HY series Economical digital temperature controller
Specification Model HY-8000S HY-8200S HY-72D HY-48D
Appearance
W×H×D(mm) 96 X 96 X 125 96 X 96 X 125 72 X 72 X 110 48 X 48 X 100
Power Voltage 110 / 220 V a.c. (50 / 60 Hz) Power Consumption 3 VA Input(Sensor type) selection by the configuration suffix code. Input a) Thermo couple : K, J, R b) RTD : KPt100 Ω(KS), Pt100 Ω(IEC 751) c)DC current : 4 to 20 mA d) DC voltage : 1 to 5 V d.c. Relay contact : 250 V a.c. 3 A (Resistive load), SSR: 12 V d.c. (Constant voltage pulse) [Load resistance min. 800 Ω], Control Output Current: 4 - 20 mA d.c. [Load resistance max. 600 Ω) Control action Proportional or ON/OFF control Alarm Output - Relay contact : 250 V a.c. 3 A - Setting Method By B.C.D S/W Indication range Setting temperature range Display LED Display Setting and display accuracy Set Value : ±1.0 % of FS, Display :±0.5 % of FS Control sensitivity Approx 0.2 % FS (Fixed) Proportional Cycle Relay contact:25 ~ 30 sec SSR:2 ~ 4 sec Reset Range Max. ±1.5 % of Range Dielectric Strength 2,000 V a.c. 50/60 ㎐ for 1 minute (Primary terminal-secondary terminal) Malfunction Resistance 2 - 55 ㎐, X·Y·Z each position for 10 minutes Vibration Mechanical Durability 10 - 55 ㎐, 0.76 ㎜, X·Y·Z each positions for 2 hours Malfunction Resistance 100 ㎨ 6 positions, each 3 times Shock Mechanical Durability 300 ㎨ 6 positions, each 3 times Mechanical Min.10 million times (Relay type) Life Electrical Min. 0.3 million times (Relay type) Ambient temperature and humidity 0 ~ 50 ℃ (32 ~122 ℉) 35 ~ 85 % RH (Without freeze)
Suffix Code Range and input code chart
Model Code Information HY-8000S, 8200S HY-72D HY-48D HY- - Digital temperature controller Classification Code Input Input Input Range (℃) Range (℃) Range (℃) 8000S 96 X 96 ㎜ type type type 96 X 96 4 - - - - 0 ~ 299 8200S K, J Dimension (alarm setting general specification) 5 - - - - 0 ~ 399 72D 72 X 72 6 0 ~ 199 0 ~ 199 48D 48 X 48 7 0 ~ 299 0 ~ 299 K,J F ON/OFF control 8 K, J 0 ~ 399 0 ~ 399 Control type P Proportional control 9 - 0 ~ 599 Thermocouple K K thermocouple 10 0 ~ 599 0 ~ 799 - - J J thermocouple 11 0 ~ 799 K - R R thermocouple 12 - 0 ~ 1199 K Input D RTD KPt 100 Ω 600 ~ 13 0 ~ 1199 R P RTD Pt 100 Ω (IEC) 1699 14 R 600 ~ 1699 - - V 1 - 5 V d.c. 1 - - - - -49 ~ 49 C 4 - 20 ㎃ d.c. 2 -99 ~ 99 -99 ~ 99 -99 ~ 99 M Relay Pt100 3 -99 ~ 199 -99 ~ 199 0 ~ 199 Control output C Current output (4 - 20 ㎃ d.c.) Ω 4 0 ~ 99 0 ~ 99 0 ~ 299 S SSR (voltage pulse output, 12 V d.c.) RTD Pt100 Pt100 5 - - 0 ~ 399 N None Ω Ω Alarm output 6 0 ~ 199 0 ~ 199 O High alarm (HY-8200S) 7 0 ~ 299 0 ~ 299 - - R Reverse action (heating control) Control action(Internal selection) 8 0 ~ 399 0 ~ 399 D Direct action (cooling control) 1-5 1-5 Voltage/ - 0 ~ 99 0 ~ 99 1-5V 0 ~ 99 Range code Refer to the range and input code V V current 4 - 20 4 - 20 4 - 20 (DC) - 0 ~ 99 0 ~ 99 0 ~ 99 mA mA mA