Sei sulla pagina 1di 37

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC TS

11
SECTION 11

CONTROL
AND POWER
SWITCHES

BLUE LINE switchgear

BLUE LINE switchgear


11
BLUE LINE switchgear

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 347


BLUE LINE switchgear
BLUE LINE switchgear

CONTENTS

KRAUS & NAIMER – CONTROL & POWER SWITCHES

Rotary Cam Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350

Panel Mounting Dimensions (mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351

Switch Ordering Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352

OFF/ON Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353

Changeover Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357

RFI Gland Plates - for Secure Screen Continuity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361

RFI Screen Systems for VSD Stainless Steel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362

RFI Screen Systems for VSD Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362

Binary Coded Decimal Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363

Step Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364

Stop/Start Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369

Motor Control Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370

Meter Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371

Optional Extras. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372

Additional Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376

Padlockable Panel Mount, Enclosed Plastic or Stainless Steel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377

Base mounted Padlockable with Extension Shafts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 381

Base mounted Padlockable with Extension Shafts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382

Base mounted Padlockable with Extension Shafts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383

TM

KFD25 T206/AUP0013 KT11V

DC Disconnectors for Solar Photovoltaic (PV) Power Supply System


acc. to IEC 60364-7-712:2002 and AS/NZS 5033:2014

Disconnectors for

2xM25
Photovoltaic
AS/NZS 5033:2014

No. of series contacts


KFD25 Total voltage (DC V)
(1,2 x VOC ARRAY)

Rated current l (A)


3 6
DC-21B

25 510 1000
24 600 1200
19 690 1380
14 900 1500
12 1000 1500
9 1100 1500
7 1200 1500
System voltage 1000V - 1500V is only acceptable
if normally, only non-conductive pollution occurs.
Occasionally, however a temporary conductivity
caused by condensation may be expected.
132
132

M20

85 64 17

Suggested
Input Input Tightening torque
wiring diagram Strip length
for terminal screws
- Non Polarised

Input

5 7
KFD25 1,25 Nm KFD25 9
2 12
This enclosure is made from
self-extinguishing material
Output
Output Output and conforms to UL94-V0

Contact development: 2 pole, 6 contacts per circuit (2 x 3 in series)

BLUE LINE switchgear


General Data
Switch Disconnector according to EN 60947-3 respectively VDE 0660 Part 107
Utilization Category: for Photovoltaic Application
DC-21B (Switching of resistive loads, including moderate overloads)
with rapid handle operation
Overvoltage category III, pollution degree II
Terminal Lugs finger-proof according to VDE 0660-514 and BGV A3, IP 20

11
Maximum permissible wire size (use copper wire only)
single core wire or stranded wire KFD25: 6 mm2
flexible wire KFD25: 4 mm2, or 6 mm2 flexible wire with a diameter not larger than 3,9mm after the insulation has
been removed and the end has been reshaped.
Mounting
Plastic Enclosures, Protection IP66/67, totally insulated, threaded entries
OFF-position lockable with padlocks, cover coupling with interlock
BLUE LINE switchgear

Rated Value / Order Number


Operational Current (enclosed up to 50 ˚C)
7A 9A 12 A 14 A 19 A 24 A 25 A
DC-21B
1,2 x Voc 2 pol 1500 V 1500 V 1500 V 1500 V 1380 V 1200 V 1000 V
1,2 x Voc on each side 1200 V 1100 V 1000 V 900 V 690 V 600 V 510 V
Insulation Voltage 1500 V 1500 V 1500 V 1500 V 1500 V 1500 V 1500 V

Order Number <------------------------------- KFD25 T206/AUP0013 KT11V ------------------------------->

Data valid only, if the pre-assembled jumpers have not been modified.

www.krausnaimer.com Signed: Taylor 11/17

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 349


BLUE LINE switchgear
BLUE LINE switchgear

Specifications

Rotary Cam Switches

According to IEC 60947-3/VDE 0660 part 107


Nominal Thermal Motor Rating
Rotary Cam Switches
Escutcheon Plate Dimensions TYPE Rated Values
Cable Voltage Current 3 x 380 V – 440 V
TYPE mm2According toUiIEC
According to IEC 60947-3/VDEIU0660,
60947-3/VDE Ith
0660,part 107
part AC-23A
107 AC-3
Escutcheon
Rotary CamPlate Dimensions
Switches Rated Values
Note: for drilling details
Cable Nominal V
Thermal
A
Motor Rating
KW KW
Rotary mm 2 Voltage Current 3 x 380 V - 440 V
refer to Cam
pages Switches
31 & 32 According to
According to IEC Rated
60947-3/VDE 0660, Values
0660,part 107
Escutcheon Plate Dimensions
TYPE Ui IuIEC
/Ith 60947-3/VDE
AC-23A part
AC-3107
Cable Nominal
According toThermal
IEC Motor0660,
60947-3/VDE Rating
part 107
Note: for drilling details TYPE According
V toA IEC 60947-3/VDE
kW 0660, part
kW 107
Escutcheon Plate Dimensions mm2 Voltage Current 3 x 380 V - 440 V
refer to pages 31 & 32 Cable Nominal Thermal Motor Rating
S00for drilling details
S00
Note: CA4 CA4 2
mmx 1.5
2 2x1.5
Ui
440
Voltage
Iu/Ith 440
10
Current
AC-23A 10 2.2
3 AC-3
3 x 380 V - 440 V 3 2.2
Rotary
refer Cam 31
to pages Switches
& 32 Rated Values2.2
CG4 CG4 2 x 1.5 2x1.5
440
Ui
V I /I 440
10
A
u th
AC-23A 10 AC-3
3
kW kW 3 2.2
According to IEC 60947-3/VDE 0660, part 107
S00
Escutcheon Plate Dimensions
TYPE
CA4 2 x 1.5According
440
V to IEC A 60947-3/VDE
10 kW0660, part 107
3 2.2
kW

CG4 2 x 1.5Nominal
Cable 440 Thermal
10 Motor
3 Rating 2.2
S00
Note: for drilling details
S0
CA4
CG mm2 x
2 1.5 Voltage
440 10
Current 3
3 x 380 V - 440 V 2.2
refer to pages 31 & 32 CG48 2
2x x 2.5
1.5U 690440 20
Iu/Ith10
7.5
3
AC-23A
5.5
AC-32.2
CA10 2 x 2.5 i 690 20 7.5 5.5
CA20CG 8 2 X 4 V 2x2.5 690 A 25
690 kW 11 20
kW 7.5 7.5 5.5
S0
S00
CG 8
CA25 2 x 2.5
6
CA4 CA102 x 1.5 440
CA10 2 x 2.5
690
2x2.5 10
20
32 690
3
7.5
15 20
2.2
5.5
11 7.5 5.5
CH10 4 440 690 20 7.5 5.5
S0
S0
CG
CG4 8CA202 2x 1.5
CA20
CH16
CA10
2X
2x
x 2.5
x4
4
2.5 690
2x4
690
690
10
25 690
20 3 7.5
11 25 7.5
2.2 5.5 11 7.5
20 7.5 5.5
Rotary Cam Switches CA25CA25 2 x 6
CA20 2X4
2x6
690
690 Rated 32Values
25
690 15
11
32 117.5
15 11
TYPE
CH10CH10 2 x 4
CA25 According
2 x 6to
According to IEC 2x4
690
IEC 690
60947-3/VDE
60947-3/VDE0660,
20
32part
0660,
690
107
part 107
7.5
15 20 5.5
11 7.5 5.5
CH16 2 x 4 690 25 11 7.5
S0 Escutcheon Plate Dimensions
Note: for drilling details
CG 8 CH16
CH10
Cable
CA10
22 x 2.5
Nominal
22 x 2.5
690
x 4 Thermal2x4 Motor
690 20 690 7.5 7.5
20Rating 25
5.5 5.5 11 7.5
refer to pages 31 & 32
mm
CH16
2 Voltage
x 4 690
Current
690
3 x 20 25
380 V - 440 V 7.5 11 5.5 7.5
CA20 U i2 X 4
I /I
u 690
AC-23A AC-3
th 25 11 7.5
S1 CA25
CA10BCA10B
V
22x6
x 2.5
A
6902x2.5
690 kW
32 20 kW
690 15 7.5 20
11 5.5 7.5 5.5
S00 CA4 CH10
CA20BCA20B
2 x 1.5 44022x4
x 4 10690 690
2x4 3 20 25
690
2.2 7.5 11 5.5 7.5
25 11 7.5
CG4 2 x 1.5 440
CH16
CA25B 22 x 6 10690
x4 690 3 25 32 2.2 11 15 7.5 11
S1 CA40CA25B 2
CA10B 1 x 2.5
16 6902x6 20
40 690 7.5
18.5 32 155.5 15 11
CA20B
CA50 CA40 2
1 x416 1x16
690 25
50 690 11
22 40 18.5
7.5 18.5 15
S1 S0 CG 8 CA10B
2 x 2.5 690 2 x 2.5
CA25B
CA10 CA63 CA50 2x6
690 1
20 690
1x16
690 7.5 20
32 5.5
690
7.5
15
5.5
50 18.5
11 22 18.5
2 x 2.5
CA20B 2 x 16
4 20 690 7.5 63
25 5.5 30
11 7.5
CA20 CA40 690 1 x 1625 690 40 18.5 15
S1 C26 2 6 18.5
2X4 32
11690
CA63 1x16
11 7.5 15 63 18.5
11
CA25 CA25B
2
CA50x 6 690 2 x 6 32 690
1 15 32 15 11 30
C32 2x 16 690
x 10
50 22 15
S1 CA40
CH10 CA10B
CH16 C42
2x4
CA63
2x4
C26 21
690
1
690 2
x 2.5
x 16 2x6
1620690
690
690
7.520 40
63 690
5.5 7.5 18.5
30 32 15
5.5 18.5 15 11
CA50
CA20B 21 x4x 1625690
690 11
25 50
7.5
11 22 7.5 18.5
C26
CHR10B C32 2 x6
Ring 2x10
690 32 690 15 50 11 22 15
CA63
CA25B 21 x6x 16 690690 32 20
63 15 7.5
30 11 5.5
18.5
S2 C26 C42 1 Ring
C32
CHR20B
CA40
C42
2 x 10 690
2x 16
2
x 6 690
x 16
2x16
690
690
50
40 25
32
63
690 22
11
18.515
30
63 15
15 7.5
11
18.5
30 18.5
C32CHR10B
CA50
CHR10B
12 x 16
x 10 690Ring
690 50 50 690 22 22 20
18.5 15 7.5 5.5
S1 C43
CA10BCA63 1 Ring
2 x
x 16
2x 16
690
1620690
20
7.563 63 30 7.5
30 5.5
18.5
18.5 18.5
S2 C42 CHR20B
2 x 2.5 690
CHR20B
C80 Ring Ring
690
690
63
11 32 25
690
5.5 30
11 25 7.5 11 7.5
CA20BC262 x 4 2 35
690 x6 25690 115 7.5 15 45 30
11 5.5
CA25B CHR10B
2x6 690 Ring 32 690 15 20 11 7.5
C125
C32 2 70
x 10 690 50 150 22 75 15 37
S2 CA40 CHR20B
1 x 16 690 Ring 40 690
C43
C200-4
CA50 C421 x 16 69022 M8
x 16
690
x 1650690
690
18.5 25
22 63 63
200
15
18.5
11
30 30
75
7.5
18.5 18.5
37
C80
CA63 CHR10B
1 x 16 690 35 63690
Ring 690 30 20 115 18.5 7.5 45 5.5 30
C26 C43
2x6 690 2 x 16 32 690 15 63 11 30 18.5
S2 C125
C32 CHR20B
2 x 10 690
C80
70 50690
Ring
35
690
690
150
22 25 115 15 11 75
45
7.5 37
30
C42 2 x 16C43690 M8 63 2x16
C200-4 690 30 200 690
18.5 75 63 37 30 18.5
CHR10BC125 70 690 7.563 150 75 37
C43Ring 690 2 x 16 20690 5.5 30 18.5
S2 Ring C80690 M8 25 690
CHR20BC200-4 35 11
115200
690
7.5
45 75
115
30 37
45 30
S2 C80 35 690
C43 C125
2 x 16 C125690
70 63690 70 30 150 690
18.5 75 150
37 75 37
C80 C200-4
C125
35
70
C200-4
690
M8
690
115
690
150
M8 45 200
75
30
37
690 75 200
37 75 37
S3 C200-4 M8 690 200 75 37

C315 M12 690 315 132 55


S3 C316 M12 1000 315 132 55
S3 L400
L600 C315 M12
C315
M12
M16
690
M12
690
500
800 690
315
132
132 315 55
55
132 55
S3
S3 C316
C315C316 M16
L800 M12 1000
M12 M12
690
690
315
315 1000
1100 132
132 315 5555 132 55
C315 L400
L1200
M12 690 M12
M16 315 690 132 500 145055 132 55
C316 C316M12
L600
L1600
C315
L400
1000
M12
M12 3151000
2
M16 X M16 690
M12
690 132
315
315
800
1900 55 690 132
132
132 500
55
55
55 132 55
L400 L400 690 M12 500 690 132 500 55 132 55
M16 L600
M12
L800
L2000
L600 C316 M122M16
M16 X M16 M16 1323151100
690 2400 55690 132 132 800
55 55 132 55
S3 L600 690 1000
800
690 800 132 55
L1200
L800 L400M16
L1200 L800
M16
L800690 M16 1450
690
M12 M16 1100
690 M16 132500110055690 132132 1100
690
690
132 1450 55 132 55 55
55 132 55
L1600
L600 M16 2
For X M16
further
690 technical details,
690 132800190055 refer to Catalogue
132 100 and
55 55 120.
L1600 L1200 L1200
2 X M16 690 M16 1900 690
Gold M16
contacts 1450 690 132
see 132 1450
10055 132 55
L2000
L2000 L800
2 X M16 690 M16 2 X M16 690
2400 690 and132quick
1100 connects
2400 55 132 Catalogue
132 55 P4.
55
L1600
L1200 L1600M16 2 X M16690 2xM16
690 14501900 690 132132 1900
55 55 132 55
L2000 2andM16
X quick
M16
For further technical details, refer to Catalogue
690 100 and 120.
2400 132 100 55and55
. L1600 L2000
Gold contacts2 XFor 2xM16
further
690 technical
connects 1900 690
details,
see Catalogue 100 refer
P4. to132
Catalogue 2400 120. 132 55
L2000 2 XGold
M16
For
contacts and quick
690technical
further 2400 connects see Catalogue55
details, refer to132
100 P4.
Catalogue 100 and 120.
. For Safety and Maintenance Switches Refer Page 16-19
. For
For Safety and Maintenance Switches Refer
Gold
Page
contacts and quick connects see Catalogue 100 P4.
further
16-19 technical details, refer to Catalogue 100 and 120.
Gold contacts and quick connects see Catalogue 100 P4. 5
. For Safety and Maintenance Switches Refer Page 16-19 5
.
For Safety and Maintenance Switches Refer Page 16-19
For Safety and Maintenance Switches Refer Page 16-19 5
TM

5
5
Rotary Cam Cam
Rotary Switches - Panel
Switches Mounting
- Panel Mounting

Rotary Cam Switches

E
E E PaM
Panel

Rotary Cam Switches


E Size 0Size
- Size
0

D2

D2

D1

D1
Panel Mounting Dimensions (mm)
CA63
E Panel Mounting Size 0 – Size 3 CA50
CA63
CA50
CAD‘s CAD‘s CA40 CA40
CG4 CG4 CA20 CA20
CA10 CA10 CA25 CA25
C26 C32
C26 C
A A30 3048 48 48 48 48 48 64 6464 6

CA63 B B28 2843 43 45 45 46 46 45/58 60


45/58 60

CAD’s CA20 CA10B CA50 C200-4


C C4 4 4 4 4 4 4 4 4 4 4
CG4 C32 C42 C80 C315 L400
4

CA10 CA25 CA20B CA40 C125


D1 D1 3,2 3,25 5 5 5 5 5 5 5 5 5

C26 D2 8
D2 8 8 8 8 8 10 10 10 10
10 10

E
A 30 48 48 64 64 64 64 88 88 E - 36
130
- 36 36 36 36 36 48 48
48 48

M M- - 4,5 4,5 4,5 4,5 5,5 5,56,5 7.5


6,5 7.5
B 28 43 45/46 56 56/64 60 66 84 88 126
C 4 4 4 4 4 4 4 5.5 5.5 7
D1 3.2 5 5 5 5 5 5 6 6 7
Length L
Length L
D2 8-11 8-15 8-15 10-15 10-15 10-15 10-15 13-17 13-17 CA63
16-20
CA63
E - 36 36 48 48 48 48 68 StagesStages 68
CAD‘s CAD‘s
CA50
CA40 104 CA50
CA40
CG4 CG4 CA20 CA20
CA10 CA10 CA25 CA25
C26 C32 C42
M - 4.5 4.5/5.5 5 7.6 7.5 7.5 9.4 9.4 11.9 C26 C32
38,5 31,7 31,735,9 35,937,2
1 38,5 37,241 4145,8 45,849,8
1
50 50 41,2 41,248,6 48,651,2
2 51,253.7 63,3
53.7 63,371,3
2
62,5 50,7 50,761,3 61,365,2
3 65,266.4 80,8 80,892,8

Length L
62,5 66.4
3
74,5 60,2 60,274 74 79,2
4 74,5 79,279.1 98,3
79.1 98,3114,3
4
86,5 69,7 69,786,7 86,793,2 91.8 115,8 135,8
5 5
86,5 93,2 91.8 115,8

CA63 6
94,5
6
79,2
94,5 79,299,4 99,4107,2 104.5
107,2 133,3
104.5 157,3
133,3

CAD’s CA20 CA10B CA50 C200-4


110,5 C31588,7L-switches
88,7 112,1 121,2 117.2 150,8 178,8
Stages CG4 C32 C42 C80 7 110,5 112,1 121,2 117.2 150,8
7
CA10 CA25 CA20B CA40 C125
8
122,5
8
Size98,2
98,2
122,5 S3124,8 124,8135,2 129.9
135,2 168,3
129.9 200,3
168,3

C26 9
-
9
- 107,7 137,5
107,7 149,2
137,5 142.6
149,2 185,8
142.6 221,8
185,8

1 38.5 33.5 37.7/39 38.9/43.1 41 45.8 49.8 61.5 67.5 78.6


- 117,2 150,2 163,2 155.3 203,3 243,3
10 10
- 117,2 150,2 163,2 155.3 203,3

- 126,7 162,9 177,2 168


11 - 126,7 162,9 177,2 168220,8 264,8
220,8
11
2 50.5 43 50.4/53 48.4/55.8 53.7 63.3 71.3 88 100
- 136,2
117.2 175,6191,2
175,6 238,3 286,3
12 12
- 136,2 191,2 238,3

3 62.5 52.5 63.1/67 57.9/68.5 66.4 80.8 92.8 114.5 132.5 155.8
4 74.5 62 75.8/81 67.4/81.2 79.1 98.3 114.3 141 165 194.4
5 86.5 71.5 88.5/95 76.9/93.9 91.8 115.8 135.8 167.5 197.5 233

BLUE LINE switchgear


6 98.5 81 101.2/109 86.4/106.6 104.5 133.3 28 28
157.3 194 230 271.6
7 110.5 90.5 113.9/123 95.9/119.3 117.2 150.8 178.8 220.5 262.5 310.2
8 122.5 100 126.6/137 105.4/132 131.4 168.3 200.3 247 295 348.8
9 - 109.5 139.3/151 114.9/144.7 144.1 185.8 221.8 273.5 327.5 387.4
10 - 119 152/165 124.4/157.4 156.8 203.3 243.3 300 360 426

11
11 - 128.5 164.7/179 133.9/170.1 169.5 220.8 264.8 326.5 392.5 464.6
12 - 138 177.4/193 143.4/182.8 182.2 238.3 286.3 353 425 503.2
BLUE LINE switchgear

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 351


BLUE LINE switchgear
BLUE LINE switchgear

Specifications

Switch Ordering Chart

Mounting Requirements

 E Panel Mount. (5 hole mount)  L100 Various shaft lengths. (metal)

 VE Base mount suitable for door clutch etc.


 M004 Adjustable shaft. (advise length)

 E-V Panel Mount. ( vertical access to terminals)


 PF Enclosure ABS IP56.

 E22 Panel mount. (3 hole, size 0)


 GK Enclosure aluminium IP54.

 ER Combined panel square base plates.


 M280E Door clutch (specify depth required).

 T146 K DIN rail mounting plate. (size 0 and size 1)


 6 CL Enclosure 56 series.

FT1 Single hole mtg. w/o esc. plate IP65.


 (S0 = 22.3mm)  6 SS Enclosure stainless steel.

FT2 Single hole mtg. with square plates IP65.


 (S0 = 22.3mm)  KS/KL Enclosures IP65.

EF1 Panel seal IP65. (mounts between switch and


 panel).  6S115 x 70 Wall plate stainless or plastic.

 KD/KN Heavy duty mounting plate and metal shaft.


 Other, nominate type of mounting required.

Handle Operation

 Normal/standard handle (G251) or ...................  V840A/. Padlockable handle. (S0 & S1)

 V750D Key operator size 00-0.  V845 Padlock Handle. (c/w esc. plate)

 V755A or C Key operator. (530 series)  V840G Padlock device.

 V750/A9 Key operator size 0 switch. (Lockwood)  V850 Padlockable with handle device.

 6SOLW V750 Key operator. (201 Lockwood etc.)  V400 Push-button interlock device.

 V760 Seperate key and handle.  Other specify

Essential Data

1. Switch/circuit requirement... Amp........................ Volts........................ kW........................

2. Cable Size............................................. or limiting dimensions.............................................

3. AC or DC (DC voltage required).......................................Duty:-AC21/AC22/AC23/AC11 or other.

4. PLC/Electronic circuit/dry circuit or standard switch.

TM
Rotary Cam Switches

Rotary Cam Switches

OFF/ON Switches

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal Current IU = Ith A 10 20 25 32 40 50
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal Current IU = Ith A 63 115 150 200 315 500
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


1 Pole
OFF / ON Switches CA10 A200-620 E 1
60° Switching
CH10 A200-620 E 1
CA20 A200-620 E 1
CA25 A200-620 E 1
CA40/C26 A200-620 E 1
CA50/C32 A200-620 E 1
CA63/C42 A200-620 E 1

BLUE LINE switchgear


C80 A200-620 E 1
C125 A200-620 E 1
C200-4 A200-620 E 1
C315 A200-620 E 1
2 Pole
CA10 A201-620 E
CH10 A201-620 E
1
1 11
CA20 A201-620 E 1
BLUE LINE switchgear

CA25 A201-620 E 1
CA40/C26 A201-620 E 1
CA50/C32 A201-620 E 1
CA63/C42 A201-620 E 1
C80 A201-620 E 1
C125 A201-620 E 1
C200-4 A201-620 E 1
C315 A201-620 E 1

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 353


BLUE LINE switchgear
BLUE LINE switchgear

OFF/ON Switches – continued

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal Current IU = Ith A 10 20 25 32 40 50
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
CA63 C80 C125 C200-4 C315 L400
Rated Thermal Current IU = Ith A 63 115 150 200 315 500
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


3 Pole
OFF / ON Switches CA10 A202-620 E 2
60° Switching
CH10 A202-620 E 2
CA20 A202-620 E 2
CA25 A202-620 E 2
CA40/C26 A202-620 E 2
CA50/C32 A202-620 E 2
CA63/C42 A202-620 E 2
C80 A202-620 E 2
C125 A202-620 E 2
C200-4 A202-620 E 2
C315 A202-620 E 2
4 Pole
CA10 A203-620 E 2
CH10 A203-620 E 2
CA20 A203-620 E 2
CA25 A203-620 E 2
CA40/C26 A203-620 E 2
CA50/C32 A203-620 E 2
CA63/C42 A203-620 E 2
C80 A203-620 E 2
C125 A203-620 E 2
C200-4 A203-620 E 2
C315 A203-620 E 2

TM
Rotary Cam Switches

OFF/ON Switches – continued

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal
IU = Ith A 10 20 25 32 40 50
Current
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal
IU = Ith A 63 115 150 200 315 500
Current
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


1 Pole
OFF / ON Switches CA10 A290-620 E 1
90° Switching CH10 A290-620 E 1
CA20 A290-620 E 1
CA25 A290-620 E 1
CA40/C26 A290-620 E 1
CA50/C32 A290-620 E 1
CA63/C42 A290-620 E 1
C80 A290-620 E 1
C125 A290-620 E 1
C200-4 A290-620 E 1
C315 A290-620 E 1
2 Pole
CA10 A291-620 E 1
CH10 A291-620 E 1
CA20 A291-620 E 1
CA25 A291-620 E 1

BLUE LINE switchgear


CA40/C26 A291-620 E 1
CA50/C32 A291-620 E 1
CA63/C42 A291-620 E 1
C80 A291-620 E 1
C125 A291-620 E 1
C200-4 A291-620 E 1

11
C315 A291-620 E 1
3 Pole
CA10 A292-620 E 2
CH10 A292-620 E 2
BLUE LINE switchgear

CA20 A292-620 E 2
CA25 A292-620 E 2
CA40/C26 A292-620 E 2
CA50/C32 A292-620 E 2
CA63/C42 A292-620 E 2
C80 A292-620 E 2
C125 A292-620 E 2
C200-4 A292-620 E 2
C315 A292-620 E 2

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 355


BLUE LINE switchgear
BLUE LINE switchgear

OFF/ON Switches – continued

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal
IU = Ith A 10 20 25 32 40 50
Current
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal
IU = Ith A 63 115 150 200 315 500
Current
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


OFF / ON Switches 4 Pole
90° Switching CA10 A324-620 E 2
CH10 A324-620 E 2
CA20 A324-620 E 2
CA25 A324-620 E 2
CA40/C26 A324-620 E 2
CA50/C32 A324-620 E 2
CA63/C42 A324-620 E 2
C80 A324-620 E 2
C125 A324-620 E 2
C200-4 A324-620 E 2
C315 A324-620 E 2
6 Pole
CA10 A326-620 E 3
CH10 A326-620 E 3
CA20 A326-620 E 3
CA25 A326-620 E 3
CA40/C26 A326-620 E 3
CA50/C32 A326-620 E 3
CA63/C42 A326-620 E 3
C80 A326-620 E 3
C125 A326-620 E 3
C200-4 A326-620 E 3
C315 A326-620 E 3
8 Pole - 60°
CA10 A344-620 E 4
CH10 A344-620 E 4
CA20 A344-620 E 4
CA25 A344-620 E 4
CA40/C26 A344-620 E 4
CA50/C32 A344-620 E 4
CA63/C42 A344-620 E 4
C80 A344-620 E 4
C125 A344-620 E 4
C200-4 A344-620 E 4
C315 A344-620 E 4

TM
Rotary Cam Switches

Rotary Cam Switches

Changeover Switches

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal Current IU = Ith A 10 20 25 32 40 50
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal Current IU = Ith A 63 115 150 200 315 500
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


Changeover Switches with Centre “OFF” 1 Pole
60° Switching CA10 A210-620 E¹ 1
CH10 A210-620 E¹ 1
CA20 A210-620 E¹ 1
CA25 A210-620 E¹ 1
CA40/C26 A210-620 E¹ 1
CA50/C32 A210-620 E¹ 1
CA63/C42 A210-620 E¹ 1
620E C80 A210-620 E¹ 1
C125 A210-620 E¹ 1
C200-4 A210-620 E¹ 1
C315 A210-620 E¹ 1

BLUE LINE switchgear


2 Pole
CA10 A211-620 E¹ 2
CH10 A211-620 E¹ 2
623E
CA20 A211-620 E¹ 2
CA25 A211-620 E¹ 2

11
CA40/C26 A211-620 E¹ 2
CA50/C32 A211-620 E¹ 2
CA63/C42 A211-620 E¹ 2
C80 A211-620 E¹ 2
C125 A211-620 E¹ 2
BLUE LINE switchgear

C200-4 A211-620 E¹ 2
C315 A211-620 E¹ 2
3 Pole
CA10 A212-620 E¹ 3
CH10 A212-620 E¹ 3
CA20 A212-620 E¹ 3
CA25 A212-620 E¹ 3
CA40/C26 A212-620 E¹ 3
CA50/C32 A212-620 E¹ 3
CA63/C42 A212-620 E¹ 3
C80 A212-620 E¹ 3
C125 A212-620 E¹ 3
C200-4 A212-620 E¹ 3
C315 A212-620 E¹ 3
¹choose part number ending -623 E for MAN-OFF-AUTO - front plate

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 357


BLUE LINE switchgear
BLUE LINE switchgear

Changeover Switches– continued

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal
IU = Ith A 10 20 25 32 40 50
Current
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal
IU = Ith A 63 115 150 200 315 500
Current
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


Changeover Switches 4 Pole
with Centre “OFF”
60° Switching CA10 A213-620 E¹ 4
CH10 A213-620 E¹ 4
CA20 A213-620 E¹ 4

620 E CA25 A213-620 E¹ 4


CA40/C26 A213-620 E¹ 4
CA50/C32 A213-620 E¹ 4
CA63/C42 A213-620 E¹ 4
C80 A213-620 E¹ 4
C125 A213-620 E¹ 4
623 E C200-4 A213-620 E¹ 4
C315 A213-620 E¹ 4
6 Pole

CA10 A362-620 E¹ 6

¹choose part number ending -623 E for MAN-OFF-AUTO - front plate

Gang Switches – Sequence Switching


Function Code No.
OFF/A/A+B 1 Pole
60° Switching
CA10 A310-620 E
OFF/A/A+B 2 Pole
60° Switching CA10 A312-620 E
OFF/A/A+B 3 Pole
60° Switching
CA10 WAA314-620 E
OFF/A/A + B/A + B + C 1 Pole
30° Switching CA10 A311-620 E

TM
Rotary Cam Switches

Changeover Switches– continued

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal
IU = Ith A 10 20 25 32 40 50
Current
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal
IU = Ith A 63 115 150 200 315 500
Current
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


1 Pole
Changeover Switches without Centre “OFF” CA10 A220-600 E 1
60º Switching CH10 A220-600 E 1
CA20 A220-600 E 1
CA25 A220-600 E 1
CA40/C26 A220-600 E 1
CA50/C32 A220-600 E 1
CA63/C42 A220-600 E 1
C80 A220-600 E 1
C125 A220-600 E 1
C200-4 A220-600 E 1
C315 A220-600 E 1
2 Pole
CA10 A221-600 E 2
CH10 A221-600 E 2
CA20 A221-600 E 2
CA25 A221-600 E 2

BLUE LINE switchgear


CA40/C26 A221-600 E 2
CA50/C32 A221-600 E 2
CA63/C42 A221-600 E 2
C80 A221-600 E 2
C125 A221-600 E 2

11
C200-4 A221-600 E 2
C315 A221-600 E 2
3 Pole
CA10 A222-600 E 3
CH10 A222-600 E 3
BLUE LINE switchgear

CA20 A222-600 E 3
CA25 A222-600 E 3
CA40/C26 A222-600 E 3
CA50/C32 A222-600 E 3
CA63/C42 A222-600 E 3
C80 A222-600 E 3
C125 A222-600 E 3
C200-4 A222-600 E 3
C315 A222-600 E 3

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 359


BLUE LINE switchgear
BLUE LINE switchgear

Changeover Switches– continued

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal Current IU = Ith A 10 20 25 32 40 50
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal Current IU = Ith A 63 115 150 200 315 500
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


Changeover Switches without Centre “OFF”
4 Pole
60º Switching
CA10 A223-600 E 4

CH10 A223-600 E 4

CA20 A223-600 E 4

CA25 A223-600 E 4

CA40/C26 A223-600 E 4

CA50/C32 A223-600 E 4

CA63/C42 A223-600 E 4

C80 A223-600 E 4

C125 A223-600 E 4

C200-4 A223-600 E 4

C315 A223-600 E 4

6 Pole

CA10 A370-600 E 6

8 Pole

CA10 A372-600 E 8

TM
RFI Screened Systems

RFI Screened Systems

RFI Gland Plates - for Secure Screen Continuity

Screen cables are designed to contain RFI/EMC


noise that can interfere with surrounding electronic
equipment and severely impair signals and
performance.
When terminating, it is very important that the
screen is not broken, or significantly exposed as
pig tails and steel enclosures easily become aerial
amplifiers.
To overcome this, the use of EMC glands and a K&N
RFI Gland Kit ensures 360 degree bond and insulated
continuity from one gland to the other through the
insulated RFI Bar.

BLUE LINE switchgear


Pig Tail connections and screens bonding to steel
enclosures create aerial amplifiers for RFI noise to be 11
radiated to other electronic equipment.
BLUE LINE switchgear

This is overcome by the use of EMC glands and a K&N


RFI Gland Kit ensures 360 degree bond and insulated
continuity from one gland to the other through the
insulated RFI Bar.

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 361


BLUE LINE switchgear
BLUE LINE switchgear

RFI Screened Systems

RFI Screen Systems for VSD Stainless Steel

316 Stainless steel enclosure with fixed lid & bead blasted finish (IP 66)
With RFI screened systems for VSD
3 Phase load break isolators with integrated 1 N/O & N/C auxilliary contact,
Non-interlocking door clutch and lockout safety handle
RFI gland size Enclosure size
kW Rating Amp Rating Part Number
(mm) (mm)
7.5 25 KG20B.K302*AUN1424*6SS0 2x25 208x113x100
15 40 KG41B.K302*AUN1425*6SS1 2x25 240x140x120
15 40 KG41B.K302*AUN1426*6SS1 2x32 240x140x120
ENCL: 6SS
22 63 KG64B.K302*AUN1425*6SS1 2x25 240x140x120
22 63 KG64B.K302*AUN1426*6SS1 2x40 240x140x120
37 100 KG100.K302*AUN1428*6SS1 2x40 240x140x120
45 125 KG105.K302*AUN1428*6SS1 2x40 240x140x120
45 125 KG126.K302*AUN1430*6SS2 2x50 350x230x170
55 160 KG161.K302*AUN1430*6SS2 2x50 350x230x170

316 Stainless steel enclosure with hinged lid & bead blasted finish (IP 66)
With RFI screened systems for VSD
3 Phase load break isolators with integrated 1 N/O & N/C auxilliary contact,
Non-interlocking door clutch and lockout safety handle
RFI gland size Enclosure size
kW Rating Amp Rating Part Number
(mm) (mm)
90 250 KG251.K302*AUN1431*6SH3 2x50 500x320x175
110 315 KG316.K302*AUN1431*6SH3 2x50 500x320x175 ENCL: 6SH

RFI Screened Systems

RFI Screen Systems for VSD Plastic

Plastic Fixed Lid Enclosure (IP 66) with RFI Screened Systems for VSD
3 Phase load break isolators with
Integrated 1 N/O & 1 N/C auxilliary contact,
Non-interlocking door clutch and lockout safety handle
RFI gland size Enclosure size
kW Rating Amp Rating Part Number
(mm) (mm)
7.5 25 KG20B.K302*AUN1432*6FE 2x20 190x190x130
15 40 KG41B.K302*AUN1432*6FE 2x25 190x190x130
22 63 KG64B.K302*AUN1433*6FE 2x32 190x190x130
30 80 KG20B.K302*AUN1434*6FE 2x40 280x190x130
ENCL: 6FE
37 100 KG100B.K302*AUN1434*6SS1 2x40 280x190x130

TM
Rotary Cam Switches

Rotary Cam Switches

Binary Coded Decimal Switches

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal
IU = Ith A 10 20 25 32 40 50
Current
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal
IU = Ith A 63 115 150 200 315 500
Current
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Binary Coded Decimal Switches – from 1 Volt. CG4-1 = Gold Plated Contacts For PLC and Electronic Applications.
CAD11 = Gold Wiping H-bridge Contacts
CAD12 = Silver Wiping H-bridge Contacts

Front Plate Code No. No of Stages


0-7 Binary
CAD11 A540-600 E 2
CAD12 A540-600 E 2
0-7 Complement
A540
CAD11 WAA541-600 E 2
CAD12 WAA541-600 E 2

BLUE LINE switchgear


0-7 + Complement
CAD11 WAA542-600 E 3
CAD12 WAA542-600 E 3
WAA541 0-11 Binary

11
CAD11 A543-600 E 2
CAD12 A543-600 E 2
0-9 Binary
CAD11 A550-600 E 2
BLUE LINE switchgear

CAD12 A550-600 E 2
0-9 Complement

WAA542 CAD11 WAA551-600 E 2


CAD12 WAA551-600 E 2

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 363


BLUE LINE switchgear
BLUE LINE switchgear

Rotary Cam Switches

Step Switches

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal Current IU = Ith A 10 20 25 32 40 50
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal Current IU = Ith A 63 115 150 200 315 500
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


3 Step Switches without “OFF” 1 Pole
60° Switching CA10 A230-600 E 2
CH10 A230-600 E 2
CA20 A230-600 E 2
2 Pole
CA10 A250-600 E 3
CH10 A250-600 E 3
CA20 A250-600 E 3
3 Pole
CA10 A270-600 E 5
CH10 A270-600 E 5
CA20 A270-600 E 5
4 Pole
CA10 A476-600 E 6
CH10 A476-600 E 6
CA20 A476-600 E 6
5 Pole
CA10 WAA484-600 E 8
6 Pole
CA10 WAA489-600 E 9
4 Step Switches without “OFF” 1 Pole
60° Switching CA10 A231-600 E 2
CH10 A231-600 E 2
CA20 A231-600 E 2
2 Pole
CA10 A251-600 E 4
CH10 A251-600 E 4
CA20 A251-600 E 4
3 Pole
CA10 A271-600 E 6
CH10 A271-600 E 6
CA20 A271-600 E 6
4 Pole
CA10 A477-600 E 8
CH10 A477-600 E 8
CA20 A477-600 E 8

TM
Rotary Cam Switches

Step Switches– continued

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal
IU = Ith A 10 20 25 32 40 50
Current
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal
IU = Ith A 63 115 150 200 315 500
Current
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


5 Step Switches without “OFF” 1 Pole
60° Switching CA10 A232-600 E 3
CH10 A232-600 E 3
CA20 A232-600 E 3
2 Pole
CA10 A252-600 E 5
CH10 A252-600 E 5
CA20 A252-600 E 5
3 Pole
CA10 WAA272-600 E 8
CH10 WAA272-600 E 8
CA20 WAA272-600 E 8
6 Step Switches without “OFF” 1 Pole
60° Switching CA10 A233-600 E 3
CH10 A233-600 E 3

BLUE LINE switchgear


CA20 A233-600 E 3
2 Pole
CA10 WAA253-600 E 6
CH10 WAA253-600 E 6
CA20 WAA253-600 E 6

11
BLUE LINE switchgear

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 365


BLUE LINE switchgear
BLUE LINE switchgear

Step Switches– continued

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal
IU = Ith A 10 20 25 32 40 50
Current
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal
IU = Ith A 63 115 150 200 315 500
Current
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


6 Step Switches cont. 3 Pole

CA10 WAA273-600 E 9

CH10 WAA273-600 E 9

CA20 WAA273-600 E 9
2 Step Switches with “OFF” 1 Pole
60° Switching CA10 A240-620 E 1
CH10 A240-620 E 1
CA20 A240-620 E 1
2 Pole
CA10 A260-620 E 2
CH10 A260-620 E 2
CA20 A260-620 E 2
3 Pole
CA10 A280-620 E 3
CH10 A280-620 E 3
CA20 A280-620 E 3
4 Pole
CA10 WAA480-620 E 4
CH10 WAA480-620 E 4
CA20 WAA480-620 E 4
3 Step Switches with“OFF” 1 Pole
45° Switching CA10 A241-620 E 2
CH10 A241-620 E 2
CA20 A241-620 E 2
2 Pole
CA10 A261-620 E 3
CH10 A261-620 E 3
CA20 A261-620 E 3
3 Pole
CA10 A281-620 E 5
CH10 A281-620 E 5
CA20 A281-620 E 5
4 Pole
CA10 WAA481-620 E 6
4 pole drawing on request CH10 WAA481-620 E 6
CA20 WAA481-620 E 6

TM
Rotary Cam Switches

Step Switches– continued

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal
IU = Ith A 10 20 25 32 40 50
Current
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal
IU = Ith A 63 115 150 200 315 500
Current
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


4 Step Switches with “OFF” 1 Pole
30° Switching CA10 A242-620 E 2
CH10 A242-620 E 2
CA20 A242-620 E 2
2 Pole
CA10 WAA262-620 E 4
CH10 WAA262-620 E 4
CA20 WAA262-620 E 4
3 Pole
CA10 WAA282-620 E 6
CH10 WAA282-620 E 6
CA20 WAA282-620 E 6
4 Pole
CA10 WAA482-620 E 8

BLUE LINE switchgear


CH10 WAA482-620 E 8
CA20 WAA482-620 E 8

11
BLUE LINE switchgear

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 367


BLUE LINE switchgear
BLUE LINE switchgear

Step Switches– continued

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal
IU = Ith A 10 20 25 32 40 50
Current
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal
IU = Ith A 63 115 150 200 315 500
Current
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


5 Step Switches with “OFF” 1 Pole
30° Switching CA10 A243-620 E 3
CH10 A243-620 E 3
CA20 A243-620 E 3
2 Pole
CA10 WAA263-620 E 5
CH10 WAA263-620 E 5
CA20 WAA263-620 E 5
3 Pole
CA10 WAA283-620 E 8
CH10 WAA283-620 E 8
CA20 WAA283-620 E 8
6 Step Switches with “OFF” 1 Pole
30° Switching CA10 A244-620 E 3
CH10 A244-620 E 3
CA20 A244-620 E 3
2 Pole
CA10 WAA264-620 E 6
CH10 WAA264-620 E 6
CA20 WAA264-620 E 6
3 Pole
CA10 WAA284-620 E 9
CH10 WAA284-620 E 9
CA20 WAA284-620 E 9

TM
Rotary Cam Switches - Panel Mounting

Rotary Cam Switches - Panel Mounting

Stop/Start Switches

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal Current IU = Ith A 10 20 25 32 40 50
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal Current IU = Ith A 63 115 150 200 315 500
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


Double Throw Spring
1 Pole
Return to “OFF”
30° Switching CA10 A214-620 E 1

CH10 A214-620 E 1

2 Pole

CA10 A215-620 E 2

CH10 A215-620 E 2

3 Pole

BLUE LINE switchgear


CA10 A216-620 E 3

CH10 A216-620 E 3
Stop Start Switch
1 Pole
30° Switching

CA10 A176-600 E 1
11
CH10 A176-600 E 1
BLUE LINE switchgear

Stop Start Switch Spring return to


1 Pole
“RUN”

CA10 A178-620 E 1

CH10 A178-620 E 1

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 369


BLUE LINE switchgear
BLUE LINE switchgear

Rotary Cam Switches - Panel Mounting & Enclosed

Motor Control Switches

Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CG8, CH10, CA10 CA20, CA20B C26, CA25 CA40 C32, CA50
Rated Thermal
IU = Ith A 10 20 25 32 40 50
Current
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42, CA63 C80 C125 C200-4 C315 L400
Rated Thermal
IU = Ith A 63 115 150 200 315 500
Current
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


Motor Reversing 3 Phase
60° Switching

CA10 A401-620 E 3
CA40/C26 A401-620 E 3
Single/Split Phase
Reversing

CA10 WAA622-600 E 3
CA20B WAA622-600 E 3
Reversing Single or
Three Phase 90° Enclosed
IP65

CA10 C2Y096*PF1 AUS0001 3


CA10 AU9Y96 600FT2 AUS0002 3
Motor Reversing
3 Phase Spring Return

CA10 A228-620 E 3
CA40/C26 A228-620 E 3
Off-Star-Delta

CA10 A410-620 E 4
CA40/C26 A410-620 E 4
Tap wound Motor
(2 speed)

A441
CA20 A441-620 E 4
CH10 A441-620 E 4

TM
Rotary Cam Switches - Panel Mounting & Enclosed

Rotary Cam Switches - Panel Mounting

Meter Switches

CG8
CA20 C26 C32
Selection Data IEC 60947-3, EN 60947, VDE 0660 CA4 CH10 CA40
CA20B CA25 CA50
CA10
Rated Thermal Current IU = Ith A 10 20 25 32 40 50
Rated Category 3x380 V/440 V AC-23A kW 3 7.5 11 15 18.5 22
C42
C80 C125 C200-4 C315 L400
CA63
Rated Thermal Current IU = Ith A 63 115 150 200 315 500
Rated Category 3x380 V/440 V AC-23A kW 30 45 75 75 132 132

Function Front Plate Code No. No. of Stages


Meter Switches 3 Phase – 3 Wire

A004

CA10 A004-625 E 2
CH10 A004-625 E 2
3 Ph – Ph / 3 Ph – N

BLUE LINE switchgear


A007

11
CA10 A007/AU2122 E 3
1 Pole – 3 Current Transformers
BLUE LINE switchgear

A058

CA10 A058/AUN0180 E 3
CH10 A058/AUN0180 E 3

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 371


BLUE LINE switchgear
BLUE LINE switchgear

Rotary Cam Switches

Optional Extras

Keylocks Code Mounting Units Code


Direct Drive Operator V750/A9 Panel mount 2 or 4 screw E
without key barrel

For base mounting V750D/VE21 Panel mount 2 or 4 screw IP65 EFA

V750D/3 Base mounting 4 screw mount VE

IP 66
For single hole 22 mm
Standard K&N Key

V755/6CL Base mount DIN rail VE1

Direct Drive Key Operator


Mounted in a IP66
Hinged/ Flip Lid
Enclosure

6S0LW V755/A Base mount DIN rail with MCB cut out VE2
Direct Drive Key Operator

Nominate key barrel:-


570 Lockwood, Bi-Lock, Lock Focus,
KabaQuattro, Efco, Schlage, CL, etc
Customised key systems:-
Key indication, cylinder removable
from front (RL), Electronic key
Double end mount 4 screw fixing ER
interlocks, etc.

Nominate Mounting:-
Panel mount, Wall Plate mounting,
enclosed (plastic, stainless steel etc.)

TM
Optional Extras

Rotary Cam Switches - Panel Mounting & Enclosed


Keylocks Code Mounting Units Code
Optional Extras – continued
E
Direct drive operator V750/A9 Panel mount 2 or 4 screw
Keylocks Code Mounting Units Code
Separate Drive Key Lock V760/A.E Double end mount for fixing of plate with DIN VE1E
Programmable locking positions using A760/A mounting
Strebor barrel For base mounting VE21 Panel mount 2 or 4 screw. EFA
V750D
IP65

VE
For single hole 16/22mm Base mounting
V750D/1
Security
Separate Drive Key Lock key IP66 4 screw mount FS1,
Programmable locking positions for: Single hole without plate FT1
Lockwood 5-6 pin barrels C4 (201). Bi-Lock 16/22mm (FS1)
(specify). For single hole 16/22mm 22/30mm (FT1) VE1
(specify) Includes:Standard
Kraus &K&N
Naimer. V750D/2 Base mount DIN rail
key
Standard barrel:-
6S1 V760 S (Lockwood type). SO V760/A.E
VE2
For single hole 22mm Base mount DIN rail
V750D/3 IP66 with MCB cut out FS2,
Standard K&N key
Single hole square plate FT2
16/22mm (FS2)
22/30mm (FT2) VE1E
Separate drive key lock Double end mount for fixing of esc.
V760/AE plate with DIN mounting base
Standard K&N key

ER
Separate drive key lock Double end mount for fixing of esc.
Yale type key V760/A
plate with screw mounting base
Mounting Units Code Mounting Units Code
Right Angle Drive K3 M330/A Next size upon handle and plate EG
K3 M330/B Single hole
With half-cylinder lock V765 without esc plate 16/22mm FS1
22/30mm FT1

5 pin Barrel Single hole square plate 16/22mm FS2


9 201/5P
22/30mm FT2

BLUE LINE switchgear


Terminal Covers
Spare Keys Ronis (601) S00 V750 S2
3 main contacts:Standard K&N Single hole
Next with plate
size up 16/22mm
handle and plate EG
FS4
K&N (KN101) S0C V750 S2
KG 20 – KG 100 M160 / 3 Rectangle 30x39 (FS4) FT6
KG 126 / KG 161 Spare Keys M160 / 33 Single hole with plate 16/22mm FH4,
KG 251 / KG 316 Security M160Kaba
/ 4EG0031 Rectangle 48x59 (FT6)

11
Single hole with plate 16/22mm
Single hole with plate 16/22mm
Rectangle 30 x 39 FS4
Rectangle 64x78
Single hole(FH4)
with plate 16/22mm
Special Engraving Rectangle 48 x 59 FT6
$14.90 AUTO SELECT
Header Single
2 Lineshole
(PRC)
with plate 16/22mm
Header Rectangle 64 x 78
3 Lines (PRA) FH4
BLUE LINE switchgear

PRC
PRA

18 Free Phone 0800 736 522


4 main contacts
KG 20 – KG 100 M160 / 43
KG 126 / KG 161 M160 / 43
KG 251 / KG 316 M 160 / 41

Please contact your local office for complete switch price and part number.

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 373


xtras
BLUE LINE switchgear
BLUE LINE switchgear

Optional Extras – continued


Code Door Clutch & Shaft Extensions C
nal Extras Padlocks Code Door Clutch & Shaft Extensions Code
The padlock is an integral part of V840A Door clutchDoor clutch
for misaligned doors withfor misaligned
M700
is an intergral the switch handle
V840A doors with locking handle
locking handle
Note: Knowledgeable personnel using a
M700
Note: Knowledgeable personal using a simple
witch
ck handle Code Door
simple tool are ableClutch & Shaft Extensions
to defeat the interlock
tool are able to defeat the interlock
Code
Refer to Page 19
Door clutch for misaligned
adlock is an intergral V840A doors with locking handle M700
Note: Knowledgeable personal using a simple
f the switch handle Door clutch with
tool are able to defeat the interlock M280E
Locking handle for DIN cutout V840B Door clutch with shaft extension Interlocked M280E
dle for handles V840B shaft extension
Refer Available
or Non Interlocked to Page 19
andles Interlocked or
Nonclutch
Door Interlocked
with Available M280E
ng handle for V840B shaft extension
utout handles Interlocked or
Non Interlocked Available
For 4 padlocks V845 IP66
ks V845 Single hole 22mm door V840G/B
clutch and locking handle
IP66
padlocks V845 Single hole 22mm door V840G/B
clutch and locking handle

intergral V840D
Padlock with integral flat or raised
handle – 2 padlock
V840D
IP66
handle - Single hole 22mm door V840G
ck with intergral V840D IP66
raised handle -
clutch and locking handle
Single hole 22mm door V840G
ock clutch and locking handle
Padlock with integral flat or raised V840G/B
handle – 3 padlock
integral V840G/B IP66
ckhandle
with integral
- V840G/B IP66
Single hole 22mm door V845
raised handle - Single hole
clutch and22mm doorhandle
locking V845
ock clutch and locking handle
Padlock with integral flat or raised V840G
handle – 4 padlock

ckintegral
with integral V840G
V840G Single
Single hole
hole 22mm
22mm doordoor V840EV840E
handlehandle
raised - - clutch
clutch and
and locking
locking handle
handle
ock

ck device V850 Single hole 22mm door clutch M295A


ce V850 Single hole 22mm door clutch M295A
TM
Rotary Cam Switches - Panel Mounting & Enclosed

Optional Extras – continued

Padlocks Door Clutch & Shaft


Code Code
Extensions
Padlock device V850 Shaft extensions asymmetric profile M004D

Shaft locking device V840VE Shaft extensions square profile L100A/M004E

Heavy Duty 6SS V840


Stainless Steel
Lock-out safety device

Clip on aux contacts – base mount

BLUE LINE switchgear


For KG20 – KG32 K0-H010/A11-VE
For KG41 – KG64 K1-H010/A11-VE

Clip on aux contacts – panel mount

11
For KG20 – KG32 K0-H010/A11-E
For KG41 – KG64 K1-H010/A11-E
BLUE LINE switchgear

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 375


BLUE LINE switchgear
BLUE LINE switchgear

Additional Switches

Additional Switches
Panel Mount and Enclosed On-Load Fault
Make Load Break Isolators, Disconnectors,
Local Maintenance Safety Switches and
Changeover Switches
Additional Switches
Dimensions mm
Dimensions mm
mm KG Main Switches
KG Main
KG Main Switches Switches A B C D1 D2 F G H L M1 M2 M3
Panel Mounting
tches Panel
Panel Mounting
Mounting
Pole34 and
Pole4 Pole KG10A
3 and34and 48 36 4 11 5 48 48 50 48.2
A B C D1 D2 F GA H B L CM1 M2 D1 M3D2 F G H L M1 M2 M3
Cmax Cmax G M1 G M1 48
KG20A, KG32A 3636 4 411 5 48 10 48 50 5 48,2 48 42 54 53.8
A B C D1 D2 F GKG10AH L M148 M2 M3
G M1 KG10A
KG20B, KG32B KG20A, 64
KG32A 48 4848 KG20A,
36 4 410 KG32A
10 5 10 4248 54 36
48 42 5 53,8 413,5 64
48 54 36 53,8 4 11 5
42 48 42
48
54 54 53.8
48 50 48,2
13.5 9 2
KG10A 48KG20B,
50 KG32B
48,2 64 4 5 64 910 2 5 53,8
Dimensions mm
48 36 4 11 5 48
36KG41B, KG64B 64
53,8 64 48 410 10 70 5 70,6 64 5 50 64 64 54 60.5
53,8 13,5 9 16 12.5 16
KG41B, KG64B 64 48 4 10 5 64 50
KG20A, KG32A 48 4 10 5 48 42KG80,54KG100 KG20B, KG32B 64 64 48 60,5 16
4 12,5 16
10 42 2
48 4 5 70 80 22 10 25
KG20B, KG32B 64 48 4 10 5 64 42KG126,
54 KG161
53,8 13,5 9 KG41B,
2 KG64B 64 48 4 10 5 64 50 64 60,5 16 12,5 16
48KG80,4 KG100 64 4868 16 413KG100 10 145 5 103 452,5 70 5 x 270 70 80 80 70.6 1022 10 25
88 68 5,5 13 6 - 112 108 96 38 21 22
KG41B, KG64B KG80,
H

64 10 5 64 50KG251,
64 KG316
60,5 16 88 12,5 5,5 6 - 64 12648 10 24,5
21 70 70,6 22 25
KG Main Switches KG80, KG100
KG126, KG161
64
68KG126,
48
5,5 KG
4
13 161
10 5 70
112 108 88
70 80 70,6 22
M1 =68 22 5.5
10 KG126,
25 KG161 13 88 6 Block
68 5,5 13 - 6 112- 108 108 96
112 96 38 2138 22 21 22
88
Dimensions 6 - 96 38 Extra
21 Length 4th Pole / Neutral Contact / Earth
H

- mm
KG251, KG316 88 68 5,5 13 6 - 145 126 103 52,5 21 24,5 x 2
Panel Mounting
H

KG251, KG316 M2 = Extra


21 Length
24,5 xTop
2 Mounted Auxilliary Contacts
88 68
KG 5,5
251, 13
KG316 6
88
145 126 103 52,5
M3 =68 5.5
Extra Length 13
Terminal Cover 6 - 145 126 103 52.5 21 24.5x2
3 and 4 Pole M2 L F M1 = Extra Length 4th Pole / Neutral Contact / Earth Block
KG
M1 = Extra Main
Length Switches
4th Pole / Neutral Contact / Earth Block
A B C D1 D2 F G H L M1 M2 M3
Cmax G= ExtraPanel
M2 M1 Mounting
Length Top Mounted Auxilliary Contacts M2 = Extra Length Top Mounted Auxilliary Contacts
M3 = Extra Length Terminal Cover M3 = Extra Length Terminal Cover
L F
3 and 4 Pole KG10A 48 36 4 11 5 48 48 50 48,2
M2 L F A B C D1 D2 F G H L M1 M2 M3
Cmax KG20A, KG32A 48 36 G M1
M1 = Extra Length 4th Pole/ Neutral Contact/64
KG20B, KG32B
Block44
Earth48 10
10
5
5
48
64
42 54
4248 54
53,8
KG10A 36 453,8 1113,5
5 9 48 248 50 48,2
Base Mounted M2 = Extra Length Top KG41B,
MountedKG64B
Auxilliary Contacts
64 48 4 10 KG20A,
5 KG32A
64 5048 64
36 460,5 16
10 5 12,5
48 16
42 54 53,8
3 and 4 Pole
KG20B, KG32B
KG80,Cover
M3 = Extra Length Terminal KG100 7064M280
48 4 10 5 1064 42 54 53,8 13,5 9 2
A64 B 48C 4D1 10
D2 G 5 H 70L M1 M3 70,6 22 25
KG41B, KG64B 64 48 4 10 5 64 50 64 60,5 16 12,5 16
Note : 6 Pole width = 3 Pole width x 2 KG126, KG161 88 68 5,5 13 6 KG100
KG80, - 112
64 108
48 496 1038 5 2170 22
70 80 70,6 22 10 25
KG10
H

48 36 12 8 5 48 50 49,2
KG251, KG316
KG20A, KG32A
88 36
48
6812 5,5
8 5
13 6 54 KG161
KG126,
42
- 50 145
88 126
68 103 1352,5
5,5 6 21- 38 24,5
112 x108
21 22 2 96
H

G M1 KG251,
KG20B, KG32B 54 KG316 13,588- 6820 5,5 13 6 - 145 126 52,5 21 24,5 x 2 103
Base
Cmax
Mounted A B C D1 D2 G HKG41B,
L KG64B
M1
64
M2
48
M1 M3
64 =
13,5 10
48Extra
13,5Length
10
5 42
54th Pole
50
50
/ Neutral
64 61 Contact
16 10 / Earth
16 Block
3 and 4 Pole KG80, KG100 64 48 13,5 10 5 70 80 68 22 M110= Extra
25 Length 4th Pole / Neutral Contact / Earth Block
3 Pole width x 2
Base MountedKG10 48 36 12 8 5 48
KG126, KG161
50 49,2 A 88 B
M2 =
Dimensions mm
68
Extra
16
Length
13 6
Top 112
Mounted
A 91 B 38 M3
108 C
Auxilliary
M2Contacts
C0
= Extra
22 D1
D1 D2 G D2 H L G
Length Top Mounted Auxilliary Contacts
M1 M2 M3 H L M1 M2 M3
M3 =
68Extra
16 Length 6Terminal Cover
Dimensions 52,5 0 = Extra Length
x 2 Terminal Cover
A

KG251, KG316 88 13 145 126 98 24,5


G M1 M2 3 and 4LPoleNote : 6KG20A,
Pole width =mm
KG32A 3 Pole
48 width
F
36 x 2
KG10A
12 M28 5 L42 54 50
48 F 36 12 8 5 48 50 49.2
KG20B, KG32B 64 48 13,5 10 5 42 54 50 13,5 KG
- M1 Main Switches
20 KG10 48 / Earth
36 Block
12 8 5 48 50 49,2
Note: 6 Pole Width
KG= 3 Pole
Main Width x 264 48 13,5 KG20A,
Switches 5 KG32A M2 =48
= Extra Length 4th Pole / Neutral Contact
36KG32A mm 1248 36 8 12 85 5 4242 54 5450 50
KG41B, KG64B 10 50 64 61 Panel
1016 Mounting
16 KG20A,
Extra Length Top Mounted Auxilliary Contacts
M2Panel LMounting
KG80, KG100 64 48 13,5 G10 5M1 70 80 68 310
and Dimensions
M34=Pole
22 25
Extra Length Terminal Cover
KG20B, KG32B 64 G 48 M113,5 10 5 42 A 54 B 50 C D113,5
D2 -F G 20H L M1 M2 M3
Cmax
KG126, KG161
3 and 4 Pole
CmaxKG316
88 68 16
G
KG20B,
13
M1
6 KG32B 112 108 91 B
0 C64
38
A
Cmax
22 D1 KG41B,
KG D2
Main F 48KG64B
G
Switches H L13.5 M1 M2 48
64 M310 13,5 105 5 4250 64 5461 16 50 10 1650 13.5 - 20
KG251, 88 68 16 13 6 145 126 98 0 52,5 24,5 x 2 KG10A 48 36 4 11 5 48 48 48,2

Padlock Device V840G


KG41B,
Padlock
KG64B KG10A 48 36 4 64 11 KG80,
Panel 4848
5 MountingKG100
48 50
Dimensions 13.5
48,2 64
mm
4810 13,5 10 5 5 KG32A
KG20A,
50
70 4880 36 6468 4 10 225
61
10
48 42 2554
1653,8
102 16
4th Pole /Device V840G 5 Padlock Device 53,8 V845
Base
M1 = Extra LengthMounted KG20A,
NeutralKG20B,
Contact
KG32A 48 36
/ Earth64Block
KG32B
4 3
10 and 4 Pole
KG126, 48
KG161
42 54
88 68 16 13 KG20B, KG32B
6
KG41B, 112
KG64B
64
108 48
A 48 B 91
4 10
C 10D1 385
D2 0
64
F
42
G 22H
54 53,8 13,5 9
L60,5 M1 M2 M316
KG80, KG100 4 64 10 KG251, 6448 13.5 1610 16 5 KG80, 70145 64126 48 80 68 80 22 2 22 10 1025 25
36 mm sq. Fixation 48 mm sq. Fixation 48 4 10 5 64 42 54
Cmax sq. Fixation
68mm 53,8 13,5 9 2 G M1 64 4 5 64 50 64 16 12,5
A

3 and
M2 = Extra 4 Pole
Length Top Mounted Auxilliary
KG41B,Contacts
KG64B 64 48 5 KG316
50 64 60,5 88
16 12,568 13 KG100
6 KG10A 98
4 10 52,5
5 0
70 70 24,5 x48,2
70,6
Base Mounted KG10, KG20, KG32
M3 = Extra Length
KG10B, KG20B, KG32B,
Terminal Cover KG80,KG41B,
KG100 KG64B,
64 48 4 10 5 KG126,
70 KG
70 Main
KG161,
80 Switches
KG251,
70,6 22KG316
10 25 A B C D1
KG126, KG161D2 G
88 48 H
68 36
5,54L 11 M1
13 6 5
-M2
48 48M3 50
112 108 96 38 21 22
KG126, =KG 161 88 66 -- 68 145 1652,5 13 6 Pole 112 88 64 68108 5,54 1310 6 5 91 54 38
52,5 9 21 20 24,5 x 2 22
KG80, KG100, Panel Mounting KG20A, KG32A 48 36 4 10 5 48 42 54 53,8
3KG105 KG126,xKG161
H

Note : 6 Pole width Pole width 2 88 68 5,5 13 112 108 96 38 21 22 KG251, KG316 - 64 145 126 53,8
103 13,5
3 and 4 Pole 9KG20B, KG32B 48 42
H

KG251, KG316 88 68 5,5 13 3 and 126


4 Pole 103 21 24,5 x 2
KG10M1 = Extra Length 48 364th 12 8/ Neutral
KG41B, KG64B
5 Contact
4864 50 48 / Earth
449,2A10 Block
B5 C64 D150 D264 F 60,5G 16 H 12,5L 16 M1 M2 M3
A 4th B C ContactD1 CmaxD2 G H 48 L36 G 12 M1M1 8 M2 KG100 M3
KG 251, KG316 88 68 16 13 6 145 126 13 366 98 10852.5 0 24.5x2
KG80, M1 = Extra
48Length
4 4th10Pole5/ Neutral
70 Contact / Earth Block
KG20A, M2KG32A
= Extra Length Top Mounted 5 42=64Extra
Auxilliary 54 50 Mounted 70 80 70,6 22 10 25
G M1M1 88 Contacts
= Extra Length Pole / Neutral / Earth Block KG126, KG161 M2 68Length
5,5 Top Auxilliary
- 112 Contacts 96 4838 5021 48,2 22
Note : 6 Pole width = 3 Pole width x 2 KG10A 48 4 11 5 48
KG20B, KG32B
M2 = Extra Length Top Mounted Auxilliary Contacts 64 48 13,5 KG251,
10 KG316
5 42 54 50Terminal
13 13,5 - 10145 205 126 48103 4252,55421 53,8
H

Cmax M3 = Extra Length Terminal Cover M3 =


88Extra68Length 366Cover
ce V840G Padlock Device V840G Padlock Device V845 KG20A, KG32A 5,5 48 4- 24,5 x 2
M2 L KG10 48 M3 = Extra Length
36 12M2Terminal Cover
8 KG41B,
L 5 KG64B
48
F 5064 49,2
48 13,5 10 5 50
KG20B, 64
KG32B 61 64 16 48 410 10 165 64 42 54 53,8 13,5 9 2
M2 L F M1 = KG64B
Extra Length644th Pole
48 / Neutral Contact
48 mm sq. Fixation 68mm sq. Fixation
KG20A, KG32A48 36 12 8 KG80, 5 KG100 42 5464 50 48 13,5 10 5 KG41B,
70 80 68 Top 22 410 10 255 / Earth
64 Block
50 64 60,5 16 12,5 16
KG80,
M2 =KG100
Extra Length64 Mounted
48 4 Auxilliary
10 Contacts
5 70 70 80 70,6 22 10 25
KG10B, KG20B, KG32B, KG41B,GKG64B,M1 KG126, KG161, KG251, KG316 KG126, KG161 88 68 16 13 6 112
KG126, 108
M3 = KG161 91 88Terminal
38 0 13 226
KG20B, KG32B
Extra Length 68 Cover
5,5 - 112 108 96 38 21 22
Cmax 64 48 M2 13,5 10 5 KG316 42 F 5488 50 13,513- 6 20145
A

KG251,
H

KG80, KG100, KG105 L 68 16 KG251, KG316


126 98 88 52,5 68 0 13 24,5
5,5 6 x2 - 145 126 103 52,5 21 24,5 x 2
KG41B, KG64B 64 48 913,5 10 5 50 64 61 16 10 16
Padlock Device V840G M1 = Extra Length Padlock
KG80, 4thKG100 Device
Pole/ Neutral 64 V840G
Contact/ 48 Earth 13,5Block 10 5 70 Padlock
80M1 = 68
Extra Length
22 4th10Device V845
Pole / Neutral
25 Contact / Earth
M1 = Extra Length 4th Pole / Neutral Contact / Earth Block
Block
M2 = Extra Length Top Mounted Auxilliary Contacts
36Base
mm Mounted
sq. Fixation 48 mmKG161 Base Mounted
sq. Fixation M2 = 68mm
Extra sq. Fixation
73 Length Top Mounted Auxilliary Contacts M3 = Extra Length Terminal Cover
KG126,
M2 = LExtra Length Top Mounted 3Auxilliary
and884 Pole 68 Contacts 16 13 M2 6 L 112 108 91 38 0 22
3 and 4 Pole
KG10, KG20, KG32 KG10B, KG20B, KG32B, KG41B, ExtraF Length
M3 = KG126, TerminalKG251,
Cover KG316
16KG64B, KG161,
A

M2
KG251, KG316 A B 88
C D168D2 G 88
H 13 L 6 M2 145
M1 M3 126 98 52,5 0 A
24,5 xB2 C D1 D2 G H L M1 M2 M3
Note : 6 Pole width = 3 Pole width x 2 M3 = Extra Length Terminal
KG80, KG100,CoverNote : 6 Pole Base
width
KG105 3 and 4 Pole Mounted
= 3 Pole width x 2
KG10 48 36 12 8 5 48 50 49,2
KG10 48 36 12 8 5 48 50 49,2
KG20A, KG32A 48 A 36 B 12 C 8 D1 5 D2 42 G H
54 L
50 M1 M2 M3
9
KG20A, KG32A 36 M1 12 =8 Extra 5 Length
width = 3 4th
G M1 48 42 54 50 Pole
G x 2 /M1Neutral Contact / EarthKG20B,BlockKG32B 64
Note : 6 Pole Pole width
Cmax Padlock Device V840G KG20B, KG32B
KG41B, KG64B
64 48
48 M2
Padlock
13,5Cmax
10
13,5 =10Extra
5
Device
42
Length
54
Top V840G
50 13,5 -
Mounted
20
Auxilliary Contacts KG41B,Padlock
KG64B Device
KG10 64 48 48 V845
48 13,5 10
36 13,5
12 108
5
55
42
48
50
54
50
64
50
49,2
61
13,5 -
16 10
20
16
Door Interlock M280E 48mm sq. Door Interlock KG80,
M280E
64 5 50 Base
64 61Mounted
16 10 16
KG10064mm 64 sq. Door 70 Interlock M280E 88mm sq.
36 mm sq. Fixation KG20A,
sq.KG32A 48 36 12 8 5 42 54 50
13,54810
M2 L 36 mm sq. Fixation KG10, KG20,
48
sq. Fixation KG126, KG161
48mm KG32
M3 = mm 5sq.
Extra
16 KG10B,
Fixation
Length
Cmax
668mm
80
3 and
112sq.KG32B,
KG20B,
68
4 Pole 22
Terminal
Fixation
91 KG41B,
10G 25
Cover
0 KG64B,
M1 68mm
KG80, KG100 Fixation
KG20B, KG32B
64
64
48
KG126,
48
13,5 10
KG161
KG126,
13,5 10
KG161,
5
5
70
42
80
54
68
50
22
13,5 -
10
20
25
88 68 13 108 38 22 KG41B, KG64B 88KG251,
64 68 48 KG316
16 13,513
A10 6
B5 C112
50 D1 108 91 G 16
64 D261 38 H 100 L 1622M1 M2 M3
A

KG251, KG316
A

KG10, KG20, KG32 KG10, KG20, KG32,KG251,


KG41,KG316 88 KG100
KG64, KG80, 68 16 KG80,
13 KG100,
6KG126,
145KG105
126
Note : 98
KG161, Pole52,5
6 KG251, 0= 3 Pole
widthKG316 24,5 x 2x 2
width KG80, KG100 88 64 68 48 16 13,51310 6 5 145
70 126
80 98 22
68 52,5 100 2524,5 x 2
73 KG126, KG161 KG10
88 68 16 4813 366 12112 8 108 5 91 48389 500 49,2
22
KG20A, KG32A 4813Pole
366/ Neutral
12145 8 126 5 98 4252,5540 5024,5 x 2
A

M1 = Extra Length 4th Pole / Neutral Contact / Earth Block G M1 KG251, KG316 M1 = Extra
88 68Length
16 4th Contact / Earth Block
M2 = Extra Length Top Mounted Auxilliary Contacts KG20B, KG32B
M2 = Extra Length Top Mounted Auxilliary Contacts 54
64 48 13,5 10 5 42 50 13,5 - 20
88 Cmax

Padlock Device V840G Padlock Device V840G Padlock Device V845


M3 = Extra Length Terminal KG41B,= KG64B 64 48 Cover13,5 10 5 / Earth
50 Block
64 61 16 10 16
L Cover M3 M1 Extra
= Extra Length
Length 4th Pole
Terminal / Neutral Contact
Padlock Device V840G Padlock Device V840G Padlock Device V845
M2 L M2 KG80, KG100
M2 = Extra Length64 48
Top Mounted 13,5 10 Contacts
Auxilliary 5 70 80 68 22 10 25
KG126,
M3 =KG161
Extra Length88 68 Cover16 13 6 112 108 91 38 0 22
36 mm sq. Fixation 48 mm sq. Fixation 68 mm sq. Fixation
L M2 Terminal
A

36 mm sq. Fixation 48 mm sq. Fixation 68mm sq. Fixation KG251, KG316 88 68 16 13 6 145 126 98 52,5 0 24,5 x 2

Padlock Device V840G Padlock Device V840G Padlock


Padlock Device Device
V840G V845 Padlock Device V840G Padlock
M1 = ExtraDevice
Length 4thV845
KG10, KG20, KG32 36 mm sq. Fixation
KG10, KG20, KG32 KG10B, KG20B, KG32B,
48 mm sq. Fixation KG10B, KG20B, KG32B,
KG41B, KG64B,
mmKG41B,
68mm KG64B,
sq. Fixation
KG126, KG161, KG251,
Fixation Device V840G KG126, KG161, KG251,
KG316
M2 =sq. KG316
Extra
Pole / Neutral Contact / Earth Block
Length Top Mounted Auxilliary Contacts
k M280E 48mm sq. Door Interlock M280E
KG10, KG20,64mm
KG32 sq. Door
KG80, KG100, Interlock
KG10B, KG20B, KG32B,M280E
KG105 88mm sq.36
KG41B, KG64B,
sq. Fixation
KG10, KG126,
Padlock Device
KG161, KG251, V840G
KG316
48 mm sq.
Padlock 68mm
Padlock Fixation
M3 = Extra Device V845Cover
KG80, KG100, KG105 KG20,36KG32 L KG10B, 48
KG20B, KG32B, KG41B, KG64B, Length Terminal
48mm sq. Fixation KG80,
68mm sq.KG100, KG105
Fixation
mm sq. Fixation
KG10, KG20, KG32
M2
mm
KG80,9KG100,
sq. Fixation
KG10B,KG105
KG20B, KG32B, KG41B, KG64B,
9 KG126,
68mm KG161, KG251,
sq. Fixation KG316
73
KG126, KG161, KG251, KG316
9
KG10, KG20, KG32, KG41, KG64, KG80, KG100 KG126, KG161, KG251, KG316 KG80, KG100, KG10588 9
Padlock Device V840G Padlock Device V840G Padlock
73 Device V845
36 mm sq. Fixation 48 mm sq. Fixation 68mm sq. Fixation
KG10, KG20, KG32 88KG32B, KG41B, KG64B,
KG10B, KG20B, KG126, KG161, KG251, KG316
KG80, KG100, KG105
9

SingleDoor Interlock
Hole Mounting M280E
FS1/FS2 48mm sq. Door Interlock
Single M280E
Hole Mounting 64mm sq.
FT1/FT2 Door Interlock M280E 88mm sq.
(Size36
00)mm sq. Fixation Door Interlock M280E 48mm
48mm sq.0)
(Size
sq. Fixation Door Interlock M280E 64mm
73 sq. 68mm sq.Door Interlock M280E 88mm sq.
Fixation
88 7373
KG10, KG20, KG32 36 mm sq. Fixation 48mm sq.
KG10, KG20, KG32, KG41, Fixation
KG64, KG80, KG100 68mm sq.KG251,
KG126, KG161, Fixation KG316
8888
KG10, KG20, KG32 KG10, KG20, KG32, KG41, KG64, KG80, KG100 KG126, KG161, KG251, KG316

Door Interlock M280E


Interlock 48mm sq.sq. Door Interlock M280E 64mm M280Esq. Door
73 Interlock M280E 88 88mm sq.
73
Door M280E 48mm Door Interlock M280E 64mm
To sq.
accomodate Door Interlock 88mm sq.
Door Door Interlock
Interlock M280E sq.
M280E 48mm 48mm sq. Door Door Interlock
Interlock M280E M280E
64mm64mm sq. DoorInterlock
Interlock M280E
M280E 88mm
88mmsq.
36 mm sq.To
Fixation
accomodate
36 mm sq. Fixation
KG10,
16.2 in 22.3 HoleKG20, KG32
48mm sq. Fixation
48 mm sq. Fixation
KG10, KG20, KG32, KG41, KG64, KG80,
68mm
22.3KG100
in 30.5
Hole
sq. Fixation
36 mm sq. Fixation
KG126,
36 mm
88
KG161, KG251, KG316
sq. Fixation
48mm sq. Fixation
48mm sq. Fixation 68sq.mm sq. Fixation
Door
68mm sq. Fixation
68mm sq. Fixation
sq.
S0E T160 - 01KG10, KG20,KG10, KG20, KG32 KG10, KG20, KG32, KG41, KG64, KG80, KG100 KG126, KG161, KG251, KG316
KG10, KG20,
S00KG32 KG41B, KG64B, KG80, KG100 KG126, KG161,
64mm KG251, KG316
KG32 KG10, KG20, KG32, KG41, KG64, KG80, KG100 KG126, KG161, KG251, KG316
T160 - 01
Door Interlock M280E 48mm sq. Door Interlock M280E sq. Door Interlock M280E 88mm sq.
36 mm sq. Fixation 48mm sq. Fixation 68mm sq. Fixation
KG10, KG20, KG32 KG10, KG20, KG32, KG41, KG64, KG80, KG100 KG126, KG161, KG251, KG316

unting FS1/FS2 Single Hole Mounting FT1/FT2


Door Interlock M280E 48mm(Size
sq.0) Door Interlock M280E 64mm sq. Door Interlock M280E 88mm sq.
36 mm sq. Fixation 48mm sq. Fixation 68mm sq. Fixation
KG10, KG20, KG32 KG10, KG20, KG32, KG41, KG64, KG80, KG100 KG126, KG161, KG251, KG316

To accomodate
22.3 in 30.5 Hole Single Hole Mounting FS1/FS2 Single Hole Mounting FS1/FS2 Single Hole Mounting FT1/FT2
Single Hole Mounting FT1/FT2
Single Hole Mounting
Single Hole
FS1/FS2
(Size 00) S0E T160
Mounting
- 01
FS1/FS2
(Size 00)
Single Hole Mounting FT1/FT2
(Size 0) (Size 00)
Single
Single Hole Mounting FS1/FS2Hole (Size 0)
Mounting 29(SizeHole
FT1/FT2Single 0)
Mounting FT1/FT2
(Size 00) Single Hole Mounting FS1/FS2 (Size 00) (Size 0) Hole Mounting FT1/FT2 (Size 0)
Single
Single Hole Mounting FS1/FS2
(Size 00)
Single Hole Mounting FT1/FT2
(Size 0)
(Size 00) To accomodate
(Size 0)
To accomodate
To accomodate
22.3 in 30.5 Hole
To accommodate To accomodate
16.2 in 22.3 Hole To accomodate
22.3 in 30.5 Hole
S0E T160 - 01 S00 T160 - To01 accommodate
16.2 in 22.3 Hole
To accomodate S0E T160
To accomodate
- 01
S00 T160 - 01 To accomodate 22.3 in 30.5 Hole To accomodate
16.2 in 22.3 Hole 16.2 in 22.3 Hole
S00 T160 - 01
16.2 in 22.3 Hole 22.3 To16.2
inaccomodate
30.5 Hole
in 22.3 Hole S0E T160 - 01
22.3 in 30.5 Hole
S0E T160 - 01
22.3 in 30.5 Hole
S0E T160 - 01
S00 T160 - 01
S00 T160 - 01 S0E T160 - 01
S00 T160 - 01

To accomodate
To accomodate 22.3 in 30.5 Hole
16.2 in 22.3 Hole S0E T160 - 01
S00 T160 - 01
Single Hole Mounting FS1/FS2 Single Hole Mounting FT1/FT2
29 29
(Size 00) (Size 0) 29
29
TM
29
29
To accomodate
KG Main Switches

KG Main Switches

Padlockable Panel Mount, Enclosed Plastic or Stainless Steel

Selection Data Switch Type KG125 KG160 KG210 KG250 KG315


IEC 60947, EN 60947, VDE 0660 KG10 KG20 KG32 KG41 KG64 KG126 KG161 KG211 KG251 KG316
KG80 KG100 KG105
IEC 204, EN 60204, VDE 0113 KG10B KG20B KG32B KG41B KG64B KG127 KG162 KG212 KG252 KG317
Nominal
Ui V 690 690 690 690 690 690 690 690 1000¹ 1000¹ 1000¹ 1000¹ 1000¹
Voltage
Thermal
IU/Ith A 20 25 32 40 63 80 100 125 125 160 200 250 315
Current
Enclosed
thermal Ithe A 20 25 32 40 63 80 100 125 125 160 200 250 315
current
Operational
Current Ie A 20 25 32 40 63 80 100 125 125 160 200 250 315
AC21A
Utilisation
Category 3 x
kW 5.5 7.5 11 15 22 30 37 45 45 55 75 90 110
380V / 440V
AC-23A/B

¹suitable for no load switching (AC-20A) above 690V.

Product Code No.


Panel Mount – Lockable 3 Pole (ESC OFF-ON) V840G/D
Panel Mount IP65 KG10B K300*AU2100 E
Red / Yellow Padlock Handle - V840G/D KG20B K300*AU2100 E
KG32B K300*AU2100 E
KG41B K300*AU2100 E
KG64B K300*AU2100 E

BLUE LINE switchgear


KG80 K300*AU2100 E
KG100 K300*AU2100 E
KG105 K300*AU2100 E
KG126 K300*AU2100 E
KG161 K300*AU2100 E

11
KG211 K300*AU2100 E
KG251 K300*AU2100 E
KG316 K300*AU2100 E
Panel Mount - Lockable 3 Pole + 1 N/O 1 N/C Aux. V840G/D
BLUE LINE switchgear

KG10B K302*AU2100 E
KG20B K302*AU2100 E
KG32B K302*AU2100 E
KG41B K302*AU2100 E
KG64B K302*AU2100 E
KG80 K302*AU2100 E
KG100 K302*AU2100 E
KG105 K302*AU2100 E
KG126 K302*AU2100 E
KG161 K302*AU2100 E
KG211 K302*AU2100 E
KG251 K302*AU2100 E
KG316 K302*AU2100 E

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 377


BLUE LINE switchgear
BLUE LINE switchgear

Padlockable Panel Mount, Enclosed Plastic or Stainless Steel – continued

Selection Data Switch Type KG125 KG160 KG210 KG250 KG315


IEC 60947, EN 60947, VDE 0660 KG10 KG20 KG32 KG41 KG64 KG126 KG161 KG211 KG251 KG316
KG80 KG100 KG105 KG127 KG162 KG212 KG252 KG317
IEC 204, EN 60204, VDE 0113 KG10B KG20B KG32B KG41B KG64B
Nominal
Ui V 690 690 690 690 690 690 690 690 1000¹ 1000¹ 1000¹ 1000¹ 1000¹
Voltage
Thermal
IU/Ith A 20 25 32 40 63 80 100 125 125 160 200 250 315
Current
Enclosed
thermal Ithe A 20 25 32 40 63 80 100 125 125 160 200 250 315
Current
Operational
Ie A 20 25 32 40 63 80 100 125 125 160 200 250 315
Current AC21A
Utilisation
Category 3 x 380V / kW 5.5 7.5 11 15 22 30 37 45 45 55 75 90 110
440V AC-23A/B

¹suitable for no load switching (AC-20A) above 690V.

Product Code No.


Panel Mount IP65 Panel Mount – Lockable 4 Pole ESC. (OFF-ON) V840G/D
Red / Yellow Padlock Handle - V840G/D
KG10B K400*AU2100 E
KG20B K400*AU2100 E
KG32B K400*AU2100 E
KG41B K400*AU2100 E
KG64B K400*AU2100 E
KG80 K400*AU2100 E
KG100 K400*AU2100 E
KG105 K400*AU2100 E
KG126 K400*AU2100 E
KG161 K400*AU2100 E
KG211 K400*AU2100 E
KG251 K400*AU2100 E
KG316 K400*AU2100 E
Plastic Enclosure IP65 Enclosed – Plastic 3 Pole +1 N/O 1 N/C Aux.
Red / Yellow Padlock Handle - V845
KG20A T203/AU1902 PFE1
KG32A T203/AU1902 PFE1
KG41 K302-PFE1 AUS0001
KG41 K302*AU0162*KL12
KG64 K302-PFE1 AUS0001
KG64 K302*AU0162*KL12
KG80 K302*AU0163*KL12
KG100 K302*AU0163*KL12
KG126 K302*AU0760*6FE
KG161 K302*AU0760*6FE
KG211 K302*AU0171*6FE
KG251 K302*AU0171*6FE
KG316 K302*AU0171*6FE

TM
KG Main Switches

Padlockable Panel Mount, Enclosed Plastic or Stainless Steel – continued

Selection Data Switch Type KG125 KG160 KG210 G250 KG315


IEC 60947, EN 60947, VDE 0660 KG10 KG20 KG32 KG41 KG64 KG126 KG161 KG211 KG251 KG316
KG80 KG100 KG105 KG127 KG162 KG212 KG252 KG317
IEC 204, EN 60204, VDE 0113 KG10B KG20B KG32B KG41B KG64B
Nominal Voltage Ui V 690 690 690 690 690 690 690 690 1000¹ 1000¹ 1000¹ 1000¹ 1000¹
Thermal Current IU/Ith A 20 25 32 40 63 80 100 125 125 160 200 250 315
Enclosed thermal
Ithe A 20 25 32 40 63 80 100 125 125 160 200 250 315
current
Operational Current
Ie A 20 25 32 40 63 80 100 125 125 160 200 250 315
AC21A
Utilisation Category 3 x
kW 5.5 7.5 11 15 22 30 37 45 45 55 75 90 110
380V / 440V AC-23A/B
¹suitable for no load switching (AC-20A) above 690V.

Product Code No.


Plastic Enclosure IP65 Enclosed - Plastic (larger enclosure) 3 Pole + 1 N/O 1 N/C Aux.
Red / Yellow Padlock Handle - V845 KG20B K302*AU0160*KL12
KG32B K302*AU0160*KL12
KG41B K302*AU0152*KL12
KG64B K302*AU0152*KL12
KG80 K302*AU0153*6FE
KG100 K302*AU0153*6FE
KG126 K302*AU0761*6FE
KG161 K302*AU0761*6FE
KG211 K302*AU0172*6AE metal
KG251 K302*AU0172*6AE metal
KG316 K302*AU0172*6AE metal
Enclosed – Plastic (1-0-2) 3 Pole C/O with centre OFF
KG20B K900*AU0157*KL12
KG32B K900*AU0157*KL12

BLUE LINE switchgear


KG41B K900*AU0158*KL12
KG64B K900*AU0158*KL12
KG80 K900*AU0159*6FE
KG100 K900*AU0159*6FE

11
BLUE LINE switchgear

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 379


BLUE LINE switchgear
BLUE LINE switchgear

Padlockable Panel Mount, Enclosed Plastic or Stainless Steel – continued

Selection Data Switch Type KG125 KG160 KG210 KG250 KG315


IEC 60947, EN 60947, VDE 0660 KG10 KG20 KG32 KG41 KG64 KG126 KG161 KG211 KG251 KG316
KG80 KG100 KG105 KG127 KG162 KG212 KG252 KG317
IEC 204, EN 60204, VDE 0113 KG10B KG20B KG32B KG41B KG64B
Nominal Voltage Ui V 690 690 690 690 690 690 690 690 1000¹ 1000¹ 1000¹ 1000¹ 1000¹
Thermal Current IU/Ith A 20 25 32 40 63 80 100 125 125 160 200 250 315
Enclosed thermal
Ithe A 20 25 32 40 63 80 100 125 125 160 200 250 315
current
Operational
Ie A 20 25 32 40 63 80 100 125 125 160 200 250 315
Current AC21A
Utilisation Category 3 x
kW 5.5 7.5 11 15 22 30 37 45 45 55 75 90 110
380V / 440V AC-23A/B
¹suitable for no load switching (AC-20A) above 690V.

Product Code No.


Stainless Steel Enclosure IP65 Enclosed – Stainless Steel 3 Pole + 1 N/O 1 N/C Aux. (Screwed lid)
KG20A K302*AUN0478*6SS0
KG32A K302*AUN0478*6SS0
KG41B K302*AUN0479*6SS1
KG64B K302*AUN0479*6SS1
KG80 K302*AUN0479*6SS1
KG100 K302*AUN0479*6SS1
KG125 K302*AUN0480*6SS2
KG161 K302*AUN0480*6SS2

Variations on request:-
Stop/Start Pushbuttons, Control & Changeover Switches.Selection of auxiliary contacts.

Product Code No.


Enclosed – Stainless Steel 3 Pole + 1 N/O 1 N/C Aux. (Hinged Door – Interlocked Door clutch)
Stainless Steel Enclosure IP65
with hinged door KG41B K302*AU1150*6SH1
KG64B K302*AU1150*6SH1
KG80 K302*AU1148*6SH1
KG100 K302*AU1148*6SH1
KG125 K302*AU1145*6SH2
KG161 K302*AU1145*6SH2
KG211 K302*AU1151*6SH3
KG251 K302*AU1151*6SH3
KG316 K302*AU1151*6SH3
Stainless Steel Enclosures…
Marine Grade 316 IP65
N/O contact late make early break
Finish:- Bead Blast or Food Industry.(FI)
Available on request:- Integrated Rain Hood. Hinged Door. Mounting Flanges, Stainless Steel
Padlock Device

TM
KG Main Switches

KG Main Switches –

Base mounted Padlockable with Extension Shafts

Selection Data Switch Type KG125 KG160 KG210 KG250 KG315


IEC 60947-3, EN 60947, VDE 0660 KG10 KG20 KG32 KG41 KG64 KG126 KG161 KG211 KG251 KG316
KG80 KG100 KG105 KG127 KG162 KG212 KG252 KG317
IEC 204, EN 60204, VDE 0113 KG10B KG20B KG32B KG41B KG64B
Nominal Voltage Ui V 690 690 690 690 690 690 690 690 1000¹ 1000¹ 1000¹ 1000¹ 1000¹
Thermal Current IU/Ith A 20 25 32 40 63 80 100 125 125 160 200 250 315
Enclosed thermal
Ithe A 20 25 32 40 63 80 100 125 125 160 200 250 315
current
Operational
Ie A 20 25 32 40 63 80 100 125 125 160 200 250 315
Current AC21A
Utilisation Category 3
kW 5.5 7.5 11 15 22 30 37 45 45 55 75 90 110
x 380V / 440V AC-23A/B

¹suitable for no load switching (AC-20A) above 690V.

Product Code No.


Base / DIN Mount. (KG10B ~ KG100) Door Clutch M280E/EF
Base mounted c/w P‘lockable Handle V840G/D
Door clutch (M280E) Esc. Plate OFF - ON
Padlock Device (V840G/D) 3 Pole
KG10B K300*AUN0481 VE
KG20B K300*AUN0481 VE
KG32B K300*AUN0481 VE
KG41B K300*AUN0481 VE
KG64B K300*AUN0481 VE
KG80 K300*AUN0481 VE
KG100 K300*AUN0481 VE
KG105 K300*AUN0481 VE

BLUE LINE switchgear


KG126 K300*AUN0481 VE
KG161 K300*AUN0481 VE
KG211 K300*AUN0481 VE
Door clutch M280E, padlock device V840GD KG251 K300*AUN0481 VE
KG316 K300*AUN0481 VE

Base mounted with Door Clutch


M280E & V845
Door Clutch

Esc. Plate
3 Pole
M280E/EF
P‘lockable Handle V840G/D
OFF - ON 11
KG10B K300*AUN0482 VE
BLUE LINE switchgear

KG20B K300*AUN0482 VE
KG32B K300*AUN0482 VE
KG41B K300*AUN0482 VE
KG64B K300*AUN0482 VE
KG80 K300*AUN0482 VE
KG100 K300*AUN0482 VE
KG105 K300*AUN0482 VE
KG126 K300*AUN0482 VE
KG161 K300*AUN0482 VE
KG211 K300*AUN0482 VE
KG251 K300*AUN0482 VE
KG316 K300*AUN0482 VE
Door clutch M280E, padlock device V845

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 381


BLUE LINE switchgear
BLUE LINE switchgear

KG Main Switches –

Base mounted Padlockable with Extension Shafts

Selection Data Switch Type KG125 KG160 KG210 KG250 KG315


IEC 60947-3, EN 60947, VDE 0660 KG10 KG20 KG32 KG41 KG64 KG126 KG161 KG211 KG251 KG316
KG80 KG100 KG105 KG127 KG162 KG212 KG252 KG317
IEC 204, EN 60204, VDE 0113 KG10B KG20B KG32B KG41B KG64B
Nominal Voltage Ui V 690 690 690 690 690 690 690 690 1000¹ 1000¹ 1000¹ 1000¹ 1000¹
Thermal Current IU/Ith A 20 25 32 40 63 80 100 125 125 160 200 250 315
Enclosed thermal
Ithe A 20 25 32 40 63 80 100 125 125 160 200 250 315
current
Operational
Ie A 20 25 32 40 63 80 100 125 125 160 200 250 315
Current AC21A
Utilisation Category 3 x
kW 5.5 7.5 11 15 22 30 37 45 45 55 75 90 110
380V / 440V AC-23A/B
¹suitable for no load switching (AC-20A) above 690V.

Product Code No.


Base / DIN Mount. (KG10B ~ KG100) Door Clutch M280E/EF
Base mounted c/w P‘lockable Handle V840G/D
Door clutch (M280E) Esc. plate OFF - ON
Padlock Device (V840G/D) 3 Pole + 1N/O 1 N/C aux.
(N/O aux. early break)
KG10B K302*AUN0483 VE
KG20B K302*AUN0483 VE
KG32B K302*AUN0483 VE
KG41B K302*AUN0483 VE
KG64B K302*AUN0483 VE
KG80 K302*AUN0483 VE
KG100 K302*AUN0483 VE
KG105 K302*AUN0483 VE
KG126 K302*AUN0483 VE
KG161 K302*AUN0483 VE
Door clutch M280E, padlock device V840GD KG211 K302*AUN0483 VE
KG251 K302*AUN0483 VE
KG316 K302*AUN0483 VE
Base mounted with Door Clutch Door Clutch M280E/EF
M280E & V845 P‘lockable Handle V840G/D
Esc. Plate OFF - ON
4 Pole
KG10B K400*AUN0481 VE
KG20B K400*AUN0481 VE
KG32B K400*AUN0481 VE
KG41B K400*AUN0481 VE
KG64B K400*AUN0481 VE
KG80 K400*AUN0481 VE
KG100 K400*AUN0481 VE
KG105 K400*AUN0481 VE
KG126 K400*AUN0481 VE
KG161 K400*AUN0481 VE
KG211 K400*AUN0481 VE
Door clutch M280E, padlock device V845 KG251 K400*AUN0481 VE
KG316 K400*AUN0481 VE

TM
KG Main Switches

KG Main Switches –

Base mounted Padlockable with Extension Shafts

Selection Data Switch Type KG125 KG160 KG210 KG250 KG315


IEC 60947-3, EN 60947, VDE 0660 KG10 KG20 KG32 KG41 KG64 KG126 KG161 KG211 KG251 KG316
KG80 KG100 KG105 KG127 KG162 KG212 KG252 KG317
IEC 204, EN 60204, VDE 0113 KG10B KG20B KG32B KG41B KG64B
Nominal Voltage Ui V 690 690 690 690 690 690 690 690 1000¹ 1000¹ 1000¹ 1000¹ 1000¹
Thermal Current IU/Ith A 20 25 32 40 63 80 100 125 125 160 200 250 315
Enclosed thermal
Ithe A 20 25 32 40 63 80 100 125 125 160 200 250 315
current
Operational Current
Ie A 20 25 32 40 63 80 100 125 125 160 200 250 315
AC21A
Utilisation Category 3 x
kW 5.5 7.5 11 15 22 30 37 45 45 55 75 90 110
380V / 440V AC-23A/B
¹suitable for no load switching (AC-20A) above 690V.

Product Code No.


3 Pole Change Over Panel Mounted with OFF
6 Pole Isolator Escutcheon 1/0FF/2
KG20B K900-620 E
Aux. Contacts fitted on request
KG32B K900-620 E
8 Pole Isolators and 4 Pole c/o also available
KG41B K900-620 E
KG64B K900-620 E
KG80 K900-620 E
KG100 K900-620 E
KG126 K900-620 E

BLUE LINE switchgear


KG161 K900-620 E
6 Pole Isolator Panel Mounted
Escutcheon plate OFF-ON
KG20B K600*AU2103 E
KG32B K600*AU2103 E
KG41B K600*AU2103 E
KG64B K600*AU2103 E
KG80 K600*AU2103 E
KG100 K600*AU2103 E
11
KG126 K600*AU2103 E
BLUE LINE switchgear

KG161 K600*AU2103 E
TERMINATION:
KG10 ~ KG125, KG160, KG210, KG250 & KG315 Tunnel.
KG126, KG161, KG211, KG251 & KG316 Lugs.
KG 127, KG 162, KG 212, KG 252 & KG317 Tunnel & Lugs.

COLTERLEC ™ ELEC TRIC AL ENGINEERING PRODUC T S | 383