Sei sulla pagina 1di 2

Enclosed Miomi

CONSTRUCTION FEATURES
Door Conslruction One-piece high impact strength, End Plates Die-cast aluminum.
-
high transmission internally ribbed fully luminous acrylic -
Outer Housing-Formed from one-piece aluminum.
lens gasketed with polyurethane weather stripping for
moisture, dust and insect resistance. Full length alumi- Retlector- Heat treated extruded aluminum reflector/
num captive door retainers. wjreway cover finished with high reflectance, white,
baked-on enamel.
Sockets-Sockets are recessed double contact, arc
and burnout resistant, with wide leaf spring terminals. Finish Standard baked-on enamel paint finish is white.
A 16 pound non-electrical load carrying spring one end,
-
Mounting Designed for single fixture or continuous
slationary at the other end. - with knockouts for wireways.
row mounting
Ballasls Mounted against outer housing for cool, long Modular Length 48", 72" and 96" lengths or multiples
-
life operation. Outer housing embossed to permit air cir- thereof for easy -continuous row mounting.
culation over all sides. Class "P" ballast optional.

J.H. SPALrLDlltlG
Subsidiary ol Walter K dde & Company, lnc.
KIDOE
1736 Dreman Avenue Cincinnati, Ohio 45223 (513) 541-3486
c5
ISOFOOTCAN DLE CURVES lnonrzonrnrl
LUMINAIRE SERIES : B ElVll-1 -1500
LAN/IP TYPE : 1500MA
TESTED AT AMBIENT TEMPERATURE 77'F.
N T AL tsOR Z FOOTCANDLES
o MOUNTING HE GHT

'15 11.1

10 74 56
5 37 2A

2
BATIO : DISTANCE
MOUNTING HEIGHT
This rcpott has been ptepared in accatdance with IES guides on testing ptocedutes. /t ls represertalive of luminaires tested undet
standardized and stabilized labotalory conditions. Vatious operating factots can cause dift'ercnces between laboratory data and actual
field peiotmance.

ORDERING INFORMATION
|..r."*. Troo.. oFDTBTNG \uMBFBs f ;t
I rrrcru ruuvarn
I r!oo@ l orscnrertor ltBs. I

4', 4 EMt-1 37006'285 4' Unit 25


6 EMt-1 37006 08 7 37006-30 1 6'Unit
8', 8 EMt-1 37006-10 3 37006-32 7 8' Unit
10' 10 EMt-1 37006-12I 37006-34 3 6'+4'unil
'12' 12 EMI-l 37006-14 5 37006-36 8 6'+6'Unit
14'. 14 Et\fl-1 37006-16 0 37006 38 4 S +6'Unit
16 16 EMI-1 37006 18 6 37006 40 0 8'+8'Unit
18' 18 Elvll-1 37006-20 2 37006-42 6 6'+6'+6'unit
20' 20 EMt-1 37006-22 A 37006-44 2 8',+6',+6',Unit
22 22 EMll 37006 24 4 37006 46 7 8'+8'+6'Llnit
,4 24 EMt-1 37006-26 I 37006-48 3 8'+8'+8'LJnit
26', 26 E,4t-1 3Z09ji9l 37006-70 7 12'+14' UniI
28 EMt-1 37006-51 7 37006-71 5 14'+14'ljnit
30 EMl,1 37006-s2 5 37446 72 3 '14'+16'Unit
32 EMt-1 37006 53 3 37006,73 1 '16'+16'LJnit 98
1a- 34 EMt-1 37006-54 1 37006-74 9 16'+1a'Unit 114
36 Et\,1t-1 37006 55 8 37006-75 6 12'+24' Unit 117
38' 38 Et\lt-1 37006-56 6 37006-76 4 14'+24' Unil
40 Et\,4t-1 37006-57 4 37A06-77 2 16'+24'lJnit '130

42 FMt-1 37006-58 2 37006-78 0 18'+24'Unit 138


44'. 44 EMt-1 37006 59 0 37006-79 8 2A'+24'Unit 147
46 EMt-1 37006-60 8 37006-80 6 22'+24' Unit 149
48 Er\41-1 37006-61 6 37006-81 4 24'+24'UniI 154
NOTE: Slandard ballast voltage is 120 volts- Other vollages available upon request.

OPTIONS
Class 'P" ballast add suffix "P'to ordering number.

ISOFOOTCANDLE CONVERSION MULTIPLIERS


It is possible to use the following multipliers to calculate 6 ft. 1500t\,,tA PG, VHO or SHO Lamp ........... .70
footcandle levels produced lrom lamps other than 8 fool 4 ft. 1500MA PG, VHO or SHO Lamp ........... .45
1500N/lA lamps. Multiply each lootcandle curve value as I ft. 800MA High Output Lamp .... .......... .57
shown on isofootcandle chart by desired lamp type (either 6 ft. 800MA High Output Lamp .... ........... .41
individual or continuous row curves). 4'tt. BootvlA High Output Lamp . .. ........ . ... ,25

Potrebbero piacerti anche