Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
: T60404-N4646-X653
V AC U UM SC H M ELZE
K-no.: 24509 6 A Current Sensor modul for 5V-Supply voltage Date: 08.04.2008
For electronic current measurement:
DC, AC, pulsed, mixed ..., with a galvanic
isolation between primary circuit
(high power) and secondary circuit
(electronic circuit)
Constructed and manufactored and tested in accordance with EN 61800-5-1 (Pin 1 - 6 to Pin 7 – 9)
Reinforced insulation, Insulation material group 1, Pollution degree 2
Sclear Clearance (component without solder pad) 7 mm
Screep Creepage (component without solder pad) 7 mm
Vsys System voltage overvoltage category 3 RMS 300 V
Vwork Working voltage (tabel 7 acc. to EN61800-5-1)
overvoltage category 2 RMS 650 V
UPD Rated discharge voltage peak value 1320 V
K-no.: 24509 6 A Current Sensor modul for 5V-Supply voltage Date: 08.04.2008
For electronic current measurement:
DC, AC, pulsed, mixed ..., with a galvanic
isolation between primary circuit
(high power) and secondary circuit
(electronic circuit)
1 3
22,2
Marking:
10
F DC 4646X653
24 F DC
0,5
Ø1,0 3,5±0,5
1,84
7,62
0,46x0,46
12 2,54
2x2,54
=5,08
DC = Date Code
F = Factory
Schematic diagram
IP 9 VC
1..3
V=4 7 Vout
RiM 8 GND
ref
4..6
. 3 1
1 6 ±20 2.5±0.625 1:2000 0.33 >
. 4 6
>
3 1
2 3 ±10 2.5±0.625 2:2000 1.5 >
4 6 >
. 3 1
3 2 ±6.7 2.5±0.625 3:2000 3 >
. 4 6 >
Applicable documents
Current direction: A positive output current appears at point IS, by primary current in direction of the arrow.
Housing and bobbin material UL-listed: Flammability class 94V-0.
Enclosures according to IEC529: IP50.
tr: Response time (describe the dynamic performance for the specified measurement range), measured as delay time
at IP = 0,9 . IPN between a rectangular current and the output voltage VOUt (Ip)
∆t (IPmax): Delay time (describe the dynamic performance for the rapid current pulse rate e.g short circuit current)
measured between IPmax and the output voltage Vout(IPmax) with a primary current rise of diP/dt ≥ 100 A/µs.
UPD Rated discharge voltage (recurring peak voltage separated by the insulation) proved with a sinusoidal voltage Ve
UPD = √2 * Ve / 1,5
Vvor Defined voltage is the RMS valve of a sinusoidal voltage with peak value of 1,875 * UPD required for partial discharge
test in IEC 61800-5-1
Vvor = 1,875 *UPD / √2
Vsys System voltage RMS value of rated voltage according to IEC 61800-5-1
Vwork Working voltage voltage according to IEC 61800-5-1 which occurs by design in a circuit or across insulation
V0: Offset voltage between Vout and the rated reference voltage of Vref = 2,5V.
Vo = Vout(0) - 2,5V
V0H: Zero variation of Vo after overloading with a DC of tenfold the rated value
V0t: Long term drift of Vo after 100 temperature cycles in the range -40 bis 85 °C.
Xges(IPN): Permissible measurement error including any drifts over the temperature range by the current measurement IPN
Vout (I PN ) − 2,5V Vout (I PN ) − Vref
X ges = 100 ⋅ −1 % or X ges = 100 ⋅ −1 %
0,625V 0,625V
Authorized Distributor
Vacuumschmelze:
T60404-N4646-X653