Sei sulla pagina 1di 1

26/10/2019 Checks for Limiting Parameters (Pile Cap: BS 8110)

Home / Reference Guides / Concrete Design - BS 8110 / Pile Cap Design to BS 8110 / Checks for Limiting Parameters (Pile Cap: BS 8110)

Checks for Limiting Parameters (Pile Cap: BS 8110)


Limiting reinforcement parameters are specified in Design Options >  Foundations >  Isolated Foundations >
Reinforcement Layout 
Check for distance of pile cap overhang
Check pile edge distance “e” for pile “i” in a pile group for both directions:
The check passes if:
If min ei  > emin,user 

Check for minimum pile spacing


Check centre to centre spacing “s” between piles “i” and “j” in a pile group:
The check passes if:
If sij  > min(smin , smin,user)
where
smin,user = user input
smin = perimeter of the pile for non circular friction piles
smin = 3*diameter for circular friction piles
smin = 2*least width of the pile for end bearing piles

Check for maximum pile spacing


Check centre to centre maximum spacing “s” between piles “i” and “j” in a pile group:
The check passes if:
If sij < smax,user
smax,user = user input

Other checks
The remaining checks are identical to those for pad bases.
See: Pad Base and Strip Footing Design - Checks for Limiting Parameters.
 
Related topics
• Pile Capacity
• Design for Bending
• Shear Design
• Punching Shear Design
 
 
 

https://teklastructuraldesigner.support.tekla.com/webhelps/tsd/2018/All_Codes/Reference_Guides/BS_Concrete_Member_Design_Handbook/Pile_Cap_Design/… 1/1