Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Pag. 1
Pag. 2
CATALOGUE 2018
Draft Vers: 01
GENAQ Technologies SL.
Pol. Ind. Los Santos. Bulevar de los
Santos 34. 14900. Lucena . SPAIN
Pag. 3
CATALOGUE 2018
CONTENT
APPLICATIONS Pag 5
STRATUS 50 Pag 6
CUMULUS 50 Pag 14
Pag. 4
Drink pure water anywhere ...
Remote locations:
An affordable drinking water source with the best quality when the
cost of a connection to the water network involve a big investment.
Industrial Processes:
Pag. 5
STRATUS 50.
Features
Operation limits:
Technical features:
Pag. 6
Product Code:
GENAQ S50 XX - AC - 230 - I- 50
where: XX: Add options: IT, RF and/or OZ
AC standard / DC Optional
230-I-50: Specify:Voltage-Number of phases- Frequency
Production (l/day)
Temperature ºC
55 50 45 40 35 30 25 20 15 10
100 - - 67 64 61 55 45 34 22 13
90 - - 67 64 61 54 45 34 21 12
Relative Humidity (%)
80 - 71 66 63 59 52 43 32 20 12
70 71 69 64 60 54 47 37 25 17 10
60 67 64 59 52 46 39 28 20 12 5.4
50 60 57 50 43 37 28 21 14 6.7 2.6
40 47 43 37 29 24 19 14 7.0 2.9 0.9
30 29 27 23 18 15 11 5.7 2.6 0.9 0.5
20 16 15 12 7 5.2 2.9 1.5 0.5 - -
10 6.1 5.5 3.3 2.1 1.1 0.5 - - - -
Data measured with calibrated sensors in climate chamber at sea level with controlled T and RH.
Production is affected by factors such as height (-5.5% approx every 500m), filter cleaning, wind ...
Dimensions
Pag. 7
STRATUS 200.
Features
Operation limits:
Technical features:
Pag. 8
Product code:
GENAQ S200 - XX - AC - 230 - I- 50
Where: XX: Add options: IT, RF and /or OZ
AC standard / DC Optional
230-I-50: Specify: Voltage-Number of phases- Frequency
Production(l/day)
Temperature ºC
55 50 45 40 35 3025 20 15 10
100 - - 294 281 254 212 152 100 54 14
90 - - 294 280 253 210 150 98 53 14
Relative Humidity (%)
Dimensions
Pag. 9
NIMBUS 500.
Features
Operation limits:
Technical features:
Pag. 10
Product code: Inputs and outputs:
GENAQ N500 - XX - AC - 400 - III- 50 Inputs:
Where: XX: Add options:
IT, RF and/or CL Pluging Supplied plug 3F+N
AC: Always
400-III-50: Specify: Exterior tank level Dry contact NC.
Voltage-Number of phases- Frequency buoy signal
Outputs
Water connection Female 1/2”
Production(l/day)
Temperature ºC
55 50 45 40 35 30 25 20 15 10
100 - - 736 702 636 531 380 237 124 67
90 - - 735 701 632 526 375 233 122 66
Relative Humidity (%)
Dimensions
Pag. 11
NIMBUS N4500.
Features
Operation limits:
Technical features:
IOT option included, allowing remote mo- GENAQ N 4500-XX - 400 - III - 50
nitoring and maintenance diagnostics Where: XX: Add options:
PU o PR
400-III-50: Specify:
Voltage-Number of phases- Frequency
Pag. 12
Inputs and outputs:
Inputs: Outputs
Pluging Supplied plug 3F+N Water connection Female 1/2”
Production(l/day)
Temperature ºC
55 50 45 40 35 30 25 20 15 10
100 - - 6435 6187 5687 4828 3631 2270 1161 555
90 - - 6351 6102 5590 4737 3532 2207 1132 548
Relative Humidity (%)
Dimensions
Pag. 13
CUMULUS C 50.
Características
Operation limits:
Technical features:
Pag. 14
Product code: Inputs and outputs:
GENAQ C50 - XX - AC - 230 - I - 50 Inputs:
Where: XX: Add options:
IT, RF and/or CL Pluging Connect directly to board. Cable
AC: Elegir entre AC (st) y DC Gland M12
230-I-50: Specify Exterior tank level Dry contact NC
Voltage—Nº of phases*– Frecuency buoy signal
(*) Only for AC
Outputs
Water connection Female 1/2”
Production(l/day)
Temperature ºC
55 50 45 40 35 30 25 20 15 10
100 - - 67 64 61 55 45 34 22 13
90 - - 67 64 61 54 45 34 21 12
Relative Humidity (%)
80 - 71 66 63 59 52 43 32 20 12
70 71 69 64 60 54 47 37 25 17 10
60 67 64 59 52 46 39 28 20 12 5.4
50 60 57 50 43 37 28 21 14 6.7 2.6
40 47 43 37 29 24 19 14 7.0 2.9 0.9
30 29 27 23 18 15 11 5.7 2.6 0.9 0.5
20 16 15 12 7 5.2 2.9 1.5 0.5 - -
10 6.1 5.5 3.3 2.1 1.1 0.5 - - - -
Data measured with calibrated sensors in climate chamber at sea level with controlled T and RH.Production
is affected by factors such as height (-5.5% approx every 500m), filter cleaning, wind ...
…
Dimensions
Pag. 15
CUMULUS C500.
Features
Operation limits:
Technical features:
Pag. 16
Product code: Inputs and outputs:
GENAQ C500 - XX - AC - 400 - III - 50 Inputs:
where: XX: Add options:
Pluging Supplied plug 3F+N
IT, RF and/or CL
AC: Always
Exterior tank level Dry contact NC
400-III-50: Specify
buoy signal
Voltage-Number of phases- Fre-
quency Outputs
Water connection Female 1/2”
Production(l/day)
Temperature ºC
55 50 45 40 35 30 25 20 15 10
100 - - 846 803 754 700 639 473 248 134
90 - - 807 759 705 644 577 419 219 119
Relative Humidity (%)
Pag. 17
CUMULUS C5000.
Features
Operation limits:
Technical features:
Pag. 18
Inputs and outputs:
Product code:
GENAQ C 5000 - XX- 400 - III - 50 Inputs:
Where: XX: Add options:
PU and/or PR, CC and/or PC, PR, PW. Pluging Supplied plug 3F+N
400-III-50: Specify:
Exterior tank level Dry contact NC
Voltage-Number of phases- Frequency
buoy signal
Outputs
Water connection Female 1/2”
Production(l/day)
Temperature ºC
55 50 45 40 35 30 25 20 15 10
100 - - 7363 7080 6507 5525 4374 2734 1399 631
90 - - 7267 6983 6397 5420 4254 2659 1363 623
Relative Humidity (%)
Pag. 19
ANOTACIONES:
Pag. 20
ANOTACIONES:
Pag. 21
Pag. 22
CATALOGUE 2018
GENAQ Technologies SL
Pol. Industrial Los Santos. Bulevar de los Sntos 34
14900. Lucena Spain
www. genaq.com
Telephone: +34 957 62 57 12
Correo: info@genaq.com
Pag. 23