MULTIPLE CHOICE QUESTIONS FOR CHAPTER 19

All questions have only one correct answer

1. A network designed to pass signals with all frequencies except those between two specified
cut-off frequencies is called a:
[a] low-pass filter
[b] high-pass filter
[c] band-pass filter
[d] band-stop filter

2. A network designed to pass signals at frequencies above a specified cut-off frequency is


called a:
[a] low-pass filter
[b] high-pass filter
[c] band-pass filter
[d] band-stop filter

3. A network designed to pass signals at frequencies below a specified cut-off frequency is


called a:
[a] low-pass filter
[b] high-pass filter
[c] band-pass filter
[d] band-stop filter

4. A network designed to pass signals with frequencies between two specified cut-off
frequencies is called a:
[a] low-pass filter
[b] high-pass filter
[c] band-pass filter
[d] band-stop filter

5. A low-pass T-connected symmetrical filter section has an inductance of 200 mH in each of its
series arms and a capacitance of 0.5 µF in its shunt arm. The cut off frequency of the filter
is:
[a] 1007 Hz
[b] 251.6 Hz
[c] 711.8 Hz
[d] 177.9 Hz

6. A low-pass π-connected symmetrical filter section has an inductance of 200 mH in its series
arm and capacitances of 400 pF in each of its shunt arms. The cut-off frequency of the filter
is:
[a] 25.16 kHz
[b] 6.29 kHz
[c] 17.79 kHz
[d] 35.59 kHz

7. A filter section is to have a nominal impedance of 620 Ω and a cut-off frequency of 2 MHz. A
low pass T-connected symmetrical filter section is comprised of:
[a] 96.68 µH in each series arm, 128.4 pF in shunt arm
[b] 49.34 µH in each series arm, 256.7 pF in shunt arm
[c] 98.68 µH in each series arm, 256.7 pF in shunt arm
[d] 49.34 µH in each series arm, 128.4 pF in shunt arm

8. A filter section is to have a nominal impedance of 620 Ω and a cut-off frequency of 2 MHz. A
low-pass π-connected symmetrical filter section is comprised of:
[a] 98.68 µH in each series arm, 128.4 pF in shunt arm
[b] 49.34 µH in each series arm, 256.7 pF in shunt arm
[c] 98.68 µH in each series arm, 256.7 pF in shunt arm
[d] 49.34 µH in each series arm, 128.4 pF in shunt arm

9. A high-pass T-connected symmetrical filter section has capacitances of 400 nF in each of its
series arms and an inductance of 200 mH in its shunt arm. The cut-off frequency of the filter
is:
[a] 1592 Hz
[b] 1125 Hz
[c] 281 Hz
[d] 398 Hz

10. A high-pass π-connected symmetrical filter section has a capacitance of 5000 pFin its series
arm and inductances of 500 µH in each of its shunt arms. The cut off frequency of the filter
is:
[a] 201.3 kHz
[b] 71.18 kHz
[c] 50.33 kHz
[d] 284.7 kHz

11. A filter section is required to pass all frequencies above 50 kHz and to have a nominal
impedence of 650 Ω. A high-pass T-connected symmetrical filter section is comprised of:
[a] Each series arm 2.45 nF, shunt arm 1.03 mH
[b] Each series arm 4.90 nF, shunt arm 2.08 mH
[c] Each series arm 2.45 nF, shunt arm 2.08 mH
[d] Each series arm 4.90 nF, shunt arm 1.03 mH

12. A filter section is required to pass all frequencies above 50 kHz and to have a nominal
impedence of 650 Ω. A high-pass π-connected symmetrical filter section is comprised of:
[a] series arm 4.90 nF, and each shunt arm 1.04 mH
[b] Series arm 4.90 nF, and each shunt arm 2.07 mH
[c] Series arm 2.45 nF, and each shunt arm 2.07 mH
[d] Series arm 2.45 nF, and each shunt arm 1.04 mH