Sei sulla pagina 1di 136

INSTALLATION AND OPERATION MANUAL

METROFIBER
202.6012.53-3
2009 - DIGITEL S.A. INDÚSTRIA ELETRÔNICA
Rua Dr. João Inácio, 1165
Bairro: Navegantes
CEP 90230-181 • Porto Alegre/RS • Brasil
Tel: 55 51 3337.1999
Fax: 55 51 3337.1923
http://www.digitel.com.br
E-mail: info@digitel.com.br
• General guidelines
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



• Before using the equipment, please read all general information and installation instructions in this manual.



• Disconnect the equipment before cleaning it. Do not use liquids, pastes, aerosols or abrasive products; use a soft cloth, dry or slightly


moistened. Never let any objects or substances fall inside the equipment through its openings.


• Do not expose your equipment to rain or humidity levels and temperature variations beyond those specified in this manual.



• Make sure that the connections of plugs, connectors, cables and accessories comply with the technical specifications presented in


this manual. Check whether these connections are correctly and firmly plugged. Always turn off the equipment before making any



connections and installing peripherals or accessories.


• You may insert some products manufactured by Digitel into cabinets or sub-racks without having to disconnect them. To do so, follow


the instructions on Product Installation.



• Do not overload the power feeding plugs. If you need to use an extension cord, make sure to use a cord and a plug that are compatible


with those used by the equipment.



• Digitel provides technical support services all over the country, which include: preventive and remedial maintenance, installation and


version upgrades. It is essential that all repairs, including those performed after the warranty has expired, be performed at a Digitel


Technical Support Center.



• If you have to replace equipment parts or components, always use original parts. If you have questions and doubts, contact our


Technical Support Center.



• Take the necessary measures concerning antistatic and surge protection by grounding wires, using power supply filters, voltage


stabilizers and no-breaks.



• In case of cabinets, always mount them on a firm and flat surface. Cabinet slots and openings are meant to avoid overheating.


Therefore, these openings can not be blocked or covered. Make sure there are at least 3.5 cm of free space above the cabinet; never


stack the equipment.



• Digitel has the right to change the specifications presented in this manual without prior notice.



For information on warranty and technical support, see the section at the end of this manual.



ATTENTION!



This equipment uses laser emitters. Direct exposure of the eyes to the beam from connectors when they are disconnected


and unprotected may result in irreversible sight damage. Make sure optical connectors that are not in use are protected.


Dust particles or inadequate insertion of connectors may harm lase alignment.


3
• Table of contents
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

• Overview ...................................................................................................................... 8
FEATURES ................................................................................................................................................................................................... 8
Subrack model ...................................................................................................................................................................................... 9
Cabinet model ....................................................................................................................................................................................... 9
BENEFITS .................................................................................................................................................................................................... 9

• Metrofiber family components ................................................................................. 10


SUBRACK MODEL SYSTEM .................................................................................................................................................................... 10
Modem modules .................................................................................................................................................................................. 10
Management modules - MF/SNMP .................................................................................................................................................... 19
Power supply modules ........................................................................................................................................................................ 21
Chassis - MF/SUB ............................................................................................................................................................................... 22
Connection panels .............................................................................................................................................................................. 23
Accessories ......................................................................................................................................................................................... 24
CABINET MODULE SYSTEM ................................................................................................................................................................... 25
Modems ............................................................................................................................................................................................... 25
Interface modules ............................................................................................................................................................................... 31

• Product features ........................................................................................................ 39


AGGREGATE INTERFACE ....................................................................................................................................................................... 39
OPTICAL INTERFACE OPTIONS ............................................................................................................................................................. 39
TRIBUTARY INTERFACE .......................................................................................................................................................................... 46

4
Table of contents
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



V.35/V.36 INTERFACE ............................................................................................................................................................................... 47



ASYNCHRONOUS OPERATION .............................................................................................................................................................. 49



FRAMER G.704 ......................................................................................................................................................................................... 49



CROSS-CONNECTING E1 TIMESLOTS ................................................................................................................................................. 51


MODEM LIGHT INDICATORS .................................................................................................................................................................. 54



TESTING FACILITIES ............................................................................................................................................................................... 55



Local Digital Loop (LDL) ..................................................................................................................................................................... 55



Remote digital loop (RDL) ................................................................................................................................................................... 56


TEST KEY ................................................................................................................................................................................................... 57



REDUNDANT POWER SUPPLY ............................................................................................................................................................... 57



MANAGEMENT SYSTEM .......................................................................................................................................................................... 58



• Configuration/operation .............................................................................................59



CONFIGURATION VIA CLI ....................................................................................................................................................................... 59



CONFIGURATION COMMANDS .............................................................................................................................................................. 60



Configuration parameters ................................................................................................................................................................... 66



Model ................................................................................................................................................................................................... 66


Swversion ............................................................................................................................................................................................ 68


Hwversion ............................................................................................................................................................................................ 69



TstKey ................................................................................................................................................................................................... 70


AgrStatus ............................................................................................................................................................................................. 71



Tslot ...................................................................................................................................................................................................... 72


Subch ................................................................................................................................................................................................... 73




5
Table of contents
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

TrbEnable ............................................................................................................................................................................................. 74
TrbStatus .............................................................................................................................................................................................. 75
TrbTest .................................................................................................................................................................................................. 76
TrbName .............................................................................................................................................................................................. 77
VEnable ................................................................................................................................................................................................ 78
VStatus ................................................................................................................................................................................................. 79
Vmode .................................................................................................................................................................................................. 80
Vck ....................................................................................................................................................................................................... 81
Vckinv ................................................................................................................................................................................................... 82
Vtest ..................................................................................................................................................................................................... 83
VCT140EN ........................................................................................................................................................................................... 84
VCT141EN ........................................................................................................................................................................................... 85
VRDLAccept ......................................................................................................................................................................................... 86
GStatus ................................................................................................................................................................................................ 87
Gmode ................................................................................................................................................................................................. 88
Gck ....................................................................................................................................................................................................... 89
Gtss ...................................................................................................................................................................................................... 90
Gtsn ...................................................................................................................................................................................................... 91
ModEnable ........................................................................................................................................................................................... 92
ModStatus ........................................................................................................................................................................................... 93
ModTest ............................................................................................................................................................................................... 95
Zin ........................................................................................................................................................................................................ 96
TxGain .................................................................................................................................................................................................. 97
RxGain ................................................................................................................................................................................................. 98
RingFreq ............................................................................................................................................................................................... 99
TaxMode ............................................................................................................................................................................................ 100
HotLine ............................................................................................................................................................................................... 101

6
Table of contents
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Cbit ..................................................................................................................................................................................................... 102



Dbit ..................................................................................................................................................................................................... 103


EXAMPLES OF CONFIGURATION ........................................................................................................................................................ 104



SOFTWARE UPDATE VIA CONSOLE PORT ......................................................................................................................................... 116


SOFTWARE UPDATE VIA MANAGEMENT SYSTEM ............................................................................................................................ 129



• Applications .............................................................................................................. 120




• Specifications ........................................................................................................... 123



SUBRACK MODEL .................................................................................................................................................................................. 123



CABINET MODEL ................................................................................................................................................................................... 127



• Purchasing information ........................................................................................... 131




• Technical assistance and warranty ......................................................................... 135




















7
• Overview
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

The Metrofiber family is a PDH multiplexing technology based line of optical modems that allow for transporting up to four
2 Mbps E1 beams in a single optical aggregate.
It is an innovative project that blends state of the art technology and an advanced design, resulting in highly reliable, flexible
and compact products. Metrofiber is the ideal solution for small and medium capacity optical loops.
The solutions offered are aimed at operator installations and multi interface data terminals.

FEATURES

• Broad variety of optical interfaces;


• Transport capacity in one, two or four E1 timeslots aggregate;
• One, two or four G.703 tributary interfaces at 2 Mbps.
8
Overview
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Subrack model





• 19” x 3 UR subrack with capacity of up to 20 modems, power supply and management module;



• Redundant power supply;



• SNMP management;



• Secure software updates;



Patch panel for connecting tributary interfaces in 2 and 4E1 models.





Cabinet model





• One V.35/V.36 Nx64 serial synchronous interface (N=1..32), according to G.704;



• Two slots for optional interface modules;



• Cross-connection of E1 timeslots for the electrical interfaces;



• Management through the subrack model or via console.





BENEFITS





• Compact size with up to 80 E1 ports in a single 3 UR subrack (MF4E1 modems);



• Easy to configure and install;



• Integrated network management.


9
• Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

SUBRACK MODEL SYSTEM

This solution is aimed at transporting E1 beams, allowing for a large concentration of ports per subrack. It comprises
modem modules, management modules, chassis and connection panels.

Modem modules

MF4E1

• Description: Board type optical modem.

• Transport capacity: four E1 beams at 2 Mbps.

• Tributary interfaces: four E1 type electrical interfaces at 2 Mbps for coaxial cables (75 ohms) or twisted pair (120
ohms). The tributary interface connection is done through an adaptor panel (patch panel).

• Aggregate interface: optical interface with laser type emitter/receiver (the available options are descried in the Product
featureschapter further on).

10
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



The MF4E1 subrack model allows for the individual configuration or each tributary to operate with coaxial cables (75 ohms)



or twisted pair (120 ohms). For such, the straps need to be configured as shown in the following table:





Position of straps



75 ohm 120 ohms



Tr i b - 1 S2 1-2 2-3



S3 1-2 2-3



S13 1-2 2-3



Tr i b - 2 S4 1-2 2-3



S5 1-2 2-3



S11 1-2 2-3



Tr i b - 3 S6 1-2 2-3



S7 1-2 2-3



S12 1-2 2-3



Tr i b - 4 S8 1-2 2-3



S9 1-2 2-3



S13 1-2 2-3








11
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

The position of the SW1 dip-switch keys (UP/DOWN) is indicated on the board, and their functions are described below:

Configuration SW1

1 DOWN Normal operation


UP Enables software upgrades via auxiliary console.
2 DOWN Enables management and configuration via MF/SNMP module. In this case, keys 3, 4, 5,
and 6 are ignored.
UP Disables management via MF/SNMP module. Tributary enabling is then performed by keys
3, 4, 5, and 6. The other equipment options take on the default value.
3 DOWN Enables tributary 1.
UP Disables tributary 1.
4 DOWN Enables tributary 2.
UP Disables tributary 2.
5 DOWN Enables tributary 3.
UP Disables tributary 3.
6 DOWN Enables tributary 4.
UP Disables tributary 4.
7 DOWN Reserved
8 DOWN Reserved

See the Product feature chapter for further information about the modem light indicators.

12
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



The following table presents the G.703 tributary connector pinout:



Connector HD26



Pin Function



18 IN-1 Tip



9 IN-1 Ring


17 OUT-1 Tip



8 OUT-1 Ring



16 IN-2 Tip



7 IN-2 Ring


15 OUT-2 Tip



6 OUT-2 Ring



13 IN-3 Tip



4 IN-3 Ring


12 OUT-3 Tip



3 OUT-3 Ring



11 IN-4 Tip



2 IN-4 Ring


10 OUT-4 Tip



1 OUT-4 Ring



19,20,21,22,23,24,25,26 FGND



Obs.: When the interface is of 75 ohms, the RING terminal must be connected to the coaxial cable mesh.




13
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

MF2E1

• Description: Board type optical modem.

• Transport capacity: two E1 beams at 2 Mbps.

• Tributary interfaces: two E1 type electrical interfaces at 2 Mbps for coaxial cables (75 ohms) or twisted pair (120 ohms).
The tributary interface connection is done through an adaptor panel (patch panel).

• Aggregate interface: optical interface with laser type emitter/receiver (the available options are descried in the Product
featureschapter further on).
The MF2E1 subrack model allows for the individual configuration or each tributary to operate with coaxial cables (75 ohms)
or twisted pair (120 ohms). For such, the straps need to be configured as shown in the following table:
Position of straps

75 ohms 120 ohms


Tr i b - 1 S2 1-2 2-3
S3 1-2 2-3
S10 1-2 2-3
Tr i b - 2 S4 1-2 2-3
S5 1-2 2-3
S11 1-2 2-3

14
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



The position of the SW1 dip-switch keys (UP/DOWN) is indicated on the board, and their functions are described below:




Configuration SW1



1 DOWN Normal operation



UP Enables software upgrades via auxiliary console.



2 DOWN Enables management and configuration via MF/SNMP module. In this case, keys 3 and



4 are ignored.



UP Disables management via MF/SNMP module. Tributary enabling is then performed by


keys 3 and 4. The other equipment options take on the default value.



3 DOWN Enables tributary 1.



UP Disables tributary 1.



4 DOWN Enables tributary 2.



UP Disables tributary 2.



5 DOWN Reserved



6 DOWN Reserved



7 DOWN Reserved



8 DOWN Reserved



See the Product feature chapter for further information about the modem light indicators.








15
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

The following table presents the G.703 tributary connector pinout:

Connector HD26
Pin Function
18 IN-1 Tip
9 IN-1 Ring
17 OUT-1 Tip
8 OUT-1 Ring
16 IN-2 Tip
7 IN-2 Ring
15 OUT-2 Tip
6 OUT-2 Ring
19,20,21,22,23,24,25,26 FGND
Obs.: When the interface is of 75 ohms, the RING terminal must be connected to the coaxial cable mesh.

16
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



MF1E1















• Description: Board type optical modem.



• Transport capacity: one E1 beam at 2 Mbps.




• Tributary interfaces: one E1 type electrical interface at 2 Mbps for coaxial cables (75 ohms) or twisted pair (120 ohms).


The tributary interface connection is done through connectors installed directly in the module front panel.



Aggregate interface: optical interface with laser type emitter/receiver (the available options are descried in the Product



featureschapter further on).



On the MF1E1 subrack model, the tributary does not require configuration for operation with either coaxial cables (75


ohms) on connectors BNC or IEC, or for twisted pair (120 ohms) on connector RJ45. Simply use the desired interface directly by



connecting the cables to the corresponding connectors.











17
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

The position of the SW1 dip-switch keys (UP/DOWN) is indicated on the board, and their functions are described below:

Configuration SW1

1 DOWN Normal operation


UP Enables software upgrades via auxiliary console.
2 DOWN Enables management and configuration via MF/SNMP module. In this case, key 3 is ignored.
UP Disables management via MF/SNMP module. Tributary enabling is then performed by key
3. The other equipment options take on the default value.
3 DOWN Enables tributary 1.
UP Disables tributary 1.
4 DOWN Reserved
5 DOWN Reserved
6 DOWN Reserved
7 DOWN Reserved
8 DOWN Reserved

See the Product feature chapter for further information about the modem light indicators.

18
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Management module - MF/SNMP












SNMP management module for MF/SUB subrack. Supports a 10/100 Mbps Ethernet interface to connect to the management


system, one console to connect an asynchronous terminal with the 57600bps, 8, N, 1 configuration, and an output and input



connector for dry contact alarms. The SNMP management module communicates with all the subrack modems by means of an


internal RS485 serial channel, which allows for accessing each local or remote channel independently.



It featues four indicator leds with the following functions:



PWR:: power supply.



ETH:: Ethernet port activity and collision.



485:: internal 485 bar activity.



ST:: board status.



It is possible to perform the initial configuration through the management board console. The commands are described in


the management module manual. It is also possible to directly configure and monitor the local and remote modems, which is



done as follows:



• Once the management board is started, the “MetroSNMP login:>” prompt appears on the console requesting the



factory default user, which is “metrosnmp”.



• After typing in the user the default factory password is requested, “password:>” , which is “digitel”.




19
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

• After this, the prompt “MetroSNMP>” appears on the console, indicating that the board is able to receive commands
for its configuration or for accessing the modems.

• By typing “open local 3”, direct access is possible to the modem inserted in slot 3 of the subrack, where it is
possible to type in any configuration or monitoring command. After the command, the console prompt changes
indicating with which equipment it is connected (in this case, “MetroSNMP:local:3>”).

• For the remote modem connected to the modem in slot 3 of the subrack, the operation is analog, and the command
“open remote 3” must be used. At the prompt, “MetroSNMP:remote:3>” appears.

• To return to the management board console, simply type “close”, and the prompt returns to “MetroSNMP>”.
To configure the operation mode, the MF/SUB management module has a dip-switch that, in normal operation, should
have all keys in the ON position (opposite direction to the board edge). To operate in any different module, see the management
module manual.
The alarm connector has one dry output and two dry contact inputs available that can be associated to some alarm
configured in the SNMP management system. The output and two inputs correspond to MIB variables that can be activated or
read as the management application deems necessary. The alarm connector pinout is:

DB9 Function
1 and 6 Dry contact output normally closed
4 and 8 Dry contact input 0
5 and 9 Dry contact input 1
2, 3 and 7 Not connected

20
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Power supply modules





MF/AC




Power supply module for MF/SUB subrack with full range AC input (93 to 253 VAC). Protected against over current and over voltage


at the outputs and input protection with fuse. Uses an ISO320 connector for power supply input.














MF/DC




Power supply module for MF/SUB subrack with DC input (36 to 60 VDC). Protected against over current and over voltage


at the outputs and input protection with fuse. Uses a COMBICOM connector for power supply input.















21
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Chassis - MF/SUB

The MF/SUB is a 19" subrack for Metrofiber family modems. Its compact and flexible design allows for the use in
applications where space and high port density per subrack are key factors for success.
• Capacity: 20 modems without power supply redundancy or 17 modems with power supply redundancy.
• Front connections.
• Front or rear fixing options.
• Supports up to 80 E1 ports with MF4E1 modems.
• Dimensions: 3 UR height, 19" height and 200 mm depth.

22
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Connection panels





MF/PPBNC




The MF/PPBNC is a panel (patch panel) that features all the physical connections required to install up to eight E1


interfaces. A simple and efficient alternative to terminate E1 ports from MF2E1 or MF4E1 modems in BNC type coaxial connectors.



May be used together with accessory cables CB-C/4E1/75 or CB-C/2E1/75, described further on.












MF/PPIEC




The MF/PPIEC is a panel (patch panel) that features all the physical connections required to install up to eight E1 interfaces.



A simple and efficient alternative to terminate E1 ports from MF2E1 or MF4E1 modems in IEC type coaxial connectors. May be


used together with accessory cables CB-C/4E1/75 or CB-C/2E1/75, described further on.













23
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

MF/PPRJ

The MF/PPRJ is a panel (patch panel) that features all the physical connections required to install up to eight E1 interfaces. A simple and
efficient alternative to terminate E1 ports from MF2E1 or MF4E1 modems in connectors for RJ45 type twisted pair. May be used together with
accessory cables CB-C/4E1/120 or CB-C/2E1/120, described further on.

Accessories
CB-C/4E1/75
Coaxial cable with 75-ohm impedance to connect MF4E1 modems to connection panels type MF/PPIEC or MF/PPBNC.

CB-C/2E1/75
Y-type coaxial cable with 75-ohm impedance to connect two MF2E1 modems to connection panels type MF/PPIEC or MF/
PPBNC.

CB-C/4E1/120
Twisted cable with 120-ohm impedance to connect MF4E1 modems to connection panels type MF/PPRJ.

24
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



CB-C/2E1/120




Y-type twisted cable with 120-ohm impedance to connect two MF2E1 modems to connection panels type MF/PPRJ.





CABINET MODULE SYSTEM




This solution is aimed to terminate optical accessories that offers a broad range of data interfaces for simultaneous


transportation of voice, data, and internet. Comprises modems and interface modules.





Modems





MF4E1/GB












• Description: cabinet type optical modem;




• Transport capacity: four E1 beams at 2 Mbps;



• Two E1 type tributary electrical interfaces at 2 Mbps for coaxial cables (75 ohms) or twisted pair (120 ohms);




• One V.35/V.36 Nx64 serial synchronous interface (N=1..32), according to G.704;


25
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

• Two slots for optional modules;

• Aggregate interface: optical interface with laser type emitter/receiver (the available options are descried in the Product
featureschapter further on).
The SW1 dip-switch is located in the front panel, and its functions are described below:

Configuration SW1

1 DOWN Normal operating mode. The console stays in CLI mode.


UP Starts the software updating process. The console stays in the transfer state.
2 DOWN Reserved
3 DOWN Reserved
4 DOWN Reserved
5 DOWN Reserved
6 DOWN Reserved
7 DOWN Reserved
8 DOWN 57600 bps speed at the console.
UP 9600 bps speed at the console.

26
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



On the MF4E1 cabinet model, the tributary does not require configuration for operation with either coaxial cables (75



ohms) on connectors BNC or IEC, or for twisted pair (120 ohms) on connector RJ45. Simply use the desired interface directly by


connecting the cables to the corresponding connectors. For example, when using the interface with connectors for 75 ohms, the


RJ45 connector must remain disconnected (the same applies for the inverted situation).



See the Product features chapter for further information about the modem light indicators.





MF2E1/GB













• Description: cabinet type optical modem;




• Transport capacity: two E1 beams at 2 Mbps;



• Two E1 type tributary electrical interfaces at 2 Mbps for coaxial cables (75 ohms) or twisted pair (120 ohms);




• One V.35/V.36 Nx64 serial synchronous interface (N=1..32), according to G.704;



• Two slots for optional modules;




• Aggregate interface: optical interface with laser type emitter/receiver (the available options are descried in the Product


featureschapter further on).




27
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

The SW1 dip-switch is located in the front panel, and its functions are described below:

Configuration SW1

1 DOWN Normal operating mode. The console stays in CLI mode.


UP Starts the software updating process. The console stays in the transfer state.
2 DOWN Reserved
3 DOWN Reserved
4 DOWN Reserved
5 DOWN Reserved
6 DOWN Reserved
7 DOWN Reserved
8 DOWN 57600 bps speed at the console.
UP 9600 bps speed at the console.

28
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



On the MF2E1 cabinet model, the tributary does not require configuration for operation with either coaxial cables (75



ohms) on connectors BNC or IEC, or for twisted pair (120 ohms) on connector RJ45. Simply use the desired interface directly by


connecting the cables to the corresponding connectors. For example, when using the interface with connectors for 75 ohms, the


RJ45 connector must remain disconnected (the same applies for the inverted situation).



See the Product features chapter for further information about the modem light indicators.







MF1E1/GB












• Description: cabinet type optical modem;



Transport capacity: one E1 beam at 2 Mbps;




• One E1 type tributary electrical interface at 2 Mbps for coaxial cables (75 ohms) or twisted pair (120 ohms);



• One V.35/V.36 Nx64 serial synchronous interface (N=1..32), according to G.704;




• Two slots for optional modules;



• Aggregate interface: optical interface with laser type emitter/receiver (the available options are descried in the Product



featureschapter further on).



29
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

The SW1 dip-switch is located in the front panel, and its functions are described below:

Configuration SW1

1 DOWN Normal operating mode. The console stays in CLI mode.


UP Starts the software updating process. The console stays in the transfer state.
2 DOWN Reserved
3 DOWN Reserved
4 DOWN Reserved
5 DOWN Reserved
6 DOWN Reserved
7 DOWN Reserved
8 DOWN 57600 bps speed at the console.
UP 9600 bps speed at the console.

On the MF1E1 cabinet model, the tributary does not require configuration for operation with either coaxial cables (75
ohms) on connectors BNC or IEC, or for twisted pair (120 ohms) on connector RJ45. Simply use the desired interface directly by
connecting the cables to the corresponding connectors. For example, when using the interface with connectors for 75 ohms, the
RJ45 connector must remain disconnected (the same applies for the inverted situation).
See the Product features chapter for further information about the modem light indicators.

30
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Interface modules





The interface modules available for customizing functionalities on MF4E1/GB, MF2E1/GB or MF1E1/GB modems are


described below. All modems feature two slots and support any combination of modules. The modules are optional and must be


specified when purchasing the product (they can not be installed in the field).





FS













Description: module with one FXS type voice interface.



Connector: RJ11 to connect to a standard telephone set.



Features:



• Battery voltage and signal current generator (ring signal);



Line impedance configurable at 600 or 900 ohms;




• Supports public telephone with billing mode by inversion of line polarity, 12 kHz tone or 16 kHz tone;



• Programmable transmission and receiving gains between -4 dB and +4 dB, in 1 dB increments;





31
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

• Telephone signalling according to TELEBRAS 220-550-704 practice;

• Dedicated point-to-point telephone loop (hot-line);

• Caller ID support.
The FXS module board features a led with the RJ11 connector to indicate the following situations:
Lit up, green: indicates the telephone set is of the hook.
Flashing, green: flashes with the ring cadence or during decadic pulse dialling.
The RJ11 connector has pin 3 connected to the TIP signal and pin 2 connected to the RING signal. This pinout allows for
connection of the modem to a telephone set through a direct, standard cable.
The console parameters pertaining to the configuration and operation of this module are: modstatus, modenable,
zin, txgain, rxgain, ringfreq, taxmode, hotline, cbit and dbit.
This voice module uses a single 64 kbps timeslot from the E1 to which it is associated, and can only be used by employing
the internal G.704 framer. The following parameters are made compulsory: “set subch[1 ou 2]=yes”; “set gtsn[1 ou
2]=1”; “set gmode=PCM30 or PCM30C”.
For further information about the possibilities of using this module, see the Applications and Examples of Configuration
items at the end of this manual.

32
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



FO











Description: module with one FXO type voice interface.



Connector: RJ11 to connect to the telephone network.



Features:



• Current retention and signal current detection (ring signal);



• Line impedance configurable at 600 or 900 ohms;




• Supports public telephone with billing mode by inversion of line polarity, 12 kHz tone or 16 kHz tone;



• Programmable transmission and receiving gains between -4 dB and +4 dB, in 1 dB increments;



• Telephone signalling according to TELEBRAS 220-550-704 practice;



Caller ID support.



The FXO module board features a led with the RJ11 connector to indicate the following situations:




Lit up, green: indicates the telephone set is of the hook.



Flashing, green: flashes with the ring cadence or during decadic pulse dialling; goes off during billing pulse detection.






33
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

The RJ11 connector has pin 3 connected to the TIP signal, and pin 2 connected to the RING signal.
The console parameters pertaining to the configuration and operation of this module are: modstatus, modenable,
zin, txgain, rxgain, taxmode, cbit and dbit.
This voice module uses a single 64 kbps timeslot from the E1 to which it is associated, and can only be used by employing
the internal G.704 framer. The following parameters are made compulsory: “set subch[1 ou 2]=yes”; “set gtsn[1 ou
2]=1”; “set gmode=PCM30 or PCM30C”.
For further information about the possibilities of using this module, see the Applications and Examples of Configuration
items at the end of this manual.

RO

Description: Ethernet module with IP routing capacity.


10/100 Base T Ethernet Interface.
Connector: female RJ45 UTP without crossover function.
WAN interface: one 64 kbps WAN port at 2.048 MBPS connected to the optical interface.

34
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Configuration: asynchronous CLI via console, CLI via Ethernet or graphic configuration application (EasyConfig).



Protocols: PPP, PPP-HDLC, PPP-IPCP, FRAME RELAY, SNMP-TRAPS, MIB-II, IP-CMPRS, Bridge, TFTP, PAP, CHAP, NAT,



SNMP, SMI, RIP, FTP, IP-E, ARP, TCP, ICMP, IP, UDP, OSPF, RIPII, TELNET, DNS, VRRP.



The Router module board features two leds with the RJ45 connector to indicate the following situations:



STATUS:



Red: startup phase after power-on (this phase takes approximately 1 minute).



In case there are any problems at startup or during operation of the equipment, the led stays red.



Green: normal operation.



ETHERNET:



Green: loop established at 10 Mbps, with no network activity.



Red: loop established at 100 Mbps, with no network activity.



Flashing, green:loop established at 10 Mbps, with network activity.



Flashing, red: loop established at 100 Mbps, with network activity.



The LAN interface may be connected to hubs or switches using direct cables, or to microcomputers through crossover


cables.



The console parameters pertaining to the configuration and operation of this module are: modstatus and modenable.



For more detailed information about the operation and facilities of this module, see the specific manual.



For further information about the possibilities of using this module, see the Applications and Examples of Configuration



items at the end of this manual.





35
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

BG

Description: remote Bridge module.


Data interface: One 10/100 Mbps Ethernet.
WAN interface: 1 to 4 2.048 Mbps WANs connected to the optical interface. When only one WAN is used, it can be
configured from 64 kbps to 2.048 Mbps.
The function of this Bridge module is to interconnect two segments of an Ethernet network (LAN) through one or more
WAN interfaces. It functions as a remote Bridge, with one Bridge module being required at each end of the connection. Since it
operates only at the MAC level, it functions in a transparent way for superior layer protocols, such as IP, IPX, NetBEUI, etc.
Its main function is to segment the local network not allowing all the traffic to pass from one segment to another, thus
making more efficient use of the WAN band.
For such, the module receives the packets from the LAN interface and only sends them to the WAN if they are free of errors,
are destined to stations located at the other end of the loop or in case of Broadcasts and Multicasts.
The module automatically learns which addresses belong to each side of the loop and, in case a station remains inactive
for over 5 minutes, it is automatically removed from the address table. This process does nor require configuration by the user
and does not limit the maximum available band.
The module also features a buffer capable of storing 572 packets of 1522 bytes (supporting VLAN) to compensate the rate
difference between LAN and WAN.

36
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



The Bridge may be connected to hubs, switches and routers through direct cables, or to micorcomputers through cross



cables.



The console parameters pertaining to the configuration and operation of this module are: modstatus and modenable.



For further information about the possibilities of using this module, see the Applications and Examples of Configuration


items at the end of this manual.





G3














Description: G.703 module at 2.048 Mbps.



Interface: one E1 type electrical interface at 2,048 Mbps for coaxial cables (75 ohms) or for twisted pair (120 ohms).



Connector: BNC or IEC for 75 ohms and RJ45 for 120 ohms.




This module is aimed at expanding the cabinet G.703 interfaces, thus allowing to attain four E1 interfaces on the MF4E1/GB


modem models. It is supplied with BNC and RJ45 or IEC and RJ45 connectors, according to the modem model. It may be


comprised according to information contained in the Purchasing information item, at the end of this manual.



The operation of this interface is similar to the resident interfaces on the cabinet model, the module does not require



configuration for operation with either coaxial cables (75 ohms) on connectors BNC or IEC, or for twisted pair (120 ohms) on



37
Metrofiber family components
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

connector RJ45. Simply use the desired interface directly by connecting the cables to the corresponding connectors. For
example, when using the interface with connectors for 75 ohms, the RJ45 connector must remain disconnected (the same applies
for the inverted situation).
Timeslot mapping on the module is also done through the “Tslot” console parameter, but using arguments “mod1” or
“mod2” instead of “trib1” and “trib2”.
The console parameters pertaining to the configuration and operation of this module are: modstatus, modenable and
modtest.
For further information about the possibilities of using this module, see the Applications and Examples of Configuration
items at the end of this manual.

38
• Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



AGGREGATE INTERFACE





The Metrofiber family products feature an optical aggregate interface to connect with the remote equipment. The product


uses a multiplexing structure based on PDH technology with a signalling rate at the fiber of 68.783 Mbps. A proprietary configuration


is used aimed ar ensuring high performance, regardless of the standard used. The optical interface is compatible with all the



Metrofiber family models, allowing devices of different transport capacity to be used in the same loop.




OPTICAL INTERFACE OPTIONS





The table below shows the optical interface options available for the Metrofiber family. Other types of interface may be


supplied upon request. Please contact Digitel technical support for information about the availability and specific applications.






Interface Description Features



SP3 Optical interface with transmission on two • Type of fiber: single mode (9/125 um),


single mode fibers, one for transmission ITU-T G.652 standard



the other for reception, in the 1310 nm window, • Connector: SC/PC, SC/UPC or SC/


APC operating with SC connectoring. • Transmitter optical window: 1310 nm


• Receiver optical window: 1310 nm



• Type of emitter: laser


• Emitter spectrum width: 4 nm


• Transmitted optical power:



SC/PC or SC/UPC: >-6 dBm


SC/APC: >-15 dBm





39
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Interface Description Features


SP3 (cont.) • Receiver sensitivity:
SC/PC or SC/UPC: <-37 dBm
SC/APC: <-37 dBm
• Dynamic range:
SC/PC or SC/UPC: >31 dB
SC/APC: >22 dB
• Estimated range:
SC/PC or SC/UPC: 81 km
SC/APC: 58 km
SP3M Optical interface using two MULTIMODE Type of fiber: MULTIMODE
optical fibers with SC connectoring. It uses one Connector: SC/PC, SC/UPC or SC/APC
fiber for transmission and the other for Transmitter optical window: 1310nm
reception. It operates by transmitting an optical Receiver optical window: 1310nm
signal in the 1310 nm window Type of emitter: laser FP
Emitter spectrum width: 8nm
Transmitted optical power:
SC/PC or SC/UPC: >-19 dBm
SC/APC: >-28 dBm
Receiver sensitivity:
SC/PC or SC/UPC: >-32 dBm
SC/APC: >-32 dBm
Dynamic range:
SC/PC or SC/UPC: >-13 dBm
SC/APC: >-4 dBm
Estimated range for typical loop, (with
loss of 0.5 dB/km and passing Band of
500 MHz.km@1310nm ): 2km

40
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○




Interface Description Features



SAM3 Optical interface with transmission and reception • Type of fiber: single mode (9/125 um),


in only one single mode fiber, operating in the ITU-T G.652 standard



1310 nm window, both for output signal • Connector: SC/APC


and input signal, with SC/APC connectoring. • Transmitter optical window:1310 nm


This optical interface requires the use of • Receiver optical window: 1310 nm



connectors with polishing of APC type in the • Type of emitter: laser


whole optical loop, in order to maintain optical • Emitter spectrum width: 4 nm


reflection at adequate levels. • Transmitted optical power: >-11 dBm


• Receiver sensitivity: <-33 dBm



• Dynamic range: >-22 dB


• Estimated range: 57 km



EM3 Optical interface with transmission and reception • Type of fiber: single mode (9/125 um),


in only one single mode fiber, operating in the ITU-T G.652 standard


1310 nm window, both for output signal • Connector: E2000



and input signal, with E2000 • Transmitter optical window: 1310 nm


connectoring. This optical interface requires the • Receiver optical window: 1310 nm


use of connectors with polishing type • Type of emitter: laser



APC in the whole optical loop, in order to maintain • Emitter spectrum width: 4 nm


optical reflection at adequate levels. • Transmitted optical power: >-11 dBm


• Receiver sensitivity: <-33 dBm



• Dynamic range: >-22 dB


• Estimated range: 57 km









41
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Interface Description Features


SP5 Optical interface with transmission • Type of fiber: single mode (9/125 um)
in two single mode fibers, one ITU-T G.652, ITU-T G.653 or ITU-T G.655
for transmission and the other for standard
reception, operating in the • Connector: SC
1550 nm window, with SC • Transmitter optical window: 1550 nm;
connectors. • Receiver optical window: 1550 nm
• Type of emitter: laser DFB
• Emitter spectrum width: 1 nm
• Transmitted optical power:
SC/PC or SC/UPC: >-5 dBm
SC/APC: >-14 dBm
• Receiver sensitivity:
SC/PC or SC/UPC: <-35 dBm
SC/APC: <-34 dBm
• Dynamic range:
SC/PC or SC/UPC: >-30 dB
SC/APC: >-20 dB
• Estimated range for typical loop:
SC/PC or SC/UPC: 120 km
SC/APC: 80 km

42
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○




Interface Description Features



FCP3 Optical interface that uses two single mode • Type of fiber: single mode (9/125 um),


optical fibers (9/125 um) with FC connectoring. ITU-T G.652 standard



Uses one fiber for transmission and the other • Connector: FC


for reception. Operates transmitting and • Transmitter optical window: 1310nm



receiving optical signal in the 1310 nm • Receiver optical window: 1310nm


window. • Type of emitter: laser FP


• Emitter spectrum width: 4nm



• Transmitted optical power: >-6 dBm


• Receiver sensitivity: <-37 dBm


• Dynamic range: > 31dB



• Estimated range for typical loop: 81 km


FC5D Optical interface that uses two single mode • Type of fiber: single mode (9/125 um),



optical fibers (9/125 um) with FC connectoring. ITU-T G.652, ITU-T G.653 or ITU-T G.655


It uses on fiber for transmission and the other ITU-T G0.655


for reception. Operates transmitting and • Connector: FC



receiving optical signal in the 1550 nm window. • Transmitter optical window: 1550nm


• Receiver optical window: 1550nm


• Type of emitter: laser DFB



• Emitter spectrum width: 1nm



• Transmitted optical power:> -5 DBM



• Receiver sensitivity: <-35 DBM


• Dynamic range: > 30dB



• Estimated range for typical loop:


120 km




43
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Interface Description Features


SC35 Optical interface with transmission and reception • Type of fiber: single mode (9/125 um),
in only one single mode fiber (9/125 um) ITU-T G.652 standard
with SC connectoring. Operates transmitting • Connector: SC/PC, SC/UPC or
optical signal in the 1310 nm window and SC/APC
receiving in the 1550 nm window. • Transmitter optical window: 1310nm
Therefore, this module must operate in • Receiver optical window: 1550nm
association with its complementary module, • Type of emitter: laser FP
installed at the other end of the optical fiber • Emitter spectrum width: 4nm
(in this case, modem with SC53 interface). • Transmitted optical power:
With this optical interface, operates with two SC/PC or SC/UPC: >-6.5 dBm
wave lengths, and supports operation in SC/APC: >-15 dBm
optical loops that contain connectors • Receiver sensitivity:
with polishing type PC. SC/PC or SC/UPC: <-30 dBm
The main limiting factor in the range of this SC/APC: <-30 dBm
optical interface is due to the chromatic • Estimated range for typical loop: 40 km
dispersion in one optical fiber being different
for both different wave lengths.

44
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○




Interface Description Features



SC53 Optical interface with transmission and reception • Type of fiber: single mode (9/125 um),


in only one single mode fiber (9/125 um), ITU-T G.652 standard



with SC connectoring. Operates transmitting • Connector: SC/PC, SC/UPC or


optical signal in the 1550 nm window and receiving SC/APC


in the 1310 nm window. • Transmitter optical window: 1550nm



Therefore, this module must operate in • Receiver optical window: 1310nm


association with its complementary module, • Type of emitter: laser FP


installed at the other end of the optical fiber • Emitter spectrum width: 4nm


(in this case, modem with SC35 interface). • Transmitted optical power:



With this optical interface operates with two SC/PC or SC/UPC: >-10 dBm


wave lengths, supports operation in SC/APC: >-17 dBm


optical loops that contain connectors • Receiver sensitivity:



with polishing type PC. SC/PC or SC/UPC: <-30 dBm


The main limiting factor in the range of this SC/APC: <-30 dBm


optical interface is due to the • Estimated range for typical loop: 40 km



chromatic dispersion in one optical fiber


being different for both different


wave lengths.








Note:



The estimated range for each optical interface type is calculated based on the attenuation observed in a typical


loop: 0.38 dB/km for operation in the 1310 nm window and 0.25 dB/km for operation in the 1550 nm window using



the fiber of the recommended standard.



45
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

1
8

RJ45 connector pinout


Pin 1 RX (out)
Pin 2 RX (out)
Pin 4 TX (in)
Pin 5 TX (in)

TRIBUTARY INTERFACES

The tributary interfaces of the MF4E1, MF2E1 and MF1E1 modems operate at the speed of 2 Mbps, according to
recommendation G.703. Each interface may be configured individually, locally or via management system.
The interfaces are available with connectors located in the front panel and allow for the connection of either coaxial cables
with impedance of 75 ohms or twisted pairs of 120 ohms.

46
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



V.35/V.36 INTERFACE





This interface is only available in the cabinet model. Through commands, it is possible to configure:



• Mode of operation: V.35 or V.36.



• Transmission clock: INT (internal clock), REG (slave clock) ou EXT (external clock).



• Connection to subchannel 3 from G.704 or directly to an E1 timeslot.



• Two-way local digital loop.




• Transmission clock phase: normal or inverted.



In some cases, due to the propagation time of the interface chips in the connected equipment, it becomes necessary to


invert the transmission clock phase. This is mainly observed when the clock is configured to INT or REG, and when speeds are


over 1 Mbps.



The V.35/V.36 interface connector is located in the rear panel and is of type DB25, ISO-2110 standard.






Pinout of DB25 connector - Mode V.35 or Mode V.36



Circuit Function Signal Pin DB25



101 Protection ground P.GND 1



2.52a Signal ground S.GND 7



102b Signal ground S.GND 23


103 Data to be transmitted TDa 2



TDb 14



47
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Circuit Function Signal Pin DB25

104 Received data RDa 3


RDb 16
105 Request to send RTSa 4
106 Clear to send CTSa 5
107 Modem clear DSR 6
108 Terminal clear DTR 20
109 Carrier detection DCDa 8
113 External clock for XTCa 24
transmission XTCb 11
114 Transmission clock TCa 15
TCb 12
115 Receiving clock RCa 17
RCb 9
140 Loop activation 21
141 Local loop activation 18
142 Test indicator TI 25

48
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



ASYNCHRONOUS V.28 OPERATION





It is possible to operate with a low speed, asynchronous channel through a high speed synchronous channel by


performing a data supersampling. This is done as follows:





set tslot[n]=V35 Establishes a 2Mbps timeslot for the V35 interface



set subch[3]=no Establishes a 2Mbps timeslot for the V35 interface



set Vmode=V28 Mode of operation V.28



set Venable=Yes Enables V.xx interface



set VCk=INT Configures the V.xx interface transmission clock





It is then possible to send traffic through this interface of an asynchronous data channel with speed of up to



115200 bps.





FRAMER G.704




Speeds between 64 kbps and 1.984 Mbps can be obtained from framer G.704 that allows the assembly of up to three


subchannels simultaneously from an E1 timeslot at 2 Mbps that contains an E1 signal structured in G.704.









49
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Through commands, it is possible to configure:

• Framer mode of operation: PCM30, PCM30C, PCM31 or PCM31C.

• Master clock synchronism source:

INT: internally generated clock;

REG: timeslot receiving clock connected to G.704;

EXT1: clock supplied by module 1;

EXT2: clock supplied by module 2;

EXT3: clock supplied by V.35/V.36 interface.

• Composition of each subchannel.

The composition of each subchannel is done through the indication of the 64 kbps timeslots that belong to the structured
E1 frame. The initial timeslot is indicated through command Tss[], and the number of timeslots to be used from the initial one,
through command Tsn[]. The subchannel speed will result from the number of timeslots used (example: 1 timeslot results in 64
kbps, 2 timeslots in 128 kbps, 3 in 192 kbps and then on).
Through command SubCh, the G.704 subchannels are connected to the electrical interfaces, that is: by commanding
subch[3]=yes, the V.35 interface will be connected to subchannel 3 in G.704; by commanding subch[3]=no, he V.35 interface
will be connected to the cross-connect matrix; by commanding subch[1]=yes, channel 1 of module 1 will be connected to
subchannel 1 in G.704; by commanding subch[1]=no, channel 1 of module 1 will be connected to the cross-connect matrix;
and then on.

50
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Attention must be given to the fact that there is a determined number of 64 kbps timeslots in the structured E1 board, and



that these can not be overlapped in the subchannel composition.



A structured E1 board in mode PCM31 and PCM31C comprises the first heading timeslot (timeslot 0), with timeslots 1 to


31 being available for the composition of the subchannels. The structured E1 board in mode PCM30 and PCM30C comprises the


first heading timeslot (timeslot 0) and signalling timeslot 16, with timeslots 1 to 15 and 17 to 31 being available for the composition



of the subchannels.



When using subchannel 3 in G.704 to connect to the V.35/V.36 interface, attention must be given to the transmission clock


configuration in this interface through command Vck.



For Gck = INT, REG, EXT1 or EXT2, Vck it must be INT.



For Gck = EXT3, Vck it must be EXT.







CROSS-CONNECTING E1 TIMESLOTS




In the subrack model, every timeslot available in the optical fiber has a corresponding G.703 tributary at 2 Mbps. This


situation is illustrated in the following figure.





Timeslot_1


Tributary-1 G.703


Timeslot_2


Optical Aggregate Aggregate Tributary-2 G.703


interface Timeslot_3


interface
Tributary-3 G.703



Timeslot_4
Tributary-4 G.703




51
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

For the cabinet model, up to four E1 timeslots can be connected to:


• one or two tributary interfaces;
• one V.35 or V.36 interface;
• two optional modules with up to four channels each;
• one framer G.704.

This connection possibility is due to the use of a cross-connect matrix that allows to choose an available timeslot for any
available interface. Programming is through command Tslot.

52
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



The following figure shows examples of the possible situations.






Cross-connect



(Trib1) Tributary-1 G.703



(Trib2) Tributary-2 G.703





(Mod1Ch1)


Chan-1


(Mod1Ch2)
Chan-2
Module-1



(Mod1Ch3)
Chan-3
Timeslot_1


(Mod1Ch4)
Chan-4


Timeslot_2



Timeslot_3 (Mod2Ch1)


Chan-1


Timeslot_4


(Mod2Ch2)
Chan-2 Module-2


(Mod2Ch3)


Chan-3


(Mod2Ch3)
Chan-4


Framer G.704



SubCh-1


(G704)


SubCh-2


SubCh-3
V.35 V.36



(V35)





53
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

MODEM LIGHT INDICATORS


The Metrofiber family products feature light indicators that offer a series of information with respect to operation of the
product. All modems use the same convention and functionality, although not all indicators are avaliable in all devices. The
following table describes the function and signalling options for each indicator.

Indicator Function Options


PWR Supply Red:: System startup or failure
Green:: Normal operation
OPT Optical interface Flashing red:: LOS (no signal)
Green:: Valid signal
Red:: Optical loop or invalid optical signal
G1, G2, G3, G4 Tributary interface Off:: Disabled
Green:: Ok
Red:: AIS (presence of alarm standard at the electrical input)
Flashing green:: Interface in LDL (local digital loop)
Flashing red:: LOS (lack of signal in the electrical interface)
V V.35/V.36 Interface Off:: Disabled
Green:: Ok
Red:: AIS (presence of AIS alarm at the electrical input)
Flashing green:: Interface in LDL (local digital loop)
M1, M2 Optional modules Off:: Disabled
Green:: Ok
Red:: Alarm
Flashing green:: Interface in LDL (local digital loop)
Flashing red:: LOS (lack of signal in the electrical interface)

54
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○




Indicator Function Options



ST Operating status Green:: Ok



Flashing red: Any interface enabled and in the LOS, AIS, error or alarm condition




TESTING FACILITIES



The Metrofiber family modems feature some testing facilities for data channel validation.






Local Digital Loop (LDL)





This type of test is two way, that is, transmission data from ETD are returned to the ETD receival, and data from each


timeslot from the line are returned to it.



It is available in models MF4E1, MF2E1 and MF1E1 through command “TrbTest[n]”, and the TEST key in the front panel.



On models MF4E1/GB, MF2E1/GB and MF1E1/GB through command “TrbTest[n]”, “VTest”, “ModTest”, through TEST


key in the front panel, and signal CT141 of V.35/V.36 interface, that may be enabled or not through command “VCT141EN”.



This test may be locally activated through the TEST key, signal CT141, console commands or management system. It is



alos possible, through the local modemo console port or management system, to access the remote modem and activate in it


an LDL command.










55
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Remote digital loop (RDL)

This loop applies only to the V35/V36 interface in the Cabinet models: MF4E1/GB, MF2E1/GB and MF1E1/GB, and uses
a protocol that follows the V.54 standard.
The local modem sends a loop activation sequence to the remote modem using its own V35/V36 interrface data channel.
If the remote modem is enabled to receive through command “VRDLAccept”, it will activate a loop in the V35/V36 interface data
channel. When the local modem wishes to undo this loop, it will send a deactivation sequence to the remote modem.
This type of test is also two way, that is, transmission data from ETD are returned to the ETD receival, and data from the line
are returned to it.
It is available through command “VTest” and signal CT140 of V35/V36 interface, which can be enabled or not through
command “VCT140EN”.

56
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



TEST KEY




The front panel of the modems has a contact key to perform a test in the product. By holding this key for a few seconds, all the


electrical interfaces that are enabled and connected to some E1 timeslot through the connection matrix will enter a two way LDL.





Test activation



By pressing the TEST key, the PWR led flashes quickly for a few seconds and goes off soon after. At the same time, the


OPT led will start flashing in the same cadence the PWR led was flashing. This indicates the modem has entered testing. It stays


this way even after the TEST key is released.





Test deactivation



By pressing the TEST key, the OPT led flashes quickly for a few seconds and goes off soon after. At the same time, the


PWR led will start flashing in the same cadence the OPT led was flashing. This indicates the modem has returned to normal


operation. It stays this way even after the TEST key is released.





REDUNDANT POWER SUPPLY



The Metrofiber family products meet a demand of applications that require a high rate of circuit availability by optionally



using primary power supply redundancy in the MF/SUB subrack. The same subrack supports applications without redundancy


(supply, 20 modems and management board) or with redundancy (two supplies, 17 modems and management board), with any


combination of AC or DC supplies, allowing the user any choice and changes in the reliability policy with no need to change the



basic infrastructure.








57
Product features
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

MANAGEMENT SYSTEM

The devices are managed through the DMS system (Digitel Management Suite), a proprietary management system by
Digitel S.A. Indústria Eletrônica. Communication between the management station (manager) and devices (agents) is done
through SNMP (Simple Network Management Protocol), RFC 1157.
The DMS system stores equipment information, events and statistics in a data base that may be retrieved to issue reports.
It can be used in several operating system platforms, such as, for example, Windows 95, Windows 98, Windows NT, Linux, Solaris
and HP-UX. It can also be integrated into management platforms, such as, for example, HP OpenView Network Node Manager,
IBM Tivoli Netview, among others.
Management of the Metrofiber family features an automatic identification resource of the devices that make up the loop.
Viewing and configuration can be performed individually for each device, allowing configuration of the agent, tributaries, and
aggregates in each case.
The system allows the received alarms to be viewed and sorted by severity, and that the actions be linked to its reception,
such as, for example, execution of commands, etc.
Configuration of modems installed in the MF/SUB is done in a centered way at the MF/SNMP itself. The existing configuration
system in this module allows commands to be sent to all local modems and their remote pairs. Optionally, the MF/SNMP module
may not be installed; in this case, configuration is performed in a simplified way through existing programming dip-switches in
each modem. In both cases, the configuration always remains stored in the memory of each individual unit.

58
• Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



CONFIGURATION VIA CLI





Confiration of the devices through command line interface (CLI) may be done through the console interface (RS-232) or


Ethernet (10/100 Mbps). Both have similar operation, differing only in the way of accessing the equipment. This allows for the use


or configuration files that contain a set of commands to execute a standard configuration in an equipment plant.



The management board console works with the 57600 bps, 8, N, 1 configuration. The cabinet modem console can work



with 9600 bps, 8, N, 1, or 57600 bps, 8, N, 1, according to the configuration of the dip-switch in the front panel.



The console prompt has some information about the local modem and its connection to the remote modem. For example:


[Loc@MF00.0]#, where:



“Loc” indicates the typed commands will be executed in the local modem;



“Rem” indicates the typed commands will be executed in the remote modem;



“.0” indicates the optical connection with the remote modem is interrupted;



“.1” indicates the optical connection with the remote modem has been established and that the modem takes on


address “1”;



“.2” indicates the optical connection with the remote modem has been established and that the modem takes on



address “2”.



When connecting a board model modem to another cabinet model modem, the board modem takes on address “1”,


and the cabinet modem takes on address “2”. When connecting a cabinet model modem to another cabinet model modem,


address designation takes place randomly.



“MF01” indicates the board model modem is inserted in slot 1 of the subrack, and there on up to slot 20;




“MF00” is indicated in the cabinet model console when communication with the remote one is interrupted;



“MF00” is indicated in the cabinet model console when communication with another cabinet model


modem has been established.


59
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

CONFIGURATION COMMANDS

The configuration commands act on parameters, and may change, show or store their values. The parameters can be of
two types: single and multiple.
Single parameters have only one occurrence in the equipment and do not require any additional information. Multiple
parameters occur in a repeated way, and require an identification list for their full description.
The identifier list is always between brackets, [], and may comprise a single index or an interval with beginning and end
separated by hyphens, -.
The configuration commands are presented below.
Get

Function Prints the parameter value.


Format get <parameter>
Example ↵
get model↵
model=”MF1E1-2F-1310"
Ok.

60
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Set





Function Designates a value for a parameter. In case the value contains spaces, it must be included


in quotes (“”). Note that there can not be any spaces between the parameter, the equal



signal and the value to be designated.



Format set <object>=<value>



Example ↵
set trbenable[2]=yes↵



trbenable[2]=”yes”



Ok.





Apply




Function Makes the changed values be used by the equipment. Any changes made will have no



effect until the apply command is executed. One exception are the test commands, that are


executed immediately.



Format apply



Example ↵
apply↵



Applying.....Ok









61
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Save

Function Saves the current configuration in the equipment non-volatile memory. By executing this
command, the saved parameters are immediately used by the equipment.
Format save
Example ↵
save↵
Saving....Ok

Recall

Function Retrieves the configuration from the non-volatile memory. Configurations that are not saved
will be lost. The retrieved configuration will not be active until an apply command is executed.
Format recall
Example ↵
recall↵
Loading....Ok

62
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Default





Function Returns all configurations to the factory value.



Format default



Example ↵
default↵



Loading default values....Ok







Help




Função Lists the modem console commands.



Format


help



Example help↵






GetHelp





Função Lists the modem console command parameters.



Format gethelp



Example ↵
gethelp↵



63
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

GetConf

Função Lists all the modem configurations.


Format getconf
Example ↵
getconf↵

GetMod

Função Lists all the cabinet model modem module statuses.


Format getmod
Example ↵
getmod↵

GetStat

Função Lists all the modem statuses.


Format getstat
Example ↵
getstat↵

64
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



2





Function By typing character “2” in the modem console, access is gained to the remote modem


console in case the optical connection is OK.




Format 2



Example [Loc@MF05.2]#2↵


[Rem@MF05.2]#



1





Function By typing character “1” in the modem console, access is gained once more to the local


modem console.



Format 1



Example ↵
[Rem@MF05.2]#1↵



[Loc@MF05.2]#
















65
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Configuration parameters

Model

Function Read only. Returns the product model.


Type Single
Options MF4E1-2F-1310: board, 4E1, pair of fibers, 1310 nm
MF4E1-1F-1310: board, 4E1, single fiber, 1310 nm
MF4E1-2F-1550: board, 4E1, pair of fibers, 1550 nm
MF2E1-2F-1310: board, 2E1, pair of fibers, 1310 nm
MF2E1-1F-1310: board, 2E1, single fiber, 1310 nm
MF2E1-2F-1550: board, 2E1, pair of fibers, 1550 nm
MF1E1-2F-1310: board, 1E1, pair of fibers, 1310 nm
MF1E1-1F-1310: board, 1E1, single fiber, 1310 nm
MF1E1-2F-1550: board, 1E1, pair of fibers, 1550 nm
MF4E1/GB-2F-1310: cabinet, 4E1, pair of fibers, 1310 nm
MF4E1/GB-1F-1310: cabinet, 4E1, single fiber, 1310 nm
MF4E1/GB-2F-1550: cabinet, 4E1, pair of fibers, 1550 nm
MF2E1/GB-2F-1310: cabinet, 2E1, pair of fibers, 1310 nm
MF2E1/GB-1F-1310: cabinet, 2E1, single fiber, 1310 nm
MF2E1/GB-2F-1550: cabinet, 2E1, pair of fibers, 1550 nm
MF1E1/GB-2F-1310: cabinet, 1E1, pair of fibers, 1310 nm
MF1E1/GB-1F-1310: cabinet, 1E1, single fiber, 1310 nm
MF1E1/GB-2F-1550: cabinet, 1E1, pair of fibers, 1550 nm

66
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○




Default -



Application MF4E1, MF2E1, MF1E1, MF4E1/GB, MF2E1/GB, MF1E1/GB



Example ↵
get model↵



model=”MF2E1-1F-1310"



Ok.































67
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Swversion

Function Read only. Software version code.


Type Single
Options Software version code currently being executed by the equipment.
Default -
Application MF4E1, MF2E1, MF1E1, MF4E1/GB, MF2E1/GB, MF1E1/GB
Example ↵
get swversion↵
swversion=”000.1000.00-1"
Ok.

68
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Hwversion





Function Read only. Hardware version code.



Type Single



Options Equipment hardware version code.



Default -



Application MF4E1, MF2E1, MF1E1, MF4E1/GB, MF2E1/GB, MF1E1/GB



Example ↵
get hwversion↵



hwversion=”1"



Ok.






















69
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Tstkey

Function Enables the TST key functions in the front panel.


Type Single
Options Yes: enables operation of the TST key
No: disables operation of the TST key
Default yes
Application MF4E1, MF2E1, MF1E1, MF4E1/GB, MF2E1/GB, MF1E1/GB
Example 1) Checks the TST key operation mode:

get tstkey↵
tstkey=”yes”
Ok.
2) Disables the TST key:

set tstkey=no↵
tstkey=”no”
Ok.

70
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



AgrStatus





Function Read only. Checks the optical aggregate interface status.



Type Single



Options Ok: normal operation



LOS: loss of optical signal


SyncLos: loss of synchronism of the received optical signal


OptLoop: optical loop detected in the aggregate interface due to reflections in the fiber



Default -



Application MF4E1, MF2E1, MF1E1, MF4E1/GB, MF2E1/GB, MF1E1/GB



Example 1) Checks the aggregate interface status:




get agrstatus↵



agrstatus=”LOS”



Ok.
















71
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Tslot

Function Cross-connect programming with association of timeslots to the electrical interfaces.


Type Multiple[1-n], where n=1 for 1E1 products, n=2 for 2E1 and n=4 for 4E1
Options Trib1: tributary 1 interface
Trib2: tributary 2 interface
Mod1: expansion module 1
Mod2: expansion module 2
G704: framer G.704
V35: V.35/V.36 serial interface
none: disconnected
Default none
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example ↵
set tslot[2]=V35↵
tslot[2]=”V35"
Ok.


set tslot[2]=mod1↵
tslot[2]=”MOD1"
Ok.


set tslot[1-2]=mod1↵
tslot[1]=”MOD1" TSLOT[2]=”MOD1”
Ok.

72
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Subch





Function Enables the use of G.704 subchannels and their routing up to the expansion modules and


the V.35/V.36 interface. Subchannel 1 associated to module 1, channel 1; Subchannel 2



associated to module 2, channel 1;and Subchannel 3 associated to the V.35/V.36 interface.



Type Multiple[1-3]



Options Yes: Connects the subchannel to the corresponding interface


No: Disconnects the subchannel from the corresponding interface, connecting the interface to


the cross-connect matrix




Default no



Application MF4E1/GB, MF2E1/GB, MF1E1/GB



Example set subch[2]=yes↵


subch[2]=”yes”


Ok.


















73
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

TrbEnable

Function Enables a determined tributary interface.


Type Multiple[1-n], where n=1 for 1E1 products, n=2 for 2E1, and n=4 for 4E1
Options Yes: tributary interface enabled
No: tributary interface disabled
Default Yes
Application MF4E1, MF2E1, MF1E1, MF4E1/GB, MF2E1/GB, MF1E1/GB
Example 1) Enables tributary 1 interface:

set trbenable[1]= yes↵
trbenable=”yes”
Ok.
2) Checks tributary 1 interface enabling:

get trbenable[1]↵
trbenable=”no”
Ok.

74
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



TrbStatus





Function Read only. Checks the status of a tributary interface.



Type Multiple[1-n], where n=1 for 1E1 products, n=2 for 2E1, and n=4 for 4E1



Options Ok: normal operation



LOS: loss of signal in the tributary interface


AIS: alarm signal detected in the tributary interface


Test: test activated in the data interface


Disabled: tributary interface disabled



NotAvaliable: tributary interface not available



Default -



Application MF4E1, MF2E1, MF1E1, MF4E1/GB, MF2E1/GB, MF1E1/GB



Example 1) Checks the tributary 1 interface status:




get trbstatus[1]=↵



trbstatus[1]=”Ok”



Ok.



2) Checks the tributary 2 interface status:




get trbstatus[2]↵



trbstatus[2]=”AIS”



Ok.





75
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

TrbTest

Function Activates a test loop in a tributary interface. This parameter is not saved in the equipment
non-volatile memory.
Type Multiple[1-n], where n=1 for 1E1 products, n=2 for 2E1, and n=4 for 4E1
Options None: no tetst activated
LDL: local digital loop activated in the tributary interface
Default None
Application MF4E1, MF2E1, MF1E1, MF4E1/GB, MF2E1/GB, MF1E1/GB
Example 1) Activates a local digital loop in the tributary 1 interface:

set trbtest[1]=ldl↵
trbtest[1]=”ldl”
Ok.
2) Checks the tributary 1 interface test activation:

get trbtest[1]↵
trbtest=”none”
Ok.

76
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



TrbName





Function Tag for the tributary used by the management system, has no effect on the operation of the


system.




Type Multiple[1-n], where n=1 for 1E1 products, n=2 for 2E1, and n=4 for 4E1



Options ASCII character sequence with a maximum size of 8 elements.



Default -



Application MF4E1, MF2E1, MF1E1, MF4E1/GB, MF2E1/GB, MF1E1/GB



Example 1) Checks the trbname designated for interface number 1:




get trbname[1]↵



trbname[1]=”Digitel”



Ok.



2) Designates the “Port 1” tag to interface 3:




set trbname[3]=”Port 1"↵



trbname[3]=”Port 1"



Ok.










77
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

VEnable

Function Enables the V.35/V.36 interface.


Type Single
Options Yes: interface V enabled
No: interface V enabled
Default No
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example ↵
set venable=yes↵
venable=”yes”
Ok.

78
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



VStatus





Function Read only. Checks the V.35/V.36 serial interface status.



Type Single



Options Ok: normal operation



AIS: AIS detection


Disable: V.35/V.36 interface disabled


Test: local V35 inerface under test commanded locally


RDL: local V35 inerface under test commanded remotely



RDLAck: remote V35 inerface under test commanded locally



Default -



Application MF4E1/GB, MF2E1/GB, MF1E1/GB



Example ↵
get vstatus↵



vstatus=”AIS”



Ok.















79
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Vmode

Function Configures the electrical level of Nx64 serial interface.


Type Single
Options V35: configures V.35 electrical level
V36: configures V.36 electrical level
V28: configures V.28 electrical level
Default V35
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example ↵
set Vmode=V36↵
vmode=”V36"
Ok.

80
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Vck





Function Configures the transmission synchronism source for V.35/V.36 serial interface when in the


unframed mode.




Type Single



Options Int: selects the internal clock


Ext: selects the external clock


Reg: selects the slave clock



Default Int



Application MF4E1/GB, MF2E1/GB, MF1E1/GB



Example ↵
set Vck=Reg↵



vck=”Reg”



Ok.


















81
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Vckinv

Function Inverts the polarity of the transmission clock used in the V.35/V.36 serial interface.
Type Single
Options Yes: inverted polarity
No: normal polarity
Default no
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example ↵
set Vckinv=Yes↵
vckinv=”Yes”
Ok.

82
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Vtest





Function Activation of test loop in the V.35/V.36 serial interface.



Type Single



Options None: normal operation



LDL: local digital loop


RDLSend: sends remote loop activation standard according to standard V.54



Default -



Application MF4E1/GB, MF2E1/GB, MF1E1/GB



Example ↵
set Vtest=ldl↵



vctest=”ldl”



Ok.



















83
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

VCT140EN

Function Enables remote loop activation according to standard V.54, commanded through the V35
electrical interface pin 21 of DB25 connector.
Type Single
Options Yes: enables remote loop command via CT140
No: disables remote loop command via CT140
Default No
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example 1) Enables RDL activation via CT140:

set vct140en=yes↵
vct140en=”yes”
Ok.
2) Checks the configuration of CT140:

get vct140en↵
vct140en=”yes”
Ok.

84
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



VCT141EN





Function Enables local loop activation through the V35 electrical interface pin 18 of DB25 connector.



Type Single



Options Yes: enables remote loop command via CT141



No: disables remote loop command via CT141



Default No



Application MF4E1/GB, MF2E1/GB, MF1E1/GB



Example 1) Enables local Loop activation via CT141:




set vct141en=yes↵



vct141en=”yes”



Ok.



2) Checks the configuration of CT141:




get vct141en↵



vct141en=”yes”



Ok.










85
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

VRDLAccept

Function Enables local loop activation remotely commanded according to standard V.54.
Type Single
Options Yes: enables receival of activation sequence of V.54 loop
No: disables receival of activation sequence of V.54 loop
Default No
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example 1) Enables receival of activation sequence of V.54 loop:

set vrdlaccept=yes↵
vrdlaccept=”yes”
Ok.
2) Checks the configuration of the command:

get vrdlaccept↵
vrdlaccept=”yes”
Ok.

86
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



GStatus





Function Read only. Returns the board synchronism status of framer G.704.



Type Single



Options Ok: normal operation



FrmSyncLos: loss of board synchronism


MFrmSyncLos: loss of multiboard synchronism


RDI: alarm indication in framer G704 of the remote equipment



Default -



Application MF 4E1/GB, MF 2E1/GB, MF 1E1/GB



Example 1) Checks the G.704 link status:




get Gstatus↵



gstatus=”Ok”



Ok.
















87
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Gmode

Function Configures the framer G.704 mode of operation.


Type Single
Options PCM31: configures channels PCM 31
PCM31C: configures channels PCM 31 with CRC
PCM30: configures channels PCM 30
PCM30C: configures channels PCM 30 with CRC
Default PCM 31
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example ↵
set gmode=pcm31↵
gmode=”pcm31"
Ok.

88
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Gck





Function Framer G.704 synchronism source.



Type Single



Options Int: G.704 master clock internally generated



Reg: G.704 master clock synchronized with the 2 Mbps timeslot connected to the framer


Ext1: G.704 master clock synchronized with subchannel 1


Ext2: G.704 master clock synchronized with subchannel 2


Ext3: G.704 master clock synchronized with subchannel 3




Default Int



Application MF4E1/GB, MF2E1/GB, MF1E1/GB



Example ↵
set gck=reg↵



gck=”reg”



Ok.
















89
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Gtss

Function Configures the specified G.704 subchannel initial timeslot.


Type Multiple[1-3]
Options Whole from 1 to 30 or 1 to 31, according to the selected operation mode
Default 1
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example ↵
set gtss[2]=4↵
gtss[2]=”4"
Ok.

90
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Gtsn





Function Configures the number of designated timeslots for the specified G.704 subchannel.



Type Multiple[1-3]



Options Whole from 1 to 30



Default 0



Application MF4E1/GB, MF2E1/GB, MF1E1/GB



Example ↵
set gtsn[3]=10↵



gtss[3]=”10"



Ok.






















91
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

ModEnable

Function Enables the interface that is mounted in a determined expansion slot.


Type Multiple[1-2]
Options Yes: enabled module
No: disabled module
Default No
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example 1) Enables the MOD-1 slot bridge module:

set modenable[1]=yes↵
modenable[1] =”yes”
Ok.

92
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



ModStatus





Function Read only. Returns information about the operation of modules, when installed.



Type Multiple[1-2]



Options The status options vary according to the nature of the module:



1) Bridge module


“BG”


Rt: “10” or “100” or “N/A”


Lk: “UP” or “DOWN”



Auto: “YES” or “NO”


Wan: “Sync” - all the configured WANs care synchronized;


“SyncError” - at least one of the configured WANs is synchronized;



“NotSync” - none of the configured WANs are synchronized;



2) Router module



“RO”


“LOADING” or “OK” or “FAIL” or “DISABLED”




3) E1-G703 module


“G3”


“OK” or “LOS” or “AIS” or “TEST” or “DISABLED”




4) FXO-Voice module


“FO”



“abcd = xxxx” (with x=”0" or “1”)





93
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

5) FXS-Voice module
“FS”
“abcd = xxxx” (with x=”0" or “1”)

Default -
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example ↵
get modstatus[2]↵
modstatus[2]=”BG Rt:100 Lk:UP Auto:YES Wan=Sync”
Ok.


get modstatus[2]↵
modstatus[2]=”FO abcd=0001”
Ok.


get modstatus[2]↵
modstatus[2]=”G3 OK”
Ok.

94
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



ModTest





Function Test loop activation in the selected expansion module interface, when the nature of the


module allows this operation.




Type Multiple[1-2]



Options None: normal operation


LDL: local digital loop



Default None



Application MF4E1/GB, MF2E1/GB, MF1E1/GB



Example ↵
set modtest[1]=ldl↵



modtest[1] =”ldl”



Ok.



















95
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Zin

Function Configures the line interface impedance of FXS and FXO modules.
Type Multiple[1-2]
Options 600: 600 ohms
900: 900 ohms
Default 600
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example ↵
set zin[1]=900↵
zin[1] =”900”
Ok.

96
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



TxGain





Function Configures the line interface transmission gain of FXS and FXO modules.



Type Multiple[1-2]



Options -4, -3, -2, -1, 0, 1, 2, 3, 4



Default 0



Application MF4E1/GB, MF2E1/GB, MF1E1/GB



Example Configures the transmission gain to -1dB:




set txgain[1]=-1↵



txgain[1] =”-1”



Ok.




















97
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

RxGain

Function Configures the line interface receiving gain of FXS and FXO modules.
Type Multiple[1-2]
Options -4, -3, -2, -1, 0, 1, 2, 3, 4
Default 0
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example Configures the receiving gain to +2dB:

set rxgain[1]=+2↵
rxgain[1] =”+2”
Ok.

98
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



RingFreq





Function Configures the ring frequency generated by the FXS modules.



Type Multiple[1-2]



Options 20, 25



Default 0



Application MF4E1/GB, MF2E1/GB, MF1E1/GB



Example Configures the ring frequency to 20 Hz:




set ringfreq[1]=20↵



ringfreq[1] =”20”



Ok.




















99
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

TaxMode

Function Configures the public telephone line billing mode for FXS and FXO modules.
Type Multiple[1-2]
Options Tone12: billing by 12 kHz tones
Tone16: billing by 16 kHz tones
Inv: billing by line polarity inversion
None: no billing
Default None
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example Configures the billing mode to line polarity inversion:

set taxmode[1]=inv↵
taxmode[1] =”inv”
Ok.

100
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



HotLine





Function Configures the hot-line operation by the FXS modules, when an FXS board and a telephone


set are used at each end of the link.




Type Multiple[1-2]



Options no, yes



Default No



Application MF4E1/GB, MF2E1/GB, MF1E1/GB



Example ↵
set hotline[1]=yes↵



hotline[1] =”yes”



Ok.




















101
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Cbit

Function Configures the signalling protocol “c” bit on FXS and FXO modules.
Type Multiple[1-2]
Options 0, 1
Default 0
Application MF4E1/GB, MF2E1/GB, MF1E1/GB
Example ↵
set cbit[1]=1↵
cbit[1] =”1”
Ok.

102
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Dbit





Function Configures the signalling protocol “d” bit on FXS and FXO modules.



Type Multiple[1-2]



Options 0, 1



Default 1



Application MF4E1/GB, MF2E1/GB, MF1E1/GB



Example ↵
set dbit[1]=1↵



dbit[1] =”1”



Ok.






















103
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

EXAMPLES OF CONFIGURATION

Checking modem statuses individually:


>get model
>get swversion

>get agrstatus
>get trbstatus[1-2]
>get almstatus
>get vstatus
>get modstatus[1-2]
>get modstatus[*]

Checking all modem statuses:


>getstat
>getmod (only for cabinet model)

Checking all the modem configurations:


>getconf

In an MF2E1/GB, using Trib-1 and Trib-2 G.703:


>set tslot[1]=trib1
>set tslot[2]=trib2
>set trbenable[1-2]=yes
>apply
>save

104
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○




>set trbtest[1]=yes


>set trbtest[1]=no




In an MF2E1/GB, using Trib-1 G.703 and V.35 at 2.048 Mbps:



>set tslot[1]=trib1


>set tslot[2]=v35 # maps E1 timeslot # 2 directly to V.35/V.36 interface



>set subch[3]=no


>set trbenable[1]=yes


>set trbenable[2]=no



>set venable=yes



>set vmode=v35



>set vckinv=yes





>set vck=int # chooses the transmission clock configuration


>set vck=ext


>set vck=reg



>apply


>save




>set vtest=yes


>set vtest=no




In an MF2E1/GB, using V.35 at 256 kbps:



>set tslot[1]=g704 # maps E1 timeslot # 1 to framer G.704




105
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

>set tslot[2]=none
>set subch[3]=yes

>set trbenable[1]=no
>set trbenable[2]=no
>set venable=yes

>set vmode=v35
>set vckinv=no

>set gck=int # selects synchronism supply for the G.704 master clock
>set vck=int # chooses the V.35 interface transmission clock configuration

>set gck=reg
>set vck=int

>set gck=ext3
>set vck=ext

>set gmode pcm31


>set gtss[3]=1

>set gtsn[3]=1 # => 64 k


>set gtsn[3]=2 # => 128 k
>set gtsn[3]=4 # => 256 kbps
>apply
>save

106
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○




>set vtest=yes


>set vtest=no





In an MF2E1/GB, using the bridge module at 2.048 Mbps, when the bridge module is mounted in slot MOD1:



>set tslot[1]=mod1 # maps E1 timeslot # 1 to module 1 channel 1


>set tslot[2]=none



>set subch[1]=no



>set trbenable[1]=no



>set trbenable[2]=no


>set venable=no




>set modenable[1]=yes


>save




To extend an Ethernet network with a 2.048 Mbps 4 WAN band, one local and one remote MF4E1/GB, both using the bridge


module (BG) mounted in slot MOD1.



Programming for both modems:



>set tslot[1]=mod1



>set tslot[2]=mod1


>set tslot[3]=mod1


>set tslot[4]=mod1




>set subch[1]=no





107
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

>set modenable[1]=yes
>set venable=no
>set trbenable[1]=no
>set trbenable[2]=no

>save

To interconnect two Ethernet networks with a 2.048 Mbps 1 WAN band, one local and one remote MF1E1/GB, both using
the router module (RO) mounted in slot MOD1.
Programming for both modems:
>set tslot[1]=mod1
>set subch[1]=no

>set modenable[1]=yes
>set venable=no
>set trbenable[1]=no

>save

To interconnect two Ethernet networks with a 128 Mbps 1 WAN band, one local and one remote MF2E1/GB, both using the
router module (RO) mounted in slot MOD2.
Programming for both modems:
>set tslot[1]=G704
>set subch[2]=yes

108
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○




>set modenable[2]=yes


>set venable=no


>set trbenable[1]=no



>set trbenable[2]=no



>set gmode=pcm31



>set gtss[2]=1


>set gtsn[2]=2 # 128 kbps




>save




Local modem:



>set gck=int # selects synchronism supply for the G.704 master clock


>save




Remote modem:



# selects synchronism supply for the G.704 master clock


>set gck=reg


>save




To transport four E1-G.703 channels, one local and one remote MF4E1/GB, both using the tributaries and two mounted


G.703 (G3) modules:



Programming for both modems:




>set tslot[1]=trib1


>set tslot[2]=trib2


>set tslot[3]=mod1



109
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

>set tslot[4]=mod2

>set subch[1]=no
>set subch[2]=no
>set trbenable[1]=yes
>set trbenable[2]=yes
>set modenable[1]=yes
>set modenable[2]=yes
>save

>set trbtest[1]=ldl
>set trbtest[1]=no
>set modtest[1]=ldl
>set modtest[1]=no
>get trbstatus[1]
>get modstatus[1]

To extend a telephone line or a local PABX telephone extension to a remote point, one local MF2E1/GB using one FXO (FO)
voice module, and one remote MF2E1/GB using one FXS (FS) voice module:
Local modem, FXO in slot MOD1:
>set tslot[1]=G704
>set subch[1]=yes
>set modenable[1]=yes

110
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



# selects synchronism supply for the G.704 master clock


>set gck=reg


>set gmode=pcm30


>set gtss[1]=1


# 64 kbps


>set gtsn[1]=1



>set taxmode[1]=none #for residential telephone set


#for public telephone


>set taxmode[1]=inv



>set zin[1]=600



>set hotline[1]=no



>save




Remote modem, FXS in slot MOD2:




>set tslot[1]=G704


>set subch[2]=yes


>set modenable[2]=yes


>set gck=int # selects synchronism supply for the G.704 master clock



>set gmode=pcm30


>set gtss[2]=1


>set gtsn[2]=1 # 64 kbps




>set taxmode[2]=none #for residential telephone set


>set zin[2]=600




>set taxmode[2]=tone12 #for public telephone


>set zin[2]=900




111
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

>set hotline[2]=no

>save

To connect a telephone set to each side (hot-line), one local and one remote MF2E1/GB, both using one FXS (FS) voice
module and mounted in slot MOD1:
Programming for both modems:
>set tslot[1]=G704
>set subch[1]=yes
>set modenable[1]=yes

>set gmode=pcm30
>set gtss[1]=1
>set gtsn[1]=1 # 64 kbps
>set taxmode[1]=none
>set zin[1]=600
>set hotline[1]=yes

>save

Local modem:
>set gck=int # selects synchronism supply for the G.704 master clock
>save

112
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Remote modem:



# selects synchronism supply for the G.704 master clock


>set gck=reg



>save



Loop with a 2.048 Mbps 3 WAN Ethernet network and one telephone extension, one local MF4E1/GB using the bridge


module (BG) mounted in slot MOD1 and one FXO (FO) module in MOD2, and one remote MF4E1/GB using the bridge module


(BG) mounted in slot MOD1 and one FXS (FS) module in MOD2:



Programming for both modems:



>set tslot[1]=mod1



>set tslot[2]=mod1


>set tslot[3]=mod1


>set tslot[4]=G704




>set subch[1]=no


>set subch[2]=yes




>set modenable[1]=yes


>set modenable[2]=yes




>set gmode=pcm30


>set gtss[2]=1


# 64 kbps


>set gtsn[2]=1



>set taxmode[1]=none



>set zin[2]=600





113
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

>set hotline[2]=no

>save

Local modem:
>set gck=int
>save

Remote modem:
>set gck=reg
>save

Loop with interconnection of two 1.856 Mbps 1 WAN Ethernet networks and one telephone extension, one local MF1E1/GB
using the router module (RO) mounted in slot MOD1 and one FXO (FO) module in MOD2, and one remote MF1E1/GB using the
router module (RO) mounted in slot MOD1 and one FXS (FS) module in MOD2:
Programming for both modems:
>set tslot[1]=G704

>set subch[1]=yes
>set subch[2]=yes

>set modenable[1]=yes
>set modenable[2]=yes

>set gmode=pcm30

114
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○




>set gtss[1]=2


>set gtsn[1]=29 # 1856 kbps


>set gtss[2]=1


# 64 kbps


>set gtsn[2]=1



>set taxmode[1]=none



>set zin[2]=600


>set hotline[2]=no




>save




Local modem:



>set gck=int


>save




Remote modem:




>set gck=reg


>save














115
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

SOFTWARE UPDATE VIA CONSOLE PORT

Software updating is performed through the existing console port in the front panel of cabinet model modems, and
through an auxiliary console available in connector P3 of the subrack model modems board.
Console port in the cabinet model
DB9 connector pinout

Pin Function

1 DCD
2 RD
3 TD
4 -
5 GND
6 DSR
7 RTS
8 CTS
9 -

116
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



Console port in the subrack model



P3 connector pinout




Pin Function



1 GND



2 CTS



3 TD



4 RTS



5 RD



6 DCD





To update the software, the following must be available:



• update software: LoaderDigitel.exe;



• update file: versionxxxx.DWN;



• PC microcomputer with Windows operational system;



• cable 1:1 for connection between the conselo and the PC serial port;



• auxiliary console adapter cable in the case of subrack model modem.




ATTENTION!


Updating of a product with software for another product is blocked through a key word used in the updating file.





117
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

The procedure to be followed to update software is described below.


1. Connect the console to the serial port of a PC microcomputer.
2. Place dip-switch key in the UP position.
3. Turn the modem off and on again.
4. At the PC, execute/open the LoaderDigitel.exe program.
5. Configure the program as follows:
• port COM1 or COM2;
• modem model: “METROFIBER CENTRAL” or “METROFIBER CABINET”;
• file to update: versãoxxxx.DWN.
6. Click the Start button.
7. At the end of the update, the program will inform whether it was successful. If there are any problems, restart the process from
step 2.
8. Place key 1 in the DOWN position.
9. Turn the modem off and on again.
Through the get SwVersion command it is possible to view the software version being used by the modem.
The software updating process for the Metrofiber line modems is highly secure. For example, if you experience any
problems during the updating process, such as a power cut or disconnected cable, the modem can restart the updating process
or resume normal operation, since it retains the previous software version.
This updating process takes approximately 15 minutes.

118
Configuration/operation
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



SOFTWARE UPDATE VIA MANAGEMENT SYSTEM





When using a METRO line equipment network comprising a central point of an MF/SUB subrack and an MF/SMNP


management board it is possible to update modem and data converter software in this network through the management board.



The latest software version for the MF/SNMP management board features the latest software versions of the METRO line


elements managed by it.



It is possible to command the update directly from the DMS Digitel management system by means of either a graphic



interface or through commands on the MF/SNMP board console port.



During update with this process, data transport at all boards continues to operate normally, including at the board being


updated. At the end of the software update, the modem board will be restarted with a momentary interruption of data traffic.


Management, configuration and monitoring of the other network boards also continue to operate, except for the board being



updated. This updating process takes approximately 50 minutes for each board.



For updating via DMS, please refer to the electronic documentation included with the software.



For updating the MF/SNMP board via console, use the "update[slot]" command, where "slot" is the number of the slot


where the modem of converter is inserted on the subrack, varying from 1 to 20. To update the remote modems the slot value


varies from 21 to 40, respectively. An update queue may be programmed, for example: "update[2;5;7-9]", the slot2, slot5, slot7,



slot8 and slot9 modem will be updated. For further details about operation of this board, please refer to the MF/SNMP board


manual.













119
• Applications
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

The Metrofiber line was designed for use in point to point applications and operates in a central (subrack/closet) from
where the optical fibers are distributed to several users. The figure below illustrates this situation.

The cabinet modems feature a large variety of electrical interfaces and optional modules, and offers the following services:
• G.703 interfaces at 2.048 Mbps, 75 or 120 ohms;
• V.35 or V.36 interface with speeds of 64 kbps to 2.048 Mbps in 64 kbps steps, with several synchronism source
options;
• Ethernte interface with a remote bridge, with one to four 2.048 Mbps WANs or one 64 kbps WAN at 2.048 Mbps;
• Ethernet interface with a remote router and one 64 kbps WAN at 2.048 Mbps;
• interface with one FXS voice channel;
• interface with one FXO voice channel;
It is also possible to operate directly between two cabinet models, as shown in the following figure.

120
Applications
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○











As to the installation, the Metrofiber line is very versatile, allowing for the installation of up to 20 modem boards in a 19”, 3



UR height subrack of reduced depth. All connections are at the front, an ideal characteristic for closets of reduced dimensions.



The use of connection panels allows for the assembly of connectors facing the front or rear of the 19” rack. Also, this type of


panel allows easy access to the connectors and is insulated from the modem boards, avoiding problems of handling by third parties.



By using this system, with a single subrack and connections panels, it is possible to transport up to 80 E1 channels for up


to 20 clients.



The cabinet model allows for desk, wall and 19” rack assembly through side adaptors.



The optical interfaces are tilted in relation to the front panel, which reduces the risk of damaging the connected optical fiber cables.



By using two G.703 (G3) expansion modules in an MF4E1 cabinet model modem, it is possible to transport up to four E1



channels of transparent 2.048 Mbps.



By using the Router (RO) module in a cabinet model modem, it is possible to transport one Ethernet channel, which allows


the interconnection of different networks with one data band provided by one WAN channel between 64 kbps and 2.048 Mbps.


This WAN can be connected either to a framer G.704 or directly to the optical channel. This allows for either the interconnection of



different networks or internet access.



By using the Bridge (BG) module in a cabinet model modem, it is possible to transport one Ethernet channel to extend the


same network, with one data band provided by one WAN channel between 64 kbps and 2.048 Mbps or by up to four 2.048 Mbps


channels, in the case of an MF4E1. This WAN can be connected either to a framer G.704 or the 4 WANs, directly to the optical



channel. This allows the interconnection of two segments in the same Ethernet network to extend, for example, a corporate


network from the main office to its branches.



121
Applications
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

By using a voice channel module in a cabinet model modem, it is possible to transport one telephone channel with all its
signalling and at the same time data from another application in another electrical interface. The FXO module allows the connection
to either the public telephone network or a PABX extension. The FXS module allows the connection with either standard telephone
sets of public telephones. This way, it is possible to perform the extension of a PABX extension with one FXO in a point of the loop
and with one FXS to another point, where a telephone set is connected. It is also possible to use the hot-line mode.
The hot-line mode allows the connection of two telephone sets at each point of the loop. for such, there must be a cabinet model
modem at each point of the loop with one FXS module installed. When the single phone is removed from the hook on one side, a call is made
to the other side through a ring signal. Someone just needs to answer at the other end to start a conversation.
Detailed configuration of some of these modes is described in the Examples of configuration section in this manual.
The use of a Bridge ou Router module together with a voice module allows for an ideal solution to extend the infrastructure
of a main office to a branch by transporting, at the same time, the Ethernet network and telephone access, being either a central
PABX extension or a hot-line. In case interconnection of a large sized branch to several extensions is required, it is also possible
to use the module G.703 tributaries to transport E1 channels with up to 30 timeslots to connect to another PABX. In case the
extension of a data channel of some proprietary system is also required, the V.35/V.36 interface, as well as the G.703 tributary
interface, remain available.
In case the branch is very distant, it is possible to establish an optical link with a cabinet model modem at the main office
and a board model modem mounted in a subrack at a telephone operator, where the E1 channels enter the PDH network. Once
this is done, it is possible to extract those channels at another point of the country and establish another optical link to the branch,
where there is another cabinet model modem with the adequate interface converter modules.
The configurations and monitoring of the cabinet model modems installed at the remote point that communicate with the
board model modems installed in a subrack can be performed through the management board using their serial console, telnet,
SNMP commands or the DMS management system developed by Digitel.

122
• Specifications
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



SUBRACK MODEL





MF4E1, MF2E1 and MF1E1 modems



Technology PDH


Speed 68.783 Mbps with proprietary encoding in the optical aggregate interface


2.048 Mbps at the G.703 tributary interfaces



Connection modes Point to point


Electrical interfaces MF1E1: one E1 G.703 interface (120 or 75 ohms), RJ45 and BNC connector



MF1E1: one E1 G.703 interface (120 or 75 ohms), RJ45 and IEC connector


MF2E1: two E1 G.703 interfaces (120 or 75 ohms), HD26 connector


MF4E1: four E1 G.703 interfaces (120 or 75 ohms), HD26 connector



Optical interfaces SAM3: single fiber, 1310 nm, SC/APC connector


EM3: single fiber, 1310 nm, E2000 connector


SP3: pair of fibers, 1310 nm, SC/PC, SC/UPC or SC/APC connector



SP3M: multimode pair of fibers, 1310 nm, SC/PC, SC/UPC or SC/APC connector


SP5: pair of fibers, 1550 nm, SC/PC, SC/UPC or SC/APC connector


FCP3: pair of fibers, 1310 nm, FC connector



SC35: single fiber, emitter: 1310 nm, receiver: 1550 nm, SC/PC, SC/UPC or SC/APC connector


SC53: single fiber, emitter: 1550 nm, receiver: 1310 nm, SC/PC, SC/UPC or SC/APC connector



FC5D: pair of fibers, 1550 nm-DFB, FC connector


Configuration/ Via subrack management board


Management



Testing facilities Local: LDL at the E1 G.703 interfaces via key located at the front panel


Local: LDL at the E1 G.703 interfaces via management board



Remote: LDL at the E1 G.703 interfaces via management board


Dimensions 13.2 cm x 19.7 cm x 1.8 cm


Approximate weight 0.18 kg



123
Specifications
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

MF4E1, MF2E1 and MF1E1 modems

Consumption MF1E1: 3 W
MF2E1: 3.1 W
MF4E1: 3.7 W
Standards Telebrás Practice 225-600-703
ITU-T G.703
ITU-T G0.742
ITU-T G0.751
ITU-T G0.823

Connection panels

MF/PPBNC Adapter for two MF2E1 or MF4E1 modems, HD26 for BNC
MF/PPIEC Adapter for two MF2E1 or MF4E1 modems, HD26 for IEC
MF/PPRJ Adapter for two MF2E1 or MF4E1 modems, HD26 for RJ45
Dimensions 48 cm x 3.3 cm x 3 cm
Approximate weight 0.5 kg

124
Specifications
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○




Management module



Alarms One dry contact output and two dry contact inputs



Management One 10/100 Mbps Ethernet port



interfaces One serial port for console



Management module




Consumption 5W



Dimensions 13.2 cm x 19.7 cm x 1.8 cm



Approximate weight 0.1 kg





Supply for 19” subrack




Operating voltage MF/AC: 93-253 VAC


MF/DC: 36-60 VDC



Dimensions 20.5 cm x 12.9 cm x 5.3 cm



Approximate weight 0.9 kg












125
Specifications
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

19” subrack

Capacity Without redundancy: one power supply, one management board, 20 modems
With redundancy: two power supplies, one management board, 17 modems
Dimensions 20.4 cm x 13.2 cm x 48 cm
Approximate weight 2.7 kg

Environmental conditions

Operation 0 to 65 °C
Storage -5 to 65 °C
Transport -40 to 70 °C
Relative Humidity up to 90%

126
Specifications
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○



CABINET MODEL





MF4E1, MF2E1 and MF1E1 modems



Technology PDH



Speed 68.783 Mbps with proprietary encoding in the optical aggregate interface


2.048 Mbps at the G.703 tributary interfaces 64 kbps at 2,048 Mbps in the V.35/V.36 interface,


in Nx64 kbps step, according to G.704



Connection modes Point to point



Optical interfaces SAM3: single fiber, 1310 nm, SC/APC connector


EM3: single fiber, 1310 nm, E2000 connector



SP3: pair of fibers, 1310 nm, SC/PC, SC/UPC or SC/APC connector


SP3M: multimode pair of fibers, 1310 nm, SC/PC, SC/UPC or SC/APC connector


SP5: pair of fibers, 1550 nm, SC/PC, SC/UPC or SC/APC connector



FCP3: pair of fibers, 1310 nm, FC connector


FC5D: pair of fibers, 1550 nm-DFB, FC connector


SC35: single fiber, emitter: 1310 nm, receiver: 1550 nm, SC/PC, SC/UPC or SC/APC connector



SC53: single fiber, emitter: 1550 nm, receiver: 1310 nm, SC/PC, SC/UPC or SC/APC connector



Electrical interfaces MF1E1: one E1 G.703 interface (120 or 75 ohms), RJ45 and BNC or IEC connector; one V.35 or


V.36 interface, DB25 connector, ISO-2110 standard


contiMF2E1: two E1 G.703 interfaces (120 or 75 ohms), RJ45 and BNC or IEC connector; one V.35



or V.36 interface, DB25 connector, ISO-2110 standard


MF4E1: two E1 G.703 interfaces (120 or 75 ohms), RJ45 and BNC or IEC connector; one V.35 or


V.36 interface, DB25 connector, ISO-2110 standard



# of timeslots MF1E1: one 2.048 Mbps channel



available in the aggregate MF2E1: two 2.048 Mbps channels MF4E1: four 2.048 Mbps channels



127
Specifications
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

MF4E1, MF2E1 and MF1E1 modems

Configuration/ Via dips located in the front panel


Management Via console port located in the front panel
Via subrack management board of the subrack model
Testing facilities Local: LDL at the E1 G.703 and V.35 interfaces via key located at the front panel
LOCAL: LDL at the E1 G.703 interfaces via console
REMOTE: LDL at the E1 G.703 interfaces via console
REMOTE: RDL in the V35 interface according to V.54, via console.
REMOTE: RDL in the V35 interface according to V.54, via interface pins.
Operating facilities Cross-connect between timeslots and electrical interfaces
Optional modules BG: bridge
RO: router
G3: G.703 at 2.048 Mbps.
FO: FXO voice
FS: FXS voice
Operating voltage AC 127/220: 93-253 VAC
DC 48: 36-60 VDC
DC 24: 20-30 VDC
AD 48/127/220: 36-60 VDC or 93-253 VAC
Consumption MF1E1: 3.4 W
MF2E1: 3.9 W
MF4E1: 3.9 W
Installation Desk, 19” subrack or wall Operating temperature 0 to 65°C

128
Specifications
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○




MF4E1, MF2E1 and MF1E1 modems



Dimensions 16.7 cm x 4.4 cm x 22.4 cm



Approximate weight 1.5 kg



Standards Telebrás Practice 225-600-703



ITU-T G.703 ITU-T G0.742


ITU-T G0.751 ITU-T G0.823


ITU-T G0.704 ITU-T V.24



ITU-T G0.28 ITU-T G.V.35


ITU-T G.V.36






Bridge Module (BG)



Interface 10/100 Base-T Ethernet, female RJ45 connector



Packet sizes Maximum size: 1522 bytes, with VLAN support



WANs one to four 2.048 WANs (the first is configurable from 64 kbps to 2.048 Mbps)



MAC address table Storage capacity of up to 1024 source MAC addresses, for filtering



Memory buffer Capacity of 576 packets with 1522 bytes




Consumption 2W



Standards ANSI/IEEE Std 802.3 CSMA/CD LAN (Ethernet)


ANSI/IEEE Std 802.1 (Bridge)


ANSI/IEEE 802.1q (VLAN)




129
Specifications
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Router Module (RO)

Interface 10/100 Base-T Ethernet, female RJ45 connector


WANs One 64 kbps to 2.048 Mbps WAN
Consumption 1.7 W
Protocols PPP, PPP-HDLC, PPP-IPCP, FRAME RELAY, SNMP-TRAPS, MIB-II, IP-CMPRS, Bridge, TFTP, PAP,
CHAP, NAT, SNMP, SMI, RIP, FTP, IP-E, ARP, TCP, ICMP, IP, UDP, OSPF, RIPII, TELNET, DNS, VRRP
Standards ANSI/IEEE Std 802.3 CSMA/CD LAN (Ethernet)
ISO/IEC 8802-3 CSMA/CD LAN (Ethernet)

G703 module (G3)

Interface G.703, 2.048 Mbps (75 and 120 ohms)


Connectors: BNC or IEC for 75-ohm interface
RJ45 for 120-ohm interface
Consumption 0.3 W
Standards ITU-T G.703

130
• Purchasing information
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○




FXO (FO) voice interface module



Interface One FXO type voice interface



Connector RJ11 to connect to the telephone network



Features Current retention and ring detection



Programmable transmission and receiving gains between -4dB and +4dB


Telephone signalling according to TELEBRAS 220-550-704 practice



Consumption 0.9 W



Standards TELEBRÁS Practice 220-550-704





FXS (FS) voice interface module




Interface One FXS type voice interface



Connector RJ11 to connect to a standard telephone set



Features Support for public telephone


Battery voltage and ring signal generator


Programmable transmission and receiving gains between -4dB and +4dB



Telephone signalling according to TELEBRAS 220-550-704 practice



Consumption 2.8 W



Standards TELEBRÁS Practice 220-550-704







131
Purchasing information
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

MF*/1/2/3/4/5/ (modem model code)


Where:
* Transport capacity specification:
1E1P transport in the 1E1 fiber, board model
2E1P transport in the 2E1 fiber, board model
4E1P transport in the 4E1 fiber, board model
1E1G transport in the 1E1 fiber, cabinet model
2E1G transport in the 2E1 fiber, cabinet model
4E1G transport in the 4E1 fiber, cabinet model
1 Optical interface specification:
SP3 SC/pair of fibers/1310
SAM3 SC/APC/single fiber/1310
SP3M SC/multimode fiber pair, 1310
EM3 E2000/single fiber/1310
SP5 SC/pair of fibers/1550
FCP3 FC/pair of fibers/1310
FC5D FC/pair of fibers/1550-DFB
SC35 SC/single fiber/Tx1310nm, Rx1550nm
SC53 SC/single fiber/Tx1550nm, Rx1310nm
2 Electrical interface specification (field valid only for models 1E1P, 1E1G, 2E1G and 4E1G):
I IEC type connectors
B BNC type connectors
3 Interface 1 module specification (field valid only for models 1E1G, 2E1G and 4E1G):
FS FXS type voice interface
FO FXO type voice interface

132
Purchasing information
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○




MF*/1/2/3/4/5/ (modem model code)



RO 10/100 Mbps Ethernet interface with router function


BG 10/100 Mbps Ethernet interface with remote bridge function


G3 G.703 interface at 2.048 Mbps (75/120 ohms)



X without interface module


4 Interface 2 module specification (field valid only for models 1E1G, 2E1G and 4E1G):



FS FXS type voice interface


FO FXO type voice interface


RO 10/100 Mbps Ethernet interface with router function



BG 10/100 Mbps Ethernet interface with remote bridge function


G3 G.703 interface at 2.048 Mbps (75/120 ohms)


X without interface module



5 Power supply specification (field valid only for models 1E1G, 2E1G and 4E1G):


AC AC power supply



DC DC power supply


AD AC or DC power supply



800.0941.00-5 M/SUB METRO line 19" subrack


800.0942.00-1 PP/BNC BNC type connector panel for 19" subrack


800.0943.00-8 PP/IEC IEC type connector panel for 19" subrack



800.0944.00-4 PP/RJ RJ45 type connector panel for 19" subrack


800.0945.00-0 M/AC AC power supply module for 19" subrack


800.0946.00-7 M/DC DC power supply module for 19" subrack



800.0951.00-0 M/SNMP Management module for 19" subrack


810.0356.00-7 CB-C/4E1/75 Cable for PP/BNC or PP/IEC, MF4E1P or MF2E1P


810.0357.00-3 CB-C/2E1/75 Cable for PP/BNC or PP/IEC, MF2E1P


810.0358.00-0 CB-C/4E1/120 Cable for PP/RJ, MF4E1P or MF2E1P



810.0359.00-6 CB-C/2E1/120 Cable for PP/RJ, MF2E1P



133
• Warranty and technical support
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

During the period covered by this warranty (specified in your invoice), Digitel bears responsibility for the proper functioning of your
equipment, in accordance with the characteristics and specifications described in the product installation and operation manual. If you
detect a problem, contact our Technical Support Center and describe the defect you have detected.

This warranty covers repair and substitution of parts and components at no cost for the customer when carried out by Digitel Technical
Support Centers. This warranty does not cover defects resulting from other equipment connections to this product or improper use
of the equipment inasmuch as the instructions in this manual are not properly followed or the repairs performed at shops other than
those accredited by Digitel.

This warranty does not cover field repairs. Digitel will NOT pay charges incurred for returning the equipment to the customer.

DIGITEL S.A. INDÚSTRIA ELETRÔNICA


Rua Dr. João Inácio, 1165 – Bairro: Navegantes
CEP 90230-181 – Porto Alegre/RS Brasil
Tel: 55 51 3337.1999 – Fax: 55 51 3337.1923
CNPJ: 89.547.269/0001-04 – Inscrição Estadual: 0960602577
http://www.digitel.com.br – E-mail: info@digitel.com.br

134
2009 - DIGITEL S.A. INDÚSTRIA ELETRÔNICA
Rua Dr. João Inácio, 1165
Bairro: Navegantes
CEP 90230-181 • Porto Alegre/RS • Brasil
Tel: 55 51 3337.1999
Fax: 55 51 3337.1923
http://www.digitel.com.br
E-mail: info@digitel.com.br

Potrebbero piacerti anche