ALARM ANNUNCIATORS Low power, super bright White LEDs Choice of 3 window SIZES and 6 window COIOUTS EMI/EMC ‘compliant Space saving due to lower depth Wide fault 4 Input range Outputs RS485 Modbus communication interface Features + Standard models available from 2 to 32 windows + Choice of 3 window sizes (Small, Medium, Large) + Available in six window colours — Red, Yellow, Blue, Green, Amber and White + Optically isolated fault inputs with wide fault input voltage range (12V - 240V AC/DC +/-10%) + Field selection for NO / NC fault input contacts, grouping of alarms, window size configuration + Space saving due to lower depth of only 100mm ‘+ Integral push buttons for Test, Acknowledge, Mute and Reset operations + Four SPDT relay outputs (2 for grouping, 1 for external hooter,1 for ring back sequence) + Low power, super bright White LEDs for window illumination + Replaceable windows and window legends + Low power consumption of 0.5 W per window + 6 Field selectable operation sequences as per ISA standard ‘+ Integral buzzer for audible alarm output of 90 dB + Communication interface with RS485 Modbus RTU protocol + EMI/EMC compliant as per IEC standards Working Principle Whenever there is a change of input contacts from Normally Open to Close or from Normally Close to Open position, annunciator changes from rest condition to alarm condition Hence there is an immediate recognition of fault input which will have a corresponding visual and audio alarm as per the particular selected program sequence. The base unit of alarm annunciator has four programmable keys for Mute, Acknowledge, Reset & Test function. On pressing the Mute key the internal buzzer can be deactivated. Acknowledge key is used to accept the fault condition, Reset key enables to reset the alarm annunciator to its default state and Test key helps to perform the complete test of the system. Technical Specifications Parameters Supply Voltage (@) ‘Supply Variation Supply Frequency Power Consumption LED Indication (Green) No. OF Windows Window Size Window Colour Mumination Fault input Signal Fault input Voltage sponse Time ‘Sean Time Flash Rate Terminal ‘Output Relay Contact (16/0) Relay Contact Rating ‘Audible Alarm Output Facia Type ‘Alarm Sequences Push Button Controls Communication Port, ‘Operating Temperature ‘Storage Temperature Humic Weight (packed) Approx Mounting Type Terminal Connection Communication Port Centiication Degree of Protection EMI EMC Compliance Harmonie Current Emissions ESD, Radiated Susceptibility Electrical Fast Transient Surge Conducted Susceptibility Voltage Dips ana Interupons(AC) Conducted Emission Radiated Emssion ‘Safety Compliance “Test Voltage Between VP and O1P Impulse Votlage Between iP ‘And O1P Single Fault Test Insulation Resistance Leakage Current Poluton Degree Environmental Compliance Cold Heat Dry Heat Vibration 110-240 VACIDC 20% to +10% (of) 50160 Hz 0.5 W per window ON- Healthy Blinking - Ertor (Wrong window configuration OR Number of windows > Number of fault inputs) 2 0 32 windows in diferent configurations ‘Small. 34.3x31. 55mm, Medium: 68.8x31.55mm, Large: 68 8:63.3mm Red, Yellow, Blue, Green, Amber and White Low power super bright white LEDs Potential free (NOINC Feld selectable) Internal: 12V DC / Extemal: 12V ~ 240V ACID (w-10%) 130 msee 100 msec 4) Fast flash ~ 0.5 Sec ON /0.5 Sec OFF (60 flashes/Min) 2) Slow lash —0.5 See ON / 1.5 Sec OFF (30 lashesiMin) Pluggable terminal blocks for conductor up o 2.5mm? 4 Relays (2 for grouping + 1 for extemal hooter + "for ring back sequence) NO- 5A/NC - 3A @250V AC & NO - 5A/NC~ 3A @30V DC (resistive) 90.48 Individual window lan, replaceable from front [As por ISA standard (Field configurable) 4) Manual Reset (M-1) | 2)Auto Reset (A-1) 3)Ring Back (R-1-12) 4) Aulo Reset with No lack in (A-1-4) '5) Manual reset st outwith no subsequent alarm flashing and silence push button (F2M-1) 68) Auto reset first outwith no subsequent alarm flashing an silence push button (F2A-1) Integral Push buttons for Test, Mute, Acknowledge and Reset functions. Provision of output connections for remote access of push buttons Computer intrface with R485 Modbus RTU protocol HOC to +55°C AAC to 460°C 95% RH 1D= 580 g, 20= 960 9, 30= 1320 g, 4D= 1680 9 Panel Mounting For Output Relay, Fault input, Remote Keys Power Supply Connection: AWG 28 to 12, Pht.g3.Smm, Torque 0.SNmi4.5I9 in) For intemal 12V supply, RSAB5 Connection: AWG 28 to 16, Fla-@2.Snm, Torque 0.2Nm(t.771.in) RS 45 communication with Modbus RTU i} Front panel IP40, Rear panel IP20 ec 6100032 Ciass A IEC 61000-4-2 Lovell Class A EC 61000-4-3 Level Il Class A EC 61000-4-4 Leve! Ill (Power Supply and Input Signal wih external supply), EG 61000-4-4 Leval Ill (Capacitive coupled on input Signal and Remote keys wih internal 12V supply), EC 61000-4-4 Level Ii (Capacitive couplod on Communication) TEC 61000-4-5 Level IV (Power suply and input Signal with external supply) TEC 61000-4-8 Level Il Class A IEC81000-4-11 Al Vl Lovel Pass CISPR 11/ CISPR 14-1 Class A CISPR 11 / CISPR 14-1 Class A EC 60255-5, 2.5K, S0He, *Min IEC 60255-5, 5k, 7.250Us, 0.51 lec 6r010-1 UL 808 > 50 ka UL S08 <3.5 ma, t IEC 60088241 TEC 60088.2.2 TEC 60088-2.5, 10 to SSH —_—_— Mounting Dimensions (mm) 3D 4D Connection Diagram Push Button Connections Fault Input Gonnetions Output Relay Connections: sh Button Cone m7 TT nrtrenn2.cn Ta} a FP ie. oe TJ Rete or coup #61) nex | 5's ee SY | oly nace =| genee em =~ Saas a mo) <7 teeta Ester Supply: TAI ACD 10%) ry (for max 32 windows) Front Panel E BED s. For inserting legends, please remove the specife window by inserting a fat screwdriver tip {ss than Sm) into the window ‘cover groove and lever up sight 2. To separate the window and \window housing, insert the tp of a flat screwdriver into one of the spooves on either othe sides os @ Window — @) Window Housing ‘shown nthe picture, Once fnshe \with inserting the legend between @ Legend* © LED with Reflector difesor ard window, the whole ‘assembly can be press fied into © Diffusor the original position *Legend templates in Microsoft Excel are available on our website: www.gicindia.com Standard Alarm Sequences : (As per ISA Standard) Alarm annunciators can be configured to operate as per one of the following standard sequences. Manual Reset : (ISA M-1) Same satan ng ease er vu on ‘ua. faints Listens tg ME Auto Reset : (ISAA-1) Taorenme Nome sun areca, | Seems vatine | tty Somes te Auto Reset with no lock in : (ISA A-1-4) Ring Back : (ISA R-1-12) — Manual reset first out with no subsequent alarm flashing and silence push button : (ISA F2M-1) j= Auto reset first out with no subsequent alarm. flashing and silence push button : (ISA F2A-1) coon nner) Wk ati se DIP Switch Setting For Sequence Selection : Faneanng) M2vetReset vet) To contour alarm 1234 5678 squeocet Aut Rose (Act j a] (A) Note Arye Ring Bac R112) Wb ya e678 | Manual reset fst out with no Considered season alarm testy sa Sha slonc posh button P21) reset yu ser | Auo eset ft ou with no ne Subsequent aor testing and silence push button (F2A-1) 12345678 Autoresetwith No Tock in (A-t-8) ————“—+ cu — Configuration and Connections Grouping Relays Ring Back Relay Hooter Relay Device ID Selection ‘Sequence Selection RS485 Connection Fuse 250 V, 5A. Power Supply DIP Switch Settings DIP SWITCH For fault contact, ‘configuration (NO J NC) To configure fault inputs ‘a8 Group 1 or Group 2 ‘To select device ID for RS485 communication z qT & eeuveuve = rH reel — +p thaw P| | Tel el @Sayparary BABAR Gea Fault Inputs ot Ne aaa BABAR Gea of > 0- [EE] roves ‘ono [=| re Group Selection NO/NC Selection Remote Keys Internal 12 VDC, 50 mA O/P SETTING 1234 5678 wee aman 12345678 eww anals: 1234 5678 uc) BEB pown(o) we @ (Sourcing) FUNCTION Each individual fault input can be selected as NO or NC. based on DIP switch position. Ifany of the DIP switch is ssot upwards then itis selected as NC fault contact and if, it is set downwards then it is selected as NO fault contact. NO contact clases to indicate alarm and NC contact opens to indicate alarm. Each individual alarm can be assigned to group 1 or {group 2 based on DIP switch position. If any of the DIP Switch is set upwards then itis selected as group 2 alarm and if is set downwards then itis selected as group 1 Device ID can be assigned from 1 to 247, Device ID represented in binary information with respect to switch position. for example, Ordering Information Cat. No. AU1D8S AU1D6SP AU2D16S Au2D14SP AU3D24S AU3D22SP AU4D32S AU4D30SP AU1D4M AU1D3MP Au2D8M AU2D7MP AU3D12M AU3D11MP AU4D16M AU4D15MP AU1D2L AU2D4L AU3D6L AU4D8L Product Size 1D 2D 3D 4D 1D 2D 3D 4D 1D 2D 3D 4D No. of Windows oo kN Window Size Small Small Small Small Medium Medium Medium Medium Large Large Large Large Keys Small Big Small Big Small Big Small Big Small Big Small Big Small Big Small Big Small Small Small Small Window Dimensions ‘Small Medium 2 Large “Live product configurator and enquiry request form available on our website: www.gicindia.com rr) [ng 2 4 oO z =) z z P4 | ig a4 a ad Note: + Innovation being a continuous process, design and specications are subject lo change without prior notice. + Users racommended to ensure the suitably of the products for intended application + GIC isnot responsible fr consequential damage out of use of its products. General Industrial Controls Private Limited 107, M..D.C., Bhosari, Pune 411026, Maharashtra, INDIA Tel. : +91 20 30680003 /04/11/31 Fax: +91 2027122574 Email: marketing@gicindia.com | sales@gicindia.com | export@gicindia.com Web : www.gicindia.com |SAS | wwsasconm.in| 201701 |

Potrebbero piacerti anche