Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Reference Guide
The XP-8v provides superior quality and reliability as well as these features:
• Powerful 1GHz internal processor.
• 4Gb of non-volatile flash memory.
• One HDMI output for on screen display (OSD) video interface
• Eight multi-purpose I/O ports.
• Eight programmable relay outputs.
• Eight two-way RS-232 ports.
• Eight sense inputs.
• Multi-purpose I/O ports are compatible with industry-standard IR emitters, blasters and repeater systems.
• Multi-purpose I/O ports support all optional RTI power sensing and communications modules.
• All output ports incorporate both short-circuit and overload protection.
• Variable IR output on all ports.
• Front panel controls/display (11 Buttons for front panel control).
• Non-volatile Flash memory stores your system configuration even when power is not present.
• Field upgradeable firmware.
• USB and Ethernet programming.
• Compatible with RTI 433MHz and 2.4GHz Zigbee® RF modules.
• Astronomical clock built in for time-based event programming.
• Designed for rack mount or free standing installations.
Touchscreen Control Panel
HIGH OUT
12VDC
INPUT
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 VIDEO OUT POWER
GND
The multi-purpose I/O ports on the XP-8v are compatible with industry
A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B +
5 6 7 8 standard infrared emitters and infrared repeating systems. Each output port is USB EXPANSION +12VDC,1A
capable of driving up to four infrared emitters directly. The use of more than
four infrared emitters requires the addition of an amplified connecting block. A
connecting block can be wired up to 1000 feet away from the XP-8v using #22
IR Connecting Block AWG (minimum) wire.
Each IR output can drive up to INFRARED OUTPUT GAIN ADJUSTMENT
four emitters directly. More than
four emitters require an amplified
The IR output gain can be separately adjusted for each of the eight output
connecting block. ports. The XP-8v is shipped with the IR gain set to the optimum level for most
equipment, and it should only need to be adjusted if the attached equipment is
XP-8v Dimensions
not responding reliably. If adjustment is needed, rotate the IR output controls
on the front of the XP-8v clockwise for higher output power, or counter-
Direct to IR Port clockwise for lower output power.
REMOTE TECHNOLOGIES INC. NOTE: The IR output feedback LEDs located on the front of the XP-8v will
SHAKOPEE, MN 55379 illuminate when any IR code is delivered out of a port. This includes IR codes
Single or Dual “passing through” from another source, such as an IR receiver.
IR Emitters VPS-1 SENSOR MODULE
The multi-purpose I/O ports on the XP-8v are compatible with RTI power
sensing modules (e.g. VPS-1). Follow the guide included with the modules
Voltage From for installation instructions, and follow the instructions in the Integration
Power Supply
Designer® software for programming details.
IR Emitter RS-232 COMMUNICATION MODULES (CM-232)
The multi-purpose I/O ports on the XP-8v are compatible with RTI RS-232
Equipment with switched outlet
or voltage trigger output communication modules (e.g. CM-232). Follow the guide included with
the modules for installation instructions, and follow the instructions in the
CM-232 Communication Module
Integration Designer® software for programming details.
(RS-232 One-way)
RS-232 PORTS The XP-8v is capable of two-way control using RS-232 communication via eight RJ-45
RS-232
output ports using standard Cat-5 cable with RJ-45 termination (568B). The XP-8v ships
ETHERNET
MULTI-PURPOSE I/O PORTS
VOLTAGE / CLOSURE
RELAY / TRIGGER OUTPUTS
A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B +
5 6 7 8
depending on baud rate. USB EXPANSION +12VDC,1A
XP-8v Dimensions
HVAC 5 RXD Receive Data 5 GND Signal Ground
6 TXD Transmit Data 6 DSR Data Set Ready
7 CTS Clear To Send 7 RTS Request To Send
8 RTS Request To Send 8 CTS Clear To Send
Lighting
9 NC Not Connected
REMOTE TECHNOLOGIES INC.
SHAKOPEE, MN 55379
SENSE INPUTS / RELAY-TRIGGER OUTPUTS
SENSE INPUT
Sense inputs and relay-trigger modes are configured within Integration Upon sensing contact closure or a voltage (2-24VDC), events can be
Designer®. automatically triggered such as a macro or command.
S ense contact closure: Connect conductors from the source device
ETHERNET
2
RS-232
3 4 SENSE INPUTS RELAY / TRIGGER OUTPUTS INFRARED RTI COMto each side of a sense input (A and B).
VOLTAGE / CLOSURE 3A @ 30VDC MAX EA. RELAY / 100mA MAX EA. TRIGGER OUTPUT Sense voltage trigger: Connect positive lead from voltage source to
HIGH OUT
Side VIDEO
A ofOUT
sense input and ground lead to Side B.
12VDC
INPUT
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 POWER
GND
A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B +
RELAYS/TRIGGER OUTPUTS
6 7 8 USB
Relays
EXPANSION
may be configured
+12VDC,1A
as a dry contact closure or a voltage trigger
PDM-1 output (12VDC @100mA). All relays are Normally Open when not
Doorbell Rear - Front
+ -+ - energized, and may be programmed to behave Normally Closed (as long
+ - as power is applied to the XP-8v).
TO DOORBELLS
#2
PDM-1
Phone Doorbell Module
PDM1
#1
C
ontact closure: Connect the A and B contact terminals of a relay
Phone Doorbell Module
P/N 20-210126-14
+ -
Model
TO TEL
To
117 612 914
Mute
S/N
Made in Taiwan
to the device.
PDM1/01
Shades V
oltage trigger: Connect contact A to the positive lead and connect
Doorbell Receiver
Phone Contact B to the ground lead of the device.
Service Screen Lift
(POTS)
It’s Under Control®
TERMINAL: +12VDC
RS-232 ETHERNET
1 2 3 4 SENSE INPUTS RELAY / TRIGGER OUTPUTS INFRARED RTI COM
VOLTAGE / CLOSURE 3A @ 30VDC MAX EA. RELAY / 100mA MAX EA. TRIGGER OUTPUT
HIGH OUT
Positive power supply connection. It is internally tied to the Power jack. This can be
12VDC
INPUT
8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 VIDEO OUT POWER
GND
A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B +
XP-8v Dimensions
Systems, etc. High current (200mA) IR output connection. This can be used to power up to 10
infrared mini-emitters, an IR blaster, or extending IR control over a long distance
RF or IR Receivers (1000 ft. max).
REMOTE TECHNOLOGIES INC.
SHAKOPEE, MN 55379
ETHERNET, USB, RTI COM, EXPANSION PORT
ETHERNET
This RJ-45 port allows connection to a 10/100 Base-T Ethernet network (LAN).
ZM-24 Zigbee Network settings such as the IP address are configurable within Integration Designer®.
LAN Transceiver Ethernet may also be used to download system files to the XP-8v.
USB PORTS (REAR)
These host ports for external devices are intended for future use.
RTI COM
RS-232 ETHERNET
2 3 4 SENSE INPUTS
VOLTAGE / CLOSURE
RELAY / TRIGGER OUTPUTS
communication with compatible RTI handheld controllers. Refer to the ZM-24 Zigbee
INPUT
A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B +
XP-8v Dimensions
HDMI, POWER
REMOTE TECHNOLOGIES INC.
SHAKOPEE, MN 55379 6.000
HDMI
1 2
RS-232
3 4 SENSE INPUTS RELAY / TRIGGER OUTPUTS INFRARED
ETHERNET
RTI COM The XP-8v HDMI video output may be connected to an HD display or matrix switch
VOLTAGE / CLOSURE 3A @ 30VDC MAX EA. RELAY / 100mA MAX EA. TRIGGER OUTPUT
INPUT
+
and used in conjunction with RTI user interfaces, the OSD interface provides a visual
A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B
TV Power
Supply
2.14
EXIT PORT 5 PORT 7 PORT 8
PORT 1 PORT 2 PORT 3 PORT 4 PORT 6
Model XP-8v
RESET BACKLIGHT Advanced Control Processor IR OUTPUT ADJUST 5
1.72
Exit
Backlight On/Off Select Cursor Rack
Mount
USB MEMORY EXP. MENU
Reset
PROG. SEL
PORT SD CARD
2.14
EXIT PORT 5 PORT 7 PORT 8
PORT 1 PORT 2 PORT 3 PORT 4 PORT 6
Option
Model XP-8v
RESET BACKLIGHT Advanced Control Processor IR OUTPUT ADJUST
70-210126-19 V1.0
It’s Under Control®
Copyright © 2017 • Remote Technologies Incorporated • All rights reserved. 70-210165-22 V1.0