Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
klaus.ciriano@detnov.com
1
We provide
Company presentation
Addressable systems
Conventional systems
Special detectors
2
Product Range
Conventional Addressable
CO detection Extinguishing
3
Company
Presentation
4
Who we are?
Own design
Own fabrication
5
European companies of the Group
6
Detnov international presence
(+50 countries)
7
Our facilities
https://www.youtube.com/watch?v=bQZgyLi93Cs
8
Benefits of our products
• Nice design
• User friendly
• Easy to be installed and commisioned.
• EN54, CNBOP, Middle East Civil Defense
approvals (UAE, Qatar, Kuwait, Saudi
Arabia, Pakistan, India, Iran, Jordan, Iraq,
Bahrein).
• Competitive price
9
Verticals were our products are
installed
Hotel / Residential Industries Shopping malls
10
Some of our references
• Hotel & Spa Golden Bahía (Girona,Spain)
• Hotel Best Western (Tarragona,Spain)
• Premium Business Center (Lithuania)
• Police Station Brcko (Bosnia)
• Mango Logistic Center (Barcelona,Spain)
• Naghsh-e Jahan Stadium (Isfahan, Irán)
• Aurum Club Marmara (Turkey)
• Yazaki factory (Šabac, Serbia)
• Vlatacom R&D Center (Serbia)
• IQS University (Barcelona,Spain)
• Azel Kule Apartments (Turkey)
• Ikea Parking (Valencia, Spain)
• Bauhaus Parking (Mallorca, Spain)
• National Children's Specialized Hospital
"Okhmatdyt" (Kiev, Ukraine)
• Viļānu high school (Viļānu, Latvia)
• Rehabilitation Centre for Physically Disabled
People (MEREK) (Budapest, Hungary)
11
National Children's Specialized Hospital
"OKHMATDYT", Kiev, Ukraine
12 x CAD-150-8 Plus networked with
graphical software SGD + RAD-150 +
10 x CCD-103 with 10 x TPLD-100 +
7083 detectors + 170 MCP + 1158
modules
CMD-103 + 20 DMDP-500
(http://ohmatdyt.com.ua/)
12
Associations and Exhibitions
13
https://www.youtube.com/watch?v=uOZJVGTFSew
Addressable
system
14
Available addressable CAD-150
control panels
• 250 addresses per loop, without any limitation for the connexion of
any type of device into the same loop ( detectors, call points, … )
• Conventional and Extinguishing panels can be connected directly into
the loop.
• Devices without polarity unless built-in isolators are present.
• Tested loop length up to 2 kms.
• Every panel :
250 zones
1024 manouvers + 10 logical ones
16
Addressable Control Panels
Features
Up to 32 control panels or
repeaters in a bus or loop network
configuration
Up to 1 Km distance between
them if copper wire used.
18
Addressable control panel
graphical repeater
RTD-150E
RTD-150T
Intuitiv interface
Ethernet
Elegant design HDMI
Graphic management
Unlimited nº repeaters RTD-150W
20
PC graphical software – SGD-151
• Supervision and management of one or several fire
alarm systems based on CAD-150 panels through PC
graphic environment.
• Compatible with Windows 8 or newer versions.
• Simple,
intuitive
and user-
friendly.
• Mapping
display
integrated.
• 5 users + 1
server 21
Voice evacuation
Compatible with our full CAD-150 addressable fire panels range and
integrated by means of RS485
22
Addressable detectors
26
Addressable sounders & beacons
Addressable sounders :
MAD-461-I & MAD-464-I sounder & isolator
MAD-465-I & MAD-467-I sounder, beacon & isolator
27
Programming tool PGD-200
In case all the loop devices are with isolator they can also be addressed
by the fire panel autoaddressing function.
28
Configuration software
29
Analog USB Monitor Software
30
Conventional
systems
31
Conventional control panels CCD-000
CCD-020 / CCD-040
34
Conventional accesories
Manual call points Sirens
35
Connection example
RELAY OUTPUT EOL R.
ALARM & FAULT 4K7
OUTDOOR SOUNDER
OUTPUT
EOL R.
4K7
EOL R. CONFIGURABLE
4K7 EXTERNAL INPUT
SOUNDERS DELAY
36
Expansion cards
37
Alarm and failure communication
card TPLD-100
Detnov convencional(s) fire alarm
panel(s) can be integrated within an
addressable Detnov loop without
modules, enriching the
communication.
Conventional
panel
39
Modbus communication expansion card
TMD-100
42
Extinguishing system CCD-103
One output for the activation of the bottle and one for the warning sign.
2 inputs for the bottle surveillance: pressure and one for the flow
Working modes for the extinguishing block:
Manual, automatic and y abort.
Two sounder outputs for the indication of the extinguishing states.:
Pre-activated y activated.
Configurable extinguishing delay on board.
Two inputs for the area’s surveillance: one for the door and one for the fan.
Event and configuration history register.
Three MCP inputs: start, stop and hold.
43
Connection
CCD-103 panel
45
Configuration software
46
Special
detectors
47
IR beam detector
48
IR beam detector low level controller
It allows making any changes or adjustaments in the beam from ground level, as :
• Beam detector commissioning.
• Beam head movement.
• View the air quality.
• View the beam status.
• Change sensitivity thresholds.
• Make the alarm latching or not latching.
• See fire and fault counts.
• Complete a self test.
• Turn the beam on and off.
• Adjust output and receiver settings.
• Monitor the beam temperature.
• See how many compensation has been made for dirt build up.
49
Autonomous detectors
Self resettable.
Test button.
Up to 10 devices in a network
Calypso-II Calypso-II-R
Isolated detector Networked
detectors
50
Autonomous detectors
complementary devices
51
CO detection for
Parkings
52
CO detection panels
Panels expandable from 1 to 3 zones using the same
casing.
No polarity
Compact (antivandalism
DMD-500 IP65) DMDP-500
54
Fan speed control cards
55
Smart fan regulation
Energy Saving
Supplied by Detnov Not supplied by Detnov
TRMD-501 card
Inverter 1
Fan 1
Scada Software
SGD-150
CO Panel Inverter 2 Fan 2
56
Some of our new
developments
57
CAD-250 addressable panel (Vesta)
58
CAD-250 addressable panel (Vesta)
New addressable fire detection panel with:
• From 2 up to 32 loops.
• 10” touchscreen.
• Up to 64 networked panels.
• Compatible with all Detnov loop devices but not with CAD-150 panels
• Integration with BMS and in the near future with SGD-151 graphical
software.
• 250 devices per loop to be grouped in up to 2048 zones and 250 areas per
panel and 1024 groups per system.
• 100.000 event log positions per panel.
• 25.000 programmable manoeuvres.
• Main & Reserve possibility.
59
CAD-250 addressable panel
60
Communication card – TMB-251/252
• Outputs:
• 1 Ethernet port Graphical
software
• 1 Network panel RS-485 port
Connectivity
• 2 Modbus RS-485 outputs
Remote control
• 1 RS-232 serial port
• Up to 64 network panels
• Compatible with CAD-150*
* Not compatible with TRED-150
45
LPCB product range
62
www.detnov.com
Follow us on:
63