Sei sulla pagina 1di 6

IECEx Certificate

of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com

Certificate No.: IECEx BAS 04.0017X Issue No: 12 Certificate history:


Issue No. 12 (2013-08-02)
Status: Current Page 1 of 4 Issue No. 11 (2013-04-22)
Issue No. 10 (2011-11-25)
Date of Issue: 2013-08-02 Issue No. 9 (2011-10-12)
Issue No. 8 (2011-03-03)
Applicant: Rosemount Incorporated Issue No. 7 (2011-02-04)
8200 Market Boulevard Issue No. 6 (2010-05-06)
Chanhassen Issue No. 5 (2008-11-05)
Minnesota 55317 Issue No. 4 (2008-05-09)
United States of America Issue No. 3 (2008-04-04)
Issue No. 2 (2007-05-11)
Electrical Apparatus: Model 3051S Series Pressure Transmitter Issue No. 1 (2006-12-21)
Optional accessory:

Type of Protection: Intrinsic Safety

Marking: Ex ia IIC T4 Ga
-60°C ≤ Ta ≤ +70°C

Approved for issue on behalf of the IECEx R S Sinclair


Certification Body:

Position: General Manager

Signature:
(for printed version)

Date:

1. This certificate and schedule may only be reproduced in full.


2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.

Certificate issued by:


SGS Baseefa Limited
Rockhead Business Park
Staden Lane
Buxton
Derbyshire
SK17 9RZ
United Kingdom
IECEx Certificate
of Conformity
Certificate No: IECEx BAS 04.0017X Issue No: 12

Date of Issue: 2013-08-02 Page 2 of 4

Manufacturer: Rosemount Incorporated


8200 Market Boulevard
Chanhassen
Minnesota 55317
United States of America

Additional Manufacturing
location(s):
This equipment may be
manufactured at any of the
locations listed in QAR
GB/BAS/QAR06.0072/05.
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx
Scheme Rules, IECEx 02 and Operational Documents as amended.

STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was
found to comply with the following standards:

IEC 60079-0 : 2011 Explosive atmospheres - Part 0: General requirements


Edition:6.0
IEC 60079-11 : 2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Edition:6.0

This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the

Standards listed above.

TEST & ASSESSMENT REPORTS:


A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

IECEx ATR: File Reference:


UK/BAS/04/0283 04/0283
GB/BAS/ExTR11.0252/00 / GB/BAS/ExTR11.0288/00 11/0404 / 11/0848
GB/BAS/ExTR13.0058/00, GB/BAS/Ex13.0166/00 12/0376, 13/0508
IECEx Certificate
of Conformity
Certificate No: IECEx BAS 04.0017X Issue No: 12

Date of Issue: 2013-08-02 Page 3 of 4

Schedule

EQUIPMENT:
Equipment and systems covered by this certificate are as follows:

The Model 3051S Series Pressure Transmitters are designed to convert a process pressure measurement into 4-20 mA, HART,
Fieldbus, FISCO or Radio Frequency electrical signals. These signals are used to measure pressure, level or flow.

The Model 3051S Wireless Pressure Transmitter is supplied from a single Model 701PBKKF SmartPower Black Power Module, coded
Ex ia IIC T4/T5 Ga (-60°C ≤ Ta ≤ +40°C / +70°C) and covered by IECEx BAS 11.0026X or a Perpetuum Limited Intelligent Power
Module 71008, coded Ex ia IIC T4 Ga (-40°C ≤ Ta ≤ +85°C) and covered by IECEx BAS 13.0036X.

See Annex for additional details.

CONDITIONS OF CERTIFICATION: YES as shown below:

1. The Model 3051S Transmitters fitted with transient protection are not capable of withstanding the 500V test as defined in Clause
6.3.13 of EN 60079-11:2012. This must be taken into account during installation.

2. The terminal pins of the Model 3051S SuperModule must be provided with a degree of protection of at least IP20 in accordance with
IEC/EN 60529.

3. The Model 3051S enclosure may be made of aluminium alloy and given a protective polyurethane paint finish; however, care should
be taken to protect it from impact or abrasion if located in a zone 0 area.

4. The surface resistivity of the antenna is greater than 1G?. To avoid electrostatic charge build-up, it must not be rubbed or cleaned
with solvents or a dry cloth.

5. The Model 701PBKKF Power Module and Intelligent Power Module 71008 may be replaced in a hazardous area. The Power
Modules have a surface resistivity greater than 1GΩ and must be properly installed in the wireless device enclosure. Care must be
taken during transportation to and from the point of installation to prevent electrostatic charge build-up.

NOTE:
1. Conditions one and two do not apply to the Model 3051S Wireless Pressure Transmitter.
2. Conditions four and five only apply to the Model 3051S Wireless Pressure Transmitter.
IECEx Certificate
of Conformity
Certificate No: IECEx BAS 04.0017X Issue No: 12

Date of Issue: 2013-08-02 Page 4 of 4

DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):

Variation 12.1

To permit minor documentation changes that do not affect the original assessment.

Variation 12.2

To permit the Perpetuum Limited Intelligent Power Module 71008 to be used as an alternative power source for the Model 3051S
Wireless Pressure Transmitter.

ExTR: GB/BAS/ExTR13.0166/00 File Reference: 13/0508

Annex:

IECEx BAS 04.0017X Annex.pdf


SGS Baseefa Limited
Rockhead Business Park
Staden lane, Buxton, Derbyshire
SK17 9RZ
United Kingdom

ANNEX to IECEx BAS 04.0017X Issue No. 0 Date: 2013/04/22

The Model 3051S Series Pressure Transmitters are designed to convert a process pressure measurement into 4-20 mA,
HART, Fieldbus, FISCO or Radio Frequency electrical signals. These signals are used to measure pressure, level or
flow.

The equipment consists of a stainless steel 3051S Coplanar or Inline SuperModule attached to an epoxy-coated
aluminium alloy or stainless steel housing forming the configurations and model designations shown below.

Single or dual compartment housings provide field wiring terminals, optional transient protection, digital
communications, diagnostics and liquid crystal displays (LCD). The Quick Connect provides a plug and socket
connection to the SuperModule.

Configuration Model Designation


Pressure measurement using a SuperModule, or SuperModule with 3051S…A (4-20 mA/HART)
Quick Connect, or SuperModule with Single compartment (Junction
Box) housing and terminals and optional switches, transient protection
or Remote LCD.
Pressure measurement using a SuperModule with a dual compartment 3051S…A (4-20mA /HART)
(Plantweb) housing and terminals, optional switches, transient
protection, LCDs, diagnostics and communication options. 3051S…F (Fieldbus)
3051S…F...IA (FISCO)
Wireless pressure measurement using a SuperModule with a Plantweb 3051S…X (Wireless HART)
housing, power module, optional antennas and LCD meter.
Wired or Wireless DP Flow measurement using a SuperModule and 3051SF…A (4-20mA/HART)
Primary Flow Element with a Quick Connect or Junction Box/ Plantweb
3051SF…F (Fieldbus)
housing with terminals, optional switches, transient protection, local or
Remote LCD , diagnostics, communication, RTD, antennae and power 3051SF…F...IA (FISCO)
module (as applicable) .
3051SF…X (Wireless HART)
Differential pressure measurement using two SuperModules with 3051SAL… (4-20 mA/HART)
Junction Box or Plantweb housings and terminals, optional switches,
transient protection, local or Remote LCDs.
3051SAM…(4-20 mA/HART)

Wired or Wireless level measurement using a SuperModule with Quick 3051SAL_C…A (4-20 mA/HART)
Connect or Junction box/Plantweb housing with terminals, optional
switches, transient protection, local or Remote LCD , diagnostics, 3051SAL_C…F (Fieldbus)
communication, antennae and power module (as applicable)
3051SAL_C…X (Wireless HART)

4-20 mA/HART, Fieldbus and Profibus outputs are denoted by marking the appropriate check box on the label.

Input parameters:

Model Terminals Ui Ii Pi Ci Li
SuperModule +, - and CAN 30V 300mA 1.0W 30nF 0
3051S...A; 3051SF…A; 3051SAL…C +, - and CAN 30V 300mA 1.0W 12nF 0
3051S…F; 3051SF…F + and - 30V 300mA 1.3W 0 0
3051S…F…IA;
+ and - 17.5V 380mA 5.32W 0 0
3051SF …F…IA
3051S …A…M7, M8, or M9; 3051SF
…A…M7, M8, or M9; + and - 30V 300mA 1.0W 12nF 60µH
3051SAL…C… M7, M8, or M9
3051SAL; 3051SAM +, - and CAN 30V 300mA 1.0W 12nF 33µH

Page 1 of 2
SGS Baseefa Limited
Rockhead Business Park
Staden lane, Buxton, Derbyshire
SK17 9RZ
United Kingdom

ANNEX to IECEx BAS 04.0017X Issue No. 0 Date: 2013/04/22

Model Terminals Ui Ii Pi Ci Li
3051SAL…M7, M8, or M9
+ and - 30V 300mA 1.0W 12nF 93µH
3051SAM…M7, M8, or M9
RTD option for 3051SF --- 5V 500mA 0.63W --- ---

The above values for Ci, and Li, for the 3051S FISCO (IA option) are less than those specified for the FISCO Model.

The Remote Mount Meter option (M7, M8, or M9) is for direct connection to the Model 3051S 4-20 mA/HART
Terminals +, - and CAN by a cable whose maximum capacitance and inductance do not exceed 24nF and 60µH
respectively.

The RTD circuit is a separate I.S. circuit, not connected to the Model 3051S Transmitter circuit.

The Model 3051S Wireless Pressure Transmitter is powered by a Model 701PB SmartPower Black Power Module (p/n
00753-9220-0001), covered by Baseefa11ATEX0042X. This battery may be replaced within the hazardous area.

Page 2 of 2

Potrebbero piacerti anche