Abstract - Indian industries majorly include biomedical, computer programming IDE (Integrated Development
agricultural and pharmaceutical which are the pillars of Environment).
country economy. The monitoring of temperature and
humidity are major areas for all these industries. Any kind of
unbalancing in the environmental conditions or unset
parameters can create financial loss in the productivity of
pharmaceutical and agriculture industries. Monitoring of
temperature and humidity are also required for biomedical
industry for drugs and cell culture methods. In healthcare
sectors, environment controlled conditions are also required
for patients threatening. In this paper we are going to
measure temperature and humidity by using Arduino tool and
DHT11, which will be beneficial for balancing the environment
to increase the productivity. Fig-1: Arduino Circuit
© 2018, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 876
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 05 Issue: 12 | Dec 2018 www.irjet.net p-ISSN: 2395-0072
© 2018, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 877
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 05 Issue: 12 | Dec 2018 www.irjet.net p-ISSN: 2395-0072
arranging of sending data. When data bus is at low voltage the environmental factors. From the above all analysis, it is
level it means that DHT11 is sending response signal. Once it ensured that the nested wired systems can be replaced by
is done, DHT again makes data line pull-up for 80µs for the wireless sensor networks to get an accurate data as well
preparing data transmission. Data format that is sending by as to avoid many hazardous issues.
DHT to Arduino for every bit begins with 50µs low voltage
level and length of high voltage level signal determines REFERENCES
whether data bit is “0” or “1”. One important thing is to make
sure pull up resistor value because if we are placing DHT [1] N. H. A. Aziz, W. N. W. Muhamad, N. A. Wahab, A. J. Alias,
sensor at <20 meter distance,5k pullup resistor is A. T. Hashim, and R. Mustafa, "Real time monitoring critical
recommended. If placing DHT at longer the 20 meter then parameters in tissue culture growth room with SMS alert
use appropriate value pull up resistor. system," in Intelligent Systems, Modelling and Simulation
(ISMS), 2010 International Conference on, 2010, pp. 339-
343.
[7]http://www.ardumotive.com/iot-wifi-temp-and-
humidity.html
7. CONCLUSION
© 2018, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 878