TCD- 002 Point of ● Run CPU ● DI120~150

Unidentified Alarm Occurrence / Run CPU Address Error Application


TCD- 003 Detection ○ Speed CPU ● DI180~420

[Meaning] ■TCD 2: When un identified codes are read [Symptoms]


by ALARM Interrupt(IR1 of 82C59A) 3 or more consecutive times. 1.Check ALARM LED(LED3) of DOC-200 PCB flickering status.
[When an alarm interrupt occurs without an address error.] ● Normal →OFF
● Abnormal(Address ERROR) →ON
■TCD 3: When unidentified address by address map of
DOC-200 PCB access is detected 3 or more consecutive times. [Actions to take]
1. Check +5[V] voltage.
Must be at least +4.8[V].
[Diagram] TP5 TP6
1) +5[V] : Connector MG/1, MG/6
U1 U7~U10 U25 U26 U28
2) GND : TP16(Located just above Connector MG)
INTR INTR TP8
DATA Data Data
CPU PIC
INTA# Transceiver Transceiver INTA# Transceiver
IR1

LAD[0..31] D[0..31]
(NOT) 19
18 2. As to TCD 2, GAL(U30), 82C59A(U26), or EPLD(U11) of
ID[0..7] D[0..7]

(Programmable
DOC-200 PCB may be failed.
Interrupt
Controller) : Replace GAL first. If TCD 2 error still exists, replace EPLD.
80960KB 74F245 74F640 82C59A 74F245
* Be careful not to damage socket during EPLD
U3~U6 U11 U30 replacement.(Be careful for electrostatics.)
ADDRESS EPLD Alarm
LATCH Logic E-CODE0#
LAD[0..4] 19

D
A[19..20] Bus Control
ADDR-ERR#
2 3. As to TCD 3, DOC-200 PCB FLASH MEMORY(U12, U13) or
Q
G A[28..31]
Logic(BCL)
GAL
14
ALM-INT inside program of the FLASH MEMORY may be failed.
Replace FLASH MEMORY.
74F573 EPM7128ELC84 GAL16V8B

Alarm Interrupt * Be careful not to damage or bend pins while replacing


read_alarm_code() FLASH MEMORY.(Be careful for electrostatics.)
4. If TCD 2 or 3 error exists even after above actions
SIS_ADDR_ERROR ERR_ADDR(TCD 3)
have been taken, replace DOC-200 PCB.
system_down()

Count >= 3
INC
Count

usr_reboot()

TCD 2
Undefined_Alarm_Count >3
TCD 3

INC
Undefined_Alarm_Count