Sei sulla pagina 1di 38

DSC-P10/P12

Ver 1.0 2003. 03 SECTION 6 ADJ


Revision History ADJUSTMENTS

Link
Before starting adjustments SERVICE MODE
Adjusting items when replacing main parts and boards APPLICATION FOR ADJUSTMENT (SEUS)

DATA PROCESS
CAMERA SECTION ADJUSTMENTS
SERVICE MODE
PREPARATIONS BEFORE ADJUSTMENTS

INITIALIZATION OF 0E, 2F, 4F, 6F PAGE DATA

VIDEO SYSTEM ADJUSTMENTS

CAMERA SYSTEM ADJUSTMENTS

LCD SYSTEM ADJUSTMENTS

Contents of LEVEL 2 and LEVEL 3 Service Manual


CONTENTS LEVEL 2 LEVEL 3
1. SERVICE NOTE a ✕
2. DISASSEMBLY a ✕
3. BLOCK DIAGRAMS OVERALL ✕
POWER
4. PRINTED WIRING BOARDS AND CD-434, SW-386, ST-81 SY-83, JK-243, JK-244
SCHEMATIC DIAGRAMS MS-130 BOARD BOARD
5. REPAIR PARTS LIST EXPLODED VIEWS ✕
ELECTRICAL PARTS a
(JK-244, SY-83 BOARD)

2003C0500-1
©2003.3
9-876-227-51 Sony EMCS Co. Published by DI Customer Center
DSC-P10/P12

TABLE OF CONTENTS
Section Title Page Section Title Page
6. ADJUSTMENTS 8. Self Diagnosis Code ······················································ 6-34
Before Starting Adjustment ······················································· 6-1
1-1. Adjusting Items when Replacing * The color reproduction frame is shown on page 6-35.
Main Parts and Boards ···················································· 6-2
6-1. Camera Section Adjustments ··········································· 6-3
1-1. Preparations Before Adjustments ···································· 6-3
1-1-1. List of Service Tools ························································ 6-3
1-1-2. Preparations ····································································· 6-4
1-1-3. Discharging of the Flashlight Power Supply ··················· 6-5
1-1-4. Precautions ······································································ 6-6
1. Setting the Switch ···························································· 6-6
2. Order of Adjustments ······················································ 6-6
3. Subjects ··········································································· 6-6
4. Preparing the Flash Adjustment Box ······························· 6-7
1-2. Initialization of 0E, 2F, 4F, 6F Page Data ······················· 6-8
1-2-1. Initialization of 0E, 2F, 4F, 6F Page Data ······················· 6-8
1. Initializing 0E, 2F, 4F, 6F Page Data ······························· 6-8
2. 0E Page Table ·································································· 6-8
3. 2F Page Table ·································································· 6-8
4. 4F Page Table ·································································· 6-8
5. 6F Page Table ·································································· 6-9
1-3. Video System Adjustments ············································ 6-12
1. Composite Video Level Adjustment ······························ 6-12
1-4. Camera System Adjustments ········································· 6-13
Data Setting During Camera System Adjustments ········ 6-13
Picture Frame Setting ···················································· 6-14
1. Flange Back Adjustment
(Using the minipattern box) ·········································· 6-15
2. Flange Back Check ························································ 6-16
3. F No. Compensation ······················································ 6-16
4. Mechanical Shutter Adjustment ···································· 6-17
5. Light Value Adjustment ················································· 6-17
6. Mixed Color Cancel Adjustment ··································· 6-18
7. AWB 3200K Standard Data Input ································· 6-18
8. AWB 5800K Standard Data Input ································· 6-19
9. AWB 5800K Check ······················································· 6-19
10. AWB 3200K Check ······················································· 6-20
11. CCD Linearity Check ···················································· 6-20
12. Color Reproduction Adjustment ···································· 6-23
13. CCD White Defect Compensation ································ 6-24
14. CCD Black Defect Compensation ································· 6-24
15. Strobe Adjustment ························································· 6-25
16. AF Illumination Check ·················································· 6-26
1-5. LCD System Adjustments ············································· 6-27
1. LCD Initial Data Input ·················································· 6-27
2. VCO Adjustment (SW-386 Board) ································ 6-28
3. Bright Adjustment (SW-386 Board) ······························ 6-28
4. Contrast Adjustment (SW-386 Board) ·························· 6-29
5. Black Limit Adjustment (SW-386 Board) ····················· 6-29
6. V-COM Adjustment (SW-386 Board) ··························· 6-30
7. White Balance Adjustment (SW-386 Board) ················ 6-30
6-2. Service Mode ································································· 6-31
2-1. Application for Adjustment (SEUS) ······························ 6-31
2-1-1. Using Method of SEUS ················································· 6-31
1. Connection ····································································· 6-31
2. Operation ······································································· 6-31
2-1-2. Precaution on Use of SEUS ··········································· 6-31
2-2. Data Process ·································································· 6-32
2-3. Service Mode ································································· 6-32
1. Setting the Test Mode ···················································· 6-32
2. Bit Value Discrimination ··············································· 6-33
3. Mode Dial Check ··························································· 6-33
4. Switch Check (1) ··························································· 6-33
5. Switch Check (2) ··························································· 6-34
6. LED Check ···································································· 6-34
7. LCD & Back Light Bright Check ·································· 6-34

—2—
DSC-P10/P12
SECTION 6
COVER ADJUSTMENTS

Before starting adjustment

EVR Data Re-writing Procedure When Replacing Board


The data that is stored in the repair board, is not necessarily correct.
Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.

Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a
board is replaced.

(Machine before starting repair) PC PC (Machine after a board is replaced)

Save the EVR data Download the saved


to a personal computer. data to a machine.

Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM
to the replaced board.

Remove the EEPROM and install it.

(Former board) (New board)

Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or in-
stalled, save the data from the same model of the same destination, and download it.
(Machine to be repaired) PC (Machine to be repaired)

Download the data.

Save the data.

(The same model of the same destination)

After the EVR data is saved and downloaded, check the


respective items of the EVR data.
(Refer to page 6-2 for the items to be checked.)

6-1
DSC-P10/P12

COVER

1-1. Adjusting items when replacing main parts and boards


When replacing main parts and boards, adjust the items indicated by z in the following table.

Replaced parts
Block Mounted parts Board
replacement replacement replacement

(CAMERA DSP, 256M SDRAM)

(LCD drive, Timing generator)


(Camera Module)
(Back light unit)

(VIDEO AMP)
(CCD imager)
(LCD panel)

(EEPROM)
(EVR)
IC601 (HM (5M MI) board)
Adjustment section Adjustment

IC152 (CH-122 board)

(COMPLETE) (Note)
(COMPLETE)

(COMPLETE)
LCD901
(Note)

IC101

IC503

IC101
IC101

IC504
D901
Lens block assy

SW-386 board

SW-386 board
CD-434 board
SY-83 board
SY-83 board
SY-83 board
SY-83 board

SY-83 board

SY-83 board
ST-81 board
LCD block
LCD block
Flash unit

Initialization of 0E, 2F, 4F, Initialization of 0E, 2F, 4F, 6F page data z z
6F page data
Video Composite video level adj. z z z z z
Camera Flange back adj. z z z z
F No. compensation z z z z z
Mechanical shutter adj. z z z z z z
Light value adj. z z z z z
Mixed color cancel adj. z z z z z
AWB 3200K standard data input z z z z z
AWB 5800K standard data input z z z z z
CCD linearity check z z
Color reproduction adj. z z z z
CCD (white and black) defect
z z z z z
compensation
Strobe adj. z z z z z z
LCD LCD initial data input z z z
VCO adj. z z z z
Bright adj. z z z z
Contrast adj. z z z z
Black limit adj. z z z z
V-COM adj. z z z z z
White balance adj. z z z z z z

Table 6-1-1

Note : When replacing the lens block or the SY-83 board, refer to “Precaution on Replacing the Video Lens or the SY-83 board” of Flange
Back Adjustment. (See page 6-15)

6-2
DSC-P10/P12

COVER

6-1. CAMERA SECTION ADJUSTMENTS

1-1. PREPARATIONS BEFORE ADJUSTMENTS


1-1-1. List of Service Tools
• Oscilloscope • Color monitor • Vectorscope
• Regulated power supply • Digital voltmeter
• Calculating machine capable of calculating hexadecimal numbers.
Ref. No. Name Parts Code Usage
Auto white balance adjustment/check
J-1 Filter for color temperature correction (C14) J-6080-058-A
White balance adjustment/check
J-2 Pattern box PTB-450 J-6082-200-A
J-3 Color bar chart for pattern box J-6020-250-A
J-4 Siemens star chart J-6080-875-A For checking the flange back
J-5 Clear chart for pattern box J-6080-621-A
OS: Windows 98/98SE/Me/2000/XP Home/XP Pro
J-6 Personal computer
USB connector × 2
J-7 USB cable 1-823-932-11 For connecting the camera to PC
HASP key and application for adjustment Contact our service headquater of each area how to get
J-8
(SEUS) the application for adjustment (SEUS) and HASP key
J-9 Minipattern box J-6082-353-B For adjusting the flange back
J-10 Back ground paper J-2501-130-A For adjusting the strobe

J-1 J-2 J-3 J-4 J-5

J-6 J-7 J-8 J-9 J-10

and application for


adjustment (SEUS)

Fig. 6-1-1

6-3
DSC-P10/P12

1-1-2. Preparations
1) Connect the equipment for adjustments according to Fig. 6-1-3. Pattern box
2) Start up the application for adjustment (SEUS).

Note 1: Setting the “Forced CAMERA mode power ON Mode”


1) Select page: 00, address: 01, and set data: 01.
2) Select page: 2F, address: 21, and write data 03.
The above procedure will enable the camera power
L
to be turned on. After completing adjustments, be
sure to exit the “Forced CAMERA mode power ON
Mode”.

Note 2: Exiting the “Forced CAMERA mode power ON Mode”


1) Select page: 00, address: 01, and set data: 01. Front of the lens
2) Select page: 2F, address: 21, and write data: 00.
3) Select page: 00, address: 01, and set data: 00.
L = About 25 cm

Fig. 6-1-2

Insert the Memory Stick


DSC-P10/P12 and the Batteries*.

LOCK
To USB connector
AC power adaptor
To DC IN jack
AC IN

PC with USB connectors (x 2) To A/V OUT


(Windows 98/98SE/ME/2000/XP) jack
Vectorscope Color monitor
Terminated Video (yellow)
75 Ω

Audio (Black)

To USB connector
USB cable
(1-823-932-11)

HASP Key
To USB connector

Fig. 6-1-3

6-4
DSC-P10/P12

1-1-3. Discharging of the Flashlight Power Supply


R:1 kΩ/1 W
The capacitor which is used as power supply of flashlight is charged
(Part code:
with 200 V to 300 V voltage. Discharge this voltage before start- 1-215-869-11)
Capacitor
ing adjustments in order to protect service engineers from electric
shock during adjustment.

Discharge procedure
1. Press the FLASH button (SW-386 board S004 (CONTROL ST
-81
UP)) and set the NO FLASH mode.
2. Fabricate the discharging jig as shown in Fig. 6-1-5 locally by
yourself. Connect the discharging jig to the positive (+) and
negative (–) terminal of the flash voltage charge capacitor. Al-
low ten seconds to discharge the voltage.

Fig. 6-1-4

1 kΩ/1 W

Wrap insulating tape.

Fig. 6-1-5

6-5
DSC-P10/P12

1-1-4. Precautions
1. Setting the Switch
Unless otherwise specified, set the switches as follows and per-
form adjustments.
1. Mode Dial .......................................... CAMERA
2. ZOOM switch
(SW-386 board S001, S002) .............. WIDE end
3. EV (Menu display) ............................ 0EV
4. DISPLAY/LCD ON/OFF button
(SW-386 board S005) ........................ OSD OFF
5. WB (WHITE BALANCE)
(Menu display) ................................... AUTO
6. P.EFFECT (Menu display) ................ OFF
7. VIDEO OUT (SET UP setting) ......... NTSC

2. Order of Adjustments
Basically carry out adjustments in the order given.
Color bar chart (Standard picture frame)
Electronic beam scanning frame
H
Yellow

Magenta
White
Cyan
Green

C C=D D
Red
Blue

Magenta
Yellow

Green
White
Cyan

Blue
Red
CRT picture frame

B B V
A A=B/2 A Fig. b (monitor TV picture)
Enlargement
Fig. a
(VIDEO terminal of A/V jack
output waveform)
Difference in level
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig a
and the monitor TV display shown in Fig. b.

B
A

Fig. 6-1-6

3. Subjects
1) Color bar chart (Standard picture frame).
When performing adjustments using the color bar chart, ad-
just the picture frame as shown in Fig. 6-1-6. (Standard pic-
ture frame)
2) Clear chart (Standard picture frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations dur-
ing this time)

6-6
DSC-P10/P12

4. Preparing the Flash Adjustment Box


A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;

1) Provide woody board A, B and C of 15 mm thickness.

woody board A (2) woody board B (2) woody board C (1)

400 mm 370 mm 700 mm

513 mm 513 mm 700 mm

730 mm 700 mm

Fig. 6-1-7

2) Apply black mat paint to one side of woody board A and B.


3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B and C are internal. (Fig. 6-1-8)
woody board A

woody board B

woody board A

woody board B

woody board C

Fig. 6-1-8

6-7
DSC-P10/P12

COVER

1-2. INITIALIZATION OF 0E, 2F, 4F, 6F PAGE 2. 0E Page table


DATA Note 1: Fixed data-1: Initialized data.
(Refer to step 4 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
1-2-1. Initialization of 0E, 2F, 4F, 6F Page Data Data”)
1. Initializing 0E, 2F, 4F, 6F Page Data Note 2: Fixed data-2: Modified data.
Note 1: Initialize the data every page of 0E, 2F, 4F, and 6F. (Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Note 2: If the 4F page data has been initialized, the following Data”)
adjustments need to be performed again. Address Initial value Remark
1) Video system adjustment
2) LCD system adjustments 00 to FF Fixed data-1 (Initialized data)
Note 3: If the 6F page data has been initialized, the following
adjustments need to be performed again.
1) Camera system adjustments 3. 2F Page table
Note 1: Fixed data-1: Initialized data.
Adjusting Page 0E (Refer to step 5 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Adjusting Address 00 to FF Note 2: Fixed data-2: Modified data.
Adjusting Page 2F (Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Adjusting Address 00 to 7F Data”)
Adjusting Page 4F Address Initial value Remark
Adjusting Address 00 to FF 00 to 20 Fixed data-1 (Initialized data)
Adjusting Page 6F 21 00 Test mode
Adjusting Address 00 to FF 22 to 7F Fixed data-1 (Initialized data)

Initializing Method:
1) Click [Page Edit] on the SEUS screen to display the SEUS 4. 4F Page table
PAGE EDIT screen. Note 1: Fixed data-1: Initialized data.
2) Click [Page], and then enter the page to be initialized. (Refer to step 5 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
3) Click [Preset Data Read] to display the Set ID input screen. Data”)
4) For page 0E, enter Set ID = “00” and read the initializing data Note 2: Fixed data-2: Modified data.
on the SEUS PAGE EDIT screen. (Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
5) For page 2F, 4F and 6F, enter Set ID = “06” and read the ini- Data”)
tializing data on the SEUS PAGE EDIT screen. Address Initial value Remark
6) On the SEUS PAGE EDIT screen, change the data at “Fixed
00 to 81 Fixed data-1 (Initialized data)
data-2” address given in the table on the page to be initialized.
Note: New data for change are not listed in the table. If the 82 90 VCO adj. (NTSC mode)
data are to be changed, read and copy the data from the 83 9A VCO adj. (PAL mode)
same model. Copying the data from different models
84 91 V-COM adj.
may cause an operation failure.
7) Confirm that the data at respective adjustment addresses are 85 AF Bright adj.
the initial values (adjustment initial values) given in the table. 86 2D Black limit adj.
If different, change to the adjustment initial values.
87 Fixed data-1 (Initialized data)
8) Click [Write] to write the initializing data to the set.
9) Click [Close] to close the SEUS PAGE EDIT screen. 88 8C
White balance adj.
89 6C
Processing after Completing Initializing
8A 42 Contrast adj.
Order Page Address Data Procedure 8B to 9F Fixed data-1 (Initialized data)
1 2F 21 04 [Write] A0 80 Video sync level adj.
2 20 00 29 [set] A1 to A7 Fixed data-1 (Initialized data)
3 20 01 29 [Write] (Note) A8 Fixed data-2
A9 Fixed data-2
Note: At this time, the set is reset and the power is turns off once
and then on again. Accordingly, the message “Receive AA to FF Fixed data-1 (Initialized data)
Packet Error” is displayed on the SEUS screen, and the
SEUS goes in “disconnect” state, but this is not a trouble.
Click [Connect] on the SEUS screen to restore the “con-
nected” state.

6-8
DSC-P10/P12

5. 6F Page Table Address Initial value Remark


Note 1: Fixed data-1: Initialized data.
(Refer to step 5 of “ 1. Initializing of 0E, 2F, 4F, 6F Page 3A 00
Data”) 3B 00
Note 2: Fixed data-2: Modified data. 3C 00 Flange back adj.
(Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”) 3D 00
3E FF
Address Initial value Remark
3F Fixed data-1 (Initialized data)
00 to 0F Fixed data-1 (Initialized data)
40 00
10 FF
41 00
11 FF
42 00
12 FF
43 00
13 FF
AF Ilumination check. 44 00
14 00
45 00
15 90
46 00
16 FF
47 00
17 FF
48 00
18 34
49 00
19 F5 Flange back adj.
4A 00
1A 87
4B 00
1B 71
4C 00
1C 10
4D 00
1D 47
4E 00
1E 00
4F 00
1F 00
50 00
20 00
51 00
21 00
52 00
22 00
53 00
23 00
54 to 5F Fixed data-1 (Initialized data)
24 20
60 00
25 20
61 00
26 13
62 00 F No. compensation
27 46
63 00
28 0A
64 00
29 00 Flange back adj.
65 30
2A 00
66 FE Light value adj.
2B 00
67 6D
2C 00
68 to 6A Fixed data-1 (Initialized data)
2D 00
6B FF
2E 00 F No. compensation
6C 00
2F 00 Mechanical shutter adj.
6D 00
30 00
6E 00
31 00 Mixed color calcel adj.
6F 00
32 00
70 29
33 00
71 83
34 00
72 1F
35 00
73 DF AWB 3200K standard data input
36 00
74 29
37 00
75 0C
38 00
76 22
39 00

6-9
DSC-P10/P12

Address Initial value Remark Address Initial value Remark


77 6D A7 83
78 00 A8 D5
79 00 A9 FE
7A 00 AA 73
7B 00 AB 45 Color reproduction adj.
7C 00 AC 63
7D 00 AD 83
7E 00 AE 03
7F 00 AWB 3200K standard data input AF E9
80 00 B0 00 AWB 3200K standard data input
81 00 B1 00 AWB 5800K standard data input
82 00 B2 00 AWB 3200K standard data input
83 00 B3 00 AWB 5800K standard data input
84 00 B4 00 AWB 3200K standard data input
85 00 B5 Fixed data-1 (Initialized data)
86 00 B6 28
Strobe balance adj.
87 00 B7 6E
88 19 B8 10
89 66 B9 37
8A 30 BA 10
8B 6E BB 37
8C 19 BC 00
8D A7 BD 00
8E 32 BE 00
8F FB BF 00
90 00 C0 00
91 00 C1 00
92 00 C2 00
93 00 C3 00
94 00 C4 00
95 00 C5 00
AWB 5800K standard data input
96 00 C6 00
97 00 C7 28 Mechanical shutter adj.
98 00 C8 1B
99 00 C9 00
9A 00 CA 00
9B 00 CB 00
9C 00 CC 80
9D 00 CD 88
9E 00 CE 98
9F 00 CF 90
A0 2A D0 88
A1 80 D1 00
A2 5E D2 00
A3 C0 D3 00
A4 03 D4 00
A5 E9 Color reproduction adj. D5 00
A6 63 D6 00

6-10
DSC-P10/P12

Address Initial value Remark


D7 14 Mechanical shutter adj.
D8 FF
D9 FF
DA FF
DB 00
DC 00
DD 00
DE 00
DF 00
E0 00
E1 00
E2 00
E3 00
Strobe balance adj.
E4 00
E5 00
E6 00
E7 00
E8 00
E9 00
EA 00
EB 00
EC 00
ED 00
EE 00
EF 00
F0 to FF Fixed data-1 (Initialized data)

6-11
DSC-P10/P12

COVER

1-3. VIDEO SYSTEM ADJUSTMENTS


1. Composite Video Level Adjustment
Adjust the sync level of the composite video signal output and
check the burst level of the composite video signal output.
Mode PLAY
Signal Arbitrary
Measurement Point Video terminal of A/V OUT jack
(75 Ω terminated)
Measuring Instrument Oscilloscope
Adjustment Page 4F
Adjustment Address A0
Specified Value Sync level:
A = 286 ± 5 mV (NTSC mode)
A = 300 ± 5 mV (PAL mode)
Burst level:
B = 286 ± 30 mV (NTSC mode)
B = 300 ± 30 mV (PAL mode)
Note: Check that the data of page: 60, address: C1 is “01”.
If not, turn the power of unit OFF/ON.

Adjusting method:
Order Page Address Data Procedure
1 00 01 01 [Set]
2 4F 02 03 [Set]
3 40 F1 04 [Set]
Change the data and set
4 4F A0 the sync level (A) to the
specified value.
5 4F A0 [Write]
Check the burst level (B)
6
to the specified value.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 4F 02 00 [Set]
2 40 F1 00 [Set]
3 00 01 00 [Set]

B
A

Fig. 6-1-9

6-12
DSC-P10/P12

COVER

1-4. CAMERA SYSTEM ADJUSTMENTS After completing the camera system adjustments, release the
Before perform the camera system adjustments, check that the data setting:
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat- 1) Click [Page Edit] on the SEUS screen to display the SEUS
isfied. PAGE EDIT screen.
Note: For “CAMERA SYSTEM ADJUSTMENTS”, perform in 2) Click [Page], and then enter the page “0E”.
order of item numbers. 3) Click [Preset Data Read] to display the Set ID input screen.
4) Enter Set ID = “00” and read the initializing data on the SEUS
Data setting during camera system adjustments PAGE EDIT screen.
Perform the following data setting before the camera system ad- 5) Check that all the data is “FF”.
justments. 6) Click [Write] to write the initializing data to the set.
It is not necessary to perform the following data setting everytime 7) Click [Close] to close the SEUS PAGE EDIT screen.
when you perform some items of camera system adjustments con- 8) Release the data setting which has been executed before ad-
tinuously unless the power is turned off. Only when the power is justment.
turned off during this adjustments, perform the data setting again,
then continue the adjustments. Order Page Address Data Procedure
1 4F 01 00 [Write]
Set up setting:
2 7F 68 40 [Write]
1) VIDEO OUT of SET UP setting............... NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don't 3 60 2C 00 [Set]
set the SET UP setting to “PAL”) 4 60 6C 00 [Set]
5 4F 02 00 [Set]
Data setting method 6 2F 21 00 [Write]
7 4F 0F 00 [Write]
Order Page Address Data Procedure
8 00 01 00 [Set]
1 00 01 01 [Set]
2 6F 00 20 [Write]
3 4F 01 20 [Write]
4 7F 68 00 [Write]
5 20 00 29 [Set]
6 20 01 29 [Write] (Note 1)
7 00 01 01 [Set]
8 4F 0F 01 [Write]
9 2F 21 03 [Write]
Check the data changes
10 60 C1 [Read]
to “02”.
11 4F 02 02 [Set]
12 60 6C 01 [Set]
13 60 2C 01 [Set]
14 Wait for 1 second.
Note 1: At this time, the set is reset and the power is turned off
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click [Connect] on the SEUS screen to restore
the “connected” state. (In case that the power does not
turn on again, press the power button.)
Note 2: Repeat the “Data setting method”, if the power was turned
off and on during the “CAMERA SYSTEM ADJUST-
MENTS”.

6-13
DSC-P10/P12

Picture Frame Setting How to reset the zoom and focus when they deviated:
Mode CAMERA Order Page Address Data Procedure
Subject Color bar chart 1 60 90 00 [Set]
(Standard picture frame with the 2 60 91 00 [Set]
zoom lens at WIDE end)
3 60 92 YL [Set] (Note 2)
Measurement Point Video terminal of A/V OUT jack
(75 Ω terminated) 4 60 93 YH [Set] (Note 2)

Measuring Instrument Oscilloscope and monitor TV 5 60 01 79 [Write]

Specified value A=B/2, C/2=D, E=F Check the data changes


6 60 07 [Read]
to “01”.

Switch setting: 7 60 01 00 [Write]


1) FOCUS (Menu setting) ................. Multi AF Note 2: The data noted down at step 6 and 7 of “Setting method”.
2) MACRO (Control button) ............. ON
Check on the oscilloscope
Setting method:
1. Horizontal period
Order Page Address Data Procedure
A=B/2 C/2=D
Shoot the color bar chart
1 with the zoom WIDE B
C
end.
A D
2 60 8C 30 [Set]
Enter the output of
VIDEO OUT to the
3 monitor TV, and move
the position as shown in
Fig. 6-1-12.
Horizontal width of
black (A, D) on the color
4 bar chart should be a half
of that of one color bar
(B, C). (See Fig. 6-1-10)
With vertical width of
black (E, F) set in same,
the color bar chart
5
should come to the
center of monitor TV. Fig. 6-1-10
(See Fig. 6-1-11)
2. Vertical period
Check that the color bar
6 on the monitor TV is E E=F F
focused.
Read the data.
7 10 44 [Read] Note down the data, and
this is named YH data.
Read the data. V
8 10 45 [Read] Note down the data, and
this is named YL data. Fig. 6-1-11

Processing after Completing Adjustments: Check on the monitor TV

Order Page Address Data Procedure


1 60 8C 00 [Set]

Color bar chart picture frame Monitor TV picture frame

Fig. 6-1-12

6-14
DSC-P10/P12

1. Flange Back Adjustment Adjusting method:


(Using the minipattern box)
Order Page Address Data Procedure
The flange back of inner focus lens is adjusted automatically. If
shifted, the auto focus is disordered. Perform “Data setting
during camera sysem
Mode CAMER 1
adjustment”.
Subject Siemens star chart with ND filter (Refer to page 6-13)
for minipattern box (Note 1) 2 60 01 13 [Write]
Measurement Point Check operation on monitor TV 3 60 01 27 [Write] (Note 5)
Measuring Instrument Check the data changes
4 60 02 [Read]
Adjustment Page 6F to “01”.
Adjustment Address 18 to 3E, 40 to 53 Check that the data
Specified value 1 00 5 6F 3E [Read] satisfied the specified
value 1.
Specified value 2 0A to 40
Check that the data
Note 1: Dark Siemens star chart. 6 6F 24 [Read] satisfied the specified
Note 2: Check that the data of page: 60, address: 02 is “00”. If value 2.
not, press the RESET switch using a thin and long pin.
7 60 01 00 [Write]
Caution: 8 60 01 25 [Write]
If the video lens or SY-83 board was replaced, make a setting 9 Wait for 3 seconds.
by referring to “Precaution on Replacing the Video Lens or the
SY-83 Board” and then perform the adjustment. Note 5: The adjustment data will be automatically input to page:
6F, address: 18 to 3E and 40 to 53.
Preparations before adjustments:
1) The minipattern box is installed as shown in the following fig- Processing after Completing Adjustments:
ure. Order Page Address Data Procedure
Note 3: The attachment lenses are not used.
1 60 01 00 [Write]
Note 4: Take care not to hit the mini-pattern box when ex-
tending the lens. Perform “Flange Back
2
2) Install the minipattern box so that the distance between it and Check “.
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the [Precaution on Replacing the Video Lens or the SY-83
specified voltage ± 0.01 Vdc. Board]
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE The DSC-P10/P12 uses the position sensor to detect the zoom po-
end respectively. sition.
Accordingly, the zoom position will vary if the position data
Specified voltage: The specified voltage varies according to the changes due to the replacement of the video lens or the SY-83
minipattern box, so adjustment the power sup- board, thus causing the video lens to collide against the mecha-
ply output voltage to the specified voltage writ- nism end when the power is turned off.
ten on the sheet which is supplied with the mini- Though the position data is calibrated at the “Flange Back Adjust-
pattern box. ment”, add the following work when making an adjustment at the
Below 3 cm replacement of video lens to prevent a collision of video lens.

Minipattern box When Replacing the Video Lens


1) With current video lens assembled, turn the power on, and set
Camera the data of page: 6F, address: 3E to “FF”, then turn the power
off.
Camera 2) Replace the video lens with a new one, turn the power on, and
table perform the “Flange Back Adjustment”.
Regulated power supply
Thus, new position data will be written.
Output voltage : Specified voltage ± 0.01 Vdc
Output current : more than 3.5 A When Replacing the SY-83 Board
1) Replace the SY-83 board with a new one, set the mode dial to
“PLAY”, turn the power on, and set the data of page: 6F,
Red (+) address:3E to “FF”, then turn the power off.
2) Set the mode dial to “CAMERA”, turn the power on, and per-
Black (–) form the “Flange Back Adjustment”.
Yellow (SENS +) Thus, new position data will be written.

White (SENS –) Need not connected


Black (GND)
Fig. 6-1-13

6-15
DSC-P10/P12

2. Flange Back Check 3. F No. Compensation


Compensate the unevenness of the iris meter sensitivity.
Mode CAMERA
Subject Siemens star Mode CAMERA
(1.0 m from the front of the lens) Subject Clear chart
(Luminance: 200 to 400 lux) (Standard picture frame with the
Measurement Point Check operation on monitor TV zoom lens at WIDE end)
Measuring Instrument Measurement Point Data of page: 6F, address: 6B
Specified value Focused at the TELE end and Adjustment Page 6F
WIDE end Adjustment Address 60 to 64, 6B to 6D
Specified value 00
Checking method:
Note 1: Check that the data of page: 60, address: 02 is “00”. If
Order Page Address Data Procedure not, press the RESET switch using a thin and long pin.
“Flange Back Adjust-
1 Adjusting methd:
ment” is completed.
Place the Siemens star Order Page Address Data Procedure
2 1.0 from the front of the Perform “Data setting
lens. during camera system
1
To open the IRIS, adjustment”.
decrease the luminous (Refer to page 6-13)
intensity to the Siemens Perform “Picture frame
3
star up to a point before 2 setting”
noise appear on the (Refer to page 6-14)
image.
3 60 01 BB [Write] (Note 2)
4 60 8C 30 [Set]
Check the data changes
5 5F 3D 50 [Set] (Note 1) 4 60 02 [Read]
to “01”.
6 7B 98 94 [Set] Check that the data
Set the zoom lens to the 5 6F 6B [Read] satisfied the specified
TELE end then set the value.
7 center of the Siemens Note 2: The adjustment data will be automatically input to page:
star chart in the center of 6F, address: 60 to 64 and 6B to 6D.
the TV monitor.
Check that the lens is Processing after Completing Adjustments:
8
focused.
Order Page Address Data Procedure
9 60 2C 01 [Set]
1 60 01 00 [Write]
While observe the TV
Release “Data setting
monitor, change the
during camera system
10 zoom to the WIDE end 2
adjustment”
and check that the lens is
(Refer to page 6-13)
focused.
Note 1: How to find the data
Decrease the data of page: 5F, address: 3D until four sides
of a black frame can be seen on the monitor, then find
the value. The largest value under this condition will be
the seting value. If the value is less than 50, change
monitorrs.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 5F 3D [Read]
2 60 8C 00 [Set]
3 7B 98 [Read]
Release “Data setting
during camera system
4
adjustment”
(Refer to page 6-13)

6-16
DSC-P10/P12

4. Mechanical Shutter Adjustment 5. Light Value Adjustment


Adjust the period which the mechanical shutter is closed, and com- Adjust the standar light value.
pensate the exposure.
Mode CAMERA
Mode CAMERA Subject Clear chart
Subject Clear chart (Standard picture frame with the
(Standard picture frame with the zoom lens at WIDE end)
zoom lens at WIDE end) Measurement Point Data of page: 10, address: 0C and
Measurement Point Data of page: 6F, address: 6B 0D (2byte data) (Note 2)
Adjustment Page 6F Data of page: 6F, address: 65
Adjustment Address 6B to 6D, B8 to D7 Adjustment Page 6F
Specified value 00 Adjustment Address 65 to 67
Note 1: Check that the data of page: 60, address: 02 is “00”. If Specified value 1 0FE0 to 1020
not, press the RESET switch using a thin and long pin. Specified value 2 36 to 4E

Adjusting method: Note 1: Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Order Page Address Data Procedure Note 2: 2byte data is upper 1byte data and lower 1 byte data.
1 Perform “Data setting XX XX
during camera system Lower 1byte data (Page: 10, adderss: 0D)
adjustment”. Upper 1byte data (Page: 10, adderss: 0C)
(Refer to page 6-13)
Adjusting method:
Perform “Picture frame
2 setting” Order Page Address Data Procedure
(Refer to page 6-14) Perform “Data setting
3 60 01 AD [Write] (Note 2) during camera system
1
Check the data changes adjustment”.
4 60 02 [Read] (Refer to page 6-13)
to “01”.
Check that the data Perform “Picture frame
5 6F 6B [Read] satisfied the specified 2 setting”
value. (Refer to page 6-14)
Note 2: The adjustment data will be automatically input to page: 3 60 01 0D [Write] (Note 3)
6F, address: 6B to 6D and 8B to D7. Check the data changes
4 60 02 [Read]
to “01”.
Processing after Completing Adjustments: Read the data
5 10 0C [Read]
Order Page Address Data Procedure (Upper 1byte).
1 60 01 00 [Write] Read the data
6 10 0D [Read]
(Lower 1byte).
Release “Data setting
during camera system Check that the 2byte
2 7 data (Note 2) satisfied
adjustment”
(Refer to page 6-13) the specified value 1.
Check that the data
8 6F 65 [Read] satisfied the specified
value 2.
Note 3: The adjustment data will be automatically input to page:
6F, address: 65 to 67.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 60 01 00 [Write]
Release “Data setting
during camera system
2
adjustment”
(Refer to page 6-13)

6-17
DSC-P10/P12

6. Mixed Color Cancel Adjustment 7. AWB 3200K Standard Data Input


Correct the dispersion of Gr/Gb filter on CCD imager Adjust the white balance reference at 3200K.
Mode CAMERA Mode CAMERA
Subject Color bar chart Subject Clear chart
(Standard picture frame with the (Standard picture frame with the
zoom lens at WIDE end) zoom lens at WIDE end)
Adjustment Page 6F Adjustment Page 6F
Adjustment Address 6E and 6F Adjustment Address 70 to 87, B0, B2, and B4
Specified value 00 Specified value 00
Note 1: Check that the data of page: 60, address: 02 is “00”. If Note 1: Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin. not, press the RESET switch using a thin and long pin.

Adjusting method: Adjusting method:


Order Page Address Data Procedure Order Page Address Data Procedure
Perform “Data setting Perform “Data setting
during camera system during camera system
1 1
adjustment”. adjustment”.
(Refer to page 6-13) (Refer to page 6-13)
Perform “Picture frame Perform “Picture frame
2 setting” 2 setting”
(Refer to page 6-14) (Refer to page 6-14)
3 6F B5 FF [Write] 3 6F B5 FF [Write]
4 60 01 D7 [Write] 4 60 01 0B [Write] (Note 2)
5 Wait for 3 seconds. Check the data changes
5 60 02 [Read]
6 60 01 D5 [Write] (Note 2) to “01”.
Check the data changes Check that the data
7 60 02 [Read] 6 6F B5 [Read] satisfied the specified
to “01”.
value.
Check that the data
8 6F B5 [Read] satisfied the specified Note 2: The adjustment data will be automatically input to page:
value. 6F, address: 70 to 87, B0, B2 and B4.
Note 2: The adjustment data will be automatically input to page: Processing after Completing Adjustments:
6F, address: 6E and 6F
Order Page Address Data Procedure
Processing after Completing Adjustments: 1 60 01 00 [Write]
Order Page Address Data Procedure Release “Data setting
1 60 01 00 [Write] during camera system
2
adjustment”
Release “Data setting (Refer to page 6-13)
during camera system
2
adjustment”
(Refer to page 6-13)

6-18
DSC-P10/P12

8. AWB 5800K Standard Data Input 9. AWB 5800K Check


Adjust the white balance reference at 5800K.
Mode CAMERA
Mode CAMERA Subject Clear chart
Subject Clear chart (Standard picture frame with the
(Standard picture frame with the zoom lens at WIDE end)
zoom lens at WIDE end) Filter Filter C14 for color temperature
Filter Filter C14 for color temperature correction
correction Measurement Point Data of page: 6F, address: B5
Adjustment Page 6F Specified value 00
Adjustment Address 88 to A3, B1, and B3 Note: Check that the data of page: 60, address: 02 is “00”. If not,
Specified value 00 press the RESET switch using a thin and long pin.
Note 1: Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin. Checking method:
Note 2: Perform this check after “AWB 3200K Standard Data Order Page Address Data Procedure
Input” without a break.
Place the C14 filter on
1
the lens.
Adjusting method:
Perform “Data setting
Order Page Address Data Procedure during camera system
2
Place the C14 filter on adjustment”.
1
the lens. (Refer to page 6-13)
Perform “Data setting Perform “Picture frame
during camera system 3 setting”
2
adjustment”. (Refer to page 6-14)
(Refer to page 6-13) 4 6F B5 FF [Write]
Perform “Picture frame 5 60 01 3F [Write]
3 setting”
(Refer to page 6-14) Check the data changes
6 60 02 [Read]
to “01”.
4 6F A0 28 [Write]
Check that the data
5 6F A1 B0 [Write] 7 6F B5 [Read] satisfied the specified
6 6F A2 5E [Write] value.
7 6F A3 80 [Write]
8 6F B5 FF [Write] Processing after Completing Adjustments:
9 60 01 A5 [Write] (Note 3) Order Page Address Data Procedure
Check the data changes 1 60 01 00 [Write]
10 60 02 [Read]
to “01”. Release “Data setting
Check that the data during camera system
2
11 6F B5 [Read] satisfied the specified adjustment”
value. (Refer to page 6-13)
Note 3: The adjustment data will be automatically input to page:
6F, address: 88 to A3, B1 and B3.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 60 01 00 [Write]
Release “Data setting
during camera system
2
adjustment”
(Refer to page 6-13)

6-19
DSC-P10/P12

10. AWB 3200K Check 11. CCD Linearity Check


Check that CCD output keep being staraight even ISO sensitivity
Mode CAMERA
is changed.
Subject Clear chart
(Standard picture frame with the Mode CAMERA
zoom lens at WIDE end) Subject Clear chart
Measurement Point Data of page: 6F, address: B5 (Standard picture frame with the
zoom lens at WIDE end)
Specified value 00
Specified value 1 96 to 104 (Decimal)
Note: Check that the data of page: 60, address: 02 is “00”. If not,
press the RESET switch using a thin and long pin. Specified value 2 96 to 104 (Decimal)
Note: 2byte data is upper 1byte data and lower 1byte data.
Checking method: XX XX
Lower 1byte data
Order Page Address Data Procedure
(Page: 10, address: 81 or 83)
Perform “Data setting Upper 1byte data
during camera system (Page: 10, address: 80 or 82)
1
adjustment”.
(Refer to page 6-13) Checking method:
Perform “Picture frame Order Page Address Data Procedure
2 setting”
(Refer to page 6-14) Perform “Data setting
during camera system
3 6F B5 FF [Write] 1
adjustment”.
4 60 01 0F [Write] (Refer to page 6-13)
Check the data changes Perform “Picture frame
5 60 02 [Read]
to “01”. 2 setting”
Check that the data (Refer to page 6-14)
6 6F B5 [Read] satisfied the specified 3 75 09 04 [Set]
value. (Note 2) 4 60 1F 80 [Set]
5 77 F2 02 [Set]
Processing after Completing Adjustments:
6 60 12 9F [Set]
Order Page Address Data Procedure
7 60 14 90 [Set]
1 60 01 00 [Write]
8 60 05 16 [Set]
Release “Data setting
9 75 21 88 [Set]
during camera system
2 10 75 22 00 [Set]
adjustment”
(Refer to page 6-13) 11 75 23 BB [Set]
12 75 24 1B [Set]
13 75 25 24 [Set]
14 Wait for 2 seconds.
15 60 01 F9 [Write]
Check the data changes
16 60 E1 [Read]
to “08”.
Read the data
(Upper 1byte).
17 10 80 [Read]
Note down the data, and
this is named D02.
Read the data
(Lower 1byte).
18 10 81 [Read]
Note down the data, and
this is named D03.
This 2byte data (Note) is
19
named D1.
Write the data noted
20 6D 02 D02 [Write]
down at order No. 17.
Write the data noted
21 6D 03 D03 [Write]
down at order No. 18.
Write the data noted
22 6D 0A D02 [Write]
down at order No. 17.

6-20
DSC-P10/P12

Order Page Address Data Procedure Order Page Address Data Procedure
Write the data noted 48 60 E1 00 [Set]
23 6D 0B D03 [Write]
down at order No. 18. 49 77 72 09 [Set]
Read the data 50 Wait for 2 seconds.
(Upper 1byte).
24 10 82 [Read] 51 60 01 F9 [Write]
Note down the data, and
this is named D06. Check the data changes
52 60 E1 [Read]
Read the data to “08”.
(Lower 1byte). Read the data
25 10 83 [Read] (Upper 1byte).
Note down the data, and
53 10 80 [Read]
this is named D07. Note down the data, and
This 2byte data (Note) is this is named D08.
26
named D2. Read the data
(Lower 1byte).
27 6D 06 D06 [Write]
Write the data noted 54 10 81 [Read]
down at order No. 24. Note down the data, and
this is named D09.
Write the data noted
28 6D 07 D07 [Write] This 2byte data (Note) is
down at order No. 25. 55
named D5.
Write the data noted
29 6D 0E D06 [Write] Write the data noted
down at order No. 24. 56 6D 08 D08 [Write]
down at order No. 53.
Write the data noted
30 6D 0F D07 [Write] Write the data noted
down at order No. 25. 57 6D 09 D09 [Write]
down at order No. 54.
31 60 01 00 [Write]
Read the data
32 60 E1 00 [Set] (Upper 1byte).
58 10 82 [Read]
33 77 72 48 [Set] Note down the data, and
34 Wait for 2 seconds. this is named D0C.
35 60 01 F9 [Write] Read the data
(Lower 1byte).
Check the data changes 59 10 83 [Read]
36 60 E1 [Read] Note down the data, and
to “08”. this is named D0D.
Read the data This 2byte data (Note) is
(Upper 1byte). 60
37 10 80 [Read] named D6.
Note down the data, and
this is named D00. Write the data noted
61 6D 0C D0C [Write]
down at order No. 58.
Read the data
(Lower 1byte). Write the data noted
38 10 81 [Read] 62 6D 0D D0D [Write]
Note down the data, and down at order No. 59.
this is named D01. 63 60 E1 00 [Set]
This 2byte data (Note) is 64 60 01 00 [Write]
39
named D3. 65 60 12 00 [Set]
Write the data noted 66 60 14 00 [Set]
40 6D 00 D00 [Write]
down at order No. 37.
67 60 1F 00 [Set]
Write the data noted
41 6D 01 D01 [Write] 68 60 05 00 [Set]
down at order No. 38.
Read the data 69 75 21 [Read]
(Upper 1byte). 70 75 22 [Read]
42 10 82 [Read]
Note down the data, and 71 75 23 [Read]
this is named D04.
72 75 24 [Read]
Read the data
(Lower 1byte).
73 75 25 [Read]
43 10 83 [Read] 74 75 09 [Read]
Note down the data, and
this is named D05. 75 77 F7 [Read]
This 2byte data (Note) is 76 77 F2 [Read]
44
named D4.
77 77 72 [Read]
Write the data noted
45 6D 04 D04 [Write] Convert D3 to decimal
down at order No. 42. 78
notation, and obtain D3’.
Write the data noted
46 6D 05 D05 [Write] Convert D1 to decimal
down at order No. 43. 79
notation, and obtain D1’.
47 60 01 00 [Write]

6-21
DSC-P10/P12

Order Page Address Data Procedure Order Page Address Data Procedure
Calculate S1 using Write the upper 1 byte
following equations. 97 6D 14 S14 [Write] data obtained at order
80
(Decimal calculation) No. 96.
S1=(D3’÷D1’) × 100 Write the lower 1 byte
Check that the S1 98 6D 15 S15 [Write] data obtained at order
81 satisfies the specified No. 96.
value 1. Convert D6 to decimal
99
Convert S1 to hexadeci- notation, and obtain D6’.
mal notation. Convert D2 to decimal
The upper 1 byte data of 100
82 notation, and obtain D2’.
it is named S10.
The lower 1 byte data of Calculate S4 using
it is named S11. following equations.
101
(Decimal calculation)
Write the upper 1 byte S4=(D6’÷D2’) × 100
83 6D 10 S10 [Write] data obtained at order
No. 82. Check that the S4
102 satisfies the specified
Write the lower 1 byte value 2.
84 6D 11 S11 [Write] data obtained at order
No. 82. Convert S4 to hexadeci-
mal notation.
Convert D4 to decimal The upper 1 byte data of
85 103
notation, and obtain D4’. it is named S16.
Convert D2 to decimal The lower 1 byte data of
86
notation, and obtain D2’. it is named S17.
Calculate S2 using Write the upper 1 byte
following equations. 104 6D 16 S16 [Write] data obtained at order
87
(Decimal calculation) No. 103.
S2=(D4’÷D2’) × 100 Write the lower 1 byte
Check that the S2 105 6D 17 S17 [Write] data obtained at order
88 satisfies the specified No. 103.
value 1.
Convert S2 to hexadeci- Processing after Completing Adjustments:
mal notation.
Order Page Address Data Procedure
The upper 1 byte data of
89 Release “Data setting
it is named S12.
The lower 1 byte data of during camera system
1
it is named S13. adjustment”
(Refer to page 6-13)
Write the upper 1 byte
90 6D 12 S12 [Write] data obtained at order
No. 89.
Write the lower 1 byte
91 6D 13 S13 [Write] data obtained at order
No. 89.
Convert D5 to decimal
92
notation, and obtain D5’.
Convert D1 to decimal
93
notation, and obtain D1’.
Calculate S3 using
following equations.
94
(Decimal calculation)
S3=(D5’÷D1’) × 100
Check that the S3
95 satisfies the specified
value 2.
Convert S3 to hexadeci-
mal notation.
The upper 1 byte data of
96
it is named S14.
The lower 1 byte data of
it is named S15.

6-22
DSC-P10/P12

12. Color Reproduction Adjustment


Adjust the color separation matrix coefficient so that proper color
R-Y
reproduction is produced.
Mode CAMERA
Subject Color bar chart MG
(Standard picture frame with the R
zoom lens at WIDE end)
Measurement Point Video terminal of A/V OUT jack
(75 Ω terminated)
Data of page: 6F, address: B5 YE
W
Measuring Instrument Vectorscope B-Y
Adjustment Page 6F B
Adjustment Address A4 to AF
Specified value 00
Menu setting:
1) VIDEO OUT of SET UP menu
................................. NTSC (NTSC mode) G
CY
Note 1: Check that the data of page: 60, address: 02 is “00”. If Burst position
not, press the RESET switch using a thin and long pin.

Adjusting method:
Fig. 6-1-14
Order Page Address Data Procedure
Perform “Data setting
during camera system
1
adjustment”.
(Refer to page 6-13)
Perform “Picture frame
2 setting”
(Refer to page 6-14)
3 6F B5 FF [Write]
4 60 01 AB [Write]
5 Wait for 3 seconds.
6 60 01 A9 [Write] (Note 2)
Check the data changes
7 60 02 [Read]
to “01”.
Check that the data
8 6F B5 [Read] satisfied the specified
value.
Check the each color
luminance point is in
9
each color reproduction
frame.
Note 2: The adjustment data will be automatically input to page:
6F, address: A4 to AF.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 60 01 00 [Write]
Release “Data setting
during camera system
2
adjustment”
(Refer to page 6-13)

6-23
DSC-P10/P12

13. CCD White Defect Compensation 14. CCD Black Defect Compensation
Mode CAMERA Mode CAMERA
Subject Not required Subject Clear chart
Measurement Point Data of page: 60, address: 55 (Standard picture frame with the
zoom lens at WIDE end)
Note: Check that the data of page: 60, address: 02 is “00”. If not,
press the RESET switch using a thin and long pin. Measurement Point Data of page: 60, address: 55
Note 1: Check that the data of page: 60, address: 02 is “00”. If
Adjusting method: not, press the RESET switch using a thin and long pin.
Note 2: Check that there are no dust, no dirt and reflection of the
Order Page Address Data Procedure
clear chart.
Perform “Data setting Note 3: Any subject other than the clear chart should be in the
during camera system screen.
1
adjustment”.
(Refer to page 6-13) Adjusting method:
2 7D 64 1E [Set] Order Page Address Data Procedure
3 7D 69 0D [Set] Perform “Data setting
4 60 01 8B [Write] during camera system
1
Check the data changes adjustment”.
5 60 02 [Read] (Refer to page 6-13)
to “01”.
Check the data. 2 7D 65 4C [Set]
6 60 55 [Read] 00 to 7F: Normal 3 60 90 00 [Set]
80 to FF: Defective 4 60 91 03 [Set]
7 60 01 00 [Write] 5 60 92 00 [Set]
8 7D 64 0F [Set] 6 60 93 00 [Set]
9 7D 69 60 [Set] 7 60 01 79 [Write]
10 60 01 87 [Write] 8 60 30 08 [Set]
Check the data changes
11 60 02 [Read] 9 60 07 [Read]
Check the data changes
to “01”. to “01”.
Check the data. 10 60 01 8D [Write]
12 60 55 [Read] 00 : Normal
01 to FF: Defective Check the data changes
11 60 02 [Read]
to “01”.
Processing after Completing Adjustments: Check the data.
00: Proceed to “Process-
Order Page Address Data Procedure ing after Completing
12 60 55 [Read]
1 60 01 00 [Write] Adjustment”
00 to 14 : Normal
2 7D 64 [Read]
15 to FF : Defective
3 7D 69 [Read]
13 60 01 00 [Write]
Release “Data setting
14 7D 65 5A [Set]
during camera system
4 15 60 01 89 [Write]
adjustment”
(Refer to page 6-13) Check the data changes
16 60 02 [Read]
to “01”.
Check the data.
17 60 55 [Read] 00 : Normal
01 to FF : Defective

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 60 01 00 [Write]
2 60 30 00 [Set]
3 7D 65 [Read]
Release “Data setting
during camera system
4
adjustment”
(Refer to page 6-13)

6-24
DSC-P10/P12

15. Strobe Adjustment Adjusting method:


Adjust the light value and white balance when strobe light flashed.
Order Page Address Data Procedure
Mode CAMERA
Perform “Data setting
Subject Flash adjustment box (Note 2) during camera system
(50 cm from the front of lens) 1
adjustment”.
Measurement Point Data of page: 6F, address: DC (Refer to page 6-13)
and B5 2 60 2C 01 [Set]
Adjustment Page 6F 3 60 90 00 [Set]
Adjustment Address B6, B7 and D8 to EF 4 60 91 00 [Set]
Specified value 1 05 to 0B 5 60 92 FF [Set]
Specified value 2 00 6 60 93 FF [Set]
Note 1: Perform this adjustment in the Flash adjustment box. 7 60 6C 01 [Set]
Note 2: Refer to “4. Preparing the Flash adjustment box”. (See
8 60 01 79 [Write]
page 6-7).
Note 3: “Strobe Adjustment” is available only once after the Check the data changes
9 60 07 [Read]
power is turned on. If the adjustment is retried, press the to “01”.
RESET swich using a thin and long pin. 10 6F B5 FF [Write]
Note 4: Check that the data of page: 60, address: 02 is “00”. If
Check the flashing.
not, press the RESET switch using a thin and long pin. 11 60 01 B9 [Write]
(Note 5)
Switch setting: Check the data changes
12 60 02 [Read]
1) FLASH (Control button) .................... ON to “01”.
13 6F D8 [Read] Check the data is “00”.
14 60 01 00 [Write]
Check the data changes
15 60 ED [Read]
to “02”.
16 60 01 E7 [Write] Check the flashing.
Check the data changes
17 60 02 [Read]
to “01”.
18 6F D8 [Read] Check the data is “00”.
Check that the data
19 6F DC [Read] satisfied the specified
value 1.
Check that the data
20 6F B5 [Read] satisfied the specified
value 2.
Note 5: The adjustment data will be automatically input to page:
6F, address: B6, B7 and D8 to EF.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 60 01 00 [Write]
2 60 90 00 [Set]
3 60 91 00 [Set]
4 60 92 00 [Set]
5 60 93 00 [Set]
6 60 2C 00 [Set]
7 60 6C 00 [Set]
Release “Data setting
during camera system
8
adjustment”
(Refer to page 6-13)

6-25
DSC-P10/P12

16. AF Illumination Check


Check the deviation of optical axis of AF illuminator.
Mode CAMERA
Subject Flash adjustment box (Note 3)
(50 cm from the front of lens)
Measurement Point Displayed data of page: 6F,
address: 10
Adjustment Page 6F
Adjustment Address 10 to 17
Specified value 00
Note 1: Perform checking by making the shooting surface of the
Flash adjustment box perpendicular to the optical axis of
the camera.
Note 2: Perform this checking in the Flash adjustment box.
Restrict external light to enter the Flash adjustment box
as less as possible.
Note 3: Refer to “4. Preparing the Flash adjustment box”. (See
page 6-7).

Switch setting:
1) FOCUS (Menu setting) ....................... Multi AF

Adjusting method:
Order Page Address Data Procedure
Perform “Data setting
during camera system
1
adjustment”.
(Refer to page 6-13)
2 60 01 EF [Write] (Note 4)
Check the data changes
3 60 02 [Read]
to “01”.
4 6F 10 [Read] Check the data is “00”
Note 4: The adjustment data will be automatically input to page:
6F, adress: 10 to 17.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 60 01 00 [Write]
Release “Data setting
during camera system
2
adjustment”
(Refer to page 6-13)

6-26
DSC-P10/P12

COVER

1-5. LCD SYSTEM ADJUSTMENTS 1. LCD Initial Data Input


Before perform the camera system adjustments, check that the Mode PLAY
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied. Signal Arbitrary
Adjustment Page 4F
Note 1: Taken an extreme care not to destroy the liquid crystal Adjustment Address 80 to 8A, 8D, 92, 93, A3, A4
display module by static electricity when replacing it.
Note: “Memory Stick” must be insertde.
Note 2: Set the LCD BRIGHTENSS (SET UP setting) to the
NORMAL.
Input method:
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 4F, and write the data given in the following table.
Address Data Remark
80 4E
Fixed value
81 FF
82 90 VCO adjustment (NTSC mode)
83 9A VCO adjustment (PAL mode)
84 91 V-COM adjustment
85 AF Bright adjustment
86 2D Black Limit adjustment
87 41 Fixed value
88 8C
White Blance adjustment
89 6C
8A 42 Contrast adjustment
8D BE
92 2D
93 0E Fixed value
A3 24
A4 1C

Processing after Completing Input:


1) Select page: 00, address: 01, and set data: 00.

6-27
DSC-P10/P12

2. VCO Adjustment (SW-386 Board) 3. Bright Adjustment (SW-386 Board)


Set the VCO free-run frequency. If deviated, the LCD screen will Set the amplitude of the RGB decoder for driving the LCD to the
be blurred. specified value.
If deviated, the LCD screen image will be blackish or saturated
Mode PLAY
(whitish).
Signal Arbitrary
Mode PLAY
Measurement Point Data of page: 40, address: 4F
Signal Arbitrary
Adjustment Page 4F
Measurement Point Data of page: 40, address: 4F
Adjustment Address 82 (NTSC mode)
83 (PAL mode) Adjustment Page 4F
Specified value 00 Adjustment Address 85
Specified value 00
Menu setting:
1) VIDEO OUT of SET UP menu Adjusting method:
................................. NTSC (NTSC mode)
Order Page Address Data Procedure
(This adjustment must be performed in NTSC mode, so don’t set
the menu setting to “PAL”) 1 00 01 01 [Set]
2 4F 02 02 [Set]
Adjusting method:
3 4F 8F AF [Set]
Order Page Address Data Procedure 4 40 4F 02 [Set]
1 00 01 01 [Set] 5 40 4E 01 [Set]
2 4F 02 02 [Set] Check that the data
3 4F 99 1C [Set] 6 40 4F [Read] satisfied the specified
4 40 4F 01 [Set] value.

5 40 4E 01 [Set]
Processing after Completing Adjustments:
Check that the data
6 40 4F [Read] satisfied the specified Order Page Address Data Procedure
value. 1 4F 02 [Read]
7 4F 99 1D [Set] 2 00 01 00 [Set]
8 40 1D 82 [Set]
9 40 4F 01 [Set]
10 40 4E 01 [Set]
Check that the data
11 40 4F [Read] satisfied the specified
value.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 40 1D 80 [Set]
2 4F 02 [Read]
3 00 01 00 [Set]

6-28
DSC-P10/P12

4. Contrast Adjustment (SW-386 Board) 5. Black Limit Adjustment (SW-386 Board)


Set the level of the VIDEO signal for driving the LCD to the speci- Set the maximum amplitude of the RGB decoder for driving the
fied value. LCD to the specified value.
If deviated, the LCD screen image will be blackish or saturated If deviated, the LCD screen image will be blackish or saturated
(whitish). (whitish).
Mode PLAY Mode PLAY
Signal Arbitrary Signal Arbitrary
Measurement Point Data of page: 40, address: 4F Measurement Point Data of page: 40, address: 4F
Adjustment Page 4F Adjustment Page 4F
Adjustment Address 8A Adjustment Address 86
Specified value 00 Specified value 00
Note: Perform “Bright Adjustment” before this adjustment. Note: Perform “Bright Adjustment” before this adjustment.

Adjusting method: Adjusting method:


Order Page Address Data Procedure Order Page Address Data Procedure
1 00 01 01 [Set] 1 00 01 01 [Set]
2 4F 02 02 [Set] 2 4F 02 02 [Set]
3 4F 91 40 [Set] 3 4F 9F B5 [Set]
4 40 4F 03 [Set] 4 40 4F 04 [Set]
5 40 4E 01 [Set] 5 40 4E 01 [Set]
Check that the data Check that the data
6 40 4F [Read] satisfied the specified 6 40 4F [Read] satisfied the specified
value. value.

Processing after Completing Adjustments: Processing after Completing Adjustments


Order Page Address Data Procedure Order Page Address Data Procedure
1 4F 02 [Read] 1 4F 02 [Read]
2 00 01 00 [Set] 2 00 01 00 [Set]

6-29
DSC-P10/P12

6. V-COM Adjustment (SW-386 Board) 7. White Balance Adjustment (SW-386 Board)


Set the DC bias of the common electrode drive signal of LCD to Correct the white balance.
the specified value. If deviated, the LCD screen color cannot be reproduced.
If deviated, the LCD display will be move, producing flicker and
Mode PLAY
conspicuous vertical lines.
Signal Arbitrary
Mode PLAY
Measurement Point Check on the LCD screen
Signal Arbitrary
Measuring Instrument
Measurement Point Check on the LCD screen
Adjustment Page 4F
Measuring Instrument
Adjustment Address 88,89
Adjustment Page 4F
Specified value LCD screen must not be colored
Adjustment Address 84
Note 1: Check the white balance only when replacing the
Specified value The brightness difference between following parts. If necessary, adjust them.
the section-A and section-B is 1. LCD901 PANEL UNIT
minimum 2. IC101

Adjusting method: Adjusting method:


Order Page Address Data Procedure Order Page Address Data Procedure
1 00 01 01 [Set] 1 00 01 01 [Set]
2 4F 02 03 [Set] 2 4F 02 03 [Set]
3 40 F1 82 [Set] 3 40 F1 03 [Set]
Change the data so that Set the data.
4 4F 88 8C [Set]
4 4F 84 brightness of the section (Initial value)
A and section B is equal. Set the data.
5 4F 89 6C [Set]
Subtract 6 from the data, (Initial value)
5 4F 84 [Write]
and write this data. Check that the LCD
screen is not colored. If
Processing after Completing Adjustments: not colored, proceed to
6
“Processing after
Order Page Address Data Procedure
Completing Adjust-
1 40 F1 00 [Set] ments”.
2 4F 02 [Read] Change the data so that
3 00 01 00 [Set] 88 the LCD screen is not
7 4F [Write]
89 colored, and write this
data.

Processing after Completing Adjustments:


B A Order Page Address Data Procedure
1 40 F1 00 [Set]
A B 2 4F 02 [Read]
3 00 01 00 [Set]
B A

A B

Fig. 6-1-15

6-30
DSC-P10/P12

COVER

6-2. SERVICE MODE 2. Operation


• Page change
2-1. APPLICATION FOR ADJUSTMENT (SEUS) To change the page, click [Page] on the SEUS screen and enter
the page to be changed. The page is displayed in hexadecimal
The application for adjustment (SEUS) is used to change the coef- notation.
ficient for calculating the signal processing or EVR data. The SEUS
performs two-way communication between PC and set through • Address change
the USB terminal. The two-way communication result data can be To change the address, click [Address] on the SEUS screen and
written to the nonvolatile memory. enter the address to be changed. The address is displayed in
hexadecimal notation.
2-1-1. Using Method of SEUS
1. Connection • Data change
1) Connect the HASP key to the USB terminal of the PC. To change the data, click [Set] on the SEUS screen and enter
2) Connect the PC and set with the USB cable. the data. The data is displayed in hexadecimal notation.
3) Confirm that the set starts in the USB mode. This operation does not write the data to the nonvolatile memory.
4) Start the SEUS on the PC.
5) Click [Connect] on the SEUS screen. If the connection is nor- • Data writing
mal, the SEUS screen will be as shown in Fig. 6-2-1, indicat- To write the data to the nonvolatile memory, click [Write] on
ing the “connected” state. the SEUS screen and enter the data to be written.
Note: The SEUS will go in “disconnect" state, if the set is
• Data reading
turned off (for instance, by resetting the set). In such a
The data displayed on the SEUS screen are the data values at
case, click [Connect] on the SEUS screen to restore
the time when the pages and addresses were set, and they are
the “connected” state. not updated automatically. To check the data change, click
[Read] on the SEUS screen and update the displayed data.

2-1-2. Precaution on Use of SEUS


Wrong SEUS operation could clear correct adjustment data. To
prevent the data clear by mistake, it is recommended to save all
adjustment data by clicking [Page Edit] on the SEUS screen be-
fore starting the adjustment.

Fig. 6-2-1

6-31
DSC-P10/P12

COVER

2-2. DATA PROCESS 2-3. SERVICE MODE

In some adjustment items, the calculation of SEUS displayed data 1. Setting the Test Mode
(hexadecimal) is needed to check the specified data or to acquire
the adjustment data. In such a case, prepare a computer capable of Page 2F Address 21
calculating hexadecimal numbers.
Also, the data at two addresses are read, which are treated as 2 Data Function
bytes of upper 1 byte and lower 1 byte (4-digit hex. number), to
check the specified data. 00 Normal
01 Forced MOVIE mode

XX XX
02 Forced SCN mode
03 Forced CAMERA PROGRAM mode
04 Forced CAMERA mode
Displayed data at lower 1 byte address 08 Forced PLAY mode
Displayed data at upper 1 byte address 09 Forced SET UP mode

• Before setting the data, select page: 00, address: 01, and set
data: 01.
• In the case of page 2F, writing the data by clicking [Write] on
the SEUS screen causes the data to be written to the nonvolatile
memory. In this case, the Test mode is not released even if the
set is turned off, thus requiring extreme care.
• After the adjustment/repair finished, be sure to return the data
to “00” to restore the Normal mode. Also, select page: 00, ad-
dress: 01, and set data: 00.

6-32
DSC-P10/P12

2. Bit Value Discrimination 3. Mode Dial Check


In the following items, the bit values must be discriminated from
the data displayed on the SEUS. Whether bit values are “1” or “0” Page 20 Address 23
can be discriminated from the table shown below.

Data displayed on SEUS Data Function


01 SCN

00
02 CAMERA PROGRAM
03 CAMERA
07 PLAY
bit 3 to bit 0 discriminated 00 MOVIE
bit 7 to bit 4 discriminated 08 SET UP

Using method:
Bit values 1) Select page: 20, address: 23.
Display on the bit3 bit2 bit1 bit0 2) By discriminating the value of dispalyed data, the state of the
SEUS or or or or mode dial can be discriminated.
bit7 bit6 bit5 bit4
0 0 0 0 0
4. Switch Check (1)
1 0 0 0 1
2 0 0 1 0 Page 20 Address 80
3 0 0 1 1
4 0 1 0 0 Bit Function When bit value=1 When bit value=0
5 0 1 0 1 POWER SW
6 0 1 1 0 0 (CONTROL OFF ON
SWITCH BLOCK)
7 0 1 1 1
1
A 8 1 0 0 0
2
9 1 0 0 1
Shutter button
A 1 0 1 0 (XSHTR ON)
3 OFF ON
B 1 0 1 1 (CONTROL SWITCH
C 1 1 0 0 BLOCK)
D 1 1 0 1 Shutter button
(XAE LOCK ON)
B E 1 1 1 0 4 OFF ON
(CONTROL SWITCH
F 1 1 1 1 BLOCK)
MEMORY STICK
Example: If the displayed data is “8E”, bit 7 - bit 4 values can be IN SW
5 IN OUT
discriminated from block (A), and also bit 3 - bit 0 val- (MS-130 Board
ues from block (B). (MS Socket))

Using method:
1) Select page: 20, address: 80.
2) By discriminating the bit value of dispaly data, the state of the
switches can be discriminated.

6-33
DSC-P10/P12

5. Switch Check (2)

Page 20 Addresses 91, 92, 94

Using method:
1) Select page: 20, addresses: 91, 92 and 94.
2) By discriminating the dispaly data, the pressed key can be
discriminated.
Data
Address
00 to 0C 0D to 27 28 to 48 49 to 73 74 to A5 A6 to DC DD to FF
CONTROL DOWN CONTROL UP IMAGE SIZE/
91 MENU
(SELFTIMER) (STROBO) DELETE
(KEY AD0) (SW-386 board) No key input
(SW-386 board) (SW-386 board) (SW-386 board)
(IC402 tg) (S003)
(S008) (S004) (S010)
CONTROL RIGHT CONTROL LEFT DISPLAY/LCD
92 CONTROL SET
(MACRO) (REVIEW) ON/OFF
(KEY AD1) (SW-386 board) No key input
(SW-386 board) (SW-386 board) (SW-386 board)
(IC402 th) (S006)
(S007) (S005) (S009)
94 ZOOM (W) ZOOM (T)
(KEY AD3) (SW-386 board) (SW-386 board) No key input
(IC402 tk) (S001) (S002)

6. LED Check

Page 20 Address 04 Data 02

Using method:
1) Select page: 20, address: 04, set data: 02.
2) Check that all LED (STROB/CHG, POWER, SELF TIMER/
REC, AF ILLUMINATOR, AE/AF LOCK, MS ACCESS) are
lit.
3) Select page: 20, address: 04, set data: 00.

7. LCD & Back Light Bright Check

Page 40 Addresses DB and DC

Address Data Function


02 Check that LCD brightness is "Dark".
DB 12 Check that LCD brightness is "Normal".
22 Check that LCD brightness is "Bright".
00 Check that Back Light brightness is "Normal".
DC
08 Check that Back Light brightness is "Bright".

8. Self Diagnosis Code


Display Code Countermeasure Cause Caution Display During Error

C:32:ss Turn the power off and on again. Trouble with hardware. SYSTEM ERROR

Format the “Memory stick”. Unformatted memory stick is inserted. FORMAT ERROR
C:13:ss
Insert a new “Memory Stick”. Memory stick is broken. MEMORY STICK ERROR
When failed in the focus and zoom
E:61:ss Checking of lens drive circuit.
initialization.

Checking of flash unit or replacement Abnormality when flash is being
E:91:ss
of flash unit. charged.

6-34
DSC-P10/P12

FOR CAMERA COLOR REPRODUCTION ADJUSTMENT

Take a copy of CAMERA COLOR


REPRODUCTION FRAME with a
For NTSC mode
clear sheet for use.

R-Y

MG
R

YE
W
B-Y
B

G
CY

✄ DSC-P10/P12

6-35E
6-35
Reverse 987622751.pdf

Revision History

S.M. Rev.
Ver. Date History Contents
issued
1.0 2003.03 Official Release — —

Potrebbero piacerti anche