Sei sulla pagina 1di 2

Nodes For The Master State Control (MSC): State description for FLG

Node Nr. Description


1 Start node; first node after MCE activation
2 Vehicle Bus Monitor; the communication to all processors is monitored
10 Release process to processor SLG1 & SLG2
12 MCE starts 'Switch off timer'
13 MCE switches off
70 Disturbance with or without VCB off (Priority 1 fault)
71 FLG ready for acknowledge; Protective action executed
110 Test periphery SLG1
120 Test periphery SLG2
310 Release Test 1 ALG1
320 Release Test 1 ALG2
350 Release Test 2 ALG1
351 Release Test 2 ALG2
390 ALG ready
503 Loco ready for setup, cab not active
504 Cab active, Key switch in Pos."D" (Multiple operation: Cab on slave loco active)
550 Pantograph up enable
560 VCB enable
570 VCB closed
580 Gate Unit Bogie 1 enable
581 Gate Unit Bogie 2 enable
583 DC-Link precharging
584 Release converter contactor bogie 1
585 Release converter contactor bogie 2
590 DC-Link ready
592 Configuration Harmonic Filter (true only if filter is on)
594 NSC &
NSC pulsing (true only
ASC pulsing, if theremotors
Traction is no traction interlock
magnetised, B1/B2)
TE/BE effort enable (true only if
596 there is no traction interlock B1/B2)
600 VCB off , Panto Down
601 Shut Down Loco , DC link deenergising
605 DC - Link voltage too low. prepare precharging
612 MCE starts 'switch off timer'
613 MCE switches off
700 Disturbance without VCB off
701 Loco ready again
710 Disturbance with VCB off
715 Loco Ready for VCB on
716 Protective shut-down activated through SLG1/2

MSC Disturbances / Nodes Next node


present Disturbance sequence
002-390 disturbance without VCB off 070 / 071
002-390 disturbance with VCB off 070 / 071
503-596
503-596, disturbance without VCB off 700
710 // 701
715
700-701 disturbance
disturbance with
with VCB
VCB off
off only if SLG /710
716/ 715
600-612 commands protective turn off / 716

Potrebbero piacerti anche