Sei sulla pagina 1di 2

CENTRAL MONITORING STATION

CENTRAL MONITORING STATION

HEYER Scalis Central Monitoring Station Software offers:

Limited wireless, unlimited wireless networking or


mixed network connection
Connection to 64 bedside monitors
Sound and light 3 alarm, adjustable alarm volume
Double screen, split-screen display patient medical
records and bedside care information
A variety of display format settings, optional waveforms,
different bed types and vital signs monitoring data
Inquiries about patient care information

SPECIFICATIONS

CENTRAL MONITORING SPECIFICATIONS HARDWARE REQUIREMENTS


Safety Safety
Based on MDD 93/42/EEC Council Directive 73/23/EEC
Council Directive 89/336/EEC
Language
English, Chinese Environment
o Temperature
Indicator Working 0 to 40 °C
o For general monitoring Transport and Storage -20 to 60 °C
Up to 16 display zones on screen with each displaying 2 waveforms and 1 parameter
o Humidity
group
Working <= 80 %
o For full disclosure monitoring Transport and Storage <= 90 %
1 display zone on screen with 12 waveforms and all parameter display in it
o Altitude
o For multi-lead ECG monitoring Working -500 to 4,600m
1 display zone on screen with 7 ECG waveforms and 3 parameters incl. HR, ST, PVC in it (-1,600 to 15,000 ft)
Transport and Storage -500 to 13,100m
Waveform
(-1,600 to 43,000ft)
ECG, RESP, PLETH, IBP, CO2, GAS
o Power Supply
Parameter Electrical specifications 100 - 240 V AC
HR, ST, RR, SPO2, PR, T1, T2, Td, ART, CVP, NS, NM, ND, CO 2, AwRR, INS, T.B., CO2Et, CO2Fi,
o Applicable range
O2Et, O2Fi, N2OEt, N2OFi, ISOEt, ISOFi, AgAwRR, MAC
Area other than point of care
Alarm
Display monitor
Parameters alarm, ST alarm, Arrhythmia alarm, Technical alarm, Audible and Visual Alarm
o 17’ (inch) color LCD
indicator for all alarms
o 1024 * 768 Resolution, 65535 color
Review
Interface
o 240 hours trend per bedside monitor, 1 minute resolution
o Intel Pentium or above, min. 256 MB host memory card, 1000 MB hard drive
o 6-minute short trend review of 4 parameters for each bedside monitor
o Power supply input socket
o 360 items parameters alarm per bedside monitor, 2 * 12 seconds waveform
o 2 serial ports
o 360 items arrhythmia alarm per bedside monitor, 2 * 12 seconds waveform
o 1 parallel port
o 72 hours full-disclosure waveform review
o 2 USB ports
o 10,000 patients history data review, including 48 hours trend and 100 items alarm data
o 1 RJ-45 Network interface
Network Protocol o 1 IBM Keyboard interface
o TCP/IP for layer 3, layer 4 of OSI o 1 PS/2 Mouse interface
o CMS protocol for layer 7 of OSI o 1 Sound output Interface
o 1 Mic input interface
Network capability
64 bedside patient monitors connectivity Printer
o Resolution 600 dpi
Patient Management o Speed 6 page / min.
Admit, Dismiss, Transfer, History monitoring information query o Paper size A4

HEYER Medical AG
Carl-Heyer-Str. 1-3 - D-56130 Bad Ems, Germany
Tel.: +49 2603 791 3 - Fax: +49 2603 70424 Subject to changes without notice.
info@heyermedical.de - www.heyermedical.de 06-2012 - EN