3 Functionality ................................................................................................... 5
FIGURES
TABLES
1 Overview
In general, GSM/EDGE/UMTS system consists of Core Network (CN), Radio Network
Subsystem (GERAN/UTRAN) and Mobile Station/User Equipment (MS/UE).
GERAN/UTRAN includes 2 network elements, base station and BSC/RNC. The
conventional 2G/3G BTS connects to BSC/RNC or MS/UE via Abis/Iub or Um/Uu
interface respectively. The flowing figureErro! Fonte de referência não encontrada.
shows a conventional GSM/EDGE/UMTS network system.
BTS BSC
3G UTRAN Only
Node B
HLR
RNC
UMTS
RNC
IP Network
Node B
SGSN GGSN
In the figure 1, GPRS/EDGE and UTRAN are two separated radio networks. When ZTE
2G/3G dual-mode base station is introduced, the 2G/3G radio networks will be converged
into one and this will decrease the network construction cost greatly. The GSM/UMTS
integrated network is shown in following Figure.
IP Network
SDR BTS
SGSN GGSN
The purpose of this document is to describe the MCPA based SDR Remote Radio Unit
(RRU) – ZXSDR R8860E, which adopts the unified MicroTCA platform to support all
kinds of wireless access technology including GSM, UMTS, CDMA2000, and WiMAX.
Also it supports the type of ZXSDR R8860E for GSM/UMTS dual mode.
Next descriptions are giving a general overview to the ZXSDR R8860E for GSM/UMTS
dual mode.
2 Highlight Features
l It can flexibly support both GSM and UMTS with software configuration. For the
multi-mode configuration, R8860E can support 4 GSM TRXs plus 1 UMTS carrier or
2 GSM TRXs plus 2 UMTS carriers.
l For GSM configuration, the typical power consumption is less than 200 W (6TRX);
For UMTS configuration, the typical power consumption is less than 155 W (1
carrier); For GU dual mode configuration, the typical power consumption is less than
215 W (4 TRX+1 carrier).
3 Functionality
R8860E is the radio part of full function base station. The signal is transmited/received
through R8860E to base band processing unit for a further processing by CPRI interface.
l Co-cabinet can support transmit diversity, without adding antenna achieving same
receiving sensitivity;
l One R8860E software fault for itself will not affect the running of BBU and other
RRU.
4 System Architecture
Frequency expansion
9 RXin N-KY (MIL-C-39012 or IEC169-16)
interface
2
10 GND Machine Grounding Section area of cable is 16 mm
R8860E indicators and buttons locate at the left bottom of front cabinet, as shown in the
flowing figureErro! Fonte de referência não encontrada..
For descriptions about indicators and buttons see the flowing tableErro! Fonte de
referência não encontrada..
RST
- Reset button Press this key to reset R8860E
button
Press once RF switch state to handover or
- RF button RF switch button
do standing wave ratio (SWR) check
Optical interface Press once this key to detect whether
- CAL
detection button optical port is normal by self-loop
l PA (Power Amplifier)
RIE PIB PA
ADTR
PA Out
CPRI 1
CPRI 2
PWR ALM
l Extract clock reference signal from baseband unit, provide clock for different
modules;
l Environment Detection;
l Provide 2 paths of baseband–RF interface and 4 paths of external alarm input, and a
serial port, a FE interface, a RS232 interface, and a AISG interface;
l Feedback forward power coupling signal to ADTR, and ADTR do forward power
inspection;
l Feedback backward power coupling signal to ADTR, and ADTR do backward power
(SWR) inspection;
l Access following these signals from PIB board: Ethernet signal, 485 dry contact,
LED indicator, single board reset signal, jumper, button signal, digital ground;
l Transmit the access signal by the socket and finish the function of interface
conversion.
l Power, ground, and 485 signal of electrically tuned antenna, output to electrically
tuned antenna by socket; other signals are introduced to outside by test socket, to do
debug and use as indicative signal;
l Finish interference protection for indicators, reset signals, buttons, and jumpers.
l Finish power conversion from DC to DC, and provide power supply function;
Application
OAM RFS
VxWorks BSP
Hardware
Hardware System
Application layer consists of RFS (Radio Frequency Sub-system) and OAM (Operating
and Maintenance) sub-systems. Its main function contains software downloading,
configuration, management, system maintenance and measurement.
OSS (Operation Support Sub-system) is the support layer in this entire framework, which
is a hardware irrespective platform for running software and provides basic functions like
scheduling, timer, memory management, communication, sequencing control, monitoring,
alarming and logging.
BSP (Board Support Package) supports the information routing to the GSM, UMTS and
public parts in the application layer.
5 Technical Specifications
Item Indices
Appearance
5.2 Capacity
5.3 Performance
5.4 Power
Item Indices
DC: -48 V (-37 V - -57 V DC)
power supply
AC: 110 V/220 V (90 V – 290 V AC)
Item Indices
Typical power consumption (6 TRXs) 200 Watt
Item Indices
Item Indices
Typical power consumption (4TRXs+1C) 215Watt
5.5 Transmission
Interface Valu
Item Interface Kind Standard
Name e
Baseband-R CPRI
2 SFP (LC) CPRI 2.0
F interface interface
External
RS485 37-core aviation
monitoring 1 GJB599Ⅲ
interface socket
interface
10M/100M/1000
Local M
FE
maintenance 1 RJ45
interface Auto-Negotiation
interface
Auto-MDI/MDIX
Antenna
Antenna port 50 ohms N IEC60169-4/CECC22190/DI
connecto 2
interface Connector N 47223
r
Electrical
down-tilt
AISG
adjustable 1 8-cores socket IEC 60130-9-ED
interface
antenna
interface
External Dry
37-core aviation
alarm contact 4 GJB599Ⅲ
socket
interface input
Item Indices
Temperature -40°C - +55°C
Relative humidity 5% - 100%
Item Indices
Ingress Protection IP65
Grounding resistance < 5 ohm
5.7 EMC
Item Indices
Contact Discharge: ±6000V
Static Discharge Immunity
Air Discharge: ±8000V
Surge Impact Immunity DC Power port Line(Ground): ±2000V
5.8 Reliability
In ZXSDR R8860E, the algorithm of system reliability is based on the GJB/Z299B
Electronic Equipment Reliability Estimation Manual and MIL-HDBK-217F Electronic
Equipment Reliability Estimation.
Item Indices
MTBF ≥380,000 hours
MTTR 60 minutes
Availability Index 99.999737%
System service interruption time ≤1.383 mins/year