Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
MTS3
iOS Android
UART Indicator
WLAN Indicator
WIFI Indicator
power button
Gateway
www
cloud www
App Operation
Button
WIFI,GSM/GPRS Shifting between
LAN, RS485 WIFI WLAN and WIFI
NB-IoT,
Z-Wave, Zigbee,LoRa & reset
Communication module
Pushbutton Switch
Switching on/off & communication indicator
iMCB
iRCBO
Indicator
MTS3 is a smart electric safety supervision and power The system raises a pre-alarm before reporting a on/off status Ethernet Cat
RJ45 RS485
Management system that includes both hardware and failure. This device has features like Online power
software, which integrates the most latest & advanced management, real-time power efficiency monitoring,
Connection pin
technologies like AI, Big data, IoT and cloud computing. real-time monitoring of electrical circuit parameter
(voltage, current, power KWH, etc), and are reported,
Power supply module with surge protection
which help identify where energy savings are required,
and further save power bills through analysis of
collected data, power consumption analysis.
01 www.mantunsci.com www.mantunsci.com 02
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Overview Structure
UART Indicator
WLAN Indicator
WIFI Indicator
power button
Gateway
www
cloud www
App Operation
Button
WIFI,GSM/GPRS Shifting between
LAN, RS485 WIFI WLAN and WIFI
NB-IoT,
Z-Wave, Zigbee,LoRa & reset
Communication module
Pushbutton Switch
Switching on/off & communication indicator
iMCB
iRCBO
Indicator
MTS3 is a smart electric safety supervision and power The system raises a pre-alarm before reporting a on/off status Ethernet Cat
RJ45 RS485
Management system that includes both hardware and failure. This device has features like Online power
software, which integrates the most latest & advanced management, real-time power efficiency monitoring,
Connection pin
technologies like AI, Big data, IoT and cloud computing. real-time monitoring of electrical circuit parameter
(voltage, current, power KWH, etc), and are reported,
Power supply module with surge protection
which help identify where energy savings are required,
and further save power bills through analysis of
collected data, power consumption analysis.
01 www.mantunsci.com www.mantunsci.com 02
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Hardware Introdution Features
Power supply module with surge protection Smart Metering Breaker - iMCB Device extendable
This is a modular device which can be extendable as
traditional MCB and RCBO. It withstands maximum
current up to 80A. 1,2,3 & 4Pole for iMCB are available.
Minimum space requirement
Except for Power supply module of 36mm and
Communication module of 18mm, the iMCB and iRCBO
have an extra 9mm or 18mm control module, different
from traditional MCB and RCBO.
Very simple installation
All devices are mounted in 35mm Din Rail and connected
by connection pins or flexible flat cable. No special tools
are required for the entire connection process.
System compatibility
Provides DC power for smart circuit breaker and Full protection :
This system can be compatible with other systems, such
communication module. Overload,Short circuit,Over/under voltage
as smart home, fire monitoring system, energy efficiency
Provides lightning & surge protection. Arcing fault,Phase loss,Unbalance,High temperature management system, smoke and voice control etc..
Main technical parameters: Main technical parameter: Electrical faults analysis
Input voltage: 100-250 V AC Poles: 1P, 2P, 3P, 4P The system can realize real-time analysis of all
Input current: 3.5 A Rated Current (A): 10, 16, 20, 25, 32, 40, 50, 63, 80 electrical faults of both main and branch lines: short
circuit, earth leakage, overload, over/under voltage,
Output voltage: 12 VDC Breaking Capacity: 6000 A
overheated, arc fault, etc..
Imax for lightning protection: 15 kA Curve: B, C, D
Monitor of electrical circuit parameter
Working with max.10pcs iRCBO or iMCB
The system can realize real-time monitoring of
electrical circuit parameters: voltage, current, power
Smart metering breaker - iRCBO Communication module ,temperature, residual current and KWH.
Full protection
This system includes all protections: overload, short
circuit, earth leakage, surge, over/under voltage, arcing
fault, phase loss, unbalance, high temperature
Max. power and current setting
The power and current under rated current and power
can be adjustable through the App or software platform
03 www.mantunsci.com www.mantunsci.com 04
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Hardware Introdution Features
Power supply module with surge protection Smart Metering Breaker - iMCB Device extendable
This is a modular device which can be extendable as
traditional MCB and RCBO. It withstands maximum
current up to 80A. 1,2,3 & 4Pole for iMCB are available.
Minimum space requirement
Except for Power supply module of 36mm and
Communication module of 18mm, the iMCB and iRCBO
have an extra 9mm or 18mm control module, different
from traditional MCB and RCBO.
Very simple installation
All devices are mounted in 35mm Din Rail and connected
by connection pins or flexible flat cable. No special tools
are required for the entire connection process.
System compatibility
Provides DC power for smart circuit breaker and Full protection :
This system can be compatible with other systems, such
communication module. Overload,Short circuit,Over/under voltage
as smart home, fire monitoring system, energy efficiency
Provides lightning & surge protection. Arcing fault,Phase loss,Unbalance,High temperature management system, smoke and voice control etc..
Main technical parameters: Main technical parameter: Electrical faults analysis
Input voltage: 100-250 V AC Poles: 1P, 2P, 3P, 4P The system can realize real-time analysis of all
Input current: 3.5 A Rated Current (A): 10, 16, 20, 25, 32, 40, 50, 63, 80 electrical faults of both main and branch lines: short
circuit, earth leakage, overload, over/under voltage,
Output voltage: 12 VDC Breaking Capacity: 6000 A
overheated, arc fault, etc..
Imax for lightning protection: 15 kA Curve: B, C, D
Monitor of electrical circuit parameter
Working with max.10pcs iRCBO or iMCB
The system can realize real-time monitoring of
electrical circuit parameters: voltage, current, power
Smart metering breaker - iRCBO Communication module ,temperature, residual current and KWH.
Full protection
This system includes all protections: overload, short
circuit, earth leakage, surge, over/under voltage, arcing
fault, phase loss, unbalance, high temperature
Max. power and current setting
The power and current under rated current and power
can be adjustable through the App or software platform
03 www.mantunsci.com www.mantunsci.com 04
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Benefits Software Introduction
APP (Android/IoS)
It includes six functions:
Power consumption
Remote control, Real-time monitoring, Event alarm and push,
Power concumption curve of main lines and each sub-
Power consumption curve, Timer, Max. Power and Current
lines may be showed in APP monthly and hourly.
Continuous monitoring of electrical parameters of each The cost of energy will rise continuously. In order to cut costs, setting, auto-test of Residual Current.
breaker including both main and branch lines (such as current, we first have to identify where they occur. The smart power
Event alarm and push
voltage, earth leakage current, power and temperature) management system helps illustrate and analyze the All the events recorded and fault alarm will be pushed
makes it possible to detect the early electrical faults and instantaneous energy consumption levels and realize the real- through App.
make early-warning before any unforeseen event. It improves time power efficiency monitoring. Furthermore, the calculated
the safety and reliability and electrical system and may be active energy can be used to roughly allocate the costs at the Auto-test of residual current
used widely in building as fire system solution. Auto-test of earth leakage current in fixed date each
output level. Therefore, it helps identify energy saving, and
month in the App instead of manual test monthly
further to save energy cost, through analysis of collected data
and power consumption. Timer
Users are able to remotely set the power demand they
want to target with a weekly,daily or hourly resolution
Remote control
Remote control
iMCB and iRCBO can be operated individually or be
switched on/off all together through App remotely. And
for safety, it can not be switch on through APP after
switching off manually.
Real-time monitoring
The system monitors electrical circuit parameters :
voltage, current, Power ,temperature, Residual Current
and KWH and these parameters may be showed in APP.
The hardware device may be controlled by App and software
anytime and anywhere, to make life easier and safer.
Max. Power and current setting
The max. power and current may be set through APP and
the seting value must lower than rated current and power.
05 www.mantunsci.com www.mantunsci.com 06
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Benefits Software Introduction
APP (Android/IoS)
It includes six functions:
Power consumption
Remote control, Real-time monitoring, Event alarm and push,
Power concumption curve of main lines and each sub-
Power consumption curve, Timer, Max. Power and Current
lines may be showed in APP monthly and hourly.
Continuous monitoring of electrical parameters of each The cost of energy will rise continuously. In order to cut costs, setting, auto-test of Residual Current.
breaker including both main and branch lines (such as current, we first have to identify where they occur. The smart power
Event alarm and push
voltage, earth leakage current, power and temperature) management system helps illustrate and analyze the All the events recorded and fault alarm will be pushed
makes it possible to detect the early electrical faults and instantaneous energy consumption levels and realize the real- through App.
make early-warning before any unforeseen event. It improves time power efficiency monitoring. Furthermore, the calculated
the safety and reliability and electrical system and may be active energy can be used to roughly allocate the costs at the Auto-test of residual current
used widely in building as fire system solution. Auto-test of earth leakage current in fixed date each
output level. Therefore, it helps identify energy saving, and
month in the App instead of manual test monthly
further to save energy cost, through analysis of collected data
and power consumption. Timer
Users are able to remotely set the power demand they
want to target with a weekly,daily or hourly resolution
Remote control
Remote control
iMCB and iRCBO can be operated individually or be
switched on/off all together through App remotely. And
for safety, it can not be switch on through APP after
switching off manually.
Real-time monitoring
The system monitors electrical circuit parameters :
voltage, current, Power ,temperature, Residual Current
and KWH and these parameters may be showed in APP.
The hardware device may be controlled by App and software
anytime and anywhere, to make life easier and safer.
Max. Power and current setting
The max. power and current may be set through APP and
the seting value must lower than rated current and power.
05 www.mantunsci.com www.mantunsci.com 06
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Software Platform Software Platform
The software platform includes two main parts: electrical Early warning and alarms Power Management
safety supervision and power management. Early warning and alarm information in software platform In this software platform, the user will find the basic Power consumption statistic, analysis and comparison
Electrical Safety Supervision can be read /understood as follows: analytic functions such as a dashboard data, instantaneous Power consumption comparison between current month
The system will monitor all the electrical circuit parameter Alarm of earth leakage current values, comparison functions and cost allocation by and last month
of all main and branch lines in real-time such as voltage, Early warning of earth leakage current consumer group. Power consumption percentage of current month in the
current, Power ,temperature, residual current and KWH Early warning of high temperature The building energy flows and costs are transparent, total amount of the whole year.
and it may do pre-judgement and action through these Autotest function of earth leakage protection therefore, this solution is suitable for energy management Power consumption statistic and sum of each classified
electrical data collection and analysis. Early warning and alarm of overload and over current and energy cost allocation application seeking energy divisions
Device location montioring Early warning and alarm of over voltage and undervoltage efficiency improvement and cost reductions. Power consumption comparison monthly in last two years
After installation, the location information of each device Alarm of short circuit
The platform realizes the collection, storage, management Load statistic and comparison
will be recorded and showed in the map in software Alarm of unbalance
and efficient use of the terminal energy information. It Load status and comparison of today and yesterday
platform. The software platform will monitor the real-time Alarm of electricity fraud
analyzes, processes, handles all energy data, and output to Load status and comparison of this week and last week
status of all device installed all over the world, in case
Electrical parameter monitoring keep the system run in best state, after system intelligent Load status and comparison of this year and last year
early warning or fault alarm raised, the supervisor can
Electrical parameter monitoring in software platform can configuration.
identify the device and its location quickly, then resolve Control and Management
be read/understood as follows:
the problem accordingly before any unforeseen event. In order to further provide conditions for mining, analyzing,
Temperature monitoring Rename of each device
processing and handling energy data, The energy efficiency
Current monitoring Remote control
Information management management system we built, can not only effectively solve
Voltage monitoring Scene setting with timer function
Through software platform, you can easily view contact real-time energy balance and monitoring management, but
Power monitoring Password management
information of technician of each project management site. In also build up condition to further dig, analyze, process, handle
Earth Leakage current monitoring
case of any warning/alarm raised, the software platform data, through filing and management of a large amount of
sends an alert to the contact person so that he deals with it historical data.
immediately.
07 www.mantunsci.com www.mantunsci.com 08
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Software Platform Software Platform
The software platform includes two main parts: electrical Early warning and alarms Power Management
safety supervision and power management. Early warning and alarm information in software platform In this software platform, the user will find the basic Power consumption statistic, analysis and comparison
Electrical Safety Supervision can be read /understood as follows: analytic functions such as a dashboard data, instantaneous Power consumption comparison between current month
The system will monitor all the electrical circuit parameter Alarm of earth leakage current values, comparison functions and cost allocation by and last month
of all main and branch lines in real-time such as voltage, Early warning of earth leakage current consumer group. Power consumption percentage of current month in the
current, Power ,temperature, residual current and KWH Early warning of high temperature The building energy flows and costs are transparent, total amount of the whole year.
and it may do pre-judgement and action through these Autotest function of earth leakage protection therefore, this solution is suitable for energy management Power consumption statistic and sum of each classified
electrical data collection and analysis. Early warning and alarm of overload and over current and energy cost allocation application seeking energy divisions
Device location montioring Early warning and alarm of over voltage and undervoltage efficiency improvement and cost reductions. Power consumption comparison monthly in last two years
After installation, the location information of each device Alarm of short circuit
The platform realizes the collection, storage, management Load statistic and comparison
will be recorded and showed in the map in software Alarm of unbalance
and efficient use of the terminal energy information. It Load status and comparison of today and yesterday
platform. The software platform will monitor the real-time Alarm of electricity fraud
analyzes, processes, handles all energy data, and output to Load status and comparison of this week and last week
status of all device installed all over the world, in case
Electrical parameter monitoring keep the system run in best state, after system intelligent Load status and comparison of this year and last year
early warning or fault alarm raised, the supervisor can
Electrical parameter monitoring in software platform can configuration.
identify the device and its location quickly, then resolve Control and Management
be read/understood as follows:
the problem accordingly before any unforeseen event. In order to further provide conditions for mining, analyzing,
Temperature monitoring Rename of each device
processing and handling energy data, The energy efficiency
Current monitoring Remote control
Information management management system we built, can not only effectively solve
Voltage monitoring Scene setting with timer function
Through software platform, you can easily view contact real-time energy balance and monitoring management, but
Power monitoring Password management
information of technician of each project management site. In also build up condition to further dig, analyze, process, handle
Earth Leakage current monitoring
case of any warning/alarm raised, the software platform data, through filing and management of a large amount of
sends an alert to the contact person so that he deals with it historical data.
immediately.
07 www.mantunsci.com www.mantunsci.com 08
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Applications Application Examples
SHANGHAI ELECTRIC POWER INDUSTRY SCHOOL
Hospitals
09 www.mantunsci.com www.mantunsci.com 10
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Applications Application Examples
SHANGHAI ELECTRIC POWER INDUSTRY SCHOOL
Hospitals
09 www.mantunsci.com www.mantunsci.com 10
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Application Examples Application Examples
HOTEL
The “Smart Electricity” APP helps hospitals to The “Smart Electricity” system can realize 7×24-
realize terminal power collection, store large hour school monitoring, get out of the limit and
Internet cloud amounts of data in real time, acquire first-hand low efficiency of human work, and monitor the
data in real time, develop data center to extract, device operation status in real time through IoT
dig, analyze and summarize data, and finally system.
provide proof for important decisions.
11 www.mantunsci.com www.mantunsci.com 12
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Application Examples Application Examples
HOTEL
The “Smart Electricity” APP helps hospitals to The “Smart Electricity” system can realize 7×24-
realize terminal power collection, store large hour school monitoring, get out of the limit and
Internet cloud amounts of data in real time, acquire first-hand low efficiency of human work, and monitor the
data in real time, develop data center to extract, device operation status in real time through IoT
dig, analyze and summarize data, and finally system.
provide proof for important decisions.
11 www.mantunsci.com www.mantunsci.com 12
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Instruction of Type Code for Power Supply Module Technical Specification of Power Supply Module
Input current: Power supply module will offer stable DC power for smart breaker MTS3 and owns class II surge protection. It is also the
Company code series code 2.5A necessary part for smart breaker MTS3 system.
MT S 3 C WF
13 www.mantunsci.com www.mantunsci.com 14
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Instruction of Type Code for Power Supply Module Technical Specification of Power Supply Module
Input current: Power supply module will offer stable DC power for smart breaker MTS3 and owns class II surge protection. It is also the
Company code series code 2.5A necessary part for smart breaker MTS3 system.
MT S 3 C WF
13 www.mantunsci.com www.mantunsci.com 14
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Technical Specification of iRCBO Technical Specification of iMCB
Smart RCBO can be used as main switch and line protection in Smart Breaker MTS3 system. It is also the necessary part Smart Breakers are the core part of MTS3 smart system, it combines protection, metering, monitor, timer, automation,
for Smart Breaker MTS3 system as main switch. event record and notice.
Order Code MTS3-R2 MTS3-R4 Order Code MTS3-M1 MTS3-M2 MTS3-M3 MTS3-M4
Product Code S3-ZNC S3-TZC Product Code S3-FC S3-FNC S3-TC/TD S3-TNC/TND
Picture Picture
15 www.mantunsci.com www.mantunsci.com 16
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Technical Specification of iRCBO Technical Specification of iMCB
Smart RCBO can be used as main switch and line protection in Smart Breaker MTS3 system. It is also the necessary part Smart Breakers are the core part of MTS3 smart system, it combines protection, metering, monitor, timer, automation,
for Smart Breaker MTS3 system as main switch. event record and notice.
Order Code MTS3-R2 MTS3-R4 Order Code MTS3-M1 MTS3-M2 MTS3-M3 MTS3-M4
Product Code S3-ZNC S3-TZC Product Code S3-FC S3-FNC S3-TC/TD S3-TNC/TND
Picture Picture
15 www.mantunsci.com www.mantunsci.com 16
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Technical Specification of Communicaiton Module Ordering Information
Communication module includes wireless and wired mechanism’s. It also functions as hotspot. Power supply module
Numbers of
Input & Output Input & Output Lighting LCD Weight
Order Code MTS3-C Pictures Order Code Product Code Modules( 1
voltage (V) Current(A) Protection Display Unit: g
Product Code S3-T30/RS485/Zigbee/NB-IoT/T2G/T4G/LoRa module=18mm)
Picture
Input: Input:
100-250VAC 350mA Isn: 10kA
No
Imax: 15kA MTS3-P25 MTS3-P25 2(36mm) 187
Output: Output:
12VDC 2500mA
Standards: EN301489,EN300328,EN62479,EN60950
Approvals: CE,CCC
Types Vdc TCP/IP, RS485,Wi-Fi, GPRS-2G, NB-IoT, Zigbee, LoRa Input: Input:
Rated input voltage 12 100-250VAC 350mA
Isn: 10kA
Numbers of modules( 1 module=18mm) 1 (18mm) MTS3-P25D MTS3-P25D 2(36mm) 187
Imax: 15kA Yes
Max. working capacity ( Max.numbers of breaker powering) mm² (iRCBO+ iMCB) x 32pcs Output: Output:
Conductor cross-sections 38 12VDC 2500mA
Pollution degree ºC 2
Ambient temperature: ºC -15 - +40
Storage temperature: -25---+70 Communication Module
Humidity m < 95% Numbers of
Altitude: Rated Communication Order Product Weight
<=2000 Pictures Modules( 1
Terminal connection voltage type Code Code Unit: g
Cable/Pin-type busbar module=18mm)
Mounting Din rail EN60715(35mm) by means of fast clip TCP/IP, Wi-Fi MTS3-CWF S3-T30/WF
Connection Both from top to bottom or reverse RS485 MTS3-CRS S3-RS485
ZigBee MTS3-CZB S3-ZigBee
12VDC NB-IoT MTS3-CNB S3-T30/NB-E8 1(18mm) 2.43
LoRa MTS3-CLR S3-LoRa
GPRS-2G MTS3-CG2 S3-T30/2G
GPRS-4G MTS3-C4G S3-T30/4G
Z-Wave MTS3-CZW S3-Z-Wave
Accessory
Connection
6 pins MTS3-P6 S3-pin 0.01
pin
40mm MTS3-CT50 S3-50line 0.6
flexible 50mm MTS3-CT60 S3-60line 0.7
flat cable 60mm MTS3-CT80 S3-80line 0.8
iRCBO module
Rated Rated Numbers of
Number RCD Order Product Weight
Pictures Curve residual current Modules( 1
of poles type Code Code Unit: g
current (mA) In (A) module=18mm)
16 MTS3-R2AC30C16 S3-ZNC16
32 MTS3-R2AC30C32 S3-ZNC32 3(54mm) 367
63 AC MTS3-R2AC30C63 S3-ZNC63
C 2P 30 80 MTS3-R2AC30C80 S3-ZNC80
32 MTS3-R4AC30C32 S3-TZC32
63 MTS3-R4AC30C63 S3-TZC63 5(90mm) 787
80 AC MTS3-R4AC30C80 S3-TZC80
C 2P 30
17 www.mantunsci.com www.mantunsci.com 18
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Technical Specification of Communicaiton Module Ordering Information
Communication module includes wireless and wired mechanism’s. It also functions as hotspot. Power supply module
Numbers of
Input & Output Input & Output Lighting LCD Weight
Order Code MTS3-C Pictures Order Code Product Code Modules( 1
voltage (V) Current(A) Protection Display Unit: g
Product Code S3-T30/RS485/Zigbee/NB-IoT/T2G/T4G/LoRa module=18mm)
Picture
Input: Input:
100-250VAC 350mA Isn: 10kA
No
Imax: 15kA MTS3-P25 MTS3-P25 2(36mm) 187
Output: Output:
12VDC 2500mA
Standards: EN301489,EN300328,EN62479,EN60950
Approvals: CE,CCC
Types Vdc TCP/IP, RS485,Wi-Fi, GPRS-2G, NB-IoT, Zigbee, LoRa Input: Input:
Rated input voltage 12 100-250VAC 350mA
Isn: 10kA
Numbers of modules( 1 module=18mm) 1 (18mm) MTS3-P25D MTS3-P25D 2(36mm) 187
Imax: 15kA Yes
Max. working capacity ( Max.numbers of breaker powering) mm² (iRCBO+ iMCB) x 32pcs Output: Output:
Conductor cross-sections 38 12VDC 2500mA
Pollution degree ºC 2
Ambient temperature: ºC -15 - +40
Storage temperature: -25---+70 Communication Module
Humidity m < 95% Numbers of
Altitude: Rated Communication Order Product Weight
<=2000 Pictures Modules( 1
Terminal connection voltage type Code Code Unit: g
Cable/Pin-type busbar module=18mm)
Mounting Din rail EN60715(35mm) by means of fast clip TCP/IP, Wi-Fi MTS3-CWF S3-T30/WF
Connection Both from top to bottom or reverse RS485 MTS3-CRS S3-RS485
ZigBee MTS3-CZB S3-ZigBee
12VDC NB-IoT MTS3-CNB S3-T30/NB-E8 1(18mm) 2.43
LoRa MTS3-CLR S3-LoRa
GPRS-2G MTS3-CG2 S3-T30/2G
GPRS-4G MTS3-C4G S3-T30/4G
Z-Wave MTS3-CZW S3-Z-Wave
Accessory
Connection
6 pins MTS3-P6 S3-pin 0.01
pin
40mm MTS3-CT50 S3-50line 0.6
flexible 50mm MTS3-CT60 S3-60line 0.7
flat cable 60mm MTS3-CT80 S3-80line 0.8
iRCBO module
Rated Rated Numbers of
Number RCD Order Product Weight
Pictures Curve residual current Modules( 1
of poles type Code Code Unit: g
current (mA) In (A) module=18mm)
16 MTS3-R2AC30C16 S3-ZNC16
32 MTS3-R2AC30C32 S3-ZNC32 3(54mm) 367
63 AC MTS3-R2AC30C63 S3-ZNC63
C 2P 30 80 MTS3-R2AC30C80 S3-ZNC80
32 MTS3-R4AC30C32 S3-TZC32
63 MTS3-R4AC30C63 S3-TZC63 5(90mm) 787
80 AC MTS3-R4AC30C80 S3-TZC80
C 2P 30
17 www.mantunsci.com www.mantunsci.com 18
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Ordering Information Technical Information
iMCB module Tripping characteristic curves
Numbers of
Number of Curve Rated Order Product Weight
Pictures Modules( 1 B-curve: (3-5) In C-curve: (5-10) In
Poles Current In (A) Code Code Unit: g
module=18mm)
S3-FB20
S3-FB32
S3-FB63
S3-FC20
S3-FC32
S3-FC63
S3-FD20
S3-FD32
S3-FD63
S3-FNB32
S3-FNB63
S3-FNB80
S3-FNC32
S3-FNC63
S3-FNC80
S3-FND32
S3-FND63
S3-FND80
MTS3-M4C63L S3-TN(L)C63
MTS3-M4C80L S3-TN(L)C80
Hardware: CPU:IntelXeonE3Storage:
8GHarddisk:above100G(SSDrcmded)
Software Platform Software: OSsystemWindows2008
Server64bit,Enviroment:JRE7(32bit), MTS3-PMS2.0 PMS2.0
Redis-x64-2.8,Mysql-5.6
19 www.mantunsci.com www.mantunsci.com 20
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Ordering Information Technical Information
iMCB module Tripping characteristic curves
Numbers of
Number of Curve Rated Order Product Weight
Pictures Modules( 1 B-curve: (3-5) In C-curve: (5-10) In
Poles Current In (A) Code Code Unit: g
module=18mm)
S3-FB20
S3-FB32
S3-FB63
S3-FC20
S3-FC32
S3-FC63
S3-FD20
S3-FD32
S3-FD63
S3-FNB32
S3-FNB63
S3-FNB80
S3-FNC32
S3-FNC63
S3-FNC80
S3-FND32
S3-FND63
S3-FND80
MTS3-M4C63L S3-TN(L)C63
MTS3-M4C80L S3-TN(L)C80
Hardware: CPU:IntelXeonE3Storage:
8GHarddisk:above100G(SSDrcmded)
Software Platform Software: OSsystemWindows2008
Server64bit,Enviroment:JRE7(32bit), MTS3-PMS2.0 PMS2.0
Redis-x64-2.8,Mysql-5.6
19 www.mantunsci.com www.mantunsci.com 20
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Magnetic Release Characteristics for iMCB Installation and Wiring Diagram
An electromagnet with plunger ensures instantaneous tripping in case of short circuit. The IEC60898 distinguishes
three different types: B, C, D Combined installation and wiring shown according to the illustrated module as below:
Ambient Temperature Power supply module is mandatory module, and installed in first place of the row. It can drive max.10pcs iMCB / iRCBO.
Standard Curve Start Status Test current Test Request Tripping time Applications
for Test
1pc iRCBO / iMCB(2,3,4 poles) used as main switch, and follows to the power supply in second place.
IEC60898
Cold 3In No trip t≤ 0.1s Only for resistive loads such as: Required quantity of iMCB /iRCBO to be installed as branch switches, followed the main switch.
B Electrical heating Communication module is also a mandatory module, and installed in last place of the row. It can drive
Cold 5In Trip t < 0.1s water heating
max.32pcs iMCB / iRCBO.
stoves
All modules are connected by connection pins in each row, and a flexible flat cable is needed to connect multi rows.
Cold 5In No trip t≤ 0.1s Usual loads such as:
C Lighting 30ºC IN IN IN IN IN IN
Cold 10In Trip t < 0.1s Socket outlets
small motor
Cold 10In No trip t≤ 0.1s Control and protection of circuits A B C N N A N B N C N A N B
D having important transient inrush
Mantunsci
Lightning Protection
o o o o o o ON -O F F
lsn 10KA
Imax 15KA
WIFI
The release is activated by a MCU unit in case of overload, the standard defines the range of release for specific PE
A B C N
S3-T30
N L N L N L N L N L
overload value
Referece ambient temperature is 30ºC
Standard Start Status Test current Test Request Tripping time Ambient Temp
T>= 1h(In<=63A)
PE A B C N N A N B N C N A N B
Cold 1.13In No Trip
T>=2h(In>63A) OUT OUT OUT OUT OUT OUT
T<1h(In<=63A)
IEC60898 Hot 1.45In Trip 30ºC
T<<2h(In>63A)
1s<t<60s(In<=32A)
Cold 2.55In Trip
1s<t<120s(In>32A)
Screw size Rated torque Ultimate torque National standard Hard line Cord or hoop terminal
Type AC : For which tripping is ensured for residual 30mA-additional protection agains direct contact. 1~25 2.5 Nm 5.1 Nm 2.0 Nm 1-25mm
2
1-16mm
2
sinusoidal alternating currents, whether suddenly 100mA- Co-ordinated with the earth system according 32~80 3.5 Nm 5.6 Nm 3.5 Nm 1-35mm 2 1-25mm 2
applied or slowly rising. to the formula <50/R, to provide protection against
Type A : For which tripping is ensured for residual indirect contacts.
sinusoidal alternating currents and residual pulsating 300mA- Protection against indirect contact, as well as
direct currents, whether suddenly applied or slowly fire harzard
rising.
14 mm
6.5 mm
21 www.mantunsci.com www.mantunsci.com 22
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Magnetic Release Characteristics for iMCB Installation and Wiring Diagram
An electromagnet with plunger ensures instantaneous tripping in case of short circuit. The IEC60898 distinguishes
three different types: B, C, D Combined installation and wiring shown according to the illustrated module as below:
Ambient Temperature Power supply module is mandatory module, and installed in first place of the row. It can drive max.10pcs iMCB / iRCBO.
Standard Curve Start Status Test current Test Request Tripping time Applications
for Test
1pc iRCBO / iMCB(2,3,4 poles) used as main switch, and follows to the power supply in second place.
IEC60898
Cold 3In No trip t≤ 0.1s Only for resistive loads such as: Required quantity of iMCB /iRCBO to be installed as branch switches, followed the main switch.
B Electrical heating Communication module is also a mandatory module, and installed in last place of the row. It can drive
Cold 5In Trip t < 0.1s water heating
max.32pcs iMCB / iRCBO.
stoves
All modules are connected by connection pins in each row, and a flexible flat cable is needed to connect multi rows.
Cold 5In No trip t≤ 0.1s Usual loads such as:
C Lighting 30ºC IN IN IN IN IN IN
Cold 10In Trip t < 0.1s Socket outlets
small motor
Cold 10In No trip t≤ 0.1s Control and protection of circuits A B C N N A N B N C N A N B
D having important transient inrush
Mantunsci
Lightning Protection
o o o o o o ON -O F F
lsn 10KA
Imax 15KA
WIFI
The release is activated by a MCU unit in case of overload, the standard defines the range of release for specific PE
A B C N
S3-T30
N L N L N L N L N L
overload value
Referece ambient temperature is 30ºC
Standard Start Status Test current Test Request Tripping time Ambient Temp
T>= 1h(In<=63A)
PE A B C N N A N B N C N A N B
Cold 1.13In No Trip
T>=2h(In>63A) OUT OUT OUT OUT OUT OUT
T<1h(In<=63A)
IEC60898 Hot 1.45In Trip 30ºC
T<<2h(In>63A)
1s<t<60s(In<=32A)
Cold 2.55In Trip
1s<t<120s(In>32A)
Screw size Rated torque Ultimate torque National standard Hard line Cord or hoop terminal
Type AC : For which tripping is ensured for residual 30mA-additional protection agains direct contact. 1~25 2.5 Nm 5.1 Nm 2.0 Nm 1-25mm
2
1-16mm
2
sinusoidal alternating currents, whether suddenly 100mA- Co-ordinated with the earth system according 32~80 3.5 Nm 5.6 Nm 3.5 Nm 1-35mm 2 1-25mm 2
applied or slowly rising. to the formula <50/R, to provide protection against
Type A : For which tripping is ensured for residual indirect contacts.
sinusoidal alternating currents and residual pulsating 300mA- Protection against indirect contact, as well as
direct currents, whether suddenly applied or slowly fire harzard
rising.
14 mm
6.5 mm
21 www.mantunsci.com www.mantunsci.com 22
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Outline and Installation Dimensions Outline and Installation Dimensions
ON/OFF
ON/OFF
Alarm light
Handle Alarm light
Handle
Indicator
ON/OFF
Alarm light
Earthleakage
TEST button
Data port
Data port
Rail clip
70mm
54mm
70mm
27mm
50mm
50mm
94mm 45mm
94mm 45mm
iRCBO 4P iMCB 2P N in L in
ON/OFF
Alarm light
ON/OFF
Handle Alarm light
Handle
Indicator
Earthleakage
TEST button Indicator
Data port
Data port
Rail clip
70mm
45mm
50mm
94mm 45mm
23 www.mantunsci.com www.mantunsci.com 24
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Outline and Installation Dimensions Outline and Installation Dimensions
ON/OFF
ON/OFF
Alarm light
Handle Alarm light
Handle
Indicator
ON/OFF
Alarm light
Earthleakage
TEST button
Data port
Data port
Rail clip
70mm
54mm
70mm
27mm
50mm
50mm
94mm 45mm
94mm 45mm
iRCBO 4P iMCB 2P N in L in
ON/OFF
Alarm light
ON/OFF
Handle Alarm light
Handle
Indicator
Earthleakage
TEST button Indicator
Data port
Data port
Rail clip
70mm
45mm
50mm
94mm 45mm
23 www.mantunsci.com www.mantunsci.com 24
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Outline and Installation Dimensions Outline and Installation Dimensions
iMCB 3P iMCB 1P
L1 in L2 in L3 in
70mm
18mm
50mm
ON/OFF
UART indicator
Alarm light
Handle Communication
indicator
ON/OFF
Shift to hotspot
Indicator & reset 94mm 45mm
Data port
Data
据 port
口
DIN rail clip
Rail clip
70mm
72mm
50mm
70mm
N in L in
36mm
50mm
94mm 45mm
L1 in L2 in L3 in N in Indicator
DC output
Data port
Earth Line
ON/OFF
Alarm light DIN rail clip
Handle
Indicator
Data port
Rail clip
90mm 70mm
50mm
94mm 45mm
25 www.mantunsci.com www.mantunsci.com 26
Smart Electric Safety Supervision Smart Electric Safety Supervision
and Power Management System and Power Management System
Outline and Installation Dimensions Outline and Installation Dimensions
iMCB 3P iMCB 1P
L1 in L2 in L3 in
70mm
18mm
50mm
ON/OFF
UART indicator
Alarm light
Handle Communication
indicator
ON/OFF
Shift to hotspot
Indicator & reset 94mm 45mm
Data port
Data
据 port
口
DIN rail clip
Rail clip
70mm
72mm
50mm
70mm
N in L in
36mm
50mm
94mm 45mm
L1 in L2 in L3 in N in Indicator
DC output
Data port
Earth Line
ON/OFF
Alarm light DIN rail clip
Handle
Indicator
Data port
Rail clip
90mm 70mm
50mm
94mm 45mm
25 www.mantunsci.com www.mantunsci.com 26
Note
Note
Smart Electric Safety Supervision
And Power Management System
MTS3
iOS Android