Manufacturing Expertise 4
Steel: The Material of Choice 6
Highland Tank Sets the Standard 8
Working Together for a Cleaner
Environment 11
Aboveground Tanks 13
Fireguard ®
14
Fireguard , p. 14
® Aviation Fueling Systems 19
UL-142 ®
20
Barrel Tanks 22
OP Tanks 24
Dike Tanks 25
Flameshield ®
25
Horizontal Tank Specifications 26
Vertical Tank Specifications 28
Vertical UL-142 , p. 20
® Lube Tanks 30
Hopper Tanks 32
Bulk Storage Drums 34
ToughTanks 35
LPG Vessels 37
Underground Tanks 41
HighGuard 42
TITAN ®
44
LPG Vessels, p. 37 HotShot 46
STI Technologies
®
48
ACT-100-U Tanks ®
49
STI-P3 Tanks
®
49
Underground Tank Options
and Specifications 52
Accessories 55
Our Commitment to You 70
TITAN®, p. 44
www.highlandtank.com • 3
Manufacturing Expertise
Experience Quality Assurance
Since 1946, Highland Tank All of our products are backed by our
has been upholding a tradition of helpful support staff to ensure quality
uncompromising craftsmanship and throughout every phase of your project.
a commitment to providing solutions Highland’s team of professionals in
to even the most challenging storage design, engineering, fabrication, sales,
tank projects making Highland Tank delivery and service provide you
the leader in the steel tank industry. with outstanding solutions for your
Engineering depth, state-of-the-art liquid storage challenges. Our
equipment and skilled craftsmen goods undergo strict quality control
with pride and traditional American processes and are readily available
work ethic have given us the tools from our national distribution network
needed to maintain our dedication and six manufacturing facilities.
to quality production.
Manufacturing area:
Capability, Capacity, Commitment 296,000 ft2 at six locations
Highland Tank has facilities strategically
located to serve our core markets in Maximum Physical Fabrication Size:
the United States. Our team works with Horizontal tanks: 70,000 gallons
the proper tools and latest technology Vertical tanks: 57,500 gallons
to help build the highly customized ASME pressure vessels: 60,000 gallons
products required in today’s world. Maximum diameter: 14'
Steps are constantly being taken to Maximum length: 90'
keep Highland Tank on the cutting Steel rolling: up to 1.25" thick
edge. Even in economic times when
many companies are cutting back Product Transportation:
and downsizing, Highland Tank is Highland Tank takes product delivery
committed to our clients. A new facility, seriously. We have our own fleet of
which will allow us to build larger, trucks and team of experienced drivers.
heavier tanks and vessels that are in Your product will be in the hands
demand, is set to open in 2013. This of people who transport over-sized
new facility is just one more reason loads every day, taking pride in timely
why Highland Tank remains the leader delivery and providing Highland’s
in steel tank manufacturing. signature service.
4 • www.highlandtank.com
5
Steel: The Material of Choice
Superior Structual Strength
Contemporary steel-making
technology enables stainless steel to
be welded and fabricated as readily
as conventional steels. Additionally,
stainless steel has many unique
properties that may make it the best
choice for your special storage
tank requirements.
Advantages
The bright, easily maintained surface
of stainless steel provides a clean,
contemporary appearance. Stainless
steel is corrosion-resistant to a large
number of liquids. Stainless steel is
used when carbon steel or internal
linings are not compatible with the
product to be stored.
Outer
Thermoplastic
Tank
TITAN
®
®
8 • www.highlandtank.com
The Ultimate Protection Unique Secondary Containment Performance Coatings
(DW UL-2085) (DW UL-1746) Proper surface preparation is an
Fireguard® fire-protected tanks are The inner tank is constructed similarly important factor in any successful
cylindrical or rectangular double-wall to a UL-58 single-wall steel tank, coating or lining. Quality assurance
aboveground tanks. The exterior steel but the outer thermoplastic tank is is maintained through Highland’s
wall provides superior weatherability made from a high molecular weight complete in-house grit blast cleaning,
and low-cost maintenance. The polymer creating a tough, economical finishing and curing facilities. Our
interstice, a minimum of 3" around the double-wall tank. The interstice facilities are temperature-controlled for
inner tank, is filled with a lightweight design assures fluid migration to the year-round application. Only qualified
material which provides thermal monitoring system. This innovative tank and experienced personnel, working
insulation for a 2-hour minimum technology is Highland Tank’s under stringent guidelines, spray applied
fire rating. own TITAN®. high-performance formulations, including
epoxies and high-build polyurethanes.
Both inner and outer tanks can be Factory Testing Exterior coatings and interior linings are
tightness tested and are equipped with A 5 PSI factory air test and seam selected to meet specific site conditions
emergency vent fittings. Our Fireguard® inspection is conducted on every and service requirements.
tanks meet or exceed required storage tank. All underground
standards for protected, insulated, double-wall storage tanks are shipped Highland Tank and Steel Tank
fire-rated storage tanks. with a vacuum on the interstice for Institute specifications are followed
continuous testing to guarantee to assure complete internal and external
integrity of both the primary and corrosion protection.
secondary tanks.
9
10
Working Together for a
Cleaner Environment
Environmental protection is one of Responsible Manufacturing
our highest priorities. How we impact Reducing the environmental impact
the environment is important to us, of our products starts with the product
and environmental considerations are design phase. Design dictates the
an integral part of Highland Tank’s quantity and type of raw materials
business practices. The steps we used, recyclability of materials
take today to preserve our planet will and energy consumption required
ultimately affect the health and for manufacturing.
well-being of our children. From the
earliest stages of product design Today, environmental issues are
through manufacturing, recycling important criteria for material selection.
and usage, we take care to keep All of our steel tank products are 100%
our activities and our products recyclable after use. Although recycling
environmentally sound. Our progressive is important, we don’t stop there.
thinking, inventive policies and Highland Tank works hard to gather
pioneering spirit are helping to make and recycle our waste steel at all of our
the world a greener, cleaner place for factories during and after production.
our children.
Also, our decision to reduce the use
Product Design of VOC-laden paints and completely
It all begins with the design and eliminate the use of solvent-rich
manufacturing of tank products fiberglass reinforced polyester
specifically required to safely store makes our product line much more
some of the most hazardous materials. environmentally friendly than our
Our company produces the industry’s counterparts. Highland Tank helps to
most robust tank products for the safeguard the environment — as well
safe storage of petroleum, chemicals as consumers’ safety — by restricting
and other hazardous materials to the use of these environmentally
ensure compliance with all applicable harmful compounds in our materials
regulatory requirements. As a result, and manufacturing processes.
our tank products are the number one
choice among industry professionals.
www.highlandtank.com • 11
12 • Highland Tank | Propane
Aboveground Tanks
Innovations in Steel Tank Design and Technology
Highland Tank’s aboveground tanks are of the highest quality to ensure compliance
with the U.S. EPA’s regulations for aboveground tanks for the storage of petroleum
and chemicals. Primarily designed for safe storage of flammable and combustible
liquids, our aboveground tanks are available in a variety of industry-proven
cylindrical, rectangular, single-wall, double-wall and fire rated designs.
Exterior full fillet lap joints for added A variety of tank support and
“ribbed” strength hold-down systems
14 • www.highlandtank.com
Dramatic developments in tank design during the past decade have seen the
emergence of fire-rated, insulated, aboveground storage tanks for the safe storage
and dispensing of motor fuels and other flammable and combustible liquids.
15
Fireguard Design Options
®
Interstitial
Monitoring
Pipe Overfill
Prevention
Valve
Drop Tube
Tank Saddles
Return Line
Supply
Line
Remote Fill
Containment
Product
Dispenser
Aviation Refueling
Check Valve
Pump &
Filtration
Module Evacuation
Pump
Floating
Suction
Fireguard® Tank as part of a Modular System with Pump and Filtration Module
This set-up would include an additional module(s) for Direct-to-Plane, Truck Load or Remote Dispensing.
A specific application at a military or commercial installation would dictate engineered fueling systems.
www.highlandtank.com • 17
Fireguard Sizing Chart
®
Cylindrical
Volume Inner Tank Outer Tank
(Gallons) Diameter Length Diameter Overall Height Length
300 3'-2" 5'-0" 4'-2" 5'-0" 6'-0"
500 4'-0" 5'-5" 4'-6" 5'-4" 6'-0"
1,000 4'-0" 10'-9" 4'-6" 5'-4" 11'-4"
1,000 5'-4" 6'-0" 5'-10" 6'-8" 6'-7"
2,000 5'-4" 12'-0" 5'-10" 6'-8" 12'-7"
3,000 5'-4" 18'-0" 5'-10" 6'-8" 18'-7"
4,000 5'-4" 24'-0" 5'-10" 6'-8" 24'-7"
4,000 8'-0" 10'-8" 8'-6" 9'-4" 11'-3"
5,000 8'-0" 13'-4" 8'-6" 9'-4" 13'-11"
6,000 8'-0" 16'-0" 8'-6" 9'-4" 16'-7"
8,000 8'-0" 21'-4" 8'-6" 9'-4" 21'-11"
10,000 8'-0" 26'-8" 8'-6" 9'-4" 27'-3"
12,000 8'-0" 32'-0" 8'-6" 9'-4" 32'-7"
15,000 10'-0" 25'-6" 10'-6" 11'-4" 27'-1"
20,000 10'-0" 34'-0" 10'-6" 11'-4" 34'-7"
25,000 10'-0" 42'-7" 10'-6" 11'-4" 43'-2"
30,000 10'-0" 51'-2" 10'-6" 11'-4" 51'-9"
40,000 11'-6" 51'-6" 12'-0" 13'-0" 52'-1"
50,000 12'-0" 59'-2" 12'-6" 13'-6" 59'-8"
60,000 13'-0" 60'-6" 13'-6" 14'-6" 61'-0"
Rectangular
Volume
(Gallons) Width Height Length Width Overall Height Length
500 3'-0" 3'-0" 7'-6" 4'-0" 4'-6" 8'-6"
1,000 4'-8" 3'-0" 9'-8" 5'-2" 4'-1" 10'-3"
2,000 6'-4" 4'-0" 10'-8" 6'-10" 5'-1" 11'-4"
3,000 5'-5" 5'-5" 13'-8" 5'-11" 6'-5" 14'-3"
4,000 5'-5" 5'-5" 18'-2" 5'-11" 6'-5" 18'-9"
5,000 5'-5" 5'-5" 22'-9" 5'-11" 6'-5" 23'-4"
6,000 10'-10" 5'-5" 13'-8" 11'-4" 6'-5" 14'-3"
6,000 5'-5" 5'-5" 27'-4" 5'-11" 6'-5" 27'-11"
8,000 10'-10" 5'-5" 18'-2" 11'-4" 6'-5" 18'-9"
10,000 10'-10" 5'-5" 22'-10" 11'-4" 6'-5" 23'-5"
12,000 10'-10" 5'-5" 27'-4" 11'-4" 6'-5" 27'-11"
Overall
Height
Aviation refueling is a challenging task Our SAFE systems product line We also offer a Remote Dispensing
due to many critical safety concerns. features several modules that can Module (RDS). This unit is commonly
Highland Tank now offers Self- be combined to provide a solution used when refueling activities are
contained Aviation Fuel Equipment for a wide variety of aviation fueling located remotely from the fuel storage
(SAFE) systems. Our team of scenarios. Included in the line is tank. Rooftop helicopter refueling at
professionals has the expertise to offer a Pump and Filtration module (PFT), hospitals, offshore drilling rigs and
precision-engineered, modular fueling which is critical for assuring clean airborne law enforcement agencies
systems to accompany our tanks on fuel from the delivery truck to storage often entail the supply of a remote RDS
military and commercial installations. to dispensing. Module in addition to a PFT Module
back at the storage tank.
These module configurations A Direct-to-Plane module (DTP)
simplify specification, procurement, allows for fueling at many private or Highland’s Aviation Fueling Systems
maintenance and spare parts support. executive airfields where planes are are typically paired with a Fireguard®
Each module is precision engineered fueled at the storage tank. The DTP or Flameshield tank depending on
with rugged, field-proven components Module can be designed for overwing setback, regulations and other site-
to provide years of trouble-free and/or underwing refueling. Highland specific requirements. Highland
service. The flexible, modular design also offers a Truck Loading Module Tank and its team of Aviation Fueling
of the SAFE systems allow for system (TLO), which is typically needed at Specialists will work with you to provide
expansion as needs change by simply larger aviation facilities where planes a turnkey solution.
adding modules. Highland Tank now must be fueled on the tarmac by a
offers a truly scalable aviation fueling refuel truck.
system solution.
www.highlandtank.com • 19
UL-142 Tanks
®
20 • www.highlandtank.com
21
Barrel Tanks
Highland Tank barrel tanks are the ideal robust tank that allows for the mobility Standard Tank Features
solution for storage of a wide variety and flexibility required in the tough Mild carbon steel construction
of production liquids while using the natural gas drilling industry.
UL-142® label
least amount of valuable real estate.
They are fabricated under Highland’s With our reputation for unmatched Capacity from 90-500 barrels
strict quality control procedures to quality and service, Highland Tank Exterior-full fillet lap joints for added
industry standards for the safe storage makes sure these barrel tanks are “ribbed” strength
of produced water, crude oil and worker safe. Our OSHA-compliant
Seam inspection and 5 psi factory
other liquids commonly handled and fixed ladder and cable-climbing
air test
stored by natural gas exploration and system includes all of the necessary
production companies. components for fall protection when Nozzle fittings per schedule
accessing the rooftop vents, manways Cleanout manway with cover
Highland Tank also offers a premium and hatches for periodic inspection and
Pressure vacuum vent
Gas & Oil Field Tank design that takes maintenance. And with our optional
(thief hatch)
the barrel tank to a whole new level. 100% double-wall construction,
Our stronger lap-weld construction Highland Tank helps the drilling industry Lifting lugs
and heavy-duty polyurethane coatings comply with environmental regulations, Primer paint
inside and out result in a stronger, which are often more stringent in
longer-lasting tank. Couple that with unconventional gas regions such as the
a custom L-shaped skid, and you’ve Marcellus and Utica Shale areas.
got the “ultimate” barrel tank – a more
22 • www.highlandtank.com
23
OP Tanks
OP-Chamber
The Overfill Protector Primary Tank
Pumpout Port E-Vent
with Plug
Secondary Tank
Normal Vent Overfill Protector
Support Saddles
Supply Line with
Suction Drop Tube Product
Level Sensor Dispenser
OP Chamber
Concrete
Support Pad
Safety Bollards
as Required
24 • www.highlandtank.com
Dike Tanks
Standard and AREO
Flameshield
®
www.highlandtank.com • 25
Selecting & Specifying Horizontal, Dike, AREO and OP Tanks
P
L
Q N
J
O
Q
M Z Y Z G H E Lifting Lug
Fireguard
®
N
Double-wall
Double-wall Steel Outer Tank
Steel Outer tank or Aluminum Batt
Steel & Skin External C I F
Inner Insulation System Double-wall R
Interstitial V
Tank S
Monitoring Pipes
A W
D
X U
T
S
B
N C
F
G
F VW I F
G
C
E K J
F
O M
Q
B U
R
Shell Height
T
S K J P
H
D
L
A Tank Diameter
28 • www.highlandtank.com
Vertical Tank Sizing Guide
Volume Dimensions
Optional Fittings as Required Gallons Diameter Shell Height
Optional Step-off 185 3'-2" 3'-4"
Access Platform
with Railing 240 3'-2" 4'-0"
300 3'-2" 5'-0"
500 4'-0" 5'-5"
1,000 4'-0" 10'-9"
1,000 5'-4" 6'-0"
1,500 5'-4" 9'-0"
2,000 5'-4" 12'-0"
Tank Anchoring System
3,000 5'-4" 18'-0"
OSHA Design 4,000 8'-0" 10'-6"
Ladder Safety Cage
(Required above 20') 5,000 8'-0" 13'-4"
6,000 8'-0" 16'-0"
8,000 10'-0" 14'-0"
Optional Hinged Lid
10,000 10'-0" 17'-0"
Normal Vent
12,000 10'-0" 20'-6"
Emergency Vent 15,000 10'-0" 25'-6"
20,000 10'-0" 34'-0"
20,000 10'-6" 31'-0"
25,000 12'-0" 29'-8"
30,000 12'-0" 35'-6"
30,000 12'-6" 32'-9"
40,000 12'-0" 47'-6"
40,000 12'-6" 43'-8"
40,000 13'-0" 40'-4"
49,500 13'-0" 50'-0"
Internal
Ladder 57,500 14'-0" 50'-0"
Consult Highland Tank for NYC Tank Sizing Guide as
flanged and dished heads will add to height.
Optional Tank
Fittings Anchoring
as Required System
www.highlandtank.com • 29
Lube Tanks
Dependable Storage for Lube Oils
30 • www.highlandtank.com
Lube Tanks Sizing Guide
Single-Wall and Double-Wall
Emergency
Threaded Fittings Vent Fitting
Height
Tank Supports
Length Width
Volume Dimensions
Model Gallons Length Width Height
LT-120 120 2'-6" 2'-2" 3'-0"
LT-180 180 5'-0" 1'-10" 2'-8"
LT-280 280 5'-0" 2'-4" 3'-3"
LT-350 350 5'-0" 3'-6" 2'-8"
LT-500 500 5'-0" 2'-8" 5'-0"
LT-500-S 500 6'-0" 4'-2" 2'-8"
LT-750 750 7'-8" 2'-8" 5'-0"
LT-1000 1,000 10'-0" 2'-8" 5'-0"
LT-1000-S 1,000 6'-10" 4'-0" 5'-0"
LT-1500 1,500 15'-0" 2'-8" 5'-0"
LT-1500-S 1,500 8'-0" 5'-0" 5'-0"
LT-2000 2,000 17'-3" 2'-8" 5'-10"
LT-2000-S 2,000 8'-11" 5'-0" 5'-10"
LT-3000 3,000 13'-9" 5'-5" 5'-5"
LT-4000 4,000 18'-3" 5'-5" 5'-5"
LT-5000 5,000 22'-10" 5'-5" 5'-5"
LT-6000 6,000 13'-8" 10'-10" 5'-5"
LT-6000-S 6,000 27'-4" 5'-5" 5'-5"
LT-8000 8,000 18'-4" 10'-10" 5'-5"
LT-10000 10,000 22'-10" 10'-10" 5'-5"
LT-12000 12,000 27'-4" 10'-10" 5'-5"
LT-15000 15,000 34'-2" 10'-10" 5'-5"
LT-20000 20,000 46'-3" 10'-10" 5'-5"
Note: Add 2" (height of tank supports) to depth to determine overall height.
www.highlandtank.com • 31
Hopper Tanks
Hoppers are low profile, secondarily
contained, aboveground storage
tanks. They are suitable for the Fire Suppression 4" Spare 4"-6" Emergency
System Mounting Fitting Vent
storage of all types of motor fuels, Bracket
biofuels, new and used oils, waste
solvents and antifreeze. The Hopper
consists of an inner tank placed in
a second tub-like steel container,
12" x 18"
which provides a minimum of 110% Chamber
secondary containment. Hoppers with Hinged
Aluminum
are manufactured to UL-142® Lid – 2' fill
specifications; UL-2085 for Fire- with locking
cap & 1/2" 3-2" Fittings
Hoppers. A limited number of options, for suction,
such as pump mounts, pump and tank gauge
and vent.
accessories and finish paints
are available.
2" x 8" Vent Pipe
Standard Hopper Features with normal vent
UL-142® label;
2" Monitoring Tube
UL-2085 label for Fire-Hopper
Flat flanged heads
Capacities: 120-3,000 gallons
Primary Tank
Seam inspection and 5 psi factory air Seal Welded
test on primary tank To Roof
32 • www.highlandtank.com
Hopper Tanks Sizing and Specifications
Hopper Models Fire-Hopper Tanks
Fuel-Hopper – Designed for storing Volume
fuel oil or diesel for emergency Gallons Diameter Depth Diameter Height
generators
190 *48" 24" 60" 46"
Petro-Hopper – Suitable for storing 285 54" 29" 60" 46"
kerosene or gasoline/diesel for
500 72" 29" 78" 47"
vehicle fueling applications
1,000 120" 21" 126" 41"
Fire-Hopper – Specified in
applications where a fire-protected 1,500 138" 24" 144" 52"
tank is needed because of set- 2,000 138" 31" 144" 59"
back limitations and/or regulatory
2,500 138" 39" 144" 67"
insistence (This low profile, vertical
Fireguard® tank is available with the 3,000 138" 46" 144" 52"
STI standard 30-year *6" interstice on this size only, all others have a 3" interstice
limited warranty)
Haz-Hopper – Engineered for the
storage of waste oil or solvents Hopper Tanks
Volume
Gallons Diameter Depth Diameter Height
120 30" 40" 36" 46"
185 38" 40" 44" 47"
285 46" 40" 52" 51"
500 62" 40" 68" 53"
1,000 84" 42" 92" 54"
1,500 96" 48" 108" 60"
2,000 108" 51" 120" 63"
2,500 108" 62" 120" 75"
3,000 108" 76" 120" 91"
Hopper Tanks, equipped with optional pump and equipment packages, are an
economical way to save on your small fueling applications. With their lower
profile and smaller footprint, Hoppers cost less to install, are easier to fill and
operate, and they permit fuel to be dispensed from both sides of the tank.
www.highlandtank.com • 33
Bulk Storage Drums
Ideal for Emergency Fuel Storage for Heating and Emergency Generators
Typical Uses
Heating Oil Motor Fuel
Lubricants Waste Oils
34 • www.highlandtank.com
TOUGHTANKS
Durability, Performance and Affordability
Vertical Model
Height
T
330 72" 27.25" 44.25"
DW275 66" 27.25" 44.25"
DW330 80" 27.25" 44.25"
Length Width
Horizontal Model
Volume Dimensions
Gallons Length Width Height
137 30" 44.25" 27.25"
230 60" 44.25" 22.25" 1/2" Supply Fitting*
Height
Upright Model
Threaded Fittings
Volume Dimensions
Gallons Length Width Height
275 44.25" 27.25" 60"
Height
www.highlandtank.com • 35
All Highland Tank LPG
Vessels are made in America.
36
LPG Vessels
Custom Quality in Every Detail
Highland Tank is the leader in the steel Large LPG Vessels provide fuel for a
tank industry and has been building wide range of industrial, commercial
ASME pressure vessels for decades. and agricultural equipment including:
Years of experience enable Highland
Tank to provide solutions to the most Commercial and residential
challenging tank needs. A team of heating fuel
professionals in design, engineering, Fleet vehicle fueling by school
fabrication and service bring many districts, government agencies and
features and tactics from other steel public transit companies
tank fields to the LPG market. These
innovative techniques improve overall Agricultural: crop drying, vehicle fuel
quality and life of the vessel while and weed control
simplifying tank installation and Redundant fuel source for hospitals
everyday use. The flexibillity to build and other institutional, commercial
custom vessels sets HIghland Tank and industrial properties
apart from the competition.
Standby electric generators
Distribution for consumers
Autogas
www.highlandtank.com • 37
LPG Vessels
Standard Vessel Features
Volume: 3,900-60,000 USWG
ASME “U” Stamp
2:1 Elliptical heads – utilizes less space
on property
National Board Registration
Test Pressure 325 psi (250 psi WP
at 125º F
RT3 X-Ray Inspection
Flanged manway
SA516-70 high strength carbon steel
Grounding connectors
Grit blasted/coated with white urethane
topcoat (aboveground)
Grit blasted/coated with 75 mils of
HighGuard coating (underground)
External connections and outlets (valves
or fittings not included)
Lift Lugs
Cofferdam work chamber for easy access
(underground)
38 • www.highlandtank.com
LPG Vessels Sizing Guide
Volume USWG Diameter Straight Shell Length Overall Length
3,900 7'-0" 12'-4" 15'-2"
6,565 7'-0" 21'-17" 25'-5"
12,000 7'-0" 40'-6" 44'-4"
18,000 9'-1" 35'-6" 40'-5"
30,000 9'-1" 60'-3" 65'-2"
30,000 11'-0" 40'-4" 46'-2"
50,000 11'-0" 68'-5" 74'-3"
60,000 11'-0" 80'-6" 88'-10"
Standard openings are shown. Additional openings are available. Aboveground vessels available.
Overall Length
www.highlandtank.com • 39
40
Underground Tanks
Engineered Solutions for Safe Underground Storage
www.highlandtank.com • 41
HighGuard
Double-Wall Tank
Superior Tanks for a Tough Environment
is available
HighGuard is superior in strength UL-Listed Steel
UL-Listed
Steel Primary Tank
and rugged in appearance. After Flexible Designs Primary Tank 10
10 Ga. to 3/8" thick
gauge to .375"
manufacturing and rigorous testing, Volumes from 240-50,000 gallons thick
the tank’s exterior surfaces are Custom sizes
commercially blasted with steel grit in Multi-product storage
preparation for coating. compartments
42 • www.highlandtank.com
43
TITAN
®
44 • www.highlandtank.com
45
HotShot
Heated Residual Fuel Oil Storage Tank
Multi-Layered Engineering for Optimum Performance and Safety
46 • www.highlandtank.com
47
STI Technologies
®
48 • www.highlandtank.com
ACT-100-U® polyurethane coating ACT-100-U® Features
technology meets or surpasses all UL-58 and UL-1746 compliant
current UL standards. The
Must pass a 15,000 volt
ACT-100-U® is as rugged as the
spark test before shipment
STI-P3® tank but does not require
cathodic protection with anodes or No cathodic protection
monitoring. Performance tests prove monitoring required
that the 70 mil thick ACT-100-U® Available in single or
coating is far superior to Fiberglass double-wall
Reinforced Polyester (FRP) coatings
STI® standard 10-year
and much more resistant to
limited warranty
incidental damage.
30-year limited warranty
is available
www.highlandtank.com • 49
Multi-Compartment Option
Compartment Tanks are designed to Features:
store multiple grades of product, or Available with single or
different types of products, in the same double bulkheads
tank. This safe, economical alternative
Ideal for storing multiple grades
allows you to create multiple fuel
of gasoline
storage compartments without having
to install separate tanks for Diesel and biodiesel blend can be
each product. stored in the same tank
Double Bulkhead
Monitoring Panel
for Tank Gauging & Leak
Multi-Product Detection System
Dispenser Fill with Drop
Tube Valve
Automatic Tank Vent
Tank Gauge
Piping Sump Gauging Port
Submersible Pump
Polyester
Hold-Down
Strap
Leak
Detection
Sensor
50 • www.highlandtank.com
NYC Underground Steel Storage Tanks
NYC Heating Oil Tanks meet the city’s
Building Code Regulations and are
used for storage of commercial grade
heating oils. NYC Motor Fuel Storage
Tanks meet the city’s fire department
regulations and are installed when
safe storage of gasoline and diesel
motor fuels, including the ethanol and
Flanged and Dished Head Flat Flanged Head
biodiesel blends, is required. The New
York City Fire Department limits motor
fuel storage to a maximum of 12,000
gallons per tank. NYC storage tanks
are approved and labeled for service in
New York City.
www.highlandtank.com • 51
Selecting and Specifying Underground Tanks
Double-Wall Intersitial E D
Monitoring Pipe
HighGuard, Lifting Lugs
ACT-100-U ,
®
N
Standard on
STI-P3
®
P L H K Q M C all Tanks
Protected Steel
Outer Wall
TITAN HMW
®
O
R J
A B
52 • www.highlandtank.com
HighGuard, TITAN , ACT-100-U , STI-P3 , and HotShot Sizing Guide
® ® ®
www.highlandtank.com • 53
1 2 3
4 5 6
7 8 9
10 11 12
54 • www.highlandtank.com
Accessories
Customized To Meet Your Specific Needs
Highland Tank’s accessory line is designed to augment our wide selection of Petroleum and Chemical Liquid Storage Tanks,
making it easy to quickly and efficiently turn any of our tanks into a complete operating system. Take the guesswork out of your
installation with the use of one of our comprehensive master installation kits.
www.highlandtank.com • 55
Deadmen Anchoring System
Highland Tank’s Deadmen Anchoring
Systems are designed to secure
tanks or vessels at installations.
Polyester hold-down straps and
concrete beams are used to anchor
the tank or vessel and counteract its
natural buoyant forces.
Standard Features
No strap liners are required because
there are no metallic components
in the strap system that can make Polyester Hold-Down Straps
contact with the tank Installation Detail
Available without the cable, clamps Polyester Hold
and turnbuckles, for use with Down Strap
Concrete Deadmen Anchors
Available for tank diameters
3'-2" to 12'-0"
Turnbuckle with
Hook Ends Galvanized
Wire Rope
Cable
Clamps
Deadmen
Anchors Tie Down
Irons
56 • www.highlandtank.com
Deadmen Anchors are beams of Tank Volume Tank Dimensions Required Required
reinforced concrete placed alongside Gallons Diameter Length Deadmen Straps
the tank in the bottom of the 500 4'-0" 5'-5" 2 2
excavation. The weight of the backfill
1,000 4'-0" 10'-9" 2 2
on the Deadmen Anchors provides
additional resistance to buoyancy 1,000 5'-4" 6'-0" 2 2
forces acting on the tank. Properly 1,500 5'-4" 9'-0" 2 2
installed Deadmen Anchors, when 2,000 5'-4" 12'-0" 2 2
used exclusively with Polyester
2,500 5'-4" 15'-0" 2 2
Hold-Down Straps and the supplied
hardware, prevent tank flotation and 3,000 5'-4" 18'-0" 2 2
cost less than a concrete bottom 4,000 5'-4" 24'-0" 2 2
hold-down pad. Best of all, there is no
4,000 6'-0" 19'-0" 4 4
delivery charge for Concrete Deadmen
4,000 8'-0" 10'-8" 2 2
Anchors when they are shipped on
the same truck along with a Highland 5,000 6'-0" 23'-10" 4 4
storage tank. 5,000 8'-0" 13'-4" 2 2
6,000 6'-0" 28'-8" 6 6
Standard Features
6,000 8'-0" 16'-0" 2 2
Designed to work with standard
underground storage tanks from 500 8,000 8'-0" 21'-4" 4 4
to 50,000 gallons *8,000 10'-0" 14'-0" 2 2
Utilize a 4,000 psi concrete mix 10,000 8'-0" 26'-8" 6 6
reinforced with #4 rebar *10,000 10'-0" 17'-0" 4 4
Dimensions: 12,000 8'-0" 32'-0" 6 6
CDA-15: 120" L, 18" W, 12" H
*12,000 10'-0" 20'-6" 4 4
CDA-45: 120" L, 36" W, 18" H
15,000 8'-0" 40'-0" 8 8
Volume:
*15,000 10'-0" 25'-6" 4 4
CDA-15: 15 cubic feet (approx.)
CDA-45: 30 cubic feet (approx.) *20,000 10'-0" 34'-0" 6 6
www.highlandtank.com • 57
Steel Hold-Down Straps
This guide provides information about
Steel hold-down straps manufactured
specifically by Highland Tank. The A. Hold-down Strap
(with neoprene liner)
guide references dimensions of
Strap
standard underground tanks. Also
referenced are hold-down strap
Turnbuckle
specifications, recommended quantity,
spacing and anchor bolt requirements.
Contractor-supplied anchor bolt sizes
Turnbuckle
must be in accordance with this guide Diameter
for proper fit and system performance.
58 • www.highlandtank.com
Steel Hold-Down Straps Sizing Guide
Hold-Down Strap Anchor Bolt
Tank Volume Tank Dimensions Required Size Centerline Size
Gallons Diameter Length Quantity WxT Spacing Diameter
240 3'-2" 4'-0" 2 2" x .25" 2'-0" .75"
300 3'-2" 5'-0" 2 2" x .25" 2'-6" .75"
500 4'-0" 5'-5" 2 3" x .25" 2'-9" .75"
1,000 4'-0" 10'-9" 2 3" x .25" 5'-4" .75"
1,000 5'-4" 6'-0" 2 3" x .25" 3'-0" .75"
1,500 5'-4" 9'-0" 2 3" x .25" 4'-6" .75"
2,000 5'-4" 12'-0" 2 3" x .25" 6'-0" .75"
2,500 5'-4" 15'-0" 2 3" x .25" 7'-6" .75"
3,000 5'-4" 18'-0" 2 3" x .25" 9'-0" .75"
4,000 5'-4" 24'-0" 2 3" x .25" 12'-0" .75"
4,000 6'-0" 19'-0" 2 3" x .375" 9'-6" 1"
4,000 8'-0" 10'-8" 2 3" x .375" 5'-3" 1"
5,000 6'-0" 23'-10" 2 3" x .375" 11'-11" 1"
5,000 8'-0" 13'-4" 2 3" x .375" 6'-8" 1"
6,000 6'-0" 28'-8" 2 3" x .375" 14'-4" 1"
6,000 8'-0" 16'-0" 2 3" x .375" 9'-0" 1"
8,000 8'-0" 21'-4" 3 3" x .375" 7'-2" 1"
8,000 10'-0" 14'-0" 2 4" x .5" 7'-0" 1.25"
10,000 8'-0" 26'-8" 4 3" x .375" 6'-8" 1"
10,000 10'-0" 17'-0" 2 4" x .5" 8'-6" 1.25"
12,000 8'-0" 32'-0" 4 3" x .375" 8'-0" 1"
12,000 10'-0" 20'-6" 3 4" x .5" 6'-10" 1.25"
15,000 8'-0" 40'-0" 5 3" x .375" 8'-0" 1"
15,000 10'-0" 25'-6" 3 4" x .5" 8'-6" 1.25"
20,000 10'-0" 34'-0" 4 4" x .5" 8'-6" 1.25"
20,000 10'-6" 31'-0" 4 4" x .5" 7'-9" 1.25"
25,000 10'-6" 38'-9" 5 4" x .5" 7'-9" 1.25"
30,000 10'-6" 46'-6" 6 4" x .5" 7'-9" 1.25"
40,000 12'-0" 47'-6" 8 4" x .5" 6'-8" 1.25"
50,000 12'-0" 59'-6" 10 4" x .5" 6'-8" 1.25"
60,000 13'-0" 60'-6" 12 4" x .5" 5'-8" 1.25"
Note:
This information is provided as a service to our customers to assist with budgetary estimates.
Underground storage tank anchorage systems should be designed by a licensed professional engineer for the particular geographic location, soil conditions
and installation requirements of the specific jobsite. Highland Tank assumes no liability for errors or omissions in this information or for any consequent dam-
ages incurred by use or misuse of this guide.
Additionally, supplemental methods of restraint, such as grade-level reinforced concrete pads, should be designed in accordance with PEI/RIP-100-05.
Refer to appropriate Highland Tank and Steel Tank Institute installation instructions for additional information.
Tanks with diameter of 10' or greater require safety straps.
www.highlandtank.com • 59
Tank Support Systems Light-Duty Skids
Tank Support Systems are designed to
support the tank, maintain stability and
keep it stationary. They elevate the tank
to minimize corrosion concerns and
allow for easy visual inspection of the
tank’s underside.
Skids
Used to provide portability for empty Heavy-Duty Skids
horizontal tanks
Stabilize and maintain a fixed
elevation if being moved by towing
High under-tank clearance for visual
inspection of tank’s underside
Does not require extensive
site preparation
Two style skids:
• Small skids for tanks up to 1,500
gallons with runners fabricated
from steel angle
• Large skids with runners made
from steel pipe
Supports Supports
Structural steel supports maintain the
tank’s position and elevation
Provide clearance for visual
inspection of tank’s underside
Standard supports provide 6" of
clearance and are available on
horizontal tanks up to 4,000 gallons,
5'4" diameter
60 • www.highlandtank.com
Tank Saddles
UL Saddles
UL Saddles are designed for a specific
diameter horizontal storage tank and
Tank Saddles allow for visual
fabricated to the latest UL-142® design inspection of the entire
standards. They can be welded directly
to the tank or shipped loose. storage tank in accordance
Saddle Features
to the requirements of
Heavy-duty UL-142® steel the EPA’s SPCC rule.
construction for long-term durability
Standard saddles provide 6" of
clearance and are available up to 12"
high (Saddles higher than 12" must
be protected with a fire resistant
material with a two-hour fire rating)
Only two properly positioned saddles
per tank required
Four 1-1/8" diameter bolt holes are
provided to secure the saddles to the
concrete pad or piers
Saddles are painted to the same
specifications as the tank
61
Tank Saddle Sizing Guide
.625" Grounding
Hole
(1) Per Saddle
3"
3"
S
F F
L W
4'-0" 44" 8" 12" 2" 1. Do not rely on tack or seal-welded saddles
as a means for securing a tank in flood-prone
5'-4" 58" 8" 14" 2" areas. A hold-down system, connected to a
adequately sized anchor pad, is recommended.
6'-0" 65" 8" 17.5" 2"
2. A properly designed hold-down strap system
8'-0" 87" 10" 28.5" 2" with adequately sized reinforced concrete
hold-down pad is recommended to secure
9'-0" 98" 10" 34" 2" a tank in flood-prone areas.
10'-0" 108" 10" 39" 2"
10'-6" 114" 10" 42" 2"
12'-0" 130" 12" 50" 3"
12'-6" 114" 10" 42" 2"
13'-0" 130" 12" 50" 3"
62 • www.highlandtank.com
Nominal Capacity Tank Dimensions Saddle Spacing
Gallons Diameter Length (SS)
185 3'-2" 3'-4" 11"
240 3'-2" 4'-0" 1'-3"
300 3'-2" 5'-0" 1'-9"
500 4'-0" 5'-5" 1'-9"
1,000 4'-0" 10'-9" 4'-5"
1,000 5'-4" 6'-0" 1'-8"
1,500 5'-4" 9'-0" 3'-2"
2,000 5'-4" 12'-0" 4'-8"
3,000 5'-4" 18'-0" 7'-8"
4,000 5'-4" 24'-0" 10'-8"
4,000 6'-0" 19'-0" 8'-0"
4,000 8'-0" 10'-8" 3'-3"
5,000 6'-0" 23'-10" 10'-5"
5,000 8'-0" 13'-4" 4'-8"
6,000 6'-0" 28'-8" 12'-10"
6,000 8'-0" 16'-0" 6'-0"
8,000 8'-0" 21'-4" 8'-8"
8,000 10'-0" 14'-0" 4'-6"
10,000 8'-0" 26'-8" 11'-4"
10,000 10'-0" 17'-0" 6'-0"
12,000 8'-0" 32'-0" 14'-0"
12,000 10'-0" 20'-6" 7'-9"
15,000 8'-0" 40'-0" 18'-0"
15,000 10'-0" 25'-6" 10'-3"
20,000 10'-0" 34'-0" 14'-6"
20,000 10'-6" 31'-0" 12'-11"
25,000 10'-6" 38'-9" 16'-9"
30,000 10'-6" 46'-6" 20'-8"
40,000 12'-0" 47'-6" 20'-9"
50,000 12'-0" 59'-6" 26'-9"
50,000 12'-6" 54'-6" 24'-6"
60,000 12'-0" 71'-0" 33'-0"
60,000 12'-6" 65'-6" 30'-6"
60,000 13'-0" 60'-6" 27'-0"
70,000 13'-0" 72'-0" 32’-9”
63
Ladders, Platforms and Walkways Step-off Platform
Cage
Ladder
Step-off
Platform
Vertical Tank – External Ladder Vertical Tank – External Ladder Vertical Tank – External Ladder
Ladders Up to 20 ft. Ladders 20 to 30 ft. Ladders above 30 ft.
Open Ladder Uncaged 0 to 20 ft. / Caged 20 to 30 ft.
Note: OSHA-compliant internal ladders measure 16" wide and external ladders measure 24" wide.
64 • www.highlandtank.com
Stairways and Ships Ladders
Highland Tank fabricates standard Nominal Length
Model Tank Platform Height
and custom stairs to facilitate access S or SL Diameter Stairs Ships Ladders From Support Pad
to tank fill ports and manways.
30 4'-0" 29.6875" 17" 30"
OSHA standard design stairways
provide access to the top of the 47 5'-4" & 6'-0" 47.25" 26" 47"
tank from a platform attached to one 72 8'-0" 72.625" 41" 72"
end of the tank and include non- 88 10'-0" 88.8125" 50" 88"
skid fiberglass grating on the stair
108 12'-0" 108.625" 62" 108"
treads and platforms. Handrails and
provisions for anchoring stairway to
a support pad are also included. In
addition, we can manufacture Ships
Ladders for job sites with limited
space and can custom fabricate
ladders, platforms and walkways to
suit your site-specific needs.
24" 28"
Anchor
34"
Tank
Height
34" 9-11"
39-45°
60° 60°
Support Legs When Required
Top of Tank Access Perpendicular to Tank Head Top of Tank Access Parallel to Tank Head
www.highlandtank.com • 65
Manways and Manway Extensions
Manways are manufactured and
protected against corrosion using the
same methods and quality
control procedures as the storage
O.D.
tank. The welding and fabrication
specifications are in strict accordance
with Underwriters Laboratories, Inc.
I.D.
and OSHA. By manufacturing our own
manways, covers and extensions, we
Standard Lid Gasket
assure our customers of the same high Cork – .125"
quality as in our tanks. Neoprene – .125"
66 • www.highlandtank.com
Grade Level Manways
Grade Level Manways (GLM) are Round
designed to AASHTO H20 Nominal Manway Diameters
requirements. Round GLMs are Model Manway Skirt Manway Lid Manway Lid Skirt
available in sizes ranging from 12" to Number I.D. Inches Collar I.D. Inches O.D. Inches Thickness
48" diameter. Rectangular GLMs are
GLM-12 12" 14.5" 14" 10ga
available in lengths from 48" to 150"
and widths from 48" to 72". GLM-18 18" 20.5" 20" 7ga
GLM-24 24" 26.5" 26" 7ga
Each manway is constructed using A36 GLM-30 30" 32.5" 32" 7ga
steel plate from 10 gauge to .25" thick.
GLM-32 32" 34.5" 34" 7ga
Standard manways are fabricated with
a 12" skirt depth and fitted with 1.5" GLM-36 36" 38.5" 38" 7ga
x 2" x 3" steel concrete anchors seal GLM-42 42" 44.5" 44" .25"
welded to the manway skirt to ensure GLM-48 48" 50.5" 50" .25"
a secure installation. Standard manway
lids are constructed of .375” reinforced
checkered steel plate. Optional .375” Rectangular
checkered plate reinforced aluminum
Maximum
lids are available. Steel components Model Number of Doors Overall Length Skirt Thickness
receive a brush blast and are coated
R-GLM-48 1 48 .25"
with black enamel paint. Optional
polyurethane or epoxy coatings R-GLM-60 2 60 .25"
are available. R-GLM-90 3 90 .25"
R-GLM-120 4 120 .25"
Rectangular manways are custom-
R-GLM-150 5 150 .25"
fabricated to site-specific requirements.
Custom diameters and depths
are available upon request.
Manway Skirt
Concrete Anchors
1.5" x 2" x 3"
Manway Skirt
eter
Diam
.375" Checkered Plate
Length
Steel Lid
.50" x 1.5" 48"-72"
www.highlandtank.com • 67
Storage Tank Connections
Note:
Flanged fittings also available
in other configurations
**Half Coupling **Full Coupling
* Available in all standard steel A A
pipe sizes D
D
** Available as extras in
standard steel pipe sizes
E Bored to slip
from .125" to 6" nominal B E B over pipe
Please contact Highland Tank C C
for all other fitting requirements
150 Pound Screwed Flange Fitting Slip-on Welding Flange 150 Pound
A
D
G
68 • www.highlandtank.com
Standard Tank Head Design
Highland Storage Tank and ASME Pressure Vessel heads are of superior quality, value, and craftsmanship. Our heads are
fabricated of either A36 and SA516 Grade 70 carbon steel and 304, 304L, 316, or 316L stainless steel. Thicknesses range
from 14 gauge to 1-1/4".
Three styles of tank heads are available in diameters from 2'-0" to 14'-0":
Standard Flat-flanged Heads Standard Flanged & Dished Heads ASME Semi-elliptical Heads
These cost effective heads are When applications require slightly These superior heads are designed,
commonly used in applications higher operating pressures, our non- engineered, and manufactured
where the tank will be operated at ASME flanged & dished design gives to individual customers’ application
atmospheric pressure. The head’s the tank the most strength without and specifications for pressure
flange fits precisely inside the tank adding thickness. The lap-welded joint conditions. Tolerances comply with
shell to form a strong lap-welded joint. between the inner head flange and ASME requirements. These heads have
the outer tank shell provides superior a 2:1 diameter to depth ratio and are
“ribbed” strength. butt-welded to the tank shell.
Tank Head Capacity of Shell, Gal. Capacity of Head, Gal. Depth of Dish, Inches
Diameter per ft. per in. Standard Dished ASME Dished Standard Dished ASME Dished
2'-0" 23.5 1.96 8 8 4.4375" 4.4375"
2'-6" 36.7 3.06 14 14 5.1875" 5.1875"
3'-0" 52.9 4.4 22 24 6" 6.625"
3'-6" 72 6 33 35 6.8125" 7.4375"
4'-0" 94 7.8 46 50 7.625" 8.1875"
4'-6" 119 9.9 63 71 8.4375" 9.625"
5'-0" 147 12.3 82 93 9.25" 10.4375"
5'-6" 178 14.8 106 119 10" 11.1875"
6'-0" 211 17.6 133 157 10.8125" 12.625"
6'-6" 248 20.7 165 193 11.625" 13.4375"
7'-0" 288 24 201 244 12.4375" 14.8125"
7'-6" 330 27.5 242 293 13.25" 15.625"
8'-0" 376 31.3 288 347 14.0625" 16.4375"
8'-6" 424 35.4 340 422 14.8125" 17.8125"
9'-0" 476 39.7 398 490 15.625" 18.625"
9'-6" 530 44.2 461 566 16.4375" 19.4375"
10'-0" 587 49 531 669 17.25" 20.8125"
10'-6" 648 54 608 761 18.0625" 21.625"
11'-0" 711 59.2 692 862 18.875" 22.4375"
11'-6" 777 64.8 783 1023 19.6875" 24.4375"
12'-0" 846 70.5 882 1145 20.4375" 25.25"
www.highlandtank.com • 69
Our Commitment to You
Highland Tank is committed to building successful,
long-standing relationships with our customers. We
are dedicated to providing storage tanks of the highest
craftsmanship and performance. Within a business of
ever-changing technology, we are constantly striving to
exceed all your expectations.
70 • www.highlandtank.com
71
PETROLEUM & CHEMICAL