Sei sulla pagina 1di 36

IT T Commercial Water

Goulds Pumps
G&L Series SSH
S & M-Group 316 Stainless Steel End Suction Pumps

www.goulds.com

Engineered for life


A Full Range of Product Features

Superior Materials of Drive Motors: Standard NEMA


Construction: AISI Type 316L design T-frame or JM motors in
stainless steel pump parts for single or three phase.
reduced corrosion and improved
Suction and Discharge
strength and ductility.
Flanges: Mate with ANSI class
Frame Mounted Design: 150 flanges.
Flexibility of installation and driver
Close-Coupled Design:
arrangements.
Compact design saves space and
Back Pull-Out Design: Simpli- simplifies maintenance.
fies maintenance when used with
spacer type coupling.
Cast Iron Power Frame: Rig-
idly supported, grease lubricated
ball bearing assembly.
Mechanical Seal: Standard
John Crane Type 21 mechanical
seal.

GOULDS PUMPS
Commercial Water 2
Performance Coverage, 3500 and 1750 RPM

METERS FEET

600
175 3500 RPM

500
150
TOTAL DYNAMIC HEAD

125 400

100 27SH
24SH
300 28SH
11SH
25SH
75
23SH
200
10SH
50 7SH 22SH
8SH
9SH
100
25 6SH
4SH 5SH

0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200

0 20 40 60 80 100 120 140 160 180 200 220 240 260 m3/hr
CAPACITY – U.S. GPM

METERS FEET

150
1750 RPM

40
125

30 100
TOTAL DYNAMIC HEAD

75
24SH
20 11SH 27SH 28SH
25SH

50
10SH

7SH 8SH 22SH 23SH


10
9SH
25
5SH 6SH
4SH

0 0
0 100 200 300 400 500 600 700 800

0 20 40 60 80 100 120 140 160 m3/hr 180


CAPACITY – U.S. GPM

GOULDS PUMPS
Commercial Water 3
SSH S/M-Group Numbering System

Example Product Code


24 SH 1 Q 1 2 A 0
Mechanical Seals and O-Ring
0 = Pre-engineered standard
For optional mechanical seal modify catalog order no. with seal code listed below.

John Crane Type 21 Mechanical Seal


Seal Part No.
Code Metal Parts
Rotary Stationary Elastomers 180-210 250-360
Frames Frames

0 Viton 316 SS 10K27 10K45


Carbon Sil-Carb
2 EPR 10K19 10K20
5 Sil-Carb Sil-Carb Viton 10K64 10K65

Impeller Option Code


For optional impeller diameters modify catalog order no. with impeller code listed below.
Select optional impeller diameter from pump performance curve.

Impeller Pump Size


Code 9SH 10SH 11SH 4SH 7SH 5SH 8SH 6SH 22SH 23SH 24SH 25SH 27SH 28SH
1 x 2-6 1 x 2-8 1 x 2-10 1½ x 2½-6 1½ x 2½-8 2 x 2½-6 2 x 2½-8 2½ x 3-6 2½ x 3 – 8 3x4–8 1½ x 2½ – 10 2 x 2½ – 10 2½ x 3 – 10 3 x 4 – 10
Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia. Dia.
A 65⁄8 827⁄64 103⁄32 6¾ 81⁄4 67⁄8 8¼ 75⁄16 91⁄16 91⁄16 97⁄8 97⁄8 103⁄8 105⁄8
B 67⁄16 81⁄16 917⁄32 63⁄8 713⁄16 67⁄16 7¾ 71⁄8 8¾ 811⁄16 9½ 9½ 915⁄16 10¼
C 511⁄16 711⁄16 91⁄8 61⁄16 7 513⁄16 7½ 615⁄16 8½ 87⁄16 93⁄16 91⁄8 99⁄16 913⁄16
D 53⁄8 73⁄8 8¾ 55⁄8 6¾ 5½ 73⁄16 611⁄16 8¼ 81⁄16 87⁄8 813⁄16 9¼ 97⁄16
E 71⁄8 55⁄16 67⁄16 51⁄8 67⁄8 63⁄8 77⁄8 711⁄16 89⁄16 83⁄16 8¾ 91⁄16
F 411⁄16 61⁄8 413⁄16 63⁄16 61⁄16 7½ 7½ 8¼ 715⁄16 811⁄16
G 43⁄8 47⁄16 55⁄8 71⁄8 71⁄8 711⁄16
H 43⁄16 4¼ 611⁄16 67⁄8
J 37⁄8 6½ 6½
K 6
L 5½
Motor Enclosure
1 = ODP 5 = TEFC Premium Eff.
2 = TEFC 6 = XP Premium Eff.
3 = Explosion Proof 7 = Wash down
4 = ODP Premium Eff. Frame Options
Motor Voltage Substitute Description
1 = 115/208-230 3 = 230 5 = 208-230/460 7 = 575
2 = 115/230 4 = 230/460 6 = 460 7
/8" Imp. Bore
FRM2
HP Rating, Potencia nominal
C = ½ F = 1.5 J = 5 M = 15 Q = 30 T = 60 11/4" Imp. Bore
FRM3
D = .75 G = 2 K = 7.5 N = 20 R = 40 U = 75
E=1 H =3 L = 10 P = 25 S = 50 V = 100
Driver: Hertz/Pole/RPM
1 = 60/3500/1 3 = 60/1750/1 5 = 50/2900/1
2 = 60/3500/3 4 = 60/1750/3 6 = 50/2900/3
Material
SH = 316L Stainless steel NOTE: Not all combinations of motor, impeller and
Pump Size seal options are available for every pump model.
9=1x2–6 4 = 1½ x 2½ – 6 8 = 2 x 2½ – 8 Please check with G&L on non-cataloged numbers.
10 = 1 x 2 – 8 7 = 1½ x 2½ – 8 6 = 2½ x 3 – 6
11 = 1 x 2 – 10 5 = 2 x 2½ – 6 22 = 2½ x 3 – 8
23 = 3 x 4 – 8 24 = 1½ x 2½ – 10 25 = 2 x 2½ – 10
27 = 2½ x 3 – 10 28 = 3 x 4 – 10

GOULDS PUMPS
Commercial Water 4
Performance Curves – 60 Hz, 3500 RPM

Model SSH / 9SH Optional Impeller


METERS FEET Size 1 x 2-6
RPM 3500 Curve CN0619R00 Impeller Standard
200
60 Code Dia. HP Rating
5' NPSHR – FEET
39
A 65/8" DIA. A 65⁄8" 5
50 49 8'
7
B 6 /16" B 67⁄16 5
150 10' C 511⁄16 3
54
D 53⁄8 3
40 56 EFF%
TOTAL DYNAMIC HEAD (H)

NOTE: Pump will pass a sphere


C 511/16"
to 1⁄8" diameter.
D 53/8"

30 100

20 5 HP

50 3 HP

10

NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 25 50 75 100 125 U.S. GPM 150

0 5 10 15 20 25 30 m3⁄ hr

CAPACITY (Q)

Model SSH / 10SH Optional Impeller


METERS FEET Size 1 x 2-8
RPM 3500 Curve CN0613R00 Impeller Standard
300 Code Dia. HP Rating
90

A 827/64" DIA. A 827⁄64" 10


80 6' NPSHR – FEET
33 B 81⁄16 10
250 B 81/16" 10'
42 14' C 711⁄16 7½
70 18' 22'
D 73⁄8 7½
C 711/16" 47
TOTAL DYNAMIC HEAD (H)

E 71⁄8" 7½
D 73/8"
200 NOTE: Pump will pass a sphere
60
49 to 1⁄8" diameter.

E 71/8" 42 EFF%
50
150

40

30 100

NOTE: Not recommended for operation beyond printed H-Q curve.


20
71/2 HP 10 HP
50
0 25 50 75 100 125 150 175 U.S. GPM 200

0 5 10 15 20 25 30 35 40 m3⁄ hr

CAPACITY (Q)

GOULDS PUMPS
Commercial Water 5
Performance Curves – 60 Hz, 3500 RPM

Model SSH / 11SH Optional Impeller


METERS FEET Size 1 x 2-10
RPM 3500 Curve CN0616R00 Impeller Standard
450 Code Dia. HP Rating
130
NPSHR – FEET
3
400 A 10 /32" DIA. 30 A 103⁄32" 20
120
38 22’ B 917⁄32 15
110 17 43 C 91⁄8 15
350 B 9 /32" 25'
27' D 8¾ 15
100
TOTAL DYNAMIC HEAD (H)

45
C 91/8" NOTE: Pump will pass a sphere
300 29' to 1⁄8" diameter.
90

D 83/4" 43 EFF%
80
250
70

60 200
10 HP
50
150 20 HP
40

30 100
NOTE: Not recommended for operation beyond printed H-Q curve. 15 HP
20
50
0 25 50 75 100 125 150 175 U.S. GPM 200

0 5 10 15 20 25 30 35 40 m3⁄ hr

CAPACITY (Q)

Model SSH / 4SH Size 11/2 x 21/2- 6 Optional Impeller


RPM 3500
METERS FEET
Curve CN0488R01 Impeller Standard
60 Code Dia. HP Rating
5' NPSHR – FEET
3
A 6 /4" DIA. 55
175 59 8'
A 6¾" 10
61
50 3 63 B 63⁄8 7½
B 6 /8" 65
C 61⁄16 7½
150
C 61/16" D 55⁄8 5
TOTAL DYNAMIC HEAD (H)

65 12' E 55⁄16 5
40
125 D 55/8" 63 F 411⁄16 3
E 55/16"
61 EFF% G 43⁄8 3
100 H 43⁄16 2
30
10 HP J 33⁄8 2
F 411/16" NOTE: Pump will pass a sphere
75 G 43/8" to 3⁄16" diameter.
7 / HP
1 2
20
H 43/16"
50 J 37/8" 5 HP

3 HP
10
25 2 HP
NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 50 100 150 200 250 U.S. GPM

0 10 20 30 40 50 60 m3⁄ hr

CAPACITY (Q)

GOULDS PUMPS
Commercial Water 6
Performance Curves – 60 Hz, 3500 RPM

Model SSH / 7SH Size 11/2 x 21/2-8 Optional Impeller


RPM 3500
METERS FEET Curve CN0491R00 Impeller Standard
Code Dia. HP Rating
6' NPSHR – FEET
1
275 A 8 /4" DIA. 40
80 50 A 8¼" 15
250 B 713/16" 55 8' B 713⁄16 15
56 57
70 58 C 7 10
225
59 10' D 6¾ 10
TOTAL DYNAMIC HEAD (H)

60 200 C 7" E 67⁄16 7½


D 63/4" 14' F 61⁄8 7½
175 E 67/16" 59
50 58 NOTE: Pump will pass a sphere
F 61/8" 57 EFF% to 3⁄16" diameter.
150
40 15 HP
125

30 100
10 HP
71⁄2 HP
75
20
50
10
25
NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 25 50 75 100 125 150 175 200 225 250 275 U.S. GPM

0 10 20 30 40 50 60 m3⁄ hr

CAPACITY (Q)

Model SSH / 5SH Size 2 x 21/2-6 Optional Impeller


RPM 3500
METERS FEET Curve CN0494R01 Impeller Standard
Code Dia. HP Rating
60 50
A 67/8" DIA. 6' NPSHR – FEET

175 60
A 67⁄8" 15
10'
B 67/16" 64 B 67⁄16 15
50
66 67 C 513⁄16 10
150 14'
68 D 5½ 10
13
C 5 /16" E 51⁄8 7½
68 19'
TOTAL DYNAMIC HEAD (H)

40
125 67 F 413⁄16 7½
D 51/2"
66 EFF%
G 47⁄16 5
1
E 5 /8" H 4¼ 5
100
30 F 413/16"
NOTE: Pump will pass a sphere
G 47/16" 15 HP to 5⁄32" diameter.
75
20
H 41/4" 10 HP
50
71⁄2 HP
10
25 5 HP
NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 50 100 150 200 250 300 350 400 U.S. GPM

0 20 40 60 80 100 m3⁄ hr

CAPACITY (Q)

GOULDS PUMPS
Commercial Water 7
Performance Curves – 60 Hz, 3500 RPM

Model SSH / 8SH Size 2 x 21/2- 8 Optional Impeller


RPM 3500
METERS FEET Curve CN0497R01 Impeller Standard
Code Dia. HP Rating
8' NPSHR – FEET
90 300
50 60 10'
A 81/4" DIA. 65 A 8¼" 25
80 69 B 7¾ 20
250 71 13' C 7½ 20
B 73/4"
70 C 71/2" 16' D 73⁄16 15
TOTAL DYNAMIC HEAD (H)

3
D 7 /16" E 67⁄8 15
60 200 71 F 63⁄16 10
E 67/8" 21'
69
NOTE: Pump will pass a sphere
50 65 EFF%
to ¼" diameter.
F 63/16"
150
40
25 HP

30 100 10 HP
20 HP
15 HP
20
50
10 NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 50 100 150 200 250 300 350 400 U.S. GPM

0 20 40 60 80 100 m3⁄ hr

CAPACITY (Q)

Model SSH / 6SH Size 21/2 x 3- 6 Optional Impeller


RPM 3500
METERS FEET Curve CN0500R00 Impeller Standard
Code Dia. HP Rating

80 7' NPSHR – FEET


250 A 75⁄16" 25
60
70 8'
B 71⁄8 25
A 75/16" DIA.
65
70
C 615⁄16 20
B 71/8" 10' D 611⁄16 20
200 70
60 C 615/16"
TOTAL DYNAMIC HEAD (H)

68 13' E 63⁄8 15
D 611/16"
F 61⁄16 15
50 E 63/8"
66 15' G 55⁄8 10
150 F 61/16" 20'
65 25' NOTE: Pump will pass a sphere
40 to 5⁄16" diameter.
G 55/8"
63

30 100 60 EFF%

20 25 HP
50 20 HP
15 HP
10 NOTE: Not recommended for operation beyond printed H-Q curve.
10 HP

0 0
0 100 200 300 400 500 600 700 U.S. GPM

0 25 50 75 100 125 150 m3⁄ hr 175

CAPACITY (Q)

GOULDS PUMPS
Commercial Water 8
Performance Curves – 60 Hz, 1750 RPM

Model SSH / 9SH Optional Impeller


FEET Size 1 x 2-6
RPM 1750 Curve CN0620R00 Impeller Standard
50 Code Dia. HP Rating
NPSHR – FEET
A 65/8" DIA. 50 A 65⁄8" ¾
B 67/16" 4'
55 B 67⁄16 ¾
40 5' C 511⁄16 ½
56
6' D 53⁄8 ½
TOTAL DYNAMIC HEAD (H)

8' NOTE: Pump will pass a sphere


C 511/16"
to 1⁄8" diameter.
55 EFF%
3
30 D 5 /8"

20 3
⁄4 HP

1
⁄2 HP

10

NOTE: Not recommended for operation beyond printed H-Q curve.

0
0 10 20 30 40 50 60 70 U.S. GPM 80
CAPACITY (Q)

Model SSH / 10SH Optional Impeller


FEET Size 1 x 2-8
RPM 1750 Curve CN0614R00 Impeller Standard
70 Code Dia. HP Rating
A 827/64" DIA. 4' NPSHR – FEET
5'
B 81/16" 42 A 827⁄64" 1½
60 B 81⁄16 1½
6' 47
C 711/16" 8' C 711⁄16 1
D 73⁄8 ¾
50 49 EFF% E 71⁄8 ¾
TOTAL DYNAMIC HEAD (H)

D 73/8"
NOTE: Pump will pass a sphere
E 71/8" to 1⁄8" diameter.
40
11⁄2 HP

30 3
⁄4 HP 1 HP

20

10
NOTE: Not recommended for operation beyond printed H-Q curve.

0
0 10 20 30 40 50 60 70 U.S. GPM 80
CAPACITY (Q)

GOULDS PUMPS
Commercial Water 9
Performance Curves – 60 Hz, 1750 RPM

Model SSH / 11SH Optional Impeller


FEET Size 1 x 2-10
RPM 1750 Curve CN0617R00 Impeller Standard
120 Code Dia. HP Rating
NPSHR – FEET
36 A 103⁄32" 3
38
8’
3
100 A 10 /32" 12’ 14' B 917⁄32 3
C 91⁄8 2
43 17'
D 8¾ 2
B 917/32"
TOTAL DYNAMIC HEAD (H)

NOTE: Pump will pass a sphere


80 C 91/8" 45
to 1⁄8" diameter.
43 EFF%

D 83/4"
60

1 HP
40 3 HP

2 HP
20

NOTE: Not recommended for operation beyond printed H-Q curve.

0
0 25 50 75 U.S. GPM 100
CAPACITY (Q)

Model SSH / 4SH Size 11/2 x 21/2- 6 Optional Impeller


RPM 1750
METERS FEET Impeller Standard
Curve CN0489R01
Code Dia. HP Rating
15
4' NPSHR – FEET
3
A 6 /4" DIA. 54
59 6' A 6¾" 1
60
61 B 63⁄8 1
40 B 63/8" 62
C 61⁄16 1
TOTAL DYNAMIC HEAD (H)

C 61/16" D 55⁄8 ¾
62 8' E 55⁄16 ¾
10
D 55/8" 61 F 411⁄16 ½
30
60 EFF% G 43⁄8 ½
E 55/16"
H 43⁄16 ½
J 33⁄8 ½
11
20 F 4 3 /16" NOTE: Pump will pass a sphere
G 4 /8" 1 HP to 3⁄16" diameter.
5 H 43/16"

J 37/8" 3 ⁄4 HP

10 1 ⁄2 HP

NOTE: Not recommended for operation beyond printed H-Q curve.


i
0 0
0 20 40 60 80 100 120 U.S. GPM

0 5 10 15 20 25 30 m3⁄ hr

CAPACITY (Q)

GOULDS PUMPS
Commercial Water 10
Performance Curves – 60 Hz, 1750 RPM

Model SSH / 7SH Size 11/2 x 21/2-8 Optional Impeller


RPM 1750
METERS FEET
Curve CN0492R00 Impeller Standard
Code Dia. HP Rating
6' NPSHR – FEET
A 81/4" DIA. 38
20 48 A 8¼" 2
B 713/16" 53 8' B 713⁄16 2
60 54 55
56 C 7 1½
D 6¾ 1½
57 10'
C 7" E 67⁄16 1
15
TOTAL DYNAMIC HEAD (H)

3
D 6 /4" 13' F 61⁄8 1
E 67/16" 57 NOTE: Pump will pass a sphere
40 F 61/8" 56
55 EFF% to 3⁄16" diameter.
2 HP
10

11⁄2 HP

20 1 HP
5

NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 20 40 60 80 100 120 U.S. GPM

0 5 10 15 20 25 30 m3⁄ hr

CAPACITY (Q)

Model SSH / 5SH Size 2 x 21/2-6 Optional Impeller


RPM 1750
METERS FEET
Curve CN0495R00 Impeller Standard
Code Dia. HP Rating
A 67/8" DIA. 48
4' NPSHR – FEET

7
58 A 67⁄8" 2
40 B 6 /16"
63 7' B 67⁄16 2
65 66 C 513⁄16 1½
67 9' D 5½ 1½
TOTAL DYNAMIC HEAD (H)

10 C 513/16"
E 51⁄8 1
D 51/2" 67 12'
30 F 413⁄16 1
66
E 51/8" 65 EFF% G 47⁄16 ¾
H 4¼ ¾
F 413/16"
2 HP NOTE: Pump will pass a sphere
G 47/16"
20 to 5⁄32" diameter.

5 H 41/4" 11⁄2 HP

1 HP
10 3 ⁄4 HP

NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 40 80 120 160 200 U.S. GPM

0 10 20 30 40 50 m3⁄ hr

CAPACITY (Q)

GOULDS PUMPS
Commercial Water 11
Performance Curves – 60 Hz, 1750 RPM

Model SSH / 8SH Size 2 x 21/2-8 Optional Impeller


RPM 1750
METERS FEET
Curve CN0498R01 Impeller Standard
Code Dia. HP Rating
5' NPSHR – FEET
20 A 81/4" DIA. 48 58 67
B 73/4" 63
7' 69 A 8¼" 3
60 C 71/2"
B 7¾ 3
D 73/16" 9' C 7½ 2
7
50 E 6 /8" 11' D 73⁄16 2
15
69 E 67⁄8 1½
TOTAL DYNAMIC HEAD (H)

F 63/16" 67 EFF% F 63⁄16 1½


40 NOTE: Pump will pass a sphere
3 HP
to 5⁄32" diameter.
10
30

11/2 HP 2 HP
20
5

10
NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 40 80 120 160 200 U.S. GPM

0 10 20 30 40 50 m3⁄ hr

CAPACITY (Q)

Model SSH / 6SH Size 21/2 x 3-6 Optional Impeller


METERS FEET RPM 1750
Curve CN0502R00 Impeller Standard
Code Dia. HP Rating
20
4' NPSHR – FEET
60 A 75⁄16" 3
57
B 71⁄8 3
A 75/16" DIA. 5'
62 C 615⁄16 3
67
15 50 B 71/8" 7' D 611⁄16 3
15
67
C 6 /16" E 63⁄8 2
TOTAL DYNAMIC HEAD (H)

65 9'
D 611/16" F 61⁄16 2
40 E 6 /8" 3
G 55⁄8 1½
63 11'
F 61/16" 15'
19' NOTE: Pump will pass a sphere
62
10 to 5⁄16" diameter.
30 G 55/8"
60

57 EFF%
20
5
3 HP

10 2 HP
NOTE: Not recommended for operation beyond printed H-Q curve.
11/2 HP

0 0
0 100 200 300 U.S. GPM 400

0 25 50 75 m3⁄ hr
CAPACITY (Q)

GOULDS PUMPS
Commercial Water 12
Performance Curves – 50 Hz, 2900 RPM

Model SSH / 9SH Optional Impeller


FEET Size 1 x 2-6
RPM 2900 Curve CN0621R00 Impeller Standard
120 Code Dia. HP Rating
A 65/8" DIA. 40 50

B 67/16" 4'
A 65⁄8" 3
100 55 5' NPSHR – FEET
B 67⁄16 3
56
C 511⁄16 2
7' D 53⁄8 2
TOTAL DYNAMIC HEAD (H)

C 511/16"
55 EFF% NOTE: Pump will pass a sphere
80 D 53/8" to 1⁄8" diameter.

60

3 HP
40
1 2 HP
/2 HP

20

NOTE: Not recommended for operation beyond printed H-Q curve.

0
0 20 40 60 80 100 U.S. GPM 120

CAPACITY (Q)

Model SSH / 10SH Optional Impeller


FEET Size 1 x 2-8
RPM 2900 Curve CN0615R00 Impeller Standard
250 Code Dia. HP Rating

A 83⁄8" 5
5' NPSHR – FEET B 81⁄16 5
200 C 75⁄8 5
A 83/8" DIA. 7' 42
D 71⁄8 5
47
TOTAL DYNAMIC HEAD (H)

B 81/16" E 71⁄8 3
9’
C 75/8" 12’ 49 EFF% NOTE: Pump will pass a sphere
150 to 1⁄8" diameter.

D 75/16"

E 71/8"

100

5 HP
3 HP
50

NOTE: Not recommended for operation beyond printed H-Q curve.

0
0 25 50 75 100 125 U.S. GPM 150

CAPACITY (Q)

GOULDS PUMPS
Commercial Water 13
Performance Curves – 50 Hz, 2900 RPM

Model SSH / 11SH Optional Impeller


FEET Size 1 x 2-10
RPM 2900 Curve CN0618R00 Impeller Standard
300 Code Dia. HP Rating

30 NPSHR – FEET
A 103/32" DIA. A 103⁄32" 15
8’ 38 18'
14’ B 917⁄32 10
250 C 91⁄8 10
B 917/32" 20' D 8¾ 7½
TOTAL DYNAMIC HEAD (H)

43
NOTE: Pump will pass a sphere
C 91/8" 45 to 1⁄8" diameter.
43 EFF%
200
D 83/4"

150

10 HP

100
71/2 HP

NOTE: Not recommended for operation beyond printed H-Q curve.

50
0 25 50 75 100 125 150 U.S. GPM 175
CAPACITY (Q)

Model SSH / 4SH Size 11/2 x 21/2-6 Optional Impeller


RPM 2900
METERS FEET
Curve CN0490R01 Impeller Standard
Code Dia. HP Rating
40 4' NPSHR – FEET

A 63/4" DIA. 55
120 60 6'
A 6¾" 5
61
62 B 63⁄8 5
B 63/8" 64
C 61⁄16 5
30 100 C 61/16" D 55⁄8 3
64 8'
TOTAL DYNAMIC HEAD (H)

E 55⁄16 3
D 55/8" 62 F 411⁄16 2
80 61 EFF%
5
E 5 /16" G 43⁄8 2
H 43⁄16 1½
20 J 33⁄8 1
60
F 411/16" 5 HP NOTE: Pump will pass a sphere
G 43/8" to 3⁄16" diameter.
H 43/16"
40 J 37/8" 3 HP
10

20 2 HP
NOTE: Not recommended for operation beyond printed H-Q curve. 1 HP

0 0
0 40 80 120 160 200 U.S. GPM

0 10 20 30 40 50 m3⁄ hr
CAPACITY (Q)

GOULDS PUMPS
Commercial Water 14
Performance Curves – 50 Hz, 2900 RPM

Model SSH / 7SH Size 11/2 x 21/2- 8 Optional Impeller


METERS FEET RPM 2900
Curve CN0493R00 Impeller Standard
Code Dia. HP Rating
60 200
6' NPSHR – FEET
A 81/4" DIA. 39
49 A 8¼" 10
B 713/16" 54 8'
55 B 713⁄16 7½
50 56
160 57 C 7 7½
58 13' D 6¾ 7½
TOTAL DYNAMIC HEAD (H)

C 7" E 67⁄16 5
40 D 63/4" 17'
F 61⁄8 5
120 E 67/16" 58
57 NOTE: Pump will pass a sphere
F 61/8" 56 EFF%
to 3⁄16" diameter.
30 10 HP

80 71/2 HP

20
5 HP

40
10

NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 40 80 120 160 200 U.S. GPM

0 10 20 30 40 50 m3⁄ hr

CAPACITY (Q)

Model SSH / 5SH Size 2 x 21/2-6 Optional Impeller,


METERS FEET RPM 2900
Curve CN0496R01 Impeller Standard
Code Dia. HP Rating
40 49
A 67/8" DIA. 5' NPSHR – FEET

120 59 A 67⁄8" 10
B 67/16" 64 7' B 67⁄16 7½
66 67 C 513⁄16 7½
30 100 68 10' D 5½ 5
TOTAL DYNAMIC HEAD (H)

13
C 5 /16" E 51⁄8 5
68 14'
D 51/2" 67 F 413⁄16 3
80 66 EFF% G 47⁄16 3
E 51/8" H 4¼ 3
20 F 413/16" 10 HP
NOTE: Pump will pass a sphere
60 to 5⁄32" diameter.
7
G 4 /16"
71/2 HP
H 41/4"
40 5 HP
10
3 HP
20
NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 40 80 120 160 200 240 280 320 360 U.S. GPM

0 10 20 30 40 50 60 70 80 m3⁄ hr
CAPACITY (Q)

GOULDS PUMPS
Commercial Water 15
Performance Curves – 50 Hz, 2900 RPM

Model SSH / 8SH Size 2 x 21/2-8 Optional Impeller


METERS FEET RPM 2900
Curve CN0499R01 Impeller Standard
Code Dia. HP Rating
6' NPSHR – FEET
A 81/4" DIA.

B 73/4" 49 59 64 7' A 8¼" 15


50 1
160 C 7 /2" 68 B 7¾ 15
D 73/16" 70 9' C 7½ 10
E 67/8" 13' D 73⁄16 10
71
40 E 67⁄8 7½
120 F 63/16" 70 F 63⁄16 7½
TOTAL DYNAMIC HEAD (H)

16'
68 NOTE: Pump will pass a sphere
30 to 5⁄32" diameter.
64 EFF%

80 15 HP

20
10 HP

40 71/2 HP
10
NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 40 80 120 160 200 240 280 320 360 U.S. GPM

0 10 20 30 40 50 60 70 80 m3⁄ hr

CAPACITY (Q)

Model SSH / 6SH Size 21/2 x 3-6 Optional Impeller


METERS FEET RPM 2900
Curve CN0501R00 Impeller Standard
Code Dia. HP Rating

6' NPSHR – FEET


175
A 75⁄16" 15
50 58
B 71⁄8 15
A 75/16" DIA. 7'
150 64
69
C 615⁄16 15
B 71/8" 69 8' D 611⁄16 10
TOTAL DYNAMIC HEAD (H)

C 615/16"
40 67 E 63⁄8 10
125 D 611/16" 11'
F 61⁄16 7½
E 63/8"
65 13' G 55⁄8 7½
F 61/16" 17'
30 100 64 21' NOTE: Pump will pass a sphere
5
to 5⁄16" diameter.
G 5 /8"
62
75
20 58 EFF%

50
15 HP
10
10 HP
25
NOTE: Not recommended for operation beyond printed H-Q curve. 71/2 HP

0 0
0 100 200 300 400 500 600 U.S. GPM

0 25 50 75 100 125 m3⁄ hr

CAPACITY (Q)

GOULDS PUMPS
Commercial Water 16
Performance Curves – 60 Hz, 3500 RPM

Model SSH – 24SH / Size 11/2 x 21/2-10 Optional Impeller


RPM 3500
METERS FEET
Curve CN0503R00 Impeller Standard
450 Code Dia. HP Rating
130 A 97/8" DIA. 6' NPSHR – FEET
400 50% EFF
120 8'
55 A 97⁄8" 30
1
B 9 /2" 57 10'
110 59 B 9½ 30
350
C 93/16" 60
100 C 93⁄16 25
D 87/8" 12'
59 D 87⁄8 25
300 E 89/16"
TOTAL DYNAMIC HEAD (H)

90
F 81/4" 55 E 89⁄16 20
80 F 8¼ 20
250
70 30 NOTE: Pump will pass a sphere
HP
200 25
to 5⁄16" diameter.
60 HP

50 20
HP
150
40

30 100

20
50
10 NOTE: Not recommended for operation beyond printed H-Q curve.

0
0 50 100 150 200 250 300 U.S. GPM

0 20 40 60 m3⁄hr
CAPACITY (Q)

Model SSH – 25SH / Size 2 x 21/2-10 Optional Impeller


METERS FEET
RPM 3500
Curve CN0506R00 Impeller Standard
450
Code Dia. HP Rating
130 A 97/8" DIA. 7' NPSHR – FEET
400 55% EFF
120 60 9'
B 91/2" 62 A 97⁄8" 50
63
110 11'
350 C 91/8" 64 B 9½ 40
100 D 813/16" 20' C 91⁄8 40
TOTAL DYNAMIC HEAD (H)

64
90 300 D 813⁄16 30
63
E 83/16" E 83⁄16 30
80 F 715/16" 50
250 HP F 715⁄16 25
G 711/16"
70 G 711⁄16 25
40
HP
60 200 NOTE: Pump will pass a sphere
30 to ½" diameter.
50 HP
150 25
40 HP

30 100

20
50
10 NOTE: Not recommended for operation beyond printed H-Q curve.

0
0 50 100 150 200 250 300 350 400 450 500 U.S. GPM

0 20 40 60 80 100 m3⁄hr
CAPACITY (Q)

GOULDS PUMPS
Commercial Water 17
Performance Curves – 60 Hz, 3500 RPM

Model SSH – 22SH / Size 21/2 x 3-8 Optional Impeller


RPM 3500
METERS FEET Curve CN0509R00
Impeller Standard
7' NPSHR – FEET (PIES) Code Dia. HP Rating
40% EFF 8'
350 50
60
A 91/16" DIA. 10'
65 12'
100 3
325 B 8 /4" A 91⁄16" 60
68 15'
C 81/2" 20' B 8¾ 50
90 300 25'
C 8½ 50
D 81/4" 70 68
275 D 8¼ 40
30'
TOTAL DYNAMIC HEAD (H)

80 65
7 E 77⁄8 40
250 E 7 /8" 60
71 F 7½ 30
70 225 F 7 /2"
1
G 71⁄8 25
11
200 G 7 /8" 1 H 6 ⁄16 20
60
11
J 6½ 20
175 H 6 /16" 60
50 J 61/2" NOTE: Pump will pass a sphere
HP
150 to 19⁄32" diameter.

50
15

HP
40
125 HP

40
30 100

HP
30
75 25 HP
20 NOTE: Not recommended for operation beyond printed H-Q curve. HP
20 HP
50
0 100 200 300 400 500 600 700 800 U.S. GPM

0 20 40 60 80 100 120 140 160 180 m3⁄hr


CAPACITY (Q)

Model SSH – 27SH / Size 21/2 x 3-10 Optional Impeller


RPM 3500
METERS FEET Curve CN0512R00
Impeller Standard
Code Dia. HP Rating
600
175 7' NPSHR – FEET
550 A 103⁄8" 100
45% EFF 8'
55 10' B 915⁄16 75
60
150 500 12'
65 9
A 10 /8" DIA.3
15' C 9 ⁄16 75
69
450 B 915/16" 20' D 9¼ 60
30'
TOTAL DYNAMIC HEAD (H)

125 9 70 69 E 8¾ 50
400 C 9 /16"
D 91/4" 10
NOTE: Pump will pass a sphere
350 0H to 19⁄32" diameter.
100 E 83/4" P

300 75
40 65 HP
250 HP
75

200 60
HP
50 50
150 HP

100
25
50
NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 100 200 300 400 500 600 700 800 U.S. GPM

0 20 40 60 80 100 120 140 160 180 m3⁄hr


CAPACITY (Q)

GOULDS PUMPS
Commercial Water 18
Performance Curves – 60 Hz, 3500 RPM

Model SSH – 23SH / Size 3 x 4-8 NOTE: Not recommended for operation beyond printed H-Q curve.
Optional Impeller
RPM 3500
METERS FEET Curve CN0515R00
Impeller Standard
10' Code Dia. HP Rating
50% EFF
12' NPSHR – FEET
350 60
A 91/16" DIA. 14'
100 70
325 17' A 91⁄16" 75
B 811/16" 75
77 20' B 811⁄16 75
300 C 8 /16" 7
90 78
78 25' C 87⁄16 60
275 D 81/16" 77 D 81⁄16 50
TOTAL DYNAMIC HEAD (H)

30'
80
250 E 711/16" 10 E 711⁄16 50
75 0
HP
70 1 F 7½ 40
225 F 7 /2"
G 71⁄8 40
G 71/8"
200 75
60 HP H 67⁄8 30
H 67/8"
175 J 6½ 25
50 J 61/2"
60 K 6 20
150 HP
70 L 5½ 15
40 50
125 K 6" NOTE: Pump will pass a sphere
HP
to ¾" diameter.
30 100 40
L 51⁄2" HP
75 3
20 15 25 0 HP
HP H
50 20 HP P
0 200 400 600 800 1000 1200 1400 1600 U.S. GPM

0 40 80 120 160 200 240 280 320 360 m3⁄hr


CAPACITY (Q)

Model SSH – 28SH / Size 3 x 4-10 Optional Impeller


RPM 3500
METERS FEET Curve CN0518R00
Impeller Standard
Code Dia. HP Rating
600
175
550 C 913⁄16" 100
NPSHR – FEET D 97⁄16 100
150 500 8'
45% EFF 10' E 91⁄16 75
55 12'
450 65
70 14' F 811⁄16 75
73
C 913/16" DIA. 17'
TOTAL DYNAMIC HEAD (H)

125 400 75 20' NOTE: Pump will pass a sphere


76 25' to ¾" diameter.
D 97/16"
76
350 E 91/16" 75 30'
100 73
F 811/16"
300

250 10
75 60 0H
HP P
200 75
HP
50
150

100
25
50
NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 200 400 600 800 1000 1200 1400 1600 U.S. GPM

0 40 80 120 160 200 240 280 320 360 m3⁄hr


CAPACITY (Q)

GOULDS PUMPS
Commercial Water 19
Performance Curves – 60 Hz, 1750 RPM

Model SSH – 24SH / Size 11/2 x 21/2-10 Optional Impeller


METERS FEET RPM 1750
Curve CN0505R00 Impeller Standard
110 Code Dia. HP Rating
7
A 9 /8" DIA. 3' NPSHR – FEET
100 45% EFF
30
50 A 97⁄8" 5
B 91/2" 52 4'
90 54
C 93/16" B 9½ 5
56
25 7
80 D 8 /8" 5' C 93⁄16 3
54
TOTAL DYNAMIC HEAD (H)

E 89/16" 52 D 87⁄8 3
70 F 81/4" 50
20 E 89⁄16 3
60 F 8¼ 2
NOTE: Pump will pass a sphere
15 50 3H
P to 5⁄16" diameter.
40
2H
P
10
30

20
5
10
NOTE: Not recommended for operation beyond printed H-Q curve.

0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 U.S. GPM

0 5 10 15 20 25 30 m3⁄hr
CAPACITY (Q)

Model SSH – 25SH / Size 2 x 21/2-10 Optional Impeller


METERS FEET RPM 1750
Curve CN0508R00 Impeller Standard
110 Code Dia. HP Rating
7
A 9 /8" DIA. 4' NPSHR – FEET
100 50% EFF
30
55 57
B 91/2" A 97⁄8" 7½
58
90 5'
C 9 /8" 1 59 B 9½ 5
25 13
80 D 8 /16" 8' C 91⁄8 5
59
TOTAL DYNAMIC HEAD (H)

58 7.5
HP
D 813⁄16 5
70 E 83/16"
20 15
F 7 /16" E 83⁄16 3
60 G 711/16" F 715⁄16 3
11
5H G 7 ⁄16 3
15 50 P
NOTE: Pump will pass a sphere
40 to ½" diameter.
10
30 3H
P

20
5
10
NOTE: Not recommended for operation beyond printed H-Q curve.

0
0 20 40 60 80 100 120 140 160 180 200 220 240 U.S. GPM

0 5 10 15 20 25 30 35 40 45 50 55 m3⁄hr
CAPACITY (Q)

GOULDS PUMPS
Commercial Water 20
Performance Curves – 60 Hz, 1725 RPM

Model SSH – 22SH / Size 21/2 x 3-8 Optional Impeller


RPM 1750
METERS FEET Curve CN0511R00
Impeller Standard
Code Dia. HP Rating
120
35
110 A 91⁄16" 7½
C 8½ 7½
30 100
D 8¼ 5
NPSHR – FEET
90 40% EFF
5'
E 77⁄8 5
50
TOTAL DYNAMIC HEAD (H)

55 6'
25 80 A 9 /16" DIA.
1 G 71⁄8 3
60 62 8'
1
C 8 /2" H 611⁄16 3
70 64 10'
20 D 81/4" NOTE: Pump will pass a
62
60 E 7 /8" 7
sphere to 19⁄32" diameter.
60 15'
55
15 50
G 71/8" 50
40 H 611/16"
10 2
HP
30
71
/2
HP
20
5 5
HP
10
NOTE: Not recommended for operation beyond printed H-Q curve. 3
HP
0 0
0 50 100 150 200 250 300 350 400 450 U.S. GPM

0 10 20 30 40 50 60 70 80 90 100 m3⁄hr
CAPACITY (Q)

Model SSH – 27SH / Size 21/2 x 3-10 Optional Impeller


RPM 1750
METERS FEET Curve CN0514R00
Impeller Standard
Code Dia. HP Rating
50% EFF NPSHR – FEET
120 55 60
63 5'
3 A 103/8" DIA. 66
110 7' A 103⁄8" 15
68
B 915/16"
100
10' B 915⁄16 10
3 68
9
C 99/16" 15' C 9 ⁄16 10
66
90 D 9¼ 7½
D 91/4"
TOTAL DYNAMIC HEAD (H)

20'
2 63
E 8¾ 7½
80
E 83/4"
60
NOTE: Pump will pass a sphere
70
2 to 19⁄32" diameter.
15

55
HP

60
5
HP

15 50
10
HP

40
7
1 2
/

10
H

30
P

20
5
10
NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 50 100 150 200 250 300 350 400 450 U.S. GPM

0 10 20 30 40 50 60 70 80 90 100 m3⁄hr
CAPACITY (Q)

GOULDS PUMPS
Commercial Water 21
Performance Curves – 60 Hz, 1725 RPM

Model SSH – 23SH / Size 3 x 4-8 NOTE: Not recommended for operation beyond printed H-Q curve.
Optional Impeller
RPM 1750
METERS FEET Curve CN0517R00
Impeller Standard
Code Dia. HP Rating
120
35
110 A 91⁄16" 10
100 C 87⁄16 7½
30
D 81⁄16 7½
90 45% EFF
55 F 7½ 5
65 5' NPSHR – FEET
TOTAL DYNAMIC HEAD (H)

25 1
80 A 9 /16" DIA. 68 G 71⁄8 5
71 6'
8' J 6½ 3
70 C 87/16" 73
10'
20 1 74 15'
NOTE: Pump will pass a sphere
D 8 /16"
60 to ½" diameter.
73
F 71/2" 71
15 50
G 71/8" 68
65
40
J 61/2" 55
10
30
10
3 HP
20 HP 71
/2 H
5 P
10 5H
P

0 0
0 100 200 300 400 500 600 700 800 900 U.S. GPM

0 20 40 60 80 100 120 140 160 180 200 m3⁄hr


CAPACITY (Q)

Model SSH – 28SH / Size 3 x 4-10 Optional Impeller


RPM 1750
METERS FEET Curve CN0520R00
Impeller Standard
Code Dia. HP Rating

40 130
45% EFF A 105⁄8" 20
55 7' NPSHR – FEET
65 B 10¼ 15
120 A 105/8" DIA. 70
35
8'
C 913⁄16 15
110 B 101/4" 73
10' D 97⁄16 15
TOTAL DYNAMIC HEAD (H)

30 100 C 913/16" 74 15' NOTE: Pump will pass a sphere


7 73 20' to ¾" diameter.
90 D 9 /16"
70 30'
25
80
65
70 10
20 H
P
60 20
H
P
15 50
15
H
P
40
10
30
NOTE: Not recommended for operation beyond printed H-Q curve.

20
0 100 200 300 400 500 600 700 800 900 U.S. GPM

0 20 40 60 80 100 120 140 160 180 200 m3⁄hr


CAPACITY (Q)

GOULDS PUMPS
Commercial Water 22
Performance Curves – 50 Hz, 2900 RPM

Model SSH – 24SH / Size 11/2 x 21/2-10 Optional Impeller


RPM 2900
METERS FEET
Curve CN0504R00
Impeller Standard
300 Code Dia. HP Rating
90
7
A 9 /8" DIA. 3' NPSHR – FEET

48% EFF
80 6'
53 55 A 97⁄8" 20
250 B 91/2" 8'
57
C 93/16" B 9½ 15
70 58
D 87/8" 10' C 93⁄16 15
57
TOTAL DYNAMIC HEAD (H)

9
200 E 8 /16" 55 D 87⁄8 15
60 53 20
F 81/4" HP E 89⁄16 10
F 8¼ 10
50
150 NOTE: Pump will pass a sphere
to ½" diameter.
40 15
HP

30 100 10
HP

20
50
10
NOTE: Not recommended for operation beyond printed H-Q curve.

0
0 20 40 60 80 100 120 140 160 180 200 220 240 U.S. GPM

0 10 20 30 40 50 m3⁄hr
CAPACITY (Q)

Model SSH – 25SH / Size 2 x 21/2-10 Optional Impeller


RPM 2900
METERS FEET
Curve CN0507R00
Impeller Standard
90 300 Code Dia. HP Rating
A 97/8" DIA. 6' NPSHR – FEET
53% EFF
80 58 60 8'
B 91/2" A 97⁄8" 30
250 61
10'
1
C 9 /8" 62 B 9½ 25
70
D 813/16" 17' C 91⁄8 20
62
TOTAL DYNAMIC HEAD (H)

200 61 D 813⁄16 20
60 E 83/16"
F 715/16" 30 E 83⁄16 15
HP
50 G 711/16" F 715⁄16 15
25
150 HP 11
G 7 ⁄16 15
40 NOTE: Pump will pass a sphere
20
HP to 5⁄16" diameter.
100 15
30 HP

20
50
10
NOTE: Not recommended for operation beyond printed H-Q curve.

0 40 80 120 160 200 240 280 320 360 400 U.S. GPM
0

0 20 40 60 80 m3⁄hr
CAPACITY (Q)

GOULDS PUMPS
Commercial Water 23
Performance Curves – 50 Hz, 2900 RPM

Model SSH – 22SH / Size 21/2 x 3-8 Optional Impeller


METERS FEET RPM 2900
Curve CN0510R00
250 Impeller Standard
40% EFF 6' NPSHR – FEET Code Dia. HP Rating
50 7'
70 60 8'
A 91/16" DIA.
10'
225 B 83/4"
C 81/2" 65 A 91⁄16" 40
12' 15'
60
200 B 8¾ 30
D 81/4" 67 65 18'
C 8½ 30
60 20'
175 E 77/8" D 8¼ 25
50
TOTAL DYNAMIC HEAD (H)

E 77⁄8 20
68
F 71/2"
150 F 7½ 20
40 G 71/8" 40 G 71⁄8 15
HP
11
125 H 611/16" H 6 ⁄16 15
J 61/2" J 6½ 15
30 30
100 50 HP NOTE: Pump will pass a sphere
to 19⁄32" diameter.
10

25
HP

75 HP
20
20
HP
50 15
10 HP
NOTE: Not recommended for operation beyond printed H-Q curve.

0
0 100 200 300 400 500 600 U.S. GPM 700

0 20 40 60 80 100 120 140 m3⁄hr


CAPACITY (Q)

Model SSH – 27SH / Size 21/2 x 3-10 Optional Impeller


METERS FEET RPM 2900
Curve CN0513R00
400 Impeller Standard
Code Dia. HP Rating
NPSHR – FEET
45% EFF 6'
350 55 8'
60
100 10' A 103⁄8" 50
A 103/8" DIA. 65
12' 15
68 B 9 ⁄16 40
300 B 915/16" 15'
68
20' C 9 9⁄16 40
C 99/16" 69
D 9¼ 30
TOTAL DYNAMIC HEAD (H)

65
75 250 D 91/4" E 8¾ 30
E 83/4" 50 NOTE: Pump will pass a sphere
HP
200 to 19⁄32" diameter.
25
HP 40
50 HP
150

30
HP
100
25

50

NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 100 200 300 400 500 600 U.S. GPM 700

0 20 40 60 80 100 120 140 m3⁄hr


CAPACITY (Q)

GOULDS PUMPS
Commercial Water 24
Performance Curves – 50 Hz, 2900 RPM

Model SSH – 23SH / Size 3 x 4-8 Optional Impeller


METERS FEET RPM 2900
Curve CN0516R00
250 Impeller Standard
50% EFF 9' Code Dia. HP Rating
70 60 10' NPSHR – FEET
A 91/16" DIA.

225 12'
70
B 811/16" 72 A 91⁄16" 50
15' B 811⁄16 40
60 C 87/16" 74
200
76 C 87⁄16 40
20'
D 81/16" 76 D 81⁄16 30
74
TOTAL DYNAMIC HEAD (H)

50 175 E 711⁄16 30
E 711/16"
72 F 7½ 25
F 71/2"
150 G 71⁄8 20
50
G 71/8" HP H 67⁄8 20
40
7 J 6½ 15
125 H 6 /8"
40
HP NOTE: Pump will pass a sphere
J 61/2" to ½" diameter.
70
30
100
30
HP
20 75 25
HP
20
HP
50
15
10 HP
NOTE: Not recommended for operation beyond printed H-Q curve.

0
0 200 400 600 800 1000 1200 U.S. GPM 1400

0 40 80 120 160 200 240 280 m3⁄hr


CAPACITY (Q)

Model SSH – 28SH / Size 3 x 4-10 Optional Impeller


METERS FEET RPM 2900
Curve CN0519R00
400 Impeller Standard
Code Dia. HP Rating

350 NPSHR – FEET (PIES)


C 913⁄16" 60
100 8'
50% EFF 9' D 97⁄16 50
60 10'
300 65
12' 1
70 E 9 ⁄16 50
C 913/16" DIA. 14'
73
F 811⁄16 40
TOTAL DYNAMIC HEAD (H)

D 97/16" 75 17'
75 250 75
20'
NOTE: Pump will pass a sphere
E 91/16"
73 to ¾" diameter.
F 811/16"
200
30 60
HP HP
50
150 50
40 HP
HP

100
25

50

NOTE: Not recommended for operation beyond printed H-Q curve.

0 0
0 200 400 600 800 1000 1200 U.S. GPM 1400

0 40 80 120 160 200 240 280 m3⁄hr


CAPACITY (Q)

GOULDS PUMPS
Commercial Water 25
SSH Close Coupled – Materials of Construction SSH Frame Mounted – Materials of Construction

100 101 178 108 370 100 101 513 370 184 383 108 228

412A
103 513
134
184
370C
333A
412A 383

126
199 422 408 412F 126 371 103 199 422 408 178 412F 370B 123 168 112 382 122
Item No., Description Materials Item No., Description Materials

100 Casing 100 Casing


101 Impeller 101 Impeller
316L SS 316L SS
103 Wear ring 103 Wear ring
184 Seal housing 184 Seal housing
126 Shaft sleeve 316 SS 126 Shaft sleeve 316 SS
422 Impeller stud Steel 178 Impeller key Carbon steel
Impeller key Carbon steel 422 Impeller Stud
178
199 Impeller washer 316 SS
199 Impeller washer 316 SS 370 Casing bolt with nut 316L SS
Casing bolt with nut (casing to adapter) 408 Drain plug – 3⁄8 NPT
316L SS
370
513 O-ring Viton
Cast iron ASTM A48 CL20 Mechanical seal See seal chart
383
108 Adapter
108 Adapter Cast iron ASTM
Hex head cap screw (adapter to motor) 228 Bearing frame A48CL20
Steel SAE 1200 series
371
134 Bearing cover
Pump shaft Carbon steel
412A O-ring, Impeller 122
412F O-ring, shaft sleeve Viton
168 Ball bearing (inboard)
513 O-ring
112 Ball bearing (outboard)
Drain plug – 3⁄8 NPT 316L SS
408 382 Retaining ring

Mechanical seal See seal chart Hex head cap screw (adapter to bearing frame)
383 370B Steel

Mechanical Seal Hex head cap screw (bearing frame to cover)


370C
John Crane Type 21 Mechanical Seal
333A Lip seal BUNA-N
Part No.
Metal Intended 193 *Grease fitting Steel
Item Rotary Stationary Elastomers Parts Duty
180-210 250-360 123 V-ring deflector BUNA-N
Frames Frames
* M-Group only
Hot Water
10K19 10K20 EPR
383 Carbon Silicon 316 SS
Options Carbide Mild Abrasive
10K27 10K45
Viton
Severe Duty
10K64 10K65 Sil-Carb.

GOULDS PUMPS
Commercial Water 26
SSH – Engineering Data S-Group

Channel Steel Bedplate, Clockwise Rotation Viewed from Drive End

DISCHARGE CP 3¾ CREF
AB Y Z
MAX. SPACER COUPLING
PRIME PLUG 3½ COUPLING GUARD
1.125
X Ø
1.124
SUCTION
P
SINGLE PHASE ONLY MAX. (4)
HOLES
DC DD 5
MAX. KEYWAY 1⁄8 x ¼ ⁄8 DIA.
HD

HG
DRAIN PLUG
HE HE 3
⁄8" – 19 BSP HL HF HP
HA HB

Dimensions and Weights – Determined by Pump Dimension “HL” Determined NOTES:


by Pump and Bedplate 1. All pumps shipped in vertical
discharge position. May be rotated
in 90° increments. Tighten 3⁄8 – 16
Motor Frame Size casing bolts to 12 ft./lbs. torque.
2. Dimensions in inches.
Suction* Discharge* CP DC Max. DD X Y Z Wt. (lbs.) 143/ 183/ 213/ 254/ 284/ 3. Motor dimensions may vary with
Pump
145 184 215 256 286 motor manufacturer.
9SH 1 X 2–6 5 4¾ 63⁄8 1 56 4. Not to be used for construction
163⁄4 3 ⁄8 7 91⁄8 75⁄8 37⁄8
10SH 1 X 2–8 2 1 55⁄8 53⁄8 71⁄8 3 ⁄8 64 purposes.
11SH 1 X 2–10 179⁄16 67⁄8 65⁄8 7
8 ⁄8 4 86 10 8½ 4¾
4SH 1½ X 2½–6 169⁄16 5 4¾ 63⁄8 3¼ 57 9¼ 7¾ 4

7SH 1½ X 2½–8 55⁄8 53⁄8 66
2½ 71⁄8
5SH 2 X 2½–6 5 4¾ 35⁄8 57
2 175⁄16 4 10 8½ 4¾
8SH 2 X 2½–8 68
6 5¾ 715⁄16
6SH 2½ X 3–6 3 2½ 59
* For use with ANSI Class 150 mating flanges.

Available Motor and Bedplate Dimensions and Weights

Motor HP @ 3500 RPM HP @ 1750 RPM Bedplate Data


Frame AB P Wt.
Max. C REF Max. Max. Wt.
Single Phase Three Phase Single Phase Three Phase (lbs.) Motor Bearing
HA HB HD** HE HF HG HP* Shim Frame
Shim
ODP TEFC ODP TEFC ODP TEFC ODP TEFC
143T 1 1 1 1 133⁄8 45
5¼ 65⁄8 1¾
145T 2 2 2–3 2 1½ 1½ 1½ – 2 1½ – 2 14¼ 53
10 28 8 3¾ 24 2¾ ¾ 48 —
182T 3 3 5 3 2 2 3 3 165⁄8 74
57⁄8 77⁄8 ¾
184T 5 5 7½ 5 3 or 5 3 5 3 181⁄8 95
213T 10 7½ 18 116
73⁄8 95⁄8 12 31 8¼ 4¼ 29 3 1 65 — —
215T 15 10 191⁄8 136
254T 20 15 215⁄8 266
101⁄8 13 13 42 10¼ 5¼ 38½ 4 110 — 1
256T 25 20 233⁄8 264

284TS 30 25 247⁄8 392
125⁄8 15 15 44 10½ 5¾ 40½ 3½ 124 – 1¾
286TS 40 30 265⁄8 432
Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs.
* “HP” Dimensions at motor end only.
** “HD” Dimension for 254T/256T motor frame on 1 x 2-10 only is 11"; A ¾" motor shim and a 1¾" bearing frame shim are required.

GOULDS PUMPS
Commercial Water 27
SSH-F – Engineering Data M-Group

Channel Steel Bedplate, Clockwise Rotation Viewed from Drive End

CP C REF.

ABMAX. DISCHARGE Y 41 5 ⁄ 1 6 3 3⁄4


SPACER COUPLING

PRIME PLUG 3 7⁄ 8 COUPLING GUARD

1.625 SINGLE PHASE


ONLY
1.624

SUCTION

PMAX.

DC DD 4 HOLES
MAX. KEYWAY
3/16 X 3/8
5⁄8
HD

DRAIN HG
PLUG

HE HE L HF 13 ⁄ 4
3/8” 3GAS
⁄8" –THREAD
19 BSP
UNI ISO 228/1
HA HB

Dimensions and Weights – Determined by Pump, NOTE:


1. Pumps will be shipped with top verti-
cal discharge as standard. For other
DC Wt. orientations, remove casing bolts,
Pump Size,
Suction* Discharge* Max. (lbs.) rotate discharge to desired position
Pump CP DD L X Y
and tighten 3⁄8 – 16 bolts to 12 ft./lbs.
2. ALL dimensions in inches.
24SH 1½ x 2½-10 1½ 125 3. Not for construction purposes.
2½ 67⁄8 65⁄8
25SH 2 x 2½-10 2 1
815⁄16 125
23 10 ⁄8 4
22SH 2½ x 3-8 61⁄8 57⁄8 125
3 2½
27SH 2½ x 3-10 134
67⁄8 65⁄8 915⁄16
23SH 3 x 4-8 1
136
4 3 24 11 ⁄8 5
28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 148
* For use with ANSI class 150 mating flanges.

Available Motor and Bedplate Dimensions and Weights

Motor HP @ 3500 RPM HP @ 1750 RPM – T-Frame Only Bedplate Data


Frame AB P Wt.
Three Phase Single Phase Three Phase Max. C Max. Max. Wt.
HA HB HD HE HF HG (lbs.)

ODP TEFC ODP TEFC ODP TEFC


184T 3 or 5 3 5 5 57⁄8 181⁄8 77⁄8 95
213T 7½ 7½ 18 116
73⁄8 95⁄8
215T 15 10 10 191⁄8 136 13 42 101⁄4 51⁄4 38½ 4 111
254T 20 15 15 15 215⁄8 266
91⁄2 13
256T 25 20 20 20 233⁄8 264
284TS/T 30 25 25 25 247⁄8 392
125⁄8 15 15 44 10½ 5¾ 40½ 3½ 124
286TS/T 40 30 265⁄8 422
324TS/T 50 40 283⁄4 592
141⁄8 173⁄8 12
326TS/T 60 50 30¼ 634
18 48 7¼ 44½ 4 183
364TS/T 75 60 315⁄8 834
151⁄8 187⁄8 13
365TS/T 100 75 325⁄8 1000
405TS/T 100 18 367⁄8 205⁄8 1060 22 56 14 7¼ 52½ 4 214
Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs.

GOULDS PUMPS
Commercial Water 28
SSH Close Coupled – Dimensions and Weights S-Group

(All dimensions in inches and weights in lbs. Do not use for construction purposes.)

DISCHARGE Y Z CREF
AB MAX.

PRIME PLUG

X
SUCTION

P
MAX.

D DC DD
G MAX.

H-(4) HOLES
E E DRAIN PLUG L F F
A 3
⁄8" – 19 BSP B

150 lb. Flange DC NOTE:


DIM. “L” (Motor Frame Size) Wt.
Pump (lbs.)
1. Pumps shipped in vertical discharge as
Max.
DD X Y Z standard. For other orientations, remove
Suct.* Disch.* casing bolts, rotate discharge to desired
143/145 182/184 213/215 254/256
position, and tighten 3⁄8 – 16 bolts to
9SH 1x2–6 5 4¾ 63⁄8 1
24 12 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs.
3 ⁄8 93⁄8 10½ 11½ —
10SH 1 x 2 – 8 2 1 55⁄8 53⁄8 71⁄8 37⁄8 32 2. ALL dimensions in inches.
11SH 1 x 2 – 10 67⁄8 65⁄8 87⁄8 4 10¾ 113⁄8 123⁄8 125⁄8 54 3. Motor dimensions may vary with motor
4SH 1½ x 2½ – 6 5 4¾ 63⁄8 3¼ 9¾ 103⁄8 113⁄8 — 25 manufacturer.

7SH 1½ x 2½ – 8 55⁄8 53⁄8 71⁄8 34 4. Not for construction purposes.

5SH 2 x 2½ – 6 5 4¾ 71⁄8 4 35⁄8 25
2 10½ 111⁄8 121⁄8 123⁄8
8SH 2 x 2½ – 8 5¾ 15
36
6 7 ⁄16
6SH 2½ x 3 – 6 3 2½ 4¾ 27
* For use with ANSI class 150 mating flanges.

Dimensions Determined by JM Motor Frame Motor Frame Selections

H P Motor Wt. Motor Horsepower


JM Frame Motor
A AB B D E F G CREF Dia. Max. (lbs.)
Frame 3500 RPM 1750 RPM
1Ø 3Ø 1Ø 3Ø
143JM 2 1 11
41 ODP TEFC ODP TEFC ODP TEFC ODP TEFC
6½ 5¼ 6 3½ 2¾ ⁄8 11¼ ⁄32 65⁄8
145JM 2½ 57 143JM – – – – – – 1 1
182JM 7
2¼ 3 7
77 145JM 2 2 2-3 2 1-1½ 1-1½ 1½-2 1½-2
8½ 6 ⁄8 6½ 4½ 3¾ ⁄16 13½ 7 ⁄8
184JM 13
97 182JM 3 3 5 3 2 2-3 3 3
2¾ ⁄32
213JM 122 184JM 5 5 7½ 5 3 – 5 5
9½ 73⁄8 8 5¼ 4¼ 7
⁄32 15½ 95⁄8 213JM 7½ – 10 7½ 5 – 7½ 7½
215JM 3½ 155
254TCZ 9½ 41⁄8 265 215JM 10 – 15 10-15 – – – –
11¼ 9 6¼ 5 ¼ 185⁄8 17
⁄32 11½ 254TCZ – – 20 – – – – –
256TCZ 11¾ 5 320
256TCZ – – 25 20 – – – –

GOULDS PUMPS
Commercial Water 29
SSH Close Coupled – Dimensions and Weights M-Group

(All dimensions in inches and weights in lbs. Do not use for construction purposes.)
CPMAX.

DISCHARGE Y
AB MAX. 415⁄16

PRIME PLUG

SUCTION

P MAX.

D DC
G MAX.DD

DRAIN PLUG H-4 HOLES


E E L F F
3
A ⁄8-19 BSF B

Dimensions “L” Determined by Pump and Motor

CP DC Wt. Motor Frame Size


Pump Size Max.
Suction* Discharge* Max. (lbs.)
Pump DD X Y

140 180 210 250 280 320 360

24SH 1½ x 2 ½-10 1½ 34½ 75 10½ —


2½ 67⁄8 65⁄8
25SH 2 x 2½-10 2 815⁄16 75 111⁄8
4 121⁄8 137⁄8 143⁄8
22SH 2½ x 3-8 36 61⁄8 57⁄8 72 — 15
3 2½
27SH 2½ x 3-10 84 — —
67⁄8 65⁄8 915⁄16
23SH 3 x 4-8 86 11½ 121⁄8
4 3 37 5 133⁄8 147⁄8 153⁄8 16
28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 98 — —
* For use with ANSI class 150 mating flanges. NOTES:
1. Pumps shipped in vertical discharge as standard.
For other orientations, remove casing bolts, rotate
discharge to desired position, and tighten 3⁄8 –
16 bolts to 12 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs.,
½ – 13 bolts to 35 ft./lbs.
2. Motor dimensions may vary with motor manufacturer.
3. Not for construction purposes.

Dimensions Determined by JM Motor Frame Motor Frame Selections

Frame AB P Max. Motor Horsepower


A B D E F G H Wt.
Max. Frame 3500 RPM 1750 RPM Max.
1 11
145JM 6½ 5¼ 6 3½ 2¾ 2½ ⁄8 ⁄32 73⁄16 3 PH 1 PH 3 PH
182JM 7
2¼ 3 ODP TEFC ODP TEFC ODP TEFC
8½ 5 ⁄8 6½ 4½ 3¾ ⁄16 8½
184JM 13 145JM – – – – 2 2 57
2¾ ⁄32
213JM
9½ 73⁄8 8 5¼ 4¼ 7
⁄32 103⁄16 182JM – – 2 2, 3 3 3 77
215JM 3½
184JM – – 3 – 5 5 97
254JM 41⁄8
11¼ 9 11¾ 6¼ 5 13¼ 213JM 10 – 5 – 7½ 7½ 141
256JM 5 17
¼ ⁄32 215JM 15 10 – – 10 10 155
284JM 4¾
12¼ 12¼ 12¼ 7 5½ 15 254JM 20 15 – – 15 15 265
286JM 5½
324JM 5¼ 256JM 25 20 – – 20 20 320
5
14 13¼ 14 8 6¼ ⁄16 1615⁄16 284JM 30 25 – – 25 25 419
326JM 6 21
⁄32 286JM 40 30 – – – – 422
364TCZ 55⁄8
17¾ 151⁄8 15½ 9 7 1 19 324JM 50 40 – – – – 562
365TCZ 61⁄8
326JM 60 50 – – – – 625
364TCZ and 365TCZ frames are built with 326JM shaft extensions.
Dimensions may vary with manufacturer. 364TCZ 75 60 – – – – 775
365TCZ 100 75, 100 – – – – 905
364TCZ and 365TCZ frames are built with 326JM shaft extensions.

GOULDS PUMPS
Commercial Water 30
SSH Frame Mounted – Dimensions and Weights S-Group

CP
DISCHARGE
Y Z

PRIME PLUG

X 3½
SUCTION
1.125
DIA.
1.124

DC KEYWAY 1⁄8 x ¼, CHAVETERO 1⁄8 x ¼



MAX.DD 7
⁄16 DIA. – (4) HOLES

½
2¾ 2¾ DRAIN PLUG L 5 ¾
7 3 6½
⁄8" – 19 BSP

Dimensions and Weights – Bare Pump Only

150 lb. Flange Wt. NOTE:


DC CP
Pump Max. (lbs.) 1. Pumps will be shipped
DD Max. L X Y Z
Suction* Discharge* with top vertical discharge
as standard. For other
9SH 1x2–6 5 4¾ 63⁄8 1 56 orientations, remove casing
163⁄4 77⁄8 3 ⁄8 bolts, rotate discharge to
10SH 1 x 2 – 8 2 1 55⁄8 53⁄8 71⁄8 37⁄8 64
11SH 1 x 2 – 10 67⁄8 65⁄8 179⁄16 8¾ 87⁄8 4 86
desired position, and tighten
3
⁄8 –16 bolts to 12 ft./lbs.,
4SH 1½ x 2½ – 6 5 4¾ 169⁄16 7¾ 63⁄8 3¼ 57 7
1½ ⁄16 – 14 bolts to 20 ft./lbs.
7SH 1½ x 2½ – 8 55⁄8 53⁄8 65 2. ALL dimensions in inches.
2½ 71⁄8
5SH 2 x 2½ – 6 5 4¾ 35⁄8 57 3. Not for construction
2 175⁄16 8½ 4
8SH 2 x 2½ – 8 68 purposes.
6 5¾ 715⁄16
6SH 2½ x 3 – 6 3 2½ 59

* For use with ANSI class 150 mating flanges.

GOULDS PUMPS
Commercial Water 31
SSH Frame Mounted – Dimensions and Weights M-Group

CP

DISCHARGE Y 415⁄16

PRIME PLUG

37⁄8

SUCTION 1.625
DIA.
1.624

KEYWAY
3⁄16X3⁄8
61⁄4 DC DD
MAX. 4 HOLES
9⁄16 DIA .

1⁄2
31⁄2 31⁄2 DRAIN PLUG L 61⁄2 1”

81⁄2 3/8” – BSP 81⁄2

Dimensions and Weights – Bare Pump Only

DC Wt.
Pump Size (lbs.)
Suction* Discharge* Max. DD L X Y
Pump CP

24SH 1½ x 2½-10 1½ 125


2½ 67⁄8 65⁄8
25SH 2 x 2½-10 2 815⁄16 125
23 10¼ 4
22SH 2½ x 3-8 61⁄8 57⁄8 125
3 2½
27SH 2½ x 3-10 134
67⁄8 65⁄8 915⁄16
23SH 3 x 4-8 136
4 3 24 11¼ 5
28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 148
* For use with ANSI class 150 mating flanges.

NOTES:
1. Pumps will be shipped with top vertical discharge as
standard. For other orientations, remove casing bolts,
rotate discharge to desired position, replace and tighten
3
⁄8 –16 bolts to 12 ft./lbs.
2. Motor dimensions may vary with motor manufacturer.
3. Not for construction purposes.

GOULDS PUMPS
Commercial Water 32
Specifications

Capacities to: NOTE: Overload protection must


1100 GPM (250 m3/hr) at be provided. Contactor with
3500 RPM 775 GPM (177 m3/hr) overload for single phase or starter
at 1750 RPM with heaters for three phase
ordered separately.
Heads to:
525 feet THD (158 m) at Motor (frame mounted):
3500 RPM NEMA standard T-frame open
130 feet THD (40 m) at drip-proof, totally enclosed and
1750 RPM explosion-proof (three phase only)
enclosures 60 Hz, 1750 or
Maximum working pres-
3500 RPM.
sures to: 230 PSI (15 bars)
Single phase (115/230 V)
Maximum temperatures to: 1750 RPM, 1 – 5 HP
250°F (121°C) Three phase (208 – 230/460 V)
3500 RPM, 3 – 125 HP
All wetted components of
1750 RPM, 1 – 25 HP
AISI: Type 316L stainless steel
material. NOTE: Overload protection must
be provided. Contactor with
Rotation: Clockwise when
overload for single phase or starter
viewed from motor end.
with heaters for three phase
Enclosed impeller and ordered separately.
replaceable wear ring:
Optional: Rigid carbon steel bed-
for high efficiency and maximum
plate, sheet metal coupling guard
wear life.
designed to OSHA specifications
Motor (close coupled): and T.B. WOODS type “SC” spacer
NEMA standard JM shaft open couplings.
drip-proof, totally enclosed and
explosion-proof enclosures, 60 Hz,
1750 or 3500 RPM.
Single phase ODP (115/230 V)
1750 RPM, 1 – 5 HP.
Three phase ODP. TEFC/Exp. proof
(208 – 230/460 V).
3500 RPM, 2 – 100 HP
1750 RPM, 1 – 25 HP

GOULDS PUMPS
Commercial Water 33
Typical Applications

HVAC Specifically designed for all


traditional cast iron or bronze
fitted water and low grade
corrosive services.
• Water circulation
• Booster systems
• Liquid transfer
• HVAC pump replacements
• General service pumping

Water truck PCB washer

Tubing washer Textile dyes

Reverse osmosis Boiler feed

GOULDS PUMPS
Commercial Water 34
Notes

GOULDS PUMPS
Commercial Water 35
IT T Commercial Water

ITT Corporation.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

© 2006 ITT Corporation

Engineered for life

Potrebbero piacerti anche