CPRI/Ir interface:
Overcurrent case:
The Radio Module has detected over-current on the ALD port. Some antenna line device is causing overload. Depending on hardware implementation, antenna line devices powered by the RS485 IUANT, or powered by the antenna line, are out of order.
Undercurrent case:
The Radio Module has detected undercurrent on the ALD port. There is a problem with ALD port connection. Depending on hardware implementation, antenna line devices powered by the RS485 IUANT, or powered by the antenna line, are out of order.
State Start
Unit status Degraded
Unit status
attributes
Effect The ALD interface is not operating correctly. Communication with TILT devices is not possible.
Reported 7652 BASE STATION NOTIFICATION
alarms
7654 CELL OPERATION DEGRADED
2. For CPRI-A radios, the fault may cancel automatically if the CPRI-A radio reports that Overcurrent on AISG port no longer exists. If fault is not cancelled automatically, the fault is cancelled when the CPRI-A radio is reset, after BTS Site reset, or BTS is blocked and/or unblocked.
3. For all other radios, the alarm is cancelled only when the RF Module is reset, or if the BTS is reset.
Related
faults
Related topics
Fault view