Sei sulla pagina 1di 2

13 Electrical

Components
and Systems

13.01 13.02 13.03 13.04 13.05 13.06 13.07 13.08

Substations & Power Electrical Cathodic Batteries And Electrical


Transformers Cables & Protection Lighting Equipment &
Switchgears Converters Accessories Power Supplies Bulk Materials
13.03.01G 13.05.01G 13.06.01G
Cathodic Electric Heat
Sub Stations Components Oil Filled Inverters Cables Accessories Protection Rechargeable Indoor Systems
Systems Batteries Tracing
13.01.01G 13.01.08G 13.02.01G 13.03.02G 13.04.01G 13.05.02G 13.07.01G 13.08.01G
13.06.02G
Overhead Oil filled HV Monitoring and For Industrial Electric Heat
HV Substations Rectifiers HV cables Cable Trays Remote Control Uninterruptible Plants and
Electrical Lines Transformers Power Supply Tracing Systems
and Ladders Systems Buildings
13.01.02G 13.01.09G 13.02.02G 13.04.02G 13.08.02G
13.03.03G 13.05.03G 13.06.03G 13.07.02G
Oil filled MV/LV 13.04.04G
MV/LV Impressed Energy Storage For EX Heat Trace
Substations Bus Ducts Transformers DC/DC MV cables
Non-Metal Current Anodes Systems Classified Areas Cables
13.02.03G 13.04.03G 13.05.04G
Circuit 13.04.05G 13.08.03G
Protection Dry Type Sacrificial Outdoor Bulk Materials
Transformers LV Cables for Pneumatic
Switchgears devices Metal Anodes Systems
Instrumentation
13.01.10G
13.02.04G 13.07.03G Assembly
13.04.06G For Industrial 13.08.04G
HV Large Power Plants and Power
HV Switchgears Transformers MCT Blocks Buildings Distribution
13.01.03G
13.01.11G
13.02.05G 13.07.04G Boards
13.08.05G
LV/MV Cable Glands, For EX Spare Parts for
Gas-insulated Autotransformer Classified Areas
Joints and Electrical
13.01.04G Power Factor 13.02.06G
Terminals Equipment
Improvement Special 13.04.07G
Capacitors and Road Lighting
Air-insulated Filters Application
Transformers Industrial Type
13.01.12G 13.07.05G
13.01.05G 13.02.07G
HV Grounding 13.04.08G Fixtures and
Hybrid Resistors For EX Accessories
13.01.13G Classified Areas
13.02.08G 13.07.06G
13.01.06G LV/MV Poles and
Power Reactors Floodlight
MV Switchgears Conduits Towers
13.01.14G 13.07.07G
13.01.07G Electrical 13.04.09G Signaling
Control Desks Equipment
LV Switchgears Industrial Type
13.01.15G
Junction/Marsh 13.04.10G
alling Boxes
For EX
13.01.16G Classified Areas
Spare Parts for
Substation
Maintenance

Rev. 06
June 2016
VISIT WWW.SUPPLHI.COM TO EXPLORE
VISIT WWW.SUPPLHI.COM THE
TO EXPLORE VENDORS
THE VENDORS ININ EACH
EACH CATEGORY
CATEGORY
SupplHi LTD©2016 —This content is property of SupplHi LTD
Electrical
Components
The set of electrical and mechanical equipment needed for the transmission and use of electrical energy. This can
be as simple as a light bulb connected to a battery or as complex as distribution systems that carry power from
generating centers to intermediary stations who then feed the power out to plants and housing.
and Systems

Main rationales behind the Standard Categorization

Substations & Switchgears Power Converters Batteries and Power Supplies


• A Substation is an indoor or outdoor location containing • The rationale was to separate converters based on type of • These are used in industrial applications where readily available
switchgears, transformers, bus ducts and protection equipment. application: energy is needed but might not always be available.
• Switchgears are the combination of electrical disconnect switches • DC/AC Converters (Also Called Inverters) • UPS differ from Emergency generators in that they can provide
and fuse/circuit breaker used to manage and isolate a power • AC/DC Converters (Also called Rectifiers) almost instantaneous protection from power interruptions since
supply system. they supply energy stored in batteries. This category includes both
• DC/DC Converters (Also called DC transformers)
• Circuit Protection devices include all the methods of equipment general purpose and specific application systems (e.g. Marine UPS,
protection and human safety. This category refers to fuses, circuit which need to be resilient to elevated levels of vibration).
breakers, disconnectors, surge and lightning arrestors and • Energy storage systems are a full integrated turnkey solution,
bonding/grounding/earthing systems. Electrical Cables & Accessories typically contained in a metal jacket.
• Whenever HV is separated from MV or LV it is because of the • Communication Cables can be found in the Instrumentation group
different requirements specific power stations may have (High as this group only concerns electrical components only.
Voltage is intended as greater than 33KV)
• Subsea solutions have been separated due to their nature and
• Switchboards are not included as a category since they can be specific skills required to install such systems. Lighting
considered a subset of Switchgears. Thus they would be listed
under LV Switchgears. • HV is intended as above 33KV, MV between 1KV and 33KV and LV
up to 1KV • The rationale is to divide systems based on the type of usage:
industrial (indoor and outdoor) and road.
• Cable Glands are also known as fittings since they are a device
designed to attach and secure the cable to the equipment. • The further distinction between EX classified areas and generic
industrial use was made due to the specific needs of the former
• EX classified areas refers to places with specific requirements due areas.
Transformers to potential hazards. Therefore, this equipment must be thoroughly
tested to ensure it does not trigger any dangerous events (e.g.
• The rationale was to separate transformers based on type of explosions).
insulation: Oil Filled (HV destined to primary distribution, LV • Industrial type refers to generic use for any industry. Electrical Equipment & Bulk Materials
destined to low voltage distribution) and Dry Type (air or resin).
• Large Transformers are mainly intended for HV power stations and • Electrical heat tracing systems are used to maintain or raise the
interconnecting systems. temperature of an object (usually a pipe or a vessel). Turnkey kits
• Grounding resistors protect power transformers and generators from
Cathodic Protection have to be distinguished from simple cables that wrap around the
object to heat.
damaging fault currents. • Cathodic protection refers to the technique used to reduce the • Spare parts include everything might be needed as a replacement in
• Power Reactors are not to be confused with transformers. While a corrosion of a metal surface. an electrical system (e.g. switches, plugs, etc.)
Power Transformer is designed for efficient power transfer from one • 13.05.01G is intended as a full supply. Basically a, complete ready
voltage system to another, a shunt reactor is intended only to • 13.08.03G includes any material used for construction and
to use protection system (including anodes, rectifier etc.) assembly of Pneumatic Instrumentation.
consume reactive VARs.
• Special Application: includes furnace transformers, traction
transformers and mobile transformers.

Rev. 06
June 2016
VISIT WWW.SUPPLHI.COM TO EXPLORE
VISIT WWW.SUPPLHI.COM THE
TO EXPLORE VENDORS
THE VENDORS ININ EACH
EACH CATEGORY
CATEGORY
SupplHi LTD©2016 —This content is property of SupplHi LTD

Potrebbero piacerti anche