Sei sulla pagina 1di 5

Technical note

Syringe guide for instrumental insemination


apparatus of queen bees (Apis mellifera L)

J Woyke

Agricultural University, SGGW,Bee Culture Division, Nowoursynowska 166,


Warsaw 02-766, Poland

(Received 9 June 1990; accepted 5 November 1990)

Summary — The syringe guide consists of a long thick wire rod fixed to the syringe holder. This rod
allows an inseminator to make all syringe-tip movements by moving the guide with his left hand. The
right hand is then free to insert the syringe-tip and semen into the vagina, without the inconvenience
of removing the hand from the syringe. The guide enables queens to be inseminated more quickly
and with less discomfort. Construction of the guide is simple and economical.

Apis mellifera / instrumental insemination / apparatus

INTRODUCTION easier, professional inseminators have


discontinued using the valve-fold probe.
Instrumental insemination is now used on Introduction of the syringe-tip into the
a large scale for mass insemination of queen’s genital tract requires very precise
movements. In Mackensen’s apparatus,
queen bees. One inseminator inseminates the
scores of queens per day. It is therefore tip was lowered by pushing the sy-
important to improve the apparatus in ringe down. Inclination of the syringe (dor-
so-ventral movements in relation to the
such a way as to make insemination easy,
quick and with a minimum of discomfort. queen) was also performed directly by
hand. The transversal movements (right
Of course, the collection of semen from
and left in relation to the queen) were
the drones is the most time-consuming
made by revolving the entire syringe
procedure. block, with the syringe in the holder,
The procedure of introduction of the sy- around the vertical support. This type of
ringe tip into the queen’s vaginal orifice apparatus is still used by nearly everyone
can be improved upon. Originally, Mack- performing instrumental insemination of
ensen and Roberts (1948) as well as Laid- bees in the USA (Harbo, 1989). Due to
law (1944, 1977) used the vaginal probe the lever principle, small movements
to lower the vaginal valve-fold. The tip made by hand at the level of the syringe
was then introduced behind that probe. block holder result in large movements at
However to make insemination faster and the tip of the needle. These hand-directed
movements made it difficult for the inexpe- discs without looking. The syringe holder
rienced to introduce the tip into the genital or the micromanipulator became compli-
orifice. Vesely (1966) therefore added a cated, difficult to construct and expensive
screw adjustement to the syringe holder. to buy.
By turning a screw, the syringe inclination
was altered, and the tip of the needle was
moved dorso-ventrally. But the transversal RESULTS
movements of the tip still had to be carried
out by hand, rotating the block holder with
the syringe around the vertical support. Construction of the syringe guide
This procedure was improved upon by
Schley (1983), who constructed another A simple and useful syringe guide has
adjustment, which enables transversal been constructed in Poland (fig 1).Ital-
movements of the syringe with the tip.
lows all tip movements to be directed with
Swienty in Denmark has constructed a one hand, while the other hand is used to
precise apparatus provided with 3 micro- introduce the syringe tip into the queen’s
manipulators (Holm, 1986). Each manipu- genital orifice. The guide consists of a long
lator moves one of the 2 hooks or the sy-
thick wire rod fixed to the syringe holder
ringe. The movements are very precise; (fig 2). Due to the lever principle, large
however, the hook’s possibilities are so movements at the end of the guide result
limited that the queen’s abdomen cannot
in small precise movements at the tip of
be opened by them. Pointed forceps have
the syringe needle.
to be used to open the abdomen. Dorso-
ventral or vertical syringe movements can Before the be fixed to the ap-
guide can
be made with the help of the micromanipu- paratus, the syringe holder must be fixed
lator. But transversal movements of the permanently to the head of the bolt on
hooks or the syringe have to be made by which the holder rotates vertically in the sy-
turning additional screws. Different modifi- ringe block (fig 3a). The bolt should be
cations of the apparatus for instrumental also longer than in the Mackensen appara-
insemination have been described in the tus. It should protrude 2 cm above the nut
latest manual on instrumental insemination which holds the spiral spring between it
(Moritz, 1989). and the block.
All the above improvements have cer- Next a wire 26 cm long and 6 mm
=

tainly presented some progress in the de- thick is selected. The wire can be > 6 mm
velopment of the apparatus for instrumen- thick, but should not be too thin, because it
tal insemination. Nevertheless, all these might then be too flexible for precise move-
adjustements did not resolve the problems ments. A transversal hole should be drilled
connected with the movements and intro- near one end of the rod (fig 3t). The bolt of
duction of the syringe tip into the genital the queen holder slips through the hole in
orifice of the queen. All tip movements as the guide, and the guide is fastened to the
well as the introduction of the tip into the bolt with 2 check nuts (fig 3 n). The 2 nuts
genital orifice had to be directed by the hold the end of the rod between them. It is
same hand. This required removing the possible to work with the guide fixed in this
right hand from the syringe or the micro- manner, but it is better to use a set screw
manipulator to turn the screw discs for ad- which keeps the guide from slipping on the
ditional adjustments, and either looking bolt. The set screw penetrates the proxi-
away from the microscope or turning the mal end of the guide (fig 3s). A hole is
movements at the tip of the needle are
made with the aid of the guide by moving it
with the left hand. The entire procedure of
the introduction of the tip into the queen’s
vagina is made by the right hand without
removing it from the syringe.
First, the tip of the needle is positioned
near the dorsal edge of the vaginal orifice.
Next it is inserted 0.5 mm into the vagi-
=

na. Then the distal end of the guide is lifted


with the left hand. As a result, the tip of the
needle is moved ventrally. During that
movement the valve-fold is pressed
against the ventral side of the vagina, re-
drilled from the end of the rod along its
sulting in opening of the entrance to the
axis to the hole for the bolt. median oviduct. The tip is then inserted =

1.5 mm deeper, and the semen injected


through the median oviduct into both later-
Procedure of queen insemination with al oviducts.
the help of the guide
It is even possible to make the 2 steps
of tip introduction in one continuous inser-
Insemination of the queen is facilitated tion. While the right hand monitors the in-
both by the use of the guide, and rejection troduction of the syringe tip into the vagina,
of the valve-probe. First, the tip is filled the left hand ensures that at the same time
with semen, and the queen is prepared for the tip is moved dorso-ventrally with the
instrumental insemination as usual. All the aid of the guide. After the semen has been
injected into the queen’s reproductive or- 1 g). Ce guide consiste en une longue tige
gans, the tip is withdrawn and insemina- métallique fixée au support de la seringue
tion is completed. (fig 2 h; b bloc seringue). Par le principe
=

du levier, de larges mouvements imprimés


à l’extrêmité le guide produisent des petits
ACKNOWLEDGMENTS mouvements précis à la pointe de la serin-
gue. Le support de la seringue doit rester
constamment relié à la tête de la vis à la-
The present version of the guide was elaborat-
ed at the Bee Division of the Agricultural Univer- quelle le guide est fixé (fig 3a).
sity in Warsaw. We acknowledge the invaluable Pendant l’insémination artificielle de la
help of Mr &jadnr;Iϵ k and Dr Ja&jadnr;i&jadnr;ski in devising and reine, tous les mouvements de l’extrémité
improving the guide. de la pointe sont exécutés avec le guide
en le déplaçant avec la main gauche. Tout
le travail d’introduction de la pointe dans le
Résumé — Guide pour la seringue de
vagin de la reine est réalisé par la main
l’appareil pour l’insémination artificielle droite sans avoir à lâcher la seringue. Ceci
des reines d’abeilles. L’introduction de la
permet d’inséminer des reines plus rapide-
pointe dans le tractus génital de la reine ment et plus facilement. La construction de
nécessite des mouvements très fins de la ce guide est plus facile et moins coûteuse
seringue. Dans l’appareil de Mackensen, que celle des autres dispositifs.
l’inclinaison de la seringue était obtenue
manuellement par des déplacements di- Apis mellifera / insémination artificielle /
rects de celle-ci et les mouvements trans- appareil
versaux en faisant pivoter tout le bloc de la

seringue autour du support vertical. Par le


principle du levier, de petits mouvements Zusammenfassung — Leitstab für die
imprimés manuellement au niveau du bloc Spritze des Apparates zur Besamung
von Bienenköniginnen. Die Einführung
seringue produisaient des mouvements der Spitze in den Eileiter der Königin erfor-
amples à la pointe de la seringue remplie dert sehr feine Bewegungen der Spritze.
de sperme.
Bei dem ursprünglichen Mackensen-
C’est
pourquoi Vesely (1966) a construit Apparat wurde die Neigung der Spritze
un support de seringue avec réglage par durch direkte Bewegung mit der Hand
vis, qui permet de modifier l’inclinaison de verändert. Die Bewegungen in transversa-
la seringue. Schley (1983) a construit un ler Richtung wurden durch Drehung des
autre support qui permet les mouvements
ganzen Spritzenblocks mit der Spritze um
transversaux de la pointe. Mais la mani- den senkrechten Spritzenhalter bewirkt. In-
pulation des vis des supports comme l’in- folge des Hebelprinzips führten geringe
troduction même de la pointe doivent être Bewegungen, ausgeführt von Hand am
faites avec la même main. Il faut pour cela Spritzenblock, zu großen Bewegungen der
que la main droite lâche la seringue pen- mit Samen gefüllten Spritze. Das hatte
dant l’insémination. Le support devenait Schwierigkeiten bei der Einführung der
très complexe et coûteux. Spritze in die Genitalöffnung der Königin
Un guide pour la seringue, simple et zur Folge.

pratique, a été construit à l’Institut apicole Deshalb konstruierte Vesely (1966) ei-
de l’université d’agriculture de Varsovie (fig nen Spritzenhalter mit Stellschraube,
durch welche die Neigung der Spritze Leitstabes ist einfacher und billiger als
verändert werden konnte. Schley (1983) andere Vorrichtungen.
konstruierte eine andere Vorrichtung,
welche Bewegungen der Spritze in trans- Apis mellifera / instrumentelle Besam-
versaler Richtung ermöglichten. Aber so- ung / Apparat
wohl die Betätigung der Schrauben dieser
Vorrichtung wie die Einführung der Spritze
selbst in die Scheide hatten mit derselben REFERENCES
Hand zu erfolgen. Deshalb mußte man
während des Besamungsvorganges den Harbo JR (1989) Equipment used in the USA.
In: The Instrumental Insemination of the
Griff der rechten Hand zur Bedienung der
Queen Bee (Moritz RFA, ed) Apimondia, Bu-
Schrauben am Spritzenblock wechseln. charest, 47-51
Der Spritzenhalter wurde sehr kompliziert Holm E (1986) Artificial Insemination of the
und teuer. Queen Bee. A Manual for the Use of Swien-
Am Bieneninstitut der Landwirtschaftli- ty’s Insemination Apparatus. Publ Eigil Holm,
chen Universität Warschau wurde eine ein- Byskovsvej 4, DK-8751 Denmark
Laidlaw HH Jr (1944) Artificial insemination of
fache und nützliche Leitvorrichtung für die
the queen bees (Apis mellifica L). Morpholo-
Spritze konstruiert (Abb 1 g). Die Vorrich- gical basis and results. J Morphol 74, 429-
tung besteht aus einem langen, dicken 465
Metallstab, der an dem Spritzenhalter be- Laidlaw HH Jr (1977) Instrumental Insemination
festigt ist (Abb 2h; b Spritzenblock). Ent-
=
of Honey Bee Queens. Dadant and Sons,
sprechend den Hebelgesetzen führen aus- Hamilton, IL
giebige Bewegungen am Ende des Mackensen O, Roberts WC (1948) A Manual for
Leitstabes zu geringen, feinen Bewegun- the Artificial Insemination of Queen Bees.
gen der Spritzenspitze. Der Spritzenhalter USDA, Bur Entomol Plant Quarant, ET-250
muß dabei fest mit dem Kopf der klemm Moritz RFA (ed) (1989) The Instrumental Insemi-
sckraube verbunden bleiben (Abb 3a); zur nation of the Queen Bee. Apimondia, Bucha-
rest
welche der Laitstab befestig ist.
Schley P (1983) Praktische Anleitung zur instru-
Während der instrumentellen Besa- mentellen Besamung von Bienen-
mung der Königin werden alle Bewegun- königiennen. Selbstverlag, Giessen
gen des Spritzenendes mit Hilfe des Vesely V (1966) Description of and handling
Leitstabes durch Betätigung mit der linken with, the insemination equipment used at the
Hand gesteuert. Der gesamte Vorgang der course on artificial insemination of queen
bees. In: Manual on Artificial Insemination of
Einführung der Spritze in die Scheide der the Queen Bees (Woyke J, Ruttner F, Vesely
Königin erfolgt mit der rechten Hand, V, eds) Dol (Czech), Vyzkumny Ustav Vcelar-
welche dabei ständig an der Spritze ver-
sky, 35-67
bleiben kann. Dadurch kann die Besa-
Vesely V (1969) Modification of the Mackensen-
mung der Königinnen rascher und be- Roberts apparatus. In: The Instrumental In-
quemer durchgeführt werden als mit jedem semination of the Queen Bee (Ruttner F, ed)
anderen Apparat. Die Konstruktion des Apimondia, Bucharest, 35-37

Potrebbero piacerti anche