Okotherm CIC Fire Resistant Cable R
Type TC Cable
Multiple Tinned or Nickel Coated Copper Conductors 90°C Dry Rating
=
202-17-3452 14 (7X) 2 45 0.48 0.18 124 147 15 15
202-17-3453 14 (7X) 3 45 0.51 0.20 142 165 15 15
45
202-17-3454 14 (7X) 4 60 0.59 0.27 202 226 15 15
202-17-3455 14 (7X) 5 60 0.64 0.32 238 277 15 15
202-17-3457 14 (7X) 7 60 0.70 0.39 297 336 15 14
202-17-3459 14 (7X) 9 60 0.81 0.52 345 384 15 14
202-17-3462 14 (7X) 12 45 80 0.95 0.71 497 561 12 10
202-17-3469 14 (7X) 19 80 1.10 0.95 696 776 12 10
202-17-3487 14 (7X) 37 80 1.46 1.67 1256 1399 10 8
202-17-3552 12 (7X) 2 45 0.52 0.21 154 177 20 20
202-17-3553 12 (7X) 3 60 0.59 0.27 205 229 20 20
45
202-17-3554 12 (7X) 4 60 0.64 0.32 254 293 20 20
202-17-3555 12 (7X) 5 60 0.69 0.37 301 340 20 20
202-17-3557 12 (7X) 7 60 0.75 0.44 380 419 20 17
202-17-3559 12 (7X) 9 80 0.92 0.67 479 543 20 17
202-17-3562 12 (7X) 12 45 80 1.03 0.83 636 716 15 12
202-17-3569 12 (7X) 19 80 1.20 1.13 905 985 15 12
202-17-3587 12 (7X) 37 80 1.60 2.01 1655 1798 12 10
202-17-3652 10 (7X) 2 60 0.60 0.28 211 235 30 30
202-17-3653 10 (7X) 3 60 0.63 0.31 261 300 30 30
10 (7X) 4 45 60 0.69 0.37 327 366 30 28
202-17-3654
202-17-3655 10 (7X) 5 60 0.75 0.44 389 428 30 28
202-17-3657 10 (7X) 7 60 0.82 0.53 499 563 28 24
202-17-3659 10 (7X) 9 45 80 1.00 0.69 627 691 28 24
202-17-3662 10 (7X) 12 80 1.12 0.99 836 916 28 17
Visit Okonite's web site, www.okonite.com, for the most up to date dimensions.
Okotherm CIC Fire Resistant Cable
Type TC Cable
600V Power & Control Tray Cable
=
202-16-3403 14 (7X) 14 0.58 0.26 206 230 15 15
202-16-3503 12 (7X) 3 45 12 60 0.62 0.30 254 278 20 20
202-16-3603 10 (7X) 10 0.66 0.34 322 361 30 30
112-16-3503 8 (133X) 10 60 0.78 0.48 447 486 55 50
112-16-3603 6 (133X) 3 60 8 80 0.89 0.62 625 689 75 65
112-16-3703 4 (133X) 8 80 0.97 0.74 783 847 95 85
Visit Okonite's web site, www.okonite.com, for the most up to date dimensions.
= area for calculation of cable tray fill in The ampacities shown apply to open runs of cable, installation
accordance with NEC Section 392.22. in any approved raceway, direct burial in the earth, or as aerial
cable on a messenger. Derating for more than three current
(1) are based on Table 310.15(B)(16) of the National carrying conductors within the cable is in accordance with
Electrical Code for conductors rated 90°C, in a multi-conductor NEC Section 310.15(B)(3)(a).
cable, at an ambient temperature of 30°C (86°F). The 75°C
column is provided for additional information. The ampacities shown also apply to cables installed in cable
tray in accordance with NEC Section 392.80.
THE OKONITE COMPANY
C/12110413 Ramsey, New Jersey 07446