Sei sulla pagina 1di 8

24531 Page 94 Thursday, October 25, 2001 6:02 PM

Dimensions TeSys contactors


Model d contactors
Control circuit: a.c.

LC1-D09…D18 (3-pole) LC1-D25…D38 (3-pole)


LC1-DT20…DT60 (4-pole) 44
44
Minimum electrical
Minimum electrical clearance LA4
clearance LA4

b1
b1

b
b

10 c 12,5 45 10 c 12,5 45
2 c1 (LAD-8) c1 (LAD-8)
c2 c2
c3 c3

LC1- D09… D093… D099… D25… D253 DT20 DT203 DT32… DT323
D18 D183 D189 D38 & D323 & DT25 & DT253 DT60 & DT603
b without add-on blocks 77 99 80 85 99 85 99 91 105
b1 with LAD-4BB 94 107 95.5 98 107 98 – – –
with LA4-Dp2 110 (1) 123 (1) 111.5 (1) 114 (1) 123 (1) 114 – – –
with LA4-DF, DT 119 (1) 132 (1) 120.5 (1) 123 (1) 132 (1) 129 – – –
with LA4-DR, DW, DL 126 (1) 139 (1) 127.5 (1) 130 (1) 139 (1) 190 – – –
c without cover or add-on blocks 84 84 84 90 90 90 90 98 98
with cover, without add-on blocks 86 86 86 92 92 92 92 100 100
c1 with LAD-N or C (2 or 4 contacts) 117 117 117 123 123 123 123 131 131
2.3 c2 with LA6-DK10, LAD-6K10 129 129 129 135 135 135 135 143 143
c3 with LAD-T, R, S 137 137 137 143 143 143 143 151 151
with LAD-T, R, S and sealing cover 141 141 141 147 147 147 147 155 155
(1) Including LAD-4BB
LC1-D40…D65 (3-pole) LC1-D80 and D95 (3-pole)
LC1-D65004, D40008 and D65008 (4-pole) 32 44 LC1-D80004 and D80008 (4-pole) 32 44

Minimum electrical Minimum electrical


clearance LA4 clearance LA4

b1
b1

127
127

12 c 12,5 a 12,5 12 c 12,5 a 12,5


c1 (LAD-8) (LAD-8) c1 (LAD-8) (LAD-8)
c2 c2
c3 c3

LC1- D40…D65 D40008 D80 D95 D80004 D80008


D65004 D65008
a 75 85 85 85 96 96
b1 with LA4-Dp2 135 135 135 135 135 135
with LA4-DB3 – – 135 – – –
with LA4-DF, DT 142 142 142 142 142 142
with LA4-DM, DR, DW, DL 150 150 150 150 150 150
c without cover or add-on blocks 114 125 125 125 125 140
with cover, without add-on blocks 119 – 130 130 – –
c1 with LAD-N (1 contact) 139 139 150 150 150 150
with LAD-N or C (2 or 4 contacts) 147 147 158 158 158 158
c2 with LA6-DK 159 159 170 170 170 170
c3 with LAD-T, R, S 167 167 178 178 178 178
with LAD-T, R, S and sealing cover 171 171 182 182 182 182
LC1-D115 and D150 (3-pole)
LC1-D115004 (4-pole) Minimum electrical LAD-8
clearance LA4
LC1- D115 D115004 D115006 D150006 D1150046
D150 10
a 120 150 120 120 155
b1

b1 with LA4-DA2 174 174 174 174 174


158

with LA4-DF, DT 185 185 185 185 185


with LA4-DM, DR, DL 188 188 188 188 188
with LA4-DW 188 188 188 – 188
c without cover or add-on blocks 132 132 115 115 115
with cover, without add-on blocks 136 – – – –
c1 with LAD-N or C (2 or 4 contacts) 150 150 150 150 150 c a
c2 with LA6-DK20 155 155 155 155 155 c1
c3 with LAD-T, R, S 168 168 168 168 168 c2
with LAD-T, R, S and sealing cover 172 172 172 172 172 c3

Selection: Characteristics: References: Schemes:


pages 1/12 to 1/35 pages 2/62 to 2/67 pages 2/74 to 2/77 pages 2/98 and 2/99
2/94 Schneider Electric
LC1-D09…D18 (3-pole) LC1-D25…D38 (3-pole)
b

b
10 c 45
10 c 45
c1
c2
c1
c2
2
c3
c3

LC1- D09…D18 D093…D183 D099…D189 D25…D38 D253 & D323


b 77 99 80 85 99
c without cover or add-on blocks 93 93 93 99 99
with cover, without add-on blocks 95 95 95 101 101
c1 with LAD-N or C (2 or 4 contacts) 126 126 126 132 132
c2 with LA6-DK10 138 138 138 144 144
c3 with LAD-T, R, S 146 146 146 152 152
with LAD-T, R, S and sealing cover 150 150 150 156 156

LC1-DT20 to DT60 (4-pole)

2.3

LC1- DT20 & DT25 DT203 & DT253 DT32…DT60 DT323 & DT403
D098 & D128 D0983 & D1283 D188…D328 D1883 & D2583
b 85 99 91 105
c with cover 90 90 98 98
c1 with LAD-N or C (2 or 4 contacts) 123 123 131 131
c2 with LA6-DK10 135 135 143 143
c3 with LAD-T, R, S 143 143 151 151
with LAD-T, R, S and sealing cover 147 147 155 155

LC1-D40…D65 (3-pole) LC1-D80 and D95 (3-pole)


LP1-D65004, LP1-D40008…D65008 (4-pole) LP1-D80004, LP1-D80008 (4-pole)

LC1- LP1-D65004 LP1-D40008 LC1- LP1- LP1-


D40…D65 & D65008 D80 & D95 D80004 D80008
c without cover or add-on blocks 171 171 182 181 181 196
with cover, without add-on blocks 176 – – 186 – –
c1 with LAD-N (1 contact) 196 196 196 204 204 204
with LAD-N or C (2 or 4 contacts) 202 202 202 210 210 210
c2 with LA6-DK10 213 213 213 221 221 221
c3 with LAD-T, R, S 221 221 221 229 229 229
with LAD-T, R, S and sealing cover 225 225 225 233 233 233
LC1-D115004: see page 2/94.

Schneider Electric 2/95


24531 Page 96 Thursday, October 25, 2001 6:02 PM

Mounting TeSys contactors


Model d contactors

On mounting rail AM1-DP200, DR200 or AM1-DE200 (width 35 mm) On mounting rail AM1-DL200 or DL201 (width 75 mm)
LC1-D09…D38, DT20…DT60 On mounting rail AM1-EDppp or AM1-DE200 (width 35 mm)
LC1-D40 to D95, LP1-D40 to D80

=
=

127
b
=

=
c
c

a.c. control circuit


LC1- D09…D18 D25…D38 DT20 DT32… LC1- D40…D65 D80 & D95
& DT25 DT60 c (AM1-DL200) (1) 136 147
b 77 85 85 100 c (AM1-DL201) (1) 126 137
c (AM1-DP200 or DR200) (1) 88 94 94 109 c (AM1-EDppp or DE200) (1) 126 137
c (AM1-DE200) (1) 96 102 102 117

d.c. control circuit d.c. control circuit


LC1- D40…D65 D80 & D95
2.3 b 77 85 94 109 c (AM1-DL200) (1) 193 203
c (AM1-DP200 or DR200) (1) 97 103 103 118 c (AM1-DL201) (1) 183 203
c (AM1-DE200) (1) 105 110 111 1236

LP1- D40 D65 D80


c (AM1-DL200) 188 188 198
c (AM1-DL201) 178 178 198

(1) with safety cover (1) with safety cover


On 2 mounting rails DZ5-MB at 120 mm centres
LC1-D115, D150
=
100
158

a.c. or d.c. control circuit


LC1- D115 & D150 D1156 & D1506
=

c (AM1-DP200 or DR200) 134.5 117.5


c c (AM1-DE200 or EDppp) 142.5 125.5

On 2 mounting rails DZ5-MB at 120 mm centres


LC1-D40…D95, LP1-D40…D80
DZ5-ME5
120

110

c 15 40

a.c. control circuit


LC1- D40…D65 D80 & D95
c with cover 119 130

d.c. control circuit


LC1- D40…D65 D80 & D95
c with cover 176 186
LP1- D40 & D65 D80
c 171 181

Selection: Characteristics: References: Schemes:


pages 1/12 to 1/35 pages 2/62 to 2/67 pages 2/74 to 2/77 pages 2/98 and 2/99
2/96 Schneider Electric
24531 Page 97 Thursday, October 25, 2001 6:03 PM

Mounting TeSys contactors


Model d contactors

LC1-D09 to D38 and LC1-DT20…DT60


On 2 mounting rails DZ5-MB
DZ5-ME8
Control circuit: a.c. d.c.
LC1- D09…D18 D25…D38 D09…D18 D25…D38
c with cover 86 92 95 101
G 35 35 35 35
H1

H 60 60 60 60
H

H1 70 70 70 70
4-pole contactors
LC1- DT20 DT32 DT20 DT32
c 15 G
c
& DT25
92
…DT60
100
& DT25
101
…DT60
109
2
G 135 40/50 35 35
H 60 60 60 60
H1 70 70 70 70

LC1-D09…D38 and LC1-DT20…DT60 LC1-D40…D95, LP1-D40…D80


On pre-slotted mounting plate AM1-PA, PB, PC On pre-slotted mounting plate AM1-PA, PB, PC
H

110
c AF1-EA4 G
2.3

c 40 AF1-EA6
Control circuit: a.c. d.c.
LC1- D09…D18 D25…D38 D09…D18 D25…D38
c with cover 86 92 95 101
G 35 35 35 35
c with cover 86 92 95 101
4-pole contactors
LC1- DT20 DT32 DT20 DT32 Control circuit: a.c. d.c.
& DT25 …DT60 & DT25 …DT60 LC1- D40…D65 D80 & D95 D40…D65 D80 & D95
c 80 93 118 132 c with cover 119 130 176 186
G 35 35 35 35 LP1- – – D40 & D65 D80
H 60 60 60 60 c without cover – – 171 181

LC1-D09…D38 LC1-D40…D95, LP1-D40 to D80


Panel mounted Panel mounted
2xM4
=
=

100/110
60/70
=

c = 35 =
=

c = 40 = 3xØ6,5
Control circuit: a.c. d.c.
LC1- D09…D18 D25…D38 D09…D18 D25…D38
c with cover 86 92 95 101 Control circuit: a.c. d.c.
4-pole contactors LC1- D40…D65 D80 & D95 D4…D65 D80 & D95
LC1- DT20 DT32 DT20 DT32 c with cover 119 130 176 186
& DT25 …DT60 & DT25 …DT60 LP1- – – D40 & D65 D80
c with cover 90 98 90 98 c without cover – – 171 181

LC1-D115, D150
Panel mounted
=
130
158

LC1- D115 D1156 D150 D1506


c 132 115 132 115
=

G (3-pole) 96/110 96/110 96/110 96/110


c = G = G (4-pole) 130/144 130/144 – –

Selection: Characteristics: References: Schemes:


pages 1/12 to 1/35 pages 2/62 to 2/67 pages 2/74 to 2/77 pages 2/98 and 2/99
Schneider Electric 2/97
2

2.3
44 43 NO
43/NO A2 A1 A2 A1
54 (93) (94)

2/98
T1/2 1/L1 T1/2 1/L1

T2/4 3/L2 T2/4 3/L2

T3/6 5/L3 T3/6 5/L3

T4/8 7/L4 14 13/NO

22 21/NC

14 13/NO 42 41/NC A2 A1
(91) (92)
22 21/NC 2 1

R2 R1

R4 R3

4 3

54 53/NO A2 A1

62 61/NC R2 R1

2 1

4 3

R4 R3

14 13/NO 54 53/NO

22 21/NC 64 63/NO

32 31/NC

44 43/NO (91)(9 633.163 .942 8392 705 lSEMC1 1 1 rg/GS2 gs2NO

Schneider Electric
154 153/NO A2 A1 56 55/NC 54 53/NO
(183) (184)
68 67/NO 64 63/NO
A1 162 161/NC
(171) (172)
E2 E1
E1 +

K
E2 —

Schneider Electric
A2

154 153/NO 58 57/NO 52 51/NC


(183) (184)
66 65/NC 62 61/NC
164 163/NO
A1
A1 (173) (174)

E1
E1++

K
K
E2
E2——

A2
A2
152 151/NC 56 55/NC 54 53/NO
(181) (182)
68 67/NO
162 161/NC
(171) (172) 64 63/NO

A1 A1

(1)
A1

B1

K
E1 +
54 53/NO

K
A2 64 63/NO
E2 — A2
74 73/NO
A2
84 83/NO

A1
54 53/NO

62 61/NC
E1 +
74 73/NO

K
E2 — 84 83/NO

A2

2/99
2

2.3
24533 Page 100 Friday, October 26, 2001 9:06 AM

Dimensions TeSys contactors


Model d reversing contactors

LC2-D09 to D38 LC2-DT20 to DT60


2 x LC1-D09 to D38 2 x LC1-DT20 to DT60
2xM4 2xM4
e1

=
60/70

60/70
b

b
2 c = G c = G
=

=
= =
e2

e2
a a

LC2- or 2 x LC1- a b c (1) e1 e2 G


D09 to D18 a 90 77 86 4 1.5 80
D093 to D183 a 90 99 86 – – 80
D09 to D18 c 90 77 95 4 1.5 80
D093 to D183 c 90 99 95 – – 80
D12004 – 74 80 – 6 95
D25 to D38 a 90 85 92 9 5 80
D253 to D383 a 90 99 92 – – 80
D25 to D32 c 90 85 101 9 5 80 LC2- or 2 x LC1- a b c G
D253 to D383 c 90 99 101 – – 80 DT20 and DT25 90 85 90 80
D25004 – 84 93 – 7 111 DT32…DT60 90 91 98 80
e1 and e2: including cabling. c, e: including cabling.
2.3 (1) With safety cover, without add-on block.
LC2-D40 to D65
2 x LC1-D40 to D65 2 x LP1-D40 and D65
6xØ6,5 6xØ6,5
e1

e1

= G1 = = G1 =
8

8
100/110

100/110
b

13
13

= 40 G 40 = = 40 G 40 =
e2

c c
e2

a a

LC2- or 2 x LC1- a b c e1 e2 G G1
D40 to D65 165 127 142 5 – 50 90
D40004 182 127 133 – 11 57 97
D65004 182 127 133 – 11 57 97 LC2- or 2 x LC1- a b c e1 e2 G G1
D80 and D95 182 127 158 13 – 57 96 D40 to D65 182 127 190 5 11 57 97
D80004 207 127 158 – 20 71 111 D80 and D95 207 127 215 13 20 96 111
c, e1 and e2: including cabling. c, e1 and e2: including cabling.

LC2-D115 and D150


2 x LC1-D115 and D150
e1

=
158

130
=

= G =
e2

c a

LC2- or 2 x LC1- a c e1 e2 G
D115, D150 266 148 56 18 242/256
D115004 334 148 – 60 310/324
c, e1 and e2: including cabling.

Selection: Characteristics: References: Schemes:


pages 1/12 to 1/35 pages 2/62 to 3/67 pages 2/74 to 2/83 page 2/101
2/100 Schneider Electric
24533 Page 101 Friday, October 26, 2001 9:07 AM

Schemes TeSys contactors


Model d reversing contactors

Reversing contactors for motor control, horizontally mounted Reversing contactors for motor control with integral electrical
LC2-D09…D150 interlocking (LAD-9R1V)

L1

L2

L3
L1

L2

L3

13/NO

13/NO

13/NO

13/NO
21/NC

21/NC

21/NC

21/NC
3

3
5

5
1

3
5

5
1

1
A1

A1

A1

A1
2
A2

A2

A2

A2
22

22
6

14

14
2

22

22
6

14

14
2

4
W
U

W
U

V
Changeover contactor pairs, horizontally mounted
LC2-DT20…DT60
1/L1

1/L2

1/L3

1N

2/L1

2/L2

2/L3

2N
3

3
5

7
1

1
A1

A1

2.3
A2

A2
6

8
2

4
L1

L2

L3

Electrical interlocking of reversing contactors fitted with:


mechanical interlock with integral electrical contacts mechanical interlock without integral electrical contacts
LA9-Dppp02 LA9-Dppp78, LAD-9R1
A1
A2

A1
A2

02

02
01

– KM2 – KM1
01

01

01
– KM1 – KM2
02
A1

A1
A1

A1
02

– KM1 – KM2 – KM1 – KM2


A2

A2

A2

A2
A2

A2

Low speed - High speed cabling kit


L1

L2

L3

13/NO

13/NO
21/NC

21/NC
3

3
5

5
1

1
A1

A1
A2

A2
22

22
6

14

14
2

W
U

LAD- LS/HS
R1

R3
1

3
A1
A2

4
R2

R4

Low speed High speed

Selection: Characteristics: References: Dimensions:


pages 1/12 to 1/35 pages 2/62 to 3/67 pages 2/74 to 2/83 page 2/100
Schneider Electric 2/101

Potrebbero piacerti anche