Sei sulla pagina 1di 120

Limit States

Design Guide
for Canada

Supplement to the
Hilti North American
Product Technical Guide

2013 Edition
Mechanical Anchoring Systems

Are your anchors code compliant?


Anchoring Solutions for CSA A23.3-04 Annex D
The CSA A23.3-04 Annex D code specifies design requirements for anchors in concrete
used to transmit forces to concrete elements by tension, shear, or a combination of ten-
sion and shear. The Annex applies to both cast-in anchors and post-installed mechani-
cal anchors according to Limit States Design.
Hilti, as one of the leading fastening authorities in the world, has set industry standards
in performance for mechanical and adhesive anchor systems for decades.
To address the requirements of CSA A23.3-04 Annex D and beyond, Hilti is the first
manufacturer to offer mechanical anchor solutions verifying compliance with the latest
code. In addition to the KB-TZ stud-type medium duty expansion anchor, Hilti offers
two other proven and listed alternatives which are suitable for anchoring applications in
accordance with the CSA A23.3-04 Annex D, the HSL-3 heavy-duty expansion anchor
and the HDA self-undercutting anchor.

For more information visit www.hilti.ca/anchors or email hnatechnicalservices@hilti.com

Hilti has it! – Proven and Approved Anchoring Solutions for CSA A23.3-04 Annex D

Reliable in virtually Outperformance.


all conditions. HDA undercut anchor
KB-TZ expansion anchor Ideal for heavy duty and safety fastenings in
This stud-type medium-duty anchor is the right VÀ>VŽi`ÊVœ˜VÀiÌiÊ­Ìi˜Ãˆœ˜Ê✘i®Ê܈̅Ê̅iÊ>LˆˆÌÞÊ
choice for a wide range of applications. to handle high loads combined with close edge
UÊ -ՈÌ>LiÊvœÀÊVœ˜VÀiÌiʜÛiÀʓiÌ>Ê`iVŽ distances and spacing.
applications UÊ *iÀvœÀ“>˜ViÊVœ“«>À>LiÊ̜ÊV>Ã̇ˆ˜‡«>Vi
UÊ -“>Ê“ˆ˜ˆ“Õ“Êi`}iÊ`ˆÃÌ>˜ViÊ>˜` headed stud
spacing for design flexibility UÊ >ÃÌÊ>˜`Êi>ÃÞʈ˜ÃÌ>>̈œ˜pÃiv‡Õ˜`iÀVÕÌ̈˜}
UÊ ˜V…œÀÊÈâiʈÃÊÃ>“iÊ>ÃÊ`ÀˆÊLˆÌÊÈâi anchor installs in minutes
UÊ ,>ˆÃi`Ê­`œ}Ê«œˆ˜Ì®Êˆ“«>VÌÊÃiV̈œ˜Ê̜ UÊ ՏÞÊÀi“œÛ>LiÊ>vÌiÀʈ˜ÃÌ>>̈œ˜
prevent thread damage during installation
UÊ *Àœ`ÕVÌÊ>˜`ʏi˜}̅ʈ`i˜ÌˆwV>̈œ˜ÊVœ`iÃ
to facilitate quality control and inspection
after installation

Best in class.
HSL-3 expansion anchor
This heavy-duty expansion anchor offers high
reliability and superior installation safety.
UÊ ˆ}…ʏœ>`ÊV>«>VˆÌÞ
UÊ Û>ˆ>Liʈ˜ÊÎʅi>`ÊVœ˜w}ÕÀ>̈œ˜Ã\ʅiÝʅi>`]
torque cap or stud
UÊ ,iˆ>LiÊV>“«ˆ˜}ʜvÊ«>ÀÌÊv>ÃÌi˜i`Ê̜
overcome gaps
UÊ i˜iÀ>ÞÊÃՈÌ>LiÊvœÀÊ`ޘ>“ˆVʏœ>`ˆ˜}ÊÊ Ê
Ê ˆ˜VÕ`ˆ˜}ÊÃiˆÃ“ˆV]Êv>̈}ÕiÊ>˜`ÊŜVŽ

Hilti. Outperform. Outlast.


Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Table of Contents

HDA Undercut Anchor 1.0 2

*Àœ`ÕVÌÊ iÃVÀˆ«Ìˆœ˜ÊÊÊʇÊÊÊ2
Material Specifications - 2
Technical Data - 3
HDA Design Information for CSA A23 Annex D - 4
Sample Calculation - 6
Notes for Design Tables - 8
>V̜Ài`Ê,iÈÃÌ>˜ViÊ/>LiÃʇÊ/i˜Ãˆœ˜ÊÊʇÊÊÊ9
>V̜Ài`Ê,iÈÃÌ>˜ViÊ/>LiÃʇÊ-…i>ÀÊÊʇÊÊÊ£3
Installation Instructions - 23
Ordering Information - 25

HSL-3 Heavy Duty Sleeve Anchor 2.0 27

*Àœ`ÕVÌÊ iÃVÀˆ«Ìˆœ˜ÊÊʇÊÊÊÓ7
Material Specifications - 27
Technical Data - 28
HSL-3 Design Information for CSA A23.3 Annex D - 29
Sample Calculation - 30
Notes for Design Tables - 31
>V̜Ài`Ê,iÈÃÌ>˜ViÊ/>LiÃʇÊ/i˜Ãˆœ˜ÊÊʇÊÊÊÎ2
>V̜Ài`Ê,iÈÃÌ>˜ViÊ/>LiÃʇÊ-…i>ÀÊÊʇÊÊÊÎ6
Installation Instructions - 49
Ordering Information - 49

Kwik Bolt TZ Expansion Anchor 3.0 50

*Àœ`ÕVÌÊ iÃVÀˆ«Ìˆœ˜ÊÊʇÊÊÊx0
Material Specifications - 51
Technical Data - 52
KB-TZ Design Information for CSA A23.3 Annex D - 53
 ‡,/<Ê iÈ}˜Ê˜vœÀ“>̈œ˜ÊvœÀÊ
-ÊÓΰÎʘ˜iÝÊ ÊÊʇÊÊÊx4
Notes for Design Tables (Carbon Steel KB-TZ) - 57
>V̜Ài`Ê,iÈÃÌ>˜ViÊ/>LiÃʇÊ/i˜Ãˆœ˜Ê­
>ÀLœ˜Ê-Ìii®ÊÊʇÊÊÊx8
>V̜Ài`Ê,iÈÃÌ>˜ViÊ/>LiÃʇÊ-…i>ÀÊ­
>ÀLœ˜Ê-Ìii®ÊÊʇÊÊÊÈ5
œÌiÃÊvœÀÊ iÈ}˜Ê/>LiÃÊ­-Ì>ˆ˜iÃÃÊ-ÌiiÊ ‡,/<®ÊÊʇÊÊÊn8
>V̜Ài`Ê,iÈÃÌ>˜ViÊ/>LiÃʇÊ/i˜Ãˆœ˜Ê­-Ì>ˆ˜iÃÃÊ-Ìii®ÊÊʇÊÊÊn9
>V̜Ài`Ê,iÈÃÌ>˜ViÊ/>LiÃʇÊ-…i>ÀÊ­-Ì>ˆ˜iÃÃÊ-Ìii®ÊÊʇÊÊʙ3
Installation Instructions - 115
Ordering Information - 116

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 1
Mechanical Anchoring Systems

1.0 HDA Undercut Anchor


£°£Ê *Àœ`ÕVÌÊ iÃVÀˆ«Ìˆœ˜ 1.1 Product Description
1.2 Material Specifications The Hilti HDA Undercut Anchor is a UÊ 1˜`iÀVÕÌʎiވ˜}ʏœ>`ÊÌÀ>˜ÃviÀÊ
1.3 Technical Data heavy duty mechanical undercut anchor allows for reduced edge distances
whose undercut segments incorporate and anchor spacings
1.4 Installation Instructions
carbide tips so as to perform a self- UÊ /…ÀœÕ}…‡ÃiÌÊÃÌޏiÊ«ÀœÛˆ`iÃÊ
1.5 Ordering Information increased shear capacity
undercutting process designed to
£°ÈÊ  Ê,i“œÛ>Ê/œœ develop a ductile steel failure. The HDA UÊ ՏÞÊÀi“œÛ>Li
ÃÞÃÌi“ʈ˜VÕ`iÃÊiˆÌ…iÀÊ«ÀiÃiÌÊ­ ‡*®Ê UÊ -…iÀ>À`ˆâi`Ê­xÎÊM“Ê∘V®Ê>˜`ÊÊ Ê
316 stainless steel for corrosive
or through-set (HDA-T) style anchors,
environments
stop drill bits, setting tool, and roto-
UÊ -…iÀ>À`ˆâi`Ê∘VÊVœ>̈˜}ʅ>ÃÊ
…>““iÀÊ`ÀˆÊvœÀÊvœÕÀʓiÌÀˆVÊLœÌÊÈâiÃ\Ê
equivalent corrosion resistance to
M10, M12, M16 and M20. The HDA …œÌÊ`ˆ««i`Ê}>Û>˜ˆâˆ˜}Ê
ˆÃÊ>Û>ˆ>Liʈ˜Ê>ÊÅiÀ>À`ˆâi`Ê>˜`ÊΣÈÊ
stainless steel versions for outdoor Guide Specifications
i˜ÛˆÀœ˜“i˜ÌÃ°Ê >V…ÊÈâiÉÃÌޏiʈÃʜvviÀi`Ê Undercut Anchors. Undercut anchors
in two lengths to accommodate various Å>ÊLiʜvÊ>˜Ê՘`iÀVÕÌÊÃÌޏiÊ܈̅ÊLÀ>âi`Ê
“>ÌiÀˆ>Ê̅ˆVŽ˜iÃÃiÃÊ̜ÊLiÊv>ÃÌi˜i`Ê tungsten carbides on the embedded
(except M10). end that perform the self-undercutting
Product Features process. Undercut portion of anchor
shall have a minimum projected bearing
UÊ 1˜`iÀVÕÌÊÃi}“i˜ÌÃÊ«ÀœÛˆ`iÊV>Ã̇
area equal to or greater than 2.5 times
ˆ˜‡«>ViʏˆŽiÊ«iÀvœÀ“>˜ViÊ܈̅ÊÊÊ
limited expansion stresses the nominal bolt area. The bolt shall
conform to ISO 898 class 8.8 strength
UÊ -iv‡Õ˜`iÀVÕÌ̈˜}ÊÜi`}iÃÊ«ÀœÛˆ`iÊ
an easy, fast and reliable anchor requirements. Anchors dimensioned
installation and supplied by Hilti.
UÊ ÝVii˜ÌÊ«iÀvœÀ“>˜Viʈ˜ÊVÀ>VŽi`Ê Installation ,iviÀÊ̜ʣ°{
Vœ˜VÀiÌiÊ­Ìi˜Ãˆœ˜Ê✘iÃ]Êi>À̅-
µÕ>Ži‡ÀiÈÃ̈˜}ÊÃÌÀÕVÌÕÀiî

Mechanical Properties
1.2 Material Specifications fy min. fu
MPa MPa
HDA-P HDA-T HDA-T/-TF/-P/-PF carbon steel cone bolt; M10, M12, M16 and M20
Heavy-Duty Heavy-Duty
Undercut Anchor Undercut Anchor meets strength requirements of ISO 898, class 8.8 640 800
(Pre-Set Type) (Through-Set Type)
HDA-T/-TF/-P/-PF carbon steel sleeve; M10 & M12
conforms to European Standard No. 25CrMoS4 – 850
HDA-T/-TF/-P/-PF carbon steel sleeve; M16
conforms to European Standard No. 25CrMoS4 – 700
HDA-T/-TF/-P/-PF carbon steel sleeve; M20
conforms to European Standard No. 25CrMoS4 – 550
HDA-TR/-PR stainless steel cone bolt; M10, M12 and M16
conforms to AISI 316 or 316 Ti 600 800
HDA-TR/-PR stainless steel sleeve; M10 and M12
conforms to AISI 316 or 316 Ti – 850
Components
HDA-TR/-PR stainless steel sleeve; M16 conforms to AISI 316 or 316 Ti – 700
UÊ-̜«Ê ÀˆÊ ˆÌ HDA-T/-TF/-P/-PF nut conforms to DIN 934, grade 8
HDA-TR/-PR nut conforms to DIN 934, grade A4-80
UÊ-iÌ̈˜}Ê/œœ
HDA-T/-TF/-TR/-P/-PF/-PR washer conforms to DIN 6796
UÊ,œÌ>ÀÞ HDA-T/-P components are electroplated min. 5 μm zinc
Hammer Drill HDA-TF/-PF sherardized components have average 53 μm zinc

2 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HDA Undercut Anchor 1.0

1.3 Technical Data


Anchor Nomenclature

Hilti Design Anchor


P-pre-set before baseplate
T-through-set after/through
do

t fix
do baseplate
dh
t fix

dh
Blank-carbon steel zinc plated
F-carbon steel sherardized
R-R-316 stainless steel
Drill bit diameter (mm)
h ef

h ef
ho

ho
Metric
h

h
Thread diameter (mm)
HDA-PF 22 M 12 x 125 / 50
Minimum embedment of undercut
Maximum fastening thickness
HDA-T d bit HDA-P d bit
Table 1 - HDA Specifications
Anchor Size HDA-T/HDA-P M10 x 100/20 M12 x 125/30 M12 x 125/50 M16 x 190/40 M16 x 190/60 M20 x 250/50 M20 x 250/100
h Thickness of base
material, min.1 mm (in.) 170 (6-3/4) 190 (7-1/2) 190 (7-1/2) 270 (10-5/8) 270 (10-5/8) 350 (13-3/4) 350 (13-3/4)
 Total anchor length mm (in.) 150 (5.90) 190 (7.48) 210 (8.27) 275 (10.83) 295 (11.61) 360 (14.17) 410 (16.14)
length I.D. code2 letter I L N R S V W
tfix Fastening thickness
HDA-T, min.3 mm (in.) 10 (0.39) 10 (0.39) 10 (0.39) 15 (0.59) 15 (0.59) 20 (0.79) 20 (0.79)
HDA-T, max. mm (in.) 20 (0.79) 30 (1.18) 50 (1.97) 40 (1.58) 60 (2.36) 50 (1.97) 100 (3.94)
HDA-P, max. mm (in.) 20 (0.79) 30 (1.18) 50 (1.97) 40 (1.58) 60 (2.36) 50 (1.97) 100 (3.94)
d bit Nom. dia. of drill bit4 mm 20 22 22 30 30 37 37
ho Min. depth of drill hole mm (in.) 107 (4.21) 134.5 (5.30) 134.5 (5.30) 203 (7.99) 203 (7.99) 266 (10.47) 266 (10.47)
h ef Effective anchoring depth mm (in.) 100 (3.94) 125 (4.92) 125 (4.92) 190 (7.48) 190 (7.48) 250 (9.84) 250 (9.847)
dh Recommended clearance
hole (min.) HDA-T mm (in.) 21 (7/8) 23 (15/16) 23 (15/16) 32 (1-1/4) 32 (1-1/4) 40 (1-9/16) 40 (1-9/16)
HDA-P mm (in.) 12 (1/2) 14 (9/16) 14 (9/16) 18 (3/4) 18 (3/4) 22 (7/8) 22 (7/8)
do Anchor Diameter, HDA-T mm (in.) 19 (0.748) 21 (0.827) 21 (0.827) 29 (1.142) 29 (1.142) 36 (1.42) 36 (1.42)
HDA-P mm (in.) 10 (0.394) 12 (0.472) 12 (0.472) 16 (0.630) 16 (0.630) 20 (0.78) 20 (0.78)
dw Washer diameter mm (in.) 27.5 (1.08) 33.5 (1.32) 33.5 (1.32) 45.5 (1.79) 45.5 (1.79) 50 (1.97) 50 (1.97)
Sw Width across flats mm (in.) 17 19 19 24 24 30 30
Tmax. Max. tightening torque5 Nm (ft-lb) 50 (37) 80 (59) 80 (59) 120 (88) 120 (88) 300 (221) 300 (221)
Sleeve properties
A sl Cross sectional area mm2 (in2) 196 (0.304) 223 (0.346) 223 (0.346) 445 (0.690) 445 (0.690) 675.6 (1.047) 675.6 (1.047)
S sl Elastic section modulus mm3 (in3) 596 (0.0364) 779 (0.0475) 779 (0.0475) 2110 (0.1288) 2110 (0.1288) 3950 (0.241) 3950 (0.241)
Bolt properties
Ab Bolt nominal area mm2 (in2) 78.5 (0.122) 113 (0.175) 113 (0.175) 201 (0.312) 201 (0.312) 314.16 (0.487) 314.16 (0.487)
At Bolt tension area mm2 (in2) 58 (0.090) 84.3 (0.131) 84.3 (0.131) 157 (0.243) 157 (0.243) 245 (0.380) 245 (0.380)
Sb Elastic section modulus mm3 (in3) 67 (0.0041) 117 (0.0071) 117 (0.0071) 293 (0.0179) 293 (0.0179) 541.3 (0.033) 541.3 (0.033)
A brg Undercut bearing area6 mm2 (in2) 260 (0.403) 354 (0.549) 354 (0.549) 624 (0.967) 624 (0.967) 707.1 (1.096) 707.1 (1.096)
1 Base material thickness as required to minimize split- 3 Minimum thickness of fastened part as required to 5 Torque tightening of the anchor is not required for
ting as per CSA A23.3-04 Annex D. ensure engagement of full sleeve cross section in proper set. Torque tightening may reduce initial slip
2 Length code in accordance with ICC-ES Acceptance shear. under load and can improve fatigue performance.
Criteria AC193. 4 Metric stop drill bit must be used. See Section 1.4 for 6 Recommended area for calculating maximum bearing
use of matched tolerance diamond core bits. stress in accordance with the CSA A23.3-04 Annex D.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 3
Mechanical Anchoring Systems

1.0 HDA Undercut Anchor


Table 2 — HDA Design Information for use with CSA A23.3-04, Annex D
Nominal Anchor Diameter Ref.
Design Parameter Symbol Units
M10 M12 M16 M20 A23,3-04
HDA HDA-R HDA HDA-R HDA HDA-R HDA
Anchor O.D. do mm 19 21 29 35
Effective min. embedment depth hef,min mm 100 125 190 250
Minimum edge distance cmin mm 80 100 150 200
Minimum anchor spacing smin mm 100 125 190 250
ˆ˜ˆ“Õ“Ê“i“LiÀÊ̅ˆVŽ˜iÃÃÊ hmin mm 180 200 270 350
Anchor category 1,2 or 3 1 1 1 1 D.5.4c
Concrete material resistance
Fc 0.65 0.65 0.65 0.65 8.4.2
factor for concrete
Steel embedment material
Fs 0.85 0.85 0.85 0.85 8.4.3
resistance factor for reinforcement
Strength reduction factor for
,Ê Ê Ê ä°näÊ Ê Ê ä°näÊ Ê Ê ä°näÊ Ê ä°näÊ °x°{>
tension, steel failure modes
Strength reduction factor for
,Ê Ê Ê ä°ÇxÊ Ê Ê ä°ÇxÊ Ê Ê ä°ÇxÊ Ê ä°ÇxÊ °x°{°>
shear, steel failure modes
-ÌÀi˜}̅ÊÀi`ÕV̈œ˜Êv>V̜ÀÊvœÀÊ ,Ê
œ˜`°ÊÊ Ê £°£xÊ Ê Ê £°£xÊ Ê Ê £°£xÊ Ê £°£xÊ °x°{°V
Ìi˜Ãˆœ˜]ÊVœ˜VÀiÌiÊv>ˆÕÀiʓœ`iÃÊ ,Ê
œ˜`°Ê Ê Ê £°ääÊ Ê Ê £°ääÊ Ê Ê £°ääÊ Ê £°ääÊ °x°{V
-ÌÀi˜}̅ÊÀi`ÕV̈œ˜Êv>V̜ÀÊvœÀÊ ,Ê
œ˜`°ÊÊ Ê £°£xÊ Ê Ê £°£xÊ Ê Ê £°£xÊ Ê £°£xÊ °x°{°V
Åi>À]ÊVœ˜VÀiÌiÊv>ˆÕÀiʓœ`iÃÊ ,Ê
œ˜`°Ê Ê Ê £°ääÊ Ê Ê £°ääÊ Ê Ê £°ääÊ Ê £°ääÊ °x°{V
Yield strength of anchor steel fyÊ *>Ê È{äÊ Ê ÈääÊ È{äÊ Ê ÈääÊ È{äÊ Ê ÈääÊ È{ä
Ultimate strength of anchor steel futÊ *>Ê Ê nääÊ Ê Ê nääÊ Ê Ê nääÊ Ê nää
Effective cross-sectional area
A se mm2 58.1 84.5 156.8 245.2 D.6.1.2
of anchor
>V̜Ài`ÊÃÌiiÊÀiÈÃÌ>˜ViÊ
NsrÊ Ž Ê Ê Î£°ÈÊ Ê Ê {È°äÊ Ê Ê nx°ÎÊ Ê £Îΰ{Ê °È°£°Ó
in tension
Coefficient for factored concrete
k 10 10 10 10 D.6.2.6
LÀi>ŽœÕÌÊÀiÈÃÌ>˜Viʈ˜ÊÌi˜Ãˆœ˜
Modification factor for
resistance in tension to account #c,N 1.25 1.25 1.25 1.25 D.6.2.6
vœÀÊ՘VÀ>VŽi`ÊVœ˜VÀiÌi
>V̜Ài`ʫՏœÕÌÊÀiÈÃÌ>˜Viʈ˜Ê
Npr,crÊ Ž Ê ÓÇ°™Ê Ê ÓÇ°™Ê Î{°™Ê Ê Î{°™Ê ș°nÊ Ê È™°nÊ £ä{°ÇÊ °È°Î°Ó
ÓäÊ*>ÊVÀ>VŽi`ÊVœ˜VÀiÌi
>V̜Ài`ÊÃÌiiÊÀiÈÃÌ>˜Viʈ˜Ê
VsrÊ Ž Ê £{°ÓÊ Ê £Ç°ÓÊ Óä°ÇÊ Ê Óx°xÊ În°{Ê Ê {Ç°nÊ xn°™Ê °Ç°£°ÓV
Åi>ÀÊ ‡*É*,]ÊÃÌ>̈V
>V̜Ài`ÊÃÌiiÊÀiÈÃÌ>˜Viʈ˜Ê
Vsr,seismicÊ Ž Ê £Ó°ÇÊ Ê £x°™Ê £n°xÊ Ê ÓÓ°™Ê Î{°{Ê Ê {Ó°ÇÊ xÓ°™
Åi>ÀÊ ‡*É*,]ÊÃiˆÃ“ˆV

4 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HDA Undercut Anchor 1.0


Table 3 - Steel Strength in Shear, HDA-T (kN)

Thickness of Steel Strength Steel Strength


Anchor Designation fastened part(s) in Shear, in Shear,
Static (kN)b Seismic1 (kN)a,b
Carbon Steel Anchors mm Vsr Vsr,seismic
10 ≤ t < 15 39.5 35.7
HDA-T 20-M10x100
15 ≤ t < 20 44.6 40.2
10 ≤ t < 15 47.2 42.7
HDA-T 22-M12x125
15 ≤ t ≤ 50 52.9 47.2
15 ≤ t < 20 86.7 77.8
20 ≤ t < 25 98.2 88.6
HDA-T 30-M16x190
25 ≤ t < 30 108.4 97.5
30 ≤ t ≤ 60 117.3 105.2
20 ≤ t < 35 128.1 115.4
HDA-T 37-M20x250 35 ≤ t < 50 144.1 129.4
50 ≤ t ≤ 100 154.9 139.6

Stainless Steel Anchors mm Vsr Vsr,seismic


10 ≤ t < 15 44.0 39.5
 ‡/,ÊÓ䇣äÝ£ää
15 ≤ t < 20 45.9 41.4
10 ≤ t < 15 57.4 51.0
 ‡/,ÊÓӇ£ÓÝ£ÓxÊ
15 ≤ t ≤ 50 63.1 56.7
15 ≤ t < 20 101.4 91.2
20 ≤ t < 25 107.1 96.3
 ‡/,ÊÎ䇣ÈÝ£™ä
25 ≤ t < 30 112.2 100.7
30 ≤ t ≤ 60 116.0 104.6
a The nominal steel strength Vsr,seismicÊvœÀÊ̅iÊ ‡*ÊÅ>ÊLiÊÌ>Ži˜ÊvÀœ“Ê̅iÊ Ê iÈ}˜Ê˜vœÀ“>̈œ˜Ê/>Li
LÊ œÀÊ}ÀœÕ«ÃʜvÊ>˜V…œÀÃ]ʓՏ̈«ÞÊÛ>ÕiÊLÞʘՓLiÀʜvÊ>˜V…œÀÃ]ʘ

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 5
Mechanical Anchoring Systems

1.0 HDA Undercut Anchor

HDA-T Undercut Anchor Sample Calculations

Given: AN
2 HDA-T M10 anchors under static tension and 1.5h ef
shear loads as shown.
N f = 25 k N
Vf ÊrÊ£Îʎ
h = 300 mm

h ef
s = 300 mm

h
Slab on grade, f'cÊrÊÓäÊ*>°
ÃÃՓiÊVÀ>VŽi`ÊVœ˜VÀiÌi°
Condition B per CSA A23.3 D.5.4 c)
Calculate the factored tensile and shear resistance 1.5h ef
1.5h ef c = 200 mm
for this configuration.
A -A

Tension Resistance Calculations per CSA A23.3-04 Annex D. Code Ref.


Step 1. Calculate factored steel resistance of anchor in tension
N sr = nA se F s f u t ,ÊrÊÓÊÝÊxn°£ÊÝÊä°nxÊÝÊnääÊÝÊä°nÊrÊÈΰÓʎ Ê °È°£°Ó
­ÌiÀ˜>̈Ûi\ÊÊ,iviÀÊ̜Ê>V̜Ài`Êœ>`Ê/>LiÃʈ˜Ê̅ˆÃÊ-Õ««i“i˜Ì®
-Ìi«ÊΰÊ6iÀˆvÞʓˆ˜ˆ“Õ“ÊVœ˜VÀiÌiÊ̅ˆVŽ˜iÃÃ]ʓˆ˜ˆ“Õ“Êë>Vˆ˜}Ê>˜`Êi`}iÊ`ˆÃÌ>˜Vi\
hminÊrÊ£näʓ“ʐÊÎääʓ“ÆʜŽÊ
D.9
sminÊrÊ£ääʓ“ʐÊÎääʓ“ÆʜŽ
cminÊrÊnäʓ“ʐÊÓääʓ“ÆʜŽ
-Ìi«ÊΰÊ
>VՏ>ÌiÊv>V̜Ài`ÊVœ˜VÀiÌiÊLÀi>ŽœÕÌÊÃÌÀi˜}̅ʜvÊ>˜V…œÀʈ˜ÊÌi˜Ãˆœ˜ÊÊ
D.6.2.1
N cbgr = (ANÉANo) #ec,N #ed,N #c,N #cp,N Nbr
Step 3a. Calculate ANo and ANÊvœÀÊ̅iÊ>˜V…œÀ>}i\Ê
ANO = 9 h e f 2 = 9 x (100)2 = 90,000 mm2 D.6.2.1
AN = (1.5h e f + s + 1.5h ef )(1.5 h ef + 1.5h ef ®ÊrÊQ£°xÊÝÊ­£ää®Ê³ÊÎääʳʣ°xÊÝÊ­£ää®RÊQ£°xÊÝÊ­£ää®Ê³Ê£°xÊÝÊ­£ää®RÊrÊ ˆ}°Ê °È
180,000 mm2 ≤ 2ANO ÆʜŽ
Step 3b. Calculate N br \Ê
D.6.2.2
N b r = k F c (f' c ) 0. 5 h e f 1. 5 R = 10 x 0.65 x 200.5 x 1001.5ÊÝÊ£°ääÊrÊә°äÇʎ
Step 3c. Calculate modification factor for eccentrically loaded anchors groups #ec,N = 1; no eccentricity D.6.2.4
-Ìi«ÊÎ`°Ê
>VՏ>Ìiʓœ`ˆwV>̈œ˜Êv>V̜ÀÊvœÀÊi`}iÊivviVÌÃ\Ê#ed,N = 1.0 (c m i n > 1.5h e f ) D.6.2.5
Step 3e. #c,NÊrÊ£°äÊ­VÀ>VŽi`ÊVœ˜VÀiÌi®Ê °È°Ó°È
-Ìi«ÊÎv°Ê
>VՏ>Ìiʓœ`ˆwV>̈œ˜Êv>V̜ÀÊvœÀÊ돈Ì̈˜}\ÊÊ
D.6.2.7
#cp,N = 1.0 (splitling does not govern)
Step 3g. Calculate N cbg r\ÊÊN cbg r ÊrÊ­£nääääÊÉʙääää®ÊÝÊ£ÊÝÊ£ÊÝÊ£ÊÝÊ£ÊÝÊә°äÇÊrÊxn°£{ʎ Ê
D.6.2.1
­ÌiÀ˜>̈Ûi\ÊÊ,iviÀÊ̜Ê>V̜Ài`Êœ>`Ê/>LiÃʈ˜Ê̅ˆÃÊ-Õ««i“i˜Ì®
-Ìi«Ê{°Ê
…iVŽÊv>V̜Ài`ʫՏœÕÌÊÀiÈÃÌ>˜Vi\Ê°Ê
D.6.3.1
Ncpr = n#cp,N NprÊrÊÓÊÝÊ£°äÊÝÊÓÇ°™ÊrÊxx°nʎ Ê­ÃiiÊ Ê iÈ}˜Ê˜vœÀ“>̈œ˜Ê/>LiÊvœÀÊNpr)
-Ìi«Êx°Ê
œ˜ÌÀœˆ˜}Êv>V̜Ài`ÊÌi˜ÃˆiÊÀiÈÃÌ>˜Vi\ÊN r = N c p r ÊrÊxx°nʎ ʀÊNf

6 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HDA Undercut Anchor 1.0


Shear Resistance Calculations per CSA A23.3-04 Annex D. Code Ref.
Step 1. Calculate factored steel resistance of anchor in shear
VsrÊrÊÓ ÊÝÊÎ ™°x ÊrÊǙ° äÊ Ž Ê ­> à à Փi Ê £ÓÊ ““Ê « > Ìi Ê Ì … ˆ V Ž ˜ i à à ® Ê °Ç°£°Ó
­ÌiÀ˜>̈Ûi\ÊÊ,iviÀÊ̜Ê>V̜Ài`Êœ>`Ê/>LiÃʈ˜Ê̅ˆÃÊ-Õ««i“i˜Ì®
-Ìi«ÊÓ°Ê
>VՏ>ÌiÊv>V̜Ài`ÊVœ˜VÀiÌiÊLÀi>ŽœÕÌÊÃÌÀi˜}̅ʜvÊ>˜V…œÀʈ˜ÊÅi>ÀÊÊ
D.7.2.1
Vcbgr = (AVÉAVo) #ec,V #ed,V #c,V #h,V Vbr
Step 2a. Calculate AVo and AVÊvœÀÊ̅iÊ>˜V…œÀ>}i\ÊÊ
D.7.2.1
AVo = 4 . 5c 1 2 = 4.5 x (200)2 = 180,000 mm2
ˆ}°Ê °£ä
AV = (h)(1.5c1 + 300 + 1.5c1) = (300)[(1.5 x (200) + 300 + 1.5 x (200)] = 270,000 mm2 ≤ 2 AVoÆʜŽ
Step 2b. Calculate Vbr\ÊÊÊ
D.7.2.3
Vbr = 0.58(l/do)0.2(do)0.5F c(f’c)0.5c11.5R = ä°xnÊÝÊ­£ääÉ£™®0.2 x 190.5 x 0.65 x 200.5 x 2001.5ÊÝÊ£°ääÊrÊÓn°™nʎ
Step 2c. Calculate modification factor for eccentrically loaded anchors groups
D.7.2.5
#ec,V' = 1; no eccentricity
-Ìi«ÊÓ`°Ê
>VՏ>Ìiʓœ`ˆwV>̈œ˜Êv>V̜ÀÊvœÀÊi`}iÊivviVÌÃ\ÊÊ
D.7.2.6
#ed,V = 1.0 (c 2 > 1.5 c 1 )
Step 2e. #c,VÊrÊ£°äÊ­VÀ>VŽi`ÊVœ˜VÀiÌiÊ܈̅ʘœÊi`}iÊÀiˆ˜vœÀVi“i˜Ì®Ê °Ç°Ó°Ç
Step 2f. #h,V = 1.0 (D.7.2.8 does not apply since h ≥ 1.5c1) D.7.2.8
Step 2g. Calculate V cbg r\ÊÊV cbg r ÊrÊ­ÓÇä]äääÊÉÊ£nä]äää®ÊÝÊ£ÊÝÊ£ÊÝÊ£ÊÝÊ£ÊÝÊÓn°™nÊrÊ{ΰxʎ Ê
D.7.2.1
­ÌiÀ˜>̈Ûi\ÊÊ,iviÀÊ̜Ê>V̜Ài`Êœ>`Ê/>LiÃʈ˜Ê̅ˆÃÊ-Õ««i“i˜Ì®
-Ìi«ÊΰÊ
…iVŽÊv>V̜Ài`Ê«ÀޜÕÌÊÀiÈÃÌ>˜Vi\Ê°Ê
D.7.3.
VcpgrÊrʎcp NcbgrÊrÊÓÊÝÊxn°£{ÊrÊ££È°Ónʎ Ê
-Ìi«Ê{°Ê
œ˜ÌÀœˆ˜}Êv>V̜Ài`ÊÅi>ÀÊÀiÈÃÌ>˜Vi\ÊV r = V c b gr ÊrÊ{ΰxʎ ʀÊNf -

Tension and Shear Interaction Calculations per CSA A23.3-04 Annex D. Code Ref.
-Ìi«Ê£°Ê
…iVŽÊVf ≤ 0.2 Vr
D.8.2.
VfʀÊä°Ó­{ΰx®ÊrÊn°Çʎ ÊÊ­Vf not less than or equal to 0.2 Vr)
-Ìi«ÊÓ°Ê
…iVŽÊNf ≤ 0.2 Nr
D.8.3.
NfʀÊä°Ó­xx°n®ÊrÊ££°Óʎ ÊÊ­Nf not less than or equal to 0.2 Nr)
-Ìi«ÊΰÊ
…iVŽÊNfÊÉÊNr + VfÊÉÊVr ≤ 1.2
D.8.4.
­ÓxÊÉÊxx°n®Ê³Ê­£ÎÊÉÊ{ΰx®ÊrÊä°{{nʳÊä°Ó™™ÊrÊä°Ç{Çʐʣ°ÓÊ→ OK

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 7
Mechanical Anchoring Systems

1.0 HDA Undercut Anchor


Notes for Tension Tables Notes for Shear Tables

£ÊœÀʜ̅iÀÊVœ˜VÀiÌiÊÃÌÀi˜}̅Ã]ʓՏ̈«ÞÊNcbr and Npr by 1 Design strengths in table are for anchors near one edge
corresponding influence of concrete strength factor, fb. only. The values do not apply where the distance to an
edge, measured perpendicular to c1, is less than 1.5c1.
2 The ultimate strength of the anchor steel, futÊrÊnääÊ*>°ÊœÀÊ
Shear force is assumed to act perpendicular, towards the
Stainless Steel, multiply Nsr by 0.875.
edge with no eccentricity.
3 Design strengths in the table are based on resistance
ÓÊœÀʜ̅iÀÊVœ˜VÀiÌiÊÃÌÀi˜}̅Ã]ʓՏ̈«ÞÊVcbr by corresponding
“œ`ˆvˆV>̈œ˜Êv>V̜ÀÊ,]ʜvÊ-iV̈œ˜Ê °x°{°Ê>V̜Ài`ÊÌi˜ÃˆiÊ
influence of concrete strength factor, fb.
load Nf must be computed from the load combinations
referenced in Clause 8.3.2. Design strengths for concrete ÎÊœÀÊ̅iÊÅi>ÀÊÃÌÀi˜}̅ÊÛ>ÕiÃÊvœÀÊ̅iÊ ‡/]ÊÃiiÊ/>LiÊÈ°
LÀi>ŽœÕÌ]ÊNbr, pullout, Npr, and sideface blowout, Nsbr
4 Design strengths in the table are based on resistance
are based on Condition B. Where supplementary
“œ`ˆvˆV>̈œ˜Êv>V̜ÀÊ,]ʜvÊ-iV̈œ˜Ê °x°{°Ê>V̜Ài`ÊÅi>ÀÊ
reinforcement is provided to satisfy Condition A, design
load Vf must be computed from the load combinations
strengths for Nbr and Nsbr may be increased by the ratio
referenced in Clause 8.3.2. Design strengths for
œvÊ, condition A ÊÉÊ, condition B . This increase does not apply to
Vœ˜VÀiÌiÊLÀi>ŽœÕÌ]ÊVbr, are based on Condition B. Where
pullout strength, Npr.
supplementary reinforcement is provided to satisfy
{Ê7…iÀiÊ>˜>ÞÈÃʈ˜`ˆV>ÌiÃÊ̅>ÌÊ̅iÀiÊ܈ÊLiʘœÊVÀ>VŽˆ˜}Ê>ÌÊ Condition A, this design may be increased by the ratio
service load levels (ft < fr) in the region of the anchor, the œvÊ, condition AÊÉÊ, condition B . This increase does not apply to
`iÈ}˜ÊÃÌÀi˜}̅ÃÊvœÀÊVœ˜VÀiÌiÊLÀi>ŽœÕÌʈ˜ÊÌi˜Ãˆœ˜]ÊNbr, may pryout capacities, for which condition B is always assumed.
be increased by #c,N (#c,N = 1.25). See Section D.6.2.6.
xÊ7…iÀiÊ>˜>ÞÈÃʈ˜`ˆV>ÌiÃÊ̅>ÌÊ̅iÀiÊ܈ÊLiʘœÊVÀ>VŽˆ˜}Ê>ÌÊ
xÊ7…iÀiÊ>˜>ÞÈÃʈ˜`ˆV>ÌiÃÊ̅>ÌÊ̅iÀiÊ܈ÊLiʘœÊVÀ>VŽˆ˜}Ê>ÌÊ service load levels (ft < fr) in the region of the anchor, the
service load levels (ft < fr) in the region of the anchor, the `iÈ}˜ÊÃÌÀi˜}̅ÃÊvœÀÊVœ˜VÀiÌiÊLÀi>ŽœÕÌʈ˜ÊÅi>À]ÊVbr, may be
design strengths for concrete pullout in tension, Npr, may be increased by 40%. See Section D.7.2.7.
increased by 40%. See Section D.6.3.6.
ÈÊ/…iÊ`iÈ}˜ÊÃÌÀi˜}̅ÃÊvœÀÊVœ˜VÀiÌiÊLÀi>ŽœÕÌ]ÊVbr, are based
on the shear load being applied perpendicular towards
the edge. If the load is applied parallel to the edge, the
strengths may be increased 100%. See Section D.7.2.1c.

7 Linear interpolation for intermediate values of edge


distance, c1 is permissible.

8 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HDA Undercut Anchor 1.0


Table 1 - Factored resistance for Single HDA anchor subject to Tensile Loads in Cracked Concrete (f ' c = 20 MPa)

Minimum
Min. Nsr - Tension
Embedment Edge 1,3,4 Npr - Nsbr - Sideface
Size Concrete Strength of Ncbr - Tension Breakout (kN)
Depth, hef Distance Pullout1,5 Blowout
Thickness, h
cmin Anchor2

mm mm mm kN c1 - edge distance (mm) kN kN


cmin 100 150 200 250 300 350 400 450

M10 100 170 80 31.6 19.2 21.8 29.1 29.1 29.1 29.1 29.1 29.1 29.1 27.9 N/A
M12 125 190 100 46.0 26.8 34.4 40.6 40.6 40.6 40.6 40.6 40.6 34.9 N/A
M16 190 270 150 85.3 X 49.8 59.0 68.8 76.1 76.1 76.1 76.1 69.8 N/A
M20 250 350 200 133.4 X X 75.8 86.2 97.2 108.9 114.9 114.9 104.7 N/A

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22
35 1.32
40 1.41
45 1.50
50 1.58
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 9
Mechanical Anchoring Systems

1.0 HDA Undercut Anchor


Table 2 - Factored resistance for 2 HDA anchors subject to Tensile Loads in Cracked Concrete (f ' c = 20 MPa)

Nsr - Tension
Spacing, 1,3,4 Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Ncbgr - Tension Breakout of Group (kN)
s Group1,5 of Group
Anchor Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
80 100 150 200 250 300 350 400 450
100 25.6 29.1 38.8 38.8 38.8 38.8 38.8 38.8 38.8
150 28.7 32.7 43.6 43.6 43.6 43.6 43.6 43.6 43.6
200 31.9 36.3 48.4 48.4 48.4 48.4 48.4 48.4 48.4
250 35.1 40.0 53.3 53.3 53.3 53.3 53.3 53.3 53.3
M10 100 170 63.2 300 38.3 43.6 58.1 58.1 58.1 58.1 58.1 58.1 58.1 55.9 N/A
350 38.3 43.6 58.1 58.1 58.1 58.1 58.1 58.1 58.1
400 38.3 43.6 58.1 58.1 58.1 58.1 58.1 58.1 58.1
450 38.3 43.6 58.1 58.1 58.1 58.1 58.1 58.1 58.1
500 38.3 43.6 58.1 58.1 58.1 58.1 58.1 58.1 58.1
cmin
100 150 200 250 300 350 400 450
100 X X X X X X X X
150 37.5 48.1 56.9 56.9 56.9 56.9 56.9 56.9
200 41.1 52.7 62.3 62.3 62.3 62.3 62.3 62.3
250 44.6 57.3 67.7 67.7 67.7 67.7 67.7 67.7
M12 125 190 92.0 300 48.2 61.9 73.1 73.1 73.1 73.1 73.1 73.1 69.8 N/A
350 51.8 66.4 78.5 78.5 78.5 78.5 78.5 78.5
400 53.6 68.7 81.3 81.3 81.3 81.3 81.3 81.3
450 53.6 68.7 81.3 81.3 81.3 81.3 81.3 81.3
500 53.6 68.7 81.3 81.3 81.3 81.3 81.3 81.3
cmin
150 200 250 300 350 400 450
100 X X X X X X X
150 X X X X X X X
200 67.3 79.7 93.0 102.8 102.8 102.8 102.8
250 71.7 84.9 99.0 109.5 109.5 109.5 109.5
M16 190 270 170.6 300 76.1 90.0 105.0 116.2 116.2 116.2 116.2 139.7 N/A
350 80.4 95.2 111.1 122.9 122.9 122.9 122.9
400 84.8 100.4 117.1 129.6 129.6 129.6 129.6
450 89.2 105.5 123.2 136.2 136.2 136.2 136.2
500 93.6 110.7 129.2 142.9 142.9 142.9 142.9
cmin
200 250 300 350 400 450
100 X X X X X X
150 X X X X X X
200 X X X X X X
250 101.0 114.9 129.6 145.1 153.2 153.2
M20 250 350 266.8 300 106.1 120.7 136.1 152.4 160.9 160.9 209.5 N/A
350 111.1 126.4 142.6 159.7 168.5 168.5
400 116.2 132.1 149.1 166.9 176.2 176.2
450 121.2 137.9 155.5 174.2 183.8 183.8
500 126.3 143.6 162.0 181.4 191.5 191.5

Notes:
A. For eccentric loading, multiply Ncbr by the modification factor for eccentrically loaded anchor groups, ec,N as per Section D.6.2.4.
B. If anchors are affected by more than one edge distance use formulas to calculate Concrete Resistance

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12 s
30 1.22
35 1.32
40 1.41
45 1.50
c1
50 1.58
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊn°

10 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HDA Undercut Anchor 1.0


Table 3 - Factored resistance for 4 equally spaced HDA anchors subject to Tensile Loads in Cracked Concrete (f ' c = 20 MPa)

Nsr - Tension
Spacing, 1,3,4 Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Ncbgr - Tension Breakout of Group (kN)
s Group1,5 of Group
Anchor Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
80 100 150 200 250 300 350 400 450
100 36.7 40.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7
150 47.5 52.3 65.4 65.4 65.4 65.4 65.4 65.4 65.4
200 59.7 65.4 80.7 80.7 80.7 80.7 80.7 80.7 80.7
250 73.3 79.9 97.7 97.7 97.7 97.7 97.7 97.7 97.7
M10 100 170 126.4 300 88.3 95.9 116.3 116.3 116.3 116.3 116.3 116.3 116.3 111.7 N/A
350 88.3 95.9 116.3 116.3 116.3 116.3 116.3 116.3 116.3
400 88.3 95.9 116.3 116.3 116.3 116.3 116.3 116.3 116.3
450 88.3 95.9 116.3 116.3 116.3 116.3 116.3 116.3 116.3
500 88.3 95.9 116.3 116.3 116.3 116.3 116.3 116.3 116.3
cmin
100 150 200 250 300 350 400 450
100 X X X X X X X X
150 57.1 69.5 79.6 79.6 79.6 79.6 79.6 79.6
200 69.6 83.9 95.5 95.5 95.5 95.5 95.5 95.5
250 83.5 99.7 112.8 112.8 112.8 112.8 112.8 112.8
M12 125 190 184.0 300 98.5 116.9 131.6 131.6 131.6 131.6 131.6 131.6 139.7 N/A
350 114.8 135.4 151.8 151.8 151.8 151.8 151.8 151.8
400 123.4 145.1 162.5 162.5 162.5 162.5 162.5 162.5
450 123.4 145.1 162.5 162.5 162.5 162.5 162.5 162.5
500 123.4 145.1 162.5 162.5 162.5 162.5 162.5 162.5
cmin
150 200 250 300 350 400 450
100 X X X X X X X
150 X X X X X X X
200 98.3 112.5 127.7 138.9 138.9 138.9 138.9
250 112.9 128.6 145.3 157.6 157.6 157.6 157.6
M16 190 270 341.2 300 128.5 145.7 164.0 177.4 177.4 177.4 177.4 279.3 N/A
350 145.2 163.9 183.8 198.3 198.3 198.3 198.3
400 162.8 183.2 204.7 220.5 220.5 220.5 220.5
450 181.5 203.5 226.7 243.8 243.8 243.8 243.8
500 201.1 224.9 249.9 268.3 268.3 268.3 268.3
cmin
200 250 300 350 400 450
100 X X X X X X
150 X X X X X X
200 X X X X X X
250 144.9 160.9 177.6 195.2 204.3 204.3
M20 250 350 533.6 300 161.4 178.6 196.6 215.5 225.2 225.2 419.0 N/A
350 178.8 197.2 216.5 236.7 247.2 247.2
400 197.0 216.7 237.4 259.0 270.2 270.2
450 216.1 237.2 259.2 282.3 294.2 294.2
500 236.1 258.5 282.0 306.5 319.2 319.2

Notes:
A. For eccentric loading, multiply Ncbr by the modification factor for eccentrically loaded anchor groups, ec,N as per Section D.6.2.4.
B. If anchors are affected by more than one edge distance use formulas to calculate Concrete Resistance

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12 s
30 1.22
35 1.32
40 1.41
45 1.50
c1 s
50 1.58
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 11
Mechanical Anchoring Systems

1.0 HDA Undercut Anchor


Table 4 - Factored resistance for 6 equally spaced HDA anchors subject to Tensile Loads in Cracked Concrete (f ' c = 20 MPa)

Nsr - Tension
Spacing, 1,3,4 Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Ncbgr - Tension Breakout of Group (kN)
s Group1,5 of Group
Anchor Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
80 100 150 200 250 300 350 400 450
100 45.8 50.9 64.6 64.6 64.6 64.6 64.6 64.6 64.6
150 63.3 69.8 87.2 87.2 87.2 87.2 87.2 87.2 87.2
200 83.6 91.6 113.0 113.0 113.0 113.0 113.0 113.0 113.0
250 106.7 116.3 142.1 142.1 142.1 142.1 142.1 142.1 142.1
M10 100 170 189.6 300 132.5 143.9 174.4 174.4 174.4 174.4 174.4 174.4 174.4 167.6 N/A
350 139.9 151.9 174.4 174.4 174.4 174.4 174.4 174.4 174.4
400 147.2 157.0 174.4 174.4 174.4 174.4 174.4 174.4 174.4
450 150.0 157.0 174.4 174.4 174.4 174.4 174.4 174.4 174.4
500 150.0 157.0 174.4 174.4 174.4 174.4 174.4 174.4 174.4
cmin
100 150 200 250 300 350 400 450
100 X X X X X X X X
150 73.4 89.4 102.4 102.4 102.4 102.4 102.4 102.4
200 93.9 113.1 128.7 128.7 128.7 128.7 128.7 128.7
250 116.8 139.6 158.0 158.0 158.0 158.0 158.0 158.0
M12 125 190 276.0 300 142.3 168.8 190.1 190.1 190.1 190.1 190.1 190.1 209.5 N/A
350 170.3 200.7 225.2 225.2 225.2 225.2 225.2 225.2
400 189.3 222.5 243.8 243.8 243.8 243.8 243.8 243.8
450 197.5 229.1 243.8 243.8 243.8 243.8 243.8 243.8
500 205.7 229.1 243.8 243.8 243.8 243.8 243.8 243.8
cmin
150 200 250 300 350 400 450
100 X X X X X X X
150 X X X X X X X
200 123.8 141.8 160.9 175.0 175.0 175.0 175.0
250 147.3 167.8 189.6 205.6 205.6 205.6 205.6
M16 190 270 511.8 300 172.9 196.0 220.5 238.5 238.5 238.5 238.5 419.0 N/A
350 200.4 226.3 253.7 273.8 273.8 273.8 273.8
400 230.0 258.7 289.1 311.4 311.4 311.4 311.4
450 261.5 293.2 326.8 351.3 351.3 351.3 351.3
500 295.1 329.9 366.7 393.6 393.6 393.6 393.6
cmin
200 250 300 350 400 450
100 X X X X X X
150 X X X X X X
200 X X X X X X
250 181.2 201.1 222.0 244.0 255.3 255.3
M20 250 350 800.4 300 207.5 229.6 252.7 277.0 289.6 289.6 628.4 N/A
350 235.6 259.9 285.4 312.0 325.8 325.8
400 265.5 292.1 320.0 349.1 364.1 364.1
450 297.1 326.1 356.4 388.1 404.5 404.5
500 330.5 362.0 394.8 429.2 446.9 446.9

Notes:
A. For eccentric loading, multiply Ncbr by the modification factor for eccentrically loaded anchor groups, ec,N as per Section D.6.2.4.
B. If anchors are affected by more than one edge distance use formulas to calculate Concrete Resistance

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
s
25 1.12
30 1.22
35 1.32
40 1.41
s
45 1.50
50 1.58
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊn° c1 s

12 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HDA Undercut Anchor 1.0


Table 5 - Factored resistance for Single HDA anchor subject to Shear Loads in Cracked Concrete (f'c = 20 MPa)

Vsr - Shear Vsr - Shear


Concrete Vcpr - Pryout
Size hef Strength of Strength of Vcbr - Shear Breakout (kN)1,2,4,5,6,7
Thickness, h Resistance
Anchor3 Anchor3
HDA-P HDA-PR c1 - edge distance (mm) kcp X Ncbr
mm kN kN mm 80 100 150 200 250 300 350 400 450 kN
200 7.3 10.2 17.7 23.7 29.6 35.5 41.4 47.3 53.2
300 7.3 10.2 18.8 29.0 36.2 43.5 50.7 58.0 65.2
M10 100 14.2 17.2 400 7.3 10.2 18.8 29.0 40.5 50.2 58.6 66.9 75.3 2.0 x Ncbr
500 7.3 10.2 18.8 29.0 40.5 53.2 65.5 74.8 84.2
600 7.3 10.2 18.8 29.0 40.5 53.2 67.1 82.0 92.2
675 7.3 10.2 18.8 29.0 40.5 53.2 67.1 82.0 97.8
c1 - edge distance (mm)
100 150 200 250 300 350 400 450
200 11.0 19.1 25.5 31.9 38.2 44.6 51.0 57.4
300 11.0 20.3 31.2 39.0 46.8 54.6 62.4 70.2
M12 125 20.7 25.5 400 11.0 20.3 31.2 43.6 54.1 63.1 72.1 81.1 2.0 x Ncbr
500 11.0 20.3 31.2 43.6 57.4 70.5 80.6 90.7
600 11.0 20.3 31.2 43.6 57.4 72.3 88.3 99.3
675 11.0 20.3 31.2 43.6 57.4 72.3 88.3 105.4
c1 - edge distance (mm)
150 200 250 300 350 400 450
270 24.3 35.5 44.4 53.2 62.1 71.0 79.8
300 24.3 37.4 46.7 56.1 65.4 74.8 84.1
400 24.3 37.4 52.3 64.8 75.6 86.4 97.2
M16 190 38.4 47.8 2.0 x Ncbr
500 24.3 37.4 52.3 68.7 84.5 96.6 108.6
600 24.3 37.4 52.3 68.7 86.6 105.8 119.0
675 24.3 37.4 52.3 68.7 86.6 105.8 126.2
c1 - edge distance (mm)
200 250 300 350 400 450
350 41.8 56.4 67.7 79.0 90.3 101.6
400 41.8 58.4 72.4 84.5 96.5 108.6
M20 250 58.9 N/A 500 41.8 58.4 76.8 94.4 107.9 121.4 2.0 x Ncbr
600 41.8 58.4 76.8 96.8 118.2 133.0
675 41.8 58.4 76.8 96.8 118.2 141.1

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12 V
30 1.22
35 1.32
40 1.41
45 1.50 c1
50 1.58
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 13
Mechanical Anchoring Systems

1.0 HDA Undercut Anchor


Table 6 - Steel Strength in Shear, HDA-T (kN)

Steel
Steel
Strength in
Strength in
Anchor Designation Thickness of fastened part(s) Shear,
Shear,
Seismic
Static (kN)b a,b
(kN)
Carbon Steel Anchors mm in. Vsr Vsr, seismic
10 ≤ t < 15 3/8 ≤ t < 5/8 39.5 35.7
HDA-T 20-M10x100
15 ≤ t < 20 5/8 ≤ t < 13/16 44.6 40.2
10 ≤ t < 15 3/8 ≤ t < 5/8 47.2 42.7
HDA-T 22-M12x125
15 ≤ t < 50 5/8 ≤ t < 2 52.9 47.2
15 ≤ t < 20 5/8 ≤ t < 13/16 86.7 77.8
20 ≤ t < 25 13/16 ≤ t < 1 98.2 88.6
HDA-T 30-M16x190
25 ≤ t < 30 1 ≤ t < 1-3/16 108.4 97.5
30 ≤ t < 60 1-3/16 ≤ t < 2-3/8 117.3 105.2
20 ≤ t < 35 13/16 ≤ t < 1-3/8 128.1 115.4
HDA-T 37-M20x250 35 ≤ t < 50 1-3/8 ≤ t < 2 144.1 129.4
50 ≤ t < 100 2≤t<4 154.9 139.6

Stainless Steel Anchors mm in. Vsr Vsr, seismic


10 ≤ t < 15 3/8 ≤ t < 5/8 44.0 39.5
HDA-TR 20-M10x100
15 ≤ t < 20 5/8 ≤ t < 13/16 45.9 41.4
10 ≤ t < 15 3/8 ≤ t < 5/8 57.4 51.0
HDA-TR 22-M12x125
15 ≤ t < 50 5/8 ≤ t < 2 63.1 56.7
15 ≤ t < 20 5/8 ≤ t < 13/16 101.4 91.2
20 ≤ t < 25 13/16 ≤ t < 1 107.1 96.3
HDA-TR 30-M16x190
25 ≤ t < 30 1 ≤ t < 1-3/16 112.2 100.7
30 ≤ t < 60 1-3/16 ≤ t < 2-3/8 116.0 104.6

a. The nominal steel strength Vsr, seismic for the HDA-P shall be taken from the HDA Design Information Table
b. For groups of anchors, multiply value by number of anchors, n

14 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HDA Undercut Anchor 1.0


Table 7 - Factored resistance for 2 or 4 HDA anchors subject to Shear Loads in Cracked Concrete (f'c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN)1,2,4,5,6,7
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HDA-P HDA-PR c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 10.4 13.7 21.7 27.6 33.5 39.4 45.3 51.3 57.2
150 11.9 15.4 23.7 29.6 35.5 41.4 47.3 53.2 59.1
200 13.4 17.1 25.6 31.5 37.5 43.4 49.3 55.2 61.1
250 14.7 18.8 27.6 33.5 39.4 45.3 51.3 57.2 63.1
M10 100 28.4 56.8 34.4 68.8 200 300 14.7 20.5 29.6 35.5 41.4 47.3 53.2 59.1 65.1 2.0 x Ncbgr
350 14.7 20.5 31.5 37.5 43.4 49.3 55.2 61.1 67.0
400 14.7 20.5 33.5 39.4 45.3 51.3 57.2 63.1 69.0
450 14.7 20.5 35.5 41.4 47.3 53.2 59.1 65.1 71.0
500 14.7 20.5 35.5 43.4 49.3 55.2 61.1 67.0 72.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 10.4 13.7 23.0 33.8 41.0 48.3 55.5 62.8 70.0
150 11.9 15.4 25.1 36.2 43.5 50.7 58.0 65.2 72.4
200 13.4 17.1 27.2 38.6 45.9 53.1 60.4 67.6 74.9
250 14.7 18.8 29.3 41.0 48.3 55.5 62.8 70.0 77.3
M10 100 28.4 56.8 34.4 68.8 300 300 14.7 20.5 31.4 43.5 50.7 58.0 65.2 72.4 79.7 2.0 x Ncbgr
350 14.7 20.5 33.5 45.9 53.1 60.4 67.6 74.9 82.1
400 14.7 20.5 35.5 48.3 55.5 62.8 70.0 77.3 84.5
450 14.7 20.5 37.6 50.7 58.0 65.2 72.4 79.7 86.9
500 14.7 20.5 37.6 53.1 60.4 67.6 74.9 82.1 89.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 10.4 13.7 23.0 33.8 45.9 55.8 64.1 72.5 80.9
150 11.9 15.4 25.1 36.2 48.6 58.6 66.9 75.3 83.6
200 13.4 17.1 27.2 38.6 51.3 61.3 69.7 78.1 86.4
250 14.7 18.8 29.3 41.0 54.0 64.1 72.5 80.9 89.2
M10 100 28.4 56.8 34.4 68.8 400 300 14.7 20.5 31.4 43.5 56.7 66.9 75.3 83.6 92.0 2.0 x Ncbgr
350 14.7 20.5 33.5 45.9 59.4 69.7 78.1 86.4 94.8
400 14.7 20.5 35.5 48.3 62.1 72.5 80.9 89.2 97.6
450 14.7 20.5 37.6 50.7 64.8 75.3 83.6 92.0 100.4
500 14.7 20.5 37.6 53.1 67.5 78.1 86.4 94.8 103.2
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 10.4 13.7 23.0 33.8 45.9 59.1 71.7 81.0 90.4
150 11.9 15.4 25.1 36.2 48.6 62.1 74.8 84.2 93.5
200 13.4 17.1 27.2 38.6 51.3 65.1 77.9 87.3 96.6
250 14.7 18.8 29.3 41.0 54.0 68.0 81.0 90.4 99.8
M10 100 28.4 56.8 34.4 68.8 500 300 14.7 20.5 31.4 43.5 56.7 71.0 84.2 93.5 102.9 2.0 x Ncbgr
350 14.7 20.5 33.5 45.9 59.4 73.9 87.3 96.6 106.0
400 14.7 20.5 35.5 48.3 62.1 76.9 90.4 99.8 109.1
450 14.7 20.5 37.6 50.7 64.8 79.8 93.5 102.9 112.2
500 14.7 20.5 37.6 53.1 67.5 82.8 96.6 106.0 115.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 10.4 13.7 23.0 33.8 45.9 59.1 73.5 88.8 99.0
150 11.9 15.4 25.1 36.2 48.6 62.1 76.7 92.2 102.4
200 13.4 17.1 27.2 38.6 51.3 65.1 79.9 95.6 105.9
250 14.7 18.8 29.3 41.0 54.0 68.0 83.0 99.0 109.3
M10 100 28.4 56.8 34.4 68.8 600 300 14.7 20.5 31.4 43.5 56.7 71.0 86.2 102.4 112.7 2.0 x Ncbgr
350 14.7 20.5 33.5 45.9 59.4 73.9 89.4 105.9 116.1
400 14.7 20.5 35.5 48.3 62.1 76.9 92.6 109.3 119.5
450 14.7 20.5 37.6 50.7 64.8 79.8 95.8 112.7 122.9
500 14.7 20.5 37.6 53.1 67.5 82.8 99.0 116.1 126.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 10.4 13.7 23.0 33.8 45.9 59.1 73.5 88.8 105.0
150 11.9 15.4 25.1 36.2 48.6 62.1 76.7 92.2 108.7
200 13.4 17.1 27.2 38.6 51.3 65.1 79.9 95.6 112.3
250 14.7 18.8 29.3 41.0 54.0 68.0 83.0 99.0 115.9
M10 100 28.4 56.8 34.4 68.8 675 300 14.7 20.5 31.4 43.5 56.7 71.0 86.2 102.4 119.5 2.0 x Ncbgr
350 14.7 20.5 33.5 45.9 59.4 73.9 89.4 105.9 123.1
400 14.7 20.5 35.5 48.3 62.1 76.9 92.6 109.3 126.8
450 14.7 20.5 37.6 50.7 64.8 79.8 95.8 112.7 130.4
500 14.7 20.5 37.6 53.1 67.5 82.8 99.0 116.1 134.0

Influence of Concrete Strength, fb


f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1
c1 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 15
Mechanical Anchoring Systems

1.0 HDA Undercut Anchor


Table 8 - Factored resistance for 2 or 4 HDA anchors subject to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN)1,2,4,5,6,7
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HDA-P HDA-PR c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts 2 Bolts 4 Bolts mm mm 100 150 200 250 300 350 400 450 kN
150 16.6 25.5 31.9 38.2 44.6 51.0 57.4 63.7
200 18.4 27.6 34.0 40.4 46.7 53.1 59.5 65.9
250 20.2 29.7 36.1 42.5 48.9 55.2 61.6 68.0
300 22.1 31.9 38.2 44.6 51.0 57.4 63.7 70.1
M12 125 41.4 82.8 51 102 200 2.0 x Ncbgr
350 22.1 34.0 40.4 46.7 53.1 59.5 65.9 72.2
400 22.1 36.1 42.5 48.9 55.2 61.6 68.0 74.4
450 22.1 38.2 44.6 51.0 57.4 63.7 70.1 76.5
500 22.1 38.2 46.7 53.1 59.5 65.9 72.2 78.6
c1 - edge distance (mm)
100 150 200 250 300 350 400 450
150 16.6 27.0 39.0 46.8 54.6 62.4 70.2 78.1
200 18.4 29.3 41.6 49.4 57.2 65.0 72.8 80.7
250 20.2 31.5 44.2 52.0 59.8 67.6 75.5 83.3
300 22.1 33.8 46.8 54.6 62.4 70.2 78.1 85.9
M12 125 41.4 82.8 51 102 300 2.0 x Ncbgr
350 22.1 36.1 49.4 57.2 65.0 72.8 80.7 88.5
400 22.1 38.3 52.0 59.8 67.6 75.5 83.3 91.1
450 22.1 40.6 54.6 62.4 70.2 78.1 85.9 93.7
500 22.1 40.6 57.2 65.0 72.8 80.7 88.5 96.3
c1 - edge distance (mm)
100 150 200 250 300 350 400 450
150 16.6 27.0 39.0 52.4 63.1 72.1 81.1 90.1
200 18.4 29.3 41.6 55.3 66.1 75.1 84.1 93.1
250 20.2 31.5 44.2 58.2 69.1 78.1 87.1 96.1
300 22.1 33.8 46.8 61.1 72.1 81.1 90.1 99.1
M12 125 41.4 82.8 51 102 400 2.0 x Ncbgr
350 22.1 36.1 49.4 64.0 75.1 84.1 93.1 102.1
400 22.1 38.3 52.0 66.9 78.1 87.1 96.1 105.1
450 22.1 40.6 54.6 69.8 81.1 90.1 99.1 108.2
500 22.1 40.6 57.2 72.7 84.1 93.1 102.1 111.2
c1 - edge distance (mm)
100 150 200 250 300 350 400 450
150 16.6 27.0 39.0 52.4 66.9 80.6 90.7 100.8
200 18.4 29.3 41.6 55.3 70.1 84.0 94.0 104.1
250 20.2 31.5 44.2 58.2 73.3 87.3 97.4 107.5
300 22.1 33.8 46.8 61.1 76.5 90.7 100.8 110.8
M12 125 41.4 82.8 51 102 500 2.0 x Ncbgr
350 22.1 36.1 49.4 64.0 79.7 94.0 104.1 114.2
400 22.1 38.3 52.0 66.9 82.8 97.4 107.5 117.6
450 22.1 40.6 54.6 69.8 86.0 100.8 110.8 120.9
500 22.1 40.6 57.2 72.7 89.2 104.1 114.2 124.3
c1 - edge distance (mm)
100 150 200 250 300 350 400 450
150 16.6 27.0 39.0 52.4 66.9 82.6 99.3 110.4
200 18.4 29.3 41.6 55.3 70.1 86.0 103.0 114.1
250 20.2 31.5 44.2 58.2 73.3 89.5 106.7 117.7
300 22.1 33.8 46.8 61.1 76.5 92.9 110.4 121.4
M12 125 41.4 82.8 51 102 600 2.0 x Ncbgr
350 22.1 36.1 49.4 64.0 79.7 96.4 114.1 125.1
400 22.1 38.3 52.0 66.9 82.8 99.8 117.7 128.8
450 22.1 40.6 54.6 69.8 86.0 103.3 121.4 132.5
500 22.1 40.6 57.2 72.7 89.2 106.7 125.1 136.1
c1 - edge distance (mm)
100 150 200 250 300 350 400 450
150 16.6 27.0 39.0 52.4 66.9 82.6 99.3 117.1
200 18.4 29.3 41.6 55.3 70.1 86.0 103.0 121.0
250 20.2 31.5 44.2 58.2 73.3 89.5 106.7 124.9
300 22.1 33.8 46.8 61.1 76.5 92.9 110.4 128.8
M12 125 41.4 82.8 51 102 675 2.0 x Ncbgr
350 22.1 36.1 49.4 64.0 79.7 96.4 114.1 132.7
400 22.1 38.3 52.0 66.9 82.8 99.8 117.7 136.6
450 22.1 40.6 54.6 69.8 86.0 103.3 121.4 140.5
500 22.1 40.6 57.2 72.7 89.2 106.7 125.1 144.4

Influence of Concrete Strength, fb


f 'c (MPa) fb
20 1.00
25 1.12
30 1.22
35 1.32
s V s V
40 1.41
45 1.50
50 1.58
55 1.66
c1 s
c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊn°

16 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HDA Undercut Anchor 1.0


Table 9 - Factored resistance for 2 or 4 HDA anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HDA-P HDA-PR c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts 2 Bolts 4 Bolts mm mm 150 200 250 300 350 400 450 kN
200 35.1 47.3 56.2 65.0 73.9 82.8 91.7
250 37.8 50.3 59.1 68.0 76.9 85.7 94.6
300 40.5 53.2 62.1 71.0 79.8 88.7 97.6
M16 190 76.8 153.6 95.6 191.2 270 350 43.2 56.2 65.0 73.9 82.8 91.7 100.5 2.0 x Ncbgr
400 45.9 59.1 68.0 76.9 85.7 94.6 103.5
450 48.6 62.1 71.0 79.8 88.7 97.6 106.4
500 48.6 65.0 73.9 82.8 91.7 100.5 109.4
c1 - edge distance (mm)
150 200 250 300 350 400 450
200 35.1 49.9 59.2 68.6 77.9 87.3 96.6
250 37.8 53.0 62.3 71.7 81.0 90.4 99.7
300 40.5 56.1 65.4 74.8 84.1 93.5 102.8
M16 190 76.8 153.6 95.6 191.2 300 350 43.2 59.2 68.6 77.9 87.3 96.6 106.0 2.0 x Ncbgr
400 45.9 62.3 71.7 81.0 90.4 99.7 109.1
450 48.6 65.4 74.8 84.1 93.5 102.8 112.2
500 48.6 68.6 77.9 87.3 96.6 106.0 115.3
c1 - edge distance (mm)
150 200 250 300 350 400 450
200 35.1 49.9 66.2 79.2 90.0 100.8 111.6
250 37.8 53.0 69.7 82.8 93.6 104.4 115.2
300 40.5 56.1 73.2 86.4 97.2 108.0 118.8
M16 190 76.8 153.6 95.6 191.2 400 350 43.2 59.2 76.7 90.0 100.8 111.6 122.4 2.0 x Ncbgr
400 45.9 62.3 80.1 93.6 104.4 115.2 126.0
450 48.6 65.4 83.6 97.2 108.0 118.8 129.6
500 48.6 68.6 87.1 100.8 111.6 122.4 133.2
c1 - edge distance (mm)
150 200 250 300 350 400 450
200 35.1 49.9 66.2 84.0 100.6 112.7 124.7
250 37.8 53.0 69.7 87.8 104.6 116.7 128.8
300 40.5 56.1 73.2 91.6 108.6 120.7 132.8
M16 190 76.8 153.6 95.6 191.2 500 350 43.2 59.2 76.7 95.4 112.7 124.7 136.8 2.0 x Ncbgr
400 45.9 62.3 80.1 99.2 116.7 128.8 140.8
450 48.6 65.4 83.6 103.1 120.7 132.8 144.8
500 48.6 68.6 87.1 106.9 124.7 136.8 148.9
c1 - edge distance (mm)
150 200 250 300 350 400 450
200 35.1 49.9 66.2 84.0 103.1 123.4 136.6
250 37.8 53.0 69.7 87.8 107.2 127.8 141.0
300 40.5 56.1 73.2 91.6 111.3 132.2 145.5
M16 190 76.8 153.6 95.6 191.2 600 350 43.2 59.2 76.7 95.4 115.4 136.6 149.9 2.0 x Ncbgr
400 45.9 62.3 80.1 99.2 119.6 141.0 154.3
450 48.6 65.4 83.6 103.1 123.7 145.5 158.7
500 48.6 68.6 87.1 106.9 127.8 149.9 163.1
c1 - edge distance (mm)
150 200 250 300 350 400 450
200 35.1 49.9 66.2 84.0 103.1 123.4 144.9
250 37.8 53.0 69.7 87.8 107.2 127.8 149.6
300 40.5 56.1 73.2 91.6 111.3 132.2 154.3
M16 190 76.8 153.6 95.6 191.2 675 350 43.2 59.2 76.7 95.4 115.4 136.6 158.9 2.0 x Ncbgr
400 45.9 62.3 80.1 99.2 119.6 141.0 163.6
450 48.6 65.4 83.6 103.1 123.7 145.5 168.3
500 48.6 68.6 87.1 106.9 127.8 149.9 173.0

Influence of Concrete Strength, fb


f 'c (MPa) fb
20 1.00
25 1.12
30 1.22
35 1.32 s V s V
40 1.41
45 1.50
50 1.58
55 1.66
c1 s
c1
IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 17
Mechanical Anchoring Systems

1.0 HDA Undercut Anchor


Table 10 - Factored resistance for 2 or 4 HDA anchors subject to Shear Loads in Cracked Concrete (f'c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN)1,2,4,5,6,7
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HDA-P HDA-PR c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts 2 Bolts 4 Bolts mm mm 200 250 300 350 400 450 kN
250 59.2 75.3 86.5 97.8 109.1 120.4
300 62.7 79.0 90.3 101.6 112.9 124.2
350 66.2 82.8 94.1 105.4 116.6 127.9 2.0 x Ncbgr
M20 250 117.8 235.6 N/A N/A 350
400 69.7 86.5 97.8 109.1 120.4 131.7
450 73.2 90.3 101.6 112.9 124.2 135.5
500 76.6 94.1 105.4 116.6 127.9 139.2
c1 - edge distance (mm)
200 250 300 350 400 450
250 59.2 77.9 92.5 104.6 116.7 128.7
300 62.7 81.8 96.5 108.6 120.7 132.7
350 66.2 85.7 100.6 112.6 124.7 136.8 2.0 x Ncbgr
M20 250 117.8 235.6 N/A N/A 400
400 69.7 89.6 104.6 116.7 128.7 140.8
450 73.2 93.5 108.6 120.7 132.7 144.8
500 76.6 97.4 112.6 124.7 136.8 148.8
c1 - edge distance (mm)
200 250 300 350 400 450
250 59.2 77.9 98.1 116.9 130.4 143.9
300 62.7 81.8 102.4 121.4 134.9 148.4
350 66.2 85.7 106.7 125.9 139.4 152.9
M20 250 117.8 235.6 N/A N/A 500 2.0 x Ncbgr
400 69.7 89.6 110.9 130.4 143.9 157.4
450 73.2 93.5 115.2 134.9 148.4 161.9
500 76.6 97.4 119.5 139.4 152.9 166.4
c1 - edge distance (mm)
200 250 300 350 400 450
250 59.2 77.9 98.1 119.8 142.9 157.6
300 62.7 81.8 102.4 124.4 147.8 162.6
350 66.2 85.7 106.7 129.0 152.7 167.5
M20 250 117.8 235.6 N/A N/A 600 2.0 x Ncbgr
400 69.7 89.6 110.9 133.6 157.6 172.4
450 73.2 93.5 115.2 138.3 162.6 177.4
500 76.6 97.4 119.5 142.9 167.5 182.3
c1 - edge distance (mm)
200 250 300 350 400 450
250 59.2 77.9 98.1 119.8 142.9 167.2
300 62.7 81.8 102.4 124.4 147.8 172.4
350 66.2 85.7 106.7 129.0 152.7 177.7
M20 250 117.8 235.6 N/A N/A 675 2.0 x Ncbgr
400 69.7 89.6 110.9 133.6 157.6 182.9
450 73.2 93.5 115.2 138.3 162.6 188.1
500 76.6 97.4 119.5 142.9 167.5 193.3

Influence of Concrete Strength, fb


f 'c (MPa) fb
20 1.00
25 1.12
30 1.22
35 1.32 s V s V
40 1.41
45 1.50
50 1.58
55 1.66
c1 s
c1
IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊn°

18 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HDA Undercut Anchor 1.0


Table 11 - Factored resistance for 3 or 6 HDA anchors subject to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN)1,2,4,5,6,7
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HDA-P HDA-PR c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 13.4 17.1 25.6 31.5 37.5 43.4 49.3 55.2 61.1
150 16.5 20.5 29.6 35.5 41.4 47.3 53.2 59.1 65.1
200 19.5 23.9 33.5 39.4 45.3 51.3 57.2 63.1 69.0
250 22.0 27.3 37.5 43.4 49.3 55.2 61.1 67.0 72.9
M10 100 42.6 85.2 51.6 103.2 200 300 22.0 30.7 41.4 47.3 53.2 59.1 65.1 71.0 76.9 2.0 x Ncbgr
350 22.0 30.7 45.3 51.3 57.2 63.1 69.0 74.9 80.8
400 22.0 30.7 49.3 55.2 61.1 67.0 72.9 78.9 84.8
450 22.0 30.7 53.2 59.1 65.1 71.0 76.9 82.8 88.7
500 22.0 30.7 53.2 63.1 69.0 74.9 80.8 86.7 92.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 13.4 17.1 27.2 38.6 45.9 53.1 60.4 67.6 74.9
150 16.5 20.5 31.4 43.5 50.7 58.0 65.2 72.4 79.7
200 19.5 23.9 35.5 48.3 55.5 62.8 70.0 77.3 84.5
250 22.0 27.3 39.7 53.1 60.4 67.6 74.9 82.1 89.3
M10 100 42.6 85.2 51.6 103.2 300 300 22.0 30.7 43.9 58.0 65.2 72.4 79.7 86.9 94.2 2.0 x Ncbgr
350 22.0 30.7 48.1 62.8 70.0 77.3 84.5 91.8 99.0
400 22.0 30.7 52.3 67.6 74.9 82.1 89.3 96.6 103.8
450 22.0 30.7 56.5 72.4 79.7 86.9 94.2 101.4 108.7
500 22.0 30.7 56.5 77.3 84.5 91.8 99.0 106.2 113.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 13.4 17.1 27.2 38.6 51.3 61.3 69.7 78.1 86.4
150 16.5 20.5 31.4 43.5 56.7 66.9 75.3 83.6 92.0
200 19.5 23.9 35.5 48.3 62.1 72.5 80.9 89.2 97.6
250 22.0 27.3 39.7 53.1 67.5 78.1 86.4 94.8 103.2
M10 100 42.6 85.2 51.6 103.2 400 300 22.0 30.7 43.9 58.0 72.9 83.6 92.0 100.4 108.7 2.0 x Ncbgr
350 22.0 30.7 48.1 62.8 78.3 89.2 97.6 105.9 114.3
400 22.0 30.7 52.3 67.6 83.7 94.8 103.2 111.5 119.9
450 22.0 30.7 56.5 72.4 89.1 100.4 108.7 117.1 125.5
500 22.0 30.7 56.5 77.3 94.5 105.9 114.3 122.7 131.0
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 13.4 17.1 27.2 38.6 51.3 65.1 77.9 87.3 96.6
150 16.5 20.5 31.4 43.5 56.7 71.0 84.2 93.5 102.9
200 19.5 23.9 35.5 48.3 62.1 76.9 90.4 99.8 109.1
250 22.0 27.3 39.7 53.1 67.5 82.8 96.6 106.0 115.3
M10 100 42.6 85.2 51.6 103.2 500 300 22.0 30.7 43.9 58.0 72.9 88.7 102.9 112.2 121.6 2.0 x Ncbgr
350 22.0 30.7 48.1 62.8 78.3 94.6 109.1 118.5 127.8
400 22.0 30.7 52.3 67.6 83.7 100.5 115.3 124.7 134.0
450 22.0 30.7 56.5 72.4 89.1 106.5 121.6 130.9 140.3
500 22.0 30.7 56.5 77.3 94.5 112.4 127.8 137.2 146.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 13.4 17.1 27.2 38.6 51.3 65.1 79.9 95.6 105.9
150 16.5 20.5 31.4 43.5 56.7 71.0 86.2 102.4 112.7
200 19.5 23.9 35.5 48.3 62.1 76.9 92.6 109.3 119.5
250 22.0 27.3 39.7 53.1 67.5 82.8 99.0 116.1 126.3
M10 100 42.6 85.2 51.6 103.2 600 300 22.0 30.7 43.9 58.0 72.9 88.7 105.4 122.9 133.2 2.0 x Ncbgr
350 22.0 30.7 48.1 62.8 78.3 94.6 111.8 129.8 140.0
400 22.0 30.7 52.3 67.6 83.7 100.5 118.2 136.6 146.8
450 22.0 30.7 56.5 72.4 89.1 106.5 124.6 143.4 153.7
500 22.0 30.7 56.5 77.3 94.5 112.4 131.0 150.2 160.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 13.4 17.1 27.2 38.6 51.3 65.1 79.9 95.6 112.3
150 16.5 20.5 31.4 43.5 56.7 71.0 86.2 102.4 119.5
200 19.5 23.9 35.5 48.3 62.1 76.9 92.6 109.3 126.8
250 22.0 27.3 39.7 53.1 67.5 82.8 99.0 116.1 134.0
M10 100 42.6 85.2 51.6 103.2 675 300 22.0 30.7 43.9 58.0 72.9 88.7 105.4 122.9 141.3 2.0 x Ncbgr
350 22.0 30.7 48.1 62.8 78.3 94.6 111.8 129.8 148.5
400 22.0 30.7 52.3 67.6 83.7 100.5 118.2 136.6 155.7
450 22.0 30.7 56.5 72.4 89.1 106.5 124.6 143.4 163.0
500 22.0 30.7 56.5 77.3 94.5 112.4 131.0 150.2 170.2

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s s
35 1.32
40 1.41 V V
45 1.50
50 1.58 s s
55 1.66

c1 c1 s

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 19
Mechanical Anchoring Systems

1.0 HDA Undercut Anchor


Table 12 - Factored resistance for 3 or 6 HDA anchors subject to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete 1,2,4,5,6,7 Vcpgr - Pryout
Size hef 3 Spacing, s Vcbgr - Shear Breakout (kN)
Anchor (kN) Anchor (kN)3 Thickness, h Resistance

HDA-P HDA-PR c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts 3 Bolts 6 Bolts mm mm 100 150 200 250 300 350 400 450 kN
150 22.1 31.9 38.2 44.6 51.0 57.4 63.7 70.1
200 25.8 36.1 42.5 48.9 55.2 61.6 68.0 74.4
250 29.4 40.4 46.7 53.1 59.5 65.9 72.2 78.6
300 33.1 44.6 51.0 57.4 63.7 70.1 76.5 82.8 2.0 x Ncbgr
M12 125 62.1 124.2 76.5 153 200
350 33.1 48.9 55.2 61.6 68.0 74.4 80.7 87.1
400 33.1 53.1 59.5 65.9 72.2 78.6 85.0 91.3
450 33.1 57.4 63.7 70.1 76.5 82.8 89.2 95.6
500 33.1 57.4 68.0 74.4 80.7 87.1 93.5 99.8
c1 - edge distance (mm)
100 150 200 250 300 350 400 450
150 22.1 33.8 46.8 54.6 62.4 70.2 78.1 85.9
200 25.8 38.3 52.0 59.8 67.6 75.5 83.3 91.1
250 29.4 42.8 57.2 65.0 72.8 80.7 88.5 96.3
300 33.1 47.3 62.4 70.2 78.1 85.9 93.7 101.5 2.0 x Ncbgr
M12 125 62.1 124.2 76.5 153 300
350 33.1 51.8 67.6 75.5 83.3 91.1 98.9 106.7
400 33.1 56.3 72.8 80.7 88.5 96.3 104.1 111.9
450 33.1 60.8 78.1 85.9 93.7 101.5 109.3 117.1
500 33.1 60.8 83.3 91.1 98.9 106.7 114.5 122.3
c1 - edge distance (mm)
100 150 200 250 300 350 400 450
150 22.1 33.8 46.8 61.1 72.1 81.1 90.1 99.1
200 25.8 38.3 52.0 66.9 78.1 87.1 96.1 105.1
250 29.4 42.8 57.2 72.7 84.1 93.1 102.1 111.2
300 33.1 47.3 62.4 78.5 90.1 99.1 108.2 117.2 2.0 x Ncbgr
M12 125 62.1 124.2 76.5 153 400
350 33.1 51.8 67.6 84.4 96.1 105.1 114.2 123.2
400 33.1 56.3 72.8 90.2 102.1 111.2 120.2 129.2
450 33.1 60.8 78.1 96.0 108.2 117.2 126.2 135.2
500 33.1 60.8 83.3 101.8 114.2 123.2 132.2 141.2
c1 - edge distance (mm)
100 150 200 250 300 350 400 450
150 22.1 33.8 46.8 61.1 76.5 90.7 100.8 110.8
200 25.8 38.3 52.0 66.9 82.8 97.4 107.5 117.6
250 29.4 42.8 57.2 72.7 89.2 104.1 114.2 124.3
300 33.1 47.3 62.4 78.5 95.6 110.8 120.9 131.0
M12 125 62.1 124.2 76.5 153 500 2.0 x Ncbgr
350 33.1 51.8 67.6 84.4 102.0 117.6 127.6 137.7
400 33.1 56.3 72.8 90.2 108.3 124.3 134.4 144.4
450 33.1 60.8 78.1 96.0 114.7 131.0 141.1 151.1
500 33.1 60.8 83.3 101.8 121.1 137.7 147.8 157.9
c1 - edge distance (mm)
100 150 200 250 300 350 400 450
150 22.1 33.8 46.8 61.1 76.5 92.9 110.4 121.4
200 25.8 38.3 52.0 66.9 82.8 99.8 117.7 128.8
250 29.4 42.8 57.2 72.7 89.2 106.7 125.1 136.1
300 33.1 47.3 62.4 78.5 95.6 113.6 132.5 143.5
M12 125 62.1 124.2 76.5 153 600 2.0 x Ncbgr
350 33.1 51.8 67.6 84.4 102.0 120.5 139.8 150.9
400 33.1 56.3 72.8 90.2 108.3 127.3 147.2 158.2
450 33.1 60.8 78.1 96.0 114.7 134.2 154.5 165.6
500 33.1 60.8 83.3 101.8 121.1 141.1 161.9 172.9
c1 - edge distance (mm)
100 150 200 250 300 350 400 450
150 22.1 33.8 46.8 61.1 76.5 92.9 110.4 128.8
200 25.8 38.3 52.0 66.9 82.8 99.8 117.7 136.6
250 29.4 42.8 57.2 72.7 89.2 106.7 125.1 144.4
300 33.1 47.3 62.4 78.5 95.6 113.6 132.5 152.2
M12 125 62.1 124.2 76.5 153 675 2.0 x Ncbgr
350 33.1 51.8 67.6 84.4 102.0 120.5 139.8 160.0
400 33.1 56.3 72.8 90.2 108.3 127.3 147.2 167.8
450 33.1 60.8 78.1 96.0 114.7 134.2 154.5 175.6
500 33.1 60.8 83.3 101.8 121.1 141.1 161.9 183.4

Influence of Concrete Strength, fb


f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s s
35 1.32
40
45
1.41
1.50
V V
50 1.58
s s
55 1.66

c1 c1 s

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊn°

20 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HDA Undercut Anchor 1.0


Table 13 - Factored resistance for 3 or 6 HDA anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HDA-P HDA-PR c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts 3 Bolts 6 Bolts mm mm 150 200 250 300 350 400 450 kN
200 45.9 59.1 68.0 76.9 85.7 94.6 103.5
250 51.3 65.0 73.9 82.8 91.7 100.5 109.4
300 56.7 71.0 79.8 88.7 97.6 106.4 115.3
M16 190 115.2 230.4 143.4 286.8 270 350 62.1 76.9 85.7 94.6 103.5 112.4 121.2 2.0 x Ncbgr
400 67.5 82.8 91.7 100.5 109.4 118.3 127.1
450 72.9 88.7 97.6 106.4 115.3 124.2 133.1
500 72.9 94.6 103.5 112.4 121.2 130.1 139.0
c1 - edge distance (mm)
150 200 250 300 350 400 450
200 45.9 62.3 71.7 81.0 90.4 99.7 109.1
250 51.3 68.6 77.9 87.3 96.6 106.0 115.3
300 56.7 74.8 84.1 93.5 102.8 112.2 121.5
M16 190 115.2 230.4 143.4 286.8 300 350 62.1 81.0 90.4 99.7 109.1 118.4 127.8 2.0 x Ncbgr
400 67.5 87.3 96.6 106.0 115.3 124.7 134.0
450 72.9 93.5 102.8 112.2 121.5 130.9 140.2
500 72.9 99.7 109.1 118.4 127.8 137.1 146.5
c1 - edge distance (mm)
150 200 250 300 350 400 450
200 45.9 62.3 80.1 93.6 104.4 115.2 126.0
250 51.3 68.6 87.1 100.8 111.6 122.4 133.2
300 56.7 74.8 94.1 108.0 118.8 129.6 140.4
M16 190 115.2 230.4 143.4 286.8 400 350 62.1 81.0 101.1 115.2 126.0 136.8 147.6 2.0 x Ncbgr
400 67.5 87.3 108.0 122.4 133.2 144.0 154.7
450 72.9 93.5 115.0 129.6 140.4 151.2 161.9
500 72.9 99.7 122.0 136.8 147.6 158.3 169.1
c1 - edge distance (mm)
150 200 250 300 350 400 450
200 45.9 62.3 80.1 99.2 116.7 128.8 140.8
250 51.3 68.6 87.1 106.9 124.7 136.8 148.9
300 56.7 74.8 94.1 114.5 132.8 144.8 156.9
M16 190 115.2 230.4 143.4 286.8 500 350 62.1 81.0 101.1 122.1 140.8 152.9 165.0 2.0 x Ncbgr
400 67.5 87.3 108.0 129.8 148.9 160.9 173.0
450 72.9 93.5 115.0 137.4 156.9 169.0 181.1
500 72.9 99.7 122.0 145.1 165.0 177.0 189.1
c1 - edge distance (mm)
150 200 250 300 350 400 450
200 45.9 62.3 80.1 99.2 119.6 141.0 154.3
250 51.3 68.6 87.1 106.9 127.8 149.9 163.1
300 56.7 74.8 94.1 114.5 136.1 158.7 171.9
M16 190 115.2 230.4 143.4 286.8 600 350 62.1 81.0 101.1 122.1 144.3 167.5 180.7 2.0 x Ncbgr
400 67.5 87.3 108.0 129.8 152.5 176.3 189.5
450 72.9 93.5 115.0 137.4 160.8 185.1 198.3
500 72.9 99.7 122.0 145.1 169.0 193.9 207.2
c1 - edge distance (mm)
150 200 250 300 350 400 450
200 45.9 62.3 80.1 99.2 119.6 141.0 163.6
250 51.3 68.6 87.1 106.9 127.8 149.9 173.0
300 56.7 74.8 94.1 114.5 136.1 158.7 182.3
M16 190 115.2 230.4 143.4 286.8 675 350 62.1 81.0 101.1 122.1 144.3 167.5 191.7 2.0 x Ncbgr
400 67.5 87.3 108.0 129.8 152.5 176.3 201.0
450 72.9 93.5 115.0 137.4 160.8 185.1 210.4
500 72.9 99.7 122.0 145.1 169.0 193.9 219.7

Influence of Concrete Strength, fb


f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s s
35 1.32
40 1.41
45 1.50
V V
50 1.58
55 1.66 s s

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊn°
c1 c1 s

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 21
Mechanical Anchoring Systems

1.0 HDA Undercut Anchor

Table 14 - Factored resistance for 3 or 6 HDA anchors subject to Shear Loads in Cracked Concrete (f'c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN)1,2,4,5,6,7
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HDA-P HDA-PR c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts 3 Bolts 6 Bolts mm mm 200 250 300 350 400 450 kN
250 76.6 94.1 105.4 116.6 127.9 139.2
300 83.6 101.6 112.9 124.2 135.5 146.7
350 90.6 109.1 120.4 131.7 143.0 154.3 2.0 x Ncbgr
M20 250 176.7 353.4 N/A N/A 350
400 97.5 116.6 127.9 139.2 150.5 161.8
450 104.5 124.2 135.5 146.7 158.0 169.3
500 111.5 131.7 143.0 154.3 165.6 176.8
c1 - edge distance (mm)
200 250 300 350 400 450
250 76.6 97.4 112.6 124.7 136.8 148.8
300 83.6 105.2 120.7 132.7 144.8 156.9
350 90.6 112.9 128.7 140.8 152.9 164.9
M20 250 176.7 353.4 N/A N/A 400 2.0 x Ncbgr
400 97.5 120.7 136.8 148.8 160.9 173.0
450 104.5 128.5 144.8 156.9 168.9 181.0
500 111.5 136.3 152.9 164.9 177.0 189.1
c1 - edge distance (mm)
200 250 300 350 400 450
250 76.6 97.4 119.5 139.4 152.9 166.4
300 83.6 105.2 128.0 148.4 161.9 175.4
350 90.6 112.9 136.5 157.4 170.9 184.4 2.0 x Ncbgr
M20 250 176.7 353.4 N/A N/A 500
400 97.5 120.7 145.1 166.4 179.9 193.4
450 104.5 128.5 153.6 175.4 188.9 202.4
500 111.5 136.3 162.1 184.4 197.9 211.4
c1 - edge distance (mm)
200 250 300 350 400 450
250 76.6 97.4 119.5 142.9 167.5 182.3
300 83.6 105.2 128.0 152.1 177.4 192.1
350 90.6 112.9 136.5 161.3 187.2 202.0 2.0 x Ncbgr
M20 250 176.7 353.4 N/A N/A 600
400 97.5 120.7 145.1 170.5 197.1 211.8
450 104.5 128.5 153.6 179.7 206.9 221.7
500 111.5 136.3 162.1 188.9 216.8 231.5
c1 - edge distance (mm)
200 250 300 350 400 450
250 76.6 97.4 119.5 142.9 167.5 193.3
300 83.6 105.2 128.0 152.1 177.4 203.8
350 90.6 112.9 136.5 161.3 187.2 214.2
M20 250 176.7 353.4 N/A N/A 675 2.0 x Ncbgr
400 97.5 120.7 145.1 170.5 197.1 224.7
450 104.5 128.5 153.6 179.7 206.9 235.1
500 111.5 136.3 162.1 188.9 216.8 245.6

Influence of Concrete Strength, fb

f'c (MPa) fb
20 1.00
25 1.12 s
30 1.22 s
35 1.32
40 1.41
V V
45 1.50 s s
50 1.58
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊn°

22 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HDA Undercut Anchor 1.0

1.4 Installation Instructions


Setting Operation HDA-P/-PR/-PF (Pre-Set Style)

1. Drill a hole to the required depth using a stop drill bit 2. Clean hole with compressed air or a hand air pump 3. Insert the anchor into the hole by hand, so that the
matched to the anchor, (refer to specification table such that drilling debris is evacuated. cone sits on the bottom of the drilled hole. Do not
and ordering info.). If rebar is encountered, use a Hilti remove the plastic cap which protects the threaded
metric matched tolerance diamond core bit to drill rod. Using the assigned setting tool and Hilti hammer
through the rebar. Remove the concrete core and drill, the setting tool is guided over the anchor rod
finish drilling the hole with the stop drill bit. Always and engages the grooves in the sleeve. It is critical
consult with the Engineer of Record before cutting to use the specified Hilti hammer drills.
rebar.

4. The anchor is set with the specified 5. The anchor is correctly set and the 6. Remove the plastic thread protector cap. Secure the
Hilti hammer drill in hammer drill mode undercut is fully formed when the red part to be fastened by using the conical spring wash-
and in the specified gear. During the setting mark on the anchor bolt is visible above the er and nut provided. Apply a torque not to exceed
procedure, both drilling and impact energy are top edge of the sleeve. The top edge of the the maximum values given in the Specification Table.
transferred to the sleeve by the setting tool, causing anchor sleeve must be positioned approx. 3mm Torque is not required to set the anchor.
the sleeve to slide over the conical end of the anchor below the concrete surface. If the anchor setting time
bolt while forming the undercut in the base material. exceeds 60 seconds for M10, M12 or M16 anchors
On the setting tool, the red ring indicates the progress or 120 seconds for M20 anchors the installation
of the setting operation. When this marking is flush failed and the anchors must not be loaded.
with the concrete surface, check the anchor for
proper setting (refer to step 5).

Setting Operation HDA-T/-TR/-TF (Through-Set Style)

1. Drill a hole to the required depth using a stop drill bit 2. Clean hole with compressed air or a hand air pump 3. Insert the anchor into the hole by hand, so that the
matched to the anchor, (refer to specification table such that drilling debris is evacuated. cone sits on the bottom of the drilled hole. Do not
and ordering info.). If rebar is encountered, use a Hilti remove the plastic cap which protects the threaded
metric matched tolerance diamond core bit to drill rod. Using the assigned setting tool and Hilti hammer
through the rebar. Remove the concrete core and fin- drill, the setting tool is guided over the anchor rod
ish drilling the hole with the stop drill bit. Always con- and engages the grooves in the sleeve. It is critical
sult with the Engineer of Record before cutting rebar. to use the specified Hilti hammer drills.

4. The anchor is set with the specified 5. The anchor is set and the 6. Remove the plastic thread protector cap. Secure the
Hiltli hammer drill in hammer drill undercut is fully formed when the part to be fastened by using the conical spring wash-
mode and in the specified gear. During red marking on the anchor bolt is visible er and nut provided. Apply a torque not to exceed
the setting procedure, both drilling and above the top edge of the sleeve. The top the maximum values given in the Specification Table.
impact energy are transferred to the sleeve by edge of the anchor sleeve must be positioned Torque is not required to set the anchor.
the setting tool, causing the sleeve to slide over approx. 3mm below the surface of the fixture. If
the conical end of the anchor bolt while forming the anchor setting time exceeds 60 seconds for M10,
undercut in the base material. On the setting tool, M12 or M16 anchors or 120 seconds for M20
the red ring indicates the progress of the setting anchors the installation failed and the anchor
operation. When this marking is flush with the con- must not be loaded.
nected part, check the anchor for proper setting (refer
to step 5).

The HDA Undercut Anchor, designed to carry significant, safety-relevant loads, must be installed correctly with the prescribed tools
to function properly. Carefully follow all instructions located inside the box. Installer training is also available upon request.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 23
Mechanical Anchoring Systems

1.0 HDA Undercut Anchor


Equipment required for setting HDA Anchors
HDA carbon steel - zinc plated
Anchor Hilti Hammer Drill Stop drill bit Setting tool
TE 56/
TE 80 ATC-AVR Single impact
TE RPM under
TE 25
56-
TE 75 TE 70/TE 70-ATC energy for
(1st TE 35
TE 40-
TE 76/TE 76-ATC load (1/min)
AVR ATC setting
gear)
max impact energy

s s TE-C-HDA-B 20x100 TE-C-HDA-ST 20 M10 3.7 - 4.7 250 - 500


HDA-P 20-M10x100/20
s TE-Y-HDA-B 20x100 TE-Y-HDA-ST 20 M10 6.5 - 7.5 480 - 500
s s TE-C-HDA-B 20x120 TE-C-HDA-ST 20 M10 3.7 - 4.7 250 - 500
HDA-T 20-M10x100/20
s TE-Y-HDA-B 20x120 TE-Y-HDA-ST 20 M10 6.5 - 7.5 480 - 500

s s TE-C-HDA-B 22x125 TE-C-HDA-ST 22 M12 3.7 - 4.7 250 - 500


HDA-P 22-M12x125/30
s TE-Y-HDA-B 22x125 TE-Y-HDA-ST 22 M12 6.5 - 7.5 480 - 500
s s TE-C-HDA-B 22x155 TE-C-HDA-ST 22 M12 3.7 - 4.7 250 - 500
HDA-T 22-M12x125/30
s TE-Y-HDA-B 22x155 TE-Y-HDA-ST 22 M12 6.5 - 7.5 480 - 500
s s TE-C-HDA-B 22x125 TE-C-HDA-ST 22 M12 3.7 - 4.7 250 - 500
HDA-P 22-M12x125/50
s TE-Y-HDA-B 22x125 TE-Y-HDA-ST 22 M12 6.5 - 7.5 480 - 500
s s TE-C-HDA-B 22x175 TE-C-HDA-ST 22 M12 3.7 - 4.7 250 - 500
HDA-T 22-M12x125/50
s TE-Y-HDA-B 22x175 TE-Y-HDA-ST 22 M12 6.5 - 7.5 480 - 500

HDA-P 30-M16x190/40 s s TE-Y-HDA-B 30x190


HDA-T 30-M16x190/40 s s TE-Y-HDA-B 30x230
TE-Y-HDA-ST 30 M16 7.0 - 9.0 150 - 350
HDA-P 30-M16x190/60 s s TE-Y-HDA-B 30x190
HDA-T 30-M16x190/60 s s TE-Y-HDA-B 30x250

HDA-P 37-M20x250/50 s TE-Y-HDA-B 37x250


HDA-T 37-M20x250/50 s TE-Y-HDA-B 37x300
TE-Y-HDA-ST 37 M20 8.0 - 9.0 250
HDA-P 37-M20x250/100 s TE-Y-HDA-B 37x250
HDA-T 37-M20x250/100 s TE-Y-HDA-B 37x300

HDA-R stainless steel


Anchor Hilti Hammer Drill Stop drill bit Setting tool
TE 56/
TE 80 ATC-AVR Single impact
TE RPM under
TE 25
56-
TE 75 TE 70/TE 70-ATC energy for
(1st TE 35
TE 40-
TE 76/TE 76-ATC load (1/min)
AVR ATC setting
gear)
max impact energy

s s s TE-C-HDA-B 20x100 TE-C-HDA-ST 20 M10 3.7 - 4.7 250 - 500


HDA-PR 20-M10x100/20
s TE-Y-HDA-B 20x100 TE-Y-HDA-ST 20 M10 6.5 - 7.5 480 - 500
s s s TE-C-HDA-B 20x120 TE-C-HDA-ST 20 M10 3.7 - 4.7 250 - 500
HDA-TR 20-M10x100/20
s TE-Y-HDA-B 20x120 TE-Y-HDA-ST 20 M10 6.5 - 7.5 480 - 500

s s s TE-C-HDA-B 22x125 TE-C-HDA-ST 22 M12 3.7 - 4.7 250 - 500


HDA-PR 22-M12x125/30
s TE-Y-HDA-B 22x125 TE-Y-HDA-ST 22 M12 6.5 - 7.5 480 - 500
s s s TE-C-HDA-B 22x155 TE-C-HDA-ST 22 M12 3.7 - 4.7 250 - 500
HDA-TR 22-M12x125/30
s TE-Y-HDA-B 22x155 TE-Y-HDA-ST 22 M12 6.5 - 7.5 480 - 500
s s s TE-C-HDA-B 22x125 TE-C-HDA-ST 22 M12 3.7 - 4.7 250 - 500
HDA-PR 22-M12x125/50
s TE-Y-HDA-B 22x125 TE-Y-HDA-ST 22 M12 6.5 - 7.5 480 - 500
s s s TE-C-HDA-B 22x175 TE-C-HDA-ST 22 M12 3.7 - 4.7 250 - 500
HDA-TR 22-M12x125/50
s TE-Y-HDA-B 22x175 TE-Y-HDA-ST 22 M12 6.5 - 7.5 480 - 500

HDA-P 30-M16x190/40 s s TE-Y-HDA-B 30x190


HDA-T 30-M16x190/40 s s TE-Y-HDA-B 30x230
TE-Y-HDA-ST 30 M16 7.0 - 9.0 150 - 350
HDA-P 30-M16x190/60 s s TE-Y-HDA-B 30x190
HDA-T 30-M16x190/60 s s TE-Y-HDA-B 30x250

24 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HDA Undercut Anchor 1.0

HDA carbon steel - sheradized (heavy-duty galvanization)


Anchor Hilti Hammer Drill Stop drill bit Setting tool
TE 56/
TE 80 ATC-AVR Single impact
TE RPM under
TE 25
56-
TE 75 TE 70/TE 70-ATC energy for
(1st TE 35
TE 40-
TE 76/TE 76-ATC load (1/min)
AVR ATC setting
gear)
max impact energy

HDA-PF 20-M10x100/20 s TE-C-HDA-B 20x100


TE-C-HDA-ST 20 M10 3.5 - 4.0 610 - 630
HDA-TF 20-M10x100/20 s TE-C-HDA-B 20x120

HDA-PF 22-M12x125/30 s TE-C-HDA-B 22x125


HDA-TF 22-M12x125/30 s TE-C-HDA-B 22x155
TE-C-HDA-ST 22 M12 3.5 - 4.0 610 - 630
HDA-PF 22-M12x125/50 s TE-C-HDA-B 22x125
HDA-TF 22-M12x125/50 s TE-C-HDA-B 22x175

HDA-PF 30-M16x190/40 s s TE-Y-HDA-B 30x190


HDA-TF 30-M16x190/40 s s TE-Y-HDA-B 30x230
TE-Y-HDA-ST 30 M16 7.0 - 9.0 150 - 350
HDA-PF 30-M16x190/60 s s TE-Y-HDA-B 30x190
HDA-TF 30-M16x190/60 s s TE-Y-HDA-B 30x250

1.5 Ordering Information

HDA-T Anchor

HDA-T HDA-T F HDA-T R HDA HDA-T Anchor Stop Drill Bit Diamond Core Bit Setting Tool
Anchor (mm)
Item No. Item No. Item No. Box dia x min.emb/max. Description (mm)
Galvanized Sherardised 316 Stainless Qty thickness fastened Item No. dia. x drill depth Diameter Item No. Description
332090 TE-C-B20x120 331843 TE-C-ST-M10
331545 339361 339351 12 HDA-T M10x100/20 20mm (25/32”)
237450 TE-Y-B20x120 287133 TE-Y-ST-M10
332092 TE-C-B22x155 331844 TE-C-ST-M13
331548 339362 339352 8 HDA-T M12x125/30 22mm (7/8”)
237452 TE-Y-B22x155 287134 TE-Y-ST-M12
331549 339363 339353 8 HDA-T M12x125/50 332093 TE-C-B22x175 22mm (7/8”) 331844 TE-C-ST-M12
331552 339364 339354 4 HDA-T M16x190/40 332098 TE-Y-B30x230 30mm (1-1/8”) 331846 TE-Y-ST-M16
331553 339365 339355 4 HDA-T M16x190/60 332099 TE-Y-B30x250 30mm (1-1/8”) 331846 TE-Y-ST-M16
339267 – – 2 HDA-T M20x250/50 339271 TE-Y-B37x300 37mm (1-3/8”) 339269 TE-Y-ST-M20
339268 – – 2 HDA-T M20x250/100 339272 TE-Y-B37x350 37mm (1-3/8”) 339269 TE-Y-ST-M20

HDA-P Anchor

HDA-P HDA-P F HDA-P R HDA HDA-P Anchor Stop Drill Bit Diamond Core Bit Setting Tool
Anchor (mm)
Item No. Item No. Item No. Box dia x min.emb/max. Description (mm)
Galvanized Sherardised 316 Stainless Qty thickness fastened Item No. dia. x drill depth Diameter Item No. Description
332089 TE-C-B20x100 331843 TE-C-ST-M10
331544 339356 339346 12 HDA-P M10x100/20 20mm (25/32”)
237449 TE-Y-B20x100 287133 TE-Y-ST-M10
331091 TE-C-B22x125 331844 TE-C-ST-M13
331546 339357 339347 8 HDA-P M12x125/30 22mm (7/8”)
237451 TE-Y-B22x125 287134 TE-Y-ST-M13
331547 339358 339348 8 HDA-P M12x125/50 332091 TE-C-B22x125 22mm (7/8”) 331844 TE-C-ST-M12
331550 339359 339349 4 HDA-P M16x190/40 332097 TE-Y-B30x190 30mm (1-1/8”) 331846 TE-Y-ST-M16
331551 339360 339350 4 HDA-P M16x190/60 332097 TE-Y-B30x190 30mm (1-1/8”) 331846 TE-Y-ST-M16
339265 – – 2 HDA-P M20x250/50 339270 TE-Y-B37x250 37mm (1-3/8”) 339269 TE-Y-ST-M20
339266 – – 2 HDA-P M20x250/100 339270 TE-Y-B37x250 37mm (1-3/8”) 339269 TE-Y-ST-M20

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 25
Mechanical Anchoring Systems

1.0 HDA Undercut Anchor

1.6 HDA Removal

/…iʈÌˆÊ Ê,i“œÛ>Ê/œœÊˆÃÊ`iÈ}˜i`Ê̜ÊÀi“œÛiÊ̅iÊ Product Features


Hilti HDA Heavy Duty Mechanical Anchor when installed in UÊ
œ“«iÌiÊÀi“œÛ>ÊœvÊ Ê`iÈ}˜Ê>˜V…œÀÃÊvœÀÊÌi“«œÀ>ÀÞÊ
standard applications in accordance with Hilti guidelines. applications
UÊ /…iÊÀi“œÛ>Ê«ÀœViÃÃÊÃÌÀˆ«ÃÊ̅iÊ̅Ài>`ÃÊ̜ʫÀiÛi˜ÌÊÀiÕÃiÊ
of anchors for safety purposes
UÊ -ՈÌ>LiÊvœÀÊ>ÊÀœÌ>ÀÞʅ>““iÀÃÊ܈̅Ê/ ‡
ÊÃÌޏiÊV…ÕVŽÃ

Removal Instructions

TE-C

HDA-P HDA-T

1. Remove the nut and washer 2. Push back the grip (against 4. Insert the adapter (drive) into 5. Put adapter (drive) onto 8. To return the tool to its start-
from the threaded rod, (also this spring pressure). the drill chuck and lock the threaded spindle of the ing position, put the adapter
remove fastening part for 3. Allow the two drive lugs to (TE 25 recommended). removal tool and switch (drive) on the other end of
HDA-P applications). engage the groove in the Important: on the drill. the threaded spindle.
anchor sleeve using a slight sSwitch off the hammer- 6. The anchor sleeve will be 9. Switch on the hammer
twisting movement of the ing action (the removal extracted. drill until the adapter stop
grip. Release the grip. tool will be permanently 7. Disengage the drive lugs reaches the removal tool.
damaged if this step from the groove by lifting
is neglected.). up and twisting the grip.
sUse low speed
(setting 1 for the TE 25).

Removal Tool with Adapter

Applicable

Item No. Description Qty/Pkg Anchor Sizes

333433 TE-C-HDA-RT 20-M10 1 HDA M10


333434 TE-C-HDA-RT 22-M12 1 HDA M12
333435 TE-C-HDA-RT 30-M16 1 HDA M16
339273 TE-C-HDA-RT 37-M20 1 HDA M20

26 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HSL-3 Heavy Duty Sleeve Anchor 2.0

2.1 HSL-3 Product Description Ó°£Ê *Àœ`ÕVÌÊ iÃVÀˆ«Ìˆœ˜

2.2 Material Specifications

2.3 Technical Data

HSL-3 Heavy Duty Anchor HSL-3-B Heavy Duty Anchor 2.4 Installation Instructions
with Torque Cap
2.5 Ordering Information
Red Setting Indicator
/…ÀiiÊ>VVÕÀ>ÌiÞÊÈâi`Ê
-‡Î‡Êi>ÛÞÊ ÕÌÞʘV…œÀÊ shear pins are provided in
܈̅Ê/…Ài>`i`Ê,œ` the red indicator cap. As
the required installation
Maximum fastened torque (Tinst) is reached the
Metric ̅ˆVŽ˜iÃÃÊ­““® red indicator cap shears off. A green seal on
the bolt head appears which indicates that
HSL-3-G M 12/25 the anchor has been set properly.
Heavy duty L>˜Ž‡LœÌ Metric thread Example: HSL-3-G M12/25 Bolt
Sleeve ÊÃÌÕ` ÈâiÊ­““®ÆʘœÌÊ /…ˆÃʈÃÊ>˜Ê-‡ÎÊÃÌÕ`Ê>˜V…œÀ°Ê/…iÊ̅Ài>`ÊÈâiÊ
(Expansion) B torque cap hole diameter is 12 mm and this anchor can attach up to a Washer
Anchor Óxʓ“Ê̅ˆVŽÊ«>Ìi

The Hilti HSL-3 Heavy Duty Sleeve UÊ -ՈÌ>LiÊvœÀÊ`ޘ>“ˆVʏœ>`ˆ˜}]Ê


including seismic, fatigue Minimum
Anchor is a torque-controlled expansion
>˜`ÊŜVŽ Embedment
bolt designed for high performance in >ÀŽ
static and dynamic application including UÊ œÊ눘˜ˆ˜}ʜvÊ̅iÊ>˜V…œÀʈ˜Ê…œiÊ
when tightening bolt or nut Spacer
̅iÊÌi˜Ãˆœ˜Ê✘iʜvÊVœ˜VÀiÌiÊÃÌÀÕVÌÕÀiÃÊ
Sleeve
܅iÀiÊVÀ>VŽˆ˜}ÊV>˜ÊLiÊiÝ«iVÌi`°ÊÊ-‡ Guide Specifications
ÎÊ>˜V…œÀÃÊ>ÀiÊ>Û>ˆ>Liʈ˜Ê“iÌÀˆVÊÈâiÃÊ Ý«>˜Ãˆœ˜Ê˜V…œÀÃ\Ê
>ÀLœ˜ÊÃÌiiÊ *>Ã̈VÊ
from M8 to M24. With a variety of head anchor consists of hex head bolt collaps-
configurations, including bolt, stud and ible sec-
(threaded stud), sleeve, expansion
torque cap. All versions are available in tion with
sleeve, expansion cone, collapsible anchor
∘V‡«>Ìi`ÊV>ÀLœ˜ÊÃÌii° plastic sleeve, (nut) and washer. rotation
Anchors shall be torque controlled prevention
Product Features
expansion bolt as manufactured
UÊ ««ÀœÛi`ÊvœÀÊÕÃiʈ˜Ê̅iÊVœ˜VÀiÌiÊ
Ìi˜Ãˆœ˜Ê✘iÊ­VÀ>VŽi`ÊVœ˜VÀiÌi® by Hilti.

UÊ ˆ}…ʏœ>`ÊV>«>VˆÌÞ
Expansion
UÊ œÀVi‡Vœ˜ÌÀœi`ÊiÝ«>˜Ãˆœ˜Ê܅ˆV…Ê Sleeve
allows for follow-up expansion
UÊ ,iˆ>LiÊV>“«ˆ˜}ʜvÊ«>ÀÌÊv>ÃÌi˜i`Ê Cone
to overcome gaps

2.2 Material Specifications

>ÀLœ˜Ê-ÌiiÊ œÌʜÀÊ/…Ài>`i`Ê,œ`ÊvœÀÊ-‡ÎÊ­ œÌ®]Ê-‡ÎÊ­-ÌÕ`®Ê>˜`Ê-‡Î‡ Ê


Vœ˜vœÀ“ÊÌœÊ  Ê Ê-"Ên™n‡£]ÊÀ>`iÊn°n]ÊvyʀʙÎʎÈ]Êvuʀʣ£ÈʎÈ

>ÀLœ˜Ê-ÌiiÊ ÕÌÊVœ˜vœÀ“ÃÊÌœÊ  ʙÎ{]ÊÀ>`iÊn]Êvuʀʣ£ÈʎÈ

>ÀLœ˜Ê-ÌiiÊ7>ÅiÀÊVœ˜vœÀ“ÃÊÌœÊ  Ê£x{{]ÊÀ>`iÊ-ÌÎÇ]ÊvuʀʣääʎÈ
Carbon Steel Expansion Cone conforms to DIN 1654-4, fuʀÊnäʎÈ
Carbon Steel Expansion Sleeve (M8-M16) conforms to DIN 10139 and (M20-M24)
conforms to DIN 2393-2
Carbon Steel Spacing Sleeve conforms to DIN 2393 T1, fuʀʣääʎÈ

œ>«ÃˆLiÊ-iiÛiʈÃʓ>`iÊvÀœ“Ê>ViÌ>Ê«œÞœÝޓi̅ޏi˜iÊ­*"®ÊÀiȘ

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 27
Mechanical Anchoring Systems

2.0 HSL-3 Heavy Duty Sleeve Anchor

2.3 Technical Data


Table 1 — HSL-3 Specifications
HSL-3 Anchor Thread Diameter (mm)
Details
M8 M10 M12 M16 M20 M24
nominal drill bit diameter1 d bit mm 12 15 18 24 28 32
Hilti matched-tolerance TE-CX 12/22 TE-CX 15/27 TE-C 18/22 TE-C-T 24/27 TE-C-T 28/27 TE-YX 32/37
– –
carbide-tipped drill bit TE-YX 12/35 TE-YX 15/35 TE-YX 18/32 TE-YX 24/32 TE-YX 28/32
minimum base material thickness
h mm 110 (120) 120 (140) 135 (160) 160 (200) 190 (250) 225 (300)
(to obtain smallest critical edge distance)
minimum hole depth ho mm 80 90 105 125 155 180
effective embedment depth h ef,min mm 60 70 80 100 125 150
minimum clearance hole diameter
dh mm 14 17 20 26 31 35
in part being fastened
max. cumulative gap between part(s)
– mm 4 5 8 9 12 16
being fastened and concrete surface
maximum thickness of part fastened
t mm 20 40 20 40 25 50 25 50 30 60 30 60
HSL-3, HSL-3-B
overall length of anchor
– mm 98 118 110 130 131 156 153 178 183 213 205 235
HSL-3, HSL-3-B
maximum thickness of part fastened
t mm 20 20 25 50 25 50 30 60
HSL-3-G
overall length of anchor
– mm 102 115 139 164 163 188 190 220
HSL-3-G
washer diameter dw mm 20 25 30 40 45 50
installation torque HSL-3 Tinst Nm 25 50 80 120 200 250

installation torque HSL-3-G Tinst Nm 20 35 60 80 160


wrench size HSL-3, HSL-3-G – mm 13 17 19 24 30 36
wrench size HSL-3-B – mm 24 30 36 41
1 Use metric bits only.

dw

dh t


h nom
ho
h

d bit

28 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HSL-3 Heavy Duty Sleeve Anchor 2.0


Table 2 — Design Information for use with CSA A23.3-04, Annex D
Nominal anchor diameter Ref.
Design parameter Symbol Units
M8 M10 M12 M16 M20 M24 A23.3-04
Anchor O.D. do mm 12 15 18 24 28 32
Effective min. embedment depth hef,min mm 60 70 80 100 125 150
Anchor category 1, 2 or 3 1 1 1 1 1 1 D.5.4c
Concrete material resistance factor for concrete Fc 0.65 0.65 0.65 0.65 0.65 0.65 8.4.2
Steel embedment material resistance factor for reinforcement Fs 0.85 0.85 0.85 0.85 0.85 0.85 8.4.3
-ÌÀi˜}̅ÊÀi`ÕV̈œ˜Êv>V̜ÀÊvœÀÊÌi˜Ãˆœ˜]ÊÃÌiiÊv>ˆÕÀiʓœ`iÃÊÊ ,ÊÊ Ê ä°näÊÊ ä°näÊÊ ä°näÊÊ ä°näÊÊ ä°näÊÊ ä°näÊÊ °x°{>
-ÌÀi˜}̅ÊÀi`ÕV̈œ˜Êv>V̜ÀÊvœÀÊÅi>À]ÊÃÌiiÊv>ˆÕÀiʓœ`iÃÊ Ê,ÊÊ Ê ä°ÇxÊÊ ä°ÇxÊÊ ä°ÇxÊÊ ä°ÇxÊÊ ä°ÇxÊÊ ä°ÇxÊÊ °x°{>
Ê ,ÊÊ
œ˜`°ÊÊÊ £°£xÊÊ £°£xÊÊ £°£xÊÊ £°£xÊÊ £°£xÊÊ £°£xÊÊ °x°{V
Strength reduction factor for tension, concrete failure modes
Ê ,ÊÊ
œ˜`°Ê ÊÊ £°ääÊÊ £°ääÊÊ £°ääÊÊ £°ääÊÊ £°ääÊÊ £°ääÊÊ °x°{V
Ê ,ÊÊ
œ˜`°ÊÊÊ £°£xÊÊ £°£xÊÊ £°£xÊÊ £°£xÊÊ £°£xÊÊ £°£xÊÊ °x°{V
Strength reduction factor for shear, concrete failure modes
Ê ,ÊÊ
œ˜`°Ê ÊÊ £°ääÊÊ £°ääÊÊ £°ääÊÊ £°ääÊÊ £°ääÊÊ £°ääÊÊ °x°{V
Yield strength of anchor steel fyÊÊ *>ÊÊ È{äÊÊ È{äÊÊ È{äÊÊ È{äÊÊ È{äÊÊ È{ä
Ultimate strength of anchor steel futÊÊ *>ÊÊ nääÊÊ nääÊÊ nääÊÊ nääÊÊ nääÊÊ nää
Effective cross-sectional area of anchor Ase mm2 36.8 58.1 84.5 156.8 245.2 352.9 D.6.1.2
>V̜Ài`Ê-ÌiiÊ,iÈÃÌ>˜Viʈ˜ÊÌi˜Ãˆœ˜ÊÊ NsrÊÊ Ž ÊÊ Óä°äÊÊ Î£°ÈÊÊ {È°äÊÊ nx°ÎÊÊ £ÎΰÎÊÊ £™£°™ÊÊ °È°£°Ó

œivvˆVˆi˜ÌÊvœÀÊv>V̜Ài`ÊVœ˜VÀiÌiÊLÀi>ŽœÕÌÊÀiÈÃÌ>˜Viʈ˜ÊÌi˜Ãˆœ˜ÊÊ ŽÊÊ Ê ÇÊÊ £äÊÊ £äÊÊ £äÊÊ £äÊÊ £äÊÊ °È°Ó°È
Modification factor for resistance in tension to account
#c,N 1.40 1.00 1.00 1.00 1.00 1.00 D.6.2.6
ÊvœÀÊ՘VÀ>VŽi`ÊVœ˜VÀiÌi
>V̜Ài`ʫՏœÕÌÊÀiÈÃÌ>˜Viʈ˜ÊÓäÊ*>Ê՘VÀ>VŽi`ÊVœ˜VÀiÌiÊÊ Np,uncrÊÊ Ž ÊÊ £Î°£ÊÊ ÉÊÊ ÉÊÊ ÉÊÊ ÉÊÊ ÉÊÊ ÊȰΰÓ
>V̜Ài`ʫՏœÕÌÊÀiÈÃÌ>˜Viʈ˜ÊÓäÊ*>ÊVÀ>VŽi`ÊVœ˜VÀiÌiÊ NprÊÊ Ž ÊÊ n°ÇÊÊ £{°äÊÊ ÉÊÊ ÉÊÊ ÉÊÊ ÉÊÊ °È°Î°Ó
>V̜Ài`Ê-ÌiiÊ,iÈÃÌ>˜Viʈ˜ÊÅi>ÀÊ-‡Î]ʇ ÊÊ VsrÊÊ Ž ÊÊ Óä°xÊÊ Ó™°äÊÊ {£°nÊÊ Çx°ÇÊÊ ££Ó°£ÊÊ £Îä°ÎÊÊ °Ç°£°ÓV
>V̜Ài`Ê-ÌiiÊ,iÈÃÌ>˜Viʈ˜ÊÅi>ÀÊ-‡Î‡ÊÊ VsrÊÊ Ž ÊÊ £Ç°ÓÊÊ ÓΰnÊÊ Î{°xÊÊ È{°ÎÊÊ ™{°äÊÊ ÉÊÊ °Ç°£°ÓV
>V̜Ài`ʫՏœÕÌÊÀiÈÃÌ>˜Viʈ˜ÊÓäÊ*>Ê
œ˜VÀiÌi]ÊÃiˆÃ“ˆVÊÊ Npr,seismicÊÊ Ž ÊÊ ÉÊÊ ÉÊÊ ÉÊÊ ÉÊÊ ÉÊÊ Îΰ{
>V̜Ài`Ê-ÌiiÊ,iÈÃÌ>˜Viʈ˜ÊÅi>À]ÊÃiˆÃ“ˆVÊ-‡Î]ʇ ]ʇ-]ʇ-ÊÊ Vsr,seismic Ê Ž ÊÊ £Î°£Ê Ó{°äÊ ÎΰÇÊ Çä°ÎÊ nÓ°ÈÊ £än°Ó
>V̜Ài`Ê-ÌiiÊ,iÈÃÌ>˜Viʈ˜ÊÅi>À]ÊÃiˆÃ“ˆVÊ-‡Î‡ÊÊ Vsr,seismicÊÊ Ž ÊÊ £ä°ÇÊÊ £™°ÈÊÊ ÓÇ°™ÊÊ x™°ÇÊÊ È™°{ÊÊ É
݈>ÊÃ̈vv˜iÃÃʈ˜ÊÃiÀۈViʏœ>`ÊÀ>˜}i]Ê՘VÀ>VŽi`ÊVœ˜VÀiÌiÊÊ B uncrÊÊ Ž ɓ“ÊÊ xÓ°xÊÊ xÓ°xÊÊ xÓ°xÊÊ xÓ°xÊÊ xÓ°xÊ xÓ°x
݈>ÊÃ̈vv˜iÃÃʈ˜ÊÃiÀۈViʏœ>`ÊÀ>˜}i]ÊVÀ>VŽi`ÊVœ˜VÀiÌiÊÊ B crÊÊ Ž ɓ“ÊÊ x°ÎÊÊ £Ó°ÎÊÊ ÓÓ°nÊÊ ÓÓ°nÊÊ ÓÓ°nÊÊ ÓÓ°n

Nominal anchor diameter


Edge Distance, Spacing and Member Thickness Requirements Symbol Units
M8 M10 M12 M16 M20 M24
ˆ˜ˆ“Õ“ÊVœ˜VÀiÌiÊ̅ˆVŽ˜iÃÃÊ hmin mm 120 140 160 200 250 300
Critical edge distance cac mm 110 110 120 150 225 225
Minimum edge distance cmin mm 60 70 90 120 125 150
Minimum anchor spacing smin mm 60 70 80 100 125 150
Combination of edge distance and spacing
Ê œÀÊn\ÊÊ sdesign ≥ mm greater of [332 - (3.20 x cdesign)] mm or smin
Ê œÀÊ£ä\ÊÊ sdesign ≥ mm greater of [456 - (3.09 x cdesign)] mm or smin
Ê œÀÊ£Ó\ÊÊ sdesign ≥ mm greater of [557 - (3.08 x cdesign)] mm or smin
Ê œÀÊ£È\ÊÊ sdesign ≥ mm greater of [650 - (2.75 x cdesign)] mm or smin
Ê œÀÊÓä\ÊÊ sdesign ≥ mm greater of [681 - (2.65 x cdesign)] mm or smin
Ê œÀÊÓ{\ÊÊ sdesign ≥ mm greater of [675 - (2.50 x cdesign)] mm or smin

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 29
Mechanical Anchoring Systems

2.0 HSL-3 Heavy Duty Sleeve Anchor

HSL-3 Heavy Duty Sleeve Anchor Sample Calculations

Given: AN
(2) HSL-3 M10 anchors under static tension load as shown. t
1.5h ef
h e f = 70 mm
Slab on grade, f ' cÊrÊÓäÊ*>°
No supplementary reinforcing.
ÃÃՓiÊ՘VÀ>VŽi`ÊVœ˜VÀiÌi° h ef
Condition B per CSA A23.3 D.5.4 c h s = 150 mm
Calculate the factored tensile resistance for this configuration.

1.5h ef
1.5h ef c = 100 mm

Calculation per CSA A23.3 Annex D and this report. Code Ref.
Step 1. Calculate factored steel resistance of anchor in tension
N sr = nA se F s f u t ,ÊrÊÓÊÝÊxn°£ÊÝÊä°nxÊÝÊnääÊÝÊä°nÊrÊÈΰÓʎ Ê °È°£°Ó
-Ìi«ÊÓ°Ê
>VՏ>ÌiÊv>V̜Ài`ÊVœ˜VÀiÌiÊLÀi>ŽœÕÌÊÃÌÀi˜}̅ʜvÊ>˜V…œÀʈ˜ÊÌi˜Ãˆœ˜Ê
N cbgr = (ANÉNo) #ec,N #ed,N #c,N #cp,N Nbr D.6.2.1
-Ìi«ÊΰÊ6iÀˆvÞʓˆ˜ˆ“Õ“ÊVœ˜VÀiÌiÊ̅ˆVŽ˜iÃÃ]ʓˆ˜ˆ“Õ“Êë>Vˆ˜}Ê>˜`Êi`}iÊ`ˆÃÌ>˜Vi\
hminÊrÊ£{äʓ“ʐʣxäʓ“ÆʜŽ
sminÊrÊÇäʓ“ʐʣxäʓ“ÆʜŽ
cminÊrÊÇäʓ“ʐʣääʓ“ÆʜŽ
sdesign > 456 – (3.09 x c design) or s minÆʜŽÊȘViÊà design = 150 mm ≥ 147 mm or 70 mm D.9
Step 3a. Calculate ANo and ANÊvœÀÊ̅iÊ>˜V…œÀ>}i\Ê
ANO = 9 h e f 2 = 9 x (70)2 = 44,100 mm2
AN = (1.5h e f + c)(3h e f + s) = [1.5 x (70) + 100][3 x (70) + 150] = 73,800 mm2 < 2 ANOÆʜŽÊ °È°Ó°£
Step 3b. Calculate modification factor for eccentrically loaded anchors groups #ec,N' = 1; no eccentricity D.6.2.4
Step 3c. Calculate N br \
N b r = k F c (f' c ) 0. 5 h e f 1. 5 R = 10 x 0.65 x 200.5 x 701.5ÊÝÊ£°ääÊrʣǰäÓʎ Ê °È°Ó°Ó
-Ìi«ÊÎ`°Ê
>VՏ>Ìiʓœ`ˆwV>̈œ˜Êv>V̜ÀÊvœÀÊi`}iÊivviVÌÃ\Ê#ed,N = 0.7 + 0.3(c m i n ÉÊ£°xh e f ) = 0.986 D.6.2.5
Step 3e. #c,N = 1.0 D.6.2.6
-Ìi«ÊÎv°Ê
>VՏ>Ìiʓœ`ˆwV>̈œ˜Êv>V̜ÀÊvœÀÊ돈Ì̈˜}\Ê
#cp,N = max [c a ,m i n ÊÉÊV ac ; 1.5h ef ÊÉÊV ac RÊrʓ>ÝÊQ£ääÉ££äÊÆÊ£°xÊ­Çä®ÊÉÊ££äRÊrÊ䰙xxÊ °È°Ó°Ç
Step 3g. Calculate N cbg r\ÊÊN cbg r ÊrÊ­ÇÎnääÊÉÊ{{£ää®ÊÝÊ£ÊÝÊ䰙nÈÊÝÊ£ÊÝÊ䰙xxÊÝʣǰäÓÊrÊÓÈ°nʎ Ê °È°Ó°£
-Ìi«Ê{°Ê
…iVŽÊv>V̜Ài`ʫՏœÕÌÊÀiÈÃÌ>˜Vi\ÊÃiiÊ-‡ÎÊ iÈ}˜Ê˜vœÀ“>̈œ˜Ê/>Li]ÊN p ,unc r does not govern. D.6.3.1
-Ìi«Êx°Ê
œ˜ÌÀœˆ˜}Êv>V̜Ài`ÊÌi˜ÃˆiÊÀiÈÃÌ>˜Vi\ÊN cbg r ÊrÊÓÈ°nʎ Ê ‡

30 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HSL-3 Heavy Duty Sleeve Anchor 2.0


Notes for Tension Tables Notes for Shear Tables

£ÊœÀʜ̅iÀÊVœ˜VÀiÌiÊÃÌÀi˜}̅Ã]ʓՏ̈«ÞÊNcbr and Npr by 1 Design strengths in table are for anchors near one edge
corresponding influence of concrete strength factor, fb. only. The values do not apply where the distance to an
edge, measured perpendicular to c1, is less than 1.5c1.
2 The ultimate strength of the anchor steel, futÊrÊnääÊ*>°
Shear force is assumed to act perpendicular, towards the
3 Design strengths in the table are based on resistance edge with no eccentricity.
“œ`ˆvˆV>̈œ˜Êv>V̜ÀÊ,]ʜvÊ-iV̈œ˜Ê °x°{°Ê>V̜Ài`ÊÌi˜ÃˆiÊ
ÓÊœÀʜ̅iÀÊVœ˜VÀiÌiÊÃÌÀi˜}̅Ã]ʓՏ̈«ÞÊVcbr by corresponding
load Nf must be computed from the load combinations
influence of concrete strength factor, fb.
referenced in Clause 8.3.2. Design strengths for concrete
LÀi>ŽœÕÌ]ÊNbr, pullout, Npr, and sideface blowout, Nsbr 3 The ultimate strength of the anchor steel, futÊrÊnääÊ*>°
are based on Condition B. Where supplementary
4 Design strengths in the table are based on resistance
reinforcement is provided to satisfy Condition A, design
“œ`ˆvˆV>̈œ˜Êv>V̜ÀÊ,]ʜvÊ-iV̈œ˜Ê °x°{°Ê>V̜Ài`ÊÅi>ÀÊ
strengths for Nbr and Nsbr may be increased by the ratio
load Vf must be computed from the load combinations
œvÊ, condition A ÊÉÊ, condition B . This increase does not apply to
referenced in Clause 8.3.2. Design strengths for
pullout strength, Npr.
Vœ˜VÀiÌiÊLÀi>ŽœÕÌ]ÊVbr, are based on Condition B. Where
{Ê7…iÀiÊ>˜>ÞÈÃʈ˜`ˆV>ÌiÃÊ̅>ÌÊ̅iÀiÊ܈ÊLiʘœÊVÀ>VŽˆ˜}Ê>ÌÊ supplementary reinforcement is provided to satisfy
service load levels (ft < fr) in the region of the anchor, the Condition A, this design may be increased by the ratio of
`iÈ}˜ÊÃÌÀi˜}̅ÃÊvœÀÊVœ˜VÀiÌiÊLÀi>ŽœÕÌʈ˜ÊÌi˜Ãˆœ˜]ÊNbr, may ,condition AÊÉÊ,condition B. This increase does not apply to pryout
be increased by #c,N (#c,N = 1.4 for M8 and 1.0 for all other capacities, for which condition B is always assumed.
Èâiî°Ê-iiÊ-iV̈œ˜Ê °È°Ó°È°
xÊ7…iÀiÊ>˜>ÞÈÃʈ˜`ˆV>ÌiÃÊ̅>ÌÊ̅iÀiÊ܈ÊLiʘœÊVÀ>VŽˆ˜}Ê>ÌÊ
xÊ7…iÀiÊ>˜>ÞÈÃʈ˜`ˆV>ÌiÃÊ̅>ÌÊ̅iÀiÊ܈ÊLiʘœÊVÀ>VŽˆ˜}Ê>ÌÊ service load levels (ft < fr) in the region of the anchor, the
service load levels (ft < fr) in the region of the anchor, the `iÈ}˜ÊÃÌÀi˜}̅ÃÊvœÀÊVœ˜VÀiÌiÊLÀi>ŽœÕÌʈ˜ÊÅi>À]ÊVbr, may
design strengths for concrete pullout in tension, Npr, may be be increased by 40%. See Section D.7.2.7.
increased by 40%. See Section D.6.3.6.
ÈÊ/…iÊ`iÈ}˜ÊÃÌÀi˜}̅ÃÊvœÀÊVœ˜VÀiÌiÊLÀi>ŽœÕÌ]ÊVbr, are based
6 Stainless steel HSL anchors are not applicable to the on the shear load being applied perpendicular towards

-ÊÓΰ·ä{ʘ˜iÝÊ Ê`iÈ}˜Ê“i̅œ`°ÊÊœÀÊ>««ˆV>̈œ˜ÃÊ the edge. If the load is applied parallel to the edge, the
ÀiµÕˆÀˆ˜}ÊÃÌ>ˆ˜iÃÃÊÃÌiiÊ>˜V…œÀÃ]ÊVœ˜Ãˆ`iÀÊ ‡*,]Ê ‡ strengths may be increased 100%. See Section D.7.2.1c.
/,ʜÀÊ ‡,/<ʈ˜Ê̅ˆÃÊÃÕ««i“i˜Ì°
7 Linear interpolation for intermediate values of edge
distance, c1 is permissible.

8 Stainless steel HSL anchors are not applicable to the



-ÊÓΰ·ä{ʘ˜iÝÊ Ê`iÈ}˜Ê“i̅œ`°ÊÊœÀÊ>««ˆV>̈œ˜ÃÊ
ÀiµÕˆÀˆ˜}ÊÃÌ>ˆ˜iÃÃÊÃÌiiÊ>˜V…œÀÃ]ÊVœ˜Ãˆ`iÀÊ ‡*,]ÊÊ
 ‡/,ʜÀÊ ‡,/<ʈ˜Ê̅ˆÃÊÃÕ««i“i˜Ì°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 31
Mechanical Anchoring Systems

2.0 HSL-3 Heavy Duty Sleeve Anchor


Table 1 - Factored resistance for Single HSL-3, -G, -B anchor subject to Tensile Loads in Cracked Concrete (f ' c = 20 MPa)

Minimum
Min. Nsr - Tension
Embedment Edge 1,3,4 Npr - Nsbr - Sideface
Size Concrete Strength of Ncbr - Tension Breakout (kN)
Depth, hef Distance Pullout1,5 Blowout
Thickness, h
cmin Anchor2

mm mm mm kN c1 - edge distance (mm) kN kN


cmin 100 150 200 250 300 350 400 450

M8 60 120 60 20.0 7.1 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 8.7 N/A
M10 70 140 70 31.6 12.8 16.4 17.0 17.0 17.0 17.0 17.0 17.0 17.0 1 4.0 N/A
M12 80 160 90 46.0 16.8 18.1 20.8 20.8 20.8 20.8 20.8 20.8 20.8 N/A N/A
M16 100 200 120 85.3 24.6 X 29.1 29.1 29.1 29.1 29.1 29.1 29.1 N/ A N/A
M20 125 250 125 133.3 30.5 X 34.4 40.6 40.6 40.6 40.6 40.6 40.6 N /A N/A
M24 150 300 150 191.9 40.1 X 40.1 48.8 53.4 53.4 53.4 53.4 53.4 N /A N/A

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22
35 1.32
40 1.41
45 1.50
50 1.58 c1
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°

32 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HSL-3 Heavy Duty Sleeve Anchor 2.0


Table 2 - Factored resistance for 2 HSL-3, -G, -B anchors subject to Tensile Loads
in Cracked Concrete (f'c = 20 MPa)
Nsr - Tension
Spacing, 1,3,4 Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Ncbgr - Tension Breakout of Group (kN)
s Group1,5 of Group
Anchor Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
60 100 150 200 250 300 350 400 450
100 X 14.7 14.7 14.7 14.7 14.7 14.7 14.7 14.7
150 13.0 17.3 17.3 17.3 17.3 17.3 17.3 17.3 17.3
200 14.2 18.9 18.9 18.9 18.9 18.9 18.9 18.9 18.9
250 14.2 18.9 18.9 18.9 18.9 18.9 18.9 18.9 18.9
M8 60 120 40.0 300 14.2 18.9 18.9 18.9 18.9 18.9 18.9 18.9 18.9 17.5 N/A
350 14.2 18.9 18.9 18.9 18.9 18.9 18.9 18.9 18.9
400 14.2 18.9 18.9 18.9 18.9 18.9 18.9 18.9 18.9
450 14.2 18.9 18.9 18.9 18.9 18.9 18.9 18.9 18.9
500 14.2 18.9 18.9 18.9 18.9 18.9 18.9 18.9 18.9
cmin
70 100 150 200 250 300 350 400 450
100 X X 25.1 25.1 25.1 25.1 25.1 25.1 25.1
150 X 28.1 29.2 29.2 29.2 29.2 29.2 29.2 29.2
200 X 32.0 33.2 33.2 33.2 33.2 33.2 33.2 33.2
250 25.5 32.8 34.0 34.0 34.0 34.0 34.0 34.0 34.0
M10 70 140 63.2 300 25.5 32.8 34.0 34.0 34.0 34.0 34.0 34.0 34.0 27.9 N/A
350 25.5 32.8 34.0 34.0 34.0 34.0 34.0 34.0 34.0
400 25.5 32.8 34.0 34.0 34.0 34.0 34.0 34.0 34.0
450 25.5 32.8 34.0 34.0 34.0 34.0 34.0 34.0 34.0
500 25.5 32.8 34.0 34.0 34.0 34.0 34.0 34.0 34.0
cmin
90 100 150 200 250 300 350 400 450
100 X X 29.5 29.5 29.5 29.5 29.5 29.5 29.5
150 X X 33.8 33.8 33.8 33.8 33.8 33.8 33.8
200 X X 38.1 38.1 38.1 38.1 38.1 38.1 38.1
250 X 36.2 41.6 41.6 41.6 41.6 41.6 41.6 41.6
M12 80 160 92.0 300 33.7 36.2 41.6 41.6 41.6 41.6 41.6 41.6 41.6 N/A N/A
350 33.7 36.2 41.6 41.6 41.6 41.6 41.6 41.6 41.6
400 33.7 36.2 41.6 41.6 41.6 41.6 41.6 41.6 41.6
450 33.7 36.2 41.6 41.6 41.6 41.6 41.6 41.6 41.6
500 33.7 36.2 41.6 41.6 41.6 41.6 41.6 41.6 41.6
cmin
120 150 200 250 300 350 400 450
100 X X 38.8 38.8 38.8 38.8 38.8 38.8
150 X X 43.6 43.6 43.6 43.6 43.6 43.6
200 X X 48.4 48.4 48.4 48.4 48.4 48.4
250 X 53.3 53.3 53.3 53.3 53.3 53.3 53.3
M16 100 200 170.6 300 X 58.1 58.1 58.1 58.1 58.1 58.1 58.1 N/A N/A
350 49.2 58.1 58.1 58.1 58.1 58.1 58.1 58.1
400 49.2 58.1 58.1 58.1 58.1 58.1 58.1 58.1
450 49.2 58.1 58.1 58.1 58.1 58.1 58.1 58.1
500 49.2 58.1 58.1 58.1 58.1 58.1 58.1 58.1
cmin
125 150 200 250 300 350 400 450
100 X X X X X X X X
150 X X X 56.9 56.9 56.9 56.9 56.9
200 X X 62.3 62.3 62.3 62.3 62.3 62.3
250 X X 67.7 67.7 67.7 67.7 67.7 67.7
M20 125 250 266.6 300 X 61.9 73.1 73.1 73.1 73.1 73.1 73.1 N/A N/A
350 58.9 66.4 78.5 78.5 78.5 78.5 78.5 78.5
400 60.9 68.7 81.3 81.3 81.3 81.3 81.3 81.3
450 60.9 68.7 81.3 81.3 81.3 81.3 81.3 81.3
500 60.9 68.7 81.3 81.3 81.3 81.3 81.3 81.3
cmin
150 200 250 300 350 400 450
100 X X X X X X X
150 X X 71.2 71.2 71.2 71.2 71.2
200 X 70.4 77.1 77.1 77.1 77.1 77.1
250 X 75.8 83.1 83.1 83.1 83.1 83.1
M24 150 300 383.8 300 66.8 81.3 89.0 89.0 89.0 89.0 89.0 N/A N/A
350 71.2 86.7 94.9 94.9 94.9 94.9 94.9
400 75.7 92.1 100.9 100.9 100.9 100.9 100.9
450 80.1 97.5 106.8 106.8 106.8 106.8 106.8
500 80.1 97.5 106.8 106.8 106.8 106.8 106.8
Notes:
A. For eccentric loading, multiply Ncbr by the modification factor for eccentrically loaded anchor groups,  ec,N as per Section D.6.2.4.
B. If anchors are affected by more than one edge distance use formulas to calculate Concrete Resistance

Influence of Concrete Strength, fb


f 'c (MPa) fb
20 1.00
25 1.12
s
30 1.22
35 1.32
40 1.41
45 1.50
50 1.58 c1
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 33
Mechanical Anchoring Systems

2.0 HSL-3 Heavy Duty Sleeve Anchor


Table 3 - Factored resistance for 4 equally spaced HSL-3, -G, -B anchors subject to Tensile Loads
in Cracked Concrete (f'c = 20 MPa)
Nsr - Tension
Spacing, Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Ncbgr - Tension Breakout of Group1,3,4 (kN)
s Group1,5 of Group
Anchor Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
60 100 150 200 250 300 350 400 450
100 X 22.9 22.9 22.9 22.9 22.9 22.9 22.9 22.9
150 26.0 31.8 31.8 31.8 31.8 31.8 31.8 31.8 31.8
200 31.2 37.8 37.8 37.8 37.8 37.8 37.8 37.8 37.8
250 31.2 37.8 37.8 37.8 37.8 37.8 37.8 37.8 37.8
M8 60 120 80.0 300 31.2 37.8 37.8 37.8 37.8 37.8 37.8 37.8 37.8 34.9 N/A
350 31.2 37.8 37.8 37.8 37.8 37.8 37.8 37.8 37.8
400 31.2 37.8 37.8 37.8 37.8 37.8 37.8 37.8 37.8
450 31.2 37.8 37.8 37.8 37.8 37.8 37.8 37.8 37.8
500 31.2 37.8 37.8 37.8 37.8 37.8 37.8 37.8 37.8
cmin
70 100 150 200 250 300 350 400 450
100 X X 37.1 37.1 37.1 37.1 37.1 37.1 37.1
150 X 48.6 50.0 50.0 50.0 50.0 50.0 50.0 50.0
200 X 63.2 64.9 64.9 64.9 64.9 64.9 64.9 64.9
250 56.2 66.3 68.1 68.1 68.1 68.1 68.1 68.1 68.1
M10 70 140 126.4 300 56.2 66.3 68.1 68.1 68.1 68.1 68.1 68.1 68.1 55.9 N/A
350 56.2 66.3 68.1 68.1 68.1 68.1 68.1 68.1 68.1
400 56.2 66.3 68.1 68.1 68.1 68.1 68.1 68.1 68.1
450 56.2 66.3 68.1 68.1 68.1 68.1 68.1 68.1 68.1
500 56.2 66.3 68.1 68.1 68.1 68.1 68.1 68.1 68.1
cmin
90 100 150 200 250 300 350 400 450
100 X X 41.7 41.7 41.7 41.7 41.7 41.7 41.7
150 X X 54.9 54.9 54.9 54.9 54.9 54.9 54.9
200 X X 69.9 69.9 69.9 69.9 69.9 69.9 69.9
250 X 75.7 83.2 83.2 83.2 83.2 83.2 83.2 83.2
M12 80 160 184.0 300 72.2 75.7 83.2 83.2 83.2 83.2 83.2 83.2 83.2 N/A N/A
350 72.2 75.7 83.2 83.2 83.2 83.2 83.2 83.2 83.2
400 72.2 75.7 83.2 83.2 83.2 83.2 83.2 83.2 83.2
450 72.2 75.7 83.2 83.2 83.2 83.2 83.2 83.2 83.2
500 72.2 75.7 83.2 83.2 83.2 83.2 83.2 83.2 83.2
cmin
120 150 200 250 300 350 400 450
100 X X 51.7 51.7 51.7 51.7 51.7 51.7
150 X X 65.4 65.4 65.4 65.4 65.4 65.4
200 X X 80.7 80.7 80.7 80.7 80.7 80.7
250 X 97.7 97.7 97.7 97.7 97.7 97.7 97.7
M16 100 200 341.2 300 X 116.3 116.3 116.3 116.3 116.3 116.3 116.3 N/A N/A
350 103.8 116.3 116.3 116.3 116.3 116.3 116.3 116.3
400 103.8 116.3 116.3 116.3 116.3 116.3 116.3 116.3
450 103.8 116.3 116.3 116.3 116.3 116.3 116.3 116.3
500 103.8 116.3 116.3 116.3 116.3 116.3 116.3 116.3
cmin
125 150 200 250 300 350 400 450
100 X X X X X X X X
150 X X X 79.6 79.6 79.6 79.6 79.6
200 X X 95.5 95.5 95.5 95.5 95.5 95.5
250 X X 112.8 112.8 112.8 112.8 112.8 112.8
M20 125 250 533.2 300 X 116.9 131.6 131.6 131.6 131.6 131.6 131.6 N/A N/A
350 124.9 135.4 151.8 151.8 151.8 151.8 151.8 151.8
400 134.1 145.1 162.5 162.5 162.5 162.5 162.5 162.5
450 134.1 145.1 162.5 162.5 162.5 162.5 162.5 162.5
500 134.1 145.1 162.5 162.5 162.5 162.5 162.5 162.5
cmin
150 200 250 300 350 400 450
100 X X X X X X X
150 X X 94.9 94.9 94.9 94.9 94.9
200 X 103.6 111.4 111.4 111.4 111.4 111.4
250 X 120.5 129.2 129.2 129.2 129.2 129.2
M24 150 300 767.6 300 120.2 138.6 148.3 148.3 148.3 148.3 148.3 N/A N/A
350 137.7 158.1 168.8 168.8 168.8 168.8 168.8
400 156.4 178.8 190.5 190.5 190.5 190.5 190.5
450 176.2 200.8 213.6 213.6 213.6 213.6 213.6
500 176.2 200.8 213.6 213.6 213.6 213.6 213.6
Notes:
A. For eccentric loading, multiply Ncbr by the modification factor for eccentrically loaded anchor groups,  ec,N as per Section D.6.2.4.
B. If anchors are affected by more than one edge distance use formulas to calculate Concrete Resistance

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12 s
30 1.22
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°

34 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HSL-3 Heavy Duty Sleeve Anchor 2.0


Table 4 - Factored resistance for 6 equally spaced HSL-3, -G, -B anchors subject to Tensile Loads
in Cracked Concrete (f 'c = 20 MPa)
Nsr - Tension
Spacing, Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Ncbgr - Tension Breakout of Group1,3,4 (kN)
s Group1,5 of Group
Anchor Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
60 100 150 200 250 300 350 400 450
100 X 31.1 31.1 31.1 31.1 31.1 31.1 31.1 31.1
150 37.8 46.2 46.2 46.2 46.2 46.2 46.2 46.2 46.2
200 46.8 56.7 56.7 56.7 56.7 56.7 56.7 56.7 56.7
250 46.8 56.7 56.7 56.7 56.7 56.7 56.7 56.7 56.7
M8 60 120 120.0 300 46.8 56.7 56.7 56.7 56.7 56.7 56.7 56.7 56.7 52.4 N/A
350 46.8 56.7 56.7 56.7 56.7 56.7 56.7 56.7 56.7
400 46.8 56.7 56.7 56.7 56.7 56.7 56.7 56.7 56.7
450 46.8 56.7 56.7 56.7 56.7 56.7 56.7 56.7 56.7
500 46.8 56.7 56.7 56.7 56.7 56.7 56.7 56.7 56.7
cmin
70 100 150 200 250 300 350 400 450
100 X X 49.1 49.1 49.1 49.1 49.1 49.1 49.1
150 X 68.9 70.9 70.9 70.9 70.9 70.9 70.9 70.9
200 X 94.0 96.5 96.5 96.5 96.5 96.5 96.5 96.5
250 84.3 99.5 102.1 102.1 102.1 102.1 102.1 102.1 102.1
M10 70 140 189.6 300 84.3 99.5 102.1 102.1 102.1 102.1 102.1 102.1 102.1 83.8 N/A
350 84.3 99.5 102.1 102.1 102.1 102.1 102.1 102.1 102.1
400 84.3 99.5 102.1 102.1 102.1 102.1 102.1 102.1 102.1
450 84.3 99.5 102.1 102.1 102.1 102.1 102.1 102.1 102.1
500 84.3 99.5 102.1 102.1 102.1 102.1 102.1 102.1 102.1
cmin
90 100 150 200 250 300 350 400 450
100 X X 54.0 54.0 54.0 54.0 54.0 54.0 54.0
150 X X 76.1 76.1 76.1 76.1 76.1 76.1 76.1
200 X X 101.7 101.7 101.7 101.7 101.7 101.7 101.7
250 X 113.6 124.8 124.8 124.8 124.8 124.8 124.8 124.8
M12 80 160 276.0 300 108.2 113.6 124.8 124.8 124.8 124.8 124.8 124.8 124.8 N/A N/A
350 108.2 113.6 124.8 124.8 124.8 124.8 124.8 124.8 124.8
400 108.2 113.6 124.8 124.8 124.8 124.8 124.8 124.8 124.8
450 108.2 113.6 124.8 124.8 124.8 124.8 124.8 124.8 124.8
500 108.2 113.6 124.8 124.8 124.8 124.8 124.8 124.8 124.8
cmin
120 150 200 250 300 350 400 450
100 X X 64.6 64.6 64.6 64.6 64.6 64.6
150 X X 87.2 87.2 87.2 87.2 87.2 87.2
200 X X 113.0 113.0 113.0 113.0 113.0 113.0
250 X 142.1 142.1 142.1 142.1 142.1 142.1 142.1
M16 100 200 511.8 300 X 174.4 174.4 174.4 174.4 174.4 174.4 174.4 N/A N/A
350 155.8 174.4 174.4 174.4 174.4 174.4 174.4 174.4
400 155.8 174.4 174.4 174.4 174.4 174.4 174.4 174.4
450 155.8 174.4 174.4 174.4 174.4 174.4 174.4 174.4
500 155.8 174.4 174.4 174.4 174.4 174.4 174.4 174.4
cmin
125 150 200 250 300 350 400 450
100 X X X X X X X X
150 X X X 102.4 102.4 102.4 102.4 102.4
200 X X 128.7 128.7 128.7 128.7 128.7 128.7
250 X X 158.0 158.0 158.0 158.0 158.0 158.0
M20 125 250 799.8 300 X 168.8 190.1 190.1 190.1 190.1 190.1 190.1 N/A N/A
350 185.2 200.7 225.2 225.2 225.2 225.2 225.2 225.2
400 201.1 217.7 243.8 243.8 243.8 243.8 243.8 243.8
450 201.1 217.7 243.8 243.8 243.8 243.8 243.8 243.8
500 201.1 217.7 243.8 243.8 243.8 243.8 243.8 243.8
cmin
150 200 250 300 350 400 450
100 X X X X X X X
150 X X 118.7 118.7 118.7 118.7 118.7
200 X 135.4 145.7 145.7 145.7 145.7 145.7
250 X 163.5 175.4 175.4 175.4 175.4 175.4
M24 150 300 1151.4 300 168.2 194.1 207.7 207.7 207.7 207.7 207.7 N/A N/A
350 197.9 227.2 242.6 242.6 242.6 242.6 242.6
400 229.9 262.9 280.2 280.2 280.2 280.2 280.2
450 264.3 301.1 320.4 320.4 320.4 320.4 320.4
500 264.3 301.1 320.4 320.4 320.4 320.4 320.4
Notes:
A. For eccentric loading, multiply Ncbr by the modification factor for eccentrically loaded anchor groups,  ec,N as per Section D.6.2.4.
B. If anchors are affected by more than one edge distance use formulas to calculate Concrete Resistance

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12 s
30 1.22
35 1.32
40 1.41
45 1.50 s
50 1.58
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ° c1 s

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 35
Mechanical Anchoring Systems

2.0 HSL-3 Heavy Duty Sleeve Anchor


Table 5 - Factored resistance for Single HSL-3, -G, -B anchor subject to Shear Loads in Cracked Concrete (f'c = 20 MPa)

Vsr - Shear Vsr - Shear


Concrete Vcpr - Pryout
Size hef Strength of Strength of Vcbr - Shear Breakout (kN)1,2,4,5,6,7
Thickness, h Resistance
Anchor3 Anchor3
HSL-3, -B HSL-3-G c1 - edge distance (mm) kcp X Ncbr
mm kN kN mm cmin 100 150 200 250 300 350 400 450 kN
120 3.1 6.0 9.0 12.0 15.0 18.0 21.0 24.0 27.0
200 3.1 6.7 11.6 15.5 19.4 23.2 27.1 31.0 34.9
300 3.1 6.7 12.3 19.0 23.7 28.5 33.2 38.0 42.7
M8 60 20.5 17.2 400 3.1 6.7 12.3 19.0 26.5 32.9 38.3 43.8 49.3 1.0 x Ncbr
500 3.1 6.7 12.3 19.0 26.5 34.9 42.9 49.0 55.1
600 3.1 6.7 12.3 19.0 26.5 34.9 43.9 53.7 60.4
675 3.1 6.7 12.3 19.0 26.5 34.9 43.9 53.7 64.0
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
140 4.4 7.2 10.9 14.5 18.1 21.7 25.4 29.0 32.6
200 4.4 7.5 13.0 17.3 21.7 26.0 30.3 34.6 39.0
300 4.4 7.5 13.8 21.2 26.5 31.8 37.1 42.4 47.7
M10 70 29 23.8 400 4.4 7.5 13.8 21.2 29.6 36.7 42.9 49.0 55.1 2.0 x Ncbr
500 4.4 7.5 13.8 21.2 29.6 39.0 47.9 54.8 61.6
600 4.4 7.5 13.8 21.2 29.6 39.0 49.1 60.0 67.5
675 4.4 7.5 13.8 21.2 29.6 39.0 49.1 60.0 71.6
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
160 7.0 8.2 12.7 17.0 21.2 25.5 29.7 33.9 38.2
200 7.0 8.2 14.2 19.0 23.7 28.5 33.2 38.0 42.7
300 7.0 8.2 15.1 23.2 29.1 34.9 40.7 46.5 52.3
M12 80 41.8 34.5 400 7.0 8.2 15.1 23.2 32.5 40.3 47.0 53.7 60.4 2.0 x Ncbr
500 7.0 8.2 15.1 23.2 32.5 42.7 52.5 60.0 67.5
600 7.0 8.2 15.1 23.2 32.5 42.7 53.8 65.7 74.0
675 7.0 8.2 15.1 23.2 32.5 42.7 53.8 65.7 78.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
200 12.5 X 16.4 21.9 27.4 32.9 38.3 43.8 49.3
300 12.5 X 17.4 26.8 33.5 40.3 47.0 53.7 60.4
400 12.5 X 17.4 26.8 37.5 46.5 54.2 62.0 69.7
M16 100 75.7 64.3 2.0 x Ncbr
500 12.5 X 17.4 26.8 37.5 49.3 60.6 69.3 78.0
600 12.5 X 17.4 26.8 37.5 49.3 62.1 75.9 85.4
675 12.5 X 17.4 26.8 37.5 49.3 62.1 75.9 90.6
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
250 14.3 X 18.8 26.5 33.1 39.7 46.3 52.9 59.5
300 14.3 X 18.8 29.0 36.2 43.5 50.7 58.0 65.2
400 14.3 X 18.8 29.0 40.5 50.2 58.6 66.9 75.3 2.0 x Ncbr
M20 125 112.1 94
500 14.3 X 18.8 29.0 40.5 53.3 65.5 74.8 84.2
600 14.3 X 18.8 29.0 40.5 53.3 67.1 82.0 92.2
675 14.3 X 18.8 29.0 40.5 53.3 67.1 82.0 97.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
300 20.1 X 20.1 31.0 38.7 46.5 54.2 62.0 69.7
400 20.1 X 20.1 31.0 43.3 53.7 62.6 71.6 80.5
M24 150 130.3 500 20.1 X 20.1 31.0 43.3 56.9 70.0 80.0 90.0 2.0 x Ncbr
600 20.1 X 20.1 31.0 43.3 56.9 71.7 87.6 98.6
675 20.1 X 20.1 31.0 43.3 56.9 71.7 87.6 104.6

Influence of Concrete Strength, fb

f'c (MPa) fb
20 1.00
25 1.12 V
30 1.22
35 1.32
40 1.41
45 1.50
50 1.58 c1
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°

36 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HSL-3 Heavy Duty Sleeve Anchor 2.0


Table 6 - Factored resistance for 2 or 4 HSL-3, -G, -B anchors subject to Shear Loads in Cracked Concrete (f 'c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete 1,2,4,5,6,7 Vcpgr - Pryout
Size hef Spacing, s Vcbgr - Shear Breakout (kN)
Anchor (kN)3 Anchor (kN)
3
Thickness, h Resistance

HSL-3, -B HSL-3-G c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 8.0 11.0 14.0 17.0 20.0 23.0 26.0 29.0
150 5.7 9.0 12.0 15.0 18.0 21.0 24.0 27.0 30.0
200 6.2 10.0 13.0 16.0 19.0 22.0 25.0 28.0 31.0
250 6.2 11.0 14.0 17.0 20.0 23.0 26.0 29.0 32.0
M8 60 41.0 82.0 34.4 68.8 120 300 6.2 12.0 15.0 18.0 21.0 24.0 27.0 30.0 33.0 1.0 x Ncbgr
350 6.2 12.0 16.0 19.0 22.0 25.0 28.0 31.0 34.0
400 6.2 12.0 17.0 20.0 23.0 26.0 29.0 32.0 35.0
450 6.2 12.0 18.0 21.0 24.0 27.0 30.0 33.0 36.0
500 6.2 12.0 18.0 22.0 25.0 28.0 31.0 34.0 37.0
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 8.9 14.2 18.1 21.9 25.8 29.7 33.6 37.4
150 5.7 10.1 15.5 19.4 23.2 27.1 31.0 34.9 38.7
200 6.2 11.2 16.8 20.7 24.5 28.4 32.3 36.2 40.0
250 6.2 12.3 18.1 21.9 25.8 29.7 33.6 37.4 41.3
M8 60 41.0 82.0 34.4 68.8 200 300 6.2 13.4 19.4 23.2 27.1 31.0 34.9 38.7 42.6 1.0 x Ncbgr
350 6.2 13.4 20.7 24.5 28.4 32.3 36.2 40.0 43.9
400 6.2 13.4 21.9 25.8 29.7 33.6 37.4 41.3 45.2
450 6.2 13.4 23.2 27.1 31.0 34.9 38.7 42.6 46.5
500 6.2 13.4 23.3 28.4 32.3 36.2 40.0 43.9 47.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 8.9 15.1 22.1 26.9 31.6 36.4 41.1 45.9
150 5.7 10.1 16.4 23.7 28.5 33.2 38.0 42.7 47.4
200 6.2 11.2 17.8 25.3 30.0 34.8 39.5 44.3 49.0
250 6.2 12.3 19.2 26.9 31.6 36.4 41.1 45.9 50.6
M8 60 41.0 82.0 34.4 68.8 300 300 6.2 13.4 20.5 28.5 33.2 38.0 42.7 47.4 52.2 1.0 x Ncbgr
350 6.2 13.4 21.9 30.0 34.8 39.5 44.3 49.0 53.8
400 6.2 13.4 23.3 31.6 36.4 41.1 45.9 50.6 55.3
450 6.2 13.4 24.7 33.2 38.0 42.7 47.4 52.2 56.9
500 6.2 13.4 24.7 34.8 39.5 44.3 49.0 53.8 58.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 8.9 15.1 22.1 30.1 36.5 42.0 47.5 53.0
150 5.7 10.1 16.4 23.7 31.8 38.3 43.8 49.3 54.8
200 6.2 11.2 17.8 25.3 33.6 40.2 45.6 51.1 56.6
250 6.2 12.3 19.2 26.9 35.4 42.0 47.5 53.0 58.4
M8 60 41.0 82.0 34.4 68.8 400 300 6.2 13.4 20.5 28.5 37.1 43.8 49.3 54.8 60.3 1.0 x Ncbgr
350 6.2 13.4 21.9 30.0 38.9 45.6 51.1 56.6 62.1
400 6.2 13.4 23.3 31.6 40.7 47.5 53.0 58.4 63.9
450 6.2 13.4 24.7 33.2 42.4 49.3 54.8 60.3 65.7
500 6.2 13.4 24.7 34.8 44.2 51.1 56.6 62.1 67.6
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 8.9 15.1 22.1 30.1 38.7 47.0 53.1 59.2
150 5.7 10.1 16.4 23.7 31.8 40.7 49.0 55.1 61.2
200 6.2 11.2 17.8 25.3 33.6 42.6 51.0 57.2 63.3
250 6.2 12.3 19.2 26.9 35.4 44.5 53.1 59.2 65.3
M8 60 41.0 82.0 34.4 68.8 500 300 6.2 13.4 20.5 28.5 37.1 46.5 55.1 61.2 67.4 1.0 x Ncbgr
350 6.2 13.4 21.9 30.0 38.9 48.4 57.2 63.3 69.4
400 6.2 13.4 23.3 31.6 40.7 50.4 59.2 65.3 71.5
450 6.2 13.4 24.7 33.2 42.4 52.3 61.2 67.4 73.5
500 6.2 13.4 24.7 34.8 44.2 54.2 63.3 69.4 75.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 8.9 15.1 22.1 30.1 38.7 48.1 58.1 64.9
150 5.7 10.1 16.4 23.7 31.8 40.7 50.2 60.4 67.1
200 6.2 11.2 17.8 25.3 33.6 42.6 52.3 62.6 69.3
250 6.2 12.3 19.2 26.9 35.4 44.5 54.4 64.9 71.6
M8 60 41.0 82.0 34.4 68.8 600 300 6.2 13.4 20.5 28.5 37.1 46.5 56.5 67.1 73.8 1.0 x Ncbgr
350 6.2 13.4 21.9 30.0 38.9 48.4 58.6 69.3 76.0
400 6.2 13.4 23.3 31.6 40.7 50.4 60.7 71.6 78.3
450 6.2 13.4 24.7 33.2 42.4 52.3 62.8 73.8 80.5
500 6.2 13.4 24.7 34.8 44.2 54.2 64.8 76.0 82.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 8.9 15.1 22.1 30.1 38.7 48.1 58.1 68.8
150 5.7 10.1 16.4 23.7 31.8 40.7 50.2 60.4 71.2
200 6.2 11.2 17.8 25.3 33.6 42.6 52.3 62.6 73.5
250 6.2 12.3 19.2 26.9 35.4 44.5 54.4 64.9 75.9
M8 60 41.0 82.0 34.4 68.8 675 300 6.2 13.4 20.5 28.5 37.1 46.5 56.5 67.1 78.3 1.0 x Ncbgr
350 6.2 13.4 21.9 30.0 38.9 48.4 58.6 69.3 80.6
400 6.2 13.4 23.3 31.6 40.7 50.4 60.7 71.6 83.0
450 6.2 13.4 24.7 33.2 42.4 52.3 62.8 73.8 85.4
500 6.2 13.4 24.7 34.8 44.2 54.2 64.8 76.0 87.8

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 37
Mechanical Anchoring Systems

2.0 HSL-3 Heavy Duty Sleeve Anchor


Table 7 - Factored resistance for 2 or 4 HSL-3, -G, -B anchors subject to Shear Loads in Cracked Concrete (f 'c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HSL-3, -B HSL-3-G c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X X 13.3 16.9 20.5 24.2 27.8 31.4 35.0
150 X 10.9 14.5 18.1 21.7 25.4 29.0 32.6 36.2
200 X 12.1 15.7 19.3 22.9 26.6 30.2 33.8 37.4
250 8.8 13.3 16.9 20.5 24.2 27.8 31.4 35.0 38.6
M10 70 58.0 116.0 47.6 95.2 140 300 8.8 14.5 18.1 21.7 25.4 29.0 32.6 36.2 39.9 2.0 x Ncbgr
350 8.8 14.5 19.3 22.9 26.6 30.2 33.8 37.4 41.1
400 8.8 14.5 20.5 24.2 27.8 31.4 35.0 38.6 42.3
450 8.8 14.5 21.7 25.4 29.0 32.6 36.2 39.9 43.5
500 8.8 14.5 21.7 26.6 30.2 33.8 37.4 41.1 44.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 15.9 20.2 24.5 28.9 33.2 37.5 41.9
150 X 11.3 17.3 21.7 26.0 30.3 34.6 39.0 43.3
200 X 12.5 18.8 23.1 27.4 31.8 36.1 40.4 44.7
250 8.8 13.8 20.2 24.5 28.9 33.2 37.5 41.9 46.2
M10 70 58.0 116.0 47.6 95.2 200 300 8.8 15.0 21.7 26.0 30.3 34.6 39.0 43.3 47.6 2.0 x Ncbgr
350 8.8 15.0 23.1 27.4 31.8 36.1 40.4 44.7 49.1
400 8.8 15.0 24.5 28.9 33.2 37.5 41.9 46.2 50.5
450 8.8 15.0 26.0 30.3 34.6 39.0 43.3 47.6 52.0
500 8.8 15.0 26.0 31.8 36.1 40.4 44.7 49.1 53.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 16.8 24.8 30.1 35.4 40.7 46.0 51.3
150 X 11.3 18.4 26.5 31.8 37.1 42.4 47.7 53.0
200 X 12.5 19.9 28.3 33.6 38.9 44.2 49.5 54.8
250 8.8 13.8 21.4 30.1 35.4 40.7 46.0 51.3 56.6
M10 70 58.0 116.0 47.6 95.2 300 300 8.8 15.0 23.0 31.8 37.1 42.4 47.7 53.0 58.3 2.0 x Ncbgr
350 8.8 15.0 24.5 33.6 38.9 44.2 49.5 54.8 60.1
400 8.8 15.0 26.0 35.4 40.7 46.0 51.3 56.6 61.9
450 8.8 15.0 27.6 37.1 42.4 47.7 53.0 58.3 63.6
500 8.8 15.0 27.6 38.9 44.2 49.5 54.8 60.1 65.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 16.8 24.8 33.6 40.8 47.0 53.1 59.2
150 X 11.3 18.4 26.5 35.6 42.9 49.0 55.1 61.2
200 X 12.5 19.9 28.3 37.6 44.9 51.0 57.2 63.3
250 8.8 13.8 21.4 30.1 39.5 47.0 53.1 59.2 65.3
M10 70 58.0 116.0 47.6 95.2 400 300 8.8 15.0 23.0 31.8 41.5 49.0 55.1 61.2 67.4 2.0 x Ncbgr
350 8.8 15.0 24.5 33.6 43.5 51.0 57.2 63.3 69.4
400 8.8 15.0 26.0 35.4 45.5 53.1 59.2 65.3 71.5
450 8.8 15.0 27.6 37.1 47.4 55.1 61.2 67.4 73.5
500 8.8 15.0 27.6 38.9 49.4 57.2 63.3 69.4 75.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 16.8 24.8 33.6 43.3 52.5 59.3 66.2
150 X 11.3 18.4 26.5 35.6 45.5 54.8 61.6 68.5
200 X 12.5 19.9 28.3 37.6 47.6 57.1 63.9 70.8
250 8.8 13.8 21.4 30.1 39.5 49.8 59.3 66.2 73.0
M10 70 58.0 116.0 47.6 95.2 500 300 8.8 15.0 23.0 31.8 41.5 52.0 61.6 68.5 75.3 2.0 x Ncbgr
350 8.8 15.0 24.5 33.6 43.5 54.1 63.9 70.8 77.6
400 8.8 15.0 26.0 35.4 45.5 56.3 66.2 73.0 79.9
450 8.8 15.0 27.6 37.1 47.4 58.5 68.5 75.3 82.2
500 8.8 15.0 27.6 38.9 49.4 60.6 70.8 77.6 84.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 16.8 24.8 33.6 43.3 53.8 65.0 72.5
150 X 11.3 18.4 26.5 35.6 45.5 56.1 67.5 75.0
200 X 12.5 19.9 28.3 37.6 47.6 58.5 70.0 77.5
250 8.8 13.8 21.4 30.1 39.5 49.8 60.8 72.5 80.0
M10 70 58.0 116.0 47.6 95.2 600 300 8.8 15.0 23.0 31.8 41.5 52.0 63.1 75.0 82.5 2.0 x Ncbgr
350 8.8 15.0 24.5 33.6 43.5 54.1 65.5 77.5 85.0
400 8.8 15.0 26.0 35.4 45.5 56.3 67.8 80.0 87.5
450 8.8 15.0 27.6 37.1 47.4 58.5 70.2 82.5 90.0
500 8.8 15.0 27.6 38.9 49.4 60.6 72.5 85.0 92.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 16.8 24.8 33.6 43.3 53.8 65.0 76.9
150 X 11.3 18.4 26.5 35.6 45.5 56.1 67.5 79.6
200 X 12.5 19.9 28.3 37.6 47.6 58.5 70.0 82.2
250 8.8 13.8 21.4 30.1 39.5 49.8 60.8 72.5 84.9
M10 70 58.0 116.0 47.6 95.2 675 300 8.8 15.0 23.0 31.8 41.5 52.0 63.1 75.0 87.5 2.0 x Ncbgr
350 8.8 15.0 24.5 33.6 43.5 54.1 65.5 77.5 90.2
400 8.8 15.0 26.0 35.4 45.5 56.3 67.8 80.0 92.8
450 8.8 15.0 27.6 37.1 47.4 58.5 70.2 82.5 95.5
500 8.8 15.0 27.6 38.9 49.4 60.6 72.5 85.0 98.1

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°

38 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HSL-3 Heavy Duty Sleeve Anchor 2.0


Table 8 - Factored resistance for 2 or 4 HSL-3, -G, -B anchors subject to Shear Loads in Cracked Concrete (f 'c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete 1,2,4,5,6,7 Vcpgr - Pryout
Size hef Spacing, s Vcbgr - Shear Breakout (kN)
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HSL-3, -B HSL-3-G c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X X 15.6 19.8 24.0 28.3 32.5 36.8 41.0
150 X X 17.0 21.2 25.5 29.7 33.9 38.2 42.4
200 X X 18.4 22.6 26.9 31.1 35.4 39.6 43.8
250 X 15.1 19.8 24.0 28.3 32.5 36.8 41.0 45.3
M12 80 83.6 167.2 69.0 138.0 160 300 14.0 16.4 21.2 25.5 29.7 33.9 38.2 42.4 46.7 2.0 x Ncbgr
350 14.0 16.4 22.6 26.9 31.1 35.4 39.6 43.8 48.1
400 14.0 16.4 24.0 28.3 32.5 36.8 41.0 45.3 49.5
450 14.0 16.4 25.5 29.7 33.9 38.2 42.4 46.7 50.9
500 14.0 16.4 25.5 31.1 35.4 39.6 43.8 48.1 52.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 17.4 22.1 26.9 31.6 36.4 41.1 45.9
150 X X 19.0 23.7 28.5 33.2 38.0 42.7 47.4
200 X X 20.6 25.3 30.0 34.8 39.5 44.3 49.0
250 X 15.1 22.1 26.9 31.6 36.4 41.1 45.9 50.6
M12 80 83.6 167.2 69.0 138.0 200 300 14.0 16.4 23.7 28.5 33.2 38.0 42.7 47.4 52.2 2.0 x Ncbgr
350 14.0 16.4 25.3 30.0 34.8 39.5 44.3 49.0 53.8
400 14.0 16.4 26.9 31.6 36.4 41.1 45.9 50.6 55.3
450 14.0 16.4 28.5 33.2 38.0 42.7 47.4 52.2 56.9
500 14.0 16.4 28.5 34.8 39.5 44.3 49.0 53.8 58.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 18.4 27.1 32.9 38.7 44.5 50.4 56.2
150 X X 20.1 29.1 34.9 40.7 46.5 52.3 58.1
200 X X 21.8 31.0 36.8 42.6 48.4 54.2 60.0
250 X 15.1 23.5 32.9 38.7 44.5 50.4 56.2 62.0
M12 80 83.6 167.2 69.0 138.0 300 300 14.0 16.4 25.2 34.9 40.7 46.5 52.3 58.1 63.9 2.0 x Ncbgr
350 14.0 16.4 26.8 36.8 42.6 48.4 54.2 60.0 65.8
400 14.0 16.4 28.5 38.7 44.5 50.4 56.2 62.0 67.8
450 14.0 16.4 30.2 40.7 46.5 52.3 58.1 63.9 69.7
500 14.0 16.4 30.2 42.6 48.4 54.2 60.0 65.8 71.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 18.4 27.1 36.8 44.7 51.4 58.1 64.9
150 X X 20.1 29.1 39.0 47.0 53.7 60.4 67.1
200 X X 21.8 31.0 41.1 49.2 55.9 62.6 69.3
250 X 15.1 23.5 32.9 43.3 51.4 58.1 64.9 71.6
M12 80 83.6 167.2 69.0 138.0 400 300 14.0 16.4 25.2 34.9 45.5 53.7 60.4 67.1 73.8 2.0 x Ncbgr
350 14.0 16.4 26.8 36.8 47.6 55.9 62.6 69.3 76.0
400 14.0 16.4 28.5 38.7 49.8 58.1 64.9 71.6 78.3
450 14.0 16.4 30.2 40.7 52.0 60.4 67.1 73.8 80.5
500 14.0 16.4 30.2 42.6 54.1 62.6 69.3 76.0 82.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 18.4 27.1 36.8 47.4 57.5 65.0 72.5
150 X X 20.1 29.1 39.0 49.8 60.0 67.5 75.0
200 X X 21.8 31.0 41.1 52.2 62.5 70.0 77.5
250 X 15.1 23.5 32.9 43.3 54.6 65.0 72.5 80.0
M12 80 83.6 167.2 69.0 138.0 500 300 14.0 16.4 25.2 34.9 45.5 56.9 67.5 75.0 82.5 2.0 x Ncbgr
350 14.0 16.4 26.8 36.8 47.6 59.3 70.0 77.5 85.0
400 14.0 16.4 28.5 38.7 49.8 61.7 72.5 80.0 87.5
450 14.0 16.4 30.2 40.7 52.0 64.0 75.0 82.5 90.0
500 14.0 16.4 30.2 42.6 54.1 66.4 77.5 85.0 92.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 18.4 27.1 36.8 47.4 58.9 71.2 79.4
150 X X 20.1 29.1 39.0 49.8 61.5 74.0 82.2
200 X X 21.8 31.0 41.1 52.2 64.1 76.7 84.9
250 X 15.1 23.5 32.9 43.3 54.6 66.6 79.4 87.6
M12 80 83.6 167.2 69.0 138.0 600 300 14.0 16.4 25.2 34.9 45.5 56.9 69.2 82.2 90.4 2.0 x Ncbgr
350 14.0 16.4 26.8 36.8 47.6 59.3 71.7 84.9 93.1
400 14.0 16.4 28.5 38.7 49.8 61.7 74.3 87.6 95.9
450 14.0 16.4 30.2 40.7 52.0 64.0 76.9 90.4 98.6
500 14.0 16.4 30.2 42.6 54.1 66.4 79.4 93.1 101.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 18.4 27.1 36.8 47.4 58.9 71.2 84.2
150 X X 20.1 29.1 39.0 49.8 61.5 74.0 87.2
200 X X 21.8 31.0 41.1 52.2 64.1 76.7 90.1
250 X 15.1 23.5 32.9 43.3 54.6 66.6 79.4 93.0
M12 80 83.6 167.2 69.0 138.0 675 300 14.0 16.4 25.2 34.9 45.5 56.9 69.2 82.2 95.9 2.0 x Ncbgr
350 14.0 16.4 26.8 36.8 47.6 59.3 71.7 84.9 98.8
400 14.0 16.4 28.5 38.7 49.8 61.7 74.3 87.6 101.7
450 14.0 16.4 30.2 40.7 52.0 64.0 76.9 90.4 104.6
500 14.0 16.4 30.2 42.6 54.1 66.4 79.4 93.1 107.5

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 39
Mechanical Anchoring Systems

2.0 HSL-3 Heavy Duty Sleeve Anchor


Table 9 - Factored resistance for 2 or 4 HSL-3, -G, -B anchors subject to Shear Loads in Cracked Concrete (f'c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN)1,2,4,5,6,7
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HSL-3, -B HSL-3-G c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts 2 Bolts 4 Bolts mm mm cmin 150 200 250 300 350 400 450 kN
100 X X 25.6 31.0 36.5 42.0 47.5 53.0
150 X X 27.4 32.9 38.3 43.8 49.3 54.8
200 X X 29.2 34.7 40.2 45.6 51.1 56.6
250 X 25.6 31.0 36.5 42.0 47.5 53.0 58.4
M16 100 151.4 302.8 128.6 257.2 200 300 X 27.4 32.9 38.3 43.8 49.3 54.8 60.3 2.0 x Ncbgr
350 24.6 29.2 34.7 40.2 45.6 51.1 56.6 62.1
400 24.9 31.0 36.5 42.0 47.5 53.0 58.4 63.9
450 24.9 32.9 38.3 43.8 49.3 54.8 60.3 65.7
500 24.9 32.9 40.2 45.6 51.1 56.6 62.1 67.6
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
100 X X 31.3 38.0 44.7 51.4 58.1 64.9
150 X X 33.5 40.3 47.0 53.7 60.4 67.1
200 X X 35.8 42.5 49.2 55.9 62.6 69.3
250 X 27.1 38.0 44.7 51.4 58.1 64.9 71.6
M16 100 151.4 302.8 128.6 257.2 300 300 X 29.1 40.3 47.0 53.7 60.4 67.1 73.8 2.0 x Ncbgr
350 24.6 31.0 42.5 49.2 55.9 62.6 69.3 76.0
400 24.9 32.9 44.7 51.4 58.1 64.9 71.6 78.3
450 24.9 34.9 47.0 53.7 60.4 67.1 73.8 80.5
500 24.9 34.9 49.2 55.9 62.6 69.3 76.0 82.7
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
100 X X 31.3 42.5 51.6 59.4 67.1 74.9
150 X X 33.5 45.0 54.2 62.0 69.7 77.5
200 X X 35.8 47.5 56.8 64.6 72.3 80.1
250 X 27.1 38.0 50.0 59.4 67.1 74.9 82.6
M16 100 151.4 302.8 128.6 257.2 400 300 X 29.1 40.3 52.5 62.0 69.7 77.5 85.2 2.0 x Ncbgr
350 24.6 31.0 42.5 55.0 64.6 72.3 80.1 87.8
400 24.9 32.9 44.7 57.5 67.1 74.9 82.6 90.4
450 24.9 34.9 47.0 60.0 69.7 77.5 85.2 93.0
500 24.9 34.9 49.2 62.5 72.3 80.1 87.8 95.5
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
100 X X 31.3 42.5 54.8 66.4 75.1 83.7
150 X X 33.5 45.0 57.5 69.3 78.0 86.6
200 X X 35.8 47.5 60.3 72.2 80.8 89.5
250 X 27.1 38.0 50.0 63.0 75.1 83.7 92.4
M16 100 151.4 302.8 128.6 257.2 500 300 X 29.1 40.3 52.5 65.7 78.0 86.6 95.3 2.0 x Ncbgr
350 24.6 31.0 42.5 55.0 68.5 80.8 89.5 98.2
400 24.9 32.9 44.7 57.5 71.2 83.7 92.4 101.0
450 24.9 34.9 47.0 60.0 74.0 86.6 95.3 103.9
500 24.9 34.9 49.2 62.5 76.7 89.5 98.2 106.8
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
100 X X 31.3 42.5 54.8 68.0 82.2 91.7
150 X X 33.5 45.0 57.5 71.0 85.4 94.9
200 X X 35.8 47.5 60.3 74.0 88.6 98.0
250 X 27.1 38.0 50.0 63.0 76.9 91.7 101.2
M16 100 151.4 302.8 128.6 257.2 600 300 X 29.1 40.3 52.5 65.7 79.9 94.9 104.4 2.0 x Ncbgr
350 24.6 31.0 42.5 55.0 68.5 82.8 98.0 107.5
400 24.9 32.9 44.7 57.5 71.2 85.8 101.2 110.7
450 24.9 34.9 47.0 60.0 74.0 88.8 104.4 113.9
500 24.9 34.9 49.2 62.5 76.7 91.7 107.5 117.0
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
100 X X 31.3 42.5 54.8 68.0 82.2 97.3
150 X X 33.5 45.0 57.5 71.0 85.4 100.6
200 X X 35.8 47.5 60.3 74.0 88.6 104.0
250 X 27.1 38.0 50.0 63.0 76.9 91.7 107.3
M16 100 151.4 302.8 128.6 257.2 675 300 X 29.1 40.3 52.5 65.7 79.9 94.9 110.7 2.0 x Ncbgr
350 24.6 31.0 42.5 55.0 68.5 82.8 98.0 114.1
400 24.9 32.9 44.7 57.5 71.2 85.8 101.2 117.4
450 24.9 34.9 47.0 60.0 74.0 88.8 104.4 120.8
500 24.9 34.9 49.2 62.5 76.7 91.7 107.5 124.1

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°

40 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HSL-3 Heavy Duty Sleeve Anchor 2.0


Table 10 - Factored resistance for 2 or 4 HSL-3, -G, -B anchors subject to Shear Loads in Cracked Concrete (f'c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN)1,2,4,5,6,7
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HSL-3, -B HSL-3-G c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts 2 Bolts 4 Bolts mm mm cmin 150 200 250 300 350 400 450 kN
150 X X X 39.7 46.3 52.9 59.5 66.2
200 X X 35.3 41.9 48.5 55.1 61.7 68.4
250 X X 37.5 44.1 50.7 57.3 63.9 70.6
300 X 31.4 39.7 46.3 52.9 59.5 66.2 72.8
M20 125 224.2 448.4 188.0 376.0 250 2.0 x Ncbgr
350 27.7 33.5 41.9 48.5 55.1 61.7 68.4 75.0
400 28.6 35.6 44.1 50.7 57.3 63.9 70.6 77.2
450 28.6 37.7 46.3 52.9 59.5 66.2 72.8 79.4
500 28.6 37.7 48.5 55.1 61.7 68.4 75.0 81.6
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 43.5 50.7 58.0 65.2 72.5
200 X X 38.6 45.9 53.1 60.4 67.6 74.9
250 X X 41.1 48.3 55.6 62.8 70.0 77.3
300 X 31.4 43.5 50.7 58.0 65.2 72.5 79.7
M20 125 224.2 448.4 188.0 376.0 300 2.0 x Ncbgr
350 27.7 33.5 45.9 53.1 60.4 67.6 74.9 82.1
400 28.6 35.6 48.3 55.6 62.8 70.0 77.3 84.5
450 28.6 37.7 50.7 58.0 65.2 72.5 79.7 87.0
500 28.6 37.7 53.1 60.4 67.6 74.9 82.1 89.4
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 48.6 58.6 66.9 75.3 83.7
200 X X 38.6 51.3 61.4 69.7 78.1 86.5
250 X X 41.1 54.0 64.2 72.5 80.9 89.3
300 X 31.4 43.5 56.7 66.9 75.3 83.7 92.0
M20 125 224.2 448.4 188.0 376.0 400 2.0 x Ncbgr
350 27.7 33.5 45.9 59.4 69.7 78.1 86.5 94.8
400 28.6 35.6 48.3 62.1 72.5 80.9 89.3 97.6
450 28.6 37.7 50.7 64.8 75.3 83.7 92.0 100.4
500 28.6 37.7 53.1 67.5 78.1 86.5 94.8 103.2
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 48.6 62.1 74.8 84.2 93.6
200 X X 38.6 51.3 65.1 78.0 87.3 96.7
250 X X 41.1 54.0 68.0 81.1 90.4 99.8
300 X 31.4 43.5 56.7 71.0 84.2 93.6 102.9
M20 125 224.2 448.4 188.0 376.0 500 2.0 x Ncbgr
350 27.7 33.5 45.9 59.4 74.0 87.3 96.7 106.0
400 28.6 35.6 48.3 62.1 76.9 90.4 99.8 109.1
450 28.6 37.7 50.7 64.8 79.9 93.6 102.9 112.3
500 28.6 37.7 53.1 67.5 82.8 96.7 106.0 115.4
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 48.6 62.1 76.7 92.2 102.5
200 X X 38.6 51.3 65.1 79.9 95.6 105.9
250 X X 41.1 54.0 68.0 83.1 99.1 109.3
300 X 31.4 43.5 56.7 71.0 86.3 102.5 112.7
M20 125 224.2 448.4 188.0 376.0 600 2.0 x Ncbgr
350 27.7 33.5 45.9 59.4 74.0 89.5 105.9 116.1
400 28.6 35.6 48.3 62.1 76.9 92.7 109.3 119.6
450 28.6 37.7 50.7 64.8 79.9 95.9 112.7 123.0
500 28.6 37.7 53.1 67.5 82.8 99.1 116.1 126.4
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 48.6 62.1 76.7 92.2 108.7
200 X X 38.6 51.3 65.1 79.9 95.6 112.3
250 X X 41.1 54.0 68.0 83.1 99.1 115.9
300 X 31.4 43.5 56.7 71.0 86.3 102.5 119.6
M20 125 224.2 448.4 188.0 376.0 675 2.0 x Ncbgr
350 27.7 33.5 45.9 59.4 74.0 89.5 105.9 123.2
400 28.6 35.6 48.3 62.1 76.9 92.7 109.3 126.8
450 28.6 37.7 50.7 64.8 79.9 95.9 112.7 130.4
500 28.6 37.7 53.1 67.5 82.8 99.1 116.1 134.1

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1
c1 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 41
Mechanical Anchoring Systems

2.0 HSL-3 Heavy Duty Sleeve Anchor


Table 11 - Factored resistance for 2 or 4 HSL-3, -G, -B anchors subject to Shear Loads in Cracked Concrete (f'c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN)1,2,4,5,6,7
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HSL-3, -B HSL-3-G c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts 2 Bolts 4 Bolts mm mm cmin 150 200 250 300 350 400 450 kN
150 X X X 46.5 54.2 62.0 69.7 77.5
200 X X 41.3 49.1 56.8 64.6 72.3 80.1
250 X X 43.9 51.6 59.4 67.1 74.9 82.6
300 33.5 33.5 46.5 54.2 62.0 69.7 77.5 85.2
M24 150 260.6 521.2 N/A N/A 300 2.0 x Ncbgr
350 35.8 35.8 49.1 56.8 64.6 72.3 80.1 87.8
400 38.0 38.0 51.6 59.4 67.1 74.9 82.6 90.4
450 40.3 40.3 54.2 62.0 69.7 77.5 85.2 93.0
500 40.3 40.3 56.8 64.6 72.3 80.1 87.8 95.5
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 52.0 62.6 71.6 80.5 89.5
200 X X 41.3 54.9 65.6 74.5 83.5 92.4
250 X X 43.9 57.7 68.6 77.5 86.5 95.4
300 33.5 33.5 46.5 60.6 71.6 80.5 89.5 98.4
M24 150 390.9 781.8 N/A N/A 400 2.0 x Ncbgr
350 35.8 35.8 49.1 63.5 74.5 83.5 92.4 101.4
400 38.0 38.0 51.6 66.4 77.5 86.5 95.4 104.4
450 40.3 40.3 54.2 69.3 80.5 89.5 98.4 107.3
500 40.3 40.3 56.8 72.2 83.5 92.4 101.4 110.3
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 52.0 66.4 80.0 90.0 100.0
200 X X 41.3 54.9 69.6 83.3 93.3 103.3
250 X X 43.9 57.7 72.7 86.7 96.7 106.7
300 33.5 33.5 46.5 60.6 75.9 90.0 100.0 110.0
M24 150 260.6 521.2 N/A N/A 500 2.0 x Ncbgr
350 35.8 35.8 49.1 63.5 79.1 93.3 103.3 113.3
400 38.0 38.0 51.6 66.4 82.2 96.7 106.7 116.7
450 40.3 40.3 54.2 69.3 85.4 100.0 110.0 120.0
500 40.3 40.3 56.8 72.2 88.6 103.3 113.3 123.3
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 52.0 66.4 82.0 98.6 109.6
200 X X 41.3 54.9 69.6 85.4 102.3 113.2
250 X X 43.9 57.7 72.7 88.8 105.9 116.9
300 33.5 33.5 46.5 60.6 75.9 92.2 109.6 120.5
M24 150 260.6 521.2 N/A N/A 600 2.0 x Ncbgr
350 35.8 35.8 49.1 63.5 79.1 95.6 113.2 124.2
400 38.0 38.0 51.6 66.4 82.2 99.1 116.9 127.8
450 40.3 40.3 54.2 69.3 85.4 102.5 120.5 131.5
500 40.3 40.3 56.8 72.2 88.6 105.9 124.2 135.1
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 52.0 66.4 82.0 98.6 116.2
200 X X 41.3 54.9 69.6 85.4 102.3 120.1
250 X X 43.9 57.7 72.7 88.8 105.9 123.9
300 33.5 33.5 46.5 60.6 75.9 92.2 109.6 127.8
M24 150 260.6 521.2 N/A N/A 675 2.0 x Ncbgr
350 35.8 35.8 49.1 63.5 79.1 95.6 113.2 131.7
400 38.0 38.0 51.6 66.4 82.2 99.1 116.9 135.6
450 40.3 40.3 54.2 69.3 85.4 102.5 120.5 139.4
500 40.3 40.3 56.8 72.2 88.6 105.9 124.2 143.3

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12 V
30 1.22 s V s
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
c1
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°

42 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HSL-3 Heavy Duty Sleeve Anchor 2.0


Table 12 - Factored resistance for 3 or 6 HSL-3, -G, -B anchors subject to Shear Loads in Cracked Concrete (f'c = 20 MPa)
Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete 1,2,4,5,6,7 Vcpgr - Pryout
Size hef 3 Spacing, s Vcbgr - Shear Breakout (kN)
Anchor (kN) Anchor (kN)3 Thickness, h Resistance

HSL-3, -B HSL-3-G c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 10.0 13.0 16.0 19.0 22.0 25.0 28.0 31.0
150 8.3 12.0 15.0 18.0 21.0 24.0 27.0 30.0 33.0
200 9.4 14.0 17.0 20.0 23.0 26.0 29.0 32.0 35.0
250 9.4 16.0 19.0 22.0 25.0 28.0 31.0 34.0 37.0
M8 60 61.5 123.0 51.6 103.2 120 300 9.4 18.0 21.0 24.0 27.0 30.0 33.0 36.0 39.0 1.0 x Ncbgr
350 9.4 18.0 23.0 26.0 29.0 32.0 35.0 38.0 41.0
400 9.4 18.0 25.0 28.0 31.0 34.0 37.0 40.0 43.0
450 9.4 18.0 27.0 30.0 33.0 36.0 39.0 42.0 45.0
500 9.4 18.0 27.0 32.0 35.0 38.0 41.0 44.0 47.0
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.2 16.8 20.7 24.5 28.4 32.3 36.2 40.0
150 8.3 13.4 19.4 23.2 27.1 31.0 34.9 38.7 42.6
200 9.4 15.7 21.9 25.8 29.7 33.6 37.4 41.3 45.2
250 9.4 17.9 24.5 28.4 32.3 36.2 40.0 43.9 47.8
M8 60 61.5 123.0 51.6 103.2 200 300 9.4 20.1 27.1 31.0 34.9 38.7 42.6 46.5 50.4 1.0 x Ncbgr
350 9.4 20.1 29.7 33.6 37.4 41.3 45.2 49.1 52.9
400 9.4 20.1 32.3 36.2 40.0 43.9 47.8 51.6 55.5
450 9.4 20.1 34.9 38.7 42.6 46.5 50.4 54.2 58.1
500 9.4 20.1 34.9 41.3 45.2 49.1 52.9 56.8 60.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.2 17.8 25.3 30.0 34.8 39.5 44.3 49.0
150 8.3 13.4 20.5 28.5 33.2 38.0 42.7 47.4 52.2
200 9.4 15.7 23.3 31.6 36.4 41.1 45.9 50.6 55.3
250 9.4 17.9 26.0 34.8 39.5 44.3 49.0 53.8 58.5
M8 60 61.5 123.0 51.6 103.2 300 300 9.4 20.1 28.8 38.0 42.7 47.4 52.2 56.9 61.7 1.0 x Ncbgr
350 9.4 20.1 31.5 41.1 45.9 50.6 55.3 60.1 64.8
400 9.4 20.1 34.2 44.3 49.0 53.8 58.5 63.3 68.0
450 9.4 20.1 37.0 47.4 52.2 56.9 61.7 66.4 71.2
500 9.4 20.1 37.0 50.6 55.3 60.1 64.8 69.6 74.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.2 17.8 25.3 33.6 40.2 45.6 51.1 56.6
150 8.3 13.4 20.5 28.5 37.1 43.8 49.3 54.8 60.3
200 9.4 15.7 23.3 31.6 40.7 47.5 53.0 58.4 63.9
250 9.4 17.9 26.0 34.8 44.2 51.1 56.6 62.1 67.6
M8 60 61.5 123.0 51.6 103.2 400 300 9.4 20.1 28.8 38.0 47.7 54.8 60.3 65.7 71.2 1.0 x Ncbgr
350 9.4 20.1 31.5 41.1 51.3 58.4 63.9 69.4 74.9
400 9.4 20.1 34.2 44.3 54.8 62.1 67.6 73.0 78.5
450 9.4 20.1 37.0 47.4 58.3 65.7 71.2 76.7 82.2
500 9.4 20.1 37.0 50.6 61.9 69.4 74.9 80.3 85.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.2 17.8 25.3 33.6 42.6 51.0 57.2 63.3
150 8.3 13.4 20.5 28.5 37.1 46.5 55.1 61.2 67.4
200 9.4 15.7 23.3 31.6 40.7 50.4 59.2 65.3 71.5
250 9.4 17.9 26.0 34.8 44.2 54.2 63.3 69.4 75.5
M8 60 61.5 123.0 51.6 103.2 500 300 9.4 20.1 28.8 38.0 47.7 58.1 67.4 73.5 79.6 1.0 x Ncbgr
350 9.4 20.1 31.5 41.1 51.3 62.0 71.5 77.6 83.7
400 9.4 20.1 34.2 44.3 54.8 65.8 75.5 81.7 87.8
450 9.4 20.1 37.0 47.4 58.3 69.7 79.6 85.7 91.9
500 9.4 20.1 37.0 50.6 61.9 73.6 83.7 89.8 95.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.2 17.8 25.3 33.6 42.6 52.3 62.6 69.3
150 8.3 13.4 20.5 28.5 37.1 46.5 56.5 67.1 73.8
200 9.4 15.7 23.3 31.6 40.7 50.4 60.7 71.6 78.3
250 9.4 17.9 26.0 34.8 44.2 54.2 64.8 76.0 82.7
M8 60 61.5 123.0 51.6 103.2 600 300 9.4 20.1 28.8 38.0 47.7 58.1 69.0 80.5 87.2 1.0 x Ncbgr
350 9.4 20.1 31.5 41.1 51.3 62.0 73.2 85.0 91.7
400 9.4 20.1 34.2 44.3 54.8 65.8 77.4 89.5 96.2
450 9.4 20.1 37.0 47.4 58.3 69.7 81.6 93.9 100.6
500 9.4 20.1 37.0 50.6 61.9 73.6 85.8 98.4 105.1
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.2 17.8 25.3 33.6 42.6 52.3 62.6 73.5
150 8.3 13.4 20.5 28.5 37.1 46.5 56.5 67.1 78.3
200 9.4 15.7 23.3 31.6 40.7 50.4 60.7 71.6 83.0
250 9.4 17.9 26.0 34.8 44.2 54.2 64.8 76.0 87.8
M8 60 61.5 123.0 51.6 103.2 675 300 9.4 20.1 28.8 38.0 47.7 58.1 69.0 80.5 92.5 1.0 x Ncbgr
350 9.4 20.1 31.5 41.1 51.3 62.0 73.2 85.0 97.3
400 9.4 20.1 34.2 44.3 54.8 65.8 77.4 89.5 102.0
450 9.4 20.1 37.0 47.4 58.3 69.7 81.6 93.9 106.7
500 9.4 20.1 37.0 50.6 61.9 73.6 85.8 98.4 111.5

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12
30 1.22 s s
35 1.32
40 1.41 V V
45 1.50
50 1.58 s s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°
c1 c1 s

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 43
Mechanical Anchoring Systems

2.0 HSL-3 Heavy Duty Sleeve Anchor


Table 13 - Factored resistance for 3 or 6 HSL-3, -G, -B anchors subject to Shear Loads in Cracked Concrete (f 'c = 20 MPa)
Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete Vcpgr - Pryout
Size hef Spacing, s Vcbgr - Shear Breakout (kN)1,2,4,5,6,7
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HSL-3, -B HSL-3-G c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X X 15.7 19.3 22.9 26.6 30.2 33.8 37.4
150 X 14.5 18.1 21.7 25.4 29.0 32.6 36.2 39.9
200 X 16.9 20.5 24.2 27.8 31.4 35.0 38.6 42.3
250 13.2 19.3 22.9 26.6 30.2 33.8 37.4 41.1 44.7
M10 70 87.0 174.0 71.4 142.8 140 300 13.2 21.7 25.4 29.0 32.6 36.2 39.9 43.5 47.1 2.0 x Ncbgr
350 13.2 21.7 27.8 31.4 35.0 38.6 42.3 45.9 49.5
400 13.2 21.7 30.2 33.8 37.4 41.1 44.7 48.3 51.9
450 13.2 21.7 32.6 36.2 39.9 43.5 47.1 50.7 54.3
500 13.2 21.7 32.6 38.6 42.3 45.9 49.5 53.1 56.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 18.8 23.1 27.4 31.8 36.1 40.4 44.7
150 X 15.0 21.7 26.0 30.3 34.6 39.0 43.3 47.6
200 X 17.5 24.5 28.9 33.2 37.5 41.9 46.2 50.5
250 13.2 20.0 27.4 31.8 36.1 40.4 44.7 49.1 53.4
M10 70 87.0 174.0 71.4 142.8 200 300 13.2 22.5 30.3 34.6 39.0 43.3 47.6 52.0 56.3 2.0 x Ncbgr
350 13.2 22.5 33.2 37.5 41.9 46.2 50.5 54.9 59.2
400 13.2 22.5 36.1 40.4 44.7 49.1 53.4 57.7 62.1
450 13.2 22.5 39.0 43.3 47.6 52.0 56.3 60.6 65.0
500 13.2 22.5 39.0 46.2 50.5 54.9 59.2 63.5 67.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 19.9 28.3 33.6 38.9 44.2 49.5 54.8
150 X 15.0 23.0 31.8 37.1 42.4 47.7 53.0 58.3
200 X 17.5 26.0 35.4 40.7 46.0 51.3 56.6 61.9
250 13.2 20.0 29.1 38.9 44.2 49.5 54.8 60.1 65.4
M10 70 87.0 174.0 71.4 142.8 300 300 13.2 22.5 32.2 42.4 47.7 53.0 58.3 63.6 69.0 2.0 x Ncbgr
350 13.2 22.5 35.2 46.0 51.3 56.6 61.9 67.2 72.5
400 13.2 22.5 38.3 49.5 54.8 60.1 65.4 70.7 76.0
450 13.2 22.5 41.3 53.0 58.3 63.6 69.0 74.3 79.6
500 13.2 22.5 41.3 56.6 61.9 67.2 72.5 77.8 83.1
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 19.9 28.3 37.6 44.9 51.0 57.2 63.3
150 X 15.0 23.0 31.8 41.5 49.0 55.1 61.2 67.4
200 X 17.5 26.0 35.4 45.5 53.1 59.2 65.3 71.5
250 13.2 20.0 29.1 38.9 49.4 57.2 63.3 69.4 75.5
M10 70 87.0 174.0 71.4 142.8 400 300 13.2 22.5 32.2 42.4 53.4 61.2 67.4 73.5 79.6 2.0 x Ncbgr
350 13.2 22.5 35.2 46.0 57.3 65.3 71.5 77.6 83.7
400 13.2 22.5 38.3 49.5 61.3 69.4 75.5 81.7 87.8
450 13.2 22.5 41.3 53.0 65.2 73.5 79.6 85.7 91.9
500 13.2 22.5 41.3 56.6 69.2 77.6 83.7 89.8 95.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 19.9 28.3 37.6 47.6 57.1 63.9 70.8
150 X 15.0 23.0 31.8 41.5 52.0 61.6 68.5 75.3
200 X 17.5 26.0 35.4 45.5 56.3 66.2 73.0 79.9
250 13.2 20.0 29.1 38.9 49.4 60.6 70.8 77.6 84.4
M10 70 87.0 174.0 71.4 142.8 500 300 13.2 22.5 32.2 42.4 53.4 65.0 75.3 82.2 89.0 2.0 x Ncbgr
350 13.2 22.5 35.2 46.0 57.3 69.3 79.9 86.7 93.6
400 13.2 22.5 38.3 49.5 61.3 73.6 84.4 91.3 98.1
450 13.2 22.5 41.3 53.0 65.2 78.0 89.0 95.9 102.7
500 13.2 22.5 41.3 56.6 69.2 82.3 93.6 100.4 107.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 19.9 28.3 37.6 47.6 58.5 70.0 77.5
150 X 15.0 23.0 31.8 41.5 52.0 63.1 75.0 82.5
200 X 17.5 26.0 35.4 45.5 56.3 67.8 80.0 87.5
250 13.2 20.0 29.1 38.9 49.4 60.6 72.5 85.0 92.5
M10 70 87.0 174.0 71.4 142.8 600 300 13.2 22.5 32.2 42.4 53.4 65.0 77.2 90.0 97.5 2.0 x Ncbgr
350 13.2 22.5 35.2 46.0 57.3 69.3 81.9 95.0 102.5
400 13.2 22.5 38.3 49.5 61.3 73.6 86.5 100.0 107.5
450 13.2 22.5 41.3 53.0 65.2 78.0 91.2 105.0 112.5
500 13.2 22.5 41.3 56.6 69.2 82.3 95.9 110.0 117.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 19.9 28.3 37.6 47.6 58.5 70.0 82.2
150 X 15.0 23.0 31.8 41.5 52.0 63.1 75.0 87.5
200 X 17.5 26.0 35.4 45.5 56.3 67.8 80.0 92.8
250 13.2 20.0 29.1 38.9 49.4 60.6 72.5 85.0 98.1
M10 70 87.0 174.0 71.4 142.8 675 300 13.2 22.5 32.2 42.4 53.4 65.0 77.2 90.0 103.4 2.0 x Ncbgr
350 13.2 22.5 35.2 46.0 57.3 69.3 81.9 95.0 108.7
400 13.2 22.5 38.3 49.5 61.3 73.6 86.5 100.0 114.0
450 13.2 22.5 41.3 53.0 65.2 78.0 91.2 105.0 119.3
500 13.2 22.5 41.3 56.6 69.2 82.3 95.9 110.0 124.6

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12
30 1.22 s s
35 1.32
40 1.41 V V
45 1.50
50 1.58 s s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°
c1 c1 s

44 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HSL-3 Heavy Duty Sleeve Anchor 2.0


Table 14 - Factored resistance for 3 or 6 HSL-3, -G, -B anchors subject to Shear Loads in Cracked Concrete (f 'c = 20 MP
Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete Vcpgr - Pryout
Size hef Spacing, s Vcbgr - Shear Breakout (kN)1,2,4,5,6,7
Anchor (kN)3 Anchor (kN)3 Thickness, h Resistance

HSL-3, -B HSL-3-G c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X X 18.4 22.6 26.9 31.1 35.4 39.6 43.8
150 X X 21.2 25.5 29.7 33.9 38.2 42.4 46.7
200 X X 24.0 28.3 32.5 36.8 41.0 45.3 49.5
250 X 21.9 26.9 31.1 35.4 39.6 43.8 48.1 52.3
M12 80 125.4 250.8 103.5 207 160 300 21.0 24.7 29.7 33.9 38.2 42.4 46.7 50.9 55.2 2.0 x Ncbgr
350 21.0 24.7 32.5 36.8 41.0 45.3 49.5 53.7 58.0
400 21.0 24.7 35.4 39.6 43.8 48.1 52.3 56.6 60.8
450 21.0 24.7 38.2 42.4 46.7 50.9 55.2 59.4 63.6
500 21.0 24.7 38.2 45.3 49.5 53.7 58.0 62.2 66.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 20.6 25.3 30.0 34.8 39.5 44.3 49.0
150 X X 23.7 28.5 33.2 38.0 42.7 47.4 52.2
200 X X 26.9 31.6 36.4 41.1 45.9 50.6 55.3
250 X 21.9 30.0 34.8 39.5 44.3 49.0 53.8 58.5
M12 80 125.4 250.8 103.5 207 200 300 21.0 24.7 33.2 38.0 42.7 47.4 52.2 56.9 61.7 2.0 x Ncbgr
350 21.0 24.7 36.4 41.1 45.9 50.6 55.3 60.1 64.8
400 21.0 24.7 39.5 44.3 49.0 53.8 58.5 63.3 68.0
450 21.0 24.7 42.7 47.4 52.2 56.9 61.7 66.4 71.2
500 21.0 24.7 42.7 50.6 55.3 60.1 64.8 69.6 74.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 21.8 31.0 36.8 42.6 48.4 54.2 60.0
150 X X 25.2 34.9 40.7 46.5 52.3 58.1 63.9
200 X X 28.5 38.7 44.5 50.4 56.2 62.0 67.8
250 X 21.9 31.9 42.6 48.4 54.2 60.0 65.8 71.7
M12 80 125.4 250.8 103.5 207 300 300 21.0 24.7 35.2 46.5 52.3 58.1 63.9 69.7 75.5 2.0 x Ncbgr
350 21.0 24.7 38.6 50.4 56.2 62.0 67.8 73.6 79.4
400 21.0 24.7 41.9 54.2 60.0 65.8 71.7 77.5 83.3
450 21.0 24.7 45.3 58.1 63.9 69.7 75.5 81.3 87.2
500 21.0 24.7 45.3 62.0 67.8 73.6 79.4 85.2 91.0
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 21.8 31.0 41.1 49.2 55.9 62.6 69.3
150 X X 25.2 34.9 45.5 53.7 60.4 67.1 73.8
200 X X 28.5 38.7 49.8 58.1 64.9 71.6 78.3
250 X 21.9 31.9 42.6 54.1 62.6 69.3 76.0 82.7
M12 80 125.4 250.8 103.5 207 400 300 21.0 24.7 35.2 46.5 58.5 67.1 73.8 80.5 87.2 2.0 x Ncbgr
350 21.0 24.7 38.6 50.4 62.8 71.6 78.3 85.0 91.7
400 21.0 24.7 41.9 54.2 67.1 76.0 82.7 89.5 96.2
450 21.0 24.7 45.3 58.1 71.5 80.5 87.2 93.9 100.6
500 21.0 24.7 45.3 62.0 75.8 85.0 91.7 98.4 105.1
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 21.8 31.0 41.1 52.2 62.5 70.0 77.5
150 X X 25.2 34.9 45.5 56.9 67.5 75.0 82.5
200 X X 28.5 38.7 49.8 61.7 72.5 80.0 87.5
250 X 21.9 31.9 42.6 54.1 66.4 77.5 85.0 92.5
M12 80 125.4 250.8 103.5 207 500 300 21.0 24.7 35.2 46.5 58.5 71.2 82.5 90.0 97.5 2.0 x Ncbgr
350 21.0 24.7 38.6 50.4 62.8 75.9 87.5 95.0 102.5
400 21.0 24.7 41.9 54.2 67.1 80.6 92.5 100.0 107.5
450 21.0 24.7 45.3 58.1 71.5 85.4 97.5 105.0 112.5
500 21.0 24.7 45.3 62.0 75.8 90.1 102.5 110.0 117.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 21.8 31.0 41.1 52.2 64.1 76.7 84.9
150 X X 25.2 34.9 45.5 56.9 69.2 82.2 90.4
200 X X 28.5 38.7 49.8 61.7 74.3 87.6 95.9
250 X 21.9 31.9 42.6 54.1 66.4 79.4 93.1 101.3
M12 80 125.4 250.8 103.5 207 600 300 21.0 24.7 35.2 46.5 58.5 71.2 84.5 98.6 106.8 2.0 x Ncbgr
350 21.0 24.7 38.6 50.4 62.8 75.9 89.7 104.1 112.3
400 21.0 24.7 41.9 54.2 67.1 80.6 94.8 109.6 117.8
450 21.0 24.7 45.3 58.1 71.5 85.4 99.9 115.0 123.3
500 21.0 24.7 45.3 62.0 75.8 90.1 105.0 120.5 128.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X X 21.8 31.0 41.1 52.2 64.1 76.7 90.1
150 X X 25.2 34.9 45.5 56.9 69.2 82.2 95.9
200 X X 28.5 38.7 49.8 61.7 74.3 87.6 101.7
250 X 21.9 31.9 42.6 54.1 66.4 79.4 93.1 107.5
M12 80 125.4 250.8 103.5 207 675 300 21.0 24.7 35.2 46.5 58.5 71.2 84.5 98.6 113.3 2.0 x Ncbgr
350 21.0 24.7 38.6 50.4 62.8 75.9 89.7 104.1 119.1
400 21.0 24.7 41.9 54.2 67.1 80.6 94.8 109.6 124.9
450 21.0 24.7 45.3 58.1 71.5 85.4 99.9 115.0 130.7
500 21.0 24.7 45.3 62.0 75.8 90.1 105.0 120.5 136.5

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12
30 1.22 s s
35 1.32
40 1.41 V V
45 1.50
s
50 1.58 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°
c1 c1 s

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 45
Mechanical Anchoring Systems

2.0 HSL-3 Heavy Duty Sleeve Anchor


Table 15 - Factored resistance for 3 or 6 HSL-3, -G, -B anchors subject to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete 1,2,4,5,6,7 Vcpgr - Pryout
Size hef Spacing, s Vcbgr - Shear Breakout (kN)
Anchor (kN)3 Anchor (kN)
3
Thickness, h Resistance

HSL-3, -B HSL-3-G c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts 3 Bolts 6 Bolts mm mm cmin 150 200 250 300 350 400 450 kN
100 X X 29.2 34.7 40.2 45.6 51.1 56.6
150 X X 32.9 38.3 43.8 49.3 54.8 60.3
200 X X 36.5 42.0 47.5 53.0 58.4 63.9
250 X 34.7 40.2 45.6 51.1 56.6 62.1 67.6
M16 100 227.1 454.2 192.9 385.8 200 300 X 38.3 43.8 49.3 54.8 60.3 65.7 71.2 2.0 x Ncbgr
350 36.7 42.0 47.5 53.0 58.4 63.9 69.4 74.9
400 37.4 45.6 51.1 56.6 62.1 67.6 73.0 78.5
450 37.4 49.3 54.8 60.3 65.7 71.2 76.7 82.2
500 37.4 49.3 58.4 63.9 69.4 74.9 80.3 85.8
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
100 X X 35.8 42.5 49.2 55.9 62.6 69.3
150 X X 40.3 47.0 53.7 60.4 67.1 73.8
200 X X 44.7 51.4 58.1 64.9 71.6 78.3
250 X 36.8 49.2 55.9 62.6 69.3 76.0 82.7
M16 100 227.1 454.2 192.9 385.8 300 300 X 40.7 53.7 60.4 67.1 73.8 80.5 87.2 2.0 x Ncbgr
350 36.7 44.5 58.1 64.9 71.6 78.3 85.0 91.7
400 37.4 48.4 62.6 69.3 76.0 82.7 89.5 96.2
450 37.4 52.3 67.1 73.8 80.5 87.2 93.9 100.6
500 37.4 52.3 71.6 78.3 85.0 91.7 98.4 105.1
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
100 X X 35.8 47.5 56.8 64.6 72.3 80.1
150 X X 40.3 52.5 62.0 69.7 77.5 85.2
200 X X 44.7 57.5 67.1 74.9 82.6 90.4
250 X 36.8 49.2 62.5 72.3 80.1 87.8 95.5
M16 100 227.1 454.2 192.9 385.8 400 300 X 40.7 53.7 67.5 77.5 85.2 93.0 100.7 2.0 x Ncbgr
350 36.7 44.5 58.1 72.5 82.6 90.4 98.1 105.9
400 37.4 48.4 62.6 77.5 87.8 95.5 103.3 111.0
450 37.4 52.3 67.1 82.5 93.0 100.7 108.5 116.2
500 37.4 52.3 71.6 87.5 98.1 105.9 113.6 121.4
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
100 X X 35.8 47.5 60.3 72.2 80.8 89.5
150 X X 40.3 52.5 65.7 78.0 86.6 95.3
200 X X 44.7 57.5 71.2 83.7 92.4 101.0
250 X 36.8 49.2 62.5 76.7 89.5 98.2 106.8
M16 100 227.1 454.2 192.9 385.8 500 300 X 40.7 53.7 67.5 82.2 95.3 103.9 112.6 2.0 x Ncbgr
350 36.7 44.5 58.1 72.5 87.6 101.0 109.7 118.4
400 37.4 48.4 62.6 77.5 93.1 106.8 115.5 124.1
450 37.4 52.3 67.1 82.5 98.6 112.6 121.3 129.9
500 37.4 52.3 71.6 87.5 104.1 118.4 127.0 135.7
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
100 X X 35.8 47.5 60.3 74.0 88.6 98.0
150 X X 40.3 52.5 65.7 79.9 94.9 104.4
200 X X 44.7 57.5 71.2 85.8 101.2 110.7
250 X 36.8 49.2 62.5 76.7 91.7 107.5 117.0
M16 100 227.1 454.2 192.9 385.8 600 300 X 40.7 53.7 67.5 82.2 97.6 113.9 123.3 2.0 x Ncbgr
350 36.7 44.5 58.1 72.5 87.6 103.5 120.2 129.7
400 37.4 48.4 62.6 77.5 93.1 109.5 126.5 136.0
450 37.4 52.3 67.1 82.5 98.6 115.4 132.8 142.3
500 37.4 52.3 71.6 87.5 104.1 121.3 139.2 148.6
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
100 X X 35.8 47.5 60.3 74.0 88.6 104.0
150 X X 40.3 52.5 65.7 79.9 94.9 110.7
200 X X 44.7 57.5 71.2 85.8 101.2 117.4
250 X 36.8 49.2 62.5 76.7 91.7 107.5 124.1
M16 100 227.1 454.2 192.9 385.8 675 300 X 40.7 53.7 67.5 82.2 97.6 113.9 130.8 2.0 x Ncbgr
350 36.7 44.5 58.1 72.5 87.6 103.5 120.2 137.5
400 37.4 48.4 62.6 77.5 93.1 109.5 126.5 144.2
450 37.4 52.3 67.1 82.5 98.6 115.4 132.8 151.0
500 37.4 52.3 71.6 87.5 104.1 121.3 139.2 157.7

Influence of Concrete Strength, fb


f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s s
35 1.32
40 1.41 V V
45 1.50
50 1.58 s
s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°
c1 c1 s

46 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HSL-3 Heavy Duty Sleeve Anchor 2.0


Table 16 - Factored resistance for 3 or 6 HSL-3, -G, -B anchors subject to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete 1,2,4,5,6,7 Vcpgr - Pryout
Size hef Spacing, s Vcbgr - Shear Breakout (kN)
Anchor (kN)3 Anchor (kN)
3
Thickness, h Resistance

HSL-3, -B HSL-3-G c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts 3 Bolts 6 Bolts mm mm cmin 150 200 250 300 350 400 450 kN
150 X X X 46.3 52.9 59.5 66.2 72.8
200 X X 44.1 50.7 57.3 63.9 70.6 77.2
250 X X 48.5 55.1 61.7 68.4 75.0 81.6
300 X 43.9 52.9 59.5 66.2 72.8 79.4 86.0
M20 125 336.3 672.6 282.0 564.0 250 2.0 x Ncbgr
350 41.1 48.1 57.3 63.9 70.6 77.2 83.8 90.4
400 43.0 52.3 61.7 68.4 75.0 81.6 88.2 94.8
450 43.0 56.5 66.2 72.8 79.4 86.0 92.6 99.2
500 43.0 56.5 70.6 77.2 83.8 90.4 97.0 103.6
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 50.7 58.0 65.2 72.5 79.7
200 X X 48.3 55.6 62.8 70.0 77.3 84.5
250 X X 53.1 60.4 67.6 74.9 82.1 89.4
300 X 43.9 58.0 65.2 72.5 79.7 87.0 94.2
M20 125 336.3 672.6 282.0 564.0 300 2.0 x Ncbgr
350 41.1 48.1 62.8 70.0 77.3 84.5 91.8 99.0
400 43.0 52.3 67.6 74.9 82.1 89.4 96.6 103.9
450 43.0 56.5 72.5 79.7 87.0 94.2 101.5 108.7
500 43.0 56.5 77.3 84.5 91.8 99.0 106.3 113.5
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 56.7 66.9 75.3 83.7 92.0
200 X X 48.3 62.1 72.5 80.9 89.3 97.6
250 X X 53.1 67.5 78.1 86.5 94.8 103.2
300 X 43.9 58.0 72.9 83.7 92.0 100.4 108.8
M20 125 336.3 672.6 282.0 564.0 400 2.0 x Ncbgr
350 41.1 48.1 62.8 78.3 89.3 97.6 106.0 114.4
400 43.0 52.3 67.6 83.7 94.8 103.2 111.6 119.9
450 43.0 56.5 72.5 89.1 100.4 108.8 117.1 125.5
500 43.0 56.5 77.3 94.5 106.0 114.4 122.7 131.1
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 56.7 71.0 84.2 93.6 102.9
200 X X 48.3 62.1 76.9 90.4 99.8 109.1
250 X X 53.1 67.5 82.8 96.7 106.0 115.4
300 X 43.9 58.0 72.9 88.8 102.9 112.3 121.6
M20 125 336.3 672.6 282.0 564.0 500 2.0 x Ncbgr
350 41.1 48.1 62.8 78.3 94.7 109.1 118.5 127.9
400 43.0 52.3 67.6 83.7 100.6 115.4 124.7 134.1
450 43.0 56.5 72.5 89.1 106.5 121.6 131.0 140.3
500 43.0 56.5 77.3 94.5 112.4 127.9 137.2 146.6
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 56.7 71.0 86.3 102.5 112.7
200 X X 48.3 62.1 76.9 92.7 109.3 119.6
250 X X 53.1 67.5 82.8 99.1 116.1 126.4
300 X 43.9 58.0 72.9 88.8 105.4 123.0 133.2
M20 125 336.3 672.6 282.0 564.0 600 2.0 x Ncbgr
350 41.1 48.1 62.8 78.3 94.7 111.8 129.8 140.1
400 43.0 52.3 67.6 83.7 100.6 118.2 136.6 146.9
450 43.0 56.5 72.5 89.1 106.5 124.6 143.5 153.7
500 43.0 56.5 77.3 94.5 112.4 131.0 150.3 160.6
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 56.7 71.0 86.3 102.5 119.6
200 X X 48.3 62.1 76.9 92.7 109.3 126.8
250 X X 53.1 67.5 82.8 99.1 116.1 134.1
300 X 43.9 58.0 72.9 88.8 105.4 123.0 141.3
M20 125 336.3 672.6 282.0 564.0 675 2.0 x Ncbgr
350 41.1 48.1 62.8 78.3 94.7 111.8 129.8 148.6
400 43.0 52.3 67.6 83.7 100.6 118.2 136.6 155.8
450 43.0 56.5 72.5 89.1 106.5 124.6 143.5 163.0
500 43.0 56.5 77.3 94.5 112.4 131.0 150.3 170.3

Influence of Concrete Strength, fb


f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s s
35 1.32
40 1.41 V V
45 1.50
50 1.58 s s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°
c1 c1 s

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 47
Mechanical Anchoring Systems

2.0 HSL-3 Heavy Duty Sleeve Anchor


Table 17 - Factored resistance for 3 or 6 HSL-3, -G, -B anchors subject to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Vsgr - Shear Strength of Concrete 1,2,4,5,6,7 Vcpgr - Pryout
Size hef Spacing, s Vcbgr - Shear Breakout (kN)
Anchor (kN)3 Anchor (kN)
3
Thickness, h Resistance

HSL-3, -B HSL-3-G c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts 3 Bolts 6 Bolts mm mm cmin 150 200 250 300 350 400 450 kN
150 X X X 54.2 62.0 69.7 77.5 85.2
200 X X 51.6 59.4 67.1 74.9 82.6 90.4
250 X X 56.8 64.6 72.3 80.1 87.8 95.5
300 47.0 47.0 62.0 69.7 77.5 85.2 93.0 100.7
M24 150 390.9 781.8 N/A N/A 300 2.0 x Ncbgr
350 51.4 51.4 67.1 74.9 82.6 90.4 98.1 105.9
400 55.9 55.9 72.3 80.1 87.8 95.5 103.3 111.0
450 60.4 60.4 77.5 85.2 93.0 100.7 108.5 116.2
500 60.4 60.4 82.6 90.4 98.1 105.9 113.6 121.4
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 60.6 71.6 80.5 89.5 98.4
200 X X 51.6 66.4 77.5 86.5 95.4 104.4
250 X X 56.8 72.2 83.5 92.4 101.4 110.3
300 47.0 47.0 62.0 78.0 89.5 98.4 107.3 116.3
M24 150 390.9 781.8 N/A N/A 400 2.0 x Ncbgr
350 51.4 51.4 67.1 83.7 95.4 104.4 113.3 122.3
400 55.9 55.9 72.3 89.5 101.4 110.3 119.3 128.2
450 60.4 60.4 77.5 95.3 107.3 116.3 125.2 134.2
500 60.4 60.4 82.6 101.0 113.3 122.3 131.2 140.1
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 60.6 75.9 90.0 100.0 110.0
200 X X 51.6 66.4 82.2 96.7 106.7 116.7
250 X X 56.8 72.2 88.6 103.3 113.3 123.3
300 47.0 47.0 62.0 78.0 94.9 110.0 120.0 130.0
M24 150 390.9 781.8 N/A N/A 500 2.0 x Ncbgr
350 51.4 51.4 67.1 83.7 101.2 116.7 126.7 136.7
400 55.9 55.9 72.3 89.5 107.5 123.3 133.3 143.3
450 60.4 60.4 77.5 95.3 113.9 130.0 140.0 150.0
500 60.4 60.4 82.6 101.0 120.2 136.7 146.7 156.7
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 60.6 75.9 92.2 109.6 120.5
200 X X 51.6 66.4 82.2 99.1 116.9 127.8
250 X X 56.8 72.2 88.6 105.9 124.2 135.1
300 47.0 47.0 62.0 78.0 94.9 112.7 131.5 142.4
M24 150 390.9 781.8 N/A N/A 600 2.0 x Ncbgr
350 51.4 51.4 67.1 83.7 101.2 119.6 138.8 149.7
400 55.9 55.9 72.3 89.5 107.5 126.4 146.1 157.0
450 60.4 60.4 77.5 95.3 113.9 133.2 153.4 164.3
500 60.4 60.4 82.6 101.0 120.2 140.1 160.7 171.6
c1 - edge distance (mm)
cmin 150 200 250 300 350 400 450
150 X X X 60.6 75.9 92.2 109.6 127.8
200 X X 51.6 66.4 82.2 99.1 116.9 135.6
250 X X 56.8 72.2 88.6 105.9 124.2 143.3
300 47.0 47.0 62.0 78.0 94.9 112.7 131.5 151.1
M24 150 390.9 781.8 N/A N/A 675 2.0 x Ncbgr
350 51.4 51.4 67.1 83.7 101.2 119.6 138.8 158.8
400 55.9 55.9 72.3 89.5 107.5 126.4 146.1 166.6
450 60.4 60.4 77.5 95.3 113.9 133.2 153.4 174.3
500 60.4 60.4 82.6 101.0 120.2 140.1 160.7 182.0

Influence of Concrete Strength, fb


f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s s
35 1.32
40 1.41 V V
45 1.50
50 1.58 s
s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊΣ°
c1 c1 s

48 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

HSL-3 Heavy Duty Sleeve Anchor 2.0

2.4 Installation Instructions

1. Using the correct diameter metric bit, Ó°Ê,i“œÛiÊ`Àˆˆ˜}Ê`iLÀˆÃÊ܈̅Ê>ÊLœÜœÕÌÊLՏLʜÀÊ


drill hole to minimum required hole depth with compressed air.
or deeper.

3. Using a hammer, tap the anchor through 4. Using a torque wrench, apply the speci-
the part being fastened into the drilled fied installation torque. HSL-3-B does not
hole until the washer is in contact with require use of a torque wrench. Tighten
the fastened part. Do not expand anchor until torque cap shears off.
by hand prior to installation.

2.5 Ordering Information

HSL-3 Bolt Version HSL-3-B Torque Cap HSL-3-G Stud Version


Item No. Description Box Qty Item No. Description Box Qty Item No. Description Box Qty
ÎÇ£ÇÇxÊ Ê-‡ÎÊÊnÉÓäÊ {ä ÎÇ£näÇÊ -‡Î‡ ÊÊ£ÓÉxÊ Óä ÎǣǙÎÊ -‡Î‡ÊÊnÉÓäÊ {ä
ÎÇ£ÇÇÈÊ Ê-‡ÎÊÊnÉ{äÊ {ä ÎÇ£nänÊ -‡Î‡ ÊÊ£ÓÉÓxÊ Óä ÎǣǙÈÊ -‡Î‡ÊÊ£äÉÓäÊ Óä
ÎÇ£ÇÇnÊ Ê-‡ÎÊÊ£äÉÓäÊ Óä ÎÇ£nä™Ê -‡Î‡ ÊÊ£ÓÉxäÊ £ä ÎǣǙ™Ê -‡Î‡ÊÊ£ÓÉÓxÊ Óä
ÎÇ£ÇÇ™Ê Ê-‡ÎÊÊ£äÉ{äÊ Óä ÎÇ£n£äÊ -‡Î‡ ÊÊ£ÈÉ£äÊ £ä ÎÇ£nääÊ -‡Î‡ÊÊ£ÓÉxäÊ £ä
ÎÇ£Çn£Ê Ê-‡ÎÊÊ£ÓÉÓxÊ Óä ÎÇ£n££Ê -‡Î‡ ÊÊ£ÈÉÓxÊ £ä ÎÇ£näÓÊ -‡Î‡ÊÊ£ÈÉÓxÊ £ä
ÎÇ£ÇnÓÊ Ê-‡ÎÊÊ£ÓÉxäÊ Óä ÎÇ£n£{Ê -‡Î‡ ÊÊÓäÉÎäÊ È ÎÇ£näÎÊ -‡Î‡ÊÊ£ÈÉxäÊ £ä
ÎÇ£Çn{Ê Ê-‡ÎÊÊ£ÈÉÓxÊ £ä ÎÇ£n£ÇÊ -‡Î‡ ÊÊÓ{ÉÎäÊ { ÎÇ£näxÊ -‡Î‡ÊÊÓäÉÎäÊ È
ÎÇ£ÇnxÊ Ê-‡ÎÊÊ£ÈÉxäÊ £ä ÎÇ£näÈÊ -‡Î‡ÊÊÓäÉÈäÊ È
ÎÇ£ÇnÇÊ Ê-‡ÎÊÊÓäÉÎäÊ È
ÎÇ£ÇnnÊ Ê-‡ÎÊÊÓäÉÈäÊ È
ÎǣǙäÊ Ê-‡ÎÊÊÓ{ÉÎäÊ {
ÎǣǙ£Ê Ê-‡ÎÊÊÓ{ÉÈäÊ {

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 49
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


ΰ£Ê *Àœ`ÕVÌÊ iÃVÀˆ«Ìˆœ˜ 3.1 Kwik Bolt TZ Product Description
3.2 Material Specifications
/…iÊ܈ŽÊ œÌÊ/<Ê­ ‡/<®ÊˆÃÊ>Ê̜ÀµÕiÊ Product Features
3.3 Technical Data controlled expansion anchor which is UÊ *Àœ`ÕVÌÊ>˜`ʏi˜}̅ʈ`i˜ÌˆvˆV>̈œ˜Ê
3.4 Installation Instructions iëiVˆ>ÞÊÃՈÌi`Ê̜ÊÃiˆÃ“ˆVÊ>˜`ÊVÀ>VŽi`Ê “>ÀŽÃÊv>VˆˆÌ>ÌiʵÕ>ˆÌÞÊVœ˜ÌÀœÊ>vÌiÀÊ
3.5 Ordering Information concrete applications. This anchor line installation.
ˆÃÊ>Û>ˆ>Liʈ˜ÊV>ÀLœ˜ÊÃÌiiÊ܈̅Ê∘VÊ UÊ /…ÀœÕ}…ÊvˆÝÌÕÀiʈ˜ÃÌ>>̈œ˜Ê>˜`Ê
electroplated coating and 304 stainless variable thread lengths improve
steel versions. The anchor diameters productivity and accommodate
Û>ÀˆœÕÃÊL>ÃiÊ«>ÌiÊ̅ˆVŽ˜iÃÃið
À>˜}iÊvÀœ“ÊÎÉnÊ̜ÊÎÉ{ʈ˜V…ʈ˜Ê>ÊÛ>ÀˆiÌÞÊ
of lengths. Applicable base materials UÊ Î£ÈÊ-Ì>ˆ˜iÃÃÊ-ÌiiÊÜi`}iÃÊ«Àœ-
vide superior performance in
include normal-weight concrete,
Impact Section VÀ>VŽi`ÊVœ˜VÀiÌi°
­ œ}Ê*œˆ˜Ì® structural lightweight concrete, and
UÊ ,ˆ`}iÃʜ˜ÊiÝ«>˜Ãˆœ˜ÊÜi`}iÃÊÊ Ê
ˆ}…ÌÜiˆ}…ÌÊVœ˜VÀiÌiʜÛiÀʓiÌ>Ê`iVŽ° provide increased reliability.
Guide Specifications UÊ iV…>˜ˆV>ÊiÝ«>˜Ãˆœ˜Ê>œÜÃÊ
immediate load application.
Nut Torque controlled expansion anchors
UÊ ,>ˆÃi`ʈ“«>VÌÊÃiV̈œ˜Ê­`œ}Ê«œˆ˜Ì®Ê
Washer Å>ÊLiÊ܈ŽÊ œÌÊ/<Ê­ ‡/<®ÊÃÕ««ˆi`Ê prevents thread damage during
by Hilti meeting the description in installation.
,i`Ê i`iÀ>Ê-«iVˆvˆV>̈œ˜Ê‡Ê£™ÓÎ]Ê Installation
Setting Type 4. The anchor bears a length
>ÀŽ ˆ`i˜ÌˆvˆV>̈œ˜Ê“>ÀŽÊi“LœÃÃi`ʈ˜ÌœÊ Drill hole in base material to the
the impact section (dog point) of the appropriate depth using a Hilti carbide
Anchor tipped drill bit. Drive the anchor into
Thread anchor surrounded by four embossed
notches identifying the anchor as a Hilti the hole using a hammer. A minimum
܈ŽÊ œÌÊ/<ʈ˜Ê̅iʈ˜ÃÌ>i`ÊVœ˜`ˆÌˆœ˜°Ê of four threads must be below the
Anchors are manufactured to meet one fastening surface prior to applying
œvÊ̅iÊvœœÜˆ˜}ÊVœ˜`ˆÌˆœ˜Ã\Ê installation torque. Tighten the nut to the
Anchor recommended installation torque.
Body UÊ /…iÊV>ÀLœ˜ÊÃÌiiÊ>˜V…œÀÊLœ`Þ]ʘÕÌ]Ê
and washer have an electroplated
∘VÊVœ>̈˜}ÊVœ˜vœÀ“ˆ˜}Ê̜Ê-/Ê
ÊÈÎÎÊ̜Ê>ʓˆ˜ˆ“Õ“Ê̅ˆVŽ˜iÃÃʜvÊxÊ
Stainless
μm. The stainless steel expansion
Steel
sleeve conforms to AISI 316.
Expansion
Sleeve UÊ -Ì>ˆ˜iÃÃÊÃÌiiÊ>˜V…œÀÊLœ`Þ]ʘÕÌÊ
(Wedges) and washer conform to AISI 304.
Stainless steel expansion sleeve
conforms to AISI 316.

Expansion Cone

Listings/Approvals
ICC-ES (International Code Council)
-,‡£™£ÇÊ
FM (Factory Mutual)
*ˆ«iÊ>˜}iÀÊ
œ“«œ˜i˜ÌÃÊvœÀÊÕ̜“>̈VÊ
-«Àˆ˜ŽiÀÊ-ÞÃÌi“ÃÊ­ÎÉn»Ê‡ÊÎÉ{»®
UL (Underwriters Laboratories)
*ˆ«iÊ>˜}iÀÊ µÕˆ«“i˜ÌÊvœÀʈÀiÊ
*ÀœÌiV̈œ˜Ê-iÀۈViÃÊ­ÎÉn»Ê‡ÊÎÉ{»®

50 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0

3.2 Material Specifications


Carbon steel with electroplated zinc
1

>ÀLœ˜ÊÃÌiiÊ ‡/<Ê>˜V…œÀÃʅ>ÛiÊ̅iÊvœœÜˆ˜}ʓˆ˜ˆ“Õ“ÊLœÌÊvÀ>VÌÕÀiʏœ>`Ã

Anchor Shear Tension


Diameter (in.) (lb) (lb)

Ê ÎÉnÊÊ Ê ÈÇ{{
Ê £ÉÓÊ Ç{£™Ê ££Ó{ä
Ê xÉnÊ ££{ÈxÊ £ÇxÎx
Ê ÎÉ{Ê £ÇxÎxÊ ÓxnxÎ


>ÀLœ˜ÊÃÌiiÊ>˜V…œÀÊVœ“«œ˜i˜ÌÃÊ«>Ìi`ʈ˜Ê>VVœÀ`>˜ViÊ܈̅Ê-/Ê ÊÈÎÎÊ̜Ê>ʓˆ˜ˆ“Õ“Ê̅ˆVŽ˜iÃÃʜvÊx–“°
UÊ ÕÌÃÊVœ˜vœÀ“Ê̜Ê̅iÊÀiµÕˆÀi“i˜ÌÃʜvÊ-/ÊÊxÈÎ]ÊÀ>`iÊ]ÊiÝ°Ê
UÊ 7>ÅiÀÃʓiiÌÊ̅iÊÀiµÕˆÀi“i˜ÌÃʜvÊ-/ÊÊn{{°Ê
UÊ Ý«>˜Ãˆœ˜ÊÏiiÛiÃÊ­Üi`}iîÊ>Àiʓ>˜Õv>VÌÕÀi`ÊvÀœ“Ê-ÊΣÈÊÃÌ>ˆ˜iÃÃÊÃÌii°Ê

Stainless steel
1
UÊ -Ì>ˆ˜iÃÃÊÃÌiiÊ ‡/<Ê>˜V…œÀÃÊ>Àiʓ>`iʜvÊ-ÊÎä{ʓ>ÌiÀˆ>Ê>˜`ʅ>ÛiÊ̅iÊvœœÜˆ˜}ʓˆ˜ˆ“Õ“ÊLœÌÊvÀ>VÌÕÀiʏœ>`Ã

Anchor Shear Tension


Diameter (in.) (lb) (lb)

Ê ÎÉnÊ xäxnÊ Èx£™


Ê £ÉÓÊ nx{ÎÊ £ÓÎÈ{
Ê xÉnÊ £Î™ÎnÊ £™£ä™
Ê ÎÉ{Ê ÓÓ{n£Ê Ó{Çә

UÊ ÕÌÃʓiiÌÊ̅iÊ`ˆ“i˜Ãˆœ˜>ÊÀiµÕˆÀi“i˜ÌÃʜvÊ-/ÊÊx™{°
UÊ 7>ÅiÀÃʓiiÌÊ̅iÊ`ˆ“i˜Ãˆœ˜>ÊÀiµÕˆÀi“i˜ÌÃʜvÊ -Ê £n°ÓÓ°£]Ê/Þ«iÊ]Ê«>ˆ˜°
UÊ Ý«>˜Ãˆœ˜Ê-iiÛiÊ>Àiʓ>`iÊvÀœ“Ê-ÊΣȰ
UÊ Ê˜ÕÌÃÊ>˜`ÊÜ>ÅiÀÃÊ>Àiʓ>`iÊvÀœ“Ê-ÊÎä{ÊÃÌ>ˆ˜iÃÃÊÃÌii°Ê

1 Bolt fracture loads are determined by testing in jig as part of product QC. These loads are not intended for design purposes. See Tables 2 and 3.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 51
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor

3.3 Technical Data


Table 1 — Kwik Bolt TZ Specification Table

SETTING Nominal anchor diameter in.


Symbol Units
INFORMATION 3/8 1/2 5/8 3/4
Anchor O.D. do mm 9.5 12.7 15.9 19.1
Nominal bit
d bitÊ ˆ˜°Ê ÎÉnÊ £ÉÓÊ xÉnÊ ÎÉ{
diameter
Effective min.
h ef mm 51 51 83 79 102 95 121
embedment
Min. hole depth ho mm 67 67 102 95 121 117 146
Ê ˆ˜°Ê̅ˆVŽ˜iÃÃʜvÊÊ
t min mm 6 19 6 9 19 3 41
fixture1
Ê >Ý°Ê̅ˆVŽ˜iÃÃʜvÊÊ
t max mm 57 101 70 143 121 117 92
fixture
Installation torque T inst Nm 34 54 81 149
Min. dia. of hole mm 11.1 14.3 17.5 20.6
dh
Ê ˆ˜ÊvˆÝÌÕÀiÊ Ê ­ˆ˜°®Ê ­ÇÉ£È®Ê ­™É£È®Ê ­££É£È®Ê ­£ÎɣȮ
Available anchor mm 76 95 127 95 114 140 178 121 152 216 254 140 203 254
 anch
Ê i˜}̅ÃÊ Ê ­ˆ˜°®Ê ­Î®Ê ­Î‡ÎÉ{®Ê ­x®Ê ­Î‡ÎÉ{®Ê­{‡£ÉÓ®Ê ­x‡£ÉÓ®Ê ­Ç®Ê ­{‡ÎÉ{®Ê ­È®Ê ­n‡£ÉÓ®Ê ­£ä®Ê ­x‡£ÉÓ®Ê ­n®Ê ­£ä®
Threaded length
 thread mm 22 41 73 41 60 86 178 38 70 133 171 38 102 152
including dog point
Unthreaded length  unthr mm 54 54 83 102
Installation
h nom mm 57 60 92 92 114 111 137
embedment
£Ê /…iʓˆ˜ˆ“Õ“Ê̅ˆVŽ˜iÃÃʜvÊ̅iÊv>ÃÌi˜i`Ê«>ÀÌʈÃÊL>Ãi`ʜ˜ÊÕÃiʜvÊ̅iÊ>˜V…œÀÊ>Ìʓˆ˜ˆ“Õ“Êi“Li`“i˜ÌÊ>˜`ʈÃÊVœ˜ÌÀœi`ÊLÞÊ̅iʏi˜}̅ʜvÊ̅Ài>`°ÊÊ
vÊ>Ê̅ˆ˜˜iÀÊv>ÃÌi˜ˆ˜}Ê̅ˆVŽ˜iÃÃʈÃÊÀiµÕˆÀi`]ʈ˜VÀi>ÃiÊ̅iÊ>˜V…œÀÊi“Li`“i˜ÌÊ̜ÊÃՈ̰

Figure 1 — Kwik Bolt TZ installed

52 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Carbon Steel KB-TZ Design Information (For use with CSA A23.3-04, Annex D)
Design Parameter Symbol Units Nominal anchor diameter Ref.
3/8 1/2 5/8 3/4 A23.3-04
Anchor O.D. do mm 9.5 12.7 15.9 19.1
Effective minimum mm 51 51 83 79 102 95 121
hef,min
Ê i“Li`“i˜ÌÊ`i«Ì…Ê Ê ˆ˜°Ê Ê ÓÊ Ê Ê ÓÊ Ê Ê Î‡£É{Ê Ê Î‡£ÉnÊ Ê {Ê Ê Ê Î‡ÎÉ{Ê Ê {‡ÎÉ{
Ê ˆ˜°Ê“i“LiÀÊ̅ˆVŽ˜iÃÃÊ h min mm 102 127 102 152 152 203 127 152 203 152 203 203
Critical edge distance c ac mm 111 102 140 114 191 152 165 222 171 254 203 229
c a,min mm 64 70 60 92 83 121 105
Min. edge distance
for s ≥ mm 127 146 146 156 149 267 225
s min mm 64 70 60 89 76 127 102
Min. anchor spacing
for c ≥ mm 92 105 89 121 108 241 197
Minimum hole depth
ho mm 67 67 102 98 121 117 146
in concrete
Anchor category 1, 2 or 3 1 D.5.4c
Material resistance
factor for concrete Fc 0.65 8.4.2
Steel embedment material
resistance factor for factor Fs 0.85 8.4.3
reinforcement
Strength reduction
Ê v>V̜ÀÊvœÀÊÌi˜Ãˆœ˜]Ê ,Ê Ê Ê Ê Ê Ê Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊä°näÊÊ Ê Ê Ê Ê Ê Ê Ê °x°{>
steel failure modes
Strength reduction
Ê v>V̜ÀÊvœÀÊÅi>À]ÊÃÌiiÊ ,Ê Ê Ê Ê Ê Ê Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊä°ÇxÊÊ Ê Ê Ê Ê Ê Ê Ê °x°{>
failure modes
Strength reduction
,ÊÊ
œ˜`°ÊÊÊ Ê Ê Ê Ê Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊ£°£xÊÊ Ê Ê Ê Ê Ê Ê Ê °x°{V
factor for tension,
Ê Vœ˜VÀiÌiÊv>ˆÕÀiʓœ`iÃÊ ,ÊÊ
œ˜`°Ê ÊÊ Ê Ê Ê Ê Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊ£°ääÊÊ Ê Ê Ê Ê Ê Ê Ê °x°{V
Strength reduction factor Cond. A 1.15 D.5.4c
Ê vœÀÊÅi>ÀÊVœ˜VÀiÌiÊ ,ÊÊ
Ê v>ˆÕÀiʓœ`iÃÊ ,Ê
œ˜`°Ê ÊÊ Ê Ê Ê Ê Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊ£°ääÊÊ Ê Ê Ê Ê Ê Ê Ê °x°{V
Yield strength of
fyÊÊ *>Ê Ê È™äÊ Ê Ê ÊÊÊÊÊÊÊÊÊÊÊÊxnxÊ Ê Ê Ê Ê xnxÊ Ê Ê Ê Ê xnx
anchor steel
Ultimate strength of
*>Ê Ê nÈÓÊ Ê Ê ÊÊÊÊÊÊÊÊÊÊÊÊÇÎ£Ê Ê Ê Ê Ê ÇÎ£Ê Ê Ê Ê Ê ÇΣ
anchor steel fut
Effective cross-sectional area Ase mm2 33.6 65.0 104.6 152.8
Coefficient for factored
Ê Vœ˜VÀiÌiÊLÀi>ŽœÕÌÊÊ ŽÊÊ Ê Ê Ê Ê Ê Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊÊÊÇÊ Ê Ê Ê Ê Ê Ê Ê Ê °È°Ó°È
resistance in tension
Modification factor for
resistance in tension
#c,N 1.40 D.6.2.6
to account for
Ê Õ˜VÀ>VŽi`ÊVœ˜VÀiÌi
Ê >V̜Ài`Ê-ÌiiÊ,iÈÃÌ>˜ViÊ
NsrÊ ÊŽ ÊÊ Ê £™°ÇÊ Ê Ê ÊÊÊÊÊÊÊÊÊÊÊÎÓ°ÎÊ Ê Ê Ê Ê xÓ°äÊ Ê Ê Ê Ê ÇÈ°äÊ Ê °È°£°Ó
in tension
Ê >V̜Ài`Ê-ÌiiÊ,iÈÃÌ>˜ViÊ
VsrÊÊ Ž ÊÊ Ê £ä°ÓÊ Ê Ê ÊÊÊÊÊÊÊÊÊÊÊ£n°ÓÊ Ê Ê Ê Ê Ó™°™Ê Ê Ê Ê Ê {x°ÓÊ Ê °Ç°£°ÓV
in shear
Ê >V̜Ài`Ê-ÌiiÊ,iÈÃÌ>˜ViÊ
Vsr, seismicÊÊ Ž Ê Ê È°{Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊ£n°ÓÊ Ê Ê Ê Ê Ó™°™Ê Ê Ê Ê Ê {ä°{
in shear, seismic
Ê >V̜Ài`Ê-ÌiiÊ,iÈÃÌ>˜Vi
in shear, concrete on VÃÀ]Ê`iVŽÊÊ Ž Ê Ê È°äÊ Ê Ê n°xÊ Ê Ê £{°äÊ Ê £Î°äÊ Ê £Ç°£Ê Ê ÊÊÊÊÊ œÌÊ*iÀ“ˆÌÌi`
Ê “iÌ>Ê`iVŽ
Ê >V̜Ài`ʫՏœÕÌÊÀiÈÃÌ>˜ViÊ
Ê ˆ˜ÊÓäÊ*>Ê՘VÀ>VŽi`ÊÊ Npr, uncrÊÊ Ž ÊÊ Ê Ç°nÊÊ Ê Ê ÉÊ Ê Ê £Ç°£Ê Ê ÉÊ Ê Ón°{ÊÊ Ê Ê Óx°ÇÊ Ê ÎΰÓÊÊ °È°Î°Ó
concrete
Ê >V̜Ài`ʫՏœÕÌÊÀiÈÃÌ>˜ViÊ
Ê ˆ˜ÊÓäÊ*>ÊVÀ>VŽi`Ê Npr, crÊÊ Ž ÊÊ Ê Ç°£Ê Ê Ê ÉÊ Ê Ê £x°ÎÊ Ê Ê ÉÊ Ê Ê Ê Ê ÉÊ Ê °È°Î°Ó
concrete
Ê >V̜Ài`ʫՏœÕÌÊÀiÈÃÌ>˜ViÊ
Ê ˆ˜ÊÓäÊ*>ÊVÀ>VŽi`ÊVœ˜VÀiÌiÊ N«À]`iVŽÊVÀÊÊ Ž ÊÊ Ê {°xÊ Ê Ê {°xÊ Ê Ê n°£Ê Ê È°ÓÊ Ê £{°{Ê Ê ÊÊÊÊÊÊ œÌÊ*iÀ“ˆÌÌi`Ê °È°Î°Ó
Ê œ˜Ê“iÌ>Ê`iVŽ

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 53
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Stainless Steel KB-RTZ Design Information (For use with CSA A23.3-04, Annex D)
Design Parameter Symbol Units Nominal anchor diameter Ref.
3/8 1/2 5/8 3/4 A23.3-04
Anchor O.D. do mm 9.5 12.7 15.9 19.1
Effective minimum mm 51 51 83 79 102 95 121
hef,min
Ê i“Li`“i˜ÌÊ`i«Ì…Ê Ê ˆ˜°Ê Ê ÓÊ Ê Ê ÓÊ Ê Ê Î‡£É{Ê Ê Î‡£ÉnÊ Ê {Ê Ê Ê Î‡ÎÉ{Ê Ê {‡ÎÉ{
Ê ˆ˜°Ê“i“LiÀÊ̅ˆVŽ˜iÃÃÊ h min mm 102 127 102 152 152 203 127 152 203 152 203 203
Critical edge distance c ac mm 111 98 140 114 191 152 178 225 152 254 178 229
ca,min mm 64 73 54 83 60 108 102
Min. edge distance
for s ≥ mm 127 146 133 140 140 254 216
s min mm 57 73 51 70 60 127 102
Min. anchor spacing
for c ≥ mm 89 114 83 105 108 241 178
Minimum hole depth
ho mm 67 67 102 95 121 117 146
in concrete
Anchor category 1, 2 or 3 1 D.5.4c
Concrete material
resistance factor Fc 0.65 8.4.2
for concrete
Steel embedment
material resistance Fs 0.85 8.4.3
factor for reinforcement
Strength reduction
Ê v>V̜ÀÊvœÀÊÌi˜Ãˆœ˜]Ê ,Ê Ê Ê Ê Ê Ê Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊä°näÊ Ê Ê Ê Ê Ê Ê Ê Ê °x°{>
steel failure modes
Strength reduction
Ê v>V̜ÀÊvœÀÊÅi>À]Ê ,Ê Ê Ê Ê Ê Ê Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊä°ÇxÊ Ê Ê Ê Ê Ê Ê Ê Ê °x°{>
steel failure modes
Strength reduction ,ÊÊ
œ˜`°ÊÊÊ Ê Ê Ê Ê Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊ£°£xÊ Ê Ê Ê Ê Ê Ê Ê Ê °x°{V
factor for tension,
concrete failure modes ,ÊÊ
œ˜`°Ê ÊÊ Ê Ê Ê Ê Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊ£°ääÊ Ê Ê Ê Ê Ê Ê Ê Ê °x°{V
Strength reduction ,ÊÊ
œ˜`°ÊÊÊ Ê Ê Ê Ê Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊ£°£xÊ Ê Ê Ê Ê Ê Ê Ê Ê °x°{V
factor for shear,
concrete failure modes ,ÊÊ
œ˜`°Ê ÊÊ Ê Ê Ê Ê Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊ£°ääÊ Ê Ê Ê Ê Ê Ê Ê Ê °x°{V
Yield strength
fyÊÊ *>Ê Ê ÈÎ{Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊÊÈÎ{ÊÊÊ Ê Ê Ê ÈÎ{Ê Ê Ê Ê Ê xÓx
of anchor steel
Ultimate strength
futÊÊ *>Ê Ê Ç™ÎÊ Ê Ê ÊÊÊÊÊÊÊÊÊÊÊÊǙÎÊÊÊ Ê Ê Ê Ç™ÎÊ Ê Ê Ê Ê Çää
of anchor steel
Effective cross-
Ase mm2 33.6 65.0 104.6 152.8
sectional area
Coefficient for factored
Ê Vœ˜VÀiÌiÊLÀi>ŽœÕÌÊÊ ŽÊÊ Ê Ê ÇÊ Ê Ê £äÊ Ê Ê ÇÊ ÊÊÊÊÊÊÊÊÊÊÊÊÊÊ ÇÊ Ê Ê Ê £äÊÊÊÊÊÊÊÊÊÊÊÊÊÊÇÊ Ê °È°Ó°È
resistance in tension
Modification factor for
resistance in tension
#c,N 1.40 1.00 1.40 1.40 1.00 1.40 D.6.2.6
to account for
Ê Õ˜VÀ>VŽi`ÊVœ˜VÀiÌi
Ê >V̜Ài`Ê-ÌiiÊ,iÈÃÌ>˜ViÊ
NsrÊ ÊŽ ÊÊ Ê £n°£Ê Ê Ê ÊÊÊÊÊÊÊÊÊÊÊÎx°£Ê Ê Ê Ê Ê xÈ°{Ê Ê Ê Ê Ê ÇÓ°ÇÊ Ê °È°£°Ó
in tension
Ê >V̜Ài`Ê-ÌiiÊ,iÈÃÌ>˜ViÊÊ
VsrÊÊ Ž ÊÊ Ê £Î°nÊ Ê Ê ÊÊÊÊÊÊÊÊÊÊÊ£™°xÊ Ê Ê Ê Ê ÎΰÈÊ Ê Ê Ê Ê xÈ°™Ê Ê °Ç°£°ÓV
in shear
Ê >V̜Ài`Ê-ÌiiÊ,iÈÃÌ>˜ViÊ
Vsr, seismicÊÊ Ž Ê Ê n°äÊ Ê Ê ÊÊÊÊÊÊÊÊÊÊÊ£™°xÊ Ê Ê Ê Ê ÎΰÈÊ Ê Ê Ê Ê {£°{
in shear, seismic
Ê >V̜Ài`ʫՏœÕÌÊ
Ê ÀiÈÃÌ>˜Viʈ˜ÊÓäÊ*>Ê Npr, uncrÊÊ Ž ÊÊ Ê n°ÓÊÊ Ê Ê ÉÊ Ê Ê £Ç°™Ê Ê Ê ÉÊ Ê Ê Ê ÉÊ Ê ÎÇ°{ÊÊ °È°Î°Ó
Ê Õ˜VÀ>VŽi`ÊVœ˜VÀiÌi
Ê >V̜Ài`ʫՏœÕÌÊ
Ê ÀiÈÃÌ>˜Viʈ˜ÊÓäÊ*>Ê Npr, crÊÊ Ž ÊÊ Ê Ç°ÎÊ Ê Ê ™°™Ê Ê Ê ÉÊ Ê ÉÊ Ê £n°£Ê Ê Óx°ÓÊ ÊÊÊÊÊÊÊÊÊÊÊ ÉÊ Ê °È°Î°Ó
Ê VÀ>VŽi`ÊVœ˜VÀiÌi

54 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Figure 2 — Interpolation of Minimum Edge Distance and Anchor Spacing
s design c design

h min
c a, min at s ≥

s design
s min at c ≥

h ≥ h min
c design
edge distance c

Table 4 — Mean Axial Stiffness Values (1000 lb/in.) for Kwik Bolt TZ Carbon
and Stainless Steel Anchors in Normal-Weight Concrete1

Concrete condition carbon steel KB-TZ, all diameters stainless steel KB-TZ, all diameters
Ê Õ˜VÀ>VŽi`ÊVœ˜VÀiÌiÊ ÇääÊ £Óä
Ê VÀ>VŽi`ÊVœ˜VÀiÌiÊ xääÊ ™ä

1 Mean values shown. Actual stiffness may vary considerably depending on concrete strength, loading and geometry of application.

Figure 3 — Installation in Concrete over Metal Deck Floor

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 55
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Kwik Bolt TZ Length Identification System

Length ID marking Ê Ê
Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê "Ê *Ê +Ê ,Ê -Ê /Ê 1Ê 6Ê 7
on bolt head
Length of From 11⁄2 2 21⁄2 3 31⁄2 4 41⁄2 5 51⁄2 6 61⁄2 7 71⁄2 8 81⁄2 9 91⁄2 10 11 12 13 14 15
anchor, Up to but
 anch (in.) not 2 21⁄2 3 31⁄2 4 41⁄2 5 51⁄2 6 61⁄2 7 71⁄2 8 81⁄2 9 91⁄2 10 11 12 13 14 15 16
including

Figure 4 — Bolt Head with Length Identification Mark and Kwik Bolt TZ Head Notch Embossment

56 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Notes for Tension Tables (Carbon Steel Only) Notes for Shear Tables (Carbon Steel Only)

£ÊœÀʜ̅iÀÊVœ˜VÀiÌiÊÃÌÀi˜}̅Ã]ʓՏ̈«ÞÊNcbr and Npr by 1 Design strengths in table are for anchors near one edge
corresponding influence of concrete strength factor, fb. only. The values do not apply where the distance to an
edge, measured perpendicular to c1, is less than 1.5c1.
ÓÊœÀÊ-Ì>ˆ˜iÃÃÊ-Ìii]ÊÕÃiÊ ‡,/<ÊÌ>Lið
Shear force is assumed to act perpendicular, towards the
3 Design strengths in the table are based on resistance edge with no eccentricity.
“œ`ˆvˆV>̈œ˜Êv>V̜ÀÊ,]ʜvÊ-iV̈œ˜Ê °x°{°Ê>V̜Ài`ÊÌi˜ÃˆiÊ
ÓÊœÀʜ̅iÀÊVœ˜VÀiÌiÊÃÌÀi˜}̅Ã]ʓՏ̈«ÞÊVcbr by corresponding
load Nf must be computed from the load combinations
influence of concrete strength factor, fb.
referenced in Clause 8.3.2. Design strengths for concrete
LÀi>ŽœÕÌ]ÊNbr, pullout, Npr, and sideface blowout, Nsbr ÎÊœÀÊ-Ì>ˆ˜iÃÃÊ-Ìii]ÊÕÃiÊ ‡,/<ÊÌ>Lið
are based on Condition B. Where supplementary
4 Design strengths in the table are based on resistance
reinforcement is provided to satisfy Condition A, design
“œ`ˆvˆV>̈œ˜Êv>V̜ÀÊ,]ʜvÊ-iV̈œ˜Ê °x°{°Ê>V̜Ài`ÊÅi>ÀÊ
strengths for Nbr and Nsbr may be increased by the ratio
load Vf must be computed from the load combinations
œvÊ, condition A ÊÉÊ, condition B . This increase does not apply to
referenced in Clause 8.3.2. Design strengths for
pullout strength, Npr.
Vœ˜VÀiÌiÊLÀi>ŽœÕÌ]ÊVbr, are based on Condition B. Where
{Ê7…iÀiÊ>˜>ÞÈÃʈ˜`ˆV>ÌiÃÊ̅>ÌÊ̅iÀiÊ܈ÊLiʘœÊVÀ>VŽˆ˜}Ê>ÌÊ supplementary reinforcement is provided to satisfy
service load levels (ft < fr) in the region of the anchor, the Condition A, this design may be increased by the ratio
`iÈ}˜ÊÃÌÀi˜}̅ÃÊvœÀÊVœ˜VÀiÌiÊLÀi>ŽœÕÌʈ˜ÊÌi˜Ãˆœ˜]ÊNbr, may œvÊ, condition AÊÉÊ, condition B . This increase does not apply to
be increased by #c,N. See Section D.6.2.6. pryout capacities, for which condition B is always assumed.

xÊ7…iÀiÊ>˜>ÞÈÃʈ˜`ˆV>ÌiÃÊ̅>ÌÊ̅iÀiÊ܈ÊLiʘœÊVÀ>VŽˆ˜}Ê>ÌÊ xÊ7…iÀiÊ>˜>ÞÈÃʈ˜`ˆV>ÌiÃÊ̅>ÌÊ̅iÀiÊ܈ÊLiʘœÊVÀ>VŽˆ˜}Ê>ÌÊ
service load levels (ft < fr) in the region of the anchor, the service load levels (ft < fr) in the region of the anchor, the
design strengths for concrete pullout in tension, Npr, may be `iÈ}˜ÊÃÌÀi˜}̅ÃÊvœÀÊVœ˜VÀiÌiÊLÀi>ŽœÕÌʈ˜ÊÅi>À]ÊVbr, may be
increased by 40%. See Section D.6.3.6. increased by 40%. See Section D.7.2.7.

ÈÊ/…iÊ`iÈ}˜ÊÃÌÀi˜}̅ÃÊvœÀÊVœ˜VÀiÌiÊLÀi>ŽœÕÌ]ÊVbr, are based


on the shear load being applied perpendicular towards
the edge. If the load is applied parallel to the edge, the
strengths may be increased 100%. See Section D.7.2.1c.

7 Linear interpolation for intermediate values of edge


distance, c1 is permissible.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 57
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 1 - Factored resistance for Single KB-TZ anchor subject to Tensile Loads in Cracked Concrete (f ' c = 20 MPa)

Minimum
Min. Nsr - Tension
Embedment Edge 1,3,4 Npr - Nsbr - Sideface
Size Concrete Strength of Ncbr - Tension Breakout (kN)
Depth, hef Distance Pullout1,5 Blowout
Thickness, h
cmin Anchor2

mm mm mm kN c1 - edge distance (mm) kN kN


cmin 100 150 200 250 300 350 400 450

3/8 (2) 51 127 64 19.7 6.5 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.1 N/A
1/2 (2) 51 152 70 32.3 6.9 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.4 N/A N/A
1/2 (3-1/4) 83 203 60 32.3 9.6 13.1 15.4 15.4 15.4 15.4 15.4 15.4 15.4 15.3 N/A
5/8 (3-1/8) 79 127 92 52.0 11.8 12.6 14.3 14.3 14.3 14.3 14.3 14.3 14.3 N/A N/A
5/8 (4) 102 203 83 52.0 13.9 15.5 20.6 21.0 21.0 21.0 21.0 21.0 21.0 N/A N/A
3/4 (3-3/4) 95 203 121 76.0 16.6 X 18.8 18.8 18.8 18.8 18.8 18.8 18.8 N/A N/A
3/4 (4-3/4) 121 203 105 76.0 18.7 X 23.4 27.1 27.1 27.1 27.1 27.1 27.1 N/A N/A

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22
35 1.32
40 1.41
45 1.50
50 1.58 c1
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

58 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 2 - Factored resistance for 2 KB-TZ anchors subject to Tensile Loads in Cracked Concrete (f'c = 20 MPa)

Nsr - Tension
Spacing, Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Anchor Ncbgr - Tension Breakout of Group1,3,4 (kN)
s Group1,5 of Group
Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
64 100 150 200 250 300 350 400 450
100 X 12.3 12.3 12.3 12.3 12.3 12.3 12.3 12.3
150 12.8 14.7 14.7 14.7 14.7 14.7 14.7 14.7 14.7
200 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
250 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
3/8 (2) 51 127 39.4 300 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.2 N/A
350 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
400 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
450 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
500 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
cmin
70 100 150 200 250 300 350 400 450
100 X 12.3 12.3 12.3 12.3 12.3 12.3 12.3 12.3
150 13.7 14.7 14.7 14.7 14.7 14.7 14.7 14.7 14.7
200 13.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
250 13.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
1/2 (2) 51 152 64.6 300 13.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 N/A N/A
350 13.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
400 13.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
450 13.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
500 13.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
cmin
60 100 150 200 250 300 350 400 450
100 X 18.3 21.6 21.6 21.6 21.6 21.6 21.6 21.6
150 15.4 20.9 24.7 24.7 24.7 24.7 24.7 24.7 24.7
200 17.4 23.5 27.7 27.7 27.7 27.7 27.7 27.7 27.7
250 19.3 26.1 30.8 30.8 30.8 30.8 30.8 30.8 30.8
1/2 (3-1/4) 83 203 64.6 300 19.3 26.1 30.8 30.8 30.8 30.8 30.8 30.8 30.8 30.6 N/A
350 19.3 26.1 30.8 30.8 30.8 30.8 30.8 30.8 30.8
400 19.3 26.1 30.8 30.8 30.8 30.8 30.8 30.8 30.8
450 19.3 26.1 30.8 30.8 30.8 30.8 30.8 30.8 30.8
500 19.3 26.1 30.8 30.8 30.8 30.8 30.8 30.8 30.8
cmin
92 100 150 200 250 300 350 400 450
100 X X 20.3 20.3 20.3 20.3 20.3 20.3 20.3
150 X 20.5 23.3 23.3 23.3 23.3 23.3 23.3 23.3
200 21.8 23.2 26.3 26.3 26.3 26.3 26.3 26.3 26.3
250 23.7 25.1 28.6 28.6 28.6 28.6 28.6 28.6 28.6
5/8 (3-1/8) 79 127 104.0 300 23.7 25.1 28.6 28.6 28.6 28.6 28.6 28.6 28.6 N/A N/A
350 23.7 25.1 28.6 28.6 28.6 28.6 28.6 28.6 28.6
400 23.7 25.1 28.6 28.6 28.6 28.6 28.6 28.6 28.6
450 23.7 25.1 28.6 28.6 28.6 28.6 28.6 28.6 28.6
500 23.7 25.1 28.6 28.6 28.6 28.6 28.6 28.6 28.6
cmin
83 100 150 200 250 300 350 400 450
100 X 20.6 27.4 27.8 27.8 27.8 27.8 27.8 27.8
150 20.8 23.1 30.7 31.2 31.2 31.2 31.2 31.2 31.2
200 23.1 25.7 34.1 34.7 34.7 34.7 34.7 34.7 34.7
250 25.3 28.2 37.5 38.1 38.1 38.1 38.1 38.1 38.1
5/8 (4) 102 203 104.0 300 27.6 30.8 40.9 41.5 41.5 41.5 41.5 41.5 41.5 N/A N/A
350 27.9 31.1 41.3 41.9 41.9 41.9 41.9 41.9 41.9
400 27.9 31.1 41.3 41.9 41.9 41.9 41.9 41.9 41.9
450 27.9 31.1 41.3 41.9 41.9 41.9 41.9 41.9 41.9
500 27.9 31.1 41.3 41.9 41.9 41.9 41.9 41.9 41.9
cmin
121 100 150 200 250 300 350 400 450
100 X X X X X X X X X
150 X X X X 28.8 28.8 28.8 28.8 28.8
200 X X X 32.1 32.1 32.1 32.1 32.1 32.1
250 X X 35.4 35.4 35.4 35.4 35.4 35.4 35.4
3/4 (3-3/4) 95 203 151.9 300 33.3 X 37.7 37.7 37.7 37.7 37.7 37.7 37.7 N/A N/A
350 33.3 X 37.7 37.7 37.7 37.7 37.7 37.7 37.7
400 33.3 X 37.7 37.7 37.7 37.7 37.7 37.7 37.7
450 33.3 X 37.7 37.7 37.7 37.7 37.7 37.7 37.7
500 33.3 X 37.7 37.7 37.7 37.7 37.7 37.7 37.7

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 59
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 2 - Factored resistance for 2 KB-TZ anchors subject to Tensile Loads in Cracked Concrete (f'c = 20 MPa)

Nsr - Tension
Spacing, Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Anchor Ncbgr - Tension Breakout of Group1,3,4 (kN)
s Group1,5 of Group
Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
125 120 150 200 250 300 350 400 450
100 X X X X X X X X X
150 X X X 38.3 38.3 38.3 38.3 38.3 38.3
200 X X 36.4 42.0 42.0 42.0 42.0 42.0 42.0
250 31.5 X 39.6 45.7 45.7 45.7 45.7 45.7 45.7
3/4 (4-3/4) 121 203 151.9 300 34.1 X 42.8 49.5 49.5 49.5 49.5 49.5 49.5 N/A N/A
350 36.7 X 46.1 53.2 53.2 53.2 53.2 53.2 53.2
400 37.3 X 46.9 54.2 54.2 54.2 54.2 54.2 54.2
450 37.3 X 46.9 54.2 54.2 54.2 54.2 54.2 54.2
500 37.3 X 46.9 54.2 54.2 54.2 54.2 54.2 54.2

Notes:
A. For eccentric loading, multiply Ncbr by the modification factor for eccentrically loaded anchor groups, ec,N as per Section D.6.2.4.
B. If anchors are affected by more than one edge distance use formulas to calculate Concrete Resistance

Influence of Concrete Strength, fb

f'c (MPa) fb
20 1.00
25 1.12
s
30 1.22
35 1.32
40 1.41
45 1.50
50 1.58 c1
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

60 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 3 - Factored resistance for 4 KB-TZ anchors subject to Tensile Loads in Cracked Concrete (f'c = 20 MPa)

Nsr - Tension
Spacing, Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Anchor Ncbgr - Tension Breakout of Group1,3,4 (kN)
s Group1,5 of Group
Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
64 100 150 200 250 300 350 400 450
100 X 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3
150 26.5 29.1 29.1 29.1 29.1 29.1 29.1 29.1 29.1
200 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
250 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
3/8 (2) 51 127 78.8 300 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6 28.4 N/A
350 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
400 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
450 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
500 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
cmin
70 100 150 200 250 300 350 400 450
100 X 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3
150 27.7 29.1 29.1 29.1 29.1 29.1 29.1 29.1 29.1
200 28.3 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
250 28.3 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
1/2 (2) 51 152 129.2 300 28.3 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6 N/A N/A
350 28.3 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
400 28.3 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
450 28.3 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
500 28.3 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
cmin
60 100 150 200 250 300 350 400 450
100 X 26.4 30.2 30.2 30.2 30.2 30.2 30.2 30.2
150 28.0 34.9 39.5 39.5 39.5 39.5 39.5 39.5 39.5
200 36.2 44.5 50.0 50.0 50.0 50.0 50.0 50.0 50.0
250 45.2 55.1 61.5 61.5 61.5 61.5 61.5 61.5 61.5
1/2 (3-1/4) 83 203 129.2 300 45.2 55.1 61.5 61.5 61.5 61.5 61.5 61.5 61.5 61.2 N/A
350 45.2 55.1 61.5 61.5 61.5 61.5 61.5 61.5 61.5
400 45.2 55.1 61.5 61.5 61.5 61.5 61.5 61.5 61.5
450 45.2 55.1 61.5 61.5 61.5 61.5 61.5 61.5 61.5
500 45.2 55.1 61.5 61.5 61.5 61.5 61.5 61.5 61.5
cmin
92 100 150 200 250 300 350 400 450
100 X X 28.9 28.9 28.9 28.9 28.9 28.9 28.9
150 X 34.6 38.1 38.1 38.1 38.1 38.1 38.1 38.1
200 42.6 44.3 48.6 48.6 48.6 48.6 48.6 48.6 48.6
250 50.3 52.3 57.2 57.2 57.2 57.2 57.2 57.2 57.2
5/8 (3-1/8) 79 127 208.0 300 50.3 52.3 57.2 57.2 57.2 57.2 57.2 57.2 57.2 N/A N/A
350 50.3 52.3 57.2 57.2 57.2 57.2 57.2 57.2 57.2
400 50.3 52.3 57.2 57.2 57.2 57.2 57.2 57.2 57.2
450 50.3 52.3 57.2 57.2 57.2 57.2 57.2 57.2 57.2
500 50.3 52.3 57.2 57.2 57.2 57.2 57.2 57.2 57.2
cmin
83 100 150 200 250 300 350 400 450
100 X 28.7 36.4 36.9 36.9 36.9 36.9 36.9 36.9
150 34.0 36.9 46.0 46.5 46.5 46.5 46.5 46.5 46.5
200 42.6 46.0 56.6 57.3 57.3 57.3 57.3 57.3 57.3
250 52.2 56.1 68.4 69.2 69.2 69.2 69.2 69.2 69.2
5/8 (4) 102 203 208.0 300 62.7 67.2 81.3 82.2 82.2 82.2 82.2 82.2 82.2 N/A N/A
350 64.1 68.6 82.9 83.8 83.8 83.8 83.8 83.8 83.8
400 64.1 68.6 82.9 83.8 83.8 83.8 83.8 83.8 83.8
450 64.1 68.6 82.9 83.8 83.8 83.8 83.8 83.8 83.8
500 64.1 68.6 82.9 83.8 83.8 83.8 83.8 83.8 83.8
cmin
121 100 150 200 250 300 350 400 450
100 X X X X X X X X X
150 X X X X 43.9 43.9 43.9 43.9 43.9
200 X X X 54.6 54.6 54.6 54.6 54.6 54.6
250 X X 66.4 66.4 66.4 66.4 66.4 66.4 66.4
3/4 (3-3/4) 95 203 303.8 300 69.2 X 75.4 75.4 75.4 75.4 75.4 75.4 75.4 N/A N/A
350 69.2 X 75.4 75.4 75.4 75.4 75.4 75.4 75.4
400 69.2 X 75.4 75.4 75.4 75.4 75.4 75.4 75.4
450 69.2 X 75.4 75.4 75.4 75.4 75.4 75.4 75.4
500 69.2 X 75.4 75.4 75.4 75.4 75.4 75.4 75.4

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 61
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 3 - Factored resistance for 4 KB-TZ anchors subject to Tensile Loads in Cracked Concrete (f'c = 20 MPa)

Nsr - Tension
Spacing, Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Anchor Ncbgr - Tension Breakout of Group1,3,4 (kN)
s Group1,5 of Group
Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
125 120 150 200 250 300 350 400 450
100 X X X X X X X X X
150 X X X 54.1 54.1 54.1 54.1 54.1 54.1
200 X X 58.3 65.1 65.1 65.1 65.1 65.1 65.1
250 59.0 X 69.5 77.2 77.2 77.2 77.2 77.2 77.2
3/4 (4-3/4) 121 203 303.8 300 69.8 X 81.6 90.3 90.3 90.3 90.3 90.3 90.3 N/A N/A
350 81.5 X 94.7 104.5 104.5 104.5 104.5 104.5 104.5
400 84.7 X 98.2 108.3 108.3 108.3 108.3 108.3 108.3
450 84.7 X 98.2 108.3 108.3 108.3 108.3 108.3 108.3
500 84.7 X 98.2 108.3 108.3 108.3 108.3 108.3 108.3

Notes:
A. For eccentric loading, multiply Ncbr by the modification factor for eccentrically loaded anchor groups, ec,N as per Section D.6.2.4.
B. If anchors are affected by more than one edge distance use formulas to calculate Concrete Resistance

Influence of Concrete Strength, fb

f'c (MPa) fb
20 1.00
25 1.12
30 1.22 s
35 1.32
40 1.41
45 1.50
50 1.58
55 1.66 c1 s

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

62 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 4 - Factored resistance for 6 KB-TZ anchors subject to Tensile Loads in Cracked Concrete (f'c = 20 MPa)

Nsr - Tension
Spacing, Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Anchor Ncbgr - Tension Breakout of Group1,3,4 (kN)
s Group1,5 of Group
Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
64 100 150 200 250 300 350 400 450
100 X 28.3 28.3 28.3 28.3 28.3 28.3 28.3 28.3
150 39.6 43.5 43.5 43.5 43.5 43.5 43.5 43.5 43.5
200 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
250 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
3/8 (2) 51 127 118.2 300 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5 42.6 N/A
350 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
400 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
450 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
500 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
cmin
70 100 150 200 250 300 350 400 450
100 X 28.3 28.3 28.3 28.3 28.3 28.3 28.3 28.3
150 41.4 43.5 43.5 43.5 43.5 43.5 43.5 43.5 43.5
200 42.4 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
250 42.4 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
1/2 (2) 51 152 193.9 300 42.4 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5 N/A N/A
350 42.4 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
400 42.4 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
450 42.4 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
500 42.4 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
cmin
60 100 150 200 250 300 350 400 450
100 X 34.0 38.9 38.9 38.9 38.9 38.9 38.9 38.9
150 38.5 48.0 54.4 54.4 54.4 54.4 54.4 54.4 54.4
200 52.3 64.3 72.3 72.3 72.3 72.3 72.3 72.3 72.3
250 67.9 82.6 92.3 92.3 92.3 92.3 92.3 92.3 92.3
1/2 (3-1/4) 83 203 193.9 300 67.9 82.6 92.3 92.3 92.3 92.3 92.3 92.3 92.3 91.8 N/A
350 67.9 82.6 92.3 92.3 92.3 92.3 92.3 92.3 92.3
400 67.9 82.6 92.3 92.3 92.3 92.3 92.3 92.3 92.3
450 67.9 82.6 92.3 92.3 92.3 92.3 92.3 92.3 92.3
500 67.9 82.6 92.3 92.3 92.3 92.3 92.3 92.3 92.3
cmin
92 100 150 200 250 300 350 400 450
100 X X 37.5 37.5 37.5 37.5 37.5 37.5 37.5
150 X 48.0 52.9 52.9 52.9 52.9 52.9 52.9 52.9
200 62.1 64.6 70.8 70.8 70.8 70.8 70.8 70.8 70.8
250 75.5 78.5 85.7 85.7 85.7 85.7 85.7 85.7 85.7
5/8 (3-1/8) 79 127 312.0 300 75.5 78.5 85.7 85.7 85.7 85.7 85.7 85.7 85.7 N/A N/A
350 75.5 78.5 85.7 85.7 85.7 85.7 85.7 85.7 85.7
400 75.5 78.5 85.7 85.7 85.7 85.7 85.7 85.7 85.7
450 75.5 78.5 85.7 85.7 85.7 85.7 85.7 85.7 85.7
500 75.5 78.5 85.7 85.7 85.7 85.7 85.7 85.7 85.7
cmin
83 100 150 200 250 300 350 400 450
100 X 35.8 45.4 46.0 46.0 46.0 46.0 46.0 46.0
150 45.2 49.0 61.1 61.9 61.9 61.9 61.9 61.9 61.9
200 59.5 64.2 79.0 80.0 80.0 80.0 80.0 80.0 80.0
250 75.7 81.3 99.2 100.3 100.3 100.3 100.3 100.3 100.3
5/8 (4) 102 203 312.0 300 93.8 100.5 121.6 122.9 122.9 122.9 122.9 122.9 122.9 N/A N/A
350 96.1 102.9 124.4 125.8 125.8 125.8 125.8 125.8 125.8
400 96.1 102.9 124.4 125.8 125.8 125.8 125.8 125.8 125.8
450 96.1 102.9 124.4 125.8 125.8 125.8 125.8 125.8 125.8
500 96.1 102.9 124.4 125.8 125.8 125.8 125.8 125.8 125.8
cmin
121 100 150 200 250 300 350 400 450
100 X X X X X X X X X
150 X X X X 59.0 59.0 59.0 59.0 59.0
200 X X X 77.1 77.1 77.1 77.1 77.1 77.1
250 X X 97.4 97.4 97.4 97.4 97.4 97.4 97.4
3/4 (3-3/4) 95 203 455.7 300 103.9 X 113.0 113.0 113.0 113.0 113.0 113.0 113.0 N/A N/A
350 103.9 X 113.0 113.0 113.0 113.0 113.0 113.0 113.0
400 103.9 X 113.0 113.0 113.0 113.0 113.0 113.0 113.0
450 103.9 X 113.0 113.0 113.0 113.0 113.0 113.0 113.0
500 103.9 X 113.0 113.0 113.0 113.0 113.0 113.0 113.0

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 63
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 4 - Factored resistance for 6 KB-TZ anchors subject to Tensile Loads in Cracked Concrete (f'c = 20 MPa)

Nsr - Tension
Spacing, Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Anchor Ncbgr - Tension Breakout of Group1,3,4 (kN)
s Group1,5 of Group
Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
125 120 150 200 250 300 350 400 450
100 X X X X X X X X X
150 X X X 69.9 69.9 69.9 69.9 69.9 69.9
200 X X 79.0 88.3 88.3 88.3 88.3 88.3 88.3
250 83.1 X 97.8 108.7 108.7 108.7 108.7 108.7 108.7
3/4 (4-3/4) 121 203 455.7 300 101.4 X 118.5 131.2 131.2 131.2 131.2 131.2 131.2 N/A N/A
350 121.5 X 141.1 155.8 155.8 155.8 155.8 155.8 155.8
400 127.0 X 147.4 162.5 162.5 162.5 162.5 162.5 162.5
450 127.0 X 147.4 162.5 162.5 162.5 162.5 162.5 162.5
500 127.0 X 147.4 162.5 162.5 162.5 162.5 162.5 162.5

Notes:
A. For eccentric loading, multiply Ncbr by the modification factor for eccentrically loaded anchor groups, ec,N as per Section D.6.2.4.
B. If anchors are affected by more than one edge distance use formulas to calculate Concrete Resistance

Influence of Concrete Strength, fb

f'c (MPa) fb
20 1.00
25 1.12
30 1.22 s
35 1.32
40 1.41
45 1.50
50 1.58 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

c1 s

64 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 5 - Factored resistance for Single KB-TZ anchor subject to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsr - Shear
Concrete Vcpr - Pryout
Size hef Strength of Vcbr - Shear Breakout (kN)1,2,4,5,6,7
Thickness, h Resistance
Anchor3
c1 - edge distance (mm) kcp X Ncbr
mm kN mm cmin 100 150 200 250 300 350 400 450 kN
127 3.1 5.5 8.2 11.0 13.7 16.5 19.2 22.0 24.7
200 3.1 6.0 10.3 13.8 17.2 20.7 24.1 27.6 31.0
300 3.1 6.0 11.0 16.9 21.1 25.3 29.5 33.8 38.0
3/8 (2) 51 10.2 400 3.1 6.0 11.0 16.9 23.6 29.2 34.1 39.0 43.9 1.0 x Ncbr
500 3.1 6.0 11.0 16.9 23.6 31.0 38.1 43.6 49.0
600 3.1 6.0 11.0 16.9 23.6 31.0 39.1 47.8 53.7
675 3.1 6.0 11.0 16.9 23.6 31.0 39.1 47.8 57.0
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
152 4.0 6.9 10.4 13.9 17.4 20.8 24.3 27.8 31.3
200 4.0 6.9 12.0 15.9 19.9 23.9 27.9 31.9 35.9
203 4.0 6.9 12.0 16.1 20.1 24.1 28.1 32.1 36.1
300 4.0 6.9 12.7 19.5 24.4 29.3 34.2 39.0 43.9
1/2 (2) 51 18.2 1.0 x Ncbr
400 4.0 6.9 12.7 19.5 27.3 33.8 39.4 45.1 50.7
500 4.0 6.9 12.7 19.5 27.3 35.9 44.1 50.4 56.7
600 4.0 6.9 12.7 19.5 27.3 35.9 45.2 55.2 62.1
675 4.0 6.9 12.7 19.5 27.3 35.9 45.2 55.2 65.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
203 3.2 6.9 12.0 16.1 20.1 24.1 28.1 32.1 36.1
300 3.2 6.9 12.7 19.5 24.4 29.3 34.2 39.0 43.9
400 3.2 6.9 12.7 19.5 27.3 33.8 39.4 45.1 50.7
1/2 (3-1/4) 83 18.2 2.0 x Ncbr
500 3.2 6.9 12.7 19.5 27.3 35.9 44.1 50.4 56.7
600 3.2 6.9 12.7 19.5 27.3 35.9 45.2 55.2 62.1
675 3.2 6.9 12.7 19.5 27.3 35.9 45.2 55.2 65.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
127 6.5 7.1 10.7 14.2 17.8 21.3 24.9 28.4 32.0
203 6.8 7.7 13.5 18.0 22.5 27.0 31.4 35.9 40.4
300 6.8 7.7 14.2 21.8 27.3 32.8 38.2 43.7 49.1
5/8 (3-1/8) 79 29.9 400 6.8 7.7 14.2 21.8 30.5 37.8 44.1 50.4 56.7 2.0 x Ncbr
500 6.8 7.7 14.2 21.8 30.5 40.1 49.3 56.4 63.4
600 6.8 7.7 14.2 21.8 30.5 40.1 50.6 61.8 69.5
675 6.8 7.7 14.2 21.8 30.5 40.1 50.6 61.8 73.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
203 5.8 7.7 13.5 18.0 22.5 27.0 31.4 35.9 40.4
300 5.8 7.7 14.2 21.8 27.3 32.8 38.2 43.7 49.1
400 5.8 7.7 14.2 21.8 30.5 37.8 44.1 50.4 56.7 2.0 x Ncbr
5/8 (4) 102 29.9
500 5.8 7.7 14.2 21.8 30.5 40.1 49.3 56.4 63.4
600 5.8 7.7 14.2 21.8 30.5 40.1 50.6 61.8 69.5
675 5.8 7.7 14.2 21.8 30.5 40.1 50.6 61.8 73.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
203 11.3 X 14.8 19.7 24.6 29.5 34.5 39.4 44.3
300 11.3 X 15.5 23.9 29.9 35.9 41.9 47.9 53.9
400 11.3 X 15.5 23.9 33.5 41.5 48.4 55.3 62.2 2.0 x Ncbr
3/4 (3-3/4) 95 45.2
500 11.3 X 15.5 23.9 33.5 44.0 54.1 61.8 69.5
600 11.3 X 15.5 23.9 33.5 44.0 55.4 67.7 76.2
675 11.3 X 15.5 23.9 33.5 44.0 55.4 67.7 80.8

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 65
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 5 - Factored resistance for Single KB-TZ anchor subject to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsr - Shear
Concrete 1,2,4,5,6,7 Vcpr - Pryout
Size hef Strength of Vcbr - Shear Breakout (kN)
Thickness, h Resistance
Anchor3
c1 - edge distance (mm) kcp X Ncbr
mm kN mm cmin 100 150 200 250 300 350 400 450 kN
203 9.1 X 14.8 19.7 24.6 29.5 34.5 39.4 44.3
300 9.1 X 15.5 23.9 29.9 35.9 41.9 47.9 53.9
400 9.1 X 15.5 23.9 33.5 41.5 48.4 55.3 62.2 2.0 x Ncbr
3/4 (4-3/4) 121 45.2
500 9.1 X 15.5 23.9 33.5 44.0 54.1 61.8 69.5
600 9.1 X 15.5 23.9 33.5 44.0 55.4 67.7 76.2
675 9.1 X 15.5 23.9 33.5 44.0 55.4 67.7 80.8

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12 V
30 1.22
35 1.32
40 1.41
45 1.50
50 1.58 c1
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

66 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 6 - Factored resistance for 2 or 4 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 7.3 10.1 12.8 15.6 18.3 21.1 23.8 26.5
150 5.4 8.2 11.0 13.7 16.5 19.2 22.0 24.7 27.5
200 6.1 9.2 11.9 14.6 17.4 20.1 22.9 25.6 28.4
250 6.1 10.1 12.8 15.6 18.3 21.1 23.8 26.5 29.3
3/8 (2) 51 20.4 40.8 127 300 6.1 11.0 13.7 16.5 19.2 22.0 24.7 27.5 30.2 1.0 x Ncbgr
350 6.1 11.0 14.6 17.4 20.1 22.9 25.6 28.4 31.1
400 6.1 11.0 15.6 18.3 21.1 23.8 26.5 29.3 32.0
450 6.1 11.0 16.5 19.2 22.0 24.7 27.5 30.2 33.0
500 6.1 11.0 16.5 20.1 22.9 25.6 28.4 31.1 33.9
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 8.0 12.6 16.1 19.5 23.0 26.4 29.9 33.3
150 5.4 9.0 13.8 17.2 20.7 24.1 27.6 31.0 34.5
200 6.1 9.9 14.9 18.4 21.8 25.3 28.7 32.2 35.6
250 6.1 10.9 16.1 19.5 23.0 26.4 29.9 33.3 36.8
3/8 (2) 51 20.4 40.8 200 300 6.1 11.9 17.2 20.7 24.1 27.6 31.0 34.5 37.9 1.0 x Ncbgr
350 6.1 11.9 18.4 21.8 25.3 28.7 32.2 35.6 39.1
400 6.1 11.9 19.5 23.0 26.4 29.9 33.3 36.8 40.2
450 6.1 11.9 20.7 24.1 27.6 31.0 34.5 37.9 41.4
500 6.1 11.9 20.7 25.3 28.7 32.2 35.6 39.1 42.5
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 8.0 13.4 19.7 23.9 28.1 32.4 36.6 40.8
150 5.4 9.0 14.6 21.1 25.3 29.5 33.8 38.0 42.2
200 6.1 9.9 15.8 22.5 26.7 31.0 35.2 39.4 43.6
250 6.1 10.9 17.1 23.9 28.1 32.4 36.6 40.8 45.0
3/8 (2) 51 20.4 40.8 300 300 6.1 11.9 18.3 25.3 29.5 33.8 38.0 42.2 46.4 1.0 x Ncbgr
350 6.1 11.9 19.5 26.7 31.0 35.2 39.4 43.6 47.8
400 6.1 11.9 20.7 28.1 32.4 36.6 40.8 45.0 49.2
450 6.1 11.9 21.9 29.5 33.8 38.0 42.2 46.4 50.7
500 6.1 11.9 21.9 31.0 35.2 39.4 43.6 47.8 52.1
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 8.0 13.4 19.7 26.7 32.5 37.4 42.2 47.1
150 5.4 9.0 14.6 21.1 28.3 34.1 39.0 43.9 48.7
200 6.1 9.9 15.8 22.5 29.9 35.7 40.6 45.5 50.4
250 6.1 10.9 17.1 23.9 31.5 37.4 42.2 47.1 52.0
3/8 (2) 51 20.4 40.8 400 300 6.1 11.9 18.3 25.3 33.0 39.0 43.9 48.7 53.6 1.0 x Ncbgr
350 6.1 11.9 19.5 26.7 34.6 40.6 45.5 50.4 55.2
400 6.1 11.9 20.7 28.1 36.2 42.2 47.1 52.0 56.9
450 6.1 11.9 21.9 29.5 37.8 43.9 48.7 53.6 58.5
500 6.1 11.9 21.9 31.0 39.3 45.5 50.4 55.2 60.1
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 8.0 13.4 19.7 26.7 34.5 41.8 47.2 52.7
150 5.4 9.0 14.6 21.1 28.3 36.2 43.6 49.0 54.5
200 6.1 9.9 15.8 22.5 29.9 37.9 45.4 50.9 56.3
250 6.1 10.9 17.1 23.9 31.5 39.6 47.2 52.7 58.1
3/8 (2) 51 20.4 40.8 500 300 6.1 11.9 18.3 25.3 33.0 41.4 49.0 54.5 59.9 1.0 x Ncbgr
350 6.1 11.9 19.5 26.7 34.6 43.1 50.9 56.3 61.8
400 6.1 11.9 20.7 28.1 36.2 44.8 52.7 58.1 63.6
450 6.1 11.9 21.9 29.5 37.8 46.5 54.5 59.9 65.4
500 6.1 11.9 21.9 31.0 39.3 48.2 56.3 61.8 67.2
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 8.0 13.4 19.7 26.7 34.5 42.8 51.7 57.7
150 5.4 9.0 14.6 21.1 28.3 36.2 44.7 53.7 59.7
200 6.1 9.9 15.8 22.5 29.9 37.9 46.5 55.7 61.7
250 6.1 10.9 17.1 23.9 31.5 39.6 48.4 57.7 63.7
3/8 (2) 51 20.4 40.8 600 300 6.1 11.9 18.3 25.3 33.0 41.4 50.3 59.7 65.7 1.0 x Ncbgr
350 6.1 11.9 19.5 26.7 34.6 43.1 52.1 61.7 67.7
400 6.1 11.9 20.7 28.1 36.2 44.8 54.0 63.7 69.6
450 6.1 11.9 21.9 29.5 37.8 46.5 55.8 65.7 71.6
500 6.1 11.9 21.9 31.0 39.3 48.2 57.7 67.7 73.6

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 67
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 6 - Factored resistance for 2 or 4 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 8.0 13.4 19.7 26.7 34.5 42.8 51.7 61.2
150 5.4 9.0 14.6 21.1 28.3 36.2 44.7 53.7 63.3
200 6.1 9.9 15.8 22.5 29.9 37.9 46.5 55.7 65.4
250 6.1 10.9 17.1 23.9 31.5 39.6 48.4 57.7 67.5
3/8 (2) 51 20.4 40.8 675 300 6.1 11.9 18.3 25.3 33.0 41.4 50.3 59.7 69.6 1.0 x Ncbgr
350 6.1 11.9 19.5 26.7 34.6 43.1 52.1 61.7 71.8
400 6.1 11.9 20.7 28.1 36.2 44.8 54.0 63.7 73.9
450 6.1 11.9 21.9 29.5 37.8 46.5 55.8 65.7 76.0
500 6.1 11.9 21.9 31.0 39.3 48.2 57.7 67.7 78.1

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

68 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 7 - Factored resistance for 2 or 4 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 9.2 12.7 16.2 19.7 23.2 26.6 30.1 33.6
150 6.9 10.4 13.9 17.4 20.8 24.3 27.8 31.3 34.7
200 7.9 11.5 15.1 18.5 22.0 25.5 28.9 32.4 35.9
250 8.1 12.7 16.2 19.7 23.2 26.6 30.1 33.6 37.1
1/2 (2) 51 36.4 72.8 152 300 8.1 13.8 17.4 20.8 24.3 27.8 31.3 34.7 38.2 1.0 x Ncbgr
350 8.1 13.8 18.5 22.0 25.5 28.9 32.4 35.9 39.4
400 8.1 13.8 19.7 23.2 26.6 30.1 33.6 37.1 40.5
450 8.1 13.8 20.8 24.3 27.8 31.3 34.7 38.2 41.7
500 8.1 13.8 20.8 25.5 28.9 32.4 35.9 39.4 42.8
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.2 14.6 18.6 22.6 26.6 30.5 34.5 38.5
150 6.9 10.4 15.9 19.9 23.9 27.9 31.9 35.9 39.8
200 7.9 11.5 17.3 21.3 25.2 29.2 33.2 37.2 41.2
250 8.1 12.7 18.6 22.6 26.6 30.5 34.5 38.5 42.5
1/2 (2) 51 36.4 72.8 200 300 8.1 13.8 19.9 23.9 27.9 31.9 35.9 39.8 43.8 1.0 x Ncbgr
350 8.1 13.8 21.3 25.2 29.2 33.2 37.2 41.2 45.2
400 8.1 13.8 22.6 26.6 30.5 34.5 38.5 42.5 46.5
450 8.1 13.8 23.9 27.9 31.9 35.9 39.8 43.8 47.8
500 8.1 13.8 23.9 29.2 33.2 37.2 41.2 45.2 49.1
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 27.7 32.5 37.4 42.3 47.2
150 6.9 10.4 16.9 24.4 29.3 34.2 39.0 43.9 48.8
200 7.9 11.5 18.3 26.0 30.9 35.8 40.7 45.5 50.4
250 8.1 12.7 19.7 27.7 32.5 37.4 42.3 47.2 52.1
1/2 (2) 51 36.4 72.8 300 300 8.1 13.8 21.1 29.3 34.2 39.0 43.9 48.8 53.7 1.0 x Ncbgr
350 8.1 13.8 22.5 30.9 35.8 40.7 45.5 50.4 55.3
400 8.1 13.8 24.0 32.5 37.4 42.3 47.2 52.1 56.9
450 8.1 13.8 25.4 34.2 39.0 43.9 48.8 53.7 58.6
500 8.1 13.8 25.4 35.8 40.7 45.5 50.4 55.3 60.2
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 30.9 37.6 43.2 48.8 54.5
150 6.9 10.4 16.9 24.4 32.7 39.4 45.1 50.7 56.4
200 7.9 11.5 18.3 26.0 34.6 41.3 47.0 52.6 58.2
250 8.1 12.7 19.7 27.7 36.4 43.2 48.8 54.5 60.1
1/2 (2) 51 36.4 72.8 400 300 8.1 13.8 21.1 29.3 38.2 45.1 50.7 56.4 62.0 1.0 x Ncbgr
350 8.1 13.8 22.5 30.9 40.0 47.0 52.6 58.2 63.9
400 8.1 13.8 24.0 32.5 41.8 48.8 54.5 60.1 65.7
450 8.1 13.8 25.4 34.2 43.7 50.7 56.4 62.0 67.6
500 8.1 13.8 25.4 35.8 45.5 52.6 58.2 63.9 69.5
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 30.9 39.8 48.3 54.6 60.9
150 6.9 10.4 16.9 24.4 32.7 41.8 50.4 56.7 63.0
200 7.9 11.5 18.3 26.0 34.6 43.8 52.5 58.8 65.1
250 8.1 12.7 19.7 27.7 36.4 45.8 54.6 60.9 67.2
1/2 (2) 51 36.4 72.8 500 300 8.1 13.8 21.1 29.3 38.2 47.8 56.7 63.0 69.3 1.0 x Ncbgr
350 8.1 13.8 22.5 30.9 40.0 49.8 58.8 65.1 71.4
400 8.1 13.8 24.0 32.5 41.8 51.8 60.9 67.2 73.5
450 8.1 13.8 25.4 34.2 43.7 53.8 63.0 69.3 75.6
500 8.1 13.8 25.4 35.8 45.5 55.8 65.1 71.4 77.7
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 30.9 39.8 49.5 59.8 66.7
150 6.9 10.4 16.9 24.4 32.7 41.8 51.6 62.1 69.0
200 7.9 11.5 18.3 26.0 34.6 43.8 53.8 64.4 71.3
250 8.1 12.7 19.7 27.7 36.4 45.8 56.0 66.7 73.6
1/2 (2) 51 36.4 72.8 600 300 8.1 13.8 21.1 29.3 38.2 47.8 58.1 69.0 75.9 1.0 x Ncbgr
350 8.1 13.8 22.5 30.9 40.0 49.8 60.3 71.3 78.2
400 8.1 13.8 24.0 32.5 41.8 51.8 62.4 73.6 80.5
450 8.1 13.8 25.4 34.2 43.7 53.8 64.6 75.9 82.8
500 8.1 13.8 25.4 35.8 45.5 55.8 66.7 78.2 85.1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 69
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 7 - Factored resistance for 2 or 4 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f'c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 9.2 15.5 22.8 30.9 39.8 49.5 59.8 70.8
150 6.9 10.4 16.9 24.4 32.7 41.8 51.6 62.1 73.2
200 7.9 11.5 18.3 26.0 34.6 43.8 53.8 64.4 75.6
250 8.1 12.7 19.7 27.7 36.4 45.8 56.0 66.7 78.1
1/2 (2) 51 36.4 72.8 675 300 8.1 13.8 21.1 29.3 38.2 47.8 58.1 69.0 80.5 1.0 x Ncbgr
350 8.1 13.8 22.5 30.9 40.0 49.8 60.3 71.3 83.0
400 8.1 13.8 24.0 32.5 41.8 51.8 62.4 73.6 85.4
450 8.1 13.8 25.4 34.2 43.7 53.8 64.6 75.9 87.8
500 8.1 13.8 25.4 35.8 45.5 55.8 66.7 78.2 90.3

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

70 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 8 - Factored resistance for 2 or 4 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 9.2 14.7 18.7 22.7 26.8 30.8 34.8 38.8
150 5.9 10.4 16.1 20.1 24.1 28.1 32.1 36.1 40.1
200 6.4 11.5 17.4 21.4 25.4 29.4 33.5 37.5 41.5
250 6.4 12.7 18.7 22.7 26.8 30.8 34.8 38.8 42.8
1/2 (3-1/4) 83 36.4 72.8 203 300 6.4 13.8 20.1 24.1 28.1 32.1 36.1 40.1 44.2 2.0 x Ncbgr
350 6.4 13.8 21.4 25.4 29.4 33.5 37.5 41.5 45.5
400 6.4 13.8 22.7 26.8 30.8 34.8 38.8 42.8 46.8
450 6.4 13.8 24.1 28.1 32.1 36.1 40.1 44.2 48.2
500 6.4 13.8 24.1 29.4 33.5 37.5 41.5 45.5 49.5
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 27.7 32.5 37.4 42.3 47.2
150 5.9 10.4 16.9 24.4 29.3 34.2 39.0 43.9 48.8
200 6.4 11.5 18.3 26.0 30.9 35.8 40.7 45.5 50.4
250 6.4 12.7 19.7 27.7 32.5 37.4 42.3 47.2 52.1
1/2 (3-1/4) 83 36.4 72.8 300 300 6.4 13.8 21.1 29.3 34.2 39.0 43.9 48.8 53.7 2.0 x Ncbgr
350 6.4 13.8 22.5 30.9 35.8 40.7 45.5 50.4 55.3
400 6.4 13.8 24.0 32.5 37.4 42.3 47.2 52.1 56.9
450 6.4 13.8 25.4 34.2 39.0 43.9 48.8 53.7 58.6
500 6.4 13.8 25.4 35.8 40.7 45.5 50.4 55.3 60.2
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 30.9 37.6 43.2 48.8 54.5
150 5.9 10.4 16.9 24.4 32.7 39.4 45.1 50.7 56.4
200 6.4 11.5 18.3 26.0 34.6 41.3 47.0 52.6 58.2
250 6.4 12.7 19.7 27.7 36.4 43.2 48.8 54.5 60.1
1/2 (3-1/4) 83 36.4 72.8 400 300 6.4 13.8 21.1 29.3 38.2 45.1 50.7 56.4 62.0 2.0 x Ncbgr
350 6.4 13.8 22.5 30.9 40.0 47.0 52.6 58.2 63.9
400 6.4 13.8 24.0 32.5 41.8 48.8 54.5 60.1 65.7
450 6.4 13.8 25.4 34.2 43.7 50.7 56.4 62.0 67.6
500 6.4 13.8 25.4 35.8 45.5 52.6 58.2 63.9 69.5
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 30.9 39.8 48.3 54.6 60.9
150 5.9 10.4 16.9 24.4 32.7 41.8 50.4 56.7 63.0
200 6.4 11.5 18.3 26.0 34.6 43.8 52.5 58.8 65.1
250 6.4 12.7 19.7 27.7 36.4 45.8 54.6 60.9 67.2
1/2 (3-1/4) 83 36.4 72.8 500 300 6.4 13.8 21.1 29.3 38.2 47.8 56.7 63.0 69.3 2.0 x Ncbgr
350 6.4 13.8 22.5 30.9 40.0 49.8 58.8 65.1 71.4
400 6.4 13.8 24.0 32.5 41.8 51.8 60.9 67.2 73.5
450 6.4 13.8 25.4 34.2 43.7 53.8 63.0 69.3 75.6
500 6.4 13.8 25.4 35.8 45.5 55.8 65.1 71.4 77.7
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 30.9 39.8 49.5 59.8 66.7
150 5.9 10.4 16.9 24.4 32.7 41.8 51.6 62.1 69.0
200 6.4 11.5 18.3 26.0 34.6 43.8 53.8 64.4 71.3
250 6.4 12.7 19.7 27.7 36.4 45.8 56.0 66.7 73.6
1/2 (3-1/4) 83 36.4 72.8 600 300 6.4 13.8 21.1 29.3 38.2 47.8 58.1 69.0 75.9 2.0 x Ncbgr
350 6.4 13.8 22.5 30.9 40.0 49.8 60.3 71.3 78.2
400 6.4 13.8 24.0 32.5 41.8 51.8 62.4 73.6 80.5
450 6.4 13.8 25.4 34.2 43.7 53.8 64.6 75.9 82.8
500 6.4 13.8 25.4 35.8 45.5 55.8 66.7 78.2 85.1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 71
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 8 - Factored resistance for 2 or 4 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 9.2 15.5 22.8 30.9 39.8 49.5 59.8 70.8
150 5.9 10.4 16.9 24.4 32.7 41.8 51.6 62.1 73.2
200 6.4 11.5 18.3 26.0 34.6 43.8 53.8 64.4 75.6
250 6.4 12.7 19.7 27.7 36.4 45.8 56.0 66.7 78.1
1/2 (3-1/4) 83 36.4 72.8 675 300 6.4 13.8 21.1 29.3 38.2 47.8 58.1 69.0 80.5 2.0 x Ncbgr
350 6.4 13.8 22.5 30.9 40.0 49.8 60.3 71.3 83.0
400 6.4 13.8 24.0 32.5 41.8 51.8 62.4 73.6 85.4
450 6.4 13.8 25.4 34.2 43.7 53.8 64.6 75.9 87.8
500 6.4 13.8 25.4 35.8 45.5 55.8 66.7 78.2 90.3

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

72 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 9 - Factored resistance for 2 or 4 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X X 13.0 16.6 20.1 23.7 27.2 30.8 34.3
150 X 10.7 14.2 17.8 21.3 24.9 28.4 32.0 35.5
200 11.3 11.8 15.4 18.9 22.5 26.1 29.6 33.2 36.7
250 12.5 13.0 16.6 20.1 23.7 27.2 30.8 34.3 37.9
5/8 (3-1/8) 79 59.8 119.6 127 300 13.1 14.2 17.8 21.3 24.9 28.4 32.0 35.5 39.1 2.0 x Ncbgr
350 13.1 14.2 18.9 22.5 26.1 29.6 33.2 36.7 40.3
400 13.1 14.2 20.1 23.7 27.2 30.8 34.3 37.9 41.5
450 13.1 14.2 21.3 24.9 28.4 32.0 35.5 39.1 42.6
500 13.1 14.2 21.3 26.1 29.6 33.2 36.7 40.3 43.8
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X X 16.3 20.8 25.3 29.7 34.2 38.6 43.1
150 X 11.6 17.8 22.3 26.8 31.2 35.7 40.1 44.6
200 11.8 12.9 19.3 23.8 28.2 32.7 37.2 41.6 46.1
250 13.0 14.2 20.8 25.3 29.7 34.2 38.6 43.1 47.6
5/8 (3-1/8) 79 59.8 119.6 200 300 13.6 15.4 22.3 26.8 31.2 35.7 40.1 44.6 49.0 2.0 x Ncbgr
350 13.6 15.4 23.8 28.2 32.7 37.2 41.6 46.1 50.5
400 13.6 15.4 25.3 29.7 34.2 38.6 43.1 47.6 52.0
450 13.6 15.4 26.8 31.2 35.7 40.1 44.6 49.0 53.5
500 13.6 15.4 26.8 32.7 37.2 41.6 46.1 50.5 55.0
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X X 17.3 25.5 30.9 36.4 41.9 47.3 52.8
150 X 11.6 18.9 27.3 32.8 38.2 43.7 49.1 54.6
200 11.8 12.9 20.5 29.1 34.6 40.0 45.5 51.0 56.4
250 13.0 14.2 22.1 30.9 36.4 41.9 47.3 52.8 58.2
5/8 (3-1/8) 79 59.8 119.6 300 300 13.6 15.4 23.6 32.8 38.2 43.7 49.1 54.6 60.1 2.0 x Ncbgr
350 13.6 15.4 25.2 34.6 40.0 45.5 51.0 56.4 61.9
400 13.6 15.4 26.8 36.4 41.9 47.3 52.8 58.2 63.7
450 13.6 15.4 28.4 38.2 43.7 49.1 54.6 60.1 65.5
500 13.6 15.4 28.4 40.0 45.5 51.0 56.4 61.9 67.3
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X X 17.3 25.5 34.6 42.0 48.3 54.6 61.0
150 X 11.6 18.9 27.3 36.6 44.1 50.4 56.7 63.1
200 11.8 12.9 20.5 29.1 38.7 46.2 52.5 58.9 65.2
250 13.0 14.2 22.1 30.9 40.7 48.3 54.6 61.0 67.3
5/8 (3-1/8) 79 59.8 119.6 400 300 13.6 15.4 23.6 32.8 42.7 50.4 56.7 63.1 69.4 2.0 x Ncbgr
350 13.6 15.4 25.2 34.6 44.8 52.5 58.9 65.2 71.5
400 13.6 15.4 26.8 36.4 46.8 54.6 61.0 67.3 73.6
450 13.6 15.4 28.4 38.2 48.8 56.7 63.1 69.4 75.7
500 13.6 15.4 28.4 40.0 50.9 58.9 65.2 71.5 77.8
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X X 17.3 25.5 34.6 44.6 54.0 61.1 68.1
150 X 11.6 18.9 27.3 36.6 46.8 56.4 63.4 70.5
200 11.8 12.9 20.5 29.1 38.7 49.0 58.7 65.8 72.8
250 13.0 14.2 22.1 30.9 40.7 51.3 61.1 68.1 75.2
5/8 (3-1/8) 79 59.8 119.6 500 300 13.6 15.4 23.6 32.8 42.7 53.5 63.4 70.5 77.5 2.0 x Ncbgr
350 13.6 15.4 25.2 34.6 44.8 55.7 65.8 72.8 79.9
400 13.6 15.4 26.8 36.4 46.8 58.0 68.1 75.2 82.2
450 13.6 15.4 28.4 38.2 48.8 60.2 70.5 77.5 84.6
500 13.6 15.4 28.4 40.0 50.9 62.4 72.8 79.9 86.9
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X X 17.3 25.5 34.6 44.6 55.4 66.9 74.7
150 X 11.6 18.9 27.3 36.6 46.8 57.8 69.5 77.2
200 11.8 12.9 20.5 29.1 38.7 49.0 60.2 72.1 79.8
250 13.0 14.2 22.1 30.9 40.7 51.3 62.6 74.7 82.4
5/8 (3-1/8) 79 59.8 119.6 600 300 13.6 15.4 23.6 32.8 42.7 53.5 65.0 77.2 84.9 2.0 x Ncbgr
350 13.6 15.4 25.2 34.6 44.8 55.7 67.4 79.8 87.5
400 13.6 15.4 26.8 36.4 46.8 58.0 69.8 82.4 90.1
450 13.6 15.4 28.4 38.2 48.8 60.2 72.2 84.9 92.7
500 13.6 15.4 28.4 40.0 50.9 62.4 74.6 87.5 95.2

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 73
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 9 - Factored resistance for 2 or 4 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X X 17.3 25.5 34.6 44.6 55.4 66.9 79.2
150 X 11.6 18.9 27.3 36.6 46.8 57.8 69.5 81.9
200 11.8 12.9 20.5 29.1 38.7 49.0 60.2 72.1 84.6
250 13.0 14.2 22.1 30.9 40.7 51.3 62.6 74.7 87.4
5/8 (3-1/8) 79 59.8 119.6 675 300 13.6 15.4 23.6 32.8 42.7 53.5 65.0 77.2 90.1 2.0 x Ncbgr
350 13.6 15.4 25.2 34.6 44.8 55.7 67.4 79.8 92.8
400 13.6 15.4 26.8 36.4 46.8 58.0 69.8 82.4 95.6
450 13.6 15.4 28.4 38.2 48.8 60.2 72.2 84.9 98.3
500 13.6 15.4 28.4 40.0 50.9 62.4 74.6 87.5 101.0

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

74 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 10 - Factored resistance for 2 or 4 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 10.3 16.5 21.0 25.5 29.9 34.4 38.9 43.4
150 9.4 11.6 18.0 22.5 27.0 31.4 35.9 40.4 44.9
200 10.5 12.9 19.5 24.0 28.4 32.9 37.4 41.9 46.4
250 11.7 14.2 21.0 25.5 29.9 34.4 38.9 43.4 47.9
5/8 (4) 102 59.8 119.6 203 300 11.7 15.4 22.5 27.0 31.4 35.9 40.4 44.9 49.4 2.0 x Ncbgr
350 11.7 15.4 24.0 28.4 32.9 37.4 41.9 46.4 50.9
400 11.7 15.4 25.5 29.9 34.4 38.9 43.4 47.9 52.4
450 11.7 15.4 27.0 31.4 35.9 40.4 44.9 49.4 53.9
500 11.7 15.4 27.0 32.9 37.4 41.9 46.4 50.9 55.4
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 10.3 17.3 25.5 30.9 36.4 41.9 47.3 52.8
150 9.4 11.6 18.9 27.3 32.8 38.2 43.7 49.1 54.6
200 10.5 12.9 20.5 29.1 34.6 40.0 45.5 51.0 56.4
250 11.7 14.2 22.1 30.9 36.4 41.9 47.3 52.8 58.2
5/8 (4) 102 59.8 119.6 300 300 11.7 15.4 23.6 32.8 38.2 43.7 49.1 54.6 60.1 2.0 x Ncbgr
350 11.7 15.4 25.2 34.6 40.0 45.5 51.0 56.4 61.9
400 11.7 15.4 26.8 36.4 41.9 47.3 52.8 58.2 63.7
450 11.7 15.4 28.4 38.2 43.7 49.1 54.6 60.1 65.5
500 11.7 15.4 28.4 40.0 45.5 51.0 56.4 61.9 67.3
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 10.3 17.3 25.5 34.6 42.0 48.3 54.6 61.0
150 9.4 11.6 18.9 27.3 36.6 44.1 50.4 56.7 63.1
200 10.5 12.9 20.5 29.1 38.7 46.2 52.5 58.9 65.2
250 11.7 14.2 22.1 30.9 40.7 48.3 54.6 61.0 67.3
5/8 (4) 102 59.8 119.6 400 300 11.7 15.4 23.6 32.8 42.7 50.4 56.7 63.1 69.4 2.0 x Ncbgr
350 11.7 15.4 25.2 34.6 44.8 52.5 58.9 65.2 71.5
400 11.7 15.4 26.8 36.4 46.8 54.6 61.0 67.3 73.6
450 11.7 15.4 28.4 38.2 48.8 56.7 63.1 69.4 75.7
500 11.7 15.4 28.4 40.0 50.9 58.9 65.2 71.5 77.8
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 10.3 17.3 25.5 34.6 44.6 54.0 61.1 68.1
150 9.4 11.6 18.9 27.3 36.6 46.8 56.4 63.4 70.5
200 10.5 12.9 20.5 29.1 38.7 49.0 58.7 65.8 72.8
250 11.7 14.2 22.1 30.9 40.7 51.3 61.1 68.1 75.2
5/8 (4) 102 59.8 119.6 500 300 11.7 15.4 23.6 32.8 42.7 53.5 63.4 70.5 77.5 2.0 x Ncbgr
350 11.7 15.4 25.2 34.6 44.8 55.7 65.8 72.8 79.9
400 11.7 15.4 26.8 36.4 46.8 58.0 68.1 75.2 82.2
450 11.7 15.4 28.4 38.2 48.8 60.2 70.5 77.5 84.6
500 11.7 15.4 28.4 40.0 50.9 62.4 72.8 79.9 86.9
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 10.3 17.3 25.5 34.6 44.6 55.4 66.9 74.7
150 9.4 11.6 18.9 27.3 36.6 46.8 57.8 69.5 77.2
200 10.5 12.9 20.5 29.1 38.7 49.0 60.2 72.1 79.8
250 11.7 14.2 22.1 30.9 40.7 51.3 62.6 74.7 82.4
5/8 (4) 102 59.8 119.6 600 300 11.7 15.4 23.6 32.8 42.7 53.5 65.0 77.2 84.9 2.0 x Ncbgr
350 11.7 15.4 25.2 34.6 44.8 55.7 67.4 79.8 87.5
400 11.7 15.4 26.8 36.4 46.8 58.0 69.8 82.4 90.1
450 11.7 15.4 28.4 38.2 48.8 60.2 72.2 84.9 92.7
500 11.7 15.4 28.4 40.0 50.9 62.4 74.6 87.5 95.2
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 10.3 17.3 25.5 34.6 44.6 55.4 66.9 79.2
150 9.4 11.6 18.9 27.3 36.6 46.8 57.8 69.5 81.9
200 10.5 12.9 20.5 29.1 38.7 49.0 60.2 72.1 84.6
250 11.7 14.2 22.1 30.9 40.7 51.3 62.6 74.7 87.4
5/8 (4) 102 59.8 119.6 675 300 11.7 15.4 23.6 32.8 42.7 53.5 65.0 77.2 90.1 2.0 x Ncbgr
350 11.7 15.4 25.2 34.6 44.8 55.7 67.4 79.8 92.8
400 11.7 15.4 26.8 36.4 46.8 58.0 69.8 82.4 95.6
450 11.7 15.4 28.4 38.2 48.8 60.2 72.2 84.9 98.3
500 11.7 15.4 28.4 40.0 50.9 62.4 74.6 87.5 101.0

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 75
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 11 - Factored resistance for 2 or 4 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
150 X X X X 29.5 34.5 39.4 44.3 49.2
200 X X X 26.3 31.2 36.1 41.0 46.0 50.9
250 X X 23.0 27.9 32.8 37.7 42.7 47.6 52.5
300 20.6 X 24.6 29.5 34.5 39.4 44.3 49.2 54.2
3/4 (3-3/4) 95 90.4 180.8 203 2.0 x Ncbgr
350 22.1 X 26.3 31.2 36.1 41.0 46.0 50.9 55.8
400 22.5 X 27.9 32.8 37.7 42.7 47.6 52.5 57.4
450 22.5 X 29.5 34.5 39.4 44.3 49.2 54.2 59.1
500 22.5 X 29.5 36.1 41.0 46.0 50.9 55.8 60.7
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X X 35.9 41.9 47.9 53.9 59.8
200 X X X 31.9 37.9 43.9 49.9 55.9 61.8
250 X X 24.2 33.9 39.9 45.9 51.9 57.9 63.8
300 20.6 X 25.9 35.9 41.9 47.9 53.9 59.8 65.8
3/4 (3-3/4) 95 90.4 180.8 300 2.0 x Ncbgr
350 22.1 X 27.6 37.9 43.9 49.9 55.9 61.8 67.8
400 22.5 X 29.4 39.9 45.9 51.9 57.9 63.8 69.8
450 22.5 X 31.1 41.9 47.9 53.9 59.8 65.8 71.8
500 22.5 X 31.1 43.9 49.9 55.9 61.8 67.8 73.8
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X X 40.1 48.4 55.3 62.2 69.1
200 X X X 31.9 42.4 50.7 57.6 64.5 71.4
250 X X 24.2 33.9 44.6 53.0 59.9 66.8 73.7
300 20.6 X 25.9 35.9 46.8 55.3 62.2 69.1 76.0
3/4 (3-3/4) 95 90.4 180.8 400 2.0 x Ncbgr
350 22.1 X 27.6 37.9 49.1 57.6 64.5 71.4 78.3
400 22.5 X 29.4 39.9 51.3 59.9 66.8 73.7 80.6
450 22.5 X 31.1 41.9 53.5 62.2 69.1 76.0 82.9
500 22.5 X 31.1 43.9 55.8 64.5 71.4 78.3 85.2
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X X 40.1 51.3 61.8 69.5 77.3
200 X X X 31.9 42.4 53.8 64.4 72.1 79.8
250 X X 24.2 33.9 44.6 56.2 67.0 74.7 82.4
300 20.6 X 25.9 35.9 46.8 58.6 69.5 77.3 85.0
3/4 (3-3/4) 95 90.4 180.8 500 2.0 x Ncbgr
350 22.1 X 27.6 37.9 49.1 61.1 72.1 79.8 87.6
400 22.5 X 29.4 39.9 51.3 63.5 74.7 82.4 90.1
450 22.5 X 31.1 41.9 53.5 66.0 77.3 85.0 92.7
500 22.5 X 31.1 43.9 55.8 68.4 79.8 87.6 95.3
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X X 40.1 51.3 63.3 76.2 84.6
200 X X X 31.9 42.4 53.8 66.0 79.0 87.5
250 X X 24.2 33.9 44.6 56.2 68.6 81.8 90.3
300 20.6 X 25.9 35.9 46.8 58.6 71.3 84.6 93.1
3/4 (3-3/4) 95 90.4 180.8 600 2.0 x Ncbgr
350 22.1 X 27.6 37.9 49.1 61.1 73.9 87.5 95.9
400 22.5 X 29.4 39.9 51.3 63.5 76.5 90.3 98.7
450 22.5 X 31.1 41.9 53.5 66.0 79.2 93.1 101.6
500 22.5 X 31.1 43.9 55.8 68.4 81.8 95.9 104.4
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X X 40.1 51.3 63.3 76.2 89.8
200 X X X 31.9 42.4 53.8 66.0 79.0 92.8
250 X X 24.2 33.9 44.6 56.2 68.6 81.8 95.8
300 20.6 X 25.9 35.9 46.8 58.6 71.3 84.6 98.8
3/4 (3-3/4) 95 90.4 180.8 675 2.0 x Ncbgr
350 22.1 X 27.6 37.9 49.1 61.1 73.9 87.5 101.7
400 22.5 X 29.4 39.9 51.3 63.5 76.5 90.3 104.7
450 22.5 X 31.1 41.9 53.5 66.0 79.2 93.1 107.7
500 22.5 X 31.1 43.9 55.8 68.4 81.8 95.9 110.7

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

76 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 12 - Factored resistance for 2 or 4 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
150 X X X 24.6 29.5 34.5 39.4 44.3 49.2
200 X X 21.3 26.3 31.2 36.1 41.0 46.0 50.9
250 16.3 X 23.0 27.9 32.8 37.7 42.7 47.6 52.5
300 17.8 X 24.6 29.5 34.5 39.4 44.3 49.2 54.2
3/4 (4-3/4) 121 90.4 180.8 203 2.0 x Ncbgr
350 18.2 X 26.3 31.2 36.1 41.0 46.0 50.9 55.8
400 18.2 X 27.9 32.8 37.7 42.7 47.6 52.5 57.4
450 18.2 X 29.5 34.5 39.4 44.3 49.2 54.2 59.1
500 18.2 X 29.5 36.1 41.0 46.0 50.9 55.8 60.7
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X 29.9 35.9 41.9 47.9 53.9 59.8
200 X X 22.5 31.9 37.9 43.9 49.9 55.9 61.8
250 16.3 X 24.2 33.9 39.9 45.9 51.9 57.9 63.8
300 17.8 X 25.9 35.9 41.9 47.9 53.9 59.8 65.8
3/4 (4-3/4) 121 90.4 180.8 300 2.0 x Ncbgr
350 18.2 X 27.6 37.9 43.9 49.9 55.9 61.8 67.8
400 18.2 X 29.4 39.9 45.9 51.9 57.9 63.8 69.8
450 18.2 X 31.1 41.9 47.9 53.9 59.8 65.8 71.8
500 18.2 X 31.1 43.9 49.9 55.9 61.8 67.8 73.8
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X 29.9 40.1 48.4 55.3 62.2 69.1
200 X X 22.5 31.9 42.4 50.7 57.6 64.5 71.4
250 16.3 X 24.2 33.9 44.6 53.0 59.9 66.8 73.7
300 17.8 X 25.9 35.9 46.8 55.3 62.2 69.1 76.0 2.0 x Ncbgr
3/4 (4-3/4) 121 90.4 180.8 400
350 18.2 X 27.6 37.9 49.1 57.6 64.5 71.4 78.3
400 18.2 X 29.4 39.9 51.3 59.9 66.8 73.7 80.6
450 18.2 X 31.1 41.9 53.5 62.2 69.1 76.0 82.9
500 18.2 X 31.1 43.9 55.8 64.5 71.4 78.3 85.2
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X 29.9 40.1 51.3 61.8 69.5 77.3
200 X X 22.5 31.9 42.4 53.8 64.4 72.1 79.8
250 16.3 X 24.2 33.9 44.6 56.2 67.0 74.7 82.4
300 17.8 X 25.9 35.9 46.8 58.6 69.5 77.3 85.0
3/4 (4-3/4) 121 90.4 180.8 500 2.0 x Ncbgr
350 18.2 X 27.6 37.9 49.1 61.1 72.1 79.8 87.6
400 18.2 X 29.4 39.9 51.3 63.5 74.7 82.4 90.1
450 18.2 X 31.1 41.9 53.5 66.0 77.3 85.0 92.7
500 18.2 X 31.1 43.9 55.8 68.4 79.8 87.6 95.3
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X 29.9 40.1 51.3 63.3 76.2 84.6
200 X X 22.5 31.9 42.4 53.8 66.0 79.0 87.5
250 16.3 X 24.2 33.9 44.6 56.2 68.6 81.8 90.3
300 17.8 X 25.9 35.9 46.8 58.6 71.3 84.6 93.1
3/4 (4-3/4) 121 90.4 180.8 600 2.0 x Ncbgr
350 18.2 X 27.6 37.9 49.1 61.1 73.9 87.5 95.9
400 18.2 X 29.4 39.9 51.3 63.5 76.5 90.3 98.7
450 18.2 X 31.1 41.9 53.5 66.0 79.2 93.1 101.6
500 18.2 X 31.1 43.9 55.8 68.4 81.8 95.9 104.4
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X 29.9 40.1 51.3 63.3 76.2 89.8
200 X X 22.5 31.9 42.4 53.8 66.0 79.0 92.8
250 16.3 X 24.2 33.9 44.6 56.2 68.6 81.8 95.8
300 17.8 X 25.9 35.9 46.8 58.6 71.3 84.6 98.8
3/4 (4-3/4) 121 90.4 180.8 675 2.0 x Ncbgr
350 18.2 X 27.6 37.9 49.1 61.1 73.9 87.5 101.7
400 18.2 X 29.4 39.9 51.3 63.5 76.5 90.3 104.7
450 18.2 X 31.1 41.9 53.5 66.0 79.2 93.1 107.7
500 18.2 X 31.1 43.9 55.8 68.4 81.8 95.9 110.7

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 77
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 13 - Factored resistance for 3 or 6 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 9.2 11.9 14.6 17.4 20.1 22.9 25.6 28.4
150 7.8 11.0 13.7 16.5 19.2 22.0 24.7 27.5 30.2
200 9.2 12.8 15.6 18.3 21.1 23.8 26.5 29.3 32.0
250 9.2 14.6 17.4 20.1 22.9 25.6 28.4 31.1 33.9
3/8 (2) 51 30.6 61.2 127 300 9.2 16.5 19.2 22.0 24.7 27.5 30.2 33.0 35.7 1.0 x Ncbgr
350 9.2 16.5 21.1 23.8 26.5 29.3 32.0 34.8 37.5
400 9.2 16.5 22.9 25.6 28.4 31.1 33.9 36.6 39.4
450 9.2 16.5 24.7 27.5 30.2 33.0 35.7 38.4 41.2
500 9.2 16.5 24.7 29.3 32.0 34.8 37.5 40.3 43.0
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.9 14.9 18.4 21.8 25.3 28.7 32.2 35.6
150 7.8 11.9 17.2 20.7 24.1 27.6 31.0 34.5 37.9
200 9.2 13.9 19.5 23.0 26.4 29.9 33.3 36.8 40.2
250 9.2 15.9 21.8 25.3 28.7 32.2 35.6 39.1 42.5
3/8 (2) 51 30.6 61.2 200 300 9.2 17.9 24.1 27.6 31.0 34.5 37.9 41.4 44.8 1.0 x Ncbgr
350 9.2 17.9 26.4 29.9 33.3 36.8 40.2 43.7 47.1
400 9.2 17.9 28.7 32.2 35.6 39.1 42.5 46.0 49.4
450 9.2 17.9 31.0 34.5 37.9 41.4 44.8 48.2 51.7
500 9.2 17.9 31.0 36.8 40.2 43.7 47.1 50.5 54.0
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.9 15.8 22.5 26.7 31.0 35.2 39.4 43.6
150 7.8 11.9 18.3 25.3 29.5 33.8 38.0 42.2 46.4
200 9.2 13.9 20.7 28.1 32.4 36.6 40.8 45.0 49.2
250 9.2 15.9 23.2 31.0 35.2 39.4 43.6 47.8 52.1
3/8 (2) 51 30.6 61.2 300 300 9.2 17.9 25.6 33.8 38.0 42.2 46.4 50.7 54.9 1.0 x Ncbgr
350 9.2 17.9 28.0 36.6 40.8 45.0 49.2 53.5 57.7
400 9.2 17.9 30.5 39.4 43.6 47.8 52.1 56.3 60.5
450 9.2 17.9 32.9 42.2 46.4 50.7 54.9 59.1 63.3
500 9.2 17.9 32.9 45.0 49.2 53.5 57.7 61.9 66.1
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.9 15.8 22.5 29.9 35.7 40.6 45.5 50.4
150 7.8 11.9 18.3 25.3 33.0 39.0 43.9 48.7 53.6
200 9.2 13.9 20.7 28.1 36.2 42.2 47.1 52.0 56.9
250 9.2 15.9 23.2 31.0 39.3 45.5 50.4 55.2 60.1
3/8 (2) 51 30.6 61.2 400 300 9.2 17.9 25.6 33.8 42.5 48.7 53.6 58.5 63.4 1.0 x Ncbgr
350 9.2 17.9 28.0 36.6 45.6 52.0 56.9 61.7 66.6
400 9.2 17.9 30.5 39.4 48.8 55.2 60.1 65.0 69.9
450 9.2 17.9 32.9 42.2 51.9 58.5 63.4 68.2 73.1
500 9.2 17.9 32.9 45.0 55.1 61.7 66.6 71.5 76.4
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.9 15.8 22.5 29.9 37.9 45.4 50.9 56.3
150 7.8 11.9 18.3 25.3 33.0 41.4 49.0 54.5 59.9
200 9.2 13.9 20.7 28.1 36.2 44.8 52.7 58.1 63.6
250 9.2 15.9 23.2 31.0 39.3 48.2 56.3 61.8 67.2
3/8 (2) 51 30.6 61.2 500 300 9.2 17.9 25.6 33.8 42.5 51.7 59.9 65.4 70.8 1.0 x Ncbgr
350 9.2 17.9 28.0 36.6 45.6 55.1 63.6 69.0 74.5
400 9.2 17.9 30.5 39.4 48.8 58.6 67.2 72.7 78.1
450 9.2 17.9 32.9 42.2 51.9 62.0 70.8 76.3 81.7
500 9.2 17.9 32.9 45.0 55.1 65.5 74.5 79.9 85.4
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 9.9 15.8 22.5 29.9 37.9 46.5 55.7 61.7
150 7.8 11.9 18.3 25.3 33.0 41.4 50.3 59.7 65.7
200 9.2 13.9 20.7 28.1 36.2 44.8 54.0 63.7 69.6
250 9.2 15.9 23.2 31.0 39.3 48.2 57.7 67.7 73.6
3/8 (2) 51 30.6 61.2 600 300 9.2 17.9 25.6 33.8 42.5 51.7 61.4 71.6 77.6 1.0 x Ncbgr
350 9.2 17.9 28.0 36.6 45.6 55.1 65.1 75.6 81.6
400 9.2 17.9 30.5 39.4 48.8 58.6 68.9 79.6 85.6
450 9.2 17.9 32.9 42.2 51.9 62.0 72.6 83.6 89.5
500 9.2 17.9 32.9 45.0 55.1 65.5 76.3 87.5 93.5

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

78 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 13 - Factored resistance for 3 or 6 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 9.9 15.8 22.5 29.9 37.9 46.5 55.7 65.4
150 7.8 11.9 18.3 25.3 33.0 41.4 50.3 59.7 69.6
200 9.2 13.9 20.7 28.1 36.2 44.8 54.0 63.7 73.9
250 9.2 15.9 23.2 31.0 39.3 48.2 57.7 67.7 78.1
3/8 (2) 51 30.6 61.2 675 300 9.2 17.9 25.6 33.8 42.5 51.7 61.4 71.6 82.3 1.0 x Ncbgr
350 9.2 17.9 28.0 36.6 45.6 55.1 65.1 75.6 86.5
400 9.2 17.9 30.5 39.4 48.8 58.6 68.9 79.6 90.8
450 9.2 17.9 32.9 42.2 51.9 62.0 72.6 83.6 95.0
500 9.2 17.9 32.9 45.0 55.1 65.5 76.3 87.5 99.2

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00 s s
25 1.12
30 1.22 V V
35 1.32 s s
40 1.41
45 1.50
50 1.58
c1 c1 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 79
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 14 - Factored resistance for 3 or 6 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 11.5 15.1 18.5 22.0 25.5 28.9 32.4 35.9
150 9.8 13.8 17.4 20.8 24.3 27.8 31.3 34.7 38.2
200 11.7 16.1 19.7 23.2 26.6 30.1 33.6 37.1 40.5
250 12.1 18.4 22.0 25.5 28.9 32.4 35.9 39.4 42.8
1/2 (2) 51 54.6 109.2 152 300 12.1 20.7 24.3 27.8 31.3 34.7 38.2 41.7 45.2 1.0 x Ncbgr
350 12.1 20.7 26.6 30.1 33.6 37.1 40.5 44.0 47.5
400 12.1 20.7 28.9 32.4 35.9 39.4 42.8 46.3 49.8
450 12.1 20.7 31.3 34.7 38.2 41.7 45.2 48.6 52.1
500 12.1 20.7 31.3 37.1 40.5 44.0 47.5 50.9 54.4
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 11.5 17.3 21.3 25.2 29.2 33.2 37.2 41.2
150 9.8 13.8 19.9 23.9 27.9 31.9 35.9 39.8 43.8
200 11.7 16.1 22.6 26.6 30.5 34.5 38.5 42.5 46.5
250 12.1 18.4 25.2 29.2 33.2 37.2 41.2 45.2 49.1
1/2 (2) 51 54.6 109.2 200 300 12.1 20.7 27.9 31.9 35.9 39.8 43.8 47.8 51.8 1.0 x Ncbgr
350 12.1 20.7 30.5 34.5 38.5 42.5 46.5 50.5 54.5
400 12.1 20.7 33.2 37.2 41.2 45.2 49.1 53.1 57.1
450 12.1 20.7 35.9 39.8 43.8 47.8 51.8 55.8 59.8
500 12.1 20.7 35.9 42.5 46.5 50.5 54.5 58.4 62.4
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 30.9 35.8 40.7 45.5 50.4
150 9.8 13.8 21.1 29.3 34.2 39.0 43.9 48.8 53.7
200 11.7 16.1 24.0 32.5 37.4 42.3 47.2 52.1 56.9
250 12.1 18.4 26.8 35.8 40.7 45.5 50.4 55.3 60.2
1/2 (2) 51 54.6 109.2 300 300 12.1 20.7 29.6 39.0 43.9 48.8 53.7 58.6 63.4 1.0 x Ncbgr
350 12.1 20.7 32.4 42.3 47.2 52.1 56.9 61.8 66.7
400 12.1 20.7 35.2 45.5 50.4 55.3 60.2 65.1 70.0
450 12.1 20.7 38.0 48.8 53.7 58.6 63.4 68.3 73.2
500 12.1 20.7 38.0 52.1 56.9 61.8 66.7 71.6 76.5
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 34.6 41.3 47.0 52.6 58.2
150 9.8 13.8 21.1 29.3 38.2 45.1 50.7 56.4 62.0
200 11.7 16.1 24.0 32.5 41.8 48.8 54.5 60.1 65.7
250 12.1 18.4 26.8 35.8 45.5 52.6 58.2 63.9 69.5
1/2 (2) 51 54.6 109.2 400 300 12.1 20.7 29.6 39.0 49.1 56.4 62.0 67.6 73.3 1.0 x Ncbgr
350 12.1 20.7 32.4 42.3 52.7 60.1 65.7 71.4 77.0
400 12.1 20.7 35.2 45.5 56.4 63.9 69.5 75.1 80.8
450 12.1 20.7 38.0 48.8 60.0 67.6 73.3 78.9 84.5
500 12.1 20.7 38.0 52.1 63.7 71.4 77.0 82.7 88.3
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 34.6 43.8 52.5 58.8 65.1
150 9.8 13.8 21.1 29.3 38.2 47.8 56.7 63.0 69.3
200 11.7 16.1 24.0 32.5 41.8 51.8 60.9 67.2 73.5
250 12.1 18.4 26.8 35.8 45.5 55.8 65.1 71.4 77.7
1/2 (2) 51 54.6 109.2 500 300 12.1 20.7 29.6 39.0 49.1 59.8 69.3 75.6 81.9 1.0 x Ncbgr
350 12.1 20.7 32.4 42.3 52.7 63.8 73.5 79.8 86.1
400 12.1 20.7 35.2 45.5 56.4 67.7 77.7 84.0 90.3
450 12.1 20.7 38.0 48.8 60.0 71.7 81.9 88.2 94.5
500 12.1 20.7 38.0 52.1 63.7 75.7 86.1 92.4 98.7
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 34.6 43.8 53.8 64.4 71.3
150 9.8 13.8 21.1 29.3 38.2 47.8 58.1 69.0 75.9
200 11.7 16.1 24.0 32.5 41.8 51.8 62.4 73.6 80.5
250 12.1 18.4 26.8 35.8 45.5 55.8 66.7 78.2 85.1
1/2 (2) 51 54.6 109.2 600 300 12.1 20.7 29.6 39.0 49.1 59.8 71.0 82.8 89.7 1.0 x Ncbgr
350 12.1 20.7 32.4 42.3 52.7 63.8 75.3 87.4 94.3
400 12.1 20.7 35.2 45.5 56.4 67.7 79.6 92.0 98.9
450 12.1 20.7 38.0 48.8 60.0 71.7 83.9 96.6 103.5
500 12.1 20.7 38.0 52.1 63.7 75.7 88.2 101.2 108.1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

80 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 14 - Factored resistance for 3 or 6 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 11.5 18.3 26.0 34.6 43.8 53.8 64.4 75.6
150 9.8 13.8 21.1 29.3 38.2 47.8 58.1 69.0 80.5
200 11.7 16.1 24.0 32.5 41.8 51.8 62.4 73.6 85.4
250 12.1 18.4 26.8 35.8 45.5 55.8 66.7 78.2 90.3
1/2 (2) 51 54.6 109.2 675 300 12.1 20.7 29.6 39.0 49.1 59.8 71.0 82.8 95.2 1.0 x Ncbgr
350 12.1 20.7 32.4 42.3 52.7 63.8 75.3 87.4 100.0
400 12.1 20.7 35.2 45.5 56.4 67.7 79.6 92.0 104.9
450 12.1 20.7 38.0 48.8 60.0 71.7 83.9 96.6 109.8
500 12.1 20.7 38.0 52.1 63.7 75.7 88.2 101.2 114.7

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12 s s
30 1.22
35 1.32 V V
40 1.41 s s
45 1.50
50 1.58
55 1.66
c1 c1 s

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 81
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 15 - Factored resistance for 3 or 6 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 11.5 17.4 21.4 25.4 29.4 33.5 37.5 41.5
150 8.6 13.8 20.1 24.1 28.1 32.1 36.1 40.1 44.2
200 9.6 16.1 22.7 26.8 30.8 34.8 38.8 42.8 46.8
250 9.6 18.4 25.4 29.4 33.5 37.5 41.5 45.5 49.5
1/2 (3-1/4) 83 54.6 109.2 203 300 9.6 20.7 28.1 32.1 36.1 40.1 44.2 48.2 52.2 2.0 x Ncbgr
350 9.6 20.7 30.8 34.8 38.8 42.8 46.8 50.9 54.9
400 9.6 20.7 33.5 37.5 41.5 45.5 49.5 53.5 57.5
450 9.6 20.7 36.1 40.1 44.2 48.2 52.2 56.2 60.2
500 9.6 20.7 36.1 42.8 46.8 50.9 54.9 58.9 62.9
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 30.9 35.8 40.7 45.5 50.4
150 8.6 13.8 21.1 29.3 34.2 39.0 43.9 48.8 53.7
200 9.6 16.1 24.0 32.5 37.4 42.3 47.2 52.1 56.9
250 9.6 18.4 26.8 35.8 40.7 45.5 50.4 55.3 60.2
1/2 (3-1/4) 83 54.6 109.2 300 300 9.6 20.7 29.6 39.0 43.9 48.8 53.7 58.6 63.4 2.0 x Ncbgr
350 9.6 20.7 32.4 42.3 47.2 52.1 56.9 61.8 66.7
400 9.6 20.7 35.2 45.5 50.4 55.3 60.2 65.1 70.0
450 9.6 20.7 38.0 48.8 53.7 58.6 63.4 68.3 73.2
500 9.6 20.7 38.0 52.1 56.9 61.8 66.7 71.6 76.5
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 34.6 41.3 47.0 52.6 58.2
150 8.6 13.8 21.1 29.3 38.2 45.1 50.7 56.4 62.0
200 9.6 16.1 24.0 32.5 41.8 48.8 54.5 60.1 65.7
250 9.6 18.4 26.8 35.8 45.5 52.6 58.2 63.9 69.5
1/2 (3-1/4) 83 54.6 109.2 400 300 9.6 20.7 29.6 39.0 49.1 56.4 62.0 67.6 73.3 2.0 x Ncbgr
350 9.6 20.7 32.4 42.3 52.7 60.1 65.7 71.4 77.0
400 9.6 20.7 35.2 45.5 56.4 63.9 69.5 75.1 80.8
450 9.6 20.7 38.0 48.8 60.0 67.6 73.3 78.9 84.5
500 9.6 20.7 38.0 52.1 63.7 71.4 77.0 82.7 88.3
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 34.6 43.8 52.5 58.8 65.1
150 8.6 13.8 21.1 29.3 38.2 47.8 56.7 63.0 69.3
200 9.6 16.1 24.0 32.5 41.8 51.8 60.9 67.2 73.5
250 9.6 18.4 26.8 35.8 45.5 55.8 65.1 71.4 77.7
1/2 (3-1/4) 83 54.6 109.2 500 300 9.6 20.7 29.6 39.0 49.1 59.8 69.3 75.6 81.9 2.0 x Ncbgr
350 9.6 20.7 32.4 42.3 52.7 63.8 73.5 79.8 86.1
400 9.6 20.7 35.2 45.5 56.4 67.7 77.7 84.0 90.3
450 9.6 20.7 38.0 48.8 60.0 71.7 81.9 88.2 94.5
500 9.6 20.7 38.0 52.1 63.7 75.7 86.1 92.4 98.7
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 34.6 43.8 53.8 64.4 71.3
150 8.6 13.8 21.1 29.3 38.2 47.8 58.1 69.0 75.9
200 9.6 16.1 24.0 32.5 41.8 51.8 62.4 73.6 80.5
250 9.6 18.4 26.8 35.8 45.5 55.8 66.7 78.2 85.1
1/2 (3-1/4) 83 54.6 109.2 600 300 9.6 20.7 29.6 39.0 49.1 59.8 71.0 82.8 89.7 2.0 x Ncbgr
350 9.6 20.7 32.4 42.3 52.7 63.8 75.3 87.4 94.3
400 9.6 20.7 35.2 45.5 56.4 67.7 79.6 92.0 98.9
450 9.6 20.7 38.0 48.8 60.0 71.7 83.9 96.6 103.5
500 9.6 20.7 38.0 52.1 63.7 75.7 88.2 101.2 108.1
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 34.6 43.8 53.8 64.4 75.6
150 8.6 13.8 21.1 29.3 38.2 47.8 58.1 69.0 80.5
200 9.6 16.1 24.0 32.5 41.8 51.8 62.4 73.6 85.4
250 9.6 18.4 26.8 35.8 45.5 55.8 66.7 78.2 90.3
1/2 (3-1/4) 83 54.6 109.2 675 300 9.6 20.7 29.6 39.0 49.1 59.8 71.0 82.8 95.2 2.0 x Ncbgr
350 9.6 20.7 32.4 42.3 52.7 63.8 75.3 87.4 100.0
400 9.6 20.7 35.2 45.5 56.4 67.7 79.6 92.0 104.9
450 9.6 20.7 38.0 48.8 60.0 71.7 83.9 96.6 109.8
500 9.6 20.7 38.0 52.1 63.7 75.7 88.2 101.2 114.7

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00 s
25 1.12
30 1.22 V V
35 1.32 s s
40 1.41
45 1.50
50 1.58
c1 c1 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

82 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 16 - Factored resistance for 3 or 6 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X X 15.4 18.9 22.5 26.1 29.6 33.2 36.7
150 X 14.2 17.8 21.3 24.9 28.4 32.0 35.5 39.1
200 16.0 16.6 20.1 23.7 27.2 30.8 34.3 37.9 41.5
250 18.4 18.9 22.5 26.1 29.6 33.2 36.7 40.3 43.8
5/8 (3-1/8) 79 89.7 179.4 127 300 19.6 21.3 24.9 28.4 32.0 35.5 39.1 42.6 46.2 2.0 x Ncbgr
350 19.6 21.3 27.2 30.8 34.3 37.9 41.5 45.0 48.6
400 19.6 21.3 29.6 33.2 36.7 40.3 43.8 47.4 50.9
450 19.6 21.3 32.0 35.5 39.1 42.6 46.2 49.7 53.3
500 19.6 21.3 32.0 37.9 41.5 45.0 48.6 52.1 55.7
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X X 19.3 23.8 28.2 32.7 37.2 41.6 46.1
150 X 15.4 22.3 26.8 31.2 35.7 40.1 44.6 49.0
200 16.7 18.0 25.3 29.7 34.2 38.6 43.1 47.6 52.0
250 19.2 20.6 28.2 32.7 37.2 41.6 46.1 50.5 55.0
5/8 (3-1/8) 79 89.7 179.4 200 300 20.4 23.2 31.2 35.7 40.1 44.6 49.0 53.5 58.0 2.0 x Ncbgr
350 20.4 23.2 34.2 38.6 43.1 47.6 52.0 56.5 60.9
400 20.4 23.2 37.2 41.6 46.1 50.5 55.0 59.4 63.9
450 20.4 23.2 40.1 44.6 49.0 53.5 58.0 62.4 66.9
500 20.4 23.2 40.1 47.6 52.0 56.5 60.9 65.4 69.9
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X X 20.5 29.1 34.6 40.0 45.5 51.0 56.4
150 X 15.4 23.6 32.8 38.2 43.7 49.1 54.6 60.1
200 16.7 18.0 26.8 36.4 41.9 47.3 52.8 58.2 63.7
250 19.2 20.6 30.0 40.0 45.5 51.0 56.4 61.9 67.3
5/8 (3-1/8) 79 89.7 179.4 300 300 20.4 23.2 33.1 43.7 49.1 54.6 60.1 65.5 71.0 2.0 x Ncbgr
350 20.4 23.2 36.3 47.3 52.8 58.2 63.7 69.2 74.6
400 20.4 23.2 39.4 51.0 56.4 61.9 67.3 72.8 78.3
450 20.4 23.2 42.6 54.6 60.1 65.5 71.0 76.4 81.9
500 20.4 23.2 42.6 58.2 63.7 69.2 74.6 80.1 85.6
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X X 20.5 29.1 38.7 46.2 52.5 58.9 65.2
150 X 15.4 23.6 32.8 42.7 50.4 56.7 63.1 69.4
200 16.7 18.0 26.8 36.4 46.8 54.6 61.0 67.3 73.6
250 19.2 20.6 30.0 40.0 50.9 58.9 65.2 71.5 77.8
5/8 (3-1/8) 79 89.7 179.4 400 300 20.4 23.2 33.1 43.7 54.9 63.1 69.4 75.7 82.0 2.0 x Ncbgr
350 20.4 23.2 36.3 47.3 59.0 67.3 73.6 79.9 86.2
400 20.4 23.2 39.4 51.0 63.1 71.5 77.8 84.1 90.4
450 20.4 23.2 42.6 54.6 67.2 75.7 82.0 88.3 94.6
500 20.4 23.2 42.6 58.2 71.2 79.9 86.2 92.5 98.8
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X X 20.5 29.1 38.7 49.0 58.7 65.8 72.8
150 X 15.4 23.6 32.8 42.7 53.5 63.4 70.5 77.5
200 16.7 18.0 26.8 36.4 46.8 58.0 68.1 75.2 82.2
250 19.2 20.6 30.0 40.0 50.9 62.4 72.8 79.9 86.9
5/8 (3-1/8) 79 89.7 179.4 500 300 20.4 23.2 33.1 43.7 54.9 66.9 77.5 84.6 91.6 2.0 x Ncbgr
350 20.4 23.2 36.3 47.3 59.0 71.3 82.2 89.3 96.3
400 20.4 23.2 39.4 51.0 63.1 75.8 86.9 94.0 101.0
450 20.4 23.2 42.6 54.6 67.2 80.3 91.6 98.7 105.7
500 20.4 23.2 42.6 58.2 71.2 84.7 96.3 103.4 110.4
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X X 20.5 29.1 38.7 49.0 60.2 72.1 79.8
150 X 15.4 23.6 32.8 42.7 53.5 65.0 77.2 84.9
200 16.7 18.0 26.8 36.4 46.8 58.0 69.8 82.4 90.1
250 19.2 20.6 30.0 40.0 50.9 62.4 74.6 87.5 95.2
5/8 (3-1/8) 79 89.7 179.4 600 300 20.4 23.2 33.1 43.7 54.9 66.9 79.5 92.7 100.4 2.0 x Ncbgr
350 20.4 23.2 36.3 47.3 59.0 71.3 84.3 97.8 105.5
400 20.4 23.2 39.4 51.0 63.1 75.8 89.1 103.0 110.7
450 20.4 23.2 42.6 54.6 67.2 80.3 93.9 108.1 115.8
500 20.4 23.2 42.6 58.2 71.2 84.7 98.7 113.3 121.0

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 83
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 16 - Factored resistance for 3 or 6 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X X 20.5 29.1 38.7 49.0 60.2 72.1 84.6
150 X 15.4 23.6 32.8 42.7 53.5 65.0 77.2 90.1
200 16.7 18.0 26.8 36.4 46.8 58.0 69.8 82.4 95.6
250 19.2 20.6 30.0 40.0 50.9 62.4 74.6 87.5 101.0
5/8 (3-1/8) 79 89.7 179.4 675 300 20.4 23.2 33.1 43.7 54.9 66.9 79.5 92.7 106.5 2.0 x Ncbgr
350 20.4 23.2 36.3 47.3 59.0 71.3 84.3 97.8 111.9
400 20.4 23.2 39.4 51.0 63.1 75.8 89.1 103.0 117.4
450 20.4 23.2 42.6 54.6 67.2 80.3 93.9 108.1 122.9
500 20.4 23.2 42.6 58.2 71.2 84.7 98.7 113.3 128.3

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00 s s
25 1.12
30 1.22 V V
35 1.32 s s
40 1.41
45 1.50
50 1.58
c1 c1 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

84 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 17 - Factored resistance for 3 or 6 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 12.9 19.5 24.0 28.4 32.9 37.4 41.9 46.4
150 12.9 15.4 22.5 27.0 31.4 35.9 40.4 44.9 49.4
200 15.2 18.0 25.5 29.9 34.4 38.9 43.4 47.9 52.4
250 17.5 20.6 28.4 32.9 37.4 41.9 46.4 50.9 55.4
5/8 (4) 102 89.7 179.4 203 300 17.5 23.2 31.4 35.9 40.4 44.9 49.4 53.9 58.4 2.0 x Ncbgr
350 17.5 23.2 34.4 38.9 43.4 47.9 52.4 56.9 61.4
400 17.5 23.2 37.4 41.9 46.4 50.9 55.4 59.9 64.4
450 17.5 23.2 40.4 44.9 49.4 53.9 58.4 62.9 67.4
500 17.5 23.2 40.4 47.9 52.4 56.9 61.4 65.9 70.4
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 34.6 40.0 45.5 51.0 56.4
150 12.9 15.4 23.6 32.8 38.2 43.7 49.1 54.6 60.1
200 15.2 18.0 26.8 36.4 41.9 47.3 52.8 58.2 63.7
250 17.5 20.6 30.0 40.0 45.5 51.0 56.4 61.9 67.3
5/8 (4) 102 89.7 179.4 300 300 17.5 23.2 33.1 43.7 49.1 54.6 60.1 65.5 71.0 2.0 x Ncbgr
350 17.5 23.2 36.3 47.3 52.8 58.2 63.7 69.2 74.6
400 17.5 23.2 39.4 51.0 56.4 61.9 67.3 72.8 78.3
450 17.5 23.2 42.6 54.6 60.1 65.5 71.0 76.4 81.9
500 17.5 23.2 42.6 58.2 63.7 69.2 74.6 80.1 85.6
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 38.7 46.2 52.5 58.9 65.2
150 12.9 15.4 23.6 32.8 42.7 50.4 56.7 63.1 69.4
200 15.2 18.0 26.8 36.4 46.8 54.6 61.0 67.3 73.6
250 17.5 20.6 30.0 40.0 50.9 58.9 65.2 71.5 77.8
5/8 (4) 102 89.7 179.4 400 300 17.5 23.2 33.1 43.7 54.9 63.1 69.4 75.7 82.0 2.0 x Ncbgr
350 17.5 23.2 36.3 47.3 59.0 67.3 73.6 79.9 86.2
400 17.5 23.2 39.4 51.0 63.1 71.5 77.8 84.1 90.4
450 17.5 23.2 42.6 54.6 67.2 75.7 82.0 88.3 94.6
500 17.5 23.2 42.6 58.2 71.2 79.9 86.2 92.5 98.8
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 38.7 49.0 58.7 65.8 72.8
150 12.9 15.4 23.6 32.8 42.7 53.5 63.4 70.5 77.5
200 15.2 18.0 26.8 36.4 46.8 58.0 68.1 75.2 82.2
250 17.5 20.6 30.0 40.0 50.9 62.4 72.8 79.9 86.9
5/8 (4) 102 89.7 179.4 500 300 17.5 23.2 33.1 43.7 54.9 66.9 77.5 84.6 91.6 2.0 x Ncbgr
350 17.5 23.2 36.3 47.3 59.0 71.3 82.2 89.3 96.3
400 17.5 23.2 39.4 51.0 63.1 75.8 86.9 94.0 101.0
450 17.5 23.2 42.6 54.6 67.2 80.3 91.6 98.7 105.7
500 17.5 23.2 42.6 58.2 71.2 84.7 96.3 103.4 110.4
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 38.7 49.0 60.2 72.1 79.8
150 12.9 15.4 23.6 32.8 42.7 53.5 65.0 77.2 84.9
200 15.2 18.0 26.8 36.4 46.8 58.0 69.8 82.4 90.1
250 17.5 20.6 30.0 40.0 50.9 62.4 74.6 87.5 95.2
5/8 (4) 102 89.7 179.4 600 300 17.5 23.2 33.1 43.7 54.9 66.9 79.5 92.7 100.4 2.0 x Ncbgr
350 17.5 23.2 36.3 47.3 59.0 71.3 84.3 97.8 105.5
400 17.5 23.2 39.4 51.0 63.1 75.8 89.1 103.0 110.7
450 17.5 23.2 42.6 54.6 67.2 80.3 93.9 108.1 115.8
500 17.5 23.2 42.6 58.2 71.2 84.7 98.7 113.3 121.0
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 38.7 49.0 60.2 72.1 84.6
150 12.9 15.4 23.6 32.8 42.7 53.5 65.0 77.2 90.1
200 15.2 18.0 26.8 36.4 46.8 58.0 69.8 82.4 95.6
250 17.5 20.6 30.0 40.0 50.9 62.4 74.6 87.5 101.0
5/8 (4) 102 89.7 179.4 675 300 17.5 23.2 33.1 43.7 54.9 66.9 79.5 92.7 106.5 2.0 x Ncbgr
350 17.5 23.2 36.3 47.3 59.0 71.3 84.3 97.8 111.9
400 17.5 23.2 39.4 51.0 63.1 75.8 89.1 103.0 117.4
450 17.5 23.2 42.6 54.6 67.2 80.3 93.9 108.1 122.9
500 17.5 23.2 42.6 58.2 71.2 84.7 98.7 113.3 128.3

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00 s s
25 1.12
30 1.22 V V
35 1.32 s s
40 1.41
45 1.50
50 1.58
c1 c1 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 85
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ Expansion Anchor


Table 18 - Factored resistance for 3 or 6 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
150 X X X X 34.5 39.4 44.3 49.2 54.2
200 X X X 32.8 37.7 42.7 47.6 52.5 57.4
250 X X 31.2 36.1 41.0 46.0 50.9 55.8 60.7
300 29.9 X 34.5 39.4 44.3 49.2 54.2 59.1 64.0
3/4 (3-3/4) 95 135.6 271.2 203 2.0 x Ncbgr
350 33.0 X 37.7 42.7 47.6 52.5 57.4 62.4 67.3
400 33.8 X 41.0 46.0 50.9 55.8 60.7 65.6 70.6
450 33.8 X 44.3 49.2 54.2 59.1 64.0 68.9 73.8
500 33.8 X 44.3 52.5 57.4 62.4 67.3 72.2 77.1
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X X 41.9 47.9 53.9 59.8 65.8
200 X X X 39.9 45.9 51.9 57.9 63.8 69.8
250 X X 32.8 43.9 49.9 55.9 61.8 67.8 73.8
300 29.9 X 36.3 47.9 53.9 59.8 65.8 71.8 77.8
3/4 (3-3/4) 95 135.6 271.2 300 2.0 x Ncbgr
350 33.0 X 39.7 51.9 57.9 63.8 69.8 75.8 81.8
400 33.8 X 43.2 55.9 61.8 67.8 73.8 79.8 85.8
450 33.8 X 46.6 59.8 65.8 71.8 77.8 83.8 89.8
500 33.8 X 46.6 63.8 69.8 75.8 81.8 87.8 93.8
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X X 46.8 55.3 62.2 69.1 76.0
200 X X X 39.9 51.3 59.9 66.8 73.7 80.6
250 X X 32.8 43.9 55.8 64.5 71.4 78.3 85.2
300 29.9 X 36.3 47.9 60.2 69.1 76.0 82.9 89.8
3/4 (3-3/4) 95 135.6 271.2 400 2.0 x Ncbgr
350 33.0 X 39.7 51.9 64.7 73.7 80.6 87.5 94.4
400 33.8 X 43.2 55.9 69.1 78.3 85.2 92.1 99.1
450 33.8 X 46.6 59.8 73.6 82.9 89.8 96.8 103.7
500 33.8 X 46.6 63.8 78.1 87.5 94.4 101.4 108.3
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X X 46.8 58.6 69.5 77.3 85.0
200 X X X 39.9 51.3 63.5 74.7 82.4 90.1
250 X X 32.8 43.9 55.8 68.4 79.8 87.6 95.3
300 29.9 X 36.3 47.9 60.2 73.3 85.0 92.7 100.4
3/4 (3-3/4) 95 135.6 271.2 500 2.0 x Ncbgr
350 33.0 X 39.7 51.9 64.7 78.2 90.1 97.9 105.6
400 33.8 X 43.2 55.9 69.1 83.1 95.3 103.0 110.7
450 33.8 X 46.6 59.8 73.6 88.0 100.4 108.2 115.9
500 33.8 X 46.6 63.8 78.1 92.8 105.6 113.3 121.1
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X X 46.8 58.6 71.3 84.6 93.1
200 X X X 39.9 51.3 63.5 76.5 90.3 98.7
250 X X 32.8 43.9 55.8 68.4 81.8 95.9 104.4
300 29.9 X 36.3 47.9 60.2 73.3 87.1 101.6 110.0
3/4 (3-3/4) 95 135.6 271.2 600 2.0 x Ncbgr
350 33.0 X 39.7 51.9 64.7 78.2 92.4 107.2 115.7
400 33.8 X 43.2 55.9 69.1 83.1 97.6 112.9 121.3
450 33.8 X 46.6 59.8 73.6 88.0 102.9 118.5 127.0
500 33.8 X 46.6 63.8 78.1 92.8 108.2 124.1 132.6
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X X 46.8 58.6 71.3 84.6 98.8
200 X X X 39.9 51.3 63.5 76.5 90.3 104.7
250 X X 32.8 43.9 55.8 68.4 81.8 95.9 110.7
300 29.9 X 36.3 47.9 60.2 73.3 87.1 101.6 116.7
3/4 (3-3/4) 95 135.6 271.2 675 2.0 x Ncbgr
350 33.0 X 39.7 51.9 64.7 78.2 92.4 107.2 122.7
400 33.8 X 43.2 55.9 69.1 83.1 97.6 112.9 128.7
450 33.8 X 46.6 59.8 73.6 88.0 102.9 118.5 134.7
500 33.8 X 46.6 63.8 78.1 92.8 108.2 124.1 140.6

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00 s s
25 1.12
30 1.22 V V
35 1.32 s s
40 1.41
45 1.50
50 1.58
c1 c1 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

86 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ Expansion Anchor 3.0


Table 19 - Factored resistance for 3 or 6 KB-TZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
150 X X X 29.5 34.5 39.4 44.3 49.2 54.2
200 X X 27.9 32.8 37.7 42.7 47.6 52.5 57.4
250 23.6 X 31.2 36.1 41.0 46.0 50.9 55.8 60.7
300 26.5 X 34.5 39.4 44.3 49.2 54.2 59.1 64.0
3/4 (4-3/4) 121 135.6 271.2 203 2.0 x Ncbgr
350 27.3 X 37.7 42.7 47.6 52.5 57.4 62.4 67.3
400 27.3 X 41.0 46.0 50.9 55.8 60.7 65.6 70.6
450 27.3 X 44.3 49.2 54.2 59.1 64.0 68.9 73.8
500 27.3 X 44.3 52.5 57.4 62.4 67.3 72.2 77.1
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X 35.9 41.9 47.9 53.9 59.8 65.8
200 X X 29.4 39.9 45.9 51.9 57.9 63.8 69.8
250 23.6 X 32.8 43.9 49.9 55.9 61.8 67.8 73.8
300 26.5 X 36.3 47.9 53.9 59.8 65.8 71.8 77.8
3/4 (4-3/4) 121 135.6 271.2 300 2.0 x Ncbgr
350 27.3 X 39.7 51.9 57.9 63.8 69.8 75.8 81.8
400 27.3 X 43.2 55.9 61.8 67.8 73.8 79.8 85.8
450 27.3 X 46.6 59.8 65.8 71.8 77.8 83.8 89.8
500 27.3 X 46.6 63.8 69.8 75.8 81.8 87.8 93.8
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X 35.9 46.8 55.3 62.2 69.1 76.0
200 X X 29.4 39.9 51.3 59.9 66.8 73.7 80.6
250 23.6 X 32.8 43.9 55.8 64.5 71.4 78.3 85.2
300 26.5 X 36.3 47.9 60.2 69.1 76.0 82.9 89.8
3/4 (4-3/4) 121 135.6 271.2 400 2.0 x Ncbgr
350 27.3 X 39.7 51.9 64.7 73.7 80.6 87.5 94.4
400 27.3 X 43.2 55.9 69.1 78.3 85.2 92.1 99.1
450 27.3 X 46.6 59.8 73.6 82.9 89.8 96.8 103.7
500 27.3 X 46.6 63.8 78.1 87.5 94.4 101.4 108.3
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X 35.9 46.8 58.6 69.5 77.3 85.0
200 X X 29.4 39.9 51.3 63.5 74.7 82.4 90.1
250 23.6 X 32.8 43.9 55.8 68.4 79.8 87.6 95.3
300 26.5 X 36.3 47.9 60.2 73.3 85.0 92.7 100.4
3/4 (4-3/4) 121 135.6 271.2 500 2.0 x Ncbgr
350 27.3 X 39.7 51.9 64.7 78.2 90.1 97.9 105.6
400 27.3 X 43.2 55.9 69.1 83.1 95.3 103.0 110.7
450 27.3 X 46.6 59.8 73.6 88.0 100.4 108.2 115.9
500 27.3 X 46.6 63.8 78.1 92.8 105.6 113.3 121.1
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X 35.9 46.8 58.6 71.3 84.6 93.1
200 X X 29.4 39.9 51.3 63.5 76.5 90.3 98.7
250 23.6 X 32.8 43.9 55.8 68.4 81.8 95.9 104.4
300 26.5 X 36.3 47.9 60.2 73.3 87.1 101.6 110.0
3/4 (4-3/4) 121 135.6 271.2 600 2.0 x Ncbgr
350 27.3 X 39.7 51.9 64.7 78.2 92.4 107.2 115.7
400 27.3 X 43.2 55.9 69.1 83.1 97.6 112.9 121.3
450 27.3 X 46.6 59.8 73.6 88.0 102.9 118.5 127.0
500 27.3 X 46.6 63.8 78.1 92.8 108.2 124.1 132.6
c1 - edge distance (mm)
mm cmin 100 150 200 250 300 350 400 450
150 X X X 35.9 46.8 58.6 71.3 84.6 98.8
200 X X 29.4 39.9 51.3 63.5 76.5 90.3 104.7
250 23.6 X 32.8 43.9 55.8 68.4 81.8 95.9 110.7
300 26.5 X 36.3 47.9 60.2 73.3 87.1 101.6 116.7
3/4 (4-3/4) 121 135.6 271.2 675 2.0 x Ncbgr
350 27.3 X 39.7 51.9 64.7 78.2 92.4 107.2 122.7
400 27.3 X 43.2 55.9 69.1 83.1 97.6 112.9 128.7
450 27.3 X 46.6 59.8 73.6 88.0 102.9 118.5 134.7
500 27.3 X 46.6 63.8 78.1 92.8 108.2 124.1 140.6

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00 s s
25 1.12
30 1.22 V V
35 1.32 s s
40 1.41
45 1.50
50 1.58
c1 c1 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊxÇ°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 87
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor


Notes for Tension Tables (Stainless Steel Only) Notes for Shear Tables (Stainless Steel Only)

£ÊœÀʜ̅iÀÊVœ˜VÀiÌiÊÃÌÀi˜}̅Ã]ʓՏ̈«ÞÊNcbr and Npr by 1 Design strengths in table are for anchors near one edge
corresponding influence of concrete strength factor, fb. only. The values do not apply where the distance to an
edge, measured perpendicular to c1, is less than 1.5c1.
ÓÊœÀÊ
>ÀLœ˜Ê-Ìii]ÊÕÃiÊ ‡/<ÊÌ>Lið
Shear force is assumed to act perpendicular, towards the
3 Design strengths in the table are based on resistance edge with no eccentricity.
“œ`ˆvˆV>̈œ˜Êv>V̜ÀÊ,]ʜvÊ-iV̈œ˜Ê °x°{°Ê>V̜Ài`ÊÌi˜ÃˆiÊ
ÓÊœÀʜ̅iÀÊVœ˜VÀiÌiÊÃÌÀi˜}̅Ã]ʓՏ̈«ÞÊVcbr by corresponding
load Nf must be computed from the load combinations
influence of concrete strength factor, fb.
referenced in Clause 8.3.2. Design strengths for concrete
LÀi>ŽœÕÌ]ÊNbr, pullout, Npr, and sideface blowout, Nsbr ÎÊœÀÊ
>ÀLœ˜Ê-Ìii]ÊÕÃiÊ ‡/<ÊÌ>Lið
are based on Condition B. Where supplementary
4 Design strengths in the table are based on resistance
reinforcement is provided to satisfy Condition A, design
“œ`ˆvˆV>̈œ˜Êv>V̜ÀÊ,]ʜvÊ-iV̈œ˜Ê °x°{°Ê>V̜Ài`ÊÅi>ÀÊ
strengths for Nbr and Nsbr may be increased by the ratio
load Vf must be computed from the load combinations
œvÊ, condition A ÊÉÊ, condition B . This increase does not apply to
referenced in Clause 8.3.2. Design strengths for
pullout strength, Npr.
Vœ˜VÀiÌiÊLÀi>ŽœÕÌ]ÊVbr, are based on Condition B. Where
{Ê7…iÀiÊ>˜>ÞÈÃʈ˜`ˆV>ÌiÃÊ̅>ÌÊ̅iÀiÊ܈ÊLiʘœÊVÀ>VŽˆ˜}Ê>ÌÊ supplementary reinforcement is provided to satisfy
service load levels (ft < fr) in the region of the anchor, the Condition A, this design may be increased by the ratio
`iÈ}˜ÊÃÌÀi˜}̅ÃÊvœÀÊVœ˜VÀiÌiÊLÀi>ŽœÕÌʈ˜ÊÌi˜Ãˆœ˜]ÊNbr, may œvÊ, condition AÊÉÊ, condition B . This increase does not apply to
be increased by #c,N. See Section D.6.2.6. pryout capacities, for which condition B is always assumed.

xÊ7…iÀiÊ>˜>ÞÈÃʈ˜`ˆV>ÌiÃÊ̅>ÌÊ̅iÀiÊ܈ÊLiʘœÊVÀ>VŽˆ˜}Ê>ÌÊ xÊ7…iÀiÊ>˜>ÞÈÃʈ˜`ˆV>ÌiÃÊ̅>ÌÊ̅iÀiÊ܈ÊLiʘœÊVÀ>VŽˆ˜}Ê>ÌÊ
service load levels (ft < fr) in the region of the anchor, the service load levels (ft < fr) in the region of the anchor, the
design strengths for concrete pullout in tension, Npr, may be `iÈ}˜ÊÃÌÀi˜}̅ÃÊvœÀÊVœ˜VÀiÌiÊLÀi>ŽœÕÌʈ˜ÊÅi>À]ÊVbr, may be
increased by 40%. See Section D.6.3.6. increased by 40%. See Section D.7.2.7.

ÈÊ/…iÊ`iÈ}˜ÊÃÌÀi˜}̅ÃÊvœÀÊVœ˜VÀiÌiÊLÀi>ŽœÕÌ]ÊVbr, are based


on the shear load being applied perpendicular towards
the edge. If the load is applied parallel to the edge, the
strengths may be increased 100%. See Section D.7.2.1c.

7 Linear interpolation for intermediate values of edge


distance, c1 is permissible.

88 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt RTZ Expansion Anchor 3.0


Table 1 - Factored resistance for Single KB-RTZ anchor subject to Tensile Loads in Cracked Concrete (f ' c = 20 MPa)

Minimum
Min. Nsr - Tension
Embedment Edge 1,3,4 Npr - Nsbr - Sideface
Size Concrete Strength of Ncbr - Tension Breakout (kN)
Depth, hef Distance Pullout1,5 Blowout
Thickness, h
cmin Anchor2

mm mm mm kN c1 - edge distance (mm) kN kN


cmin 100 150 200 250 300 350 400 450

3/8 (2) 51 127 64 18.1 6.5 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.3 N/A
1/2 (2) 51 152 73 35.1 10.2 10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6 9.9 N/A
1/2 (3-1/4) 83 203 54 35.1 9.2 13.1 15.4 15.4 15.4 15.4 15.4 15.4 15.4 N/A N/A
5/8 (3-1/8) 79 127 83 56.4 11.1 12.6 14.3 14.3 14.3 14.3 14.3 14.3 14.3 N/A N/A
5/8 (4) 102 152 60 56.4 11.9 15.5 20.6 21.0 21.0 21.0 21.0 21.0 21.0 18.1 N/A
3/4 (3-3/4) 95 152 108 72.7 21.9 X 26.9 26.9 26.9 26.9 26.9 26.9 26.9 25.2 N/A
3/4 (4-3/4) 121 203 102 72.7 18.4 X 23.4 27.1 27.1 27.1 27.1 27.1 27.1 N/A N/A

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22
35 1.32
40 1.41
45 1.50
50 1.58 c1
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 89
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor


Table 2 - Factored resistance for 2 KB-RTZ anchors subject to Tensile Loads in Cracked Concrete (f 'c = 20 MPa)
Nsr - Tension
Spacing, Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Ncbgr - Tension Breakout of Group1,3,4 (kN)
s Group1,5 of Group
Anchor Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
64 100 150 200 250 300 350 400 450
100 X 12.3 12.3 12.3 12.3 12.3 12.3 12.3 12.3
150 12.8 14.7 14.7 14.7 14.7 14.7 14.7 14.7 14.7
200 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
250 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
3/8 (2) 51 127 36.2 300 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.6 N/A
350 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
400 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
450 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
500 12.9 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8
cmin
73 100 150 200 250 300 350 400 450
100 X 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5
150 20.2 21.0 21.0 21.0 21.0 21.0 21.0 21.0 21.0
200 20.4 21.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2
250 20.4 21.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2
1/2 (2) 51 152 70.1 300 20.4 21.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2 19.8 N/A
350 20.4 21.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2
400 20.4 21.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2
450 20.4 21.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2
500 20.4 21.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2
cmin
54 100 150 200 250 300 350 400 450
100 X 18.3 21.6 21.6 21.6 21.6 21.6 21.6 21.6
150 14.7 20.9 24.7 24.7 24.7 24.7 24.7 24.7 24.7
200 16.5 23.5 27.7 27.7 27.7 27.7 27.7 27.7 27.7
250 18.3 26.1 30.8 30.8 30.8 30.8 30.8 30.8 30.8
1/2 (3-1/4) 83 203 70.1 300 18.3 26.1 30.8 30.8 30.8 30.8 30.8 30.8 30.8 N/A N/A
350 18.3 26.1 30.8 30.8 30.8 30.8 30.8 30.8 30.8
400 18.3 26.1 30.8 30.8 30.8 30.8 30.8 30.8 30.8
450 18.3 26.1 30.8 30.8 30.8 30.8 30.8 30.8 30.8
500 18.3 26.1 30.8 30.8 30.8 30.8 30.8 30.8 30.8
cmin
83 100 150 200 250 300 350 400 450
100 X 17.9 20.3 20.3 20.3 20.3 20.3 20.3 20.3
150 18.1 20.5 23.3 23.3 23.3 23.3 23.3 23.3 23.3
200 20.4 23.2 26.3 26.3 26.3 26.3 26.3 26.3 26.3
250 22.1 25.1 28.6 28.6 28.6 28.6 28.6 28.6 28.6
5/8 (3-1/8) 79 127 112.8 300 22.1 25.1 28.6 28.6 28.6 28.6 28.6 28.6 28.6 N/A N/A
350 22.1 25.1 28.6 28.6 28.6 28.6 28.6 28.6 28.6
400 22.1 25.1 28.6 28.6 28.6 28.6 28.6 28.6 28.6
450 22.1 25.1 28.6 28.6 28.6 28.6 28.6 28.6 28.6
500 22.1 25.1 28.6 28.6 28.6 28.6 28.6 28.6 28.6
cmin
60 100 150 200 250 300 350 400 450
100 X 20.6 27.4 27.8 27.8 27.8 27.8 27.8 27.8
150 17.8 23.1 30.7 31.2 31.2 31.2 31.2 31.2 31.2
200 19.7 25.7 34.1 34.7 34.7 34.7 34.7 34.7 34.7
250 21.7 28.2 37.5 38.1 38.1 38.1 38.1 38.1 38.1
5/8 (4) 102 152 112.8 300 23.6 30.8 40.9 41.5 41.5 41.5 41.5 41.5 41.5 36.2 N/A
350 23.9 31.1 41.3 41.9 41.9 41.9 41.9 41.9 41.9
400 23.9 31.1 41.3 41.9 41.9 41.9 41.9 41.9 41.9
450 23.9 31.1 41.3 41.9 41.9 41.9 41.9 41.9 41.9
500 23.9 31.1 41.3 41.9 41.9 41.9 41.9 41.9 41.9
cmin
108 100 150 200 250 300 350 400 450
100 X X X X X X X X X
150 X X X X 41.1 41.1 41.1 41.1 41.1
200 X X X 45.8 45.8 45.8 45.8 45.8 45.8
250 X X 50.5 50.5 50.5 50.5 50.5 50.5 50.5
3/4 (3-3/4) 95 152 145.5 300 43.9 X 53.8 53.8 53.8 53.8 53.8 53.8 53.8 50.4 N/A
350 43.9 X 53.8 53.8 53.8 53.8 53.8 53.8 53.8
400 43.9 X 53.8 53.8 53.8 53.8 53.8 53.8 53.8
450 43.9 X 53.8 53.8 53.8 53.8 53.8 53.8 53.8
500 43.9 X 53.8 53.8 53.8 53.8 53.8 53.8 53.8
cmin
102 120 150 200 250 300 350 400 450
100 X X X X X X X X X
150 X X 33.1 38.3 38.3 38.3 38.3 38.3 38.3
200 X X 36.4 42.0 42.0 42.0 42.0 42.0 42.0
250 31.0 X 39.6 45.7 45.7 45.7 45.7 45.7 45.7
3/4 (4-3/4) 121 203 145.5 300 33.6 X 42.8 49.5 49.5 49.5 49.5 49.5 49.5 N/A N/A
350 36.1 X 46.1 53.2 53.2 53.2 53.2 53.2 53.2
400 36.7 X 49.3 54.2 54.2 54.2 54.2 54.2 54.2
450 36.7 X 51.3 54.2 54.2 54.2 54.2 54.2 54.2
500 36.7 X 51.3 54.2 54.2 54.2 54.2 54.2 54.2
Notes:
A. For eccentric loading, multiply Ncbgr by the modification factor for eccentrically loaded anchor groups,  ec,N as per Section D.6.2.4.
B. If anchors are affected by more than one edge distance use formulas to calculate Concrete Resistance

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12
s
30 1.22
35 1.32
40 1.41
45 1.50
50 1.58 c1
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

90 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt RTZ Expansion Anchor 3.0


Table 3 - Factored resistance for 4 KB-RTZ anchors subject to Tensile Loads in Cracked Concrete (f 'c = 20 MPa)
Nsr - Tension
Spacing, Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Ncbgr - Tension Breakout of Group1,3,4 (kN) 1,5
s Group of Group
Anchor Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
64 100 150 200 250 300 350 400 450
100 X 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3
150 26.5 29.1 29.1 29.1 29.1 29.1 29.1 29.1 29.1
200 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
250 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
3/8 (2) 51 127 72.5 300 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.2 N/A
350 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
400 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
450 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
500 27.0 29.6 29.6 29.6 29.6 29.6 29.6 29.6 29.6
cmin
73 100 150 200 250 300 350 400 450
100 X 28.9 28.9 28.9 28.9 28.9 28.9 28.9 28.9
150 40.5 41.5 41.5 41.5 41.5 41.5 41.5 41.5 41.5
200 41.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3
250 41.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3
1/2 (2) 51 152 140.2 300 41.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3 39.6 N/A
350 41.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3
400 41.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3
450 41.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3
500 41.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3
cmin
54 100 150 200 250 300 350 400 450
100 X 26.4 30.2 30.2 30.2 30.2 30.2 30.2 30.2
150 27.0 34.9 39.5 39.5 39.5 39.5 39.5 39.5 39.5
200 35.0 44.5 50.0 50.0 50.0 50.0 50.0 50.0 50.0
250 43.9 55.1 61.5 61.5 61.5 61.5 61.5 61.5 61.5
1/2 (3-1/4) 83 203 140.2 300 43.9 55.1 61.5 61.5 61.5 61.5 61.5 61.5 61.5 N/A N/A
350 43.9 55.1 61.5 61.5 61.5 61.5 61.5 61.5 61.5
400 43.9 55.1 61.5 61.5 61.5 61.5 61.5 61.5 61.5
450 43.9 55.1 61.5 61.5 61.5 61.5 61.5 61.5 61.5
500 43.9 55.1 61.5 61.5 61.5 61.5 61.5 61.5 61.5
cmin
83 100 150 200 250 300 350 400 450
100 X 26.0 28.9 28.9 28.9 28.9 28.9 28.9 28.9
150 31.5 34.6 38.1 38.1 38.1 38.1 38.1 38.1 38.1
200 40.6 44.3 48.6 48.6 48.6 48.6 48.6 48.6 48.6
250 48.1 52.3 57.2 57.2 57.2 57.2 57.2 57.2 57.2
5/8 (3-1/8) 79 127 225.6 300 48.1 52.3 57.2 57.2 57.2 57.2 57.2 57.2 57.2 N/A N/A
350 48.1 52.3 57.2 57.2 57.2 57.2 57.2 57.2 57.2
400 48.1 52.3 57.2 57.2 57.2 57.2 57.2 57.2 57.2
450 48.1 52.3 57.2 57.2 57.2 57.2 57.2 57.2 57.2
500 48.1 52.3 57.2 57.2 57.2 57.2 57.2 57.2 57.2
cmin
60 100 150 200 250 300 350 400 450
100 X 28.7 36.4 36.9 36.9 36.9 36.9 36.9 36.9
150 30.3 36.9 46.0 46.5 46.5 46.5 46.5 46.5 46.5
200 38.3 46.0 56.6 57.3 57.3 57.3 57.3 57.3 57.3
250 47.1 56.1 68.4 69.2 69.2 69.2 69.2 69.2 69.2
5/8 (4) 102 152 225.6 300 56.9 67.2 81.3 82.2 82.2 82.2 82.2 82.2 82.2 72.4 N/A
350 58.1 68.6 82.9 83.8 83.8 83.8 83.8 83.8 83.8
400 58.1 68.6 82.9 83.8 83.8 83.8 83.8 83.8 83.8
450 58.1 68.6 82.9 83.8 83.8 83.8 83.8 83.8 83.8
500 58.1 68.6 82.9 83.8 83.8 83.8 83.8 83.8 83.8
cmin
108 100 150 200 250 300 350 400 450
100 X X X X X X X X X
150 X X X X 62.7 62.7 62.7 62.7 62.7
200 X X X 77.9 77.9 77.9 77.9 77.9 77.9
250 X X 94.8 94.8 94.8 94.8 94.8 94.8 94.8
3/4 (3-3/4) 95 152 290.9 300 93.8 X 107.7 107.7 107.7 107.7 107.7 107.7 107.7 100.8 N/A
350 93.8 X 107.7 107.7 107.7 107.7 107.7 107.7 107.7
400 93.8 X 107.7 107.7 107.7 107.7 107.7 107.7 107.7
450 93.8 X 107.7 107.7 107.7 107.7 107.7 107.7 107.7
500 93.8 X 107.7 107.7 107.7 107.7 107.7 107.7 107.7
cmin
102 120 150 200 250 300 350 400 450
100 X X X X X X X X X
150 X X 48.1 54.1 54.1 54.1 54.1 54.1 54.1
200 X X 58.3 65.1 65.1 65.1 65.1 65.1 65.1
250 58.4 X 69.5 77.2 77.2 77.2 77.2 77.2 77.2
3/4 (4-3/4) 121 203 290.0 300 69.1 X 81.6 90.3 90.3 90.3 90.3 90.3 90.3 N/A N/A
350 80.6 X 94.7 104.5 104.5 104.5 104.5 104.5 104.5
400 83.8 X 98.2 108.3 108.3 108.3 108.3 108.3 108.3
450 83.8 X 98.2 108.3 108.3 108.3 108.3 108.3 108.3
500 83.8 X 98.2 108.3 108.3 108.3 108.3 108.3 108.3
Notes:
A. For eccentric loading, multiply Ncbgr by the modification factor for eccentrically loaded anchor groups,  ec,N as per Section D.6.2.4.
B. If anchors are affected by more than one edge distance use formulas to calculate Concrete Resistance

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12 s
30 1.22
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 91
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor


Table 4 - Factored resistance for 6 KB-RTZ anchors subject to Tensile Loads in Cracked Concrete (f'c = 20 MPa)
Nsr - Tension
Spacing, Npr - Pullout of Nsbgr - Sideface Blowout
Size hef hmin Strength of Ncbgr - Tension Breakout of Group1,3,4 (kN)
s Group1,2 of Group
Anchor Group2
mm mm kN mm c1 - edge distance (mm) kN kN
cmin
64 100 150 200 250 300 350 400 450
100 X 28.3 28.3 28.3 28.3 28.3 28.3 28.3 28.3
150 39.6 43.5 43.5 43.5 43.5 43.5 43.5 43.5 43.5
200 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
250 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
3/8 (2) 51 127 108.7 300 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5 43.8 N/A
350 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
400 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
450 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
500 40.6 44.5 44.5 44.5 44.5 44.5 44.5 44.5 44.5
cmin
73 100 150 200 250 300 350 400 450
100 X 40.4 40.4 40.4 40.4 40.4 40.4 40.4 40.4
150 60.5 62.1 62.1 62.1 62.1 62.1 62.1 62.1 62.1
200 61.9 63.5 63.5 63.5 63.5 63.5 63.5 63.5 63.5
250 61.9 63.5 63.5 63.5 63.5 63.5 63.5 63.5 63.5
1/2 (2) 51 152 210.3 300 61.9 63.5 63.5 63.5 63.5 63.5 63.5 63.5 63.5 59.4 N/A
350 61.9 63.5 63.5 63.5 63.5 63.5 63.5 63.5 63.5
400 61.9 63.5 63.5 63.5 63.5 63.5 63.5 63.5 63.5
450 61.9 63.5 63.5 63.5 63.5 63.5 63.5 63.5 63.5
500 61.9 63.5 63.5 63.5 63.5 63.5 63.5 63.5 63.5
cmin
54 100 150 200 250 300 350 400 450
100 X 34.0 38.9 38.9 38.9 38.9 38.9 38.9 38.9
150 37.2 48.0 54.4 54.4 54.4 54.4 54.4 54.4 54.4
200 50.6 64.3 72.3 72.3 72.3 72.3 72.3 72.3 72.3
250 65.8 82.6 92.3 92.3 92.3 92.3 92.3 92.3 92.3
1/2 (3-1/4) 83 203 210.3 300 65.8 82.6 92.3 92.3 92.3 92.3 92.3 92.3 92.3 N/A N/A
350 65.8 82.6 92.3 92.3 92.3 92.3 92.3 92.3 92.3
400 65.8 82.6 92.3 92.3 92.3 92.3 92.3 92.3 92.3
450 65.8 82.6 92.3 92.3 92.3 92.3 92.3 92.3 92.3
500 65.8 82.6 92.3 92.3 92.3 92.3 92.3 92.3 92.3
cmin
83 100 150 200 250 300 350 400 450
100 X 33.7 37.5 37.5 37.5 37.5 37.5 37.5 37.5
150 43.7 48.0 52.9 52.9 52.9 52.9 52.9 52.9 52.9
200 59.2 64.6 70.8 70.8 70.8 70.8 70.8 70.8 70.8
250 72.2 78.5 85.7 85.7 85.7 85.7 85.7 85.7 85.7
5/8 (3-1/8) 79 127 338.4 300 72.2 78.5 85.7 85.7 85.7 85.7 85.7 85.7 85.7 N/A N/A
350 72.2 78.5 85.7 85.7 85.7 85.7 85.7 85.7 85.7
400 72.2 78.5 85.7 85.7 85.7 85.7 85.7 85.7 85.7
450 72.2 78.5 85.7 85.7 85.7 85.7 85.7 85.7 85.7
500 72.2 78.5 85.7 85.7 85.7 85.7 85.7 85.7 85.7
cmin
60 100 150 200 250 300 350 400 450
100 X 35.8 45.4 46.0 46.0 46.0 46.0 46.0 46.0
150 40.3 49.0 61.1 61.9 61.9 61.9 61.9 61.9 61.9
200 53.4 64.2 79.0 80.0 80.0 80.0 80.0 80.0 80.0
250 68.3 81.3 99.2 100.3 100.3 100.3 100.3 100.3 100.3
5/8 (4) 102 152 338.4 300 85.1 100.5 121.6 122.9 122.9 122.9 122.9 122.9 122.9 108.6 N/A
350 87.2 102.9 124.4 125.8 125.8 125.8 125.8 125.8 125.8
400 87.2 102.9 124.4 125.8 125.8 125.8 125.8 125.8 125.8
450 87.2 102.9 124.4 125.8 125.8 125.8 125.8 125.8 125.8
500 87.2 102.9 124.4 125.8 125.8 125.8 125.8 125.8 125.8
cmin
108 100 150 200 250 300 350 400 450
100 X X X X X X X X X
150 X X X X 84.3 84.3 84.3 84.3 84.3
200 X X X 110.1 110.1 110.1 110.1 110.1 110.1
250 X X 139.2 139.2 139.2 139.2 139.2 139.2 139.2
3/4 (3-3/4) 95 152 436.4 300 140.7 X 161.5 161.5 161.5 161.5 161.5 161.5 161.5 151.2 N/A
350 140.7 X 161.5 161.5 161.5 161.5 161.5 161.5 161.5
400 140.7 X 161.5 161.5 161.5 161.5 161.5 161.5 161.5
450 140.7 X 161.5 161.5 161.5 161.5 161.5 161.5 161.5
500 140.7 X 161.5 161.5 161.5 161.5 161.5 161.5 161.5
cmin
102 120 150 200 250 300 350 400 450
100 X X X X X X X X X
150 X X 62.2 69.9 69.9 69.9 69.9 69.9 69.9
200 X X 79.0 88.3 88.3 88.3 88.3 88.3 88.3
250 82.2 X 97.8 108.7 108.7 108.7 108.7 108.7 108.7
3/4 (4-3/4) 121 203 436.4 300 100.3 X 118.5 131.2 131.2 131.2 131.2 131.2 131.2 N/A N/A
350 120.2 X 141.1 155.8 155.8 155.8 155.8 155.8 155.8
400 125.7 X 147.4 162.5 162.5 162.5 162.5 162.5 162.5
450 125.7 X 147.4 162.5 162.5 162.5 162.5 162.5 162.5
500 125.7 X 147.4 162.5 162.5 162.5 162.5 162.5 162.5
Notes:
A. For eccentric loading, multiply Ncbgr by the modification factor for eccentrically loaded anchor groups, ec,N as per Section D.6.2.4.
B. If anchors are affected by more than one edge distance use formulas to calculate Concrete Resistance

Influence of Concrete Strength, fb


f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s
35 1.32
40 1.41
45 1.50
50 1.58 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°
c1 s

92 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt RTZ Expansion Anchor 3.0


Table 5 - Factored resistance for Single KB-RTZ anchor subject to Shear Loads in Cracked Concrete (f'c = 20 MPa)

Vsr - Shear
Concrete Vcpr - Pryout
Size hef Strength of Vcbr - Shear Breakout (kN) 1,2,4,5,6,7
Thickness, h Resistance
Anchor3
c1 - edge distance (mm) kcp X Ncbr
mm kN mm cmin 100 150 200 250 300 350 400 450 kN
127 3.1 5.5 8.2 11.0 13.7 16.5 19.2 22.0 24.7
203 3.1 6.0 10.4 13.9 17.4 20.8 24.3 27.8 31.2
300 3.1 6.0 11.0 16.9 21.1 25.3 29.5 33.8 38.0
3/8 (2) 51 13.8 400 3.1 6.0 11.0 16.9 23.6 29.2 34.1 39.0 43.9 1.0 x Ncbr
500 3.1 6.0 11.0 16.9 23.6 31.0 38.1 43.6 49.0
600 3.1 6.0 11.0 16.9 23.6 31.0 39.1 47.8 53.7
675 3.1 6.0 11.0 16.9 23.6 31.0 39.1 47.8 57.0
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
152 4.3 6.9 10.4 13.9 17.4 20.8 24.3 27.8 31.3
203 4.3 6.9 12.0 16.1 20.1 24.1 28.1 32.1 36.1
300 4.3 6.9 12.7 19.5 24.4 29.3 34.2 39.0 43.9
1/2 (2) 51 19.5 400 4.3 6.9 12.7 19.5 27.3 33.8 39.4 45.1 50.7 1.0 x Ncbr
500 4.3 6.9 12.7 19.5 27.3 35.9 44.1 50.4 56.7
600 4.3 6.9 12.7 19.5 27.3 35.9 45.2 55.2 62.1
675 4.3 6.9 12.7 19.5 27.3 35.9 45.2 55.2 65.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
203 2.7 6.9 12.0 16.1 20.1 24.1 28.1 32.1 36.1
300 2.7 6.9 12.7 19.5 24.4 29.3 34.2 39.0 43.9
400 2.7 6.9 12.7 19.5 27.3 33.8 39.4 45.1 50.7 2.0 x Ncbr
1/2 (3-1/4) 83 19.5
500 2.7 6.9 12.7 19.5 27.3 35.9 44.1 50.4 56.7
600 2.7 6.9 12.7 19.5 27.3 35.9 45.2 55.2 62.1
675 2.7 6.9 12.7 19.5 27.3 35.9 45.2 55.2 65.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
127 5.8 7.1 10.7 14.2 17.8 21.3 24.9 28.4 32.0
203 5.8 7.7 13.5 18.0 22.5 27.0 31.4 35.9 40.4
300 5.8 7.7 14.2 21.8 27.3 32.8 38.2 43.7 49.1
5/8 (3-1/8) 79 33.6 400 5.8 7.7 14.2 21.8 30.5 37.8 44.1 50.4 56.7 2.0 x Ncbr
500 5.8 7.7 14.2 21.8 30.5 40.1 49.3 56.4 63.4
600 5.8 7.7 14.2 21.8 30.5 40.1 50.6 61.8 69.5
675 5.8 7.7 14.2 21.8 30.5 40.1 50.6 61.8 73.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
152 3.6 7.7 11.7 15.5 19.4 23.3 27.2 31.1 35.0
203 3.6 7.7 13.5 18.0 22.5 27.0 31.4 35.9 40.4
300 3.6 7.7 14.2 21.8 27.3 32.8 38.2 43.7 49.1
5/8 (4) 102 33.6 400 3.6 7.7 14.2 21.8 30.5 37.8 44.1 50.4 56.7 2.0 x Ncbr
500 3.6 7.7 14.2 21.8 30.5 40.1 49.3 56.4 63.4
600 3.6 7.7 14.2 21.8 30.5 40.1 50.6 61.8 69.5
675 3.6 7.7 14.2 21.8 30.5 40.1 50.6 61.8 73.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
152 9.2 X 12.8 17.0 21.3 25.6 29.8 34.1 38.3
203 9.5 X 14.8 19.7 24.6 29.5 34.5 39.4 44.3
300 9.5 X 15.5 23.9 29.9 35.9 41.9 47.9 53.9
3/4 (3-3/4) 95 41.4 400 9.5 X 15.5 23.9 33.5 41.5 48.4 55.3 62.2 2.0 x Ncbr
500 9.5 X 15.5 23.9 33.5 44.0 54.1 61.8 69.5
600 9.5 X 15.5 23.9 33.5 44.0 55.4 67.7 76.2
675 9.5 X 15.5 23.9 33.5 44.0 55.4 67.7 80.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
127 7.9 X 11.7 15.6 19.5 23.4 27.3 31.2 35.0
203 8.7 X 14.8 19.7 24.6 29.5 34.5 39.4 44.3
300 8.7 X 15.5 23.9 29.9 35.9 41.9 47.9 53.9
3/4 (4-3/4) 121 41.4 400 8.7 X 15.5 23.9 33.5 41.5 48.4 55.3 62.2 2.0 x Ncbr
500 8.7 X 15.5 23.9 33.5 44.0 54.1 61.8 69.5
600 8.7 X 15.5 23.9 33.5 44.0 55.4 67.7 76.2
675 8.7 X 15.5 23.9 33.5 44.0 55.4 67.7 80.8

Influence of Concrete Strength, fb


f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 V
35 1.32
40 1.41
45 1.50
50 1.58
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 93
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor


Table 6 - Factored resistance for 2 or 4 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 7.3 10.1 12.8 15.6 18.3 21.1 23.8 26.5
150 5.4 8.2 11.0 13.7 16.5 19.2 22.0 24.7 27.5
200 6.1 9.2 11.9 14.6 17.4 20.1 22.9 25.6 28.4
250 6.1 10.1 12.8 15.6 18.3 21.1 23.8 26.5 29.3
3/8 (2) 51 27.6 55.2 127 300 6.1 11.0 13.7 16.5 19.2 22.0 24.7 27.5 30.2 1.0 x Ncbgr
350 6.1 11.0 14.6 17.4 20.1 22.9 25.6 28.4 31.1
400 6.1 11.0 15.6 18.3 21.1 23.8 26.5 29.3 32.0
450 6.1 11.0 16.5 19.2 22.0 24.7 27.5 30.2 33.0
500 6.1 11.0 16.5 20.1 22.9 25.6 28.4 31.1 33.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 8.0 12.7 16.2 19.7 23.1 26.6 30.1 33.6
150 5.4 9.0 13.9 17.4 20.8 24.3 27.8 31.2 34.7
200 6.1 9.9 15.0 18.5 22.0 25.5 28.9 32.4 35.9
250 6.1 10.9 16.2 19.7 23.1 26.6 30.1 33.6 37.0
3/8 (2) 51 27.6 55.2 203 300 6.1 11.9 17.4 20.8 24.3 27.8 31.2 34.7 38.2 1.0 x Ncbgr
350 6.1 11.9 18.5 22.0 25.5 28.9 32.4 35.9 39.4
400 6.1 11.9 19.7 23.1 26.6 30.1 33.6 37.0 40.5
450 6.1 11.9 20.8 24.3 27.8 31.2 34.7 38.2 41.7
500 6.1 11.9 20.8 25.5 28.9 32.4 35.9 39.4 42.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 8.0 13.4 19.7 23.9 28.1 32.4 36.6 40.8
150 5.4 9.0 14.6 21.1 25.3 29.5 33.8 38.0 42.2
200 6.1 9.9 15.8 22.5 26.7 31.0 35.2 39.4 43.6
250 6.1 10.9 17.1 23.9 28.1 32.4 36.6 40.8 45.0
3/8 (2) 51 27.6 55.2 300 300 6.1 11.9 18.3 25.3 29.5 33.8 38.0 42.2 46.4 1.0 x Ncbgr
350 6.1 11.9 19.5 26.7 31.0 35.2 39.4 43.6 47.8
400 6.1 11.9 20.7 28.1 32.4 36.6 40.8 45.0 49.2
450 6.1 11.9 21.9 29.5 33.8 38.0 42.2 46.4 50.7
500 6.1 11.9 21.9 31.0 35.2 39.4 43.6 47.8 52.1
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 8.0 13.4 19.7 26.7 32.5 37.4 42.2 47.1
150 5.4 9.0 14.6 21.1 28.3 34.1 39.0 43.9 48.7
200 6.1 9.9 15.8 22.5 29.9 35.7 40.6 45.5 50.4
250 6.1 10.9 17.1 23.9 31.5 37.4 42.2 47.1 52.0
3/8 (2) 51 27.6 55.2 400 300 6.1 11.9 18.3 25.3 33.0 39.0 43.9 48.7 53.6 1.0 x Ncbgr
350 6.1 11.9 19.5 26.7 34.6 40.6 45.5 50.4 55.2
400 6.1 11.9 20.7 28.1 36.2 42.2 47.1 52.0 56.9
450 6.1 11.9 21.9 29.5 37.8 43.9 48.7 53.6 58.5
500 6.1 11.9 21.9 31.0 39.3 45.5 50.4 55.2 60.1
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 8.0 13.4 19.7 26.7 34.5 41.8 47.2 52.7
150 5.4 9.0 14.6 21.1 28.3 36.2 43.6 49.0 54.5
200 6.1 9.9 15.8 22.5 29.9 37.9 45.4 50.9 56.3
250 6.1 10.9 17.1 23.9 31.5 39.6 47.2 52.7 58.1
3/8 (2) 51 27.6 55.2 500 300 6.1 11.9 18.3 25.3 33.0 41.4 49.0 54.5 59.9 1.0 x Ncbgr
350 6.1 11.9 19.5 26.7 34.6 43.1 50.9 56.3 61.8
400 6.1 11.9 20.7 28.1 36.2 44.8 52.7 58.1 63.6
450 6.1 11.9 21.9 29.5 37.8 46.5 54.5 59.9 65.4
500 6.1 11.9 21.9 31.0 39.3 48.2 56.3 61.8 67.2
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 8.0 13.4 19.7 26.7 34.5 42.8 51.7 57.7
150 5.4 9.0 14.6 21.1 28.3 36.2 44.7 53.7 59.7
200 6.1 9.9 15.8 22.5 29.9 37.9 46.5 55.7 61.7
250 6.1 10.9 17.1 23.9 31.5 39.6 48.4 57.7 63.7
3/8 (2) 51 27.6 55.2 600 300 6.1 11.9 18.3 25.3 33.0 41.4 50.3 59.7 65.7 1.0 x Ncbgr
350 6.1 11.9 19.5 26.7 34.6 43.1 52.1 61.7 67.7
400 6.1 11.9 20.7 28.1 36.2 44.8 54.0 63.7 69.6
450 6.1 11.9 21.9 29.5 37.8 46.5 55.8 65.7 71.6
500 6.1 11.9 21.9 31.0 39.3 48.2 57.7 67.7 73.6

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

94 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt RTZ Expansion Anchor 3.0


Table 6 - Factored resistance for 2 or 4 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 8.0 13.4 19.7 26.7 34.5 42.8 51.7 61.2
150 5.4 9.0 14.6 21.1 28.3 36.2 44.7 53.7 63.3
200 6.1 9.9 15.8 22.5 29.9 37.9 46.5 55.7 65.4
250 6.1 10.9 17.1 23.9 31.5 39.6 48.4 57.7 67.5
3/8 (2) 51 27.6 55.2 675 300 6.1 11.9 18.3 25.3 33.0 41.4 50.3 59.7 69.6 1.0 x Ncbgr
350 6.1 11.9 19.5 26.7 34.6 43.1 52.1 61.7 71.8
400 6.1 11.9 20.7 28.1 36.2 44.8 54.0 63.7 73.9
450 6.1 11.9 21.9 29.5 37.8 46.5 55.8 65.7 76.0
500 6.1 11.9 21.9 31.0 39.3 48.2 57.7 67.7 78.1

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 95
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor


Table 7 - Factored resistance for 2 or 4 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 9.2 12.7 16.2 19.7 23.2 26.6 30.1 33.6
150 7.3 10.4 13.9 17.4 20.8 24.3 27.8 31.3 34.7
200 8.2 11.5 15.1 18.5 22.0 25.5 28.9 32.4 35.9
250 8.6 12.7 16.2 19.7 23.2 26.6 30.1 33.6 37.1
1/2 (2) 51 39.0 78.0 152 300 8.6 13.8 17.4 20.8 24.3 27.8 31.3 34.7 38.2 1.0 x Ncbgr
350 8.6 13.8 18.5 22.0 25.5 28.9 32.4 35.9 39.4
400 8.6 13.8 19.7 23.2 26.6 30.1 33.6 37.1 40.5
450 8.6 13.8 20.8 24.3 27.8 31.3 34.7 38.2 41.7
500 8.6 13.8 20.8 25.5 28.9 32.4 35.9 39.4 42.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.2 14.7 18.7 22.7 26.8 30.8 34.8 38.8
150 7.3 10.4 16.1 20.1 24.1 28.1 32.1 36.1 40.1
200 8.2 11.5 17.4 21.4 25.4 29.4 33.5 37.5 41.5
250 8.6 12.7 18.7 22.7 26.8 30.8 34.8 38.8 42.8
1/2 (2) 51 39.0 78.0 203 300 8.6 13.8 20.1 24.1 28.1 32.1 36.1 40.1 44.2 1.0 x Ncbgr
350 8.6 13.8 21.4 25.4 29.4 33.5 37.5 41.5 45.5
400 8.6 13.8 22.7 26.8 30.8 34.8 38.8 42.8 46.8
450 8.6 13.8 24.1 28.1 32.1 36.1 40.1 44.2 48.2
500 8.6 13.8 24.1 29.4 33.5 37.5 41.5 45.5 49.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 27.7 32.5 37.4 42.3 47.2
150 7.3 10.4 16.9 24.4 29.3 34.2 39.0 43.9 48.8
200 8.2 11.5 18.3 26.0 30.9 35.8 40.7 45.5 50.4
250 8.6 12.7 19.7 27.7 32.5 37.4 42.3 47.2 52.1
1/2 (2) 51 39.0 78.0 300 300 8.6 13.8 21.1 29.3 34.2 39.0 43.9 48.8 53.7 1.0 x Ncbgr
350 8.6 13.8 22.5 30.9 35.8 40.7 45.5 50.4 55.3
400 8.6 13.8 24.0 32.5 37.4 42.3 47.2 52.1 56.9
450 8.6 13.8 25.4 34.2 39.0 43.9 48.8 53.7 58.6
500 8.6 13.8 25.4 35.8 40.7 45.5 50.4 55.3 60.2
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 30.9 37.6 43.2 48.8 54.5
150 7.3 10.4 16.9 24.4 32.7 39.4 45.1 50.7 56.4
200 8.2 11.5 18.3 26.0 34.6 41.3 47.0 52.6 58.2
250 8.6 12.7 19.7 27.7 36.4 43.2 48.8 54.5 60.1
1/2 (2) 51 39.0 78.0 400 300 8.6 13.8 21.1 29.3 38.2 45.1 50.7 56.4 62.0 1.0 x Ncbgr
350 8.6 13.8 22.5 30.9 40.0 47.0 52.6 58.2 63.9
400 8.6 13.8 24.0 32.5 41.8 48.8 54.5 60.1 65.7
450 8.6 13.8 25.4 34.2 43.7 50.7 56.4 62.0 67.6
500 8.6 13.8 25.4 35.8 45.5 52.6 58.2 63.9 69.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 30.9 39.8 48.3 54.6 60.9
150 7.3 10.4 16.9 24.4 32.7 41.8 50.4 56.7 63.0
200 8.2 11.5 18.3 26.0 34.6 43.8 52.5 58.8 65.1
250 8.6 12.7 19.7 27.7 36.4 45.8 54.6 60.9 67.2
1/2 (2) 51 39.0 78.0 500 300 8.6 13.8 21.1 29.3 38.2 47.8 56.7 63.0 69.3 1.0 x Ncbgr
350 8.6 13.8 22.5 30.9 40.0 49.8 58.8 65.1 71.4
400 8.6 13.8 24.0 32.5 41.8 51.8 60.9 67.2 73.5
450 8.6 13.8 25.4 34.2 43.7 53.8 63.0 69.3 75.6
500 8.6 13.8 25.4 35.8 45.5 55.8 65.1 71.4 77.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 30.9 39.8 49.5 59.8 66.7
150 7.3 10.4 16.9 24.4 32.7 41.8 51.6 62.1 69.0
200 8.2 11.5 18.3 26.0 34.6 43.8 53.8 64.4 71.3
250 8.6 12.7 19.7 27.7 36.4 45.8 56.0 66.7 73.6
1/2 (2) 51 39.0 78.0 600 300 8.6 13.8 21.1 29.3 38.2 47.8 58.1 69.0 75.9 1.0 x Ncbgr
350 8.6 13.8 22.5 30.9 40.0 49.8 60.3 71.3 78.2
400 8.6 13.8 24.0 32.5 41.8 51.8 62.4 73.6 80.5
450 8.6 13.8 25.4 34.2 43.7 53.8 64.6 75.9 82.8
500 8.6 13.8 25.4 35.8 45.5 55.8 66.7 78.2 85.1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

96 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt RTZ Expansion Anchor 3.0


Table 7 - Factored resistance for 2 or 4 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 9.2 15.5 22.8 30.9 39.8 49.5 59.8 70.8
150 7.3 10.4 16.9 24.4 32.7 41.8 51.6 62.1 73.2
200 8.2 11.5 18.3 26.0 34.6 43.8 53.8 64.4 75.6
250 8.6 12.7 19.7 27.7 36.4 45.8 56.0 66.7 78.1
1/2 (2) 51 39.0 78.0 675 300 8.6 13.8 21.1 29.3 38.2 47.8 58.1 69.0 80.5 1.0 x Ncbgr
350 8.6 13.8 22.5 30.9 40.0 49.8 60.3 71.3 83.0
400 8.6 13.8 24.0 32.5 41.8 51.8 62.4 73.6 85.4
450 8.6 13.8 25.4 34.2 43.7 53.8 64.6 75.9 87.8
500 8.6 13.8 25.4 35.8 45.5 55.8 66.7 78.2 90.3

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 97
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor

Table 8 - Factored resistance for 2 or 4 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 9.2 14.7 18.7 22.7 26.8 30.8 34.8 38.8
150 5.3 10.4 16.1 20.1 24.1 28.1 32.1 36.1 40.1
200 5.5 11.5 17.4 21.4 25.4 29.4 33.5 37.5 41.5
250 5.5 12.7 18.7 22.7 26.8 30.8 34.8 38.8 42.8
1/2 (3-1/4) 83 39.0 78.0 203 300 5.5 13.8 20.1 24.1 28.1 32.1 36.1 40.1 44.2 2.0 x Ncbgr
350 5.5 13.8 21.4 25.4 29.4 33.5 37.5 41.5 45.5
400 5.5 13.8 22.7 26.8 30.8 34.8 38.8 42.8 46.8
450 5.5 13.8 24.1 28.1 32.1 36.1 40.1 44.2 48.2
500 5.5 13.8 24.1 29.4 33.5 37.5 41.5 45.5 49.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 27.7 32.5 37.4 42.3 47.2
150 5.3 10.4 16.9 24.4 29.3 34.2 39.0 43.9 48.8
200 5.5 11.5 18.3 26.0 30.9 35.8 40.7 45.5 50.4
250 5.5 12.7 19.7 27.7 32.5 37.4 42.3 47.2 52.1
1/2 (3-1/4) 83 39.0 78.0 300 300 5.5 13.8 21.1 29.3 34.2 39.0 43.9 48.8 53.7 2.0 x Ncbgr
350 5.5 13.8 22.5 30.9 35.8 40.7 45.5 50.4 55.3
400 5.5 13.8 24.0 32.5 37.4 42.3 47.2 52.1 56.9
450 5.5 13.8 25.4 34.2 39.0 43.9 48.8 53.7 58.6
500 5.5 13.8 25.4 35.8 40.7 45.5 50.4 55.3 60.2
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 30.9 37.6 43.2 48.8 54.5
150 5.3 10.4 16.9 24.4 32.7 39.4 45.1 50.7 56.4
200 5.5 11.5 18.3 26.0 34.6 41.3 47.0 52.6 58.2
250 5.5 12.7 19.7 27.7 36.4 43.2 48.8 54.5 60.1
1/2 (3-1/4) 83 39.0 78.0 400 300 5.5 13.8 21.1 29.3 38.2 45.1 50.7 56.4 62.0 2.0 x Ncbgr
350 5.5 13.8 22.5 30.9 40.0 47.0 52.6 58.2 63.9
400 5.5 13.8 24.0 32.5 41.8 48.8 54.5 60.1 65.7
450 5.5 13.8 25.4 34.2 43.7 50.7 56.4 62.0 67.6
500 5.5 13.8 25.4 35.8 45.5 52.6 58.2 63.9 69.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 30.9 39.8 48.3 54.6 60.9
150 5.3 10.4 16.9 24.4 32.7 41.8 50.4 56.7 63.0
200 5.5 11.5 18.3 26.0 34.6 43.8 52.5 58.8 65.1
250 5.5 12.7 19.7 27.7 36.4 45.8 54.6 60.9 67.2
1/2 (3-1/4) 83 39.0 78.0 500 300 5.5 13.8 21.1 29.3 38.2 47.8 56.7 63.0 69.3 2.0 x Ncbgr
350 5.5 13.8 22.5 30.9 40.0 49.8 58.8 65.1 71.4
400 5.5 13.8 24.0 32.5 41.8 51.8 60.9 67.2 73.5
450 5.5 13.8 25.4 34.2 43.7 53.8 63.0 69.3 75.6
500 5.5 13.8 25.4 35.8 45.5 55.8 65.1 71.4 77.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 30.9 39.8 49.5 59.8 66.7
150 5.3 10.4 16.9 24.4 32.7 41.8 51.6 62.1 69.0
200 5.5 11.5 18.3 26.0 34.6 43.8 53.8 64.4 71.3
250 5.5 12.7 19.7 27.7 36.4 45.8 56.0 66.7 73.6
1/2 (3-1/4) 83 39.0 78.0 600 300 5.5 13.8 21.1 29.3 38.2 47.8 58.1 69.0 75.9 2.0 x Ncbgr
350 5.5 13.8 22.5 30.9 40.0 49.8 60.3 71.3 78.2
400 5.5 13.8 24.0 32.5 41.8 51.8 62.4 73.6 80.5
450 5.5 13.8 25.4 34.2 43.7 53.8 64.6 75.9 82.8
500 5.5 13.8 25.4 35.8 45.5 55.8 66.7 78.2 85.1
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.2 15.5 22.8 30.9 39.8 49.5 59.8 70.8
150 5.3 10.4 16.9 24.4 32.7 41.8 51.6 62.1 73.2
200 8.2 11.5 18.3 26.0 34.6 43.8 53.8 64.4 75.6
250 5.5 12.7 19.7 27.7 36.4 45.8 56.0 66.7 78.1
1/2 (3-1/4) 83 39.0 78.0 675 300 5.5 13.8 21.1 29.3 38.2 47.8 58.1 69.0 80.5 2.0 x Ncbgr
350 5.5 13.8 22.5 30.9 40.0 49.8 60.3 71.3 83.0
400 5.5 13.8 24.0 32.5 41.8 51.8 62.4 73.6 85.4
450 5.5 13.8 25.4 34.2 43.7 53.8 64.6 75.9 87.8
500 5.5 13.8 25.4 35.8 45.5 55.8 66.7 78.2 90.3

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

98 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt RTZ Expansion Anchor 3.0


Table 9 - Factored resistance for 2 or 4 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 9.5 13.0 16.6 20.1 23.7 27.2 30.8 34.3
150 9.4 10.7 14.2 17.8 21.3 24.9 28.4 32.0 35.5
200 10.5 11.8 15.4 18.9 22.5 26.1 29.6 33.2 36.7
250 11.7 13.0 16.6 20.1 23.7 27.2 30.8 34.3 37.9
5/8 (3-1/8) 79 67.2 134.4 127 300 11.7 14.2 17.8 21.3 24.9 28.4 32.0 35.5 39.1 2.0 x Ncbgr
350 11.7 14.2 18.9 22.5 26.1 29.6 33.2 36.7 40.3
400 11.7 14.2 20.1 23.7 27.2 30.8 34.3 37.9 41.5
450 11.7 14.2 21.3 24.9 28.4 32.0 35.5 39.1 42.6
500 11.7 14.2 21.3 26.1 29.6 33.2 36.7 40.3 43.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 10.3 16.5 21.0 25.5 29.9 34.4 38.9 43.4
150 9.4 11.6 18.0 22.5 27.0 31.4 35.9 40.4 44.9
200 10.5 12.9 19.5 24.0 28.4 32.9 37.4 41.9 46.4
250 11.7 14.2 21.0 25.5 29.9 34.4 38.9 43.4 47.9
5/8 (3-1/8) 79 67.2 134.4 203 300 11.7 15.4 22.5 27.0 31.4 35.9 40.4 44.9 49.4 2.0 x Ncbgr
350 11.7 15.4 24.0 28.4 32.9 37.4 41.9 46.4 50.9
400 11.7 15.4 25.5 29.9 34.4 38.9 43.4 47.9 52.4
450 11.7 15.4 27.0 31.4 35.9 40.4 44.9 49.4 53.9
500 11.7 15.4 27.0 32.9 37.4 41.9 46.4 50.9 55.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 10.3 17.3 25.5 30.9 36.4 41.9 47.3 52.8
150 9.4 11.6 18.9 27.3 32.8 38.2 43.7 49.1 54.6
200 10.5 12.9 20.5 29.1 34.6 40.0 45.5 51.0 56.4
250 11.7 14.2 22.1 30.9 36.4 41.9 47.3 52.8 58.2
5/8 (3-1/8) 79 67.2 134.4 300 300 11.7 15.4 23.6 32.8 38.2 43.7 49.1 54.6 60.1 2.0 x Ncbgr
350 11.7 15.4 25.2 34.6 40.0 45.5 51.0 56.4 61.9
400 11.7 15.4 26.8 36.4 41.9 47.3 52.8 58.2 63.7
450 11.7 15.4 28.4 38.2 43.7 49.1 54.6 60.1 65.5
500 11.7 15.4 28.4 40.0 45.5 51.0 56.4 61.9 67.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 10.3 17.3 25.5 34.6 42.0 48.3 54.6 61.0
150 9.4 11.6 18.9 27.3 36.6 44.1 50.4 56.7 63.1
200 10.5 12.9 20.5 29.1 38.7 46.2 52.5 58.9 65.2
250 11.7 14.2 22.1 30.9 40.7 48.3 54.6 61.0 67.3
5/8 (3-1/8) 79 67.2 134.4 400 300 11.7 15.4 23.6 32.8 42.7 50.4 56.7 63.1 69.4 2.0 x Ncbgr
350 11.7 15.4 25.2 34.6 44.8 52.5 58.9 65.2 71.5
400 11.7 15.4 26.8 36.4 46.8 54.6 61.0 67.3 73.6
450 11.7 15.4 28.4 38.2 48.8 56.7 63.1 69.4 75.7
500 11.7 15.4 28.4 40.0 50.9 58.9 65.2 71.5 77.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 10.3 17.3 25.5 34.6 44.6 54.0 61.1 68.1
150 9.4 11.6 18.9 27.3 36.6 46.8 56.4 63.4 70.5
200 10.5 12.9 20.5 29.1 38.7 49.0 58.7 65.8 72.8
250 11.7 14.2 22.1 30.9 40.7 51.3 61.1 68.1 75.2
5/8 (3-1/8) 79 67.2 134.4 500 300 11.7 15.4 23.6 32.8 42.7 53.5 63.4 70.5 77.5 2.0 x Ncbgr
350 11.7 15.4 25.2 34.6 44.8 55.7 65.8 72.8 79.9
400 11.7 15.4 26.8 36.4 46.8 58.0 68.1 75.2 82.2
450 11.7 15.4 28.4 38.2 48.8 60.2 70.5 77.5 84.6
500 11.7 15.4 28.4 40.0 50.9 62.4 72.8 79.9 86.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 10.3 17.3 25.5 34.6 44.6 55.4 66.9 74.7
150 9.4 11.6 18.9 27.3 36.6 46.8 57.8 69.5 77.2
200 10.5 12.9 20.5 29.1 38.7 49.0 60.2 72.1 79.8
250 11.7 14.2 22.1 30.9 40.7 51.3 62.6 74.7 82.4
5/8 (3-1/8) 79 67.2 134.4 600 300 11.7 15.4 23.6 32.8 42.7 53.5 65.0 77.2 84.9 2.0 x Ncbgr
350 11.7 15.4 25.2 34.6 44.8 55.7 67.4 79.8 87.5
400 11.7 15.4 26.8 36.4 46.8 58.0 69.8 82.4 90.1
450 11.7 15.4 28.4 38.2 48.8 60.2 72.2 84.9 92.7
500 11.7 15.4 28.4 40.0 50.9 62.4 74.6 87.5 95.2

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 99
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor


Table 9 - Factored resistance for 2 or 4 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 10.3 17.3 25.5 34.6 44.6 55.4 66.9 79.2
150 9.4 11.6 18.9 27.3 36.6 46.8 57.8 69.5 81.9
200 10.5 12.9 20.5 29.1 38.7 49.0 60.2 72.1 84.6
250 11.7 14.2 22.1 30.9 40.7 51.3 62.6 74.7 87.4
5/8 (3-1/8) 79 67.2 134.4 675 300 11.7 15.4 23.6 32.8 42.7 53.5 65.0 77.2 90.1 2.0 x Ncbgr
350 11.7 15.4 25.2 34.6 44.8 55.7 67.4 79.8 92.8
400 11.7 15.4 26.8 36.4 46.8 58.0 69.8 82.4 95.6
450 11.7 15.4 28.4 38.2 48.8 60.2 72.2 84.9 98.3
500 11.7 15.4 28.4 40.0 50.9 62.4 74.6 87.5 101.0

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

100 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt RTZ Expansion Anchor 3.0


Table 10 - Factored resistance for 2 or 4 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 10.3 14.3 18.1 22.0 25.9 29.8 33.7 37.6
150 6.6 11.6 15.5 19.4 23.3 27.2 31.1 35.0 38.9
200 7.2 12.9 16.8 20.7 24.6 28.5 32.4 36.3 40.2
250 7.2 14.2 18.1 22.0 25.9 29.8 33.7 37.6 41.5
5/8 (4) 102 67.2 134.4 152 300 7.2 15.4 19.4 23.3 27.2 31.1 35.0 38.9 42.8 2.0 x Ncbgr
350 7.2 15.4 20.7 24.6 28.5 32.4 36.3 40.2 44.1
400 7.2 15.4 22.0 25.9 29.8 33.7 37.6 41.5 45.3
450 7.2 15.4 23.3 27.2 31.1 35.0 38.9 42.8 46.6
500 7.2 15.4 23.3 28.5 32.4 36.3 40.2 44.1 47.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 10.3 16.5 21.0 25.5 29.9 34.4 38.9 43.4
150 6.6 11.6 18.0 22.5 27.0 31.4 35.9 40.4 44.9
200 7.2 12.9 19.5 24.0 28.4 32.9 37.4 41.9 46.4
250 7.2 14.2 21.0 25.5 29.9 34.4 38.9 43.4 47.9
5/8 (4) 102 67.2 134.4 203 300 7.2 15.4 22.5 27.0 31.4 35.9 40.4 44.9 49.4 2.0 x Ncbgr
350 7.2 15.4 24.0 28.4 32.9 37.4 41.9 46.4 50.9
400 7.2 15.4 25.5 29.9 34.4 38.9 43.4 47.9 52.4
450 7.2 15.4 27.0 31.4 35.9 40.4 44.9 49.4 53.9
500 7.2 15.4 27.0 32.9 37.4 41.9 46.4 50.9 55.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 10.3 17.3 25.5 30.9 36.4 41.9 47.3 52.8
150 6.6 11.6 18.9 27.3 32.8 38.2 43.7 49.1 54.6
200 7.2 12.9 20.5 29.1 34.6 40.0 45.5 51.0 56.4
250 7.2 14.2 22.1 30.9 36.4 41.9 47.3 52.8 58.2
5/8 (4) 102 67.2 134.4 300 300 7.2 15.4 23.6 32.8 38.2 43.7 49.1 54.6 60.1 2.0 x Ncbgr
350 7.2 15.4 25.2 34.6 40.0 45.5 51.0 56.4 61.9
400 7.2 15.4 26.8 36.4 41.9 47.3 52.8 58.2 63.7
450 7.2 15.4 28.4 38.2 43.7 49.1 54.6 60.1 65.5
500 7.2 15.4 28.4 40.0 45.5 51.0 56.4 61.9 67.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 10.3 17.3 25.5 34.6 42.0 48.3 54.6 61.0
150 6.6 11.6 18.9 27.3 36.6 44.1 50.4 56.7 63.1
200 7.2 12.9 20.5 29.1 38.7 46.2 52.5 58.9 65.2
250 7.2 14.2 22.1 30.9 40.7 48.3 54.6 61.0 67.3
5/8 (4) 102 67.2 134.4 400 300 7.2 15.4 23.6 32.8 42.7 50.4 56.7 63.1 69.4 2.0 x Ncbgr
350 7.2 15.4 25.2 34.6 44.8 52.5 58.9 65.2 71.5
400 7.2 15.4 26.8 36.4 46.8 54.6 61.0 67.3 73.6
450 7.2 15.4 28.4 38.2 48.8 56.7 63.1 69.4 75.7
500 7.2 15.4 28.4 40.0 50.9 58.9 65.2 71.5 77.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 10.3 17.3 25.5 34.6 44.6 54.0 61.1 68.1
150 6.6 11.6 18.9 27.3 36.6 46.8 56.4 63.4 70.5
200 7.2 12.9 20.5 29.1 38.7 49.0 58.7 65.8 72.8
250 7.2 14.2 22.1 30.9 40.7 51.3 61.1 68.1 75.2
5/8 (4) 102 67.2 134.4 500 300 7.2 15.4 23.6 32.8 42.7 53.5 63.4 70.5 77.5 2.0 x Ncbgr
350 7.2 15.4 25.2 34.6 44.8 55.7 65.8 72.8 79.9
400 7.2 15.4 26.8 36.4 46.8 58.0 68.1 75.2 82.2
450 7.2 15.4 28.4 38.2 48.8 60.2 70.5 77.5 84.6
500 7.2 15.4 28.4 40.0 50.9 62.4 72.8 79.9 86.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 10.3 17.3 25.5 34.6 44.6 55.4 66.9 74.7
150 6.6 11.6 18.9 27.3 36.6 46.8 57.8 69.5 77.2
200 7.2 12.9 20.5 29.1 38.7 49.0 60.2 72.1 79.8
250 7.2 14.2 22.1 30.9 40.7 51.3 62.6 74.7 82.4
5/8 (4) 102 67.2 134.4 600 300 7.2 15.4 23.6 32.8 42.7 53.5 65.0 77.2 84.9 2.0 x Ncbgr
350 7.2 15.4 25.2 34.6 44.8 55.7 67.4 79.8 87.5
400 7.2 15.4 26.8 36.4 46.8 58.0 69.8 82.4 90.1
450 7.2 15.4 28.4 38.2 48.8 60.2 72.2 84.9 92.7
500 7.2 15.4 28.4 40.0 50.9 62.4 74.6 87.5 95.2

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 101
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor


Table 10 - Factored resistance for 2 or 4 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 10.3 17.3 25.5 34.6 44.6 55.4 66.9 79.2
150 6.6 11.6 18.9 27.3 36.6 46.8 57.8 69.5 81.9
200 7.2 12.9 20.5 29.1 38.7 49.0 60.2 72.1 84.6
250 7.2 14.2 22.1 30.9 40.7 51.3 62.6 74.7 87.4
5/8 (4) 102 67.2 134.4 675 300 7.2 15.4 23.6 32.8 42.7 53.5 65.0 77.2 90.1 2.0 x Ncbgr
350 7.2 15.4 25.2 34.6 44.8 55.7 67.4 79.8 92.8
400 7.2 15.4 26.8 36.4 46.8 58.0 69.8 82.4 95.6
450 7.2 15.4 28.4 38.2 48.8 60.2 72.2 84.9 98.3
500 7.2 15.4 28.4 40.0 50.9 62.4 74.6 87.5 101.0

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

102 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt RTZ Expansion Anchor 3.0


Table 11 - Factored resistance for 2 or 4 KB-RTZ anchors subject to Shear Loads in Cracked Concrete (f'c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN)1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
150 X X X X 25.6 29.8 34.1 38.3 42.6
200 X X X 22.7 27.0 31.2 35.5 39.8 44.0
250 X X 19.9 24.1 28.4 32.7 36.9 41.2 45.4
300 17.7 X 21.3 25.6 29.8 34.1 38.3 42.6 46.9
3/4 (3-3/4) 95 82.8 165.6 152 2.0 x Ncbgr
350 18.4 X 22.7 27.0 31.2 35.5 39.8 44.0 48.3
400 18.4 X 24.1 28.4 32.7 36.9 41.2 45.4 49.7
450 18.4 X 25.6 29.8 34.1 38.3 42.6 46.9 51.1
500 18.4 X 25.6 31.2 35.5 39.8 44.0 48.3 52.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X X X 29.5 34.5 39.4 44.3 49.2
200 X X X 26.3 31.2 36.1 41.0 46.0 50.9
250 X X 23.0 27.9 32.8 37.7 42.7 47.6 52.5
300 18.3 X 24.6 29.5 34.5 39.4 44.3 49.2 54.2
3/4 (3-3/4) 95 82.8 165.6 203 2.0 x Ncbgr
350 19.0 X 26.3 31.2 36.1 41.0 46.0 50.9 55.8
400 19.0 X 27.9 32.8 37.7 42.7 47.6 52.5 57.4
450 19.0 X 29.5 34.5 39.4 44.3 49.2 54.2 59.1
500 19.0 X 29.5 36.1 41.0 46.0 50.9 55.8 60.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X X X 35.9 41.9 47.9 53.9 59.8
200 X X X 31.9 37.9 43.9 49.9 55.9 61.8
250 X X 24.2 33.9 39.9 45.9 51.9 57.9 63.8
300 18.3 X 25.9 35.9 41.9 47.9 53.9 59.8 65.8
3/4 (3-3/4) 95 82.8 165.6 300 2.0 x Ncbgr
350 19.0 X 27.6 37.9 43.9 49.9 55.9 61.8 67.8
400 19.0 X 29.4 39.9 45.9 51.9 57.9 63.8 69.8
450 19.0 X 31.1 41.9 47.9 53.9 59.8 65.8 71.8
500 19.0 X 31.1 43.9 49.9 55.9 61.8 67.8 73.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X X X 40.1 48.4 55.3 62.2 69.1
200 X X X 31.9 42.4 50.7 57.6 64.5 71.4
250 X X 24.2 33.9 44.6 53.0 59.9 66.8 73.7
300 18.3 X 25.9 35.9 46.8 55.3 62.2 69.1 76.0
3/4 (3-3/4) 95 82.8 165.6 400 2.0 x Ncbgr
350 19.0 X 27.6 37.9 49.1 57.6 64.5 71.4 78.3
400 19.0 X 29.4 39.9 51.3 59.9 66.8 73.7 80.6
450 19.0 X 31.1 41.9 53.5 62.2 69.1 76.0 82.9
500 19.0 X 31.1 43.9 55.8 64.5 71.4 78.3 85.2
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X X X 40.1 51.3 61.8 69.5 77.3
200 X X X 31.9 42.4 53.8 64.4 72.1 79.8
250 X X 24.2 33.9 44.6 56.2 67.0 74.7 82.4
300 18.3 X 25.9 35.9 46.8 58.6 69.5 77.3 85.0
3/4 (3-3/4) 95 82.8 165.6 500 2.0 x Ncbgr
350 19.0 X 27.6 37.9 49.1 61.1 72.1 79.8 87.6
400 19.0 X 29.4 39.9 51.3 63.5 74.7 82.4 90.1
450 19.0 X 31.1 41.9 53.5 66.0 77.3 85.0 92.7
500 19.0 X 31.1 43.9 55.8 68.4 79.8 87.6 95.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X X X 40.1 51.3 63.3 76.2 84.6
200 X X X 31.9 42.4 53.8 66.0 79.0 87.5
250 X X 24.2 33.9 44.6 56.2 68.6 81.8 90.3
300 18.3 X 25.9 35.9 46.8 58.6 71.3 84.6 93.1
3/4 (3-3/4) 95 82.8 165.6 600 2.0 x Ncbgr
350 19.0 X 27.6 37.9 49.1 61.1 73.9 87.5 95.9
400 19.0 X 29.4 39.9 51.3 63.5 76.5 90.3 98.7
450 19.0 X 31.1 41.9 53.5 66.0 79.2 93.1 101.6
500 19.0 X 31.1 43.9 55.8 68.4 81.8 95.9 104.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X X X 40.1 51.3 63.3 76.2 89.8
200 X X X 31.9 42.4 53.8 66.0 79.0 92.8
250 X X 24.2 33.9 44.6 56.2 68.6 81.8 95.8
300 18.3 X 25.9 35.9 46.8 58.6 71.3 84.6 98.8
3/4 (3-3/4) 95 82.8 165.6 675 2.0 x Ncbgr
350 19.0 X 27.6 37.9 49.1 61.1 73.9 87.5 101.7
400 19.0 X 29.4 39.9 51.3 63.5 76.5 90.3 104.7
450 19.0 X 31.1 41.9 53.5 66.0 79.2 93.1 107.7
500 19.0 X 31.1 43.9 55.8 68.4 81.8 95.9 110.7

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 103
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor


Table 12 - Factored resistance for 2 or 4 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 2 Bolts 4 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
150 X X 19.7 24.6 29.5 34.5 39.4 44.3 49.2
200 X X 21.3 26.3 31.2 36.1 41.0 46.0 50.9
250 15.8 X 23.0 27.9 32.8 37.7 42.7 47.6 52.5
300 17.3 X 24.6 29.5 34.5 39.4 44.3 49.2 54.2
3/4 (4-3/4) 121 82.8 165.6 203 2.0 x Ncbgr
350 17.4 X 26.3 31.2 36.1 41.0 46.0 50.9 55.8
400 17.4 X 27.9 32.8 37.7 42.7 47.6 52.5 57.4
450 17.4 X 29.5 34.5 39.4 44.3 49.2 54.2 59.1
500 17.4 X 29.5 36.1 41.0 46.0 50.9 55.8 60.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X 20.7 29.9 35.9 41.9 47.9 53.9 59.8
200 X X 22.5 31.9 37.9 43.9 49.9 55.9 61.8
250 15.8 X 24.2 33.9 39.9 45.9 51.9 57.9 63.8
300 17.3 X 25.9 35.9 41.9 47.9 53.9 59.8 65.8
3/4 (4-3/4) 121 82.8 165.6 300 2.0 x Ncbgr
350 17.4 X 27.6 37.9 43.9 49.9 55.9 61.8 67.8
400 17.4 X 29.4 39.9 45.9 51.9 57.9 63.8 69.8
450 17.4 X 31.1 41.9 47.9 53.9 59.8 65.8 71.8
500 17.4 X 31.1 43.9 49.9 55.9 61.8 67.8 73.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X 20.7 29.9 40.1 48.4 55.3 62.2 69.1
200 X X 22.5 31.9 42.4 50.7 57.6 64.5 71.4
250 15.8 X 24.2 33.9 44.6 53.0 59.9 66.8 73.7
300 17.3 X 25.9 35.9 46.8 55.3 62.2 69.1 76.0
3/4 (4-3/4) 121 82.8 165.6 400 2.0 x Ncbgr
350 17.4 X 27.6 37.9 49.1 57.6 64.5 71.4 78.3
400 17.4 X 29.4 39.9 51.3 59.9 66.8 73.7 80.6
450 17.4 X 31.1 41.9 53.5 62.2 69.1 76.0 82.9
500 17.4 X 31.1 43.9 55.8 64.5 71.4 78.3 85.2
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X 20.7 29.9 40.1 51.3 61.8 69.5 77.3
200 X X 22.5 31.9 42.4 53.8 64.4 72.1 79.8
250 15.8 X 24.2 33.9 44.6 56.2 67.0 74.7 82.4
300 17.3 X 25.9 35.9 46.8 58.6 69.5 77.3 85.0
3/4 (4-3/4) 121 82.8 165.6 500 2.0 x Ncbgr
350 17.4 X 27.6 37.9 49.1 61.1 72.1 79.8 87.6
400 17.4 X 29.4 39.9 51.3 63.5 74.7 82.4 90.1
450 17.4 X 31.1 41.9 53.5 66.0 77.3 85.0 92.7
500 17.4 X 31.1 43.9 55.8 68.4 79.8 87.6 95.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X 20.7 29.9 40.1 51.3 63.3 76.2 84.6
200 X X 22.5 31.9 42.4 53.8 66.0 79.0 87.5
250 15.8 X 24.2 33.9 44.6 56.2 68.6 81.8 90.3
300 17.3 X 25.9 35.9 46.8 58.6 71.3 84.6 93.1
3/4 (4-3/4) 121 82.8 165.6 600 2.0 x Ncbgr
350 17.4 X 27.6 37.9 49.1 61.1 73.9 87.5 95.9
400 17.4 X 29.4 39.9 51.3 63.5 76.5 90.3 98.7
450 17.4 X 31.1 41.9 53.5 66.0 79.2 93.1 101.6
500 17.4 X 31.1 43.9 55.8 68.4 81.8 95.9 104.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X 20.7 29.9 40.1 51.3 63.3 76.2 89.8
200 X X 22.5 31.9 42.4 53.8 66.0 79.0 92.8
250 15.8 X 24.2 33.9 44.6 56.2 68.6 81.8 95.8
300 17.3 X 25.9 35.9 46.8 58.6 71.3 84.6 98.8
3/4 (4-3/4) 121 82.8 165.6 675 2.0 x Ncbgr
350 17.4 X 27.6 37.9 49.1 61.1 73.9 87.5 101.7
400 17.4 X 29.4 39.9 51.3 63.5 76.5 90.3 104.7
450 17.4 X 31.1 41.9 53.5 66.0 79.2 93.1 107.7
500 17.4 X 31.1 43.9 55.8 68.4 81.8 95.9 110.7

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12
30 1.22 s V s V
35 1.32
40 1.41
45 1.50
50 1.58 c1 s
55 1.66 c1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

104 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt RTZ Expansion Anchor 3.0


Table 13 - Factored resistance for 3 or 6 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 9.2 11.9 14.6 17.4 20.1 22.9 25.6 28.4
150 7.8 11.0 13.7 16.5 19.2 22.0 24.7 27.5 30.2
200 9.2 12.8 15.6 18.3 21.1 23.8 26.5 29.3 32.0
250 9.2 14.6 17.4 20.1 22.9 25.6 28.4 31.1 33.9
3/8 (2) 51 41.4 82.8 127 300 9.2 16.5 19.2 22.0 24.7 27.5 30.2 33.0 35.7 1.0 x Ncbgr
350 9.2 16.5 21.1 23.8 26.5 29.3 32.0 34.8 37.5
400 9.2 16.5 22.9 25.6 28.4 31.1 33.9 36.6 39.4
450 9.2 16.5 24.7 27.5 30.2 33.0 35.7 38.4 41.2
500 9.2 16.5 24.7 29.3 32.0 34.8 37.5 40.3 43.0
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.9 15.0 18.5 22.0 25.5 28.9 32.4 35.9
150 7.8 11.9 17.4 20.8 24.3 27.8 31.2 34.7 38.2
200 9.2 13.9 19.7 23.1 26.6 30.1 33.6 37.0 40.5
250 9.2 15.9 22.0 25.5 28.9 32.4 35.9 39.4 42.8
3/8 (2) 51 41.4 82.8 203 300 9.2 17.9 24.3 27.8 31.2 34.7 38.2 41.7 45.1 1.0 x Ncbgr
350 9.2 17.9 26.6 30.1 33.6 37.0 40.5 44.0 47.5
400 9.2 17.9 28.9 32.4 35.9 39.4 42.8 46.3 49.8
450 9.2 17.9 31.2 34.7 38.2 41.7 45.1 48.6 52.1
500 9.2 17.9 31.2 37.0 40.5 44.0 47.5 50.9 54.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.9 15.8 22.5 26.7 31.0 35.2 39.4 43.6
150 7.8 11.9 18.3 25.3 29.5 33.8 38.0 42.2 46.4
200 9.2 13.9 20.7 28.1 32.4 36.6 40.8 45.0 49.2
250 9.2 15.9 23.2 31.0 35.2 39.4 43.6 47.8 52.1
3/8 (2) 51 41.4 82.8 300 300 9.2 17.9 25.6 33.8 38.0 42.2 46.4 50.7 54.9 1.0 x Ncbgr
350 9.2 17.9 28.0 36.6 40.8 45.0 49.2 53.5 57.7
400 9.2 17.9 30.5 39.4 43.6 47.8 52.1 56.3 60.5
450 9.2 17.9 32.9 42.2 46.4 50.7 54.9 59.1 63.3
500 9.2 17.9 32.9 45.0 49.2 53.5 57.7 61.9 66.1
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.9 15.8 22.5 29.9 35.7 40.6 45.5 50.4
150 7.8 11.9 18.3 25.3 33.0 39.0 43.9 48.7 53.6
200 9.2 13.9 20.7 28.1 36.2 42.2 47.1 52.0 56.9
250 9.2 15.9 23.2 31.0 39.3 45.5 50.4 55.2 60.1
3/8 (2) 51 41.4 82.8 400 300 9.2 17.9 25.6 33.8 42.5 48.7 53.6 58.5 63.4 1.0 x Ncbgr
350 9.2 17.9 28.0 36.6 45.6 52.0 56.9 61.7 66.6
400 9.2 17.9 30.5 39.4 48.8 55.2 60.1 65.0 69.9
450 9.2 17.9 32.9 42.2 51.9 58.5 63.4 68.2 73.1
500 9.2 17.9 32.9 45.0 55.1 61.7 66.6 71.5 76.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.9 15.8 22.5 29.9 37.9 45.4 50.9 56.3
150 7.8 11.9 18.3 25.3 33.0 41.4 49.0 54.5 59.9
200 9.2 13.9 20.7 28.1 36.2 44.8 52.7 58.1 63.6
250 9.2 15.9 23.2 31.0 39.3 48.2 56.3 61.8 67.2
3/8 (2) 51 41.4 82.8 500 300 9.2 17.9 25.6 33.8 42.5 51.7 59.9 65.4 70.8 1.0 x Ncbgr
350 9.2 17.9 28.0 36.6 45.6 55.1 63.6 69.0 74.5
400 9.2 17.9 30.5 39.4 48.8 58.6 67.2 72.7 78.1
450 9.2 17.9 32.9 42.2 51.9 62.0 70.8 76.3 81.7
500 9.2 17.9 32.9 45.0 55.1 65.5 74.5 79.9 85.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 9.9 15.8 22.5 29.9 37.9 46.5 55.7 61.7
150 7.8 11.9 18.3 25.3 33.0 41.4 50.3 59.7 65.7
200 9.2 13.9 20.7 28.1 36.2 44.8 54.0 63.7 69.6
250 9.2 15.9 23.2 31.0 39.3 48.2 57.7 67.7 73.6
3/8 (2) 51 41.4 82.8 600 300 9.2 17.9 25.6 33.8 42.5 51.7 61.4 71.6 77.6 1.0 x Ncbgr
350 9.2 17.9 28.0 36.6 45.6 55.1 65.1 75.6 81.6
400 9.2 17.9 30.5 39.4 48.8 58.6 68.9 79.6 85.6
450 9.2 17.9 32.9 42.2 51.9 62.0 72.6 83.6 89.5
500 9.2 17.9 32.9 45.0 55.1 65.5 76.3 87.5 93.5

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 105
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor


Table 13 - Factored resistance for 3 or 6 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 9.9 15.8 22.5 29.9 37.9 46.5 55.7 65.4
150 7.8 11.9 18.3 25.3 33.0 41.4 50.3 59.7 69.6
200 9.2 13.9 20.7 28.1 36.2 44.8 54.0 63.7 73.9
250 9.2 15.9 23.2 31.0 39.3 48.2 57.7 67.7 78.1
3/8 (2) 51 41.4 82.8 675 300 9.2 17.9 25.6 33.8 42.5 51.7 61.4 71.6 82.3 1.0 x Ncbgr
350 9.2 17.9 28.0 36.6 45.6 55.1 65.1 75.6 86.5
400 9.2 17.9 30.5 39.4 48.8 58.6 68.9 79.6 90.8
450 9.2 17.9 32.9 42.2 51.9 62.0 72.6 83.6 95.0
500 9.2 17.9 32.9 45.0 55.1 65.5 76.3 87.5 99.2

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00 s s
25 1.12
30 1.22 V V
35 1.32 s s
40 1.41
45 1.50
50 1.58
c1 c1 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

106 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt RTZ Expansion Anchor 3.0


Table 14 - Factored resistance for 3 or 6 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 11.5 15.1 18.5 22.0 25.5 28.9 32.4 35.9
150 10.2 13.8 17.4 20.8 24.3 27.8 31.3 34.7 38.2
200 12.2 16.1 19.7 23.2 26.6 30.1 33.6 37.1 40.5
250 12.9 18.4 22.0 25.5 28.9 32.4 35.9 39.4 42.8
1/2 (2) 51 58.5 117.0 152 300 12.9 20.7 24.3 27.8 31.3 34.7 38.2 41.7 45.2 1.0 x Ncbgr
350 12.9 20.7 26.6 30.1 33.6 37.1 40.5 44.0 47.5
400 12.9 20.7 28.9 32.4 35.9 39.4 42.8 46.3 49.8
450 12.9 20.7 31.3 34.7 38.2 41.7 45.2 48.6 52.1
500 12.9 20.7 31.3 37.1 40.5 44.0 47.5 50.9 54.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.5 17.4 21.4 25.4 29.4 33.5 37.5 41.5
150 10.2 13.8 20.1 24.1 28.1 32.1 36.1 40.1 44.2
200 12.2 16.1 22.7 26.8 30.8 34.8 38.8 42.8 46.8
250 12.9 18.4 25.4 29.4 33.5 37.5 41.5 45.5 49.5
1/2 (2) 51 58.5 117.0 203 300 12.9 20.7 28.1 32.1 36.1 40.1 44.2 48.2 52.2 1.0 x Ncbgr
350 12.9 20.7 30.8 34.8 38.8 42.8 46.8 50.9 54.9
400 12.9 20.7 33.5 37.5 41.5 45.5 49.5 53.5 57.5
450 12.9 20.7 36.1 40.1 44.2 48.2 52.2 56.2 60.2
500 12.9 20.7 36.1 42.8 46.8 50.9 54.9 58.9 62.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 30.9 35.8 40.7 45.5 50.4
150 10.2 13.8 21.1 29.3 34.2 39.0 43.9 48.8 53.7
200 12.2 16.1 24.0 32.5 37.4 42.3 47.2 52.1 56.9
250 12.9 18.4 26.8 35.8 40.7 45.5 50.4 55.3 60.2
1/2 (2) 51 58.5 117.0 300 300 12.9 20.7 29.6 39.0 43.9 48.8 53.7 58.6 63.4 1.0 x Ncbgr
350 12.9 20.7 32.4 42.3 47.2 52.1 56.9 61.8 66.7
400 12.9 20.7 35.2 45.5 50.4 55.3 60.2 65.1 70.0
450 12.9 20.7 38.0 48.8 53.7 58.6 63.4 68.3 73.2
500 12.9 20.7 38.0 52.1 56.9 61.8 66.7 71.6 76.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 34.6 41.3 47.0 52.6 58.2
150 10.2 13.8 21.1 29.3 38.2 45.1 50.7 56.4 62.0
200 12.2 16.1 24.0 32.5 41.8 48.8 54.5 60.1 65.7
250 12.9 18.4 26.8 35.8 45.5 52.6 58.2 63.9 69.5
1/2 (2) 51 58.5 117.0 400 300 12.9 20.7 29.6 39.0 49.1 56.4 62.0 67.6 73.3 1.0 x Ncbgr
350 12.9 20.7 32.4 42.3 52.7 60.1 65.7 71.4 77.0
400 12.9 20.7 35.2 45.5 56.4 63.9 69.5 75.1 80.8
450 12.9 20.7 38.0 48.8 60.0 67.6 73.3 78.9 84.5
500 12.9 20.7 38.0 52.1 63.7 71.4 77.0 82.7 88.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 34.6 43.8 52.5 58.8 65.1
150 10.2 13.8 21.1 29.3 38.2 47.8 56.7 63.0 69.3
200 12.2 16.1 24.0 32.5 41.8 51.8 60.9 67.2 73.5
250 12.9 18.4 26.8 35.8 45.5 55.8 65.1 71.4 77.7
1/2 (2) 51 58.5 117.0 500 300 12.9 20.7 29.6 39.0 49.1 59.8 69.3 75.6 81.9 1.0 x Ncbgr
350 12.9 20.7 32.4 42.3 52.7 63.8 73.5 79.8 86.1
400 12.9 20.7 35.2 45.5 56.4 67.7 77.7 84.0 90.3
450 12.9 20.7 38.0 48.8 60.0 71.7 81.9 88.2 94.5
500 12.9 20.7 38.0 52.1 63.7 75.7 86.1 92.4 98.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 34.6 43.8 53.8 64.4 71.3
150 10.2 13.8 21.1 29.3 38.2 47.8 58.1 69.0 75.9
200 12.2 16.1 24.0 32.5 41.8 51.8 62.4 73.6 80.5
250 12.9 18.4 26.8 35.8 45.5 55.8 66.7 78.2 85.1
1/2 (2) 51 58.5 117.0 600 300 12.9 20.7 29.6 39.0 49.1 59.8 71.0 82.8 89.7 1.0 x Ncbgr
350 12.9 20.7 32.4 42.3 52.7 63.8 75.3 87.4 94.3
400 12.9 20.7 35.2 45.5 56.4 67.7 79.6 92.0 98.9
450 12.9 20.7 38.0 48.8 60.0 71.7 83.9 96.6 103.5
500 12.9 20.7 38.0 52.1 63.7 75.7 88.2 101.2 108.1

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 107
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor


Table 14 - Factored resistance for 3 or 6 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 11.5 18.3 26.0 34.6 43.8 53.8 64.4 75.6
150 10.2 13.8 21.1 29.3 38.2 47.8 58.1 69.0 80.5
200 12.2 16.1 24.0 32.5 41.8 51.8 62.4 73.6 85.4
250 12.9 18.4 26.8 35.8 45.5 55.8 66.7 78.2 90.3
1/2 (2) 51 58.5 117.0 675 300 12.9 20.7 29.6 39.0 49.1 59.8 71.0 82.8 95.2 1.0 x Ncbgr
350 12.9 20.7 32.4 42.3 52.7 63.8 75.3 87.4 100.0
400 12.9 20.7 35.2 45.5 56.4 67.7 79.6 92.0 104.9
450 12.9 20.7 38.0 48.8 60.0 71.7 83.9 96.6 109.8
500 12.9 20.7 38.0 52.1 63.7 75.7 88.2 101.2 114.7

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00
25 1.12 s s
30 1.22
35 1.32 V V
40 1.41 s s
45 1.50
50 1.58
55 1.66
c1 c1 s

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

108 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt RTZ Expansion Anchor 3.0


Table 15 - Factored resistance for 3 or 6 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 11.5 17.4 21.4 25.4 29.4 33.5 37.5 41.5
150 7.8 13.8 20.1 24.1 28.1 32.1 36.1 40.1 44.2
200 8.2 16.1 22.7 26.8 30.8 34.8 38.8 42.8 46.8
250 8.2 18.4 25.4 29.4 33.5 37.5 41.5 45.5 49.5
1/2 (3-1/4) 83 58.5 117.0 203 300 8.2 20.7 28.1 32.1 36.1 40.1 44.2 48.2 52.2 2.0 x Ncbgr
350 8.2 20.7 30.8 34.8 38.8 42.8 46.8 50.9 54.9
400 8.2 20.7 33.5 37.5 41.5 45.5 49.5 53.5 57.5
450 8.2 20.7 36.1 40.1 44.2 48.2 52.2 56.2 60.2
500 8.2 20.7 36.1 42.8 46.8 50.9 54.9 58.9 62.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 30.9 35.8 40.7 45.5 50.4
150 7.8 13.8 21.1 29.3 34.2 39.0 43.9 48.8 53.7
200 8.2 16.1 24.0 32.5 37.4 42.3 47.2 52.1 56.9
250 8.2 18.4 26.8 35.8 40.7 45.5 50.4 55.3 60.2
1/2 (3-1/4) 83 58.5 117.0 300 300 8.2 20.7 29.6 39.0 43.9 48.8 53.7 58.6 63.4 2.0 x Ncbgr
350 8.2 20.7 32.4 42.3 47.2 52.1 56.9 61.8 66.7
400 8.2 20.7 35.2 45.5 50.4 55.3 60.2 65.1 70.0
450 8.2 20.7 38.0 48.8 53.7 58.6 63.4 68.3 73.2
500 8.2 20.7 38.0 52.1 56.9 61.8 66.7 71.6 76.5
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 34.6 41.3 47.0 52.6 58.2
150 7.8 13.8 21.1 29.3 38.2 45.1 50.7 56.4 62.0
200 8.2 16.1 24.0 32.5 41.8 48.8 54.5 60.1 65.7
250 8.2 18.4 26.8 35.8 45.5 52.6 58.2 63.9 69.5
1/2 (3-1/4) 83 58.5 117.0 400 300 8.2 20.7 29.6 39.0 49.1 56.4 62.0 67.6 73.3 2.0 x Ncbgr
350 8.2 20.7 32.4 42.3 52.7 60.1 65.7 71.4 77.0
400 8.2 20.7 35.2 45.5 56.4 63.9 69.5 75.1 80.8
450 8.2 20.7 38.0 48.8 60.0 67.6 73.3 78.9 84.5
500 8.2 20.7 38.0 52.1 63.7 71.4 77.0 82.7 88.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 34.6 43.8 52.5 58.8 65.1
150 7.8 13.8 21.1 29.3 38.2 47.8 56.7 63.0 69.3
200 8.2 16.1 24.0 32.5 41.8 51.8 60.9 67.2 73.5
250 8.2 18.4 26.8 35.8 45.5 55.8 65.1 71.4 77.7
1/2 (3-1/4) 83 58.5 117.0 500 300 8.2 20.7 29.6 39.0 49.1 59.8 69.3 75.6 81.9 2.0 x Ncbgr
350 8.2 20.7 32.4 42.3 52.7 63.8 73.5 79.8 86.1
400 8.2 20.7 35.2 45.5 56.4 67.7 77.7 84.0 90.3
450 8.2 20.7 38.0 48.8 60.0 71.7 81.9 88.2 94.5
500 8.2 20.7 38.0 52.1 63.7 75.7 86.1 92.4 98.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 11.5 18.3 26.0 34.6 43.8 53.8 64.4 71.3
150 7.8 13.8 21.1 29.3 38.2 47.8 58.1 69.0 75.9
200 8.2 16.1 24.0 32.5 41.8 51.8 62.4 73.6 80.5
250 8.2 18.4 26.8 35.8 45.5 55.8 66.7 78.2 85.1
1/2 (3-1/4) 83 58.5 117.0 600 300 8.2 20.7 29.6 39.0 49.1 59.8 71.0 82.8 89.7 2.0 x Ncbgr
350 8.2 20.7 32.4 42.3 52.7 63.8 75.3 87.4 94.3
400 8.2 20.7 35.2 45.5 56.4 67.7 79.6 92.0 98.9
450 8.2 20.7 38.0 48.8 60.0 71.7 83.9 96.6 103.5
500 8.2 20.7 38.0 52.1 63.7 75.7 88.2 101.2 108.1
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 45
100 X 11.5 18.3 26.0 34.6 43.8 53.8 64.4 75.6
150 7.8 13.8 21.1 29.3 38.2 47.8 58.1 69.0 80.5
200 8.2 16.1 24.0 32.5 41.8 51.8 62.4 73.6 85.4
250 8.2 18.4 26.8 35.8 45.5 55.8 66.7 78.2 90.3
1/2 (3-1/4) 83 58.5 117.0 675 300 8.2 20.7 29.6 39.0 49.1 59.8 71.0 82.8 95.2 2.0 x Ncbgr
350 8.2 20.7 32.4 42.3 52.7 63.8 75.3 87.4 100.0
400 8.2 20.7 35.2 45.5 56.4 67.7 79.6 92.0 104.9
450 8.2 20.7 38.0 48.8 60.0 71.7 83.9 96.6 109.8
500 8.2 20.7 38.0 52.1 63.7 75.7 88.2 101.2 114.7

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00 s s
25 1.12
30 1.22 V V
35 1.32 s s
40 1.41
45 1.50
50 1.58
55 1.66 c1 c1 s

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 109
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor


Table 16 - Factored resistance for 3 or 6 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 11.8 15.4 18.9 22.5 26.1 29.6 33.2 36.7
150 12.9 14.2 17.8 21.3 24.9 28.4 32.0 35.5 39.1
200 15.2 16.6 20.1 23.7 27.2 30.8 34.3 37.9 41.5
250 17.5 18.9 22.5 26.1 29.6 33.2 36.7 40.3 43.8
5/8 (3-1/8) 79 100.8 201.6 127 300 17.5 21.3 24.9 28.4 32.0 35.5 39.1 42.6 46.2 2.0 x Ncbgr
350 17.5 21.3 27.2 30.8 34.3 37.9 41.5 45.0 48.6
400 17.5 21.3 29.6 33.2 36.7 40.3 43.8 47.4 50.9
450 17.5 21.3 32.0 35.5 39.1 42.6 46.2 49.7 53.3
500 17.5 21.3 32.0 37.9 41.5 45.0 48.6 52.1 55.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 12.9 19.5 24.0 28.4 32.9 37.4 41.9 46.4
150 12.9 15.4 22.5 27.0 31.4 35.9 40.4 44.9 49.4
200 15.2 18.0 25.5 29.9 34.4 38.9 43.4 47.9 52.4
250 17.5 20.6 28.4 32.9 37.4 41.9 46.4 50.9 55.4
5/8 (3-1/8) 79 100.8 201.6 203 300 17.5 23.2 31.4 35.9 40.4 44.9 49.4 53.9 58.4 2.0 x Ncbgr
350 17.5 23.2 34.4 38.9 43.4 47.9 52.4 56.9 61.4
400 17.5 23.2 37.4 41.9 46.4 50.9 55.4 59.9 64.4
450 17.5 23.2 40.4 44.9 49.4 53.9 58.4 62.9 67.4
500 17.5 23.2 40.4 47.9 52.4 56.9 61.4 65.9 70.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 34.6 40.0 45.5 51.0 56.4
150 12.9 15.4 23.6 32.8 38.2 43.7 49.1 54.6 60.1
200 15.2 18.0 26.8 36.4 41.9 47.3 52.8 58.2 63.7
250 17.5 20.6 30.0 40.0 45.5 51.0 56.4 61.9 67.3
5/8 (3-1/8) 79 100.8 201.6 300 300 17.5 23.2 33.1 43.7 49.1 54.6 60.1 65.5 71.0 2.0 x Ncbgr
350 17.5 23.2 36.3 47.3 52.8 58.2 63.7 69.2 74.6
400 17.5 23.2 39.4 51.0 56.4 61.9 67.3 72.8 78.3
450 17.5 23.2 42.6 54.6 60.1 65.5 71.0 76.4 81.9
500 17.5 23.2 42.6 58.2 63.7 69.2 74.6 80.1 85.6
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 38.7 46.2 52.5 58.9 65.2
150 12.9 15.4 23.6 32.8 42.7 50.4 56.7 63.1 69.4
200 15.2 18.0 26.8 36.4 46.8 54.6 61.0 67.3 73.6
250 17.5 20.6 30.0 40.0 50.9 58.9 65.2 71.5 77.8
5/8 (3-1/8) 79 100.8 201.6 400 300 17.5 23.2 33.1 43.7 54.9 63.1 69.4 75.7 82.0 2.0 x Ncbgr
350 17.5 23.2 36.3 47.3 59.0 67.3 73.6 79.9 86.2
400 17.5 23.2 39.4 51.0 63.1 71.5 77.8 84.1 90.4
450 17.5 23.2 42.6 54.6 67.2 75.7 82.0 88.3 94.6
500 17.5 23.2 42.6 58.2 71.2 79.9 86.2 92.5 98.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 38.7 49.0 58.7 65.8 72.8
150 12.9 15.4 23.6 32.8 42.7 53.5 63.4 70.5 77.5
200 15.2 18.0 26.8 36.4 46.8 58.0 68.1 75.2 82.2
250 17.5 20.6 30.0 40.0 50.9 62.4 72.8 79.9 86.9
5/8 (3-1/8) 79 100.8 201.6 500 300 17.5 23.2 33.1 43.7 54.9 66.9 77.5 84.6 91.6 2.0 x Ncbgr
350 17.5 23.2 36.3 47.3 59.0 71.3 82.2 89.3 96.3
400 17.5 23.2 39.4 51.0 63.1 75.8 86.9 94.0 101.0
450 17.5 23.2 42.6 54.6 67.2 80.3 91.6 98.7 105.7
500 17.5 23.2 42.6 58.2 71.2 84.7 96.3 103.4 110.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 38.7 49.0 60.2 72.1 79.8
150 12.9 15.4 23.6 32.8 42.7 53.5 65.0 77.2 84.9
200 15.2 18.0 26.8 36.4 46.8 58.0 69.8 82.4 90.1
250 17.5 20.6 30.0 40.0 50.9 62.4 74.6 87.5 95.2
5/8 (3-1/8) 79 100.8 201.6 600 300 17.5 23.2 33.1 43.7 54.9 66.9 79.5 92.7 100.4 2.0 x Ncbgr
350 17.5 23.2 36.3 47.3 59.0 71.3 84.3 97.8 105.5
400 17.5 23.2 39.4 51.0 63.1 75.8 89.1 103.0 110.7
450 17.5 23.2 42.6 54.6 67.2 80.3 93.9 108.1 115.8
500 17.5 23.2 42.6 58.2 71.2 84.7 98.7 113.3 121.0

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

110 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt RTZ Expansion Anchor 3.0


Table 16 - Factored resistance for 3 or 6 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 12.9 20.5 29.1 38.7 49.0 60.2 72.1 84.6
150 12.9 15.4 23.6 32.8 42.7 53.5 65.0 77.2 90.1
200 15.2 18.0 26.8 36.4 46.8 58.0 69.8 82.4 95.6
250 17.5 20.6 30.0 40.0 50.9 62.4 74.6 87.5 101.0
5/8 (3-1/8) 79 100.8 201.6 675 300 17.5 23.2 33.1 43.7 54.9 66.9 79.5 92.7 106.5 2.0 x Ncbgr
350 17.5 23.2 36.3 47.3 59.0 71.3 84.3 97.8 111.9
400 17.5 23.2 39.4 51.0 63.1 75.8 89.1 103.0 117.4
450 17.5 23.2 42.6 54.6 67.2 80.3 93.9 108.1 122.9
500 17.5 23.2 42.6 58.2 71.2 84.7 98.7 113.3 128.3

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00 s s
25 1.12
30 1.22 V V
35 1.32 s s
40 1.41
45 1.50
50 1.58
c1 c1 s
55 1.66

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 111
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor


Table 17 - Factored resistance for 3 or 6 KB-RTZ anchors subject to Shear Loads in Cracked Concrete (f 'c = 20 MPa)

Vsgr - Shear Strength of Concrete 1,2,4,5,6,7 Vcpgr - Pryout


Size hef 3 Spacing, s Vcbgr - Shear Breakout (kN)
Anchor (kN) Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
100 X 12.9 16.8 20.7 24.6 28.5 32.4 36.3 40.2
150 9.6 15.4 19.4 23.3 27.2 31.1 35.0 38.9 42.8
200 10.8 18.0 22.0 25.9 29.8 33.7 37.6 41.5 45.3
250 10.8 20.6 24.6 28.5 32.4 36.3 40.2 44.1 47.9
5/8 (4) 102 100.8 201.6 152 300 10.8 23.2 27.2 31.1 35.0 38.9 42.8 46.6 50.5 2.0 x Ncbgr
350 10.8 23.2 29.8 33.7 37.6 41.5 45.3 49.2 53.1
400 10.8 23.2 32.4 36.3 40.2 44.1 47.9 51.8 55.7
450 10.8 23.2 35.0 38.9 42.8 46.6 50.5 54.4 58.3
500 10.8 23.2 35.0 41.5 45.3 49.2 53.1 57.0 60.9
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 12.9 19.5 24.0 28.4 32.9 37.4 41.9 46.4
150 9.6 15.4 22.5 27.0 31.4 35.9 40.4 44.9 49.4
200 10.8 18.0 25.5 29.9 34.4 38.9 43.4 47.9 52.4
250 10.8 20.6 28.4 32.9 37.4 41.9 46.4 50.9 55.4
5/8 (4) 102 100.8 201.6 203 300 10.8 23.2 31.4 35.9 40.4 44.9 49.4 53.9 58.4 2.0 x Ncbgr
350 10.8 23.2 34.4 38.9 43.4 47.9 52.4 56.9 61.4
400 10.8 23.2 37.4 41.9 46.4 50.9 55.4 59.9 64.4
450 10.8 23.2 40.4 44.9 49.4 53.9 58.4 62.9 67.4
500 10.8 23.2 40.4 47.9 52.4 56.9 61.4 65.9 70.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 34.6 40.0 45.5 51.0 56.4
150 9.6 15.4 23.6 32.8 38.2 43.7 49.1 54.6 60.1
200 10.8 18.0 26.8 36.4 41.9 47.3 52.8 58.2 63.7
250 10.8 20.6 30.0 40.0 45.5 51.0 56.4 61.9 67.3
5/8 (4) 102 100.8 201.6 300 300 10.8 23.2 33.1 43.7 49.1 54.6 60.1 65.5 71.0 2.0 x Ncbgr
350 10.8 23.2 36.3 47.3 52.8 58.2 63.7 69.2 74.6
400 10.8 23.2 39.4 51.0 56.4 61.9 67.3 72.8 78.3
450 10.8 23.2 42.6 54.6 60.1 65.5 71.0 76.4 81.9
500 10.8 23.2 42.6 58.2 63.7 69.2 74.6 80.1 85.6
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 38.7 46.2 52.5 58.9 65.2
150 9.6 15.4 23.6 32.8 42.7 50.4 56.7 63.1 69.4
200 10.8 18.0 26.8 36.4 46.8 54.6 61.0 67.3 73.6
250 10.8 20.6 30.0 40.0 50.9 58.9 65.2 71.5 77.8
5/8 (4) 102 100.8 201.6 400 300 10.8 23.2 33.1 43.7 54.9 63.1 69.4 75.7 82.0 2.0 x Ncbgr
350 10.8 23.2 36.3 47.3 59.0 67.3 73.6 79.9 86.2
400 10.8 23.2 39.4 51.0 63.1 71.5 77.8 84.1 90.4
450 10.8 23.2 42.6 54.6 67.2 75.7 82.0 88.3 94.6
500 10.8 23.2 42.6 58.2 71.2 79.9 86.2 92.5 98.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 38.7 49.0 58.7 65.8 72.8
150 9.6 15.4 23.6 32.8 42.7 53.5 63.4 70.5 77.5
200 10.8 18.0 26.8 36.4 46.8 58.0 68.1 75.2 82.2
250 10.8 20.6 30.0 40.0 50.9 62.4 72.8 79.9 86.9
5/8 (4) 102 100.8 201.6 500 300 10.8 23.2 33.1 43.7 54.9 66.9 77.5 84.6 91.6 2.0 x Ncbgr
350 10.8 23.2 36.3 47.3 59.0 71.3 82.2 89.3 96.3
400 10.8 23.2 39.4 51.0 63.1 75.8 86.9 94.0 101.0
450 10.8 23.2 42.6 54.6 67.2 80.3 91.6 98.7 105.7
500 10.8 23.2 42.6 58.2 71.2 84.7 96.3 103.4 110.4
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 38.7 49.0 60.2 72.1 79.8
150 9.6 15.4 23.6 32.8 42.7 53.5 65.0 77.2 84.9
200 10.8 18.0 26.8 36.4 46.8 58.0 69.8 82.4 90.1
250 10.8 20.6 30.0 40.0 50.9 62.4 74.6 87.5 95.2
5/8 (4) 102 100.8 201.6 600 300 10.8 23.2 33.1 43.7 54.9 66.9 79.5 92.7 100.4 2.0 x Ncbgr
350 10.8 23.2 36.3 47.3 59.0 71.3 84.3 97.8 105.5
400 10.8 23.2 39.4 51.0 63.1 75.8 89.1 103.0 110.7
450 10.8 23.2 42.6 54.6 67.2 80.3 93.9 108.1 115.8
500 10.8 23.2 42.6 58.2 71.2 84.7 98.7 113.3 121.0
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
100 X 12.9 20.5 29.1 38.7 49.0 60.2 72.1 84.6
150 9.6 15.4 23.6 32.8 42.7 53.5 65.0 77.2 90.1
200 10.8 18.0 26.8 36.4 46.8 58.0 69.8 82.4 95.6
250 10.8 20.6 30.0 40.0 50.9 62.4 74.6 87.5 101.0
5/8 (4) 102 100.8 201.6 675 300 10.8 23.2 33.1 43.7 54.9 66.9 79.5 92.7 106.5 2.0 x Ncbgr
350 10.8 23.2 36.3 47.3 59.0 71.3 84.3 97.8 111.9
400 10.8 23.2 39.4 51.0 63.1 75.8 89.1 103.0 117.4
450 10.8 23.2 42.6 54.6 67.2 80.3 93.9 108.1 122.9
500 10.8 23.2 42.6 58.2 71.2 84.7 98.7 113.3 128.3

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
s s
25 1.12
30 1.22
35 1.32 V V
s s
40 1.41
45 1.50
50 1.58
55 1.66
c1 c1 s

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

112 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt RTZ Expansion Anchor 3.0


Table 18 - Factored resistance for 3 or 6 KB-RTZ anchors subject to Shear Loads in Cracked Concrete (f'c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN)1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
150 X X X X 29.8 34.1 38.3 42.6 46.9
200 X X X 28.4 32.7 36.9 41.2 45.4 49.7
250 X X 27.0 31.2 35.5 39.8 44.0 48.3 52.5
300 26.2 X 29.8 34.1 38.3 42.6 46.9 51.1 55.4
3/4 (3-3/4) 95 124.2 248.4 152 2.0 x Ncbgr
350 27.6 X 32.7 36.9 41.2 45.4 49.7 54.0 58.2
400 27.6 X 35.5 39.8 44.0 48.3 52.5 56.8 61.1
450 27.6 X 38.3 42.6 46.9 51.1 55.4 59.6 63.9
500 27.6 X 38.3 45.4 49.7 54.0 58.2 62.5 66.7
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X X X 34.5 39.4 44.3 49.2 54.2
200 X X X 32.8 37.7 42.7 47.6 52.5 57.4
250 X X 31.2 36.1 41.0 46.0 50.9 55.8 60.7
300 27.1 X 34.5 39.4 44.3 49.2 54.2 59.1 64.0
3/4 (3-3/4) 95 124.2 248.4 203 2.0 x Ncbgr
350 28.5 X 37.7 42.7 47.6 52.5 57.4 62.4 67.3
400 28.5 X 41.0 46.0 50.9 55.8 60.7 65.6 70.6
450 28.5 X 44.3 49.2 54.2 59.1 64.0 68.9 73.8
500 28.5 X 44.3 52.5 57.4 62.4 67.3 72.2 77.1
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X X X 41.9 47.9 53.9 59.8 65.8
200 X X X 39.9 45.9 51.9 57.9 63.8 69.8
250 X X 32.8 43.9 49.9 55.9 61.8 67.8 73.8
300 27.1 X 36.3 47.9 53.9 59.8 65.8 71.8 77.8
3/4 (3-3/4) 95 124.2 248.4 300 2.0 x Ncbgr
350 28.5 X 39.7 51.9 57.9 63.8 69.8 75.8 81.8
400 28.5 X 43.2 55.9 61.8 67.8 73.8 79.8 85.8
450 28.5 X 46.6 59.8 65.8 71.8 77.8 83.8 89.8
500 28.5 X 46.6 63.8 69.8 75.8 81.8 87.8 93.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X X X 46.8 55.3 62.2 69.1 76.0
200 X X X 39.9 51.3 59.9 66.8 73.7 80.6
250 X X 32.8 43.9 55.8 64.5 71.4 78.3 85.2
300 27.1 X 36.3 47.9 60.2 69.1 76.0 82.9 89.8
3/4 (3-3/4) 95 124.2 248.4 400 2.0 x Ncbgr
350 28.5 X 39.7 51.9 64.7 73.7 80.6 87.5 94.4
400 28.5 X 43.2 55.9 69.1 78.3 85.2 92.1 99.1
450 28.5 X 46.6 59.8 73.6 82.9 89.8 96.8 103.7
500 28.5 X 46.6 63.8 78.1 87.5 94.4 101.4 108.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X X X 46.8 58.6 69.5 77.3 85.0
200 X X X 39.9 51.3 63.5 74.7 82.4 90.1
250 X X 32.8 43.9 55.8 68.4 79.8 87.6 95.3
300 27.1 X 36.3 47.9 60.2 73.3 85.0 92.7 100.4
3/4 (3-3/4) 95 124.2 248.4 500 2.0 x Ncbgr
350 28.5 X 39.7 51.9 64.7 78.2 90.1 97.9 105.6
400 28.5 X 43.2 55.9 69.1 83.1 95.3 103.0 110.7
450 28.5 X 46.6 59.8 73.6 88.0 100.4 108.2 115.9
500 28.5 X 46.6 63.8 78.1 92.8 105.6 113.3 121.1
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X X X 46.8 58.6 71.3 84.6 93.1
200 X X X 39.9 51.3 63.5 76.5 90.3 98.7
250 X X 32.8 43.9 55.8 68.4 81.8 95.9 104.4
300 27.1 X 36.3 47.9 60.2 73.3 87.1 101.6 110.0
3/4 (3-3/4) 95 124.2 248.4 600 2.0 x Ncbgr
350 28.5 X 39.7 51.9 64.7 78.2 92.4 107.2 115.7
400 28.5 X 43.2 55.9 69.1 83.1 97.6 112.9 121.3
450 28.5 X 46.6 59.8 73.6 88.0 102.9 118.5 127.0
500 28.5 X 46.6 63.8 78.1 92.8 108.2 124.1 132.6
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X X X 46.8 58.6 71.3 84.6 98.8
200 X X X 39.9 51.3 63.5 76.5 90.3 104.7
250 X X 32.8 43.9 55.8 68.4 81.8 95.9 110.7
300 27.1 X 36.3 47.9 60.2 73.3 87.1 101.6 116.7
3/4 (3-3/4) 95 124.2 248.4 675 2.0 x Ncbgr
350 28.5 X 39.7 51.9 64.7 78.2 92.4 107.2 122.7
400 28.5 X 43.2 55.9 69.1 83.1 97.6 112.9 128.7
450 28.5 X 46.6 59.8 73.6 88.0 102.9 118.5 134.7
500 28.5 X 46.6 63.8 78.1 92.8 108.2 124.1 140.6

Influence of Concrete Strength, fb


f'c (MPa) fb
20 1.00
25 1.12 s s
30 1.22
35 1.32 V V
40 1.41 s s
45 1.50
50 1.58
55 1.66
c1 c1 s

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 113
Mechanical Anchoring Systems

3.0 Kwik Bolt RTZ Expansion Anchor


Table 19 - Factored resistance for 3 or 6 KB-RTZ anchors subj ect to Shear Loads in Cracked Concrete (f ' c = 20 MPa)

Vsgr - Shear Strength of Concrete Vcpgr - Pryout


Size hef Spacing, s Vcbgr - Shear Breakout (kN) 1,2,4,5,6,7
Anchor (kN)3 Thickness, h Resistance

c1 - edge distance (mm) kcp X Ncbgr


mm 3 Bolts 6 Bolts mm mm cmin 100 150 200 250 300 350 400 450 kN
150 X X 24.6 29.5 34.5 39.4 44.3 49.2 54.2
200 X X 27.9 32.8 37.7 42.7 47.6 52.5 57.4
250 23.0 X 31.2 36.1 41.0 46.0 50.9 55.8 60.7
300 25.8 X 34.5 39.4 44.3 49.2 54.2 59.1 64.0
3/4 (4-3/4) 121 124.2 248.4 203 2.0 x Ncbgr
350 26.2 X 37.7 42.7 47.6 52.5 57.4 62.4 67.3
400 26.2 X 41.0 46.0 50.9 55.8 60.7 65.6 70.6
450 26.2 X 44.3 49.2 54.2 59.1 64.0 68.9 73.8
500 26.2 X 44.3 52.5 57.4 62.4 67.3 72.2 77.1
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X 25.9 35.9 41.9 47.9 53.9 59.8 65.8
200 X X 29.4 39.9 45.9 51.9 57.9 63.8 69.8
250 23.0 X 32.8 43.9 49.9 55.9 61.8 67.8 73.8
300 25.8 X 36.3 47.9 53.9 59.8 65.8 71.8 77.8 2.0 x Ncbgr
3/4 (4-3/4) 121 124.2 248.4 300
350 26.2 X 39.7 51.9 57.9 63.8 69.8 75.8 81.8
400 26.2 X 43.2 55.9 61.8 67.8 73.8 79.8 85.8
450 26.2 X 46.6 59.8 65.8 71.8 77.8 83.8 89.8
500 26.2 X 46.6 63.8 69.8 75.8 81.8 87.8 93.8
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X 25.9 35.9 46.8 55.3 62.2 69.1 76.0
200 X X 29.4 39.9 51.3 59.9 66.8 73.7 80.6
250 23.0 X 32.8 43.9 55.8 64.5 71.4 78.3 85.2
300 25.8 X 36.3 47.9 60.2 69.1 76.0 82.9 89.8
3/4 (4-3/4) 121 124.2 248.4 400 2.0 x Ncbgr
350 26.2 X 39.7 51.9 64.7 73.7 80.6 87.5 94.4
400 26.2 X 43.2 55.9 69.1 78.3 85.2 92.1 99.1
450 26.2 X 46.6 59.8 73.6 82.9 89.8 96.8 103.7
500 26.2 X 46.6 63.8 78.1 87.5 94.4 101.4 108.3
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X 25.9 35.9 46.8 58.6 69.5 77.3 85.0
200 X X 29.4 39.9 51.3 63.5 74.7 82.4 90.1
250 23.0 X 32.8 43.9 55.8 68.4 79.8 87.6 95.3
300 25.8 X 36.3 47.9 60.2 73.3 85.0 92.7 100.4
3/4 (4-3/4) 121 124.2 248.4 500 2.0 x Ncbgr
350 26.2 X 39.7 51.9 64.7 78.2 90.1 97.9 105.6
400 26.2 X 43.2 55.9 69.1 83.1 95.3 103.0 110.7
450 26.2 X 46.6 59.8 73.6 88.0 100.4 108.2 115.9
500 26.2 X 46.6 63.8 78.1 92.8 105.6 113.3 121.1
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X 25.9 35.9 46.8 58.6 71.3 84.6 93.1
200 X X 29.4 39.9 51.3 63.5 76.5 90.3 98.7
250 23.0 X 32.8 43.9 55.8 68.4 81.8 95.9 104.4
300 25.8 X 36.3 47.9 60.2 73.3 87.1 101.6 110.0
3/4 (4-3/4) 121 124.2 248.4 600 2.0 x Ncbgr
350 26.2 X 39.7 51.9 64.7 78.2 92.4 107.2 115.7
400 26.2 X 43.2 55.9 69.1 83.1 97.6 112.9 121.3
450 26.2 X 46.6 59.8 73.6 88.0 102.9 118.5 127.0
500 26.2 X 46.6 63.8 78.1 92.8 108.2 124.1 132.6
c1 - edge distance (mm)
cmin 100 150 200 250 300 350 400 450
150 X X 25.9 35.9 46.8 58.6 71.3 84.6 98.8
200 X X 29.4 39.9 51.3 63.5 76.5 90.3 104.7
250 23.0 X 32.8 43.9 55.8 68.4 81.8 95.9 110.7
300 25.8 X 36.3 47.9 60.2 73.3 87.1 101.6 116.7
3/4 (4-3/4) 121 124.2 248.4 675 2.0 x Ncbgr
350 26.2 X 39.7 51.9 64.7 78.2 92.4 107.2 122.7
400 26.2 X 43.2 55.9 69.1 83.1 97.6 112.9 128.7
450 26.2 X 46.6 59.8 73.6 88.0 102.9 118.5 134.7
500 26.2 X 46.6 63.8 78.1 92.8 108.2 124.1 140.6

Influence of Concrete Strength, fb

f 'c (MPa) fb
20 1.00 s s
25 1.12
30 1.22 V V
35 1.32 s s
40 1.41
45 1.50
50 1.58
55 1.66 c1 c1 s

IÊœÀÊvœœÌ˜œÌiÃ]ÊÀiviÀÊ̜ʫ>}iÊnn°

114 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Kwik Bolt TZ & RTZ Expansion Anchor 3.0

3.4 Installation Instructions into normal-weight


and lightweight concrete

1. Hammer drill a hole to the same nominal 2. Clean hole.


`ˆ>“iÌiÀÊ>ÃÊ̅iÊ܈ŽÊ œÌÊ/<°ÊÊ/…iʅœiÊ
depth must exceed the anchor embedment
LÞÊ>Ìʏi>ÃÌÊ£É{ʈ˜V…°ÊÊ/…iÊvˆÝÌÕÀiʓ>ÞÊLiÊ
used as a drilling template to ensure proper
anchor location.

Î°Ê ÀˆÛiÊ̅iÊ܈ŽÊ œÌÊ/<ʈ˜ÌœÊ̅iʅœiÊ 4. Tighten the nut to the recommended


using a hammer. The anchor must installation torque.
be driven until at least 4 threads are
below the surface of the fixture.

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 115
Mechanical Anchoring Systems

3.0 Kwik Bolt TZ & RTZ Expansion Anchor

3.5 Ordering Information

Item No. Description Length (in.) Thread Length (in.) Box Quantity
Îä{xn£Ê  ‡/<ÊÎÉnÝÎÊ ÎÊ ÇÉnÊ xä
Îä{xnÓÊ  ‡/<ÊÎÉnÝ·ÎÉ{Ê Î‡ÎÉ{Ê £‡xÉnÊ xä
Îä{xnÎÊ  ‡/<ÊÎÉnÝxÊ xÊ Ó‡ÇÉnÊ xä
Îä{xn{Ê  ‡/<Ê£ÉÓÝ·ÎÉ{Ê Î‡ÎÉ{Ê £‡xÉnÊ Óx
Îä{xnxÊ  ‡/<Ê£ÉÓÝ{‡£ÉÓÊ {‡£ÉÓÊ Ó‡ÎÉnÊ Óx
Îä{xnÈÊ  ‡/<Ê£ÉÓÝx‡£ÉÓÊ x‡£ÉÓÊ Î‡ÎÉnÊ Óx
Îä{xnÇÊ  ‡/<Ê£ÉÓÝÇÊ ÇÊ {‡ÇÉnÊ Óx
Îä{xnnÊ  ‡/<ÊxÉnÝ{‡ÎÉ{Ê {‡ÎÉ{Ê £‡£ÉÓÊ £x
Îä{xn™Ê  ‡/<ÊxÉnÝÈÊ ÈÊ Ó‡ÎÉ{Ê £x
Îä{x™äÊ  ‡/<ÊxÉnÝn‡£ÉÓÊ n‡£ÉÓÊ x‡£É{Ê £x
Îä{x™£Ê  ‡/<ÊxÉnÝ£äÊ £äÊ È‡ÎÉ{Ê £x
ÓäÓnnäÊ  ‡/<ÊÎÉ{Ýx‡£ÉÓÊ xÊ£ÉÓÊ £‡£ÉÓÊ £ä
ÓäÓnn£Ê  ‡/<ÊÎÉ{ÝnÊ nÊ {Ê £ä
ÓäÓnnÓÊ  ‡/<ÊÎÉ{Ý£äÊ £äÊ ÈÊ £ä

ÓäÓnnÎÊ  ‡/<Ê--Îä{ÊÎÉnÝÎÊ ÎÊ ÇÉnÊ xä


ÓäÓnn{Ê  ‡/<Ê--Îä{ÊÎÉnÝ·ÎÉ{Ê Î‡ÎÉ{Ê £‡xÉnÊ xä
ÓäÓnnxÊ  ‡/<Ê--Îä{ÊÎÉnÝxÊ xÊ Ó‡ÇÉnÊ xä
ÓäÓnnÈÊ  ‡/<Ê--Îä{Ê£ÉÓÝ·ÎÉ{Ê Î‡ÎÉ{Ê £‡xÉnÊ Óx
ÓäÓnnÇÊ  ‡/<Ê--Îä{Ê£ÉÓÝ{‡£ÉÓÊ {‡£ÉÓÊ Ó‡ÎÉnÊ Óx
ÓäÓnnnÊ  ‡/<Ê--Îä{Ê£ÉÓÝx‡£ÉÓÊ x‡£ÉÓÊ Î‡ÎÉnÊ Óx
ÓäÓnn™Ê  ‡/<Ê--Îä{Ê£ÉÓÝÇÊ ÇÊ {‡ÇÉnÊ Óx
ÓäÓn™äÊ  ‡/<Ê--Îä{ÊxÉnÝ{‡ÎÉ{Ê {‡ÎÉ{Ê £‡£ÉÓÊ £x
ÓäÓn™£Ê  ‡/<Ê--Îä{ÊxÉnÝÈÊ ÈÊ Ó‡ÎÉ{Ê £x
ÓäÓn™ÓÊ  ‡/<Ê--Îä{ÊxÉnÝn‡£ÉÓÊ n‡£ÉÓÊ x‡£É{Ê £x
ÓäÓn™ÎÊ  ‡/<Ê--Îä{ÊxÉnÝ£äÊ £äÊ È‡ÎÉ{Ê £x
ÓäÓn™{Ê  ‡/<Ê--Îä{ÊÎÉ{Ýx‡£ÉÓÊ x‡£ÉÓÊ £‡Ê£ÉÓÊ £ä
ÓäÓn™xÊ  ‡/<Ê--Îä{ÊÎÉ{ÝnÊ nÊ {Ê £ä
ÓäÓn™ÈÊ  ‡/<Ê--Îä{ÊÎÉ{Ý£äÊ £äÊ ÈÊ £ä

{££ÇÓÇÊ  ‡/<Ê--ΣÈÊÎÉnÝÎÊ ÎÊ ÇÉnÊ xä


{££ÇÎ£Ê  ‡/<Ê--ΣÈÊÎÉnÝ·ÎÉ{Ê Î‡ÎÉ{Ê £‡xÉnÊ xä
{££ÇÎÎÊ  ‡/<Ê--ΣÈÊ£ÉÓÝ·ÎÉ{Ê Î‡ÎÉ{Ê £‡xÉnÊ Óä
{££ÇÎ{Ê  ‡/<Ê--ΣÈÊ£ÉÓÝ{‡£ÉÓÊ {‡£ÉÓÊ Ó‡ÎÉnÊ Óä
{££ÇÎÈÊ  ‡/<Ê--ΣÈÊ£ÉÓÝx‡£ÉÓÊ x‡£ÉÓÊ Î‡ÎÉnÊ Óä
{££ÇÎÇÊ  ‡/<Ê--ΣÈÊxÉnÝ{‡ÎÉ{Ê {‡ÎÉ{Ê £‡£ÉÓÊ £x
{££ÇÎ™Ê  ‡/<Ê--ΣÈÊxÉnÝÈÊ ÈÊ Ó‡ÎÉ{Ê £x
{££Ç{äÊ  ‡/<Ê--ΣÈÊÎÉ{Ýx‡£ÉÓÊ x‡£ÉÓÊ £‡£ÉÓÊ £ä
{££Ç{£Ê  ‡/<Ê--ΣÈÊÎÉ{Ý£äÊ £äÊ ÈÊ £ä

116 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement
Mechanical Anchoring Systems

Notes

Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement 117
Hilti. Outperform. Outlast.
Hilti (Canada) Corporation 1-800-363-4458 www.ca.hilti.coms-EADOWPINE"LVD -ISSISSAUGA /.,.3
Hilti, Inc. (US) 1-800-879-8000 www.us.hilti.com s0/"OX 4ULSA /+s3ERVICIOAL#LIENTEENESPA×OL   
(ILTIISANEQUALOPPORTUNITYEMPLOYERs(ILTIISAREGISTEREDTRADEMARKOF(ILTI #ORP¥#OPYRIGHTBY(ILTI )NCs""
The data contained in this literature was current as of the date of publication. Updates and changes may be made based on later testing. If verification is needed that the data is still current, please contact the Hilti Technical
Support Specialists at 1-800-879-8000. All published load values contained in this literature represent the results of testing by Hilti or test organizations. Local base materials were used. Because of
variations in materials, on-site testing is necessary to determine performance at any specific site. Laser beams represented by red lines in this publication. Printed in the United States *ISO 14001 US Only

118 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com | Hilti (Canada) Corp. 1-800-363-4458 | www.hilti.ca | 2013 Limit States Supplement

Potrebbero piacerti anche