Sei sulla pagina 1di 4

Alcatel−Lucent Alerts

Alcatel−Lucent has issued the following Proprietary Alert. Further communication to customers is the responsibility of the customer facing
teams.

16−0322 Switch fabric throughput capacity alarms

Type: Informational
Urgency: Medium
Publish Date: 15 Apr 2016
Region: ALL
Expiration: NA
Product category: Carrier Ethernet IP/MPLS & ATM Networks
Product line: Multiservice Core Switching Products
Product: 7450 ESS (Ethernet Service Switch)
Sub−product: ALL
Model: 7450 ESS−12, 7450 ESS−7
Version: 12.0, 13.0, 14.0
Product category: Carrier Ethernet IP/MPLS & ATM Networks
Product line: Multiservice Core Switching Products
Product: 7750 SR (Service Router)
Sub−product: IP, IP Mobile Backhaul, MG − Combo S/PGW, MG − PGW, MG − SGW, MG − WLAN GW
Model: 7750 SR−12, 7750 SR−7
Version: 12.0, 13.0, 14.0

Overview:
SR7/SR12 systems equipped with SFM5 Switch Fabric cards running at 6 Gig Fabric Speed can report switch fabric throughput capacity
alarms.
The alarms are triggered by Switch Fabric Link errors attributed to a sub optimal configuration of the Switch Fabric.

In SROS 12.0R.17, 13.0.R8 and 14.0.R2, a new command is available to optimize the configuration of the Switch Fabric.

This command is exclusively for SFM5 cards running at 6 Gig Fabric Speed.

7950 XRS, 7750 SR−12e (with SFM5) or SR7/12 systems running fabric−speed−b (10 Gig Fabric speed) are not affected.

The new CLI command is: "tools perform system set−trim−mode trim−mode−a(default) or trim−mode−b".

After this command is executed, both SFM5's must be cleared according to the procedure below.

Impact:
Although the alarms are generated, there is no traffic impact unless the line card throughput exceeds the available fabric capacity.

Action To Be Taken:
1) Confirm that the Switch Fabric is running in fabric−speed−a (6 Gig) mode:

*A:IBC−01# show chassis

===============================================================================

16−0322 Alcatel−Lucent Internal Use Only. Do not share with customers. Page 1 of 4
Alcatel−Lucent Alerts

System Information
===============================================================================
Name : ABC−01
Type : 7750 SR−12
−−−− SNIP −−−−
Fabric Speed : 6 Gig <=== Switch Fabric Mode

===============================================================================

2) Verify the state of the Switch Fabric Capacity log events:

show log event−control "chassis" | match Fabric

2104 tmnxEqLowSwitchFabricCap MA sup 0 12


2105 tmnxEqLowSwitchFabricCapClear MA sup 0 12

3) Enable Switch Fabric Capacity logging:

configure log event−control "chassis" 2104 generate

configure log event−control "chassis" 2105 generate

4) Determine which SFM5 has experienced the most degradation.


It should be the first one to be cleared:

show system switch−fabric exclude−sfm 1/or/2

===============================================================================
Switch Fabric
===============================================================================
Slot/Mda Min. Forwarding Capacity Max. Forwarding Capacity
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
1/[1..2] 54% 54%
2/[1..2] 54% 54%
3/[1..2] 54% 54%
4/[1..2] 54% 54%
A 100% 100%
B 100% 100%
===============================================================================

5) CLI command to be executed:

tools perform system set−trim−mode trim−mode−b

clear sfm 1

show sfm and wait until sfm 1 is back in service

clear sfm 2

show sfm and wait until sfm 2 is back in service.

tools dump system trim−mode to verify that the system is in trim−mode−b

16−0322 Alcatel−Lucent Internal Use Only. Do not share with customers. Page 2 of 4
Alcatel−Lucent Alerts

Example of the cli Commands:

A:ABC−01# tools perform system set−trim−mode trim−mode−b


WARNING: CLI Cards and/or SFMs must be cleared for new trim mode to take effect.

*A:ABC−01# /clear sfm 1

*A:ABC−01# show sfm

===============================================================================
SFM Summary
===============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
1 m−sfm5−12 up provisioned <== Wait for the SFM to be back in service.
(not equipped)
2 m−sfm5−12 up up

*A:ABC−01# show sfm

===============================================================================
SFM Summary
===============================================================================
Slot Provisioned Type Admin Operational Comments
Equipped Type (if different) State State
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
1 m−sfm5−12 up up
2 m−sfm5−12 up up
===============================================================================

clear sfm 2

After the SFM is up, verify that the correct trim−mode is enabled:

*A:ABC−01# tools dump system trim−mode

System is set to trim−mode−b


Current trim mode of in service FP3 cards:
==========================================
Slot Card Type Trim Mode
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
1 imm−2pac−fp3 trim−mode−b
2 imm−2pac−fp3 trim−mode−b
3 imm−2pac−fp3 trim−mode−b
4 imm−2pac−fp3 trim−mode−b
A cpm5 trim−mode−b
B cpm5 trim−mode−b
==========================================

Solution Availability:
This issue is resolved in SROS 14.0.R2, 13.0.R8, 12.0R.17 and MG 8.0.R4, 7.0.R13

16−0322 Alcatel−Lucent Internal Use Only. Do not share with customers. Page 3 of 4
Alcatel−Lucent Alerts

Contact:
Nokia Technical Support
Please contact the technical support team for your country.

16−0322 Alcatel−Lucent Internal Use Only. Do not share with customers. Page 4 of 4