P-9
9901A Micro Printer - Pan
nel Printer fo
or GST200
P-9
9930-TCPIP RS232 Communic
cation Board for Commun
nication to NPORT
P-9
9930-MB MODB
BUS Protoco
ol RS232 Communication
n Board
NP
PORT 5230 NPOR
RT5230 RS2
232 to TCPIP
P Converter
Other Panel Ac
ccessoriies
Passivve LCD Rep
peater. Comp
patible with G
GST100, GST
T200,
GS
ST852RP
GST55000W, GST5000F and GST5000
G
Netwoork Active Re
epeater with Full Control,, Semi-Flush
h or Wall
NR
RP01 Mounting, Includes RS485 Cla ass A Network Card. Com mpatible
with GST100,
G GSTT200, GST5000, IFP8. (L LPCB & UL Pending)
P
Graph
hic Repeaterr Panel, 99 Z
Zone/Device A
Alarm Indica
ation with
GS
ST8903
No Fa
ascia - Deale
er to Build
T-9
9911 80 Wa
ay, Surface Mount
M
Portab
ble Programming Tool foor Addressing
g, Presetting and
P-9
9910B
Testin
ng of Addressable Device
es
SOFTW
WARE
Intellig
gent Dete
ectors
Comm mon Detectorr Base for Adddressable & Convention
nal
DZ
Z-03
Detecctors (Certific
cated by LPC
CB)
Intellig
gent Combined Optical Smoke, Fixed Tempe erature and
I-9101 Rate of Rise He eat Detecto
or, Drift Commpensation, Sensitivity
Adjustment, 8 Bit Processor w with Remote IIndicator Outtput.
Intellig
gent Optica al Detector, Drift Com mpensation, Sensitivity
I-9102 Adjustment, 8 Bit B Processo or with Rem mote Indica ator Output
(Certifficated by LP
PCB)
Intellig
gent Fixed Temperature
T and Rate of Rise Heat Detector,
D 8
I-9103 Bit Proocessor withh Remote Ind
dicator Outpuut (Certificate
ed by
LPCB B)
I-9104 Intellig
gent Ultra-Violet Flame Detector
D
Gas Detector
D LPGG Low Pressu
ure Gas, 24V
VDC Powere
ed, with
I-9602LW-LPG
G
Local Buzzer Alarm
Gas Detector
D Coa
al Gas, 24VD
DC Powered, with Local Buzzer
B
I-9602LW-CG
Alarm
m
DP
P9100 Duct P
Probe with Adjustable
A Tu
ubes excludin
ng Base & Detector
D
Programmable Ala
arm Indicatio
on Linked to Any One or Group of
I-9314
Devicces.
Intellig
gent Man
nual Call Points
Semi Flush Mountting Re-setta able (Non-Breeaking Glass s), Supplied
DI--9204 with Special
S Rese
et Tool - Com
mpatible with both I & DI Series
S
(Certiffied by LPCB
B)
Anti Tamper
T Secuurity Cover - Protects call point from accidental
a
DC
C-92FC
operaation, suitable
e for DI & DC
C 9204 Manu ual Call Pointts
DC
C-92WPB IP66 W
Water Box fo
or DI & DC 9204 Manual Call Point
Intellig
gent Mod
dules Plu
us Isolators
I-9300 Single
e Input Modu
ule (Certificatted by LPCB
B) - Loop Pow
wered
Single
e Input/Outpu
ut Module (C
Certificated by LPCB) - Lo
oop
DI--9301
Powered
I-9303 Dual-w
way Input/Ou
utput Module
e, 24VDC req
quired
Individ
dual Control for 2 Dry-Coontact Outputs and 1-16 Inputs,
DI--9309
24VDC required, without
w casee
Addreessable Soun nder Circuit Control
C Moduule, Alert and
d
I-9308
Evacu uation Contro
ol, 24VDC reequired
C-9
9503 Zonal Short Circuit Loop Isolattor, (Certifica
ated by LPCB
B)
C-9
9504 Base Mounted Iso
olator (Certificated by LPC
CB)
C-9
9302 AC Co
ontrol Relay for Power Sw
witching
Interfa
ace Module for
f Fireman'ss Switch, Ena
abling Cable
e Monitoring
C-9
9302C
and Signal
S Confirm
mation
B-9
9310 Surfacce Mount Ba
ack box for Modules
M
Intellig
gent Sou
unders
New Addressable
A Loop Powerred Combine
ed Base Mou unt
I-9406 Sandw wich Type Soounder and Strobe,
S Multii Tone, 80 DB@1M for I
Seriess Detectors (LPCB
( Pending)
I-9402 Addre
essable Base
e Mount Sounder
Addre
essable Com mbined Soundder and Strob
be, Loop Pow
wered and
I-9403
24VDC, (Certificatted by LPCB
B)
I-9404 Addre
essable Soun
nder, 24VDC
C required (C
Certificated by
y LPCB)
Power Supplies
3A 24VDC Intelligent PSU, Display shows DC Output Voltage
PSU24-3 and Load Current, Fully Monitored with Self test Facilities,
Excluding Batteries
1 2
HOLE
LOOP IN LOOP OUT
+
− −
4
3
+
−
C−9314P
Notes:
1. DZ-03 detector base
2. I-9102 and I-9103 available with built-in remote indicator output
3. I-9101 and I-9104 are without remote indicator output
4. To fix, point the detector in the base by the mark-line and secure the detector in that
position by rotating it clockwise until it reaches the next mark line.
1 2
LOOP OUT
LOOP IN
+
− −
4 3
+
−
C−9314P
Notes:
1. DB-01 detector base
2. DI-9102 and DI-9103 available with built-in remote indicator output
3. DI-9101 is without remote indicator output
4. To fix, point the detector in the base by the mark-line and secure the detector in that
position by rotating it clockwise until it reaches the next mark line.
MODULES
I-9300 INPUT MODULE- LOOP POWERED
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1
9 10 11 12 13 14 15 16
9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16 G I1 Z1 Z2
G I1 Z1 Z2 G I1 Z1 Z2
INPUT N/O
INPUT N/O INPUT N/C
Ex. flow switch Ex. zone valve Parallel 4.7kohms
Cable Monitoring
V+ G COM NO NC V+ G COM NO NC
8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1
9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16
D1 D2 G I1 Z1 Z2 D1 D2 G I1 Z1 Z2
24 VDC PSU
24 VDC PSU
V+ G COM NO NC
8 7 6 5 4 3 2 1 V+ G COM NO NC
8 7 6 5 4 3 2 1
9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16
D1 D2 G I1 Z1 Z2 D1 D2 G I1 Z1 Z2
V+ V−COM NO NC
V+ V−COM NO NC 8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
9 10 11 12 13 14 15 16
9 10 11 12 13 14 15 16 V+ V− G I1 Z1 Z2
V+ V− G I1 Z1 Z2
V+ V−COM NO NC
8 7 6 5 4 3 2 1 V+ V−COM NO NC
8 7 6 5 4 3 2 1
9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16
V+ V− G I1 Z1 Z2 V+ V− G I1 Z1 Z2
9 10 11 12 13 14 15 16
D1 D2 G I1 I2 Z1 Z2
9 10 11 12 13 14 15 16
D1 D2 G I1 Z1 Z2
24 VDC PSU
24 VDC PSU
4.7KOHMS
N/O
I1 G 4.7KOHMS
N /O
INPUT 1−16
N01
COM1 OUTPUT 1
NC1
24 VDC PSU
I-9305 I-9308
TO SPEAKER
9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16
V+ V− G I1 Z1 Z2 D1 D2 Z1 Z2
24 VDC
Gas Detector
I-9602LW
24 VDC PSU
+ − + −
Z1 Z2 D1 D2
+ −
K1 K2 V+ V−
− + − +
+ − + −
K1 K2 Z1 Z2
Remote N/O
System LOOP IN LOOP OUT
470 OHMS
9 10 11 12 13 14 15 16
D1 D2 Z1 Z2 9 10 11 12 13 14 15 16
D1 D2 Z1 Z2
LINE ISOLATOR
C-9503 C-9504
LOOP OUT
1 2
OUT+ OUT−
IN−
8 7 6 5 4 3 2 1 OUT
−
HOLE
LOOP OUT LOOP IN
OUT
9 10 11 12 13 14 15 16
IN+ IN− Z1 Z2 IN+
+
4
3 Remote
Indicator
LOOP IN
C-9302
1 2
D1 D2 Z1 Z2
+
24VDC −
+
LOOP IN
− HOLE
LOOP OUT
LOOP IN LOOP OUT
+ +
− −
4 6 5 3
I-9403, I-9404
24VDC PSU
I-9407
+
−
D1
D1 D2
D2
8 9 G
8 9 G 7
7
10 6 10
6
K1 K1
5 1 5 1
4 K1 4 K1
2 S 2
S 3 3
Z2 Z1 Z2 Z1
LOOP IN K2 LOOP IN K2
LOOP OUT LOOP OUT
+ +
+ +
− − − −
GND
LED #100
HL65 HL66 HL67 HL68 HL5 HL6 HL7 HL8 HL9 HL10 HL11 HL12 HL13 HL14 HL15 HL16 HL17 HL18 HL19 HL20 HL21 HL22 HL23 HL24 HL25 HL26 HL27 HL28 HL29 HL30 HL31 HL96
+ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +
HL1 HL2 HL3 HL4 HL5 HL6 HL7 HL8 HL9 HL10 HL11 HL12 HL13 HL14 HL15 HL16 HL17 HL18 HL19 HL20 HL21 HL22 HL23 HL24 HL25 HL26 HL27 HL28 HL29 HL30 HL31 HL64
+ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +
HL1 HL2 HL3 HL4 HL5 HL6 HL7 HL8 HL9 HL10 HL11 HL12 HL13 HL14 HL15 HL16 HL17 HL18 HL19 HL20 HL21 HL22 HL23 HL24 HL25 HL26 HL27 HL28 HL29 HL30 HL31 HL32
+ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +
SPEAKER
RED BLACK
SILENCE BUTTON
MUTE SK1
CHECK
SELF SK2 XS3 D2
TEST XS4
Buzzer
MUTE _ +
HL3
ALARM HL2
WORK HL1
XS1
WARNING:
1.TURN OFF THE PANEL
2.REMOVE ALL THE JUMPER OF X1
3.CONNECT THE PS/2 CONNECTOR OF HANDHELD
PROGRAMMER TO TERMINAL XS1
4 AFTER THE PROGRAMMED REMOVE THE
PS/2 CABLE AND RETURN THE JUMPER OF X1
AND THEN TURN ON
FAULT OUTPUT
24V B A
X1 GNDN
1 2 3 4 OFF ON
FIELD DEVICE PROGRAMMER F7.820.919.a
24VDC B A
PSU TO FACP
Networked Wiring Details
Class A Network/GST-NRP01
P−9945A P−9940A
A2 A1
I− O− A2 A1
B2 GST IFP8 B1 GST 200/2
I+ O+ B2 B1
P−9941A
P−9942A Built−in network card
B1 B2 B1 B2
GST5000 GST−NRP01
A1 A2 A1 A2
MAXIMUM DISTANCE 1.2 KM
GSTIFP8 GST200-2
Note: Connect the network card (P-9940A) in Extend Port from the main
baord behind the door through flat ribbon,
Note:Insert the network card (P-9945A) on Loop Board XS3 and
XS10 and wired in Loop 10 terminal
+ + +
Warning!! For A1,B1,A2,B2
1.2Km max distance between two panels terminal arrangement
D1
HL3 HL2 HL1
A1 please refer to the PCB labelled
O-
A2
LOOP 10
B1
B2
O+
XT1
XT10
Actual wiring
A2 A1
I-
D5 D4
B1
B2
I+
O-
LOOP 9
O+
XT9
XS1
F7.820.1007
GST5000
Note:Insert the network card (P-9941A) on Comm Card and wired in
N-485 terminal
GST NRP01
Network Repeater 8
9 01
2 8
9 01
2 8
9 01
2
A1 B1 A2 B2 A3 B3 B4 A4
7 3 7 3 7 3
65 4 65 4 65 4
GND
T 485
SET ROTARY
SET ROTARY
SET ROTARY
+5V
ADDRESS 2
ADDRESS 3
ADDRESS 1
Actual wiring
B1
XT8
B1 A1
N 485
A1 B2
XT6
B2 A2
MAIN CARD
NETWORK CARD OR
D1 terminal arrangement
ZX2
GND
CD
XT2
+5V
SAC
SBAT
B
AGND
485
XT1
+24V
A
A A A A
GST200 GST100 GST5000W GST5000F
B B B B
GSTIFP8 GST200-2
Note: Connect the network card (P-9940A) in Extend Port from the main
baord behind the door through flat ribbon,
Note:Insert the network card (P-9945A) on Loop Board XS3 and
XS10 and wired in Loop 10 terminal
+ + +
Warning!! For A1,B1,A2,B2
terminal arrangement HL3 HL2 HL1
D1
A1 please refer to the PCB labelled
O-
A2
LOOP 10
B1
B2
O+
XT1
XT10
Actual wiring
A2 A1
I-
D5 D4
B1
B2
I+
O-
LOOP 9
O+
XT9
XS1
F7.820.1007
GST5000
Note:Insert the network card (P-9941A) on Comm Card and wired in
N-485 terminal
GST NRP01
Network Repeater 8
9 01
2 8
9 01
2 8
9 01
2
A1 B1 A2 B2 A3 B3 B4 A4
7 3 7 3 7 3
654 65 4 654
GND
T 485
SET ROTARY
SET ROTARY
SET ROTARY
+5V
ADDRESS 2
ADDRESS 3
ADDRESS 1
Actual wiring
B1
XT8
B1 A1
N 485
A1 B2
XT6
B2 A2
MAIN CARD
NETWORK CARD OR
D1 terminal arrangement
ZX2
GND
CD
XT2
+5V
SAC
SBAT
B
AGND
485
XT1
+24V
A
Checking Parameter
• Turn on
• Press the “Clear”
• Press the “Test” and then scroll using the “UP and Down” buttons
Device parameters sequence:
(For Detector & Input Module) (For Sounders)
TEST – Address Test- Address
UP – Sensitivity/Parameter UP- Sensitivity/Parameter
UP – Device Type UP - Factory
UP – Factory code UP – Device Code (For Sounder)
Addressing of devices
• Turn on the handheld programmer
• Press the “Clear”
• Enter the address and then press the “Program”
(Display P-means confirm programmed or E-meaning error)
Shifting Sensitivity of the detectors and input module parameter
• Turn on
• Press the “Clear”
• Press the “4,5,6” and then the “Clear”
• Press the “Function” and then the “3” (notice “-“ appears on the display)
• Enter Sensitivity Level or Parameter and then the “Program”
(Display P-means confirm programmed or E-meaning error)
1. 3 Sensitivity Level I-9101, I-9102, I-9103, and I-9104
Level 1 highest sensitivity (Default Setting)
Level 2 Standard sensitivity
Level 3 Lowest Sensitivity
(Optical Smoke: L1-0.10dB/m, L2-0.33dB/m, L3-0.56dB/m)
(Fixed Temp: L1-54°C, L2-62°C, L3-70°C)
(Flame: L1-25metres, L2-17metres, L3-12metres)
Table 2
• Turn on
• Press the “Clear”
• Press the “4,5,6” and then the “Clear”
• Press the “Function” and then the “4” (notice “-“ appears on the display)
• Enter device code and then the “Program”
(Display P-means confirm programmed or E-meaning error)
Addressing of Beam
• Turn on, press the “2,5,9” then the “Function”,
• Input the new address and then press the “Program”
(Display P-means confirm programmed or E-meaning error)
Loop Capacity
Cable Recommendation
Loop Capacity
1. 242 addresses per loop
2. Consider that zone indication, 3 programmable alarm outputs and loop monitoring have an address.(GST5000
Only)
3. Consider 20% spare addresses per loop for future expansion within the loop
4. Limitation per loop
I-9402 = 30 per loop
I-9406 = 30 per loop or (44 Max 80 devices)
I-9407 = 25 per loop
I-9300 = 100 per loop
DI-9301 = 50 per loop
C-9503 = 10 per loop
C-9504 = 20 per loop
Zone Capacity G
GST200-2
2/1 or GS
ST200-2/2
2
Instaallation of th
he panel should be carrieed out by trained personn nel only. Thee electronic ccomponents inside the p
panel
are vvulnerable too damage byy electrostatic dischargess. It is recom
mmended to w wear a wrist strap design
ned to prevent the
buil‐‐up of static charges whithin the boddy, before haandling any eelectronic circuit boards.
HL1 HL2
+ +
Serial port
RS 232 CARD XS2
(Optional) D1
USB port
XS3
XS1
F7.820.913
Network CARD + + +
P-9940A D1
HL3 HL2 HL1
B2 B1
TO/FROM A2 A1
XT1
OTHER FACP B1 B2
D5 D4
A1 A2
1.2Km bet two panels
XS1
F7.820.1007
Main Control Board
F7.820.1125 XS2
XS13
A SPEAKER
+
Loop 2 CARD
HL2
XS12
ZO+ ZO-
GST2002 Basic Wiring Diagram
B
XT1
01 02
EXTENDED PORT
(GS200/2/1-Optional)
LOO P 2
XS7
Z1 Z2
SPEAKER
Loop 2 CARD
ZI+
XT3
D17
(GS200/2/2-Supplied)
ZI-
HL1 HL3
D4
24V- SK1
BAT Fault
AC Fault
5V
F7.820.828V1
GND
LED PORT
A
R EPEATER
XS6 BACK
R S 485
B
XS11 LIGHT
+
R EP EA TER
A
XT10
A
N ET WO RK
XT11
RS 485
B
B
N ET WO RK
Loop 1 Board
A
+
LO O P OUT
XT9
XT4
LOOP BUS
Z+ B
_
XT2
D2 D1 Z-
+
XT13
O UTPU T
A LA RM
+
LO O P O UT
XT5
FIRE
_
Terminal Board
OU TPUT
+
LO OP OUT
F.E .P.
XT6
HL HL
(Supplied)
HL HL HL HL HL HL
_
+ +
SOU N DER
O UTPUT
+ + + + + +
C IRC U IT
+
LO O P OUT
HL HL
XT7
HL HL HL HL HL HL
GND +24V +24V GND +5V GND GND +5V
_
+ + + + + + + +
Power Supply Unit
HL HL
HL HL HL HL HL HL
+ + + + + + + +
HL HL
HL HL HL HL HL HL
NC C OM NO
F AU LT O UTPU T
X4 + +
+ + + + + +
XT8
HL HL
HL HL HL HL HL HL
HL5
+ + + + + + + +
C LA SS C HANGE
HL HL
HL HL HL HL HL HL
XT3
+ + + + + + + +
HL HL
HL HL HL HL HL HL
F1
+ + + + + + + +
X5 HL2 HL HL HL HL
HL HL
HL HL
X6 X1
+ + + + + + + +
F2 HL HL GND +5V
HL HL HL HL HL HL
HL3
+ + + + + + + +
X7 X2
F3
HL4
EARTH
X3
X8
AC Input
32 Manual Intervention zone and indicator board Printer
F7.820.829bV1
Fuse
L G N
FUSE
OFF ON OFF ON
CHARGER
+
AC Filter
HL1
FAULT
_ BAT + 0 I 0 I AC 16-30V
AC2 20V
2A
24V Batteries
Step-down Transformer
- + - +
12V 12V
Zone Capacity-60 Zones
Output to Repeater or Mimic Panel F7.820.828V1
Monitored
Terminal Details
A
REPEATER
XT12
RS-485 (XT11, XT12): To be connected
RS 485
B
B
with repeater panel and FACP
REPEATER
A
XT10
A
NETWORK
No connection
XT11
Refers to Optional
RS 485
Network Board
B
B
can connect with up to 235 addressable
NETWORK
A
+
LOOP OUT
XT9
Loop Out (Out to First Device)
devices.
XT4
LOOP BUS
Monitored
Z+ B
_
XT1
LOOP IN
_
XT2
Loop In (In From Last Device)
default outputs when there is fire alarm;
D2 D1 Z-
+
Address 242
Standby Volatge:-9 to -11VDC
XT13
OUTPUT
ALARM
+
LOOP OUT
XT5
+
FIRE
4.7Kohms
_
Output Device with
Sounder with
fitted diode built-in diode
OUTPUT
Monitored
+
LOOP OUT
F.E.P.
OR
XT6
+
+
4.7Kohms
SOUNDER
OUTPUT
CIRCUIT
+
LOOP OUT
XT7
+
4.7Kohms
EOL
LOOP BUS (XT2, XT4): Loop Out is the
_
NC COM NO
X4
XT8
loop fault.
XT3
F.P.E. OUTPUT, SOUNDER CIRCUIT OUTPUT and FIRE ALARM OUTPUT can provide three output modes, which are 24VDC voltage output,
normally open output and normally closed output. You can set up the three modes through Pin X1~X7. See more details in Table 1.
Table 1
(Note: Turn off the Panel before setting)
Note:
GST200-2 Output Set-up
1. Default Outputs
a. All 3 outputs active immediately at fire events
b. Equation loop sounder will not activate (only same zone) excluding modules
c. Sounder Circuit can be silenced only.
2. C & E Outputs ( Cause and Effect Equation)
a. Fire Outputs active immediately at fire events
b. FPE – Device type No. 65 and zone (000) should be defined, Delay time is not possible
c. Sounder Circuit‐ Device type No. 55 and zone (000) should be defined, Delay time is possible. Can
be silence
Procedures to Commission GST 200/2/2
1. Program a unique address number for each device using handheld programmer (P-9910B) according to
the project layout before placing from the terminal base.
2. Connect the loop within the panel as follows: Loop OUT + to Loop IN+/ Loop OUT- to Loop IN- .
3. Turn on the panel and perform an auto learn/registration as follows:
• Press “System” Enter the password ____________ (Commissioning password)
• Press “Enter”
• Press “SK1 button” behind the door.
(Note: procedure should be done within 25 seconds otherwise the control panel will initialize the
normal panel reset)
4. Confirm the registered device address using browsing menu as follows:
• Press “Browse” Enter the password 11111111 (Default password)
• Press button number “Loop Devices”
• Select the loop number and press Enter
5. Download the database to the panel, it required to connect the download card (P-9930) and also must be
registered from the panel. (See Upload/Download Procedures on page 68)
6. View the downloaded database using the User Keypad Menu (Device Detailed, Zone, Equation)
7. Test the system
To ensure the system commissioning runs as smoothly as possible, the following points must be observed.
Trouble Shooting
1. Loop SW – loop wiring problem, check the following (open circuit, short circuit between cores, cores to
screen or cores to building earth.) and make sure the loop is not exceed to 1.2Km.
2. CRT Fault – Download card is not communicating with the computer, turn-off the panel and removed the
card after commissioned the system.
3. System cannot register the device/s
a. Check the panel if it set to Commissioning Mode
b. If the cable exceed to 1.2Km the succeeding devices will not register (Loop In is the standby
voltage)
c. Check the device wiring and terminal polarity
d. Check the address on the device
e. Subsequent to C and D isolate the loop filter by connecting one device directly to the loop card
output terminal (XT1) of the Terminal board and try to register again.
f. Subsequent to E, and then still not registering, replace the main card.
GST2002/2 User Keypad Menu
Operator password: 11111111
Manager password: 11111111
BROWSE
1 Loop Devices: View number of devices per loop and detailed provided with each device
2 Zone Devices: View the total number of Input devices per zone
3 Group Device: View the total number of Output devices per zone
4 In Test Mode Zones
5 COM Devices: View the number of Control Panel and Repeater panel connected in the system
6 Access: Control switch and zone indicator detailed.
7 Browsing C&E: Sequence of operation detailed
ACK/MUTE
Acknowledge the alarm condition / Silence the FACP sounder
ESC
Canceling or exiting operation menu, or enabling the FACP to displaying information of the highest
priority
ENTER
Confirmation of input
Output Condition Address Alarm Delay Time-Enable Stop – via Silence Button
Fire Alarm Output Output 1 242 Immediate Immediate NO
FPE FPE 241 Immediate Immediate NO
Sounder Circuit Sounder A 240 Immediate On after 30 sec Yes
On C&E MODE
Programmed and Cards
Power
Up 220/230 (+10%, -15%) 50/60Hz
Battery fault: voltage drop to 19 Vdc, internal resistance more than 1ohm
43
List of Spare Parts
GST200 Fault Information