Sei sulla pagina 1di 18

Axford Turbine

Consultants LLC
Introducing
Shin Nippon
Machinery Co.

High Efficiency Steam Turbine Generators


• Established in 1951
• Wholly owned subsidiary of
Sumitomo Heavy Industries
• Annual Sales $ 340 million
• 400 Employees
• Capacity to mfg 70 multistage + 100
single stage steam turbines / yr
• KURE
WORKS TOKYO
(HIROSHIMA-KURE) HEAD OFFICE

KURE CITY
• All Steam Turbines made
at SNM factory in Japan.
No mfg outsourcing to
third world.

• Factory at Kure City near


Hiroshima has direct
access to port.

• Equipment loaded for


international export with
no trucking within Japan.

History of Reliable, On-Time Deliveries


Shin Nippon Steam Turbine Deliveries 1970 – 2010

Canada Russia

Poland
Belarus
Germany Slovakia
Romania China
Austria
Bulgaria Uzbekistan
USA TurkeyIran North Korea
Spain Turkmenistan Japan
Korea
Tunisia Iraq
Kuwait Pakistan Thailand Taiwan
Morocco Bahrain Bangladesh
Algeria Egypt
Mexico Cuba Saudi Hong Kong
Qatar India
Dominican Macao
Niger UAE Oman Philippine
Republic Myanmar
Honduras Cambodia
Nicaragua Guiana Vietnam
Barbados Nigeria Sudan Malaysia Brunei
Costa Rica Panama Ghana
Sri Lanka
Trinidad & TobagoLiberia Uganda Singapore
Venezuela
Colombia
Ecuador Indonesia
Tanzania Papua New Guinea
Peru
Brazil Malawi
Australia
Bolivia South Africa
New Caledonia Fiji
Chile

Total Countries::81
Uruguay

Argentina

Total Units: 6,592


Maintenance Shop – Los Angeles
Integrated Turbo Machinery CA

Maintenance Shop - Houston


Sulzer Turbo Services Inc.

35 Steam Turbine Generators


In all regions of USA and Canada
Product Support for Shin Nippon Steam Turbines in the USA
• Full Service Shop near Houston, TX
Since 1972

• Access to Shin Nippon drawings


for major repairs and overhauls

• Tech reps on call 24 / 365

• Warranty, routine maintenance


and emergency service

Convenient for Customers


Shortens the Time for Response
Product Support for Shin Nippon Steam Turbines in the USA
• High Speed Rotor Balancing

• Rotor & Bearing repair

• Component Part Repair

• Manufacture capability for:


- Replacement blades
- Diaphragms
- Labyrinth seals

Full Capability Shop


For Major or Minor Repairs
DRIVEN OUTPUT SPEED
№ MODEL Q'TY END USER COUNTRY YEAR
MACHINE (kW) (RPM)

1 B6-R4-R Generator 1 4000 6686 DAVIS HAMAKUA SUGAR COMPANY USA 198012
2 C10-R9 Generator 1 7500 3600 THEO DAVIES HAMAKUA SUGAR USA 198312
3 C8-R13-ER Generator 1 7165 5021 CHAPLEAU CO-GENERATION Canada 198606
4 B4-R4-R SHRED 1 1866 9055 HAMAKUA SUGAR COMPANY USA 198601
5 C6-R13-ER Generator 1 8030 5795 CHINO CO-GENERATION PROJECT USA 198707
6 C6-R13-ER Generator 1 7950 5795 CAMARILLO STATE HOSPITAL USA 198707
7 C8-R13-AR Generator 1 10500 5005 CARSON CO-GENERATION PLANT USA 198901
8 C8-R14-ER Generator 1 11600 5005 O'BRIEN CALIFORNIA COGENERATION LTD USA 198902
9 C9-R13-R Generator 1 12500 4041 MALETTE KRAFT PULP AND POWER LTD Canada 198905
10 B6-R4-R SHREDE 1 3728 7492 COMMERCIAL & SUGAR CO.,LTD HAWAIIAN USA 198812
11 B6-R7-R Generator 1 9800 5723 EXXON COMPANY U.S.A. SYU PROJECT USA 199103
12 C8-CR15-ER Generator 1 10600 5023 LOS ANGELES COUNTY SANITATION DISTRICT USA 198910
13 C8-R12-ER Generator 1 8000 5021 WATSONVILE CO-GENERATION PROJECT USA 198912
14 C8-R9-ER Generator 1 15400 4985 HAWKER SIDDLEY POWER ENGINEERING INC USA 199004
15 C10-R13-E Generator 1 22000 3600 SOUTH GLENS FALLS COGENE USA 199011
16 C10-R13-E Generator 1 22000 3600 CARTHAGE COGENERATION USA 199011
17 C6-R13-ER Generator 1 7535 5800 AGNEWS STATE HOSPITAL USA 199007
18 C9-R12-ER Generator 1 14500 4200 UCLA COGENERATION CHILLER PLANT USA 199210

North American Installations – Sheet 1 of 2


DRIVEN OUTPUT SPEED
№ MODEL Q'TY END USER COUNTRY YEAR
MACHINE (kW) (RPM)
19 C8-R12-ER Generator 1 10500 5000 ICE FLOE COGENERATION PROJECT USA 199407
20 C9-R15-ER Generator 1 25600 4900 CANADIAN GAS & ELECTRIC INC Canada 200209
21 C8-R12-R Generator 1 8475 6194 CITY OF CORONA USA 200307
22 B8-R8-ER Generator 1 25000 4200 WHITE MOUNTAIN ENERGY, LLC USA 200311
23 C6-R9-ER Generator 1 8700 7800 COUNTY SANITATION DISTRICTS OF LOS ANGELES COUNTY USA 200510
24 B8-R4-ER Generator 1 14210 5000 BETHEL ENERGY LLC USA 200909
25 C10-R10-EX Generator 1 38690 3600 BETHEL ENERGY LLC USA 200909
26 C11-R16-EX Generator 1 67000 3600 SUN COKE COMPANY USA 200803
27 C9-R12-ER Generator 1 25000 4200 BULL MOOSE ENERGY LLC USA
28 C10-R15-EX Generator 1 39200 3600 WESTERN WATER AND POWER LIMITED, LLC USA
29 B6-R8-ER Generator 1 9300 5300 PRATT INDUSTRIES (USA) MILL DIVISION CONYERS USA 200808
30 B6-R3-R Generator 1 8500 6500 THOROLD COGEN, L.P Canada 200903
31 C11-R13-EX Generator 1 48000 3600 ZELLSTOFF CELGAR LIMITED PARTNERSHIP Canada 200909
32 C11-R16-EX Generator 1 67000 3600 SUN COKE COMPANY USA 200903
33 C11-R12-EX Generator 1 60000 3600 VISION POWER SYSTEMS, INC. USA 999912
34 C10-R14-ARX Generator 1 28000 4300 FORT NELSON GENERATING STATION Canada 201101
35 C11-R16-EX Generator 1 67000 3600 FITZGERALD RENEWABLE ENERGY, LLC. USA 201010

North American Installations – Sheet 2 of 2


Product Design & Capabilities
• Inlet Steam Conditions
– Up To 130 Bar (1850 PSI)
– Up To 550℃ (1022 F)

• Exhaust Steam Conditions


– Condensing or Back Pressure

• Output & Speed


– 1Kw To 80,000 Kw
– Direct Drive or Geared

Impulse Blading
Reduces Performance Loss Over Time
Steam Turbine Models B = Backpressure
& Exhaust Configurations C = Condensing
Direction of Exhaust Outlet OUTPUT (MW)
Model
Axial Down Up Side 20 40 60 80 100
B4 ○ ○ ○
B5 ○ ○ ○
B6 ○ ○ ○
B8 ○ ○
B10 ○ ○
C4 ○ ○
C5 ○ ○
C6 ○ ○ ○
C7 ○ ○ ○
C8 ○ ○ ○
C9 ○ ○ ○
C10 ○ ○
C11 ○ ○
Axial Exhaust vs. Down Exhaust

Down Exhaust
Steam Turbine on Mezzanine

Condenser

Axial Exhaust
Steam Turbine & Condenser
at same level
Sun Coke Corporation
Haverhill, Ohio Typical Axial Exhaust
Installation
• Model C11-R16-EX

• 67,000 kW Brush Generator

• 3600 RPM – Direct Drive

• Inlet 1555 psia x 1000 F

• Woodward Sliding Pressure


Controls

• Exhaust 1.35 psia ( 2.7” Hga)

• 2 Bleed Extractions
The Axial Exhaust Advantage
Steam Turbine & Condenser
at same level

Efficiency Improvement - Reduces Steam Turbine Exhaust Loss

Cost Reduction – Reduces building height and size of foundations

Quicker Installation – Far less site labor required

Shin Nippon Models Available with Axial Exhaust


No Additional Price or Delivery
• Woodward digital governor for all steam flow

• Allen Bradley PLC –overall control & data management

• Most reliable vendors for control systems

• Excellent product support in USA & worldwide

Because Customers do not like


OEM Proprietary Controls
Shin Nippon Factory Testing
• Every turbine tested
at no-load, 100% rpm

• Contract Controls
Utilized for shop test

• Live Steam Checks


on Casing and Sealing

Reduces Surprises at Jobsite


Shin Nippon = Your Best Choice
1 to 80 MW Steam Turbine Gensets
• 60 Years of Experience
• High Efficiency Design
• Axial Exhaust Configuration
• Direct Drive for most applications
• History of On-Time Shipment

Competitive Price & Delivery

Potrebbero piacerti anche