What is a concrete field tests ((temp –slump – air content – cubes – ambient temp ))

What is maximum accepted value for concrete (( 35 C ----ACI 305 ))

What is concrete sampling values for one batching (( 38 cu.m when the quantity
more than 40 cu.m )).

As per the aci when not take concrete sample ((when the quantity of concrete less
than 15 cu.m ))

What is maximum accepted duration for transport and concrete cast time finishes
(( 1.5 hours its mean 90 minute ))

What is the difference between the epoxy and non-shrinkage grout (( non-shrinkage
use for static load and epoxy use under the rotary machine to absorb the 85% of
vibration and the concrete foundation be in well condition in long time.

What is maximum value for compressive strength test for non shrinake or epoxy
grout (( non- shrinkage 34 mpa at 28 days ….epoxy 80 mpa at 7 days.)) .

What is the best type of filling which use under the foundations (( structural fill
A,B,C)).

What is the sampling values for structural fill under foundation (( each 90 sq.m ))