sites in BSC 2. ZEEI :BCF=(bcf no); � used to check status of particular BCF 3. ZEOL:(BCF NO); � used to check alarm of particular Site. 4. ZQSI ; � used to check status of X.25 link 5. ZNEL; � to check status of all TCSM. 6. ZEFS:(bcf no):L/U; � used to lock/unlock BCF. 7. ZEQS:BTS=(BTS no):L/U; � used to lock and unlock sector. 8. ZERS:BTS=(BTS no):TRX=(TRx no):L/U; Used to lock/unlock individual TRx 9. ZEFR:BCF NUM:OMU/SITE; OMU/SITE RESET 10. ZAHO:ET,(ET.no) ; � To check alarm on ET. 30,37 11. ZUSC:ET,E.no:BL/WO; � Used for making ET block and working. 12. ZDTF:TCSM,E.no ; � State checking of ET. 13. ZEEL; -To see no. of calls continuing in a BSC 14. ZAHO; -To see all BSC related alarm 15. ZEOL:(BCF no); -To see all alarm related to one BCF 16. ZEOH:::BCF=BCF num; To see alarm history of a site 17. ZEOL::NR=7706; -To see all sites having OMU blocked 18. ZEOL::NR=7704; -To see all sites having PCM blocked 19. ZEOL::NR=7705; -To see all sites having LAPD failure 20. ZEOL::NR=7411; -To see all sites on battery 21. ZQUS(Enter twice):BCF=(BCF no):TRE=1:2;7(Enter)1(Enter)200(Enter) � To know the receiving power of a PDH link :ODU: 22. ZEEL:BCF(Enter)Select Option; -To know the blocked BCF/BTS/TRx category 21. ZIGO; � To know the MML application done with BSC since the last two remote session 23. ZYEF:ET,(ET no); � Checking loop in ET 24. ZEOH:yy-mm-dd:hh-mm-ss:bcf=(bcf no); � Alarm related to particular date and time 25. ZYMO:ET,E.no ; � to check slips on ET 26. ZZZZ; � to terminate a remote session 27. ZDSB:::PCM=(ET no); � To find BCF no from a ET no/ Shows D channel details 28. ZDTI:::PCM=(ET num); -To find D channel details 29. ZEOH::NR=7767; -To see the alarm num history in BSC for the last 00.00.00 hours 30. ZEOL::NR=7767; -To find out the sectors down in one BSC 31. ZQSC(ENTER) QSC:0(ENTER) QSC:0,UNL;(ENTER) Command to change physical address ZQSC(ENTER) QSC:1(ENTER) QSC:1,UNL;(ENTER) 32. ZQLG(ENTER) QLG:0(ENTER) QLG:0;X2(ENTER) QLG:0:X25:UNL;(ENTER) Command to change linkage ZQLG(ENTER) QLG:1(ENTER) QLG:1;X2(ENTER) QLG:1:X25:UNL;(ENTER) Comment- If the X.25 link of BSC is locked from remote end the this command is used to unlock the X.25 link from local BSC end. Then both the command (28,29) should be executed 33. ZDSB:::PCM=(ET NO); To know wheather a ET is in use or not in use 34. ZWUP:ET NUM; � To know a ET type(TCSM/Abis) 35. ZQNI; -To know the numerical ID of a BSC 36. ZQRI:OMU; -To know the local IP allotted to BSC 37. ZAHP:::yyyy-mm-dd; -To know the alarm history of BSC 38. ZERO:BCF=(BCF NUM); -To know the TSC value for each trx 39. ZQWL:BCF=76; TO know the Q1 address of FIU s present in a site 40. ZEFO:BCF ID:IOP; To know the alarm configuration in a bts site 41. ZEFX:BCF NUM:INBR=alarm number:POL=OPEN/CLOSE; To change polarity of an external alarm 42. ZEFE: -External Alarm text modification command 43. ZDTC: D-channel name: BL/ WO; To change the state of D-channel 44. ZERC: Trx creation 45. ZERD: Trx Deletion (trx should be locked before deletion)