5 45.4 34 18.2 11.3
D 95.3 – – 83.9 61.2 47.6 25 15.9
13

14

15

8-20
A
CONICAL BUMPERS I
FOR LOADS OF 20 TO 28 kgf PHONE: 516.328.3300 • FAX: 516.326.8827 • WWW.SDP-SI.COM

 MATERIAL:
R
Fastener - Steel, Zinc Plated Metric
Isolator - Natural Rubber 0 10
T

M8
2

3
Ø25 Ø38

13.5 32
5
The projections shown are per ISO convention.

METRIC COMPONENT
Recommended Maximum Load
7
Catalog Number Static Occasional Dynamic
kgf kgf
A10Z 7M1020AM 20 36.3
8
A10Z 7M1020BM 22.2 45.4
A10Z 7M1020CM 25.4 55.3
A10Z 7M1020DM 28.1 65.8
9

10

11

12

13

14

15

8-21
A

Potrebbero piacerti anche