KEY FEATURE
• Variable sample frequency
• Over Load, Over Heat and Short Circuit Protections
• Loudspeaker Relay protection
• Serial communication interface
• Auxiliary supply output
• Balanced inputs
• LED indicators
• Dynamic clipping controller

DESCRIPTION
Available with three power sizes, 1000W, 1500W e 2000W, configurable as stereo, or bridge.
DA2000, is available also for 4 ohm or 8 ohm (stereo) or 8 ohm 16 ohm (bridge) to allow the load
capability required. The advanced technology adopted with variable sample frequency allows a
perfect dynamic uniformity at any sound level. The DA series amplifiers are the perfect choice for
any sound reinforcement application in medium power professional systems such as amplified
mixers, active loudspeakers, subwoofers and Line Array.

2
TECNHICAL SPECIFICATION
Model DA1000N DA1500 DA2000 DA2008
Continuous Power (stereo 4/8/16 Ω) (W) 500 / 250 / 125 750 / 375 / 188 - / 1000 / 500 1000 / 500 / 250
Continuous Power (bridge 8/16 Ω) (W) 1000 / 500 1500 / 750 - / 2000 2000 / 1000
Maximum output voltage (Vp) 64 78 127 90
Maximum output current (A) 22 28 22 33
Voltage Gain (dB stereo/bridge) 32 / 38 32 / 38 38 / 44 32 / 38
Frequency response 15Hz ÷ 25KHz ±3db
S/N Ratio > 110 dbA (20Hz ÷ 20KHz)
THD+N < 0,05 % (1W�÷ Max Power)
Input impedance 10KΩ
Input Sensibility (Vrms) 1,12 1,37 1,12 1,58
Max input (Vrms) 4,5
Damping Factor at 500Hz >500 >500 >150 >500
Power supply
Mains voltage (Vac) 230 ±15% - 115 ±15% (selectable)
Mains frequency (Hz) 50 / 60 ±10%
Rated Consumption (1/8 out power 230V) (A) 1,6 2,2 2,9 2,9
Rated Consumption (1/8 out power 115V) (A) 2,6 3,6 5,5 5,5
Connections
Aux supplies J12 (Vdc) ±75V / ±20 ±95V / ±20 ±148V / ±20 ±105V / ±20
Aux supplies J9 (Vdc) ±12-200mA / ±5-200mA (flat cable 26 poli)
Input J9 Balanced Inputs (flat cable 26 poles)
Indicators J9 2 LED bicolor (flat cable 26 poles)
Communication J9 RS232 (flat cable 26 poles)
Mute
Protections
Output overload protection Electronic
Output short circuit protection Electronic
Over heat protection Electronic
Output DC protection Electronic/Relay
Mains line protection Fuse
Antipike of Mains 480 Joules, 2ms
Clipping protection Electronic with signal compression
General Data
Fan noise (dBA@1mt) < 40
Ambient Temperature (°C) 0 ÷ 40
Relative Humidity (%) < 95 (no condensation)
Dimension (w x d x h) mm 124 x 218 x 72
Weight (kg) 1,28 1,34 1,34 1,37

3
DA1000N Measures

4
DA1500 Measures

5
DA2000, DA2000/8 Measures

6
INPUT CONNECTIONS

OUTPUT CONNECTIONS

7
MAINS CONNECTIONS

NOTE:
J16-J18 open for 230V operation
J16-J18 short for 115V operation

8
AUXILIARY SUPPLIES CONNECTOR

9
PCB LAYOUT

10
PROTECTIONS
1. Over/Under Vmains: switches off of the SMPS supply circuit in case of excessive high or low
voltage input detections, re‐starting automatically when the normal conditions are restored.
2. Short circuit: disconnects the load if over current is detected, re‐connecting automatically
when the normal conditions are restored.
3. Relay: DC protections on outputs with start delay at the switch on and anticipate
disconnection at the switch off.
4. Soft Clip with dynamic control: with a musical signal the limiter allows the first peaks to pass
thru unaltered. In case the peaks shall persist, the limiter acts to reduce the signal avoiding
clipping distortion.
5. Temperature sensor on the heat‐sink
36°C: fan activation;
58°C: start a progressive slow input signal attenuation till a maximum of ‐20dB;
60°C: the amp module switch off.
When the normal temperature conditions are restored, the module switches on again.
6. Temperature sensor on the transformer
60°C: fan activation;
70°C: start a progressive slow input signal attenuation till a maximum of ‐20dB;
90°C: the module switch off.
When the normal temperature conditions are restored, the module switches on again.
7. Monitoring of the averaged output power: if a high level input signal persists for an extended
period of time and consequently the averaged output power exceeds the normal operation,
the module introduce a progressive slow input signal attenuation till a maximum of ‐20dB.