Issue : If the tech sees everything green on the field and the only alarms on site are Resource

Reconfiguration with the RRUs disabled.

Check for the rilinks and see if they are enabled.

If you see all rilinks Enabled and RRUs disabled with no other alarms than the ResourceConfigFailure

Check if the RRU is initialized by checking the output from cabx


The value of 0.5 HZ means it is not initialized

Check for load modules on the RRU

lpr rru

RRU with load modules


This shows that the load modules are missing from the RRU and we need to load them.

Run the following commands for loading the Load Modules on to RRU

Note : Run each of the commands given below one at a time and wait for the “OK” at the completion of
execution of each of the command

cd /c/loadmodules_norepl/
ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/RRU_LoadModule/CXP9013268%12_R
59FM

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/RRU_LoadModule/CXP9013268%12_R
59FM.sm

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/RRU_LoadModule/CXP9013268%9_R6
0HN

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/RRU_LoadModule/CXP9013268%9_R6
0HN.sm

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/RRU_LoadModule/CXP9013268%6_R6
0HN

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/RRU_LoadModule/CXP9013268%6_R6
0HN.sm

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/RRU_LoadModule/CXP9013268%12_R
60HN.sm

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/RRU_LoadModule/CXP9013268%12_R
60HN

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/RRU_LoadModule/CXP9013268%9_R5
9FM

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/RRU_LoadModule/CXP9013268%9_R5
9FM.sm
ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/XMU_LoadModule/CXP9025194%1_R
2AK

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/XMU_LoadModule/CXP9025194%1_R
2AK.sm

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/XMU_LoadModule/CXP9025194%1_R
2AU

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/XMU_LoadModule/CXP9025194%1_R
2AU.sm

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/XMU_LoadModule/CXP9025194%1_R
2BK

ftput
/var/opt/ericsson/nms_umts_bsim_client/files/VTC2E7/Baseline/XMU_LoadModule/CXP9025194%1_R
2BK.sm

Post implementing this commands create a cv and restart the site.

Issue: Security Level fault alarms

Copy the attached file in your home folder in OSS using Filezilla
Run the following commands to overwrite the existing file

Navigate to the directory for security file

cd /c/security

ls
Use the ftput command with the path of the security file

ftput /home/bc076c/QIC/Scripts/security.cfg

Create a cv and restart the site to clear of the alarm.

Issue: VSWR alarm on RF Port

Check if the antenna corresponding to the RRUs in alarm is an AIR antenna.


RRUS0ZB4 represent the internal RRUs of the AIR antenna for the 2100 Band

AIR (Antenna Integrated Radio) antenna as the name explains has the RRUs internal to it for the 2100
band. VSWR/RL is measured on the RF path between the RRU and the antenna. Since the 2100 Band
does not have a separate link between the RRU and the antenna it is not capable of this calculation and
the feature for vswr should be turned off.

Check if this feature is set to true causing the alarm to trigger.

get . vswrsupervisionactive
Set these to false and the alarms should clear