Prestressed Standard
Drawings, Details, and
Guidelines
Alabama DOT
Ohio DOT
Mississippi DOT
Louisiana DOTD
Arkansas DOT
ALDOT Quality Control Manual for Bridge Plan Detailing
ALDOT Quality Control Manual for Bridge Plan Detailing
ALDOT
Quality Control
Manual for
Bridge Plan
Detailing
ALDOT Quality Control Manual for Bridge Plan Detailing
ALDOT Quality Control Manual for Bridge Plan Detailing

Build-Up thickness at centerline of the bearings used


to set beam seat elevations is a function of camber
and roadway profile vertical curve ordinate
ALDOT Quality Control Manual for Bridge Plan Detailing
ALDOT Quality Control Manual for Bridge Plan Detailing
ALDOT Quality Control Manual for Bridge Plan Detailing
ALDOT Quality Control Manual for Bridge Plan Detailing
ALDOT Quality Control Manual for Bridge Plan Detailing
ALDOT Quality Control Manual for Bridge Plan Detailing
ALDOT Quality Control Manual for Bridge Plan Detailing
ALDOT Quality Control Manual for Bridge Plan Detailing
OHDOT
Library files for standard I-beam, adjacent box beam sections,
prestressing strands, live loads, and rebar
OHDOT
Adjacent Box Beams (non-composite and composite; 3’ & 4’ widths)
OHDOT Concrete I-beam Sections
OHDOT Concrete I-beam WF Sections
MDOT
General Bridge Notes
MDOT
Miscellaneous Span Details
MDOT
Beam Details
MDOT
Concrete Pile Notes
MDOT
Prestressed Pile Details
Seismic and Non-Seismic Standard Details for 14”, 16”, 18”, 20”, 24”, 30”, and 36” square
prestressed concrete piles
LADOTD
LG Girder Special Details and Specific Details
LADOTD
LG Girder Design
Aids
LADOTD
LG Girder
Dimensions
LADOTD
LG Girder Strand
Template
LADOTD
Girder Data Table
LADOTD
Camber Data Table
ARDOT
802 Precast-Prestress Concrete Products (partial)
• Method of Documentation of Acceptance
ARDOT
802 Precast-Prestress Concrete Products (partial)
• Method of Approval: Requirements of Precast/Prestress
Concrete Manufacturers
ARDOT
Bridge Division Policy Guidelines
• 4.1 Design Specifications
• AASHTO LRFD
• AASHTO Standard Specs
• 4.2 Design Loads
• 4.2.2.1 Non-Composite Loads Permanent Steel Deck Forms
for Prestressed AASHTO girders (12 or 15 psf)
• 4.2.2.2 Composite Loads
• FWS = 24 psf
• 4.3 Material Properties
• Minimum f’ci = 4500 psi
• 4.4.1 Beam/Girder Spacing
• 30-35% overhang width
• 4 beam/girder lines minimum
• Table 4.3: Beam/Girder Spacings for Standard Bridge
Widths
• 4.4.2.1 Design
• Deck Thickness 7.5” minimum with provision for 0.5”
sacrificial wearing surface
ARDOT
Bridge Division Policy Guidelines
• 4.4.4 Precast Prestressed Girders & Bulb-Tee
Sections Composite with Concrete Deck
❑ Design method – simple spans for non-
composite loads and continuous for LL and
composite DL. Link slabs my be acceptable.
❑ Draped/Straight Strands, Debonding
• Straight-debonded strands preferred.
Draped strands may be used.
❑ Haunch
• 2-inch minimum haunch to provide for
camber variations
• Maximum 3/8-inch projection into the
slab is typical to avoid interference with
the bar support when matching SIP deck
forms are used
ARDOT
Bridge Division Policy Guidelines
• 4.4.4.2 Detailing
• Include section showing positive
moment connections at continuity
diaphragms
• A4.10 New Jersey Railing Details
(TL-4)
ARDOT
Bridge Division Policy
Guidelines
• 4.7 Precast Concrete Spans
• Live Load Distribution Factor
• Spans shall be designed with
one wheel path on a unit for
moment and shear
• Railings for precast concrete
spans may be designed for a
Test Level Two (TL-2)
• See standard drawing nos. 55080
(19’), 55081 (25’), 55082 (31’), &
55083 for LRFD precast concrete
spans for 24’-6” and 28’-0” clear
roadways
ARDOT
Bridge Division Policy Guidelines
• 6.1 General
• Trestle Bents: Cap supported on tops of driven
piles
• 6.1.3 Materials
• Class S(AE) Concrete
• F’c = 5000 psi
• Application: precast prestressed concrete piling
• Prestressing strands (AASHTO M 203, Grade 250
or 270)
• Application: strands for precast prestressed concrete
piles
• 6.5.2.1 Driven Piles
• Concrete Piles
• 14” to 24” square
• Prestressed concrete piles preferred over non-
prestressed
• Shall not be used in seismic zones 3 and 4
• Pile anchorage shall be used in seismic zones 2 thru
4, see STD DWG No. 55021
ARDOT
Bridge Division Policy Guidelines
• 12.2.2 Prestressed Concrete
Girders
• AHTD Standard Specifications allow
the Contractor to propose an
“optional design”
• AHTD Subsection 802.22(b), casting
bed layouts should be reviewed as a
part of the shop drawings when
draped strand patterns are utilized
• A2.10 Procedure for Assessing the
Use of Accelerated Bridge
Construction
• ABC-Decision Flow Chart
• A8.6 Standard Bridge Drawings
ARDOT
Bridge Division Policy
Guidelines
A4.4 Prestressed
Girder and Bulb-Tee
Shapes
ARDOT
Bridge Division Policy Guidelines
A4.5 Example
Details-Prestressed
Girder and Bulb-Tee
ARDOT
Bridge Division Policy
Guidelines
• A12.1 Prestressed Girders Shop
Drawing Checklist
ARDOT
55022 Concrete Pile Standards LRFD
ARDOT
55008 Poured Silicone Joints
AHTD
Standard Specifications for Highway Construction
• Table 802-1 Class of Concrete
• Class S or S(AE) concrete for use in
prestressed concrete members
shall have a minimum compressive
strength of 5000 psi at 28 days
unless otherwise shown on the
plans.
• The maximum size of coarse
aggregate shall be 1”.