Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
00
6.00
CO
LAV FD FD UR 150MMØ PVC
SOIL PIPE
UR
LAV
100 MMØ FD
PVC PIPE CO WC WC
UR UR UR UR UR
CO
100MMØ WC WC WC WC WC WC
PVC PIPE
CO
6.00
6.00
FD FD
24.00
CO
50 MMØ PVC PIPE LAV
3.00
FD
75 MMØ PVC PIPE UR
150MMØ PVC
50 MMØ PVC AIRVENT PIPE WC SOIL PIPE
CO LAV
6.00
CO CO 75 MMØ
150MMØ PVC SOIL UR PVC PIPE
WASTE STACK PIPE 150 MMØ LAV FD
3.00
PVC PIPE FD UR
CO
150 MMØ
75MMØ PVC PIPE
PVC PIPE CO 4
3
75 MMØ 2
6.00
CO
LAV 75 MMØ
WC PVC PIPE
FD
WC
FD FD
WC KS
UR UR WC
CO
150MMØ PVC
SOIL PIPE
3.00
3.00
SEPTIC
TANK
4
3
2
1
150MMØ PVC
OUTLET PIPE
TO MAIN
SEWER LINE
PEDESTRIAN LANE
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
0.90
0.90
CO
SS
CO
WC WC WC WC WC WC CO
WC
FD
FD UR
CO
LAV 75MMØ PVC PIPE UR
6.00
6.00
CO FD FD FD
LAV UR
150MMØ PVC
UR SOIL PIPE
LAV
100 MMØ FD
PVC PIPE CO WC WC
UR UR UR UR UR
CO
100MMØ WC WC WC WC WC WC
PVC PIPE
FD FD
CO
6.00
6.00
CO LAV LAV LAV SS 150MMØ PVC SOIL
WASTE STACK PIPE
50 MMØ CO 75 MMØ PVC VENT PIPE CO
PVC PIPE 75 MMØ PVC VENT PIPE
FD 50 MMØ
LAV
24.00
24.00
PVC PIPE
50 MMØ CO
UR LAV
PVC PIPE WC
FD
FD
3.00
PVC PIPE
100 MMØ WC FD
UR
WC WC WC CO
WC UR
6.00
150 MMØ
PVC PIPE
3.00
6.00
6.00
PERIMETER LINE
SECOND FLOOR PLAN
1 SANITARY LAYOUT PLAN
P-2 SCALE 1:100 MTS
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
6.00
CO FD FD FD
LAV UR
150MMØ PVC
UR SOIL PIPE
LAV
100 MMØ FD
PVC PIPE CO WC WC
UR UR UR UR UR
CO
100MMØ WC WC WC WC WC WC
PVC PIPE
FD FD
CO
6.00
6.00
CO LAV LAV LAV SS 150MMØ PVC SOIL
WASTE STACK PIPE
75 MMØ PVC VENT PIPE CO
75 MMØ PVC VENT PIPE
24.00
24.00
3.00
6.00
3.00
6.00
6.00
W2 W1
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
.15 2.40 .15 1.50 .15 1.50 .15 ALL VERT SOIL & WASTE STACK PIPE SHALL BE EXTEND FULL SIZE ABOVE ROOF LINE
TO SEPTIC VAULT
.10
0.50 AS VENTS EXCEPT OTHERWISE SPECIFICALLY INDICATED
INLET PIPE 0.40
.05 .05 ALL CHANGES IN PIPE SIZES ON SOIL WASTE LINE SHALL BE MADE W THE REDUCING
.50 M.
.30
6" CHB FITTINGS OR RECESS REDUCERS
4" CHB
PROVIDE CLEANOUT FOR EVERY FIFTEEN METERS ( 15.00 M ) DISTANCE
SEWER LINE HORIZONTAL LINE
(OUTLET PIPE)
.10
.15
PROVIDE 50MM Ø P-TRAP FOR EVERY 100M M Ø X 100MM Ø FLR DRAIN
P L A N
1.10
PROVIDE STOP-COCK FOR EVERY FIXTURES
INSIDE WIDTH
3.00 METERS
R.C. COVER W STL
2.70M
12MMØ BARS LIFTING COVER
0.50
SPACED @ .20M LEGEND & SYMBOLS
O.C BW
COLD WATER LINE
.40 X .40 SHO SHOWER FD FLOOR DRAIN
1.10
MANHOLE PLASTERED FIN. PVC POLYVINYL CHLORIDE UR URINAL
DRAIN LINE SV SEPTIC VAULT
STORM DRAINAGE DS DOWNSPOUT GV GATE VALVE
.15
PIPE LINE 10 MM THK CB CATCH BASIN
CHB WALL W SD SHOWER DRAIN CV CHECK VALVE
10 MMØ BARS
UR URINAL
120mm
P L A N VSTR VENT STACK THRU ROOF SOIL PIPE LINE
4-12 MMØ
WC WATER CLOSET
TO SEPTIC VAULT
.15
FHC GV
.30
WATER LEVEL
WATER LEVEL
0.05
0.05
GV GV
BRANCH PIPE ROOF DECK LEVEL
1.75
WF1
.40M
NOTE: SECTION
FHC
VERIFY SIZE OF SEPTIC TANK TO LOCATION
AT LEAST 2.00 MTRS. APART FROM THE BUILDING LINE
TO MAIN WATER SOURCE GV CV BRANCH PIPE GROUND FLOOR LEVEL
MAYNILAD GV WM CV
FROM MAIN WATER SOURCE
MAYNILAD
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
SS WC WC WC WC WC WC WC GV0.90
6.00
LAV UR
GV
WC WC WC WC WC WC
6.00
32MMØ PPR CWL LAV LAV LAV SS
RISER PIPE
GV
32MMØ PPR CWL
RISER PIPE
24.00
24.00
0.90 20MMØ PPR CWL
LAV GV
3.00
UR
6.00
LAV
LAV UR
20MMØ PPR CWL
3.00
UR
EDSA
4
3
2
20MMØ PPR CWL LAV 1
RISER PIPE
6.00
6.00
LAV WC
20MMØ PPR CWL
WC RISER PIPE
UR WC WC KS
GV GV
GV 32MM Ø PPR CWL PIPE
3.00
3.00
CV
WM M
4
3 GV
2
1
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
0.90
0.90
GV
SS WC WC WC WC WC WC WC 25MM Ø PPR CWL PIPE
6.00
UR
LAV UR
LAV UR
25MM Ø PPR CWL PIPE
UR UR UR UR UR WC WC GV
WC WC WC WC WC WC
25MM Ø PPR CWL PIPE
6.00
6.00
25MM Ø PPR CWL PIPE
32MMØ PPR CWL LAV LAV LAV SS
RISER PIPE
GV
32MMØ PPR CWL 32MMØ PPR CWL
LAV
RISER PIPE
24.00
24.00
20MM Ø PPR PIPE
GV
WC UR LAV
3.00
UR
WC
GV UR
WC WC WC WC
UR
6.00
GV
3.00
6.00
6.00
PERIMETER LINE
SECOND FLOOR PLAN
1 WATERLINE LAYOUT PLAN
P-6 SCALE 1:100 MTS
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
GV
WATER SS WC WC WC WC WC WC WC
TANK
GV UR
LAV
6.00
6.00
UR
LAV UR
LAV UR
UR UR UR UR UR WC WC GV
GV
WC WC WC WC WC WC
6.00
32MM Ø PPR CWL PIPE
24.00
3.00
6.00
3.00
6.00
6.00
W2 W1
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
300MMØ PVC
STORM DRAIN 300MM Ø PVC STORM DRAIN PIPE
PIPE TO MAIN CB CB CB CB CB CB CB CB CB CB
SEWER LINE
0.90
6.00
6.00
200MM Ø PVC STORM DRAIN PIPE
6.00
6.00
24.00
24.00
0.90 CB
3.00
6.00
3.00
EDSA
CB
4
3
2
1
6.00
6.00
3.00
3.00
4
3
2
1
PEDESTRIAN LANE
GROUND FLOOR PLAN
1 STORM DRAIN LAYOUT PLAN
P-8 SCALE 1:100 MTS
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
150MM Ø PVC
DOWNSPOUT PIPE
0.90
0.90
DS DS DS DS DS DS DS DS DS DS
6.00
6.00
6.00
6.00
24.00
24.00
DS
3.00
DOWNSPOUT PIPE
100MM Ø PVC
6.00
3.00
DS
6.00
6.00
SECOND FLOOR PLAN
1 STORM DRAIN LAYOUT PLAN
P-9 SCALE 1:100 MTS
PERIMETER LINE
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
RD RD RD RD RD RD RD RD RD RD
1
6.00
2
6.00
24.00
3
6.00
5
6.00
6
3.00
ROOF PLAN
1 STORM DRAIN LAYOUT PLAN
P-10 SCALE 1:100 MTS
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
DS DS DS DS DS DS ACU DS DS DS
ACU ACU ACU ACU ACU ACU ACU ACU ACU ACU ACU
ACU ACU ACU ACU ACU NBI STO
MULTI PURPOSE RM
LANDBANK DI AND NBI DI STO
STO
6.00
MALE CR
STORAGE RM
ACU ACU
CABINET
CABINET
EXAMINATION RM - 2 ACU
TRANSACTION WINDOWS
ACU
H A L L W A Y
ACU ACU CLIENTS LOUNGE CLIENTS LOUNGE ACU
NP SECTION
RECEPTION AREA
6.00
OFFICE FEMALE CR
ACU ACU
INTERVIEW RM INTERVIEW RM
CHIEF
PANEL LANDBANK
INTERVIEW DI & NBI CLEARANCE
CHASE
PIPE
24.00
LOCKER COUNTER TABLE COUNTER TABLE STORAGE
RM EXIT ACU
H A L L W A Y
H A L L W A Y
UP
ACU ACU
WASH
6.00
CR
AREA ELECTRICAL RM
EXIT
FEMALE MALE
CR
ACU
CR
32.70
COMPUTER TABLE
CLIENTS LOUNGE
SERVER
CCTV RM
6.00
ACU EXAM RM STORAGE UP
ACU
MALE FEMALE
PWD CR
EXIT LOBBY UP
URINE COLLECTION CHIEF
STO
RAMP UP
ENTRANCE
TRANSFORMATION
ENTRANCE FROM
MAIN ENTRY
OVAL
PORCH
GROUND FLOOR PLAN
1 ACU DRAIN LAYOUT PLAN 4
3
2
1
RAMP UP
CANOPY LINE
P E D E S T R I A N L A N E
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
0.90
0.90
DS DS DS DS ACU DS DSACU DS DS ACU ACU DS DS
ACU ACU
6.00
6.00
ACU
ACU
ACU
ACU
ACU
6.00
6.00
ACU
24.00
24.00
ACU ACU ACU
3.00
ACU
6.00
ACU ACU
3.00
ACU
ACU
ACU
ACU ACU
ACU
6.00
6.00
ACU
ACU
ACU
ACU
PERIMETER LINE
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
0.90
6.00
6.00
6.00
6.00
24.00
24.00
0.90
3.00
6.00
3.00
EDSA
FHC
100MM Ø GI PIPE 4
DRY STAND PIPE 3
2
1
6.00
6.00
FHC
100MM Ø GI PIPE
3.00
3.00
DRY STAND PIPE
PEDESTRIAN LANE
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
0.90
0.90
6.00
6.00
6.00
6.00
24.00
24.00
3.00
6.00
3.00
FHC
100MM Ø GI PIPE
DRY STAND PIPE
6.00
6.00
FHC
100MM Ø GI PIPE
DRY STAND PIPE
PERIMETER LINE
PROJECT TITLE: PREPARED BY: CHECKED BY: SUBMITTED BY: RECOMMEND APPROVAL: APPROVED BY: SHEET NO.
6.00 6.00 6.00 6.00 6.00 6.00 6.00 6.00 6.00 6.00
6.00
6.00
6.00
24.00
24.00
3.00
6.00
3.00
FHC
100MM Ø GI PIPE
DRY STAND PIPE
6.00
6.00
FHC
W2 W1
100MM Ø GI PIPE
DRY STAND PIPE