Sei sulla pagina 1di 4

Switch Firmware Version 8.0.14.

19

50948-34 Rev A
QLogic Corporation
All rights reserved

Table of Contents
1 Switch Models
2 Version and Date
3 Changes
4 Bug Fixes
5 Known Issues
6 Additional Information
7 Trademarks
8 Notices
9 Contacting Support

1 Switch Models

This document applies to the following switches:


 QLogic 5800 Switch
 QLogic 5802 Switch
 QLogic 3810 Switch

2 Version and Date

These release notes describe the changes, fixes, known issues, and release details that
apply to QLogic 3810 and QLogic 5800V Series Switch firmware, version 8.0.14.19 that was
released in February, 2016.
If you intend to use Enterprise Fabric Suite to manage QLogic 5800V Series switches with
firmware version 8.0.14.xx, you must use Enterprise Fabric Suite version 8.00.12.07 or
later.
The QLogic 3810 switch can be managed with the CLI or with the QuickTools graphical user
interface. QLogic does not support the use of Enterprise Fabric Suite to manage the QLogic
3810 switch.

3 Changes

This version of the firmware requires Java 8. See Section 4 for bug fixes.

Switch Firmware Version 8.0.14.19 Page 1 of 4


4 Bug Fixes

The following fixes have been made to the firmware between versions 8.0.14.13 and
8.0.14.19 and between QuickTools versions 8.00.14.08 and 8.00.14.10:

PR Number Problem
126657 Fixed the Java exception when connecting to a switch with QuickTools.
126767 Update openssl to fix the FREAK vulnerability (CVE-2015-0204).
126779 Do not export the SNMPv3 users in a configuration backup (Config Backup).
126830 Update openssl to 1.0.1o to fix the Logjam vulnerability.
126879 Fixed the range checking on IPSEC policy priorities.
Fixed Net-SNMP resolving CVE-2015-5621; upgraded OpenSSL to 1.0.1p resolving
126891
CVE-2015-1793.
Fixed SNMP dialog error indicated by the message: Switch does not support
126928
the format for trap address 2.
126939 Updated NTP to 4.2.8p4.
Updated OpenSSL to 1.0.1r with SSLv3 disabled.
126982 Disabled SSH roaming mode resolving CVE-2016-0777 and CVE-2016-0778
126988 Upgraded OpenSSL to 1.0.1r, cURL to 7.47.0, and NPT to 4.2.8p6.
Disallow the addition of or changing of a password with QuickTools when not using
126999
SSL.
127003 Update to allow loading QuickTools in Internet Explorer 11.
127004 Fixed QuickTools port diagnostics hang when the switch is not online.
Properly reenable the Change Password button in the User Accounts dialog, after
127005
clicking Apply.
127006 Fix intermittent ClassNotFoundException when launching QuickTools.
127007 Issue a warning if the firmware version has changed since launching QuickTools.

5 Known Issues

The following table identifies the known issues in firmware version 8.0.14.19 and the
QuickTools 8.00.14.10 web applet.

PR Number Problem
Firmware
You may see sluggish response from the CLI when the switch is in a large fabric
(12 or more switches and/or more than 350 devices), and the fabric is being
15409 discovered. For example, fabric discovery would occur when adding a new switch
to the fabric. Discovering the fabric can take from one to five minutes depending
on zoning size and the number of switches.
When upgrading firmware while in maintenance mode, the message WARNING:
16756 This key is not certified with a trusted signature ... appears. This
message is incorrect and should be ignored.
When running internal port loopbacks on a QLogic 5800V/5802V switch,
intermittent failures may be seen when inter-switch links are present. The
17650
workaround is to put the switch in diagnostic mode, or to remove the inter-switch
links.

Switch Firmware Version 8.0.14.19 Page 2 of 4


PR Number Problem
The switch may have difficulty communicating with the DHCPv6 server with certain
options enabled. The following lines in the server.conf file on the DHCPv6 server
host should be commented out:

# provide VoIP parameter (SIP protocol servers and domain names)


# option sip-server 2000::300,2000::302,2000::303,2000::304
24439 # option sip-domain sip1.example.com,sip2.example.com
# provide NIS information (server addresses and domain name)
# option nis-server 2000::400,2000::401,2000::404,2000::405,2000::405
# option nis-domain nis.example.com
# provide NIS+ information (server addresses and domain name)
# option nis+-server 2000::501,2000::502
# option nis+-domain nisplus.example.com

If QLogic 5800VSeries Switches are configured in a stack with cascading 10G ISLs
(only one ISL between each switch), an Emulex 8G adapter (LP 1200x) running
traffic can experience a timeout when a stack NDCLA or hot reset is performed
109351 using Enterprise Fabric Suite. If the 10G ISL configuration follows QLogic best
practices, the timeout does not occur. For information about best practices and
stacking, see the Stacking section of QLogic 5800V Series Stackable Fibre Channel
Switch Installation Guide, firmware version 8.0).
QuickTools
While running QuickTools, if the IP address of the entry switch is changed, online
10750 help not will open. To access the online help, close the current QuickTools session,
and then reopen QuickTools using the new IP address.
You may see sluggish response from QuickTools when the switch is in a large fabric
(12 or more switches and/or more than 350 devices), and the fabric is being
15438 discovered. For example, fabric discovery would occur when adding a new switch
to the fabric. Discovering the fabric can take from one to five minutes depending
on zoning size and the number of switches.
When a new fabric is added, the Fabric Status bar may incorrectly show a warning
16999 condition related to Nicknames differ. This warning goes away when the fabric is
fully discovered, and nickname conflicts between switches are resolved.
To open the online help in QuickTools on a Mac OS platform, the default browser
18183
must be set to a browser other than the one used to open QuickTools.

6 Additional Information

Read the following document files for more information:


 readme_firmware_8.0.14.19.pdf

Switch Firmware Version 8.0.14.19 Page 3 of 4


7 Trademarks

Accelera, Accelerating Cluster Performance, FastFabric, InfiniCon Systems, InfiniNIC,


InfiniPath, InfiniView, Intelligent NIC, Networking University, NetXen, QLogic, the QLogic
logo, ReadyPath, SANdoctor, SANsurfer, and SilverStorm are registered trademarks of
QLogic Corporation.
To the extent a name or logo does not appear on this list does not constitute a waiver of
any and all intellectual property rights that QLogic Corporation or its subsidiaries has
established in any of its product, feature, or service names or logos. All other brand and
product names are trademarks or registered trademarks of their respective owners.

8 Notices

Information furnished in this document is believed to be accurate and reliable. However,


QLogic Corporation assumes no responsibility for its use, nor for any infringements of
patents or other rights of third parties which may result from its use. QLogic Corporation
reserves the right to change product specifications at any time without notice. Applications
described in this document for any of these products are only for illustrative purposes.
QLogic Corporation makes no representation nor warranty that such applications are
suitable for the specified use without further testing or modification. QLogic Corporation
assumes no responsibility for any errors that may appear in this document.

9 Contacting Support

Please feel free to contact your QLogic approved reseller or QLogic Technical Support at any
phase of integration for assistance. QLogic Technical Support can be reached by the
following methods:
Web: http://support.qlogic.com
E-mail: support@qlogic.com
Go to Top

© Copyright 2016. All rights reserved worldwide. QLogic, the QLogic logo, and the Powered by
QLogic logo are registered trademarks of QLogic Corporation. All other brand and product names
are trademarks or registered trademarks of their respective owners.

Switch Firmware Version 8.0.14.19 Page 4 of 4

Potrebbero piacerti anche