Abbreviation Description Remarks

P1RHI 1ry RH Inlet Steam Pressure


T1RHI 1ry RH Inlet Steam Temperature
T1RHO 1ry RH Outlet Steam Temperature
T1SO 1ry SH Outlet Steam Temperature
T2RHO 2ry RH Outlet Steam Temperature
T2SI 2ry SH Inlet Steam Temperature
T2SO 2ry SH Outlet Steam Temperature
2IS 2ry SH Spray
T3SI 3ry SH Inlet Steam Temperature
T3SO 3ry SH Outlet Steam Temperature
3IS 3ry SH Spray
AF Air Flow
AH Air Pre-Heater
AI Analog Input
AM Analog Memory
AO Analog Output
APC Automatic Plant Control System
APS Automatic Plant Start-up/Shut-down System
BCP Boiler Circulation Pump
EC Boiler Extraction Valve
BFP Boiler Feed Water Pump
BF Boiler Follow
BI Boiler Input
BID Boiler Input Demand
BIR Boiler Input Rate
BM Boiler Manual
FBRC Boiler Re-circulation Flow
BR Boiler Re-circulation Flow Control Valve
B-SEQ Boiler Sequence Control System
BNR. Burner
BT Burner Tilting
CRT Cathode Ray Tube
CPU Central Processing Unit
CCF Circular Corner Firing
CF Coal Feeder Coal Flow
CAD Cold Air Damper
COND. Condenser
CONT. Control
CV Control Valve
CC Coordinate Control
DAS Data Acquisition System
DEC Decrease
DSH De-superheater
DEH Digital Electric/Hydraulic Governor Control System
DCS Distributed Control System
ECO Economizer
EP Electric Precipitator
ELEV. Elevation
FAIL. Failure
Abbreviation Description Remarks
FFDF FDF Air Flow (Volume)
FW Feed Water
FWF Feed Water Flow
FWF MW Feed Water Flow for BID
TFSI Final SH Inlet Steam Temperature
TFSO Final SH Outlet Steam Temperature
F Flow
FRC Flow Re-circulation
FDF Forced Draft Fan
FF Fuel Flow
FFD Fuel Flow Demand
FRD Fuel Flow Demand without Cross Limit Function
FX Function Generator
GD Gas Damper
GEN. Generator
GV Governor Valve
HDR. Header
HP High Pressure
HAD Hot Air Damper
HAG Hot Air Gate
FIDF IDF Gas Flow (Volume)
INC Increase
IDF Induced Draft Fan
ICV IP Control Valve
LH Left Hand
L.O. Light Oil
FLO Light Oil Flow
PLO Light Oil Header Pressure
LDWDT Load Change Width
LD Load Demand
LDD Load Demand (Delay)
LDR Load Rate
LP Low Pressure
TP Main Steam Pressure
TPD Main Steam Pressure Set
MFT Master Fuel Trip
MAX. Maximum
MW Megawatt
MWD Megawatt Demand
MBC Mill Burner Control System
MIN. Minimum
M Motor
NLDC National Load Dispatch Center
OPS Operator Station
OUT Outlet
POS. Position
PRESS. Pressure
P Pressure
PCV Pressure Control Valve
Abbreviation Description Remarks
PAF Primary Air Fan
PF Primary Air Flow
RSV Reheat Stop Valve
RH Re-heater
RH Right Hand
SG Signal Generator
SA Standby Auto
SF Steam Flow
SHRWSO Superheat Rate of Water Separator Outlet
SHRWWO Superheat Rate of Water Wall Outlet
SH Super-Heater
SWGR Switch-gear
SYNC. Synchronize
TEMP. Temperature
T Temperature
TDWO Time Delay Wipe Out
FA Total Air Flow
FCF Total Coal Flow
TFF Total Fuel Flow
T Transfer Relay(Simple Analog Switch)
T Turbine
TB Turbine Bypass
TF Turbine Follow
MSV Turbine Main Stop Valve
V/V Valve
V.H. Very Hot
VDU Visual Display Unit
WS Water Separator
WSDT Water Separator Drain Tank
WDC Water Separator Drain Tank Level Control Valve
FWSIJ Water Separator Injection Flow
PWS Water Separator Outlet Pressure
TWSO Water Separator Outlet Steam Temperature
WW Water Wall
TWWO Water Wall Outlet Steam Temperature
WFR Water/Fuel Ratio
WFR LL WFR Lower Limit
WB Wind Box
TSAT WS Saturated Temperature
SVIC Supervisory Instrument and Control
BMA Boiler Monitoring for Analytical
FIDF Induced Draft Fan Flow
CD Control Damper
DT Differencial Transmitter
WID   Width
WET Wet
DRY Dry
DEVI Deviation
WSI Water Separator Inlet
Abbreviation Description Remarks