Sei sulla pagina 1di 2

Wind Pressure on the Louvers

Basic information Ref


Bulding height H= 15.5 m
Greater Horizontal Dimension L= 126.8 m
Lesser Horizontal Dimension W= 67.7 m
Heifht of the structure z= 10.3 m
Fundamental value of the basic wind velocity vb,0 = 20 m/s

Wind Load Factor


Direction factor cdir = 1
Season factor cseason = 1

Terrain category
z0 = 0.05 Table NA.1
zmin = 2
3
Air Density ρ= 1.194 kg/m NA.2.18

Wind Load Calculation


Basic wind velocity vb = 20 m/s eq (4.1)
2
Basic velocity pressure qb = 0.2388 kN/m eq(4.10)
At Height of z
Peak Pressure
0.07
Terrain factor kr = 0.19 (z0/0.05) eq(4.5)
= 0.19
cr = krIn(z/z0)
= 1.012296
co = 1
mean velocity at a heigh z vm = cr.co.vb
= 20.24593
Characteristic peak velocity pressure, qp
Turbulence factor kI = 1 NA.2.16
Standard deviation σv = kr.vb.kl eq(4.6)
= 3.8
Turbulence intensity at height z lv(z) = σv/(vm(z)) eq(4.7)
0.187692
2
Characteristic peak velocity pressure, qp qp = [1+7.lv].1/2.ρ.vm (z) eq(4.8)
2
= 0.566218 kN/m

Cpe
h/d = 0.228951
Floor height hf = 4.3 m
2
Total loaded area A= 545.24 m

2
Because the loaded area is greater than 10m , therefore use cpe,10
Zone A cpe,10 = -1.2 Table 7.1
Zone B cpe,10 = -0.8
Zone D cpe,10 = 0.8
use cpe,10 = 0.8
2
Load pressurer on the cladding P= -0.67946 kN/m
2
= 0.7 kN/m

Potrebbero piacerti anche