Note: Ensure that the calibration procedure for the governor actuator is performed when

the
governor actuator, the accelerator cable or the controller has been replaced or installed.
The
temperature of the hydraulic oil should be 50 °C (122 °F) prior to the calibration.

illustration 1

g00777652
The above illustration is an example of the display for the 312C. All of the other displays are identical
with
the sales model on the fourth line.
Enter 1. the service mode.

Illustration 2 g00825978
Highlight the second line of the display and use the direction for direction to scroll
through
the display. Scroll through the display until the display shows "CALIBRATION".
2.
Illustration 3 g00790593
Highlight the third line by using the keys for direction. The name of the device will be
shown on the third line. Scroll downward until "STANDBY" is highlighted. Press the
"OK"
key in order to start the calibration procedure. "GOVERNOR-EXE" is displayed on the
third line when the governor actuator is calibrated. Press the "OK" key after confirming
the
display of "GOVERNOR-EXE".
3.

Illustration 4 g00790592
The above illustration shows a display that is temporarily shown when the governor
actuator
is moved to the initial position. Press the "OK" key again when the display shows "SP".
The
calibration procedure has started.
4.
Illustration 5 g00790597
The numerical number that is being displayed in the fourth line will change during the
calibration. This number is related to the process of the calibration. See the following
table
Table 1

Content For The Process

Display Process

STANDBY Prior to calibration

1 Transfer of the initial position of the governor actuator

The initial transfer of the information about the position has been
SP
completed.

3 High idle search

4 Positioning of the high idle

5 Data collection of the intermediate points (9-2) down

6 Low idle search

7 Data acquisition of intermediate points (2-9) up

8 Confirmation of the high idle

9 Confirmation of the setting for the speed dial (down)

10 Confirmation of the setting for the speed dial (up)

11 End processing
Illustration 6 g00790598
6. The above illustration is shown after the governor actuator has completed
the calibration.
Warnings
If the fourth line of the display shows any of the following warnings a failure is present.
See the
following table 2 for a detailed description of the warning displays.
Table 2

Warning Codes

Display Warning Corrective Action

Wire nut is installed too


Wire Pitch X (X loose by X pitch. X can Tighten the accelerator cable by the
is a number from be a positive or displayed pitch. Perform the calibration
0 to 9) negative number. Turn again.
clockwise.

Wire nut is installed too


Wire Pitch X (X tight by X pitch. X can Loosen the accelerator cable by the
is number from be a positive or displayed pitch. Perform the calibration
-9 to 0) negative number. Turn again.
clockwise.

High idle is less than the specified value due


to malfunction of the engine, incorrect
WARNING 01 installation of the governor cable, poor fuel,
Insufficient high idle
etc. After the engine has been inspected for
a malfunction, reinstall the cable and
perform the calibration again.

WARNING 02 Incorrect installation of Reinstall the cable and perform the


cable calibration again.
Low idle is more than the value specified
due to a malfunction in the engine, an
WARNING 03 incorrectly installed governor cable, etc.
Excessive low idle
After the engine has been inspected,
reinstall the cable and perform the
calibration again.

Ensure that the cable is adjusted correctly.


WARNING 04
Excessive hysteresis Reinstall the cable and perform the
calibration again.

High idle is unstable due to a malfunction in


the engine, an incorrect installation of the
WARNING 05
Unstable high idle governor cable, etc. After the engine has
been inspected, reinstall the cable and
perform the calibration again.

The speed for the dial setting is unstable due


to a malfunction in the engine, an
WARNING 06
Unstable dial speed incorrectly installed cable, etc. After the
engine has been inspected, reinstall the
cable and perform the calibration again.

Errors
If the fourth line of the display shows any of the following errors a failure is present.
See the
following table for a detailed description of the error displays.
Table 3

Error Codes For The Governor Actuator

Error Description Of The Error


Corrective Action
Code

ERROR Improper calibration of Stop the calibration of the other device.


01 another device Perform one calibration at a time.

ERROR Improper calibration of Stop the calibration of the other device.


02 another module Perform one calibration at a time.

Perform the troubleshooting procedure that


ERROR Failure of the interlock
will confirm the signal that communicates
03 signal
with the monitor.

ERROR Troubleshoot the confirmation of the speed


Abnormal speed sensor
11 sensor.

ERROR Perform the calibration again. Try to prevent


Engine stop
12 the engine from stopping.

ERROR Load available Reset all operational levers to the neutral


13 position. Perform the calibration again.

Overheating of the coolant or You need to allow the complete cooldown.


ERROR
the hydraulic oil during the Clear the overheating condition. Perform the
14
calibration calibration procedure again.

Pressure decrease in the


ERROR engine oil Clear the abnormal occurrence and perform
15 Check for clogged air the calibration again.
cleaner

ERROR Excessive governor Troubleshoot the confirmation of the


16 movement time governor actuator.

Perform the following procedure when the data for the calibration of the governor