The document discusses whether an inspection described in UG-99(g) is required to be at a pressure not less than the actual test pressure divided by 1.3, if the test pressure is higher than the minimum required in UG-99(b). The reply confirms that yes, in this situation the inspection pressure must be at least the actual test pressure divided by 1.3.
The document discusses whether an inspection described in UG-99(g) is required to be at a pressure not less than the actual test pressure divided by 1.3, if the test pressure is higher than the minimum required in UG-99(b). The reply confirms that yes, in this situation the inspection pressure must be at least the actual test pressure divided by 1.3.
The document discusses whether an inspection described in UG-99(g) is required to be at a pressure not less than the actual test pressure divided by 1.3, if the test pressure is higher than the minimum required in UG-99(b). The reply confirms that yes, in this situation the inspection pressure must be at least the actual test pressure divided by 1.3.
test pressure that is higher than the minimum required in UG-99(b), is the
inspection described in UG-99(g) required to be at a pressure not less than
the actual test pressure divided by 1.3?
Reply: Yes.
Standard Designation: BPV Section VIII Div 1
Edition/Addenda: Latest (2013) Para./Fig./Table No: UG-45 vs UW-13(h) Subject Description: When can UW-13(h) over-ride UG-45 Date Issued: 01/12/2015 Record Number: 14-1797 Historical Interpretation numbers : Question(s) and Reply(ies): Question (1): With reference to Figure UW-13.4 is it permitted to have a nozzle neck thickness of t1 at any part of the nozzle neck that is away from the weld preparation for the attached piping [see U-1(e)(1)(a)]?
Reply (1): No.
Question (2): With reference to Figure UW-13.4 is it allowed to have trn at
any part of the neck beyond that defined by the tapered transitions shown in Fig. UW13.4?
Reply (2): No.
Standard Designation: BPV Section VIII Div 1
Edition/Addenda: 2013 edition Para./Fig./Table No: UG-34 and UG-44 Subject Description: Design Calculations for Blind Flanges Date Issued: 03/30/2015 Record Number: 14-1803 Historical Interpretation numbers : Question(s) and Reply(ies): Question (1). If a B16.5 or B16.47 blind flange is modified in a manner that is not covered by those standards, may pressure/temperature ratings of these standards be used in accordance with UG-44?
Reply (1). No.
Question (2). In the situation described in Question 1, would calculations
using the design provisions of UG-34 and UG-39 be required?