PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
Measuing instruments for pressure DS III series

Fig. 1/20 SITRANS P transmitters, DS III series for pressure, absolute pressure, differential pressure, flow and level, with visible digital display

■ Application ■ Elements for parameterization of transmitter


Various versions of the SITRANS P transmitter, DS III series, are
Parameterization using Input keys HART
available with a two-wire circuit. The output signal is a load-inde- communication
pendent direct current of 4 to 20 mA linearly proportional to the
input pressure. Start-of-scale value 4 4
Full-scale value 4 4
Transmitters conforming to the type of protection "Intrinsic
Electric damping 4 4
safety" and "Explosion-proof" may be installed within potentially
explosive atmospheres (zone 1) or zone 0. The transmitters are Start-of-scale value without applica- 4 4
provided with an EU prototype test certificate and comply with tion of a pressure ("Blind setting")
the corresponding harmonized European standards of the Full-scale value without application of 4 4
ATEX. a pressure ("Blind setting")
Zero adjustment (correction of position) 4 4
Transmitters with the type of protection "Intrinsic safety" for use
at zone 0 may be operated with power supply units of category Current transmitter 4 4
"ia" and "ib". Fault current 4 4
Disabling of keys, write protection 4 4 1)
The transmitters can be equipped with various designs of
remote seals for special applications such as the measurement Type of dimension and actual dimen- 4 41
of highly viscous substances. sion
Characteristic (linear, square-rooted) 4 2) 4 2)
The transmitters can be programmed locally using three input
Input of characteristic 4
keys or externally via HART. The following table describes the
fundamental parameters. Further parameters for special appli- Freely-programmable LCD 4
cations are accessible via HART. Diagnostics 4
• Event counter
• Slave pointer
• Maintenance timer
■ Physical dimensions available for the display • Simulation functions
• Display of zero correction
• Limit transmitter
Dimension group Physical dimension • Saturation alarm
Pressure Pa, MPa, kPa, hPa, bar, mbar, torr, atm, 1 4 Possible
) Cancel apart from write protection
(setting can also be made in psi, g/cm2, kg/cm2, inH2O, inH2O (4 °C),
2) Only differential pressure
the factory) mmH2O, ftH2O, inHg, mmHg
Level (height data) m, cm, mm, ft, in
Volume m3, dm3, hl, in3, ft3, yd3, US gallon, Imp.
gallon, bushel, barrel, barrel liquid
Volume flow m3/s, m3/h, m3/d, l/s, l/min, ft3/s, ft3/min,
ft3/d, US gallon/s, US gallon/min
Mass flow g/s, g/min, g/h, g/d, kg/s, kg/min, kg/h,
kg/d, t/min, t/h, t/d, lb/s, lb/min, lb/h, lb/d,
STon/min, STon/h, STon/d, LTon/h, LTon/d
Total mass flow kg, g, t, oz, lb, STon, LTon
Temperature K, °C, °F, °R
Miscellaneous %, mA

icenta Controls Ltd SITRANS P Pressure Transmitters – page 1 of 20

Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

■ Transmitter for pressure ■ Transmitter for differential pressure and flow


This type of transmitter measures the pressure of corrosive and This type of transmitter is used to measure
1
non-corrosive gases, vapors and liquids. Spans are possible • the differential pressure
from 0.01 to 400 bar (0.145 to 5802 psi).
• a small positive or negative pressure
■ Maximum working pressure for pressure transmitters • the flow q ~
sure device)
'p (together with a primary differential pres-

Span Maximum working pressure Spans are possible from 1 mbar to 30 bar (0.0145 to 435 psi).
0.01 to 1 bar (0.15 to 14.5 psi) 6 bar (87 psi)
0.04 to 4 bar (0.58 to 58 psi) 10 bar (145 psi) ■ Maximum working pressure for differential pressure and
0.16 t 16 bar (2.32 to 232 psi) 32 bar (464 psi) flow transmitters
0.6 to 63 bar (9.1 to 914 psi) 100 bar (1450 psi)
1.6 to 160 bar (23.2 to 2320 psi) 250 bar (3626 psi) Span Maximum working pressure
(nominal pressure)
4.0 to 400 bar (58.0 to 5802 psi) 500 bar (7252 psi)
PN (MWP) PN (MWP)
(7MF4433) (7MF4533)
■ Transmitter for absolute pressure 1.0 to 20 mbar 32 bar (464 psi) -
(0.0145 to 0.29 psi)
This type of transmitter measures the absolute pressure of cor-
rosive and non-corrosive gases, vapors and liquids. 1.0 to 60 mbar 160 bar (2320 psi) -
(0.0145 to 0.87 psi)
Two series are available: 2.5 to 250 mbar 160 bar (2320 psi) 420 bar (6092 psi)
• "Pressure" series (0.036 to 3.63 psi)
• "Differential pressure" series 6.0 to 600 mbar 160 bar (2320 psi) 420 bar (6092 psi)
(0.087 to 8.7 psi)
The "Differential pressure" series has a higher pressure limit for 16.0 to 1,600 mbar 160 bar (2320 psi) 420 bar (6092 psi)
the medium. (0.23 to 23.3 psi)
Spans are possible from 8.3 mbar to 160 bar (0.12 to 2320 psi). 50.0 to 5,000 mbar 160 bar (2320 psi) 420 bar (6092 psi)
(0.73 to 72.5 psi)
■ Maximum working pressure for absolute pressure 300.0 to 30,000 mbar
(4.35 to 435 psi)
160 bar (2320 psi) 420 bar (6092 psi)
transmitters from the "Pressure" series (7MF4233)
Span Maximum working
pressure
■ Transmitter for level
8.3 to 250 mbar (0.12 to 3.6 psi) 6 bar (87 psi) This type of transmitter with mounting flange measures the level
43.0 to 1,300 mbar (0.62 to 18.9 psi) 10 bar (145 psi) of corrosive and non-corrosive liquids in open or closed contain-
ers. Spans are possible between 25 mbar (0.36 psi) and 5 bar
160.0 to 5,000 mbar (2.32 to 72.5 psi) 30 bar (435 psi) (72.5 psi). The nominal mounting flange diameter is DN 80 or
1,000.0 to 30,000 mbar (14.5 to 435 psi) 100 bar (1450 psi) DN 100 (3 or 4 inch).

■ Maximum working pressure for absolute pressure transmit- In the case of level measurements in open containers, the low-
pressure connection of the measuring cell remains open (mea-
ters from the "Differential pressure" series (7MF4333) surement with respect to atmosphere), while for measurements
s

in closed containers, this connection must be connected to the


Span Maximum working
pressure container in order to compensate the static pressure.
8.3 to 250 mbar (0.12 to 3.6 psi) 32 bar (464 psi) The wetted parts are constructed from a variety of materials
43 to 1,300 mbar (0.62 to 18.9 psi) 32 bar (464 psi) depending on the degree of corrosion resistance required.
160 to 5,000 mbar (2.32 to 72.5 psi) 32 bar (464 psi)
1,000 to 30,000 mbar (14.5 to 435 psi) 160 bar (2320 psi) ■ Maximum working pressure for level transmitters
5,300 to 100,000 mbar (76.9 to 1450 psi) 160 bar (2320 psi)
Span Maximum working pressure
with M10 and 7/16-20 (nominal pressure)
UNF thread in the pro-
cess flanges 25 to 250 mbar See mounting flange on page 1/39
(0.36 to 3.63 psi)
25 to 600 mbar See mounting flange on page 1/39
(0.36 to 8.7 psi)
53 to 1,600 mbar See mounting flange on page 1/39
(0.77 to 23.2 psi)
160 to 5,000 mbar See mounting flange on page 1/39
(2.32 to 72.5 psi)

icenta Controls Ltd SITRANS P Pressure Transmitters – page 2 of 20

Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
Siemens FI 01 · February 2004 1/21
PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

■ Design and mode of operation ■ Mode of operation


1 The SITRANS P transmitter, DS III series, is immediately ready Mode of operation of the electronics
for operation following installation. The adjustable span corre-
sponds to the data on the rating plate. If a customer-specific set- The input variable is converted by the sensor (1, Fig. 1/22) into
ting is made in the factory, the start-of-scale and full-scale an electric signal which is amplified by the instrument amplifier
values are printed on the rating plate. (2) and digitized in an analog-to-digital converter (3). The digital
information is evaluated in a microcontroller, its linearity and
If necessary, the parameters can also be changed during com- temperature response corrected, and converted in a digital-to-
missioning using simple input operations on the transmitter. analog converter (5) into the output current of 4 to 20 mA. A
diode circuit (10) protects against incorrect polarity. The data
■ Design specific to the measuring cell, the electronics data, and the
parameter data are stored in two non-volatile memories (6). The
The transmitter consists of various components depending on first memory is coupled to the measuring cell, the second to the
the customer-specific order. The possible versions are listed in electronics. Replacement of the electronics and/or the measur-
the ordering information. ing cell is therefore possible (modular design).
The rating plate (3, Fig. 1/21) with the Order No. is located on the
side of the housing. The specified number together with the The three input keys (8) can be used to directly parameterize
ordering information provide details on the optional design the transmitter at the position of measurement, and also to view
details and on the possible measuring range (physical proper- results, error messages and operating modes on the digital
ties of built-in sensor element). display (9). The HART modem (7) permits parameterization
The approval label is located on the opposite side. using a protocol according to the HART specification.
The housing is made of die-cast aluminium or stainless steel pre-
cision casting. A round cover is screwed on at the front and rear.
The front cover (6) can be fitted with a viewing pane so that the 9
measured values can be read directly on the digital display. The 8
0 0 00 0
inlet (4) to the electrical junction box is located either on the left M 00
or right side. The unused opening in each case is sealed by a
blanking plug. The protective earth connection is located on the 10
rear of the housing. 2 3 4 5

The electrical junction box for the power supply and screen is mC IA, UH
accessible by unscrewing the rear cover. The bottom part of the
housing contains the measuring cell with process connection 7
(1). This is protected from rotating by a locking screw (8). The
HART interface
modular design of the SITRANS P, DS III series, means that the
measuring cell and electronics can be replaced if necessary.
The set parameter data are retained. EEPROM
6
At the top of the housing is a plastic cover (5). The input keys are
Electronics
located underneath this cover.
1 6
EEPROM

Sensor

Pe
Measuring cell

1 Measuring cell sensor


2 Instrument amplifier
3 Analog-to-digital converter
4 Microcontroller
5 Digital-to-analog converter
6 One non-volatile memory each in the measuring cell and electronics
7 HART interface
8 Three input keys (local operation)
9 Digital display
10 Diode circuit and connection for external ammeter
IA Output current
UH Power supply
Pe Input variable

Fig. 1/22 SITRANS P transmitter, DS III series, electronics

Fig. 1/21 SITRANS P transmitter for pressure, DS III series, front view

icenta Controls Ltd SITRANS P Pressure Transmitters – page 3 of 20

Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
1/22Siemens FI 01 · February 2004
PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series
SITRANS P transmitter, DS III series, for pressure SITRANS P transmitter, DS III series, for absolute pressure,
The pressure pe is applied via the process connection
(2, Fig. 1/23) to the measuring cell (1). It is transmitted further via
from the differential pressure series
The absolute pressure is transmitted via the seal diaphragm (6,
1
the seal diaphragm (3) and the filling liquid (4) to the silicon pres- Fig. 1/25) and the filling liquid (8) to the silicon pressure sensor
sure sensor (5) whose measuring diaphragm is then flexed. The (3). If the measuring limits are exceeded, the overload dia-
resistance of four piezo-resistors fitted in the diaphragm in a phragm (2) is flexed until the seal diaphragm rests on the body
bridge circuit thus changes. This change in resistance results in of the measuring cell (7), thus protecting the silicon pressure
a bridge output voltage proportional to the input pressure. sensor from overloads. The difference in pressure between the
The pressure transmitters with spans d63bar (d914 psi) mea- input pressure (pe) and the reference vacuum (1) on the low-
sure the input pressure compared to atmospheric, transmitters pressure side of the measuring cell flexes the measuring dia-
with spans t 160 (t 2320 psi) compared to a vacuum. phragm. The resistance of four piezo-resistors fitted in the dia-
phragm in a bridge circuit thus changes. This change in
resistance results in a bridge output voltage proportional to the
absolute pressure.

5 2 3 4 1 Reference vacuum
4 2 Overload diaphragm
3 3 Silicon pressure sensor
1 1 Measuring cell 4 O-ring
2 Process connection 5 5 Process flange
3 Seal diaphragm 6 Seal diaphragm
1 Pe
4 Filling liquid 7 Body of measuring cell
5 Silicon pressure sensor 6 8 Filling liquid
Pe Pressure as input variable Pe Absolute pressure as
input variable
2
8 7
p
e

Fig. 1/23 Measuring cell for pressure, functional diagram Fig. 1/25 Measuring cell for absolute pressure from differential pressure
series, functional diagram

SITRANS P transmitter, DS III series, for absolute pressure, SITRANS P transmitter, DS III series, for differential pressure
from the pressure series and flow
The absolute pressure is transmitted via the seal diaphragm (3, The differential pressure is transmitted via the seal diagrams (1,
Fig. 1/24) and the filling liquid (4) to the silicon absolute pressure Fig. 1/26) and the filling liquid (7) to the silicon pressure sensor
sensor (5) whose measuring diaphragm is then flexed. The re- (4). If the measuring limits are exceeded, the overload dia-
sistance of four piezo-resistors fitted in the diaphragm in a phragm (3) is flexed until one of the seal diagrams rests on the
bridge circuit thus changes. This change in resistance results in body of the measuring cell (6), thus protecting the silicon pres-
a bridge output voltage proportional to the absolute pressure. sure sensor from overloads. The measuring diaphragm is flexed
by the applied differential pressure. The resistance of four piezo-
resistors fitted in the diaphragm in a bridge circuit thus changes.
This change in resistance results in a bridge output voltage pro-
portional to the differential pressure.

5
4
3
1 2 3 4
1 Measuring cell
1 Seal diaphragm
2 Process connection
2 O-ring
3 Seal diaphragm
3 Overload diaphragm
4 Filling liquid
4 Silicon pressure sensor
5 Silicon absolute pressure sensor 1 - + 1 5 Process flange
Pe Absolute pressure as input variable
5 6 Body of measuring cell
2 7 Filling liquid
Pe
7 6

Fig. 1/24 Measuring cell for absolute pressure from the pressure series, Fig. 1/26 Measuring cell for differential pressure and flow, functional
functional diagram diagram

icenta Controls Ltd SITRANS P Pressure Transmitters – page 4 of 20

Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
Siemens FI 01 · February 2004 1/23
PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series
SITRANS P transmitter, DS III series, for level
■ Parameterization
1 The input pressure (hydrostatic pressure) acts hydraulically on
the measuring cell via the seal diaphragm on the mounting Depending on the version, there are different possibilities for
flange (2, Fig. 1/27). The differential pressure applied to the parameterizing the transmitter and for setting or scanning the
measuring cell is transmitted via the seal diaphragm (3) and the parameters.
filling liquid (9) to the silicon pressure sensor (6). If the measur- Parameterization using the input keys (local operation)
ing limits are exceeded, the overload diaphragm (5) is flexed un- The input keys can be used to simply set the most important
til the seal diaphragm rests on the measuring cell body (4), thus parameters without any additional equipment.
protecting the silicon pressure sensor from overloading. The
measuring diaphragm is flexed by the differential pressure. The Parameterization using HART communication
resistance of four piezo-resistors fitted in the diaphragm in a When parameterizing with the HART communicator, the connec-
bridge circuit thus changes. This change in resistance results in tion is made directly to the two-wire system (Fig. 1/28). When
a bridge output voltage proportional to the differential pressure. parameterizing with a laptop or PC, the connection is made via
a HART modem (Fig. 1/29).
The signals required for communication according to the HART
protocol 5.x are superimposed on the output current according
to frequency shift keying (FSK).
3 4 5 6 7

+
2
8
+ SITRANS P 230 to 1100 W Power supply
-
transmitter

1 10 HART
9 communicator

1 Flange with tube 6 Silicon pressure sensor Fig. 1/28 Communication between HART communicator and
2 Seal diaphragm on 7 O-ring transmitter
mounting flange 8 Process flange
3 Seal diaphragm 9 Filling liquid
4 Body of measuring cell 10 Capillary with filling liquid
5 Overload diaphragm of mounting flange
SITRANS P 230 to 500 W Power supply
transmitter

Fig. 1/27 Measuring cell for level, functional diagram PC or


HART laptop
modem

RS 232

Fig. 1/29 Communication between PC or laptop and transmitter

icenta Controls Ltd SITRANS P Pressure Transmitters – page 5 of 20

Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
1/24 Siemens FI 01 · February 2004
PRESSURE MEASUREMENT
Measuring instruments for pressure
SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

■ Technical data
(

SITRANS P, DS III series, for Pressure Absolute pressure Differential pres- Level
1
7MF4033 Pressure trans- Diff. pressure sure and flow 7MF4633
mitter series transmitter 7MF4433/
7MF4233 series 7MF4333 7MF4533
Application See page 1/20
Mode of operation See page 1/22
Measuring principle Piezo-resistive
Input
Measured variable Pressure Absolute pressure Differential pressure Level
and flow
Measuring range
• Span (continuously adjustable) 0.01 to 400 bar 8.3 mbar to 30 bar 8.3 mbar to 160 bar 25 mbar to 5 bar
(0.145 to 5802 psi) (0.12 to 435 psi) (0.12 to 2320 psi) (0.36 to 72.5 psi)
- Nominal pressure PN 32 1 mbar to 20 mbar
(MWP 464 psi) (0.0145 to 0.29 psi)
- Nominal pressure PN 160 1 mbar to 30 bar
(MWP 2320 psi) (0.0145 to 435 psi)
- Nominal pressure PN 420 2.5 mbar to 30 bar
(MWP 6092 psi) (0.036 to 435 psi)
• Lower measuring limit
- Measuring cell with silicone oil filling 30 mbar (0.44 psi) 0 mbar (0 psi) (absolute) -100% 1) of max. -100% of max. span
(absolute) span or 30 mbar or 30 mbar (0.44
(0.44 psi) (absolute) psi) (abs.) depend-
ing on mounting
flange
- Measuring cell with inert filling liquid
For process temperature 30 mbar (0.44 psi) (absolute) -100% 1) of max.
-20 °C < -d 60 °C span or 30 mbar
(- 4 °F < -d +140 °F) (0.44 psi) (abso-
lute)
For process temperature 30 mbar (abs.) + 20 mbar (abs.) · (- - 60 °C)/°C •-100% 1) of max.
+60 °C < -d 100 °C (max. +85 °C (0.44 psi (abs.) + 0.29 psi (abs.) · (- - 108 °F)/°F) span or
for 30-bar measuring cell) •0 mbar (abs.) +
(140 °F < -d 212 °C (max. +185 °F 20 mbar (abs.)
for 435 psi measuring cell)) x (- - 60 °C)/°C
•(0.44 psi (abs.) +
0.29 psi (abs.) ·
(- - 108 °F)/°F)
• Upper measuring limit 100% of max. span (max. 160 bar (2320 psi) with oxygen measurement 100% of max. span
and inert filling liquid)
• Start-of-scale (continuously adjustable) Between the measuring limits
Output
Output signal 4 to 20 mA
• Lower limit (continuously adjustable) 3.55 mA, factory-set to 3.84 mA
• Upper limit (continuously adjustable) 23.0 mA, factory-set to 20.5 mA or optional 22.0 mA
• Ripple (without HART communication) Ipp d 0.5% of max. output current
• Electric damping
- Adjustable time constant (T63) 0 to 100 s in steps of 0.1 s, factory-set to 0.1 s
• Current transmitter Adjustable from 3.55 to 23 mA
• Signal on alarm Adjustable from 3.55 to 23 mA
Load
• Without HART communication RB d (UH - 10.5 V) / 0.023 A in :, UH: power supply in V
• With HART communication RB 230 to 500 : (SIMATIC PDM) / 230 to 1100 : (HART communicator)
Characteristic Linear rising or falling
or square-rooted,
rising

1) -33% for 30-bar (435 psi) measuring cell


icenta Controls Ltd SITRANS P Pressure Transmitters – page 6 of 20
Siemens FI 01 · February 2004 1/25
Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

SITRANS P, DS III series, for Pressure Absolute pressure Differential pres- Level
1 7MF4033 Pressure trans-
mitter series
Diff. pressure
transmitter
sure and flow
7MF4433/
7MF4633

7MF4233 series 7MF4333 7MF4533


Accuracy
Reference conditions Increasing characteristic, start-of-scale value 0 bar (0 psi), stainless steel seal diaphragm (with level:
mounting flange without tube), silicone oil filling and room temperature (25 °C (77 °F))
r = max. span/set span = span ratio
Error in measurement with fixed-point
setting (including hysteresis and
repeatability)
- Linear characteristic
r d10 d (0.0029 · r + 0.071)% d 0.15%
10 < r d30 d (0.0045 · r + 0.071)% d 0.3%
30 < r d100 d (0.005 · r + d (0.005 · r + d (0.0075 · r +
0.05 %) 0.05%) 0.075%)
- Square-root characteristic
Flow > 50% d 0.1% at r d10
d 0.2% at
10 < r d30
Flow 25 to 50% d 0.2% at r d10
d 0.4% at
10 < r d30
• Repeatability Included in error in measurement
• Hysteresis Included in error in measurement
Response time Approx. 0.2 s Approx. 0.2 s Approx. 0.2 s, Approx. 0.2 s
(T63, without electric damping) approx. 0.3 s with
20- and 60-mbar
(0.29 and 0.87 psi)
measuring cells
Long-term drift (change in temperature d (0.25 · r)% per 5 d (0.2 · r)% per year d (0.25 · r)% per 5 years,
r30 °C (r54 °F) years max. static pressure 70 bar (1015 psi)
- 20-mbar (0.29 psi) measuring cell d (0.2 · r)% per
year
Ambient temperature effect
• At -10 to +60 °C (14 to 140 °F) d (0.1 · r + 0.2)%1)
- 250-mbar (3.63 psi) measuring cell d (0.5 · r + 0.2)2)%
- 600-mbar (8.7 psi) measuring cell d (0.3 · r + 0.2)2)%
- 1,600- and 5,000-mbar (23.2 and d (0.25 · r + 0.2)2)%
72.5 psi) measuring cells
• At -40 to -10 °C and +60 to +85 °C d (0.1 · r + 0.15)% / 10 K1)
(-40 to +14 °F and 140 to 185 °F) d (0.1 · r + 0.15)% / 18 °F)1)
- 250-mbar (3.63 psi) measuring cell d (0.25 · r +
0.15)3)% / 10 K
(d (0.25 · r +
0.15)3)% / 18 °F)
- 600-mbar(8.7 psi) measuring cell d (0.15 · r +
0.15)3)% / 10 K
(d (0.15 · r +
0.15)3)% / 18 °F)
- 1,600- and 5,000-mbar (23.2 and d (0.12 · r +
72.5 psi) measuring cells 0.15)3)% / 10 K
(d (0.12 · r +
0.15)3)% / 18 °F)
Influence of static pressure
• On start-of-scale d (0.15 · r)% per
100 bar (1450 psi)
- 20-mbar (0.29 psi) measuring cell d (0.15 · r)%
per 32 bar (464 psi)
- 250-mbar (3.63 psi) measuring cell d (0.3 · r)% per
nominal pressure
(PN (MWP))
- 600-mbar (8.7 psi) measuring cell d (0.15 · r)% per
nominal pressure
(PN (MWP))
- 1,600- and 5,000-mbar (23.2 and d (0.1 · r)% per
72.5 psi) measuring cells nominal pressure
(PN (MWP))
1) Twice the value with 20-mbar (0.29 psi) measuring cell.
2) 0.4 instead of 0.2 for 10 < r d 30.
3) Twice the value for 10 < r d 30.
icenta Controls Ltd SITRANS P Pressure Transmitters – page 7 of 20
1/26 Siemens FI 01 · February 2004
Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

SITRANS P, DS III series, for Pressure Absolute pressure Differential pres- Level
7MF4033 Pressure trans-
mitter series
Diff. pressure
transmitter
sure and flow
7MF4433/
7MF4633 1
7MF4233 series 7MF4333 7MF4533
• On span d 0.2% per d (0.1 · r)% per
100 bar (1450 psi) nominal pressure
(PN (MWP))
- 20-mbar (0.29 psi) measuring cell d 0.2% per 32 bar
(464 psi)
Influence of mounting position d 0.05 mbar (0.000725 psi) per 10° d 0.7 mbar (0.001015 psi) per 10° Dependent on filling
inclination (can be corrected using zero inclination (can be corrected using zero liquid in mounting
correction) correction) flange
Influence of power supply 0.005% per 1 V change in voltage
Rated operating conditions
Installation conditions
• Installation instructions Process connection pointing vertically Any mounting position Defined by flange
downwards
Ambient conditions
• Ambient temperature
(observe temperature class in
potentially explosive atmospheres)
- Measuring cell with silicone oil filling -40 to +85 °C (-40 to +185 °F)
30-bar (435 psi) measuring cell -40 to +85 °C (-40 to +185 °F)
(-20 to +85 °C (-4 to +185 °F) with
7MF4533)
- Measuring cell with inert filling liquid -20 to +85 °C (-4 to +185 °F)
- Digital display -30 to +85 °C (-22 to +185 °F)
• Ambient temperature limits See ambient temperature
• Storage temperature -50 to +85 °C (-58 to +185 °F)
• Climate class
- Condensation Permissible
• Degree of protection (to EN 60 529) IP 65
• Electromagnetic compatibility
- Emitted interference To EN 50 081-1
- Noise immunity To EN 50 082-2 and NAMUR NE 21
Medium conditions
• Process temperature
- Measuring cell with silicone oil filling -40 to +100 °C (-40 to +212 °F) High-press. side:
• pabs t 1 bar:
-40 to +175 °C
(-40 to +347 °F)
• pabs < 1 bar:
-40 to +80 °C
(-40 to +176 °F)
Low-press. side:
-40 to +100 °C
(-40 to +212 °F)
30-bar (435 psi) measuring cell -40 to +85 °C (-40 to +185 °F
(-20 to +85 °C (-4 to +185 °F) for
7MF4533)
- Measuring cell with inert filling liquid -20 to +100 °C (-4 to +212 °F)
30-bar (435 psi) measuring cell -20 to +85 °C (-4 to +185 °F)
• Process temperature limits See process temperature
• Maximum working pressure See page 1/21 Nominal pressure (PN (MWP))
Design
Weight (without options) Approx. 1.5 kg (3.3 lb) Approx. 4.5 kg (9.9 lb)
• To DIN (transmitter with mounting Approx.
flange, without tube) 11 to 13 kg
(24.2 to 28.7 lb)
• To ANSI (transmitter with mounting Approx.
flange, without tube) 11 to 18 kg
(24.2 to 39.7 lb
Dimensions See Fig. 1/38 See Fig. 1/39 See Fig. 1/40 See Fig. 1/44

icenta Controls Ltd SITRANS P Pressure Transmitters – page 8 of 20

Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
Siemens FI 01 · February 2004 1/27
PRESSURE MEASUREMENT
Measuring instruments for pressure
SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

SITRANS P, DS III series, for Pressure Absolute pressure Differential pres- Level
1 7MF4033 Pressure trans-
mitter series
Diff. pressure
transmitter
sure and flow
7MF4433/
7MF4633

7MF4233 series 7MF4333 7MF4533


Design (continued)
Material
• Wetted parts materials
- Connection shank Stainless steel, mat. No. 1.4401 or
Hastelloy C4, mat. No. 2.4610
- Oval flange Stainless steel, mat. No. 1.4401
- Seal diaphragm Stainless steel, mat. No. 1.4404/316L or Stainless steel, mat. No. 1.4404/316L,
Hastelloy C276, mat. No. 2.4819 Hastelloy C276, mat. No. 2.4819, Monel,
mat. No. 2.4360, tantalum or gold
- Process flanges and Stainless steel, mat. No. 1.4408 up to
sealing screw PN 160 (MWP 2320 psi), mat. No.
1.4571/316Ti for PN 420 (MWP 6092 psi),
Hastelloy C4, mat. No. 2.4610 or Monel,
mat. No. 2.4360
- O-ring FPM (Viton) or as option:
PTFE, FEP, FEPM and NBR
- High-pressure side
Seal diaphragm of mounting flange Stainless steel
316L, Monel 400,
mat. No. 2.4360,
Hastelloy B2,
mat. No. 2.4617,
Hastelloy C276,
mat. No. 2.4819,
Hastelloy C4,
mat. No. 2.4610,
tantalum, PTFE,
ECTFE
Sealing face Smooth to EN
1092-1, Form B1,
or ASME B16.5 RF
125 ... 250 AA for
stainless steel
316L, EN 1092-1,
Form B2, or ASME
B16.5 RFSF for
other materials
- Sealing material in the process flanges
For standard applications Viton
For vacuum appl. of mounting flange Copper
- Low-pressure side
Seal diaphragm Stainless steel,
mat. No. 1.4404/
316L
Process flanges and Stainless steel,
sealing screw mat. No. 1.4408
O-ring FPM (Viton)
• Non-wetted parts materials
- Electronics housing Die-cast aluminium, low in copper, GD-ALSi 12, or stainless steel precision casting, mat no. 1.4408,
polyester-based lacquer, stainless steel rating plate
- Process flange screws Steel, galvanized and yellow-passivized, or stainless steel
- Mounting bracket (option) Steel, galvanized and yellow-passivized, or stainless steel
Measuring cell filling Silicone oil or inert filling liquid (max. 160 bar (2320 psi) with oxygen measurement) Silicone oil
• Filling liquid of mounting flange Silicone oil or other
material
Process connection Connection shank G½A to DIN 16 288, Female thread ¼ - 18 NPT and
female thread ½ - 14 NPT or oval flange flange connection to DIN 19 213 with
(PN 160 ( MWP 2320 psi)) with mounting mounting thread M10 (M12 for PN 420
thread M10 or 7/16-20 UNF (MWP 6092 psi)) or 7/16-20 UNF
• High-pressure side Flange to DIN and
ANSI
• Low-pressure side Female thread ¼ -
18 NPT and flange
connection to DIN
19 213 with mount-
ing thread M10 or
7/16-20 UNF
Electrical connection Screw terminals, cable inlet via screwed gland Pg 13.5 (adapter),
M20 x 1.5 or ½ - 14 NPT, or Han 7D/Han 8U plug

icenta Controls Ltd SITRANS P Pressure Transmitters – page 9 of 20


1/28 Siemens FI 01 · February 2004
Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

SITRANS P, DS III series, for Pressure Absolute pressure Differential pres- Level
7MF4033 Pressure trans-
mitter series
Diff. pressure
transmitter
sure and flow
7MF4433/
7MF4633 1
7MF4233 series 7MF4333 7MF4533
Displays and controls
Input keys 3 for local programming directly on transmitter
Digital display Built-in, cover with window (option)
Power supply (UH)
Terminal voltage on transmitter DC 10.5 to 45 V and DC 10.5 to 30 V in intrinsically-safe mode
Ripple Upp d 0.2 V (47 to 125 Hz)
Noise Urms d 1.2 mV (0.5 to 10 kHz)
Certificates and approvals
Classification according to pressure 7MF4033, 7MF4233, 7MF4333, 7MF4433, 7MF4633
equipment directive (DGRL 97/23/EC): For gases of fluid group 1 and liquids of fluid 1; complies with requirements of
article 3, paragraph 3 (sound engineering practice)
7MF4533
For gases of fluid group 1 and liquids of fluid group 1; complies with basic safety requirements of
article 3, paragraph 1 (appendix 1); assigned to category III,
conformity evaluation module H by the TÜV Nord
Explosion protection
• Intrinsic safety "i" PTB 99 ATEX 2122
- Identification II1/2 G EEx ia IIC/IIB T4 / T5 / T6; EEx ib IIC/IIB T4 / T5 / T6
- Permissible ambient temperature -40 to +85 °C (-40 to +185 °F) temperature class T4, +70 °C (158 °F) temperature class T5,
+60 °C (140 °F) temperature class T6
- Connection To certified intrinsically-safe circuits with maximum values:
Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 :
- Effective internal inductance/capacitance Li 0.4 mH / Ci 6 nF
• Explosion-proof "d" PTB 99 ATEX 1160
- Identification II 1/2 G EEx d IIC T4 / T6
- Permissible ambient temperature -40 to +85 °C (-40 to +185 °F) temperature class T4, +60 °C (140 °F) temperature class T6
- Connection To circuits with values: UH = DC 10.5 to 45 V
• Type of protection "n" (zone 2) TÜV 01 ATEX 1696 X
- Identification II 3 G EEx nA L IIC T4 / T5 / T6
- Permissible ambient temperature -40 to +85 °C (-40 to +185 °F) temperature class T4, +70 °C (158 °F) temperature class T5,
+60 °C (140 °F) temperature class T6
- Connection To circuits with values: UH = DC 10.5 to 45 V
• Explosion protection to FM Certificate of Compliance 3008490
- Identification (XP/DIP) or (IS); (NI) CL I, DIV 1, GP ABCD T4 to T6; CL II, DIV 1, GP EFG; CL III;
CL I, ZN 0/1 AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III
- Permissible ambient temperature Ta = T4: -40 to 85 °C (-40 to +185 °F); T5: -40 to 70 °F (-40 to 158 °F); T6: -40 to 60 °C (-40 to 140 °F)
- Entity parameters According to control drawing A5E00072770A:
Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 :Li 0.4 mH, Ci 6 nF
• Explosion protection to CSA Certificate of Compliance 1153651
- Identification (XP/DIP) or (IS) CL I, DIV 1, GP ABCD T4toT6; CL II, DIV 1, GP EFG; CL III;
Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III
- Permissible ambient temperature Ta = T4: -40 to 85 °C (-40 to +185 °F); T5: -40 to 70 °F (-40 to 158 °F); T6: -40 to 60 °C (-40 to 140 °F)
- Entity parameters According to control drawing A5E00072770A:
Ui = 30 V, Ii = 100 mA, Pi = 750 mW, Ri = 300 :Li 0.4 mH, Ci 6 nF
Communication
Load when connecting a
• HART communicator 230 to 1100 :
• HART modem 230 to 500 :
Cable 2-wire screened: d3.0 km (1.86 miles), multi-core screened: d1.5 km (0.93 miles)
Protocol HART, version 5.x
PC/laptop requirements IBM-compatible, main memory > 32 Mbyte, hard disk > 70 Mbyte, RS 232 interface, VGA graphics
Software for PC/laptop Windows 95 / 98 / NT 4.0 and SIMATIC PDM

icenta Controls Ltd SITRANS P Pressure Transmitters – page 10 of 20

Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk
Siemens FI 01 · Februarywww.icenta.co.uk
2004 1/29
PRESSURE MEASUREMENT
Measuring instruments for pressure
SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

■ Ordering data Order No. ■ Ordering data Order code


1 .

SITRANS P transmitter for pressure, } 7MF4033- Further designs


two-wire system, DS III series 77 7 7 7 - 7 7 7 7
Please add "Z" to Order No. and specify Order code(s).
Meas. cell filling Meas. cell cleaning
Transmitter with mounting bracket made of
Silicone oil Normal } 1 • Steel A01
Inert liquid3) Grease-free 3 • Stainless steel A02
Span Han 7D plug (metal, gray) A30
0.01 to 1 bar (0.15 to 14.5 psi) } B Han 8U plug (instead of Han 7D) A31
0.04 to 4 bar (0.58 to 58.0 psi) } C
0.16 to 16 bar (2.32 to 232 psi) } D Type plate inscription (instead of German)
0.63 to 63 bar (9.14 to 914 psi) } E • English B11
1.6 to 160 bar (23.2 to 2320 psi) } F • French B12
4.0 to 400 bar (58.0 to 5802 psi) } G • Spanish B13
• Italian B14
Wetted parts materials
English rating plate,
Seal diaphragm Process connection pressure units in inH2O or psi B21
Stainless steel Stainless steel } A
Hastelloy Stainless steel B Manufacturer’s test certificate M (Calibration certificate)
Hastelloy Hastelloy C to DIN 55 350, Part 18 and to ISO 8402 C11
Version for remote seal Y0 Acceptance test certificate B to EN 10 204-3.1.B C12
Factory certificate to EN 10 204-2.2 C14
Process connection Certificate "Functional safety" (SIL) C20
• Connection shank G½A } 0 Setting of upper limit of D05
• Female thread ½ - 14 NPT 1 output signal to 22.0 mA
• Oval flange made of stainless steel, Sour gas version to NACE D07
max. span 160 bar (2320 psi) (only together with seal diaphragm made of Hastelloy)
- Mounting thread 7/16- 20 UNF 2
- Mounting thread M10 3 IP 68 (not together with Han 7D/Han 8U plug, Pg 13.5 D12
screwed gland and measuring cells d 63 bar (d 914 psi))
Non-wetted parts materials
Digital indicator beside control keys D27
• Housing made of die-cast aluminium } 0 (only with transmitter 7MF4033-77770-7A7 6 or
• Housing stainl. steel precision casting 3 7MF4033-77770-7A7 7-Z, Y21 or Y22 + Y01)
Design Use in or at zone 1D/2D (only together with basic device E01
with type of protection "Intrinsically-safe")
• Standard version 1
• International version, Use at zone 0 (basic unit EEx ia) E02
English label inscriptions, documenta- Oxygen application (max. 160 bar (2320 psi) with oxy- E10
tion in 5 languages on CD } 2 gen measurement and inert filling liquid)
Explosion protection Additional information
• Without explosion protection A Please add "Z" to Order No. and specify Order code(s)
• With explosion protection (ATEX) and plain text.
Type of protection:
Measuring range to be set,
- "Intrinsic safety" (EEx ia) B
specify in plain text:
- "Explosion-proof" (EEx d) 1) D
- "Intrinsic safety and explosion-proof" Y01: ... to ... mbar, bar, kPa, MPa, psi, ... Y01
(EEx ia and EEx d) 1) } P
Measuring-point number/identification (max. 16 charac-
- "n" (zone 2) E
ters), specify in plain text: Y15: ........... Y15
• With explosion protection (FM + CSA)
- intrinsic safe and explosion-proof Measuring-point text (max. 27 characters),
(is + xp) 1) NC specify in plain text: Y16: ........... Y16

Electrical connection/ Entry of HART address (TAG) (max. 8 characters),


cable inlet specify in plain text: Y17: ........... Y17
• Screwed gland Pg 13.5 2) A Setting for digital display in pressure units,
specify in plain text (standard setting: mA):
• Screwed gland M20 x 1.5 } B
Y21: mbar, bar, kPa, MPa, psi, ... Y21
• Screwed gland ½ - 14 NPT C
Note on Y21
• Han 7D plug 2) D
The following pressure units can be selected:
Indicator bar, mbar, mm H2O*), in H2O*), ft H2O*), mm HG, in HG,
• Without indicator (digital display hid- psi, Pa, kPa, MPa, g/cm2, kg/cm2, mA, Torr, ATM or %
den, setting: mA) } 1 (*) reference temperature 20 °C)
• With indicator (digital display visible, Setting for digital display in non-pressure units,
setting: mA) 6 specify in plain text:
• With indicator (digital display visible, Y22: ..... to ..... l/min, m3/h, m, USgpm, ... Y22 + Y01
setting as specified, Order code Y21
(specification of measuring range in pressure units
or Y22 required) 7
(Y01) is essential)
} Available ex stock. Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the
Example for ordering: factory.
Item line 1: 7MF4033-1EA00-1AA7-Z Scope of delivery: Transmitter as ordered (Instruction Manual is extra
B line: A01 + Y01 + Y21 ordering item (see accessories on page 1/66)).
C line Y01: 10 to 20 bar (145 psi to 290 psi)
C line Y21: bar (psi) Power supply units: see Section 6.
1) Without explosion-proof cable gland.
2
) Not together with type of protection "Explosion-proof".
3) For oxygen application please add Order Code E10.

icenta Controls SITRANS P Pressure Transmitters – page 11 of 20


1/30Ltd Siemens FI 01 · February 2004

Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
PRESSURE MEASUREMENT
Measuring instruments for pressure
SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

■ Ordering data Order No. ■ Ordering data Order code


.

SITRANS P transmitter for absolute Further designs


1
pressure, from pressure transmitter 7MF4233-
series, two-wire system, DS III series 77 7 7 7 - 7 7 7 7 Please add "Z" to Order No. and specify Order code(s).

Meas. cell filling Meas. cell cleaning Transmitter with mounting bracket made of
Silicone oil Normal 1 • Steel A01
Inert liquid4) Grease-free 3 • Stainless steel A02
Span Han 7D plug (metal, gray) A30
8.3 to 250 mbar (0.12 to 3.63 psi) E) D Han 8U plug (instead of Han 7D) A31
43 to 1,300 mbar (0.62 to 18.9 psi) E) F
160 to 5,000 mbar (2.32 to 72.5 psi) E) G Type plate inscription (instead of German)
1 to 30 bar (14.5 to 435 psi) H • English B11
Wetted parts materials • French B12
Seal diaphragm Process connection • Spanish B13
Stainless steel Stainless steel A • Italian B14
Hastelloy Stainless steel E) B English rating plate,
Hastelloy Hastelloy E) C pressure units in inH2O or psi B21
1
Version for remote seal ) Y0
Manufacturer’s test certificate M (Calibration certificate)
Process connection to DIN 55 350, Part 18 and to ISO 8402 C11
• Connection shank G½A 0 Acceptance test certificate B to EN 10 204-3.1.B C12
• Female thread ½ - 14 NPT 1 Factory certificate to EN 10 204-2.2 C14
Certificate "Functional safety" (SIL) C20
• Oval flange made of stainless steel,
max. span 160 bar (2320 psi) Setting of upper limit of output signal to 22.0 mA D05
- Mounting thread 7/16 - 20 UNF 2 Sour gas version to NACE D07
- Mounting thread M10 3 (only together with seal diaphragm made of Hastelloy)
Non-wetted parts materials IP 68 (not together with Han 7D/Han 8U plug, Pg 13.5 D12
• Housing made of die-cast aluminium 0 screwed gland)
• Housing stainl. steel precision casting 3 Digital indicator beside control keys D27
Design (only with transmitter 7MF4233-77770-7A7 6 or
7MF4233-77770-7A7 7-Z, Y21 or Y22 + Y01)
• Standard version 1
Use in or at zone 1D/2D (only together with basic device E01
• International version, with type of protection "Intrinsically-safe")
English label inscriptions, documenta-
tion in 5 languages on CD 2 Use at zone 0 (basic unit EEx ia) E02
Explosion protection Oxygen application (max. 160 bar (2320 psi) with oxy- E10
gen measurement and inert filling liquid)
• Without explosion protection A
• With explosion protection (ATEX) Additional information
Type of protection: Please add "Z" to Order No. and specify Order code(s)
- "Intrinsic safety" (EEx ia) B and plain text.
- "Explosion-proof" (EEx d) 2) D
- "Intrinsic safety and explosion-proof" Measuring range to be set, specify in plain text:
(EEx ia and EEx d) 2) P Y01: ... to ... mbar, bar, kPa, MPa, psi, ... Y01
- "n" (zone 2) E
Measuring-point number/identification (max. 16 charac-
• With explosion protection (FM + CSA) ters), specify in plain text: Y15: ........... Y15
- intrinsic safe and explosion-proof
(is + xp) 2) NC Measuring-point text (max. 27 characters),
specify in plain text: Y16: ........... Y16
Electrical connection/
cable inlet Entry of HART address (TAG) (max. 8 characters),
• Screwed gland Pg 13.5 3) A specify in plain text: Y17: ........... Y17
• Screwed gland M20 x 1.5 B Setting for digital display in pressure units,
specify in plain text (standard setting: mA):
• Screwed gland ½ - 14 NPT C
Y21: mbar, bar, kPa, MPa, psi, ... Y21
• Han 7D plug 3) D
(see "Additional information" on page 1/27 for pressure
Indicator dimensions selectable for "Y21")
• Without indicator (digital display hid- Setting for digital display in non-pressure units,
den, setting: mA) 1 specify in plain text:
• With indicator (digital display visible, Y22: ..... to ..... l/min, m3/h, m, USgpm, ... Y22 + Y01
setting: mA) 6
(specification of measuring range in pressure units
• With indicator (digital display visible, (Y01) is essential)
setting as specified, Order code Y21
or Y22 required) 7 Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the fac-
tory.
E) Combinations with the versions identified by E) are subject to the
export regulations AL: 2B230, ECCN: N. Example for ordering: see page 1/30
Scope of delivery: Transmitter as ordered (Instruction Manual is extra
ordering item (see accessories on page 1/66)).
Power supply units: see Section 6.
1) Version 7MF4233-1DY... only up to max. span 200 mbar (2.9 psi)
2) Without explosion-proof cable gland.
3) Not together with type of protection "Explosion-proof".
4
) For oxygen application please add Order Code E10.

icenta Controls Ltd SITRANS P Pressure Transmitters – page 12 of 20


Siemens FI 01 · February 2004 1/31
Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

■ Ordering data Order No. ■ Ordering data Order code


1 .

SITRANS P transmitter for absolute Further designs


pressure, from differential pressure 7MF4333- Please add "Z" to Order No. and specify Order code(s).
transmitter series, two-wire system, 77 7 7 7 - 7 7 7 7
DS III series Transmitter with mounting bracket made of
• Steel A01
Meas. cell filling Meas. cell cleaning • Stainless steel A02
Silicone oil Normal 1 Instead of FPM (Viton), process flange O-ring made of:
Inert liquid6) Grease-free 3 • PTFE (Teflon) A20
Span • FEP (with silicone core, approved for food) A21
8.3 to 250 mbar (0.12 to 3.63 psi) E) D • FFPM (Kalrez, Compound 4079) A22
43 to 1,300 mbar (0.62 to 18.9 psi) E) F • NBR (Buna N) A23
160 to 5,000 mbar (2.32 to 72.5 psi) E) G Han 7D plug (metal, gray) A30
1.0 to 30 bar (14.5 to 435 psi) H Han 8U plug (instead of Han 7D) A31
5.3 to 100 bar (76.9 to 1,450 psi) KE
Sealing screws (¼ - 18 NPT) with valve in material of pro- A40
Wetted parts materials cess flange
Seal diaphragm Parts of meas. cell Type plate inscription (instead of German)
Stainless steel Stainless steel A • English B11
Hastelloy Stainless steel E) B • French B12
Hastelloy Hastelloy E) C • Spanish B13
Tantalum Tantalum E • Italian B14
Monel Monel H English rating plate,
Gold Gold L pressure units in inH2O or psi B21
Version for remote seal 1) Y
Manufacturer’s test certificate M (Calibration certificate)
Process connection to DIN 55 350, Part 18 and to ISO 8402 C11
Female thread ¼ - 18 NPT with flange Acceptance test certificate B to EN 10 204-3.1.B C12
connection to DIN 19 213 Factory certificate to EN 10 204-2.2 C14
Certificate "Functional safety" (SIL) C20
• With sealing screw opposite process
connection Setting of upper limit of output signal to 22.0 mA D05
- Mounting thread M10 0 Sour gas version to NACE D07
7/ - 20 UNF
- Mounting thread 16 2 (only together with seal diaphragm made of Hastelloy)
• Sealing screw on side of process IP 68 (not together with Han 7D/Han 8U plug, Pg 13.5 D12
2
flanges ) screwed gland)
- Mounting thread M10 4
7/ - 20 UNF Digital indicator beside control keys D27
- Mounting thread 16 6
(only with transmitter 7MF4333-77772-7A7 6 or
Non-wetted parts materials 7MF4333-77772-7A7 7-Z, Y21 or Y22 + Y01)
Process flange Electronics housing Use in or at zone 1D/2D (only together with basic device E01
screws with type of protection "Intrinsically-safe")
Stainless steel Die-cast aluminium 2 Use at zone 0 (basic unit EEx ia) E02
Stainless steel Stain. steel prec. cast. 3
Oxygen application (max. 160 bar (2320 psi) with oxy- E10
Design gen measurement and inert filling liquid)
• Standard version 1 Interchanging of process connection side H01
• International version, Vent on side for gas measurements H02
English label inscriptions, documenta-
tion in 5 languages on CD 2 Process flange made of:
• Hastelloy K01
Explosion protection • Monel K02
• Without explosion protection A • Stainless steel with PVDF insert (max. PN 10 (MWP 145 K04
psi), max. temperature of medium 90 °C (194 °F))
• With explosion protection (ATEX)
Type of protection:
- "Intrinsic safety" (EEx ia) B
- "Explosion-proof" (EEx d) 3) D
- "Intrinsic safety and explosion-proof"
(EEx ia +EEx d) 3) P
- "n" (zone 2) E
• With explosion protection (FM + CSA)
- intrinsic safe and explosion-proof
(is + xp) 3) 5) NC
Electrical connection/cable inlet
• Screwed gland Pg 13.5 4) A
• Screwed gland M20 x 1.5 B
• Screwed gland ½ - 14 NPT C
• Han 7D plug 4) D
Indicator
• Without indicator (digital display hid- E) Combinations with the versions identified by E) are subject to the
den, setting: mA) 1 export regulations AL: 2B230, ECCN: N.
1) Version 7MF4333-1DY... only up to max. span 200 mbar (2.9 psi).
• With Indicator (digital display visible, 2) Not for measuring cells 5.3 to 160 bar (76.9 to 2320 psi).
setting: mA) 6 3) Without explosion-proof cable gland.
• With indicator (digital display visible, 4) Not together with type of protection "Explosion-proof".
setting as specified, Order code Y21 5) Only together with seal diaphragm made of stainless steel or Hastelloy.
or Y22 required) 7 6
) For oxygen application please add Order Code E10.

icenta Controls Ltd SITRANS P Pressure Transmitters – page 13 of 20


1/32 Siemens FI 01 · February 2004
Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

■ Ordering data Order code


Additional information
1
Please add "Z" to Order No. and specify Order code(s)
and plain text.
Measuring range to be set, specify in plain text:
Y01: ... to ... mbar, bar, kPa, MPa, psi, ... Y01
Measuring-point number/identification
(max. 16 characters), specify in plain text:
Y15: .............................................. Y15
Measuring-point text (max. 27 characters),
specify in plain text:
Y16: ............................................... Y16
Entry of HART address (TAG) (max. 8 characters),
specify in plain text:
Y17: ............................................... Y17
Setting for digital display in pressure units,
specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ... Y21
(see "Additional information" on page 1/27 for pressure
dimensions selectable for "Y21")
Setting for digital display in non-pressure units,
specify in plain text:
Y22: ..... to ..... l/min, m3/h, m, USgpm, ... Y22 + Y01
(specification of measuring range in pressure units
(Y01) is essential)
Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the fac-
tory.
Example for ordering: see page 1/30.
Power supply units: see Section 6.
Scope of delivery: Transmitter as ordered (Instruction Manual is extra
ordering item (see accessories on page 1/66)).

icenta Controls Ltd SITRANS P Pressure Transmitters – page 14 of 20

Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
Siemens FI 01 · February 2004 1/33
PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

■ Ordering data Order No. ■ Ordering data Order code


1 .

SITRANS P transmitter for differential Further designs


pressure and flow, two-wire system, } 7MF4433- Please add "Z" to Order No. and specify Order code(s).
DS III series, PN 32/160 77 7 7 7 - 7 7 7 7
(MWP 464/2320 psi) Transmitter with mounting bracket made of
• Steel A01
Meas. cell filling Meas. cell cleaning • Stainless steel A02
Silicone oil Normal } 1 Instead of FPM (Viton), process flange O-ring made of:
Inert liquid6) Grease-free 3 • PTFE (Teflon) A20
PN 32 (MWP 464 psi), span • FEP (with silicone core, approved for food) A21
1 to 20 mbar 1) (0.0145 to 0.29 psi) } B • FFPM (Kalrez, Compound 4079) A22
PN 160 (MWP 2320 psi), span • NBR (Buna N) A23
1 to 60 mbar (0.0145 to 0.87 psi) } C Han 7D plug (metal, gray) A30
2.5 to 250 mbar (0.036 to 3.63 psi) } D Han 8U plug (instead of Han 7D) A31
6 to 600 mbar (0.087 to 8.70 psi) } E
16 to 1,600 mbar (0.232 to 23.2 psi) } F Sealing screws (¼ - 18 NPT) with valve in material of pro- A40
50 to 5,000 mbar (0.725 to 72.5 psi) } G cess flange
0.3 to 30 bar (4.35 to 435 psi) } H Type plate inscription (instead of German)
• English B11
Wetted parts materials
• French B12
(process flange made of stainless steel)
• Spanish B13
Seal diaphragm Parts of meas. cell • Italian B14
Stainless steel Stainless steel } A English rating plate,
Hastelloy Stainless steel B pressure units in inH2O or psi B21
Hastelloy Hastelloy C
Tantalum 2) Tantalum E Manufacturer’s test certificate M (Calibration certificate)
Monel ) 2
Monel H to DIN 55 350, Part 18 and to ISO 8402 C11
Gold )2
Gold L Acceptance test certificate B to EN 10 204-3.1.B C12
Version for remote seal Y Factory certificate to EN 10 204-2.2 C14
Certificate "Functional safety" (SIL) C20
Process connection
Setting of upper limit of output signal to 22.0 mA D05
Female thread ¼ - 18 NPT with flange
connection to DIN 19 213 Sour gas version to NACE D07
(only together with seal diaphragm made of Hastelloy)
• Sealing screw opposite process conn.
- Mounting thread M10 } 0 IP 68 (not together with Han 7D/Han 8U plug, Pg 13.5 D12
- Mounting thread 7
/16 - 20 UNF 2 screwed gland)
• Sealing screw on side of process Digital indicator beside control keys D27
flanges (only with transmitter 7MF4433-77772-7A7 6 or
- Mounting thread M10 4 7MF4433-77772-7A7 7-Z, Y21 or Y22 + Y01)
7/ - 20 UNF
- Mounting thread 16 6 Use in or at zone 1D/2D (only together with basic device E01
with type of protection "Intrinsically-safe")
Non-wetted parts materials
Process flange Electronics housing Use at zone 0 (basic unit EEx ia) E02
screws TÜV Approval to AD/TRD E06
Stainless steel Die-cast aluminium } 2 Over-filling safety device for flammable and non-flamma- E08
Stainless steel Stain. steel prec. cast. 3 ble liquids (max. PN 32 (MWP 464 psi)) (basic unit EEx
ia) nach WHG und VbF
Design
• Standard version 1 Oxygen application (max. 160 bar (2320 psi) with oxy- E10
gen measurement and inert filling liquid)
• International version,
English label inscriptions, documenta- Interchanging of process connection side H01
tion in 5 languages on CD } 2 Vent on side for gas measurements H02
Explosion protection Stainless steel process flanges for vertical differential H03
• Without explosion protection A pressure lines (not together with K01, K02 and K04) 1)
• With explosion protection (ATEX) Process flange made of Hastelloy K01
Type of protection: Process flange made of Monel K02
- "Intrinsic safety" (EEx ia) B Process flange made of stainless steel with PVDF insert K04
- "Explosion-proof" (EEx d) 3) D (max. PN 10 (MWP 145 psi), max. temperature of
- "Intrinsic safety and explosion-proof" medium 90 °C (194 °F))
(EEx ia +EEx d) 3) } P } Available ex stock.
- "n" (zone 2) E
• With explosion protection (FM + CSA)
- intrinsic safe and explosion-proof
(is + xp) 3) 5) NC
Electrical connection/cable inlet
• Screwed gland Pg 13.5 4) A
• Screwed gland M20 x 1.5 } B
• Screwed gland ½ - 14 NPT C
• Han 7D plug 4) D
Indicator 1
) Not suitable for connection of remote seal.
• Without indicator (hidden, setting: mA)} 1 2) Only together with max. spans 250, 1600, 5000 and 30000 mbar (3.63,
• With indicator (digital display visible, 23.2, 72.5 and 435 psi).
setting: mA) 6 3
) Without explosion-proof cable gland.
• With indicator (digital display visible, 4) Not together with type of protection "Explosion-proof".
setting as specified, Order code Y21 5) Only together with seal diaphragm made of stainless steel or Hastelloy.
or Y22 required) 7 6
) For oxygen application please add Order Code E10.

icenta Controls Ltd SITRANS P Pressure Transmitters – page 15 of 20


1/34 Siemens FI 01 · February 2004
Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

■ Ordering data Order code


Additional information
1
Please add "Z" to Order No. and specify Order code(s)
and plain text.
Measuring range to be set, specify in plain text:
• With linear characteristic:
Y01: ... to ... mbar, bar, kPa, MPa, psi, ... Y01
• With square-rooted characteristic:
Y02: ... to ... mbar, bar, kPa, MPa, psi, ... Y02
Measuring-point number/identification
(max. 16 characters), specify in plain text:
Y15: .............................................. Y15
Measuring-point text (max. 27 characters),
specify in plain text:
Y16: .............................................. Y16
Entry of HART address (TAG) (max. 8 characters),
specify in plain text:
Y17: .............................................. Y17
Setting for digital display in pressure units,
specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ... Y21
(see "Additional information" on page 1/27 for pressure
dimensions selectable for "Y21")
Setting for digital display in non-pressure units,
specify in plain text:
Y22: ..... to ..... l/min, m3/h, m, USgpm, ... Y221) +
(specification of measuring range in pressure units (Y01 Y01 or
or Y02) is essential) Y02
Only the settings for "Y01", "Y02", "Y21", "Y22" and "D05" can be made in
factory.
Example for ordering: see page 1/30.
Scope of delivery: Transmitter as ordered (Instruction Manual is extra
ordering item (see accessories on page 1/66)).
Power supply units: see Section 6.

1
) Not together with over-filling safety device for flammable and non-
icenta Controls Ltd liquids (Order code "E08")
flammable SITRANS P Pressure Transmitters – page 16 of 20

Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
Siemens FI 01 · February 2004 1/35
PRESSURE MEASUREMENT
Measuring instruments for pressure
SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

■ Ordering data Order No. ■ Ordering data Order code


1 SITRANS P transmitter for differential
pressure and flow, two-wire system, 7MF4533
Further designs
DS III series, PN 420 (MWP 6092 psi) 77777-7 777 Please add "Z" to Order No. and specify Order code(s).
Meas. cell filling Meas. cell cleaning Transmitter with mounting bracket made of
• Steel A01
Silicone oil Normal 1
• Stainless steel A02
Span
Instead of FPM (Viton), process flange O-ring made of:
2.5 to 250 mbar (0.036 to 3.63 psi) D
• PTFE (Teflon) A20
6 to 600 mbar (0.087 to 8.7 psi) E
• FEP (with silicone core, approved for food) A21
16 to 1,600 mbar (0.23 to 23.2 psi) F
• FFPM (Kalrez, Compound 4079) A22
50 to 5,000 mbar (0.73 to 72.5 psi) G
• NBR (Buna N) A23
0.3 to 30 bar (4.35 to 435 psi) H
Han 7D plug (metal, gray) A30
Wetted parts materials
Han 8U plug (instead of Han 7D) A31
(process flange made of stainless steel)
Seal diaphragm Parts of meas. cell Sealing screw (¼ - 18 NPT) with valve in material of pro- A40
cess flange
Stainless steel Stainless steel A
Hastelloy Stainless steel B Type plate inscription (instead of German)
1 • English B11
Gold ) Gold L
• French B12
Process connection • Spanish B13
Female thread ¼ - 18 NPT and flange • Italian B14
connection to DIN 19213
English rating plate, pressure units in inH2O or psi B21
• Sealing screw opposite process con-
nection Manufacturer’s test certificate M (Calibration certificate) C11
- Mounting thread M12 1 to DIN 55 350, Part 18 and to ISO 8402
7/ - 20 UNF Acceptance test certificate B to EN 10 204-3.1.B C12
- Mounting thread 16 3
Factory certificate to EN 10 204-2.2 C14
• Sealing screw on side of process Certificate "Functional safety" (SIL) C20
flanges
- Mounting thread M12 5 Setting of upper limit of output signal to 22.0 mA D05
7/ - 20 UNF
- Mounting thread 16 7
Sour gas version to NACE (only together with seal dia- D07
Non-wetted parts materials phragm made of Hastelloy)
Process flange Electronics housing IP 68 (not together with Han 7D/Han 8U plug, Pg 13.5 D12
screws screwed gland)
Stainless steel Die -cast aluminium 2 Use in or at zone 1D/2D (only together with basic device E01
Stainless steel Stain. steel prec. cast. 3 with type of protection "Intrinsically-safe")
Design Use at zone 0 (basic unit EEx ia) E02
• Standard version 1 Digital indicator beside control keys D27
• International version, (only with transmitter 7MF4533-77772-7A7 6 or
English label inscriptions, documenta- 7MF4533-77772-7A7 7-Z, Y21 or Y22 + Y01)
tion in 5 languages on CD 2
Interchanging of process connection side H01
Explosion protection
Stainless steel process flanges for vertical differential H03
• Without explosion protection A pressure lines
• With explosion protection (ATEX)
Type of protection:
- "Intrinsic safety" (EEx ia) B
- "Explosion-proof" (EEx d) 2) D
- "Intrinsic safety and explosion-proof"
(EEx ia +EEx d) 2) P
- "n" (zone 2) E
• With explosion protection (FM + CSA)
- intrinsic safe and explosion-proof
(is + xp) 2) 4), max. PN 360 NC
Electrical connection/cable inlet
• Screwed gland Pg 13.5 3) A
• Screwed gland M20 x 1.5 B
• Screwed gland ½ - 14 NPT C
• Han 7D plug 3) D
Indicator
• Without indicator (digital display hid- 1
den, setting: mA)
• With indicator (digital display visible,
setting: mA) 6
• With indicator (digital display visible,
setting as specified, Order code Y21
or Y22 required) 7
1) Only together with max. spans 250, 1600, 5000 and 30000 mbar (3.63,
Example for ordering: see page 1/30.
23.2, 72.5 and 435 psi) and process flange screws made of stainless
Scope of delivery: Transmitter as ordered (Instruction Manual is extra
steel.
ordering item (see accessories on page 1/66)). 2) Without explosion-proof cable gland.
Power supply units: see Section 6. 3
) Not together with type of protection "Explosion-proof".
4) Only together with seal diaphragm made of stainless steel or Hastelloy.

icenta Controls Ltd SITRANS P Pressure Transmitters – page 17 of 20


1/36 Siemens FI 01 · February 2004
Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

■ Ordering data Order code


Additional information
1
Please add "Z" to Order No. and specify Order code(s)
and plain text.
Measuring range to be set, specify in plain text:
• With linear characteristic:
Y01: ... to ... mbar, bar, kPa, MPa, psi, ... Y01
• With square-rooted characteristic:
Y02: ... to ... mbar, bar, kPa, MPa, psi, ... Y02
Measuring-point number/identification
(max. 16 characters), specify in plain text:
Y15: .............................................. Y15
Measuring-point text (max. 27 characters),
specify in plain text:
Y16: ............................................... Y16
Entry of HART address (TAG) (max. 8 characters),
specify in plain text:
Y17: ............................................... Y17
Setting for digital display in pressure units,
specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ... Y21
(see "Additional information" on page 1/27 for pressure
dimensions selectable for "Y21")
Setting for digital display in non-pressure units,
specify in plain text:
Y22: ..... to ..... l/min, m3/h, m, USgpm, ... Y22 + Y01
(specification of measuring range in pressure units (Y01 or Y02
or Y02) is essential)
Only the settings for "Y01" or "Y02", "Y21", "Y22" or "D05" can be made in
factory.

icenta Controls Ltd SITRANS P Pressure Transmitters – page 18 of 20

Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
Siemens FI 01 · February 2004 1/37
PRESSURE MEASUREMENT
Measuring instruments for pressure
SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

■ Ordering data Order No. ■ Ordering data Order code


1 .

SITRANS P transmitter for level, Further designs


two-wire system, 7MF4633-
DS III series 77Y77-7 777 Please add "Z" to Order No. and specify Order code(s).

Meas. cell filling Meas. cell cleaning Instead of FPM (Viton), process flange O-ring made of:
• PTFE (Teflon) A20
Silicone oil Normal 1 • FEP (with silicone core, approved for food) A21
Span • FFPM (Kalrez, Compound 4079) A22
25 to 250 mbar (0.36 to 3.63 psi) D • NBR (Buna N) A23
25 to 600 mbar (0.36 to 8.7 psi) E Han 7D plug (metal, gray) A30
53 to 1,600 mbar (0.77 to 23.2 psi) F Han 8U plug (instead of Han 7D) A31
0.16 to 5.0 bar (2.32 to 72.5 psi) G
Sealing screws (¼ - 18 NPT) with valve in material of pro- A40
Process connection of low-pressure cess flange
side
Type plate inscription (instead of German)
Female thread ¼ - 18 NPT and flange • English B11
connection to DIN 19213 with mounting • French B12
thread • Spanish B13
• M10 0 • Italian B14
• 7/16 - 20 UNF 2 English rating plate, pressure units in inH2O or psi B21
Non-wetted parts materials Manufacturer’s test certificate M (Calibration certificate) C11
to DIN 55 350, Part 18 and to ISO 8402
Process flange Electronics housing Acceptance test certificate B to EN 10 204-3.1.B C12
screws Factory certificate to EN 10 204-2.2 C14
Stainless steel Die-cast aluminium Certificate "Functional safety" (SIL) C20
2
Stainless steel Stain. steel prec. cast. 3 Setting of upper limit of output signal to 22.0 mA D05
Design IP 68 (not together with Han 7D/Han 8U plug, Pg 13.5 D12
• Standard version 1 screwed gland)
• International version, Use in or at zone 1D/2D (only together with basic device E01
English label inscriptions, documenta- with type of protection "Intrinsically-safe")
tion in 5 languages on CD 2 Use at zone 0 (basic unit EEx ia) E02
Explosion protection Over-filling safety device for flammable and non-flamma- E08
• Without explosion protection A ble liquids (max. PN 32 (MWP 464 psi)) (basic unit EEx
• With explosion protection (ATEX) ia) to WHG and VbF
Type of protection: Interchanging of process connection side H01
- "Intrinsic safety" (EEx ia) B
- "Explosion-proof" (EEx d) 1) D
- "Intrinsic safety and explosion-proof" Additional information
(EEx ia +EEx d) 1) P Please add "Z" to Order No. and specify Order code(s)
- "n" (zone 2) E and plain text.
• With explosion protection (FM + CSA)
- intrinsic safe and explosion-proof Measuring range to be set, specify in plain text:
(is + xp) 1) 3) NC Y01: ... to ... mbar, bar, kPa, MPa, psi, ... Y01
Electrical connection/cable inlet Measuring-point number/identification
• Screwed gland Pg 13.5 2) A (max. 16 characters), specify in plain text:
Y15: .............................................. Y15
• Screwed gland M20 x 1.5 B
Measuring-point text (max. 27 characters),
• Screwed gland ½ - 14 NPT C specify in plain text:
• Han 7D plug 2) D Y16: ............................................... Y16
Indicator Entry of HART address (TAG) (max. 8 characters),
• Without indicator (digital display hid- specify in plain text:
den, setting: mA) 1 Y17: ............................................... Y17
• With indicator (digital display visible, Setting for digital display in pressure units,
setting: mA) 6 specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ... Y21
• With indicator (digital display visible,
setting as specified, Order code Y21 (see "Additional information" on page 1/23 for pressure
or Y22 required) 7 dimensions selectable for "Y21")
Setting for digital display in non-pressure units,
Ordering note: 1st order item: Transmitter 7MF4633-... specify in plain text:
2nd order item: Mounting flange 7MF4912-3...
Y22: ..... to ..... l/min, m3/h, m, USgpm, ... Y224) +
Example for ordering: (specification of measuring range in pressure units Y01
Item line 1: 7MF4633-1EY20-1AA1-Z (Y01) is essential)
B line: Y01
C line: Y01: 80 to 143 mbar (1.16 to 2.1 psi) Only the settings for "Y01", "Y21", "Y22" and "D05" can be made in the fac-
Item line 2: 7MF4912-3GE01 tory.
Scope of delivery: Transmitter as ordered (Instruction Manual is extra
ordering item (see accessories on page 1/66)).
Power supply units: see Section 6.
1
) Without explosion-proof cable gland.
2
) Not together with type of protection "Explosion-proof".
3) Only together with seal diaphragm made of stainless steel or Hastelloy.
4
) Not together with over-filling safety device for flammable and non-
flammable liquids (Order code "E08")

icenta Controls Ltd SITRANS P Pressure Transmitters – page 19 of 20


1/38 Siemens FI 01 · February 2004

Tel: 0845 895 1020 Fax: 0845 895 1021 Email: info@icenta.co.uk www.icenta.co.uk
PRESSURE MEASUREMENT

Measuring instruments for pressure


SITRANS P transmitters for pressure, absolute pressure, diff. pressure, flow, level
DS III series

■ Ordering data Order No. Order code


.

Mounting flange 7MF4912-


1
Directly fitted onto SITRANS P 71 7 7 7 7 777
transmitter for level,
for
DS III series 3
Flange Nom. diam. Nom. press.
Connection DN 80 PN 40 D
to DN 100 PN 16 G
EN 1092-1 PN 40 H
Connection 3 inch class 150 Q
to class 300 R
ASME 4 inch class 150 T
B16.5 class 300 U
Other version Z J1Y
Add Order code and plain text:
Nominal diameter: ...; Nom. pressure: ...
Wetted parts materials
• Stainless stee 316L A
- Coated with PFA 1) D
- Coated with PTFE 1) E0
- Coated with ECTFE 1) F
• Monel 400, mat. No. 2.4360 G
• Hastelloy B2, mat. No. 2.4617 H
• Hastelloy C276, mat. No. 2.4819 J
• Hastelloy C4, mat. No. 2.4610 U
• Tantalum K
Other version Z K1Y
Add Order code and plain text:
Wetted parts materials: ...
Sealing face: see "Technical data"
Tube length
• Without tube 0
• 50 mm (1.97 inch) 1
• 100 mm (3.94 inch 2
• 150 mm (5.90 inch) 3
• 200 mm (7.87 inch) 4
Filling liquid
• Silicone oil M5 1
• Silicone oil M50 2
• High-temperature oil 3
• Halocarbon oil (for O2 measurements) 4
• Vegetable oil 5
• Glycerine/water 2) 6
Other version 9 M1Y
Add Order code and plain text:
Filling liquid: ....
Order code
Further designs
Please add "Z" to Order No. and specify
Order code(s).
With spark arrestor for mounting at A01
zone 0 (including documentation)
Manufacturer’s test certificate M (Cali- C11
bration certificate) to DIN 55 350, Part
18, and to ISO 8402
Acceptance test certificate B to C12
EN 10 204-3.1 B
Vacuum-resistant design (for use in vac- V04
uum range)
Calculation of span of associated trans- Y05
mitter (enclose filled-in questionnaire
with order)
Note:
Suffix "Y01" required with transmitter!

1)For vacuum on request.


2)Not suitable for use in low-pressure range.
Example for ordering: see page 1/38.

icenta Controls Ltd SITRANS P Pressure Transmitters – page 20 of 20


Siemens FI 01 · February 2004 1/39