Sei sulla pagina 1di 1

Notes:-

L[O0]03

10,150
200 200 200
4,900 4,650
1,150 3,000 2,475 2,000 1,525
200

200
TERRACE
2,000

2,000
1,800

1,800
ceramic tiles f.f

W1/PVO
200

200
D1
1,450

MASTER BEDROOM

3,800
ceramic tiles f.f
W1/PVO

4,701
4,500

2,000

LOUNGE
ceramic tiles f.f

200
2,100

D2 D2
200

arch

W4/PVO

1,800
BATHROOM

1,000
ceramic tiles f.f MH Roof pitch 25deg
W5/PVO
15,400

15,400
Roman clay tiles on
L[O0]04

L[O0]02
timber structure to SE

200
985
W2/PVO
3,100

1,800

DINNING
ceramic tiles f.f
details
CIRCULATION
ceramic tiles f.f

W2/PVO
BEDROOM 1

1,800
D2 ceramic tiles f.f

3,300
850

S-01 S-01
200

400

400
D2
F

D2 +3.000m
CEILING
2,065
200
3,200

KITCHEN
3,400

ceramic tiles f.f LEVEL


200mm thick
RE

D2
reinforced ring
D2 beam to S.E.
W2/PVO

200

1,500 200
3,500
1,800

detail
200

D3 BEDROOM 2
W3/PVO ceramic tiles f.f
1,600

BATHROOM
1,800

3,000

3,000
TERRACE ceramic tiles f.f
1,050

ceramic tiles f.f

BED ROOM1 DINNING


200

200

200mm thick brick


W4/PVO

2,400
MH MH wall pastered and
200 200 200 200 200 finished with
650 3,600 1,700 3,200
350 150 550 textured, Weather
850 600 1,800 900 1,000 3,949 guard paint to

900
10,150
to septic tank architects approval

GROUND FLOOR SPLASH SPLASH ±0.000


LEVEL APRON APRON

L[O0]01

L[00]01 GROUND FLOOR PLAN anti-termite treatment required anti-termite treatment required
around all foundation excavations, around all foundation excavations,
SCALE 1:100
200x600mm c0nc' strip fdt'n 200x600mm c0nc' strip fdt'n
class 15 conc' (1:3:6mix) on class 15 conc' (1:3:6mix) on
50mm sand blinding bed on 50mm sand blinding bed on
6,100
well compacted earth. FOUNDATION CONSTRUCTION NOTES
well compacted earth.
200x600xL concrete strip foundations Floor finishes: 300x300x10 approved non-slip
(mix 1:3:6) to receive 200mm thick plinth walls. ceramic tiles jointing in cement mortar, grouting joints with
2,000

Foundation depth to be determined on site and white cement or 25mm thick sand-cement (1:4) screed.
to be not less than 750mm. Column bases and 150mm thick slab: class 15 concrete (1:3:6); DATE REVISIONS R E MARKS
4,850
all structural reinforcements to S.E. drawings on 1000gauge polythene sheeting DPM on 15mm
an specifications sand blinding on 200mm hardcore rammed/compacted
earth base (more details to S.E. specification).

L[00]01 SECTIONAL PLAN


11,000

SCALE 1:100
14,200

850
5,200

CLIENT

OWNER'S SIGNATURE

10,100 -----------------------------------

L[00]01 ROOF PLAN SHEET TITLE

SCALE 1:100
ARCHITECTS Drawing No.

SCALES DATE CHECKED BY DESIGNED AND DRAWN BY


August 2017 KASOZI DENIS
as shown in the drawings

GSPublisherVersion 0.0.100.100

Potrebbero piacerti anche