Sei sulla pagina 1di 6

BULLETIN 381D

Sethco
MODEL P90
P 90
DRUM PUMP
SEALLESS
DRUM PUMPS
FOR SAFE AND FAST
TRANSFER OF
CHEMICALS • SOLVENTS
• CORROSIVE LIQUIDS IN
HAZARDOUS OR
NON HAZARDOUS
ENVIRONMENTS

In Use The World Over


• SEALLESS
• EMPTIES 55 GALLON DRUMS IN LESS
THAN 2 MINUTES
• SELF PRIMING
• HIGH POWER DOUBLE INSULATED
1150 WATT MOTOR
• EASY MAINTENANCE, FIELD
REPAIRABLE
• ONE PIECE TUBE INSURES SAFE,
LEAKPROOF OPERATION
• CHOICE OF POLYPROPYLENE,
KYNAR®, OR STAINLESS STEEL
PUMPS

Sethco Division
SETHCO MODEL P-90 DRUM PUMPS
THE RIGHT CHOICE FOR TRANSFERRING CORROSIVE LIQUIDS FROM CARBOYS, DRUMS, VATS, TANKS OR ANY OTHER CONTAINER

Pump Tube Features: Motor Features:

• Polypropylene, Kynar or • High power, double


stainless steel pump construction insulated 1150 watt motor
Choose from 3 materials of construction to Protected in a corrosion resistant,
transfer most corrosive liquids. high-strength, impact resistant case.

• Sealless construction • Large handle grip


Eliminates the major cause of pump failure. Ensures grasp when wearing bulky
safety rubber gloves.
• Can run dry
No costly damage to pump if it is run • Impact resistant housing
dry for short periods after drum or Holds up to rough handling.
container has been emptied.
• 15 foot cord
• 1.66” (42mm) tube diameter Motor is equipped with a heavy duty
Designed to fit any bung to empty oil and acid resistant electrical
any drum or carboy around the cord and molded plug.
world.
• On/Off switch with
• More effective vapor seal safety reset circuit
breaker
• High quality design Unlike hazardous automatic
One piece tube construction, fewer restart units, the motor will
pump parts and new bearing cup not restart until on/off switch
ensure reliability and extends resets the circuit breaker.
pump life. New P90 pump tube is Momentary switches are
lighter and stronger than the available.
P80 pump tube.
• Continuous duty
• Self priming rated
A flip of the switch and pumping The powerful electric motor
action begins immediately. will pump liquids continuously
drum after drum without
overloading the motor, even
• Quick draining when pumping high specific
Pump drains quickly when
gravity solutions.
removed from liquid.

• Hazardous duty
• Wide vane axial impeller and air motor also
Efficiently moves high viscosity and
specific gravity liquids up to available
4000 ssu. For safe transfer of
hazardous, flammable
or combustible liquids.
• High flow
Empties a 55 gallon drum in less
than 2 minutes. Empties a 500 • Lightweight
gallon tank in less than 13 minutes. Weighs only 9 pounds.

• Easy to maintain
New bearing cup design allows fast,
inexpensive, easy to do repairs.
No special tools needed.
SELECT FROM 3 HIGH POWER INTERCHANGEABLE MOTORS
High-Power Double Insulated Hazardous Duty Electric Motor Hazardous Duty Air Motor
1150 Watt Motor UL Listed, 650 watt motor is specifically Can be used in place of electric motor
Lightweight, impact resistant and easy designed to be used with the Sethco when desired. Completely interchange-
to handle, this motor is the most widely stainless steel P90 pump to safely trans- able on any P90 pump. Recommended
used. Select this motor when transfer- fer hazardous flammable or combustible for use in areas where flammable
ring liquids that are non-hazardous. Can liquids. Can also be used with Sethco vapors or other hazardous duty condi-
be used with any P90 pump tube. Kynar P90 pump to transfer non- tions exist.
flammable chemicals in a hazardous
environment.

30”, 40”
50” and 60”
Standard
Pump Tube
Lengths

6 MONTH
WARRANTY!
Twice the length
of most other
drum pumps

...AND 3 INTERCHANGEABLE PUMP TUBE ASSEMBLIES


POLYPROPYLENE STAINLESS STEEL KYNAR®
Economical and Dependable Heavy Duty design for Superior corrosion resistance,
Wetted Parts extended life withstands higher temperature.
Polypropylene, Hastelloy C®, Tefzel®, Wetted Parts Wetted Parts
Viton®. Stainless Steel, Teflon®, Kynar®. Kynar®, Hastelloy C, Tefzel®, Viton®.
Typical Applications Typical Applications Typical Applications
Hydrochloric acid, sulfuric acid, nitric Alkalies, aqueous caustic, light oils, and Strong mineral and oxidizing acids, alka-
acid, most electroplating solutions solvents. lies, metal etchants, chlorine,
sodium hydroxide, alkaline solutions, Temperature Limits aqueous caustic, organic and non-
chromic acid and other non flammable 0° to 250°F (-18° to 121°C) flammable solvents.
solutions. Temperature Limits
Temperature Limits 0° to 250° F (-18° to 121°C)
32° to 130°F (0° to 55°C)
THE P-90 DRUM PUMP PROVIDES HIGH VOLUME PUMPING TO 35 GPM (132 LPM)
Flow curve for Polypropylene or Kynar Pump Tube with standard Flow curve for Stainless Steel Pump Tube with electric motor, air
1150 watt electric motor, air motor or hazardous duty motor. motor and hazardous duty electric motor.
M. FT M. FT
45 45

40 40
12 12
35 EL 35
EC
10 TR 10
30 IC 30 HA
/H ZA
AZ RD
8 AR 8 OU
25 25 S
DO DU
U S TY
6 20 DU 6 20 M
TY OT
O
AI R
15 15 AI
M

R 4 R
O

4 MO
TO

TO MO
10 TO
R

10 R R
2 2 5
5

0 0

5 10 15 20 25 30 35 40 45 GPM 5 10 15 20 25 30 35 40 45 GPM

0 20 40 60 80 100 120 140 160 LPM 0 20 40 60 80 100 120 140 160 LPM

TEST FLUID — WATER AT 70°F (21°C) TEST FLUID — WATER AT 70°F (21°C)

ACCESSORIES

Flow
Totalizer
Accuately
measures the
flow of liquid.
NEW!
No more
guessing.
Easy to
install and
runs on
2 AAA
batteries. Hand Flow Regulator Vinyl Hose
Safe, leakproof, automatic flow Clear, pliable, corrosion
control. The “easy squeeze” resistant. For use with most
hand lever permits controlled acids and alkalies and water
flow of corrosive liquids. Sethco base solutions. 10 ft. of vinyl
hand flow regulators are hose is supplied with each
optional and available in complete polypropylene P90
polypropylene, aluminum or pump and motor.
stainless steel construction.

Bottom Inlet Strainer Storage Hook Bung Adapter Bonding Wire


Fits over pump tube to prevent Allows the pump to be safely Holds pump tube securely in the Required when pumping
debris from entering pump. stored in an upright position bung opening (optional). flammables to bond and ground
Stainless steel pump tube has out of the way, and insures equipment.
built in strainer. (Supplied with complete drainage after use.
each complete P90 pump and (Supplied with each complete
motor). P90 pump and motor).
Pump and Motor Specifications

PUMP TUBES
Tube Maximum Shipping
Maximum
Diameter Flow Maximum Specific Maximum Net Weight
Tube
Length* Wetted (at widest point) Discharge (water at Head Gravity** Viscosity** Weight w/o Hose
MODEL (in / cm) Materials (in / cm) (in / cm) 70°F / 21°C) Gravity** (reduced flow and pressure) (lbs. / kg) (lbs. / kg)

POLYPROPYLENE PUMP TUBE


P90H-30 30 / 76 Polypropylene, 1.75 / .80 5 / 2.3
P90H-40 40 / 101 Tefzel®†, for 1” I.D. 35 GPM / 39 ft. / 4000 SSU 2.75 / 2 5.5 / 2.5
1-2/3” / 4.2 cm 1.86
P90H-50 50 / 127 Hastelloy C®, Hose 132 LPM 1189 cm (850 cks) 2.75 / 1.25 6 / 2.7
P90H-60 60 / 152 Viton® 3.25 / 1.5 6.5 / 2.9

PVDF PUMP TUBE


P90H-30K 30 / 76 PVDF 2.75 / 1.25 5 / 2.3
P90H-40K 40 / 101 Tefzel®†, for 1” I.D. 35 GPM / 39 ft. / 4000 SSU 3.25 / 1.5 6.5 / 2.9
1-2/3” / 4.2 cm 1.86
P90H-50K 50 / 127 Hastelloy C®, Hose 132 LPM 11.5 m (850 cks) 3.75 / 1.7 6 / 2.7
P90H-60K 60 / 152 Viton® 4.25 / 1.9 7.5 / 3.4

STAINLESS STEEL PUMP TUBE


SS-316, Both 3/4”
Carp. 20, 35 GPM / 40 ft. / 4000 SSU
(1.9 cm) FNPT
P90S-40S 40 / 101 1-3/4” / 4.4 cm 132 LPM 11.5 m 1.86 (850 cks) 8 / 3.6 11.5 / 5.2
PVDF & 1-1/4” ID
Hose
Teflon®

* For other lengths consult factory


** With electric motor drive
† Available with Nylon in place of Teflon for nuclear service.

MOTORS

Net Weight Shipping Weight


Motor Description (lbs. / kg.) lbs. / kg.)

Air Drive-100 PSI @ 18 CFM


A With inlet air valve for motor speed and flow control, and 2 lbs. / .9 kg. 5 lbs. / 2.2 kg.
muffler for quiet operation

Electric - 115V, 50/60Hz, 1 ph, ODP, double-insulated with


15 feet of line cord, plug and on/off switch with built-in safety
B 7 lbs. / 3.2 kg. 9 lbs. / 4 kg.
manual reset circuit breaker. Motor cannot accidentally restart after
breaker trips. Switch must be manually turned back on to reset breaker.

Electric - 230V, 50/60Hz, 1 ph. ODP, as per “B” above.


C 7 lbs. / 3.2 kg. 9 lbs. / 4 kg.
Plug is not provided.

Electric-Hazardous Duty U.L. Listed “Portable” Class 1, Groups C


E and D, 120V, 60Hz., 1 ph, with built-in-switch, and internal thermal 19.5 lbs. / 8.8 kg. 21.5 lbs. / 9.7 kg.
overload, 15 feet of 3-wire grounded cord and easy carry handle.

WARRANTY
180 day warranty against defective parts and workmanship. The standard warranty does not apply when equipment is used contrary to
factory recommendations.
Since the policy of Sethco is one of continual improvement, we reserve the right to change design or materials at any time without giving notice
or creating any obligation to previous or future customers.
We asked our customers how they use their Sethco
drum pump and this is what some of them said....


Electronics & Printed Circuits Industrial Cleaners
• Pumping acids at 70° to 130°F for • Transferring sanitary chemicals, filling
printed circuit fabrication. small containers with liquid floor.
Plating Shops • Transferring acids into tanks 10-15 polishes, liquid detergents, etc.
• Transferring nitric, sulfuric, muriatic feet away. • Pumping alkaline cleaning chemicals.
and hydrofluoric acid. • Handling ferric chloride and sodium • Mixing liquid soaps.
• Emptying spent metal finishing acids persulfate for etching.
and alkalies at 32°F to 130°F.
• Emptying liquid nickel sulfate from 55 Pulp and Paper
gallon drums into smaller pails. Grain Processing Manufacturing
• Transferring cyanide zinc @ 90°F • Moving surfactants at 90°F in grain • Pumping sulphuric acid up 8’.
safely and economically. processing. • Transferring ammonia in processing
• Plating solutions at room tempera- pulp and paper.
ture pumped 20 feet across and • Moving ammonia and latex 15’
5 feet up. across plant and up to 10’ in paper
• Transferring phosphoric, nitric and and pulp processing.
sulfuric acids into small tanks.
• Mixing and transferring aluminum
brighteners. Electrical Power
• Emptying copper, cadmium and and Utility Companies
silver cyanide; ferric chloride, • Transferring acids from drums and
copper sulfate, tin lead, ferric Latex and Rubber carboys.
chloride, copper fluoborate and • Transferring styrene across the shop. • Handling 35% hydrazine for electric
nickel sulfamate at 65° to 150°F. • Transferring from drums to mixer in generators.


• Reactivating anodizing solution with water paint manufacture. • Hazardous chemical disposal from 55
sulfuric and chromic acids. • Pumping 20% muriatic acid at 80°F gallon drum to a reactor tank.
• Pumping out hot cleaners for rubber processing.
with alkali.

Photo Processing
Industrial Chemicals • Transferring ammonia thiosulphate
• Packaging acids and alkalies in for photo processing.
bottles. • Pumping ethylene glycol, methanol,
• Pumping acids up to the floor above. ammonium, thyocyanate, NaOH.
• Transferring viscous wool oil from
drum to hoppers. Plus hundreds of other enthusiastic
• Pumping out hot cleaners with alkali. Waste and Water Treatment replies from hospitals, institutions,
• Filling small containers of industrial • Pumping treatment chemicals, caustic laboratories, universities, photo
chemicals from carboys and drums soda, sodium hypochlorite, sodium processors, chemical suppliers,
for retail sales. metabisulfite and sulfuric acid into industrial cleaner packagers, food
• Mixing and transferring hot caustics. reagent tanks. processors, beverage canners,
• Emptying 55 gallon drums of • Pumping ferric chloride for floculation and the manufacturers of mirrors,
hydroflouric acid without hoisting of solids. automotive parts, aerospace
them into 5 gallon containers. components, fiberglass and more.

©COPYRIGHT 2006 MET-PRO CORPORATION, SETHCO DIVISION Sethco Division ® IS A REGISTERED TRADEMARK OF MET-PRO CORPORATION 12-06

Sethco Division
800 Emlen Way, Telford, PA 18969
Tel: 800-645-0500 • Fax: 215-799-0920
Website: www.sethco.com • E-mail: info@sethco.com
West Coast Office: 230 N. Crescent Way, Unit I, Anaheim, CA 92801 • Tel: 714-991-0270 • Fax: 714-991-8107

Potrebbero piacerti anche