Sei sulla pagina 1di 2

6/12/2019 CONTROL PANEL (SR-4 GENERATOR TERMINAL BOX MOUNTED) 5JG00001-UP(SEBP1842 - 01) - Documentation

Shutdown SIS

Previous Screen

Product: GEN SET ENGINE


Mode l: 3114 GEN SET ENGINE 5JG
C onfiguration: C O NTR O L PANEL (SR -4 GENER ATO R TER MINAL BO X
MO UNTED) 5JG00001-UP

Testing and Adjusting


3114, 3116 and 3126 Industrial, Marine and Generator Set Engines
Media Number -SENR9558-04 Publication Date -01/10/2008 Date Updated -29/10/2008

i04643912

Engine Crankcase Pressure (Blowby) - Test


SMCS - 1215; 1317

Table 1
Tools Needed

Part Number Part Name Quantity

348-5430 Multi-Tool Gp 1

285-0900 Blowby Tool Group 1

NETG5049 Software License 1

Damaged pistons or rings can cause too much pressure in the crankcase. This condition will cause the engine to run
rough. There will be more than a normal amount of blowby fumes rising from the crankcase breather. The breather can
then become restricted in a short time, causing oil leakage at gaskets and seals that would not normally have leakage.
Blowby can also be caused by worn valve guides or by a failed turbocharger seal.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sisweb/sisw… 1/2
6/12/2019 CONTROL PANEL (SR-4 GENERATOR TERMINAL BOX MOUNTED) 5JG00001-UP(SEBP1842 - 01) - Documentation

Illustration 1 g02709261
348-5430 Multi-Tool Gp

The 348-5430 Multi-Tool Gp , or the 285-0900 Blowby Tool Group is used to check the amount of blowby. Refer to
Tool Operating Manual, NEHS1087, " 348-5430 Multi-Tool Gp " for the test procedure for checking the blowby.

C opyright 1993 - 2019 C ate rpillar Inc. W e d Jun 12 2019 20:22:40 GMT+0400 (Gulf Standard Tim e )
All R ights R e se rve d.
Private Ne twork For SIS Lice nse e s.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/sisweb/sisw… 2/2