Sei sulla pagina 1di 4

COMPARATIVE ANALYSIS OF PD 957 & BP 220

PARAMETER PD 957 BP 220 BP 220


OPEN MARKET HOUSING ECONOMIC HOUSING SOCIALIZED HOUSING

1. MAXIMUM SELLING PRICE

2. PROJECT LOCATION

3. LAND LOCATION
(Percentage of Gross Area
one hectare & above)

a. Saleable Area
b. Non-Saleable Area

b.1 Areas allocated for Parks Mandatory Allocation for Parks and Playgrounds Per Tabulations Below
& Playgrounds (1 Hectare
& above)

NOTE: In no case shall the Area be less than 100 square meters

Mandatory Allocation for Parks and Playgrounds Per Tabulations Below


b.2 Area allocated for Variable Density (No. of Lots and/or Living % of Project Gross Area
Community Facilities Units Per Hectare)

b.3 Circulation System

4. MINIMUM LOT AREAS

Single Detached
Single Attached / Duplex /
Semi-Detached
Rowhouse
NOTE: 1. Saleable lots designated as duplex and/or rowhouse lots shall
be provided with housing components
2. Maintain a 60, 40 ratio for house and lot where 60% for the
house and 40% for the lot (selling price for house&lot package)
PARAMETER PD 957 BP 220 BP 220
OPEN MARKET HOUSING ECONOMIC HOUSING SOCIALIZED HOUSING

5. MINIMUM LOT FRONTAGE


5.1 SINGLE DETACHED
a. corner lot
b. regular lot
c. irregular lot
d. interior lot

5.2 DUPLEX / SINGLE


ATTACHED / SEMI
DETACHED
5.3 ROWHOUSE

6. LENGTH OF BLOCK

NOTE: for ROWHOUSES, there shall be a maximum of 20 UNITS but in no case shall be more than 100m in length

7. ROADS RIGHT OF WAY (ROW) ROW CARRIEGEWAY ROW CARRIEGEWAY ROW CARRIEGEWAY

7.1 Major
7.2 Minor
7.3 Motorcourt (Cul de sac,
branch, loop, Tee

7.4 Alley
7.5 Footpath / Pathwalk
7.6 ROW of access to
interior lot

+ Right of way (ROW) of major roads shall be increased as project size increases. ROW shall not be lower than ROW of public road.
+ Major Roads shall maintain a uniform width of road right of way. Tapering of road width shall not be allowed

NOTE: 1. Interior subdivision project must secure right of way to the nearest public road
2. Subdivision projects with direct access to a main public road must provide sufficient setback to accommodate loading and unloading
of passengers.
3. Subdivision project shall provide provision for future expansion (see text)

8. MAXIMUM SIZES OF PROJECT


PER HIERARCHY ROADS

Project Size Range

2.5 hectares and below

Above 2.5 - 5 hectares


Above 10 - 15 hectares
Above 15 - 30 hectares
Above 30 hectares
PARAMETER PD 957 BP 220 BP 220
OPEN MARKET HOUSING ECONOMIC HOUSING SOCIALIZED HOUSING

9. ROAD SPECIFICATIONS

9.1 Planting Strip (PS)


Sidewalk (SW)

a. Major Road (each side)


b. Minor Road

NOTE: refer to supplemental rules and regulations to implement PD 963 (HLURB A.O. no. 2 series of 1994 (12 April)

9.2 Road Pavement Developed Area Under Developed Developed Area Under Developed
Area Area
a. Major Road
b. Minor Road
c. Motor Court
d. Sidewalks
e. Alley

+ Under Developed Areas- Characterized by the predominant absence of


utility systems or networks, especially water supply, roads & power

+ Developed Areas- Characterized by the predominant presenve of utility


systems or networks especially water supply, roads and power

10. WATER SUPPLY Developed Area Under Developed Developed Area Under Developed
Area Area

NOTE: Each subdivision must have at least an operational deepwell and pump sets with sufficient capacity to
provide ADO, provided a spare pump and motor set is reserved

10.1 Minimum Water Supply


Requirements

10.2 Fire Protection Provision for Fire Protection shall comply with the requirements of the National Fire Protection Code (PD 1185)

11. DRAINAGE SYSTEM

+ The drainage system must conform with the natural drainage pattern of the subdivision site, and shall drain
into appropriate water bodies, public drainage system or natural outfalls.
PARAMETER PD 957 BP 220 BP 220
OPEN MARKET HOUSING ECONOMIC HOUSING SOCIALIZED HOUSING

12. SEWAGE DISPOSAL


SYSTEM

12.1 Septic Tank

12.2 Connection to Community Whenever possible, connections shall be made to an approved public or community sewer system subject to the
Sewer System requirements and provisions of the Sanitation Code and other applicable rules and regulations with regards to
materials and installation practices.

13. POWER SUPPLY Developed Areas Under Developed Areas

Installation practices, materials and fixtures used shall be in accordance with the provision of the Electrical Code
and local utility company.

14. GARBAGE DISPOSAL

15. SHELTER COMPONENT

a. Minimum Floor Area

a.1 Single-Detached

a.2 Duplex
a.3 Rowhouse

NOTE: Minimum floor area shall be in one floor level exclusive of mezzanine
floor if any.

b. Mnimum Level of
Completion

b.1 Single-Detached
b.1 Duplex
b.3 Rowhouse

NOTE: Minimum floor area shall be in one floor level exclusive of mezzanine
floor if any.

16. SETBACKS / EASEMENTS

a. FRONT
b. SIDE
c. REAR
d. ABUTMENTS May be allowed per requirements of the National Building Code (PD 1096)

Potrebbero piacerti anche