System Overview
E-SLOPE OR
CONTROLLER
SET POINT
600 150 - 1400°F or 80 - 800°C 2.0 - 2.6µ Medium temperature applications for thick
plastics, rubber, textiles and metals.
700 100 - 2500°F or 50 - 2500°C 4.8 - 5.3µ Glass surface temperature in forming, bending.
tempering, annealing and sealing.
800 75 - 800°F or 25 - 400°C 7.92µ Thin films of polyester (PET) and fluorocarbon
plastics.
3G 500 - 2500°F or 250 - 1400°C 1.5 - 1.6µ Medium temperature applications, particularly
3G Fiber Optics 650 - 2500°F or 350 - 1400°C 1.5 - 1.6µ ferrous and non-ferrous metals.
3L 500 - 1800°F or 250 - 1000°C 1.00 - 1.20µ Low temperature non-ferrous metals including
or 1.5 - 1.6µ, aluminum using two-color ratio technique.
and 1.65 - 1.71µ
3R 1300 - 6500°F or 700 - 3500°C 0.7 - 1.08 and 1.08µ For difficult high temperature processes such
3R Fiber Optic 1300 - 6500°F or 700 - 3500°C 0.7 - 1.08 and 1.08µ as molten metal, wire rod, vacuum furnaces
and kilns using two-color ratio technique.
2
Modline 3 Catalog
Sensors
The Modline 3 system offers you the widest
choice of non-contact infrared sensors to
match any process. Modline 3 sensors
offer sophisticated single lens reflex (SLR)
focusing, that can view spots as small as
0.012 inches (0.3 mm); or for difficult, high
temperature and harsh environments,
some model series incorporate fiber optics
for added flexibility.
The optical system, detector and electron-
ics are housed in a rugged sealed casting Series 340, 700, 800, 3R & 3L with SLR focusing Series 200, 600, 3V and 3G with SLR focusing
rated NEMA 4 (IP66) to perform in the
harsh industrial environments. Modline 3
sensors are designed to match existing
mounting configurations and offer a choice
of cooling and environmental protection
accessories.
200 Series
Measures temperatures ranging from 900
to 4800°F (500 to 2600°C) and is intended
for high temperature incandescent appli- 3G Series The series also uses Ircon’s two-color
cations. It operates in a narrow spectral Medium temperature thermometer mea- technique to measure difficult high
region from 0.7 to 1.0µm, utilizing an sures temperatures ranging from 500 to temperature applications. It is ideal for
extremely stable silicon detector. 2500°F (250 to 1400°C) and operates at processes such as molten metal, wire
1.5 to 1.6µm. It utilizes an InGaAs detector and rod, vacuum furnaces and kilns.
340 Series for exceptional stability, wider temperature
Measures temperatures ranging from 75 spans and ability to operate at higher ambi- 3V Series
to 1500°F (25 to 800°C) and is ideal for ent temperatures. This series is ideal for Gallium Arsenide thermometer measures
clear films of C-H type plastics or paints, medium temperature applications such as temperatures ranging from 400 to 1200°C
waxes and oils. It operates in a very nar- ferrous and non-ferrous metals. and operates in a narrow spectral region
row wavelength band centered at from 0.91 to 0.97µm. This series is speci-
3.43µm. 3L Series fically tailored for measuring gallium
Low temperature two-color thermometer arsenide (GaAs) wafer temperatures.
600 Series measures temperatures ranging from 500
Measures temperatures ranging from to 1800°F (250 to 1000°C) and operates at Fiber Optic Sensor Option
150 to 1400°F (80 to 800°C) and operates 1.55 and 1.68µm lower ranges and 1.10 Our fiber optic sensors are the ultimate
at 2.0 to 2.6µm. It’s ideal for general pur- and 1.68µm upper ranges. It measures in non-contact temperature measurement
pose medium temperature applications temperatures from the ratio of radiation for difficult-to-read or obstructed targets.
such as thick plastics, rubber, textiles signals of two adjacent wavelengths and The following series are available as a
and metals. not from absolute intensity. It will tolerate a fiber optic version:
more than 95% reduction in radiant intensity
700 Series Series and Temperature Range
with virtually no error. This series is most 200 200 to 4800°F (650 to 2600°C)
Measures temperatures ranging from
appropriate for low temperature non-ferrous 3G 650 to 2500°F (350 to 1400°C)
100 to 2500°F (50 to 2500°C) and oper-
metal applications including aluminum. It 3R 1300 to 6500°F (700 to 3500°C)
ates at 4.8 to 5.3µm. It is ideal for glass
features two Indium Gallium Arsenide 3V 500 to 1500°C
surface temperatures in forming, bending,
(InGaAs) detectors which measure target
tempering, annealing and sealing.
signals simultaneously delivering highly sta-
800 Series ble, highly accurate and fast measurements.
Measures temperatures ranging from
3R Series
75 to 800°F (25 to 400°C) and operates
High temperature two-color thermometer
at 7.92µm. This series measures thin film
measures temperatures ranging from 1300
of all polyester (PET) and fluorocarbon
to 6500°F (700 to 3500°C) and operates at
plastics including thin glass and ceramics.
0.7 to 1.08 µm and 1.08 µm.
3
Modline 3 Catalog
With a track and hold feature, the instrument receives a Typical Dimension Drawing shows panel mounting for
contact closure and holds the last seen temperature of the Modline 3 Indicator/Processor
billet. All functions are held (the indicator, linear outputs
and controller outputs) until the contact is opened.
4
Modline 3
Operation Features
Front Panel Displays and Controls Rear Panel Connections
“M” Button
allows you Power Supply
to scroll Connections for
through 90 to 250 Vac
menu
selections
Invalid Alarm
for 3L and 3R
series only
“F” Button
provides
control Up-Down Buttons Sensor Input Remote Reset for Peak
function. allow you to change Picker and Track /Hold
Auxiliary Analog Signal Input
Function Display indicates control values to adjust remotely Emissivity, RS-485 Digital Interface
function settings and menus in a E-Slope or Set Point-1 For digital communication
2 x 20 line character display.
SLR Sensors
• Model AA-3 Air Purge
• Models SB-1 Swivel Mounting Base
• Model WA-3 Water Cooling Accessory
• Model WJ-5 Water Cooling Jacket
Select Emissivity and Value 0.100 to 1.000
• All other Flange Mount Accessories and Sight
Tubes.
5
Modline 3 Catalog
System Specifications
Spectral Response Operating Ambient Select. Analog Outputs (cont’d)
CE Directives: Each series is designed to operate (without ambient cooling) 0 to 20 mAdc with a 1000 W max.
in a discrete wavelength band (see Series 200 and 3 G: 4 to 20 mAdc with a 1000 W max
Meets EMC Directive Model Selection Chart.) 32 to 150°F (0 to 60°C) 5 mAdc / degree F or C, (1mV/ °
89/336/EEC for EMI/RFI Series 3L and 3R: 0 to 10 Vdc
and Safety Compliance Calibration / Accuracy 32 to 130°F (0 to 55°C)
tested to: Accuracy @25°C: Series 3V: 50 to 113°F (10 to 45°C) [max 4000 mV] across 200 W
EN 50081-2: Generic 200, 3G, 3R, 3V series within Series 340, 600, 700, and 800: resistor, typical deviation two degrees
Emissions Standard 0.6% of reading (+ 1 digit) or 5°F 50 to 130°F from display)
EN 50082-2: Generic (3°C), whichever is greater. Sensor Cable Silicone Rubber:
Immunity Standard 400°F (200°C) Max. Temp. Digital Communication
EN 61010-1: Safety Standard 340, 600, 700, 800 and 3L series Indicator / Processor: RS-485 Digital Interface
within 0.6% F.S. (+ 1 digit) or 32 to 122°F (0 to 50°C)
5°F (3°C) whichever is greater. Emissivity Range*
Humidity 0.100 to 1.000.
RepeatabilitY @25°C 10 to 90% non-condensing *see pages 7 & 8 for limitations.
Within 0.1% of full-scale temperature
(+1 digit) Enclosure E Slope Range*
allows mounting two Indicator/ 0.850 to 1.150.
Response Time at Analog Output Processors side-by-side in 19 *see pages 7 & 8 for limitations.
Adjustable from 0.01 to 60 seconds inch rack; Size: 7.56 x 5.67” (192
x 144 mm) Power Requirements
90 to 250 Vac, 50/60 Hz, 40VA max.
NEMA 4 (IP66 rated) Selectable Analog Outputs
Sensor Housing and Indicator/ are isolated from ground Weight
processor enclosure Sensor: 7 to 8 lbs (3.2 to 3.6 kg)
Indicator/Processor:
9 lbs (4 kg) - approximate weight
Unique to Sensor Series 3L 3L Spectral Response Signal Reduction Range Invalid Alarm
& 3R Two-Color (Ratio) Adjacent bands: 1.50 to 1.60µ Caused by low emissivity, non- Form C relay outputs rated at
Thermometer and 1.65 to 1.71m or 1.00 to resolved or obliterated target 24 VAC/DC;@ 1 Amp.
1.20µ and 1.65 to 1.71µ. above 575°F (300°C) for 3L Resistive or Inductive.
series and above 1500°F (800°C)
3R Spectral Response for 3R Series. Will tolerate about
Adjacent bands: 0.7 to 1.08µ and 95% reduction in radiation intensity.
a narrow band centered at 1.08µ.
Peak Picker Rise Time Adjustable Decay Rate Peak Picker Reset
Same as selected Response 0.00 to 300°F (0.00 to 300°C) per Internal Reset
Time (0.01 to 60 seconds). second, depending on the instrument two Modes: Manual and Auto
model. External Resetvia contact closure.
On/Off Controller/Alarm with Response Time Remote Set Point 1 Relay Delay Time
Relay Outputs Same as selected Response Time Input Signal of 4 to 20 mA, daisy 1 to 2 milliseconds
(0.01 to 60 seconds). chain compatible.
Hysteresis
Internal Set Point Relay Outputs 2°F (2°C)
Adjustable over full temperature span Two Form C relay outputs rated at
of the instrument model. 24 V AC/DC; @ 1 Amp. Resistive
or Inductive.
PID Controller with Auto Pid Output Proportional Band (P) Manual Adjust
Tune and Deviation Alarms 4 to 20 mAdc isolated. 0.1 to 200.0% 0.0 to 100.0% of output
1000 Ohm maximum.
Reset Rate Deviation Alarm Set Points
Remote Set Point (I) - 0.01 to 99.00 repeats per minute Adjustable for HI and LO set points
Input Signal 4 to 20 mA, daisy with an Off position. over full temperature span of instru-
chain compatible. ment model, each with Off position.
Rate Time
(D) - 0.001 to 9.900 minutes, with Deviation Alarm Output
Internal Set Point Relay Outputs for HI and LO
Off position.
Adjustable over full temperature Alarms. Use two Form C relay
span of the instrument model. Load Demand outputs rated at 24 V AC/DC; @
0 to 100% of output 1Amp. Resistive or Inductive.
6
Modline 3 Catalog
600 Series SLR Version – 2.0 to 2.6µ * Limited range of response time adjustment
200 Series Fiber Optic Options** 04F15 = 150 – 400°F D/150* is 0.25 to 60 seconds.
10 ft (3 m) fiber optic cable 05F15 = 200 – 500°F D/150*
06F15 = 250 – 600°F D/150 Note: Model Selection Chart continued
25FF5 = 1200 – 2500°F D/30
on following page.
25FF8 = 1200 – 2500°F Extension Tip 08F15 = 350 – 800°F D/150
10F15 = 500 – 1000°F D/150
30FF6 = 1300 – 3000°F D/60
14F15 = 600 – 1400°F D/150
30FF7 = 1300 – 3000°F D/30 x D/150
30FF8 = 1300 – 3000°F Extension Tip
48FF6 = 1800 – 4800°F D/60
48FF7 = 1800 – 4800°F D/30 x D/150
48FF8 = 1800 – 4800°F Extension Tip
7
Modline 3 Catalog
Model Selection Chart (continued)
BLOCK B (cont.) BLOCK B (cont.)
3G Series SLR Version* – 1.5 to 1.6 µ
18F05 = 500 – 1800°F D/50 3R Series SLR Version – 0.7 to 1.08 µ and 1.08 µ BLOCK B (cont.)
20F10 = 600 – 2000°F D/100 25F05 = 1300 – 2500°F D/50 3V Series Fiber Optic Version
25F15 = 700 – 2500°F D/150 32F05 = 1800 – 3200°F D/50 10 ft (3 m) fiber optic cable
40F10 = 2000 – 4000°F D/100 15CF5 = 500 –1500°C D/30 †
10C05 = 250 – 1000°C D/50 65F15 = 2500 – 6500°F D/150 15CF8 = 500 –1500°C Extension Tip †
11C10 = 350 – 1100°C D/100
14C15 = 400 – 1400°C D/150 14C05 = 700 – 1400°C D/50 † These models are restricted to sensing head
16C05 = 900 – 1600°C D/50 ambient temperatures of 50 to 113°F (10 to
* Emissivity span is restricted to 0.3 to 1.0 for 20C10 = 1100 – 2000°C D/100 45°C) and a minimum emissivity setting of
the first 100°F (55°C) for all temperature 24C05 = 900 – 2400°C D/50 0.400.
ranges. 35C15 = 1500 – 3500°C D/150
3G Series Fiber Optic Options* 3R Series Fiber Optic Version BLOCK C Signal Conditioning
10 ft (3 m) fiber optic cable 10 ft (3 m) fiber optic cable 0 = Peak Picker and Track & Hold
22FF5 = 650 – 2200°F D/30 25FF5 = 1300 – 2500°F D/30
22FF8 = 650 – 2200°F Extension Tip 25FF8 = 1300 – 2500°F Extension Tip
25FF6 = 800 – 2500°F D/60 32FF5 = 1800 – 3200°F D/30 BLOCK D Analog Signal Output
25FF7 = 800 – 2500°F D/30 x D/150 32FF8 = 1800 – 3200°F Extension Tip 0 = 4 to 20mA, 0 to 20mA, or 5µA per
25FF8 = 800 – 2500°F Extension Tip 40FF5 = 2000 – 4000°F D/30 Degree
40FF8 = 2000 – 4000°F Extension Tip 1 = 0 to 10 Vdc
12CF5 = 350 – 1200°C D/30 65FF6 = 2500 – 6500°F D/60
12CF8 = 350 – 1200°C Extension Tip 65FF7 = 2500 – 6500°F D/30 x D/150 BLOCK E Digital Communication
14CF6 = 450 – 1400°C D/60 0 = RS 485 Digital Interface
14CF7 = 450 – 1400°C D/30 x D/150
14CF5 = 700 – 1400°C D/30
14CF8 = 450 – 1400°C Extension Tip
14CF8 = 700 – 1400°C Extension Tip
16CF5 = 900 – 1600°C D/30 BLOCK F Controller Outputs
* Emissivity span is restricted to 0.3 to 1.0
0 = None
for the first 100°F (55°C) for all temperature 16CF8 = 900 – 1600°C Extension Tip
ranges. 20CF5 =1100 – 2000°C D/30 1 = PID Controller with deviation alarms
20CF8 = 1100 – 2000°C Extension Tip and 4 to 20mA isolated output
3L Series** – 1.5 to 1.6 µ and 1.65 to 1.71µ 24CF6 = 900 – 2400°C D/60 2 = 2-Point On/Off Controller with relay
10F05 = 500 – 1000F D/50 24CF7 = 900 – 2400°C D/30 x D/150 outputs
14F10 = 700 – 1400F D/100 35CF6 = 1500 – 3500°C D/60
18F10 = 1000 – 1800F D/100* 35CF7 = 1500 – 3500°C D/30 x D/150
3V Series SLR Version * – 0.91 to 0.97 µ
05C05 = 250 – 550°C D/50
10C02 = 400 –1000°C D/20
07C10 = 400 – 750°C D/100
10C10 = 550 – 1000°C D/100* 12C05 = 450 –1200°C D/50
IRCON, Inc.
Worldwide Headquarters
Santa Cruz, CA USA
Tel: 1 800 227 8074 (USA and Canada, only)
1 831 458 3900 www.ircon.com
info@ircon.com
European Headquarters
Berlin, Germany United Kingdom
Tel: 49 30 4 78 00 80 Tel: +44 1908 630 800
China Headquarters
Beijing, China
Tel: 8610 6438 4691
Worldwide Service
IRCON offers services, including repair and calibration.
For more information, contact your local office or e-mail info@ircon.com © 2009 IRCON, Inc. (3309357 Rev J ) 9/2009
The IRCON logo is a registered trademark of IRCON, Inc.
Specifications subject to change without notice.